Extron XPA Ultra Series Manuel utilisateur

Catégorie
Amplificateurs audio
Taper
Manuel utilisateur
User Guide
XPA Ultra Series:
Audio Products
Half-Rack Audio Power Amplifiers
68-3149-01 Rev. C
02 20
XPA U 758, XPA U 358, XPA U 358-70V, XPA U 358-100V, XPA U 358C-70V, XPA U 358C-100V
XPA U 1004, XPA U 1004-70V, XPA U 1004-100V, XPA U 1004C-70V, XPA U 1004C-100V,
XPA U 1002, XPA U 1002-70V, XPA U 1002-100V
Safety Instructions
Safety Instructions • English
WARNING: This symbol, , when used on the product, is intended to
alert the user of the presence of uninsulated dangerous voltage within the
product’s enclosure that may present a risk of electric shock.
ATTENTION: This symbol, , when used on the product, is intended
to alert the user of important operating and maintenance (servicing)
instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron
website, www.extron.com.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer darauf
aufmerksam machen, dass im Inneren des Gehäuses dieses Produktes
gefährliche Spannungen herrschen, die nicht isoliert sind und die einen
elektrischen Schlag verursachen können.
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in
der im Lieferumfang enthaltenen Dokumentation besonders wichtige
Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,
EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in
den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer
68-290-01) auf der Extron-Website, www.extron.com.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del
producto, lo que puede representar un riesgo de descarga eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto, avisa
al usuario de la presencia de importantes instrucciones de uso y
mantenimiento recogidas en la documentación proporcionada con el
equipo.
Para obtener información sobre directrices de seguridad, cumplimiento
de normativas, compatibilidad electromagnética, accesibilidad y temas
relacionados, consulte la Guía de cumplimiento de normativas y seguridad
de Extron, referencia 68-290-01, en el sitio Web de Extron, www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT : Ce pictogramme, , lorsqu’il est utilisé sur le
produit, signale à l’utilisateur la présence à l’intérieur du boîtier du
produit d’une tension électrique dangereuse susceptible de provoquer
un choc électrique.
ATTENTION : Ce pictogramme, , lorsqu’il est utilisé sur le produit,
signale à l’utilisateur des instructions d’utilisation ou de maintenance
importantes qui se trouvent dans la documentation fournie avec le
matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la
réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets
connexes, lisez les informations de sécurité et de conformité Extron, réf.
68-290-01, sur le site Extron, www.extron.com.
Istruzioni di sicurezza • Italiano
AVVERTENZA: Il simbolo, , se usato sul prodotto, serve ad
avvertire l’utente della presenza di tensione non isolata pericolosa
all’interno del contenitore del prodotto che può costituire un rischio di
scosse elettriche.
ATTENTZIONE: Il simbolo, , se usato sul prodotto, serve ad avvertire
l’utente della presenza di importanti istruzioni di funzionamento e
manutenzione nella documentazione fornita con l’apparecchio.
Per informazioni su parametri di sicurezza, conformità alle normative,
compatibilità EMI/EMF, accessibilità e argomenti simili, fare riferimento
alla Guida alla conformità normativa e di sicurezza di Extron, cod. articolo
68-290-01, sul sito web di Extron, www.extron.com.
Instrukcje bezpieczeństwa • Polska
OSTRZEŻENIE: Ten symbol, , gdy używany na produkt, ma na celu
poinformować użytkownika o obecności izolowanego i niebezpiecznego
napięcia wewnątrz obudowy produktu, który może stanowić zagrożenie
porażenia prądem elektrycznym.
UWAGI: Ten symbol, , gdy używany na produkt, jest przeznaczony do
ostrzegania użytkownika ważne operacyjne oraz instrukcje konserwacji
(obsługi) w literaturze, wyposażone w sprzęt.
Informacji na temat wytycznych w sprawie bezpieczeństwa, regulacji
wzajemnej zgodności, zgodność EMI/EMF, dostępności i Tematy pokrewne,
zobacz Extron bezpieczeństwa i regulacyjnego zgodności przewodnik, część
numer 68-290-01, na stronie internetowej Extron, www.extron.com.
Инструкция по технике безопасности Русский
ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан
на продукте, предупреждает пользователя о наличии
неизолированного опасного напряжения внутри корпуса
продукта, которое может привести к поражению
электрическим током.
