Once the boot-up sequence is complete, the amplier takes more time to sync with the Dante network and begin the playback of
streamed content. The front panel LED lights green after approximately 20 seconds.
ATTENTION:
• The amplier must be powered on last.
• L’amplicateur doit être mis sous tension en dernier.
Step 7 — Checking LEDs
Check the Limiter/Protect and Signal LEDs on the front and rear panels to see if any problems are encountered (see “Front Panel
Features and Troubleshooting” in the NetPA U 2002 SB User Guide for more information).
Double-check the correct load is connected and properly wired to the rear panel connections (see Speaker Wiring on page 3 for
more information).
Step 8 — DSP Configurator Software Installation
There are no hardware controls for the NetPA U 2002 SB. Conguration is done using Extron DSP Congurator software and
control is performed using SIS commands. To learn about full computer requirements, see the DSP Congurator product page on
www.extron.com.
Download DSP Configurator from the Extron Website
1. From the Extron home page (www.extron.com), click the Download tab to open the Download page.
2. Under Software (located on the left side of the page), select DSP Congurator Software. The DSP Configurator
Software product page opens.
3. Click the Download button and follow the on-screen instructions.
NOTE: An Extron Insider account is required to download DSP Configurator.
Step 9 — NetPA U 2002 SB Configuration
When power is connected to the unit and the rest of the audio system, audio output can be easily configured for any listening
environment via the DSP Configurator. The following steps detail how to configure a NetPA U 2002 SB amplifier.
Configure the NetPA U 2002 SB Amplifier
1. Ensure the control computer is connected to either the AT port, RS-232 port, or the rear panel USB conguration port.
2. Start the DSP Congurator software. From the splash screen drop-down list, select NetPA U 2002 SB. Click OK. The main
workspace opens.
3. The software starts in Emulate mode:
a. To create a conguration le ofine and then upload that conguration to a NetPA U 2002 SB unit at a later time, remain
in Emulate mode and save the conguration le.
b. To upload a conguration to the NetPA U 2002 SB unit or download the current conguration from the unit, enter Live
mode. When in Live mode, changes made in DSP Congurator immediately affect the connected NetPA U 2002 SB. To
enter Live mode, click Live at the top of the DSP Congurator workspace, or select Tools > Connect to Device, or
press <F6> on the keyboard.
NOTE: When Live mode is selected, a connection dialog box appears. Select the desired connection type and
follow the on-screen prompts (see the NetPA U 2002 SB User Guide for more information on connecting live to a
device).
The main workspace provides access to mix matrices, gain
blocks, and DSP processors for conguring a NetPA U 2002
SB. It also provides a menu bar across the top with additional
conguration tools. For more information on using the DSP
Congurator, see the “DSP Congurator” section of the
NetPA U 2002 SB User Guide, or the DSP Configurator Help File
that can be accessed by selecting Help > Contents or
pressing <F1>. Most dialog boxes within DSP Congurator
contain a Help button ( ) in the top right corner. Click this
button to open the help le topic for that particular dialog box.