Attendance Configuration
3
2
Access Control System Configuration
User Management
1
Note: The external power supply and the access control terminal should use the same GND cable.
Manage User: In the New (New User) interface, enter the
new user ID No., the user name, the card No. Register the
fingerprint, set the password, select the department, set the
user permission, select schedule template, set the authenca-
on mode and set the duress card. Save the parameters to
confirm adding.
ACS System Configuration:
In the ACS Parameters Seng interface, configure the terminal authencaon mode, the sub reader authencaon
mode, the door magnec status, the lock acon me, the door-open meout alarm, and the maximum mes for
authencaon.
Holiday Group Configuration:
In New (New Holiday Group) interface, enter a new holiday group name. Select New ACS Holiday and enter the holiday
No., the holiday name, the holiday start me and the holiday end me. Save the parameters to confirm adding.
Week Plan Configuration:
In the Week Plan menu, select New (New Week Plan) to configure the week plan parameters, including the No., the
name, the week plan me and the corresponding periods. Save the parameters to confirm adding.
Schedule Template Configuration:
In the Schedule Template menu, select New (New Schedule Template) to configure the schedule template parameters,
including the template No., the template name, the week plan and the holiday group. Save the parameters to confirm
adding.
Configure the shi via the device. You are able to schedule shi
by department or by individual depending on the user property.
The working flows are as follows:
Scheduling Shift by Department: Add User (See Step 1) -
Edit Department - Configure Shi - Add Holiday - Configure Shi
Schedule (by Department).
Edit Department: Select a department to edit in the department list. Select “Edit”and edit the department name, shi type and shi name. Save the parameters to confirm eding.
Configure Shift
Normal Shi: In the Normal Shi interface, configure the aendance rule, the normal shi aendance. Save the parameters to confirm seng.
Man-Hour Shi: In the Man-Hour Shi interface, configure the man-hour shi parameters. Save the parameters to confirm seng.
Add Holiday
In the New (New Holiday) interface, enter the holiday No, the holiday name, the holiday start me and the holiday end me. Save the parameters to confirm adding.
Configure Shift Schedule
Schedule Shi by Department: Select a department to configure in the By Dept. (Schedule by Department) interface. Configure the shi, the start date, the end date and the holiday.
Save the parameters to confirm configuraon.
Schedule Shi by Individual: Select New Individual Shi in the By Indiv. (Schedule by Individual) interface. Select a person to schedule in the New Individual Shi interface. Configure
the shi, the schedule start date and the end date. Save the parameters to confirm eding.
User Management
ACS Configuraon
Aendance
Configuraon
Attendance Report
Plug the USB disk in the device. In Report interface of Aendance interface, select a table type to export. Press the OK key to export the aendance report to the USB disk.
The device will automacally check the USB disk memory. If there is no enough space for exporng, a prompt will be displayed. You are able to configure the record over threshold
prompt and record delete funcon in the System interface.
Record over Threshold Pop up Prompt (%): If the aendance record memory reaches the configured value, the system will pop up a prompt to remind you. If configure the
threshold to 99%, the system will pop up a prompt to remind you to delete the aendance data when the capacity reaches the threshold. The available value: 1 to 99.
Record Delete: When the funcon is enabled, the terminal will delete the first 3000 aendance records when the memory is full, in order to save the new aendance records. By
default, the funcon is enabled. See Secon 5.2 Aendance Record Delete Rule in the User Manual of Fingerprint Time Aendance Terminal.
Scheduling Shift by Individual: Add User (See Step 1) - Configure Shi - Add Holiday - Configure Shi Schedule (by Individual).
User Management, Access Control System Configuraon and
Aendance Configuraon are three main parts of the Access
Control Terminal.
Regulatory Information This product and - if applicable - the supplied accessories too are marked with "CE"
and comply therefore with the applicable harmonized European standards listed
under the RE Direcve 2014/53/EU, the EMC Direcve 2014/30/EU, the RoHS
Direcve 2011/65/EU.
2012/19/EU (WEEE direcve): Products marked with this symbol cannot be
disposed of as unsorted municipal waste in the European Union. For proper
recycling, return this product to your local supplier upon the purchase of
equivalent new equipment, or dispose of it at designated collecon points. For
more informaon see: www.recyclethis.info
2006/66/EC (baery direcve): This product contains a baery that cannot be
disposed of as unsorted municipal waste in the European Union. See the product
documentaon for specific baery informaon. The baery is marked with this
symbol, which may include leering to indicate cadmium (Cd), lead (Pb), or
mercury (Hg). For proper recycling, return the baery to your supplier or to a
designated collecon point. For more informaon see: www.recyclethis.info
Industry Canada ICES-003 Compliance
This device meets the CAN ICES-3 (B)/NMB-3(B) standards requirements.
This device complies with Industry Canada licence-exempt RSS standard(s). Operaon is subject to the following two condions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operaon of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radioexempts de licence. L'exploitaon est autorisée aux deux
condions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'ulisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est suscepble d'en compromere le fonconnement.
Under Industry Canada regulaons, this radio transmier may only operate using an antenna of a type and maximum (or lesser) gain approved for the
transmier by Industry Canada. To reduce potenal radio interference to other users, the antenna type and its gain should be so chosen that the equivalent
isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communicaon.
Conformément à la réglementaon d'Industrie Canada, le présent émeeur radio peut
fonconner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émeeur par Industrie Canada. Dans le but de réduire les risques
de brouillage radioélectrique à l'intenon des autres ulisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée
équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communicaon sasfaisante.
This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body.
Cet équipement doit être installé et ulisé à une distance minimale de 20 cm entre le radiateur et votre corps.
—Consult the dealer or an experienced radio/TV technician for
help.
This equipment should be installed and operated with a
minimum distance 20cm between the radiator and your body.
FCC Conditions
This device complies with part 15 of the FCC Rules. Operaon is
subject to the following two condions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including
interference that may cause undesired operaon.
EU Conformity Statement
FCC Information
Please take aenon that changes or modificaon not expressly approved by the
party responsible for compliance could void the user’s authority to operate the
equipment.
FCC compliance: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protecon against harmful interference in a
residenal installaon. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instrucons,
may cause harmful interference to radio communicaons. However, there is no
guarantee that interference will not occur in a parcular installaon. If this
equipment does cause harmful interference to radio or television recepon, which
can be determined by turning the equipment off and on, the user is encouraged to
correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separaon between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Use only power supplies listed in the user instrucons:
Model Manufacturer Standard
DSA-12PFT-12FUK 120100
DSA-12PFT-12FAU 120100
DSA-12PFT-12FIN 120100
DSA-12PFT-12FUS 120100
DSA-12PFT-12 FBZ 120100
Dee Van Enterprise Co., Ltd. BS
Dee Van Enterprise Co., Ltd.
Dee Van Enterprise Co., Ltd.
Dee Van Enterprise Co., Ltd.
Dee Van Enterprise Co., Ltd.
AS
NBR
IEC
IS
Door Magnec
RS-485
(Reserved)
D7
D6
D5
D4
D3
D2
D1
D8
View License:
You can view the device License via the website: hp://opensource.hikvision.com/Home/List?id=46
Scan the QR code to get the user
manual for detailed informaon.
Note that mobile data charges may
apply if Wi-Fi is unavailable.
Device Wiring
4Configuration
5