ВНИМАНИЕ: Данный символ, , если указан на продукте,
предупреждает пользователя о наличии важных инструкций
по эксплуатации и обслуживанию в руководстве,
прилагаемом к данному оборудованию.
Для получения информации о правилах техники безопасности,
соблюдении нормативных требований, электромагнитной
совместимости (ЭМП/ЭДС), возможности доступа и других
вопросах см. руководство по безопасности и соблюдению
нормативных требований Extron на сайте Extron: ,
www.extron.com, номер по каталогу - 68-290-01.
安全说明 简体中文
警告 产品上的个标志意在警告用户该产品机壳内有暴露的危险
险。
注意 产品上的这个标志意在提示用户设备随附的用户手册中有
重要的操作和维护(维修)说明。
关于我们产品的安全指南、遵循的规范、EMI/EMF 的兼容性、无障碍
使用的特性等相关内容,敬请访问 Extron 网站 , www.extron.com,参见
Extron 安全规范指南,产品编号 68-290-01
안전 지침 • 한국어
경고: 이 기호 가 제품에 사용될 경우, 제품의 인클로저 내에 있는
접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을
경고합니다.
주의: 이 기호 가 제품에 사용될 경우, 장비와 함께 제공된 책자에 나와
있는 주요 운영 및 유지보수(정비) 지침을 경고합니다.
안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련 항목에
대한 자세한 내용은 Extron 웹 사이트(www.extron.com)의 Extron 안전 및
규제 준수 안내서, 68-290-01 조항을 참조하십시오.
安全記事 • 繁體中文
警告: 若產品上使用此符號是為了提醒使用者產品機殼內存在著
可能會導致觸電之風險的未絕緣危險電壓。
注意 產品使用此符號,是為提醒使用設備隨附手冊中有
護( )説
有關安全性指導方法規遵EMI/EMF 相取範圍和相關主題的詳細資
訊,請瀏覽 Extron 網站www.extron.com然後參閱《Extron 安全性與法規
守手冊準則編號 68-290-01。
安全上の注意 日本語
警告: この が製品上に表示されている場合は、筐体内に絶縁され
いない高電圧が流れ、電の危険があるこていま
意:この 製品上に表示されている場合は、の取扱明書に
されている重要作と保()のについてユーザー
を喚起するものです
安全上のご注意、法規厳守、EMI/EMF適合性、その他の関連項目
スト イト www.extron.com よ り Extron Safety
and Regulatory Compliance Guide』 ( P/N 68-290-01) をご覧ださい。
Copyright
© 2018-2020 Extron Electronics. All rights reserved. www.extron.com
Trademarks
All trademarks mentioned in this guide are the properties of their respective owners.
The following registered trademarks (
®
), registered service marks (
SM
), and trademarks (
TM
) are the property of RGBSystems, Inc.
ExtronElectronics (see the current list of trademarks on the Terms of Use page at www.extron.com):
Registered Trademarks
(
®
)
Extron, Cable Cubby, ControlScript, CrossPoint, DTP, eBUS, EDID Manager, EDID Minder, Flat Field, FlexOS, Glitch Free. Global Configurator,
GlobalScripter, GlobalViewer, Hideaway, HyperLane, IPIntercom, IPLink, KeyMinder, LinkLicense, LockIt, MediaLink, MediaPort, NetPA,
PlenumVault, PoleVault, PowerCage, PURE3, Quantum, ShareLink, Show Me, SoundField, SpeedMount, SpeedSwitch, StudioStation,
SystemINTEGRATOR, TeamWork, TouchLink, V-Lock, VideoLounge, VN-Matrix, VoiceLift, WallVault, WindoWall, XTP, XTPSystems, and ZipClip
Registered Service Mark
(SM)
: S3 Service Support Solutions
Trademarks
(
)
AAP, AFL (Accu-RateFrameLock), ADSP(Advanced Digital Sync Processing), Auto-Image, AVEdge, CableCover, CDRS(ClassD
Ripple Suppression), Codec Connect, DDSP(Digital Display Sync Processing), DMI (DynamicMotionInterpolation), DriverConfigurator,
DSPConfigurator, DSVP(Digital Sync Validation Processing), eLink, EQIP, Everlast, FastBite, FOX, FOXBOX, IP Intercom HelpDesk, MAAP,
MicroDigital, Opti-Torque, PendantConnect, ProDSP, QS-FPC(QuickSwitch Front Panel Controller), RoomAgent, Scope-Trigger, SIS,
SimpleInstructionSet, Skew-Free, SpeedNav, Triple-Action Switching, True4K, Trade 8K, Vector™ 4K , WebShare, XTRA, and ZipCaddy
FCC Class B Notice
NOTE: This device complies with part 15 of the FCC rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2) This
device must accept any interference received, including interference that may cause
undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part15 of the FCC rules. These limits provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. There is no guarantee that interference will not
occur. If this equipment does cause interference to radio or television reception, which can
be determined by turning the equipment off and on, you are encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
In order to maintain compliance with FCC regulations, shielded cables must be used with this
equipment. Operation with non-approved equipment or unshielded cables is likely to result in
interference to radio and TV reception. The user is cautioned that changes and modifications
made to the equipment without the approval of the manufacturer could void the user’s authority
to operate this equipment.
