INSTEON Refurbished Remote Control Dimmer Switch, Toggle Guide de démarrage rapide

Taper
Guide de démarrage rapide

Ce manuel convient également à

Page 1 of 1
Rev. 07-16-2012
Set button
and
status LED
Installing ToggleLinc (Typical 2-Way Circuit)
Note: For multi-way circuit installation, refer to the Owner’s Manual
1) At the circuit breaker or fuse panel, disable the circuit supplying power to
the switch
2) Remove the faceplate from the existing switch, unscrew the switch and pull
it out from the junction box
3) Disconnect the wires from the switch you are replacing and ensure you
have ½” of bare wire on the ends
4) See Figure 1 to identify and connect the line, load, neutral and ground wires
to the INSTEON device. If the colors of the wires do not match the diagram,
be sure you have identified the wires correctly before connecting them.
Note: Mechanical switches don’t utilize neutral wires, but they are usually
available in the back of the switch box
5) Ensure that all wires are firmly attached and that there is no exposed copper
except for the ground wire
6) Orient ToggleLinc with the Set button at the bottom, gently place it into the
junction box and screw it into place
7) Enable power to the fixture from the circuit breaker or fuse panel
8) Test that ToggleLinc is working properly by turning the light on and off
9) Reinstall the faceplate
Quick Start Guide
ToggleLinc
Dimmer – INSTEON
®
Remote Control
Dimmer Switch
Model: 2466D (600W), Rev 5.0+
Your new ToggleLinc Dimmer Switch allows you to dim and remotely
control any light in your home at the touch of a button.
Limited Warranty INSTEON warrants to original consumer of this product for a period of 2 years from date of purchase, this product will be free from
defects in material and workmanship and will perform in substantial conformity with its Owner's Manual. Warranty shall not apply to defects caused by
misuse or neglect.
U.S. Patent No. 7,345,998, International patents pending © Copyright 2010
INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 1-800-SMARTHOME (800-762-7846)
Preparation
Installation should be performed only by a qualified electrician or a homeowner
who is familiar and comfortable with electrical circuitry. If you have any questions
regarding installation, we suggest consulting an electrician. Software such as
HouseLinc
TM
2 can make INSTEON device setup and management much easier.
If you have any questions regarding setup, contact the INSTEON Support Line.
Tools Needed
Flathead and Phillips screwdrivers
Wire cutter/stripper
Voltage tester to identify wires inside the junction box
Complete Instructions, Troubleshooting and Tech Support
Owner’s Manual: http://www.insteon.com/support
Call: INSTEON Support Line at 800-762-7846
Using ToggleLinc
Tap the toggle up to turn on your light.
Tap the toggle down to turn off your light.
Press and hold the toggle up to brighten your light.
Press and hold the toggle down to dim your light.
Double tap the toggle up to instantly turn on your light.
Double tap
the toggle down to instantly turn off your light.
Figure 1
ETL/UL Warning
CAUTION - To reduce the risk of overheating and possible damage to other equipment do not install to control a receptacle, a motor-operated appliance, a fluorescent lighting fixture,
or a transformer-supplied appliance.
Gradateurs commandant une lampe a filament de tungstene afin de reduire le risqué de surchauffe et la possibilite d’endommagement a d’autres materiels, ne pas installer pour commader une
prise, un appareil a moteur, une lampe fluorescente ou un appareil alimente par un transformateur.
Using ToggleLinc as an INSTEON Controller
1) Press and hold the ToggleLinc’s Set button until the unit beeps (about 3
seconds)
Status LED will begin blinking
You will have 4 minutes to complete the next step
2) Select the INSTEON device you’d like to control and activate its linking mode
ToggleLinc will double-beep
Status LED will stop blinking and turn on solid.
3) Confirm link by pressing ToggleLinc toggle up and down
The load connected to ToggleLinc should respond appropriately
Using ToggleLinc as an INSTEON Responder
1) Select an INSTEON-compatible controller and activate its linking mode
You will have 4 minutes to complete the next step
2) Press and hold the ToggleLinc Set button until the unit double-beeps (about
3 seconds)
Status LED will flash and turn on solid
3) Confirm the link by tapping the linked controller button on and off
The load connected to ToggleLinc should respond appropriately