4
68-2294-50 Rev. B
11 15
Extron Headquarters
+1.800.633.9876 (Inside USA/Canada Only)
Extron USA - West Extron USA - East
+1.714.491.1500 +1.919.850.1000
+1.714.491.1517 FAX +1.919.850.1001 FAX
Extron Europe
+800.3987.6673
(Inside Europe Only)
+31.33.453.4040
+31.33.453.4050 FAX
Extron Asia
+65.6383.4400
+65.6383.4664 FAX
Extron Japan
+81.3.3511.7655
+81.3.3511.7656 FAX
Extron China
+86.21.3760.1568
+86.21.3760.1566 FAX
Extron Middle East
+971.4.299.1800
+971.4.299.1880 FAX
Extron Korea
+82.2.3444.1571
+82.2.3444.1575 FAX
Extron India
1800.3070.3777
(Inside India Only)
+91.80.3055.3777
+91.80.3055.3737 FAX
© 2015 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com
TLP Pro 1220TG and TLP Pro 1520TG • Setup Guide (Continued)
B
USB connectors (see figure 5 on the previous page) — for peripheral controls.
C
Rear status light (see figure 5) — an LED light bar that can be programmed to provide system feedback.
D
HDMI input (see figure 5) — for alternative video input.
E
XTP/LAN/PoE input (see figure 5) — is in the top of the recessed area. Use Cat 5e or greater cable terminated with an RJ‑45
connector. Extron recommends using XTP DTP 24 SF/UTP cable for the best performance. At a minimum, Extron recommends
24 AWG, solid conductor, STP cable with a minimum bandwidth of 400 MHz.
z If you are using a 12 VDC power supply (see figure 5,
A
) connect the touchpanel
directly to an XTP source or to a LAN.
z If you are using a PoE+ power injector (not provided), connect the cables as
shown in the gure to the right. This gure shows the Extron PI 140 power injector
(recommended by Extron).
An Extron IP Link Pro control processor must also be connected to the same network as
the TouchLink Pro touchpanel.
F
Audio output (see figure 5) — for use with headphones or assistive listening devices.
G
Menu button (see figure 5) — activates the setup menu and calibration screen (see
below).
H
Reset button (see figure 5) — pressing the reset button allows the unit to be reset in any of three different modes.
I
Reset LED (see figure 5) — provides feedback about the reset status when the user presses the reset button.
J
VESA mounting holes (4) (see figure 5) — for use with D‑type VESA mounting kits with the 100 x 100 mm mounting pattern.
K
Base attachment hinge (2) (see figure 5) — each hinge secures the touchpanel to the base with two screws.
Reset Modes Summary
The TLP Pro 1220TG and TLP Pro 1520TG offer the following reset modes. For full information about the modes, see the
TLPPro 1220 Series and TLPPro 1520 Series User Guide.
• Use factory firmware:
Press and hold the Reset button (figure 5,
H
) while applying power to the unit. Use this mode
to replace rmware in the event of rmware failure.
• Reset All IP Settings:
Press and hold the Reset button for 6 seconds. After the Reset LED (figure5,
I
) blinks twice,
release and momentarily press the Reset button. Use this mode to reset all network settings
without affecting user‑loaded les.
• Reset to Factory Defaults:
Press and hold the Reset button for 9 seconds. After the Reset LED blinks three times, release
and momentarily press the Reset button. Use this mode to return the interface to factory
default settings.
Setup Menu
Press the Menu button (figure 5,
G
) to open the setup menu. Select
any of the ve available screens (Status, Network, Display, Audio,
Input and Advanced) by pressing the appropriate button in the
navigation bar at the top of the screen (for more information, see the
TLPPro 1220 Series and TLP Pro 1520 Series User Guide).
Figure 6 shows the setup menu for the TLP Pro 1220TG. The setup
menu for the TLP Pro 1520TG is very similar.
Press the Menu button for at least 3 seconds to open the calibration
screen. Follow the on‑screen instructions.
Figure 6. Setup Menu: Status page for TLP Pro 1220TG
Info
Model: TLP Pro 1220TG
Part Number:60-1341-02
Firmware
Version:
1.02.0000.b003
PoE: Active
Network
IP Address:
DHCP:
Host Name:
Off
192.168.254.251
TLI-AB-CD-EF
Display
Resolution:
Project:
Sleep Timer:
1280x800
1280x800
5 Minutes
Audio
Master Volume:
Master Mute: Off
100
Input
HDMI: No Signal
Status
Display
Audio
Advanced
Exit
Network
Input
Advanced
Controller IP: 192.168.254.250
Project Size: 1/197 MB
Bootloader
Version:
1.03.0000
XTP: 1280x720
HDCP
100-240V~50/60 Hz
1.1A MAX
INPUT OUTPUT
POWERED TLP
LAN
To Network or
To a TLP Pro
on PI 140