NOTE: For more information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics see the Extron Safety and Regulatory
Compliance Guide on the Extron website.
Conventions Used in this Guide
Notifications
The following notifications are used in this guide:
WARNING: Potential risk of severe injury or death.
AVERTISSEMENT : Risque potentiel de blessure grave ou de mort.
ATTENTION:
Risk of property damage.
Risque de dommages matériels.
NOTE: A note draws attention to important information.
Specifications Availability
Product specifications are available on the Extron website, www.extron.com.
Extron Glossary of Terms
A glossary of terms is available at http://www.extron.com/technology/glossary.aspx.
viXPA Ultra Series Power Amplifiers • Contents
Contents
Introduction ...............................................1
About this Manual................................................ 1
Features .............................................................. 1
Installation .................................................4
Application Examples .......................................... 4
Mounting the XPA Ultra Series Amplifiers ............. 6
Tabletop Use ................................................... 6
UL Guidelines for Rack Mounting ..................... 6
Rack Mounting ................................................ 7
Rack Mounting Ventilation
Recommendations ....................................... 10
Flexible Conduit Adapter Kit Installation ............. 11
Operation .................................................15
Front Panel Features and Operation .................. 15
Rear Panel Features and Operation ................... 16
Bridged Mono Output (8 ohm/4 ohm
outputs only) ................................................. 19
Troubleshooting ................................................. 20
Amplifier Fails to Exit Standby Mode
Promptly ....................................................... 20
Amplifier Enters Standby Mode Too Early ....... 21
Limiter/Protect LED Warning Indicators.......... 21
Over Temp Indicator LED ............................... 21
XPA Ultra Series Power Amplifiers • Introduction 1
Introduction
About this Guide
This guide contains information about the Extron XPA Ultra Series of power amplifiers:
XPA U 758 eight channel low impedance power amplifier
XPA U 358 eight channel low impedance power amplifier
XPA U 358-70V eight channel 70 volt power amplifier
XPA U 358-100V eight channel 70 volt power amplifier
XPA U 358C-70V eight channel combination low impedance and 70 volt power amplifier
XPA U 358C-100V eight channel combination low impedance and 70 volt power
amplifier
XPA U 1004 four channel low impedance power amplifier
XPA U 1004-70V four channel 70 volt power amplifier
XPA U 1004-100V four channel 100 volt power amplifier
XPA U 1004C-70V four channel combination low impedance and 70 volt power
amplifier
XPA U 1004C-100V four channel combination low impedance and 100 volt power
amplifier
XPA U 1002 two channel low impedance power amplifier
XPA U 1002-70V two channel 70 volt power amplifier
XPA U 1002-100V two channel 100 volt power amplifier
Terms Used in this Guide
The terms “amplifier” and “power amplifier” are used interchangeably in this manual to refer
to all of the XPA Ultra models.
Features
Output Power
XPA U 758 models — 75 watts rms output power per channel, 8 ohms, all
channels driven; 50 watts per channel, 4 ohms, all channels driven.
XPA U 358 models — 35 watts rms output power per channel, all channels driven.
XPA U 1004 models — 100 watts rms output power per channel, all channels
driven.
XPA U 1002 models — 100 watts rms output power per channel, all channels
driven.
XPA Ultra Series Power Amplifiers • Introduction 2
ENERGY STAR
®
qualified amplifiers — The XPA Ultra Series are ENERGY STAR
qualified amplifiers and energy efficient products that conserve energy and reduce
costs.
Extron Patented CDRS - Class D Ripple Suppression — CDRS is an Extron
Patented technology that provides a smooth, clean audio waveform and an
improvement in signal fidelity over conventional Class D amplifier designs. CDRS
eliminates the high frequency switching ripple characteristics of Class D amplifiers,
a source of RF emissions which can interfere with sensitive AV equipment such as
wireless microphones.
Convection cooled, fanless operation - can be stacked without extra rack
space for ventilation — The XPA Ultra Series amplifiers do not require internal fans
or vents for cooling, ensuring quiet, reliable operation. They generate substantially less
heat than conventional power amplifiers, making them ideal for rack-mount applications
where space is at a premium.
Eight channels (XPA U 358 and 758 models), four channels (XPA U 1004
models), or two channels (XPA U 1002 models) in a 1U, half rack width
enclosure - single and dual rack mount hardware included — The channel density
of the XPA Ultra Series amplifiers reduce rack space requirements for many installations.
The included single and side by side rack mount hardware simplifies planning and saves
cost.
Defeatable auto-standby with fast wake up — The XPA Ultra Series amplifiers
meet ENERGY STAR qualification requirements with an auto-standby feature that
automatically places the amplifier into standby after 25 minutes of inactivity, dramatically
reducing power consumption. The XPA Ultra Series amplifiers quickly return to full
power status in less than 100 ms upon signal detection, with minimal inrush current.
Auto-standby can be disabled if required.
UL 2043 plenum rated when used with optional Flexible Conduit Adapter
Kit — The XPA Ultra Series amplifiers meet UL 2043 for smoke and heat release for
installation within a plenum airspace above a drop ceiling when used with the optional
Flexible Conduit Adapter Kit. Above-the-ceiling placement conceals the amplifier to
prevent theft, and is convenient for installing equipment when space inside the room is
limited.
Professional grade signal-to-noise and THD+N performance — The
XPAUltraSeries amplifiers deliver professional grade performance, featuring 100 dB
signal-to-noise ratio and THD+N of less than 0.1%.
Ultra low inrush current at power up - no need for power sequencing
Allows multiple XPA Ultra Series amplifiers to be powered on simultaneously without
overloading power circuits. This eliminates the need for power sequencing.
Power factor correction - removes harmonic content on AC line — The
XPAUltraSeries amplifiers feature power factor correction technology that smooths out
the high peak currents of the current draw of the amplifiers, minimizing the presence of
high frequency harmonics on the AC power line, preventing audible artifacts from being
transmitted to other audio equipment in the system.
Rear panel recessed, detented level controls — Provides attenuation of input
signals for adjusting audio system gain staging. These controls are located on the rear
panel to prevent tampering with level adjustments. Laser etched markings provide
enhanced visibility of settings for ease of configuration.
Automatic clip limiter — Detects actual onset of clipping. Gain is automatically
reduced without audible artifacts to protect speakers from clipping distortion.
Multiple protection circuits — Active during output shorts, thermal overload, or DC
faults to prevent damage to the amplifier and speakers.
XPA Ultra Series Power Amplifiers • Introduction 3
Remote standby port — Enables the XPA Ultra Series amplifiers to be remotely
powered down when not in use, reducing operating cost.
High pass filter for high impedance models — This selectable filter, available on the
XPA Ultra Series high impedance models, rolls off frequencies below 80 Hz to prevent
saturation of speaker transformers.
5 mm screw-lock captive screw speaker connectors — Enable simple, secure
connections with 22 to 12 AWG speaker cables.
Front and rear-mounted signal and protection indication LEDs — Provide
convenient indication of input signal presence and protection circuit activation from both
sides of an equipment rack.
Front panel over-temperature LED — Provides visual indication that the amplifier
temperature has exceeded the optimal value, well in advance of the onset of thermal
protection circuitry.
Internal Extron Everlast Power Supply — Provides worldwide power compatibility,
with high-demonstrated reliability and low power consumption for reduced operating
cost.
Extron Everlast Power Supply is covered by a 7-year parts and labor warranty.
XPA Ultra Series Power Amplifiers • Installation 4
Installation
This section discusses how to install the XPA Ultra Series of audio power amplifiers. Topics
covered include:
Application Examples
Mounting the XPA Ultra Series Amplifiers
Flexible Conduit Adapter Kit Installation
Application Examples
The following illustrations are application examples for the XPA Ultra Series power amplifiers.
AudioAudio
Ethernet
Audio
Display
DMP EXP
CATx Cable up to
230' (70 m)
HDMI
Ethernet
Ethernet
Ethernet
RS-232
Extron
DMP 128 Plus C V AT
Digital Matrix Processor
Extron
DTP HDMI 4K 230 Rx
Receiver
Extron
DTP CrossPoint 82 4K IPCP SA
Scaling Presentation
Matrix Switcher
CONFIG
DTP CROSSPOINT 4K SERIES
DIGITAL PRESENTATION SWITCHER
CONTROL I/O
AUDIO
VIDEO
LOGO
SELECT
ENTER PRESET
VIEW
ESC
1
2
3
4
1
2
3
4
5
6
7
8
MIC VOLUME VOLUME
INPUTS
OUTPUTS
eBUS
COM
112
12 2334
12
34
IR/S I/O
RELAYS
SLIMIT
OVER
RTS
CTS
Tx
Rx
HDMI
DIGITAL MATRIX PROCESSOR
CONFIG
CLIP
EXP LANUSB
SIGNAL
CLIP
SIGNAL
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 89 10 11 12
ACTIVITY
INPUTS OUTPUTS
DMP 128 Plus
P
H
U
S
P
H
U
S
P
H
U
S
P
H
U
S
P
H
U
S
P
H
U
S
P
H
U
S
P
H
U
S
Table
Microphones
Table
Microphones
Audio
Extron
XPA U 358
Power Amplifer
Extron
SF 3C LP
Ceiling Speakers
Extron
TLP Pro 720C
Cable Cubby
TouchLink Pro
Touchpanel
AudioAudio
Ethernet/PoE
Extron
Help
System
Off
Display
Room
Control
Off
Mute
Screen
Lighting
December 15, 2013 - 7:58 AM
Audio
Control
Volume
Mute
Tuner
1 2 3
VCRLaptop PC DVD
Doc
Cam
Tuner
On
Channel
Last
Presets
More
Presets
321
654
987
Enter
0
AV LAN
Conference Room
DTP HDMI 230 Rx
OVER DTP
RS-232
IR
Tx Rx Tx RxG
XPA U 358 SERIES
LIMITER/PROTECT
SIGNAL
8
OVER
TEMP
7654321
POWER AMPLIFIERS
AV LAN
LAN
VoIP
AV LAN
AV Sources
Figure 1. XPA U 358 Application Example
1 XPA U 358 Application Diagram
XPA Ultra Series Power Amplifiers • Installation 5
Ethernet
Ethernet
AV LAN
Ethernet
LAN
VoIP
Extron
XPA U 358-70V
Power Amplifer
Extron
SF 3CT LP
Ceiling Speaker
(Zone A1)
(Zone A3)
(Zone A2)
Extron
TLP Pro 725M
TouchLink Pro
Touchpanel
DMP EXP
AudioAudio
Ethernet/PoE
Ethernet
Ethernet/PoE
HDMI
Extron
DMP 128 Plus C V AT
Digital Matrix Processor
Extron
DTP CrossPoint 84 4K IPCP SA
Scaling Presentation
Matrix Switcher
Extron
SF 3CT LP
Ceiling Speaker
(Zone A4)
Extron
SF 3CT LP
Ceiling Speaker
DIGITAL MATRIX PROCESSOR
CONFIG
CLIP
EXP LAN USB
SIGNAL
CLIP
SIGNAL
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 89 10 11 12
ACTIVITY
INPUTS OUTPUTS
DMP 128 Plus
AV LAN
AV LAN
Room A
AV Sources
Lectern
Extron
SF 3CT LP
Ceiling Speaker
(Zone B1)
(Zone B3)
(Zone B2)
Extron
SF 3CT LP
Ceiling Speaker
(Zone B4)
Extron
SF 3CT LP
Ceiling Speaker
AV LAN
Room B
Lectern
CONFIG
DTP CROSSPOINT 4K SERIES
DIGITAL PRESENTATION SWITCHER
CONTROL I/O
AUDIO
VIDEO
LOGO
SELECT
ENTER PRESET
VIEW
ESC
1
2
3
4
1
2
3
4
5
6
7
8
MIC VOLUME VOLUME
INPUTS
OUTPUTS
eBUS
COM
112
12 2334
12
34
IR/S I/O
RELAYS
SLIMIT
OVER
RTS
CTS
Tx
Rx
Microphones
mute select
audio
menu
select ready
sync
power
mute select
audio
menu
selectready
sync
power
Wireless
Microphone
Syst
em
XPA U 358 SERIES
LIMITER/PROTECT
SIGNAL
8
OVER
TEMP
7654321
POWER AMPLIFIERS
Extron
TLP Pro 725M
TouchLink Pro
Touchpanel
Figure 2. XPA U 358-70V Application Examples
2 XPA U 358 70V Application Diagram
XPA Ultra Series Power Amplifiers • Installation 6
Mounting the XPA Ultra Series Amplifiers
The XPA Ultra Series amplifiers can be mounted in a rack using included rack ears, set on a
table, mounted on a rack shelf, or mounted in the plenum space above a ceiling-mounted
projector. Additionally, two XPA Ultra Series amplifiers can be connected using the included
bridging plate to create a full rack width unit.
Tabletop Use
Four self-adhesive rubber feet are included with the audio amplifier.
For tabletop use, attach one foot at each corner on the bottom side of the amplifier and
place the unit in the desired location.
UL Guidelines for Rack Mounting
The following Underwriters Laboratories (UL) guidelines pertain to the installation of the
equipment in a rack.
1. Elevated operating ambient — If installed in a closed or multi-unit rack assembly,
the operating ambient temperature of the rack environment may be greater than room
ambient. Therefore, consider installing the equipment in an environment compatible
with the maximum ambient temperature specified by the manufacturer [Tma = +32 to
+122°F (0 to +50 °C)].
2. Reduced air flow — Installation of the equipment in a rack should be such that the
amount of air flow required for safe operation of the equipment is not compromised.
3. Mechanical loading — Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.
4. Circuit overloading — Consideration should be given to the connection of the
equipment to the supply circuit and the effect that overloading of the circuits might have
on overcurrent protection and supply wiring. Appropriate consideration of equipment
nameplate ratings should be used when addressing this concern.
5. Reliable earthing (grounding) — Reliable earthing of rack-mounted equipment
should be maintained. Particular attention should be given to supply connections other
than direct connections to the branch circuit (such as the use of power strips).
XPA Ultra Series Power Amplifiers • Installation 7
Rack Mounting
The XPA Ultra Series amplifiers can be rack mounted using one of the following methods.
Rack Ear Rack Mounting
The XPA Ultra Series amplifiers ship with a set of rack ears so the half rack-width amplifiers
can be installed in a full rack width space.
Mount the amplifier with the rack ears as follows:
1. If feet were installed on the bottom of the amplifier, remove them.
2. Attach the included rack ears to the sides of the amplifier with the four provided #6
machine screws (see figure3,
1
).
e
XPA U 1004 SERIES
1 2 3 4
OVER
TEMP
LIMITER/PROTECT
SIGNAL
POW
ER
AMPL
IFIERS
1
Figure 3. Install XPA Ultra Rack Ears
3. Insert the amplifier into the rack, align the holes in the rack ears with the holes on the
rack.
4. Secure the amplifier to the rack using four provided 10-32 x 3/4” screws (see
figure4,
2
).
e
XPA U 1004 SERIES
1 2 3 4
OVER
TEMP
LIMITER/PROTECT
SIGNAL
POWER
AMPL
IFIERS
2
Figure 4. Secure XPA Ultra Amplifier to Rack
3 Install XPA Ultra Rack Ears
4 Secure XPA Ultra to Rack
XPA Ultra Series Power Amplifiers • Installation 8
Bridge Plate Rack Mounting
The XPA Ultra Series amplifiers ship with a bridge plate connector for connecting two XPA
Ultra Series amplifiers together to form a full rack width unit.
Connect and mount two XPA Ultra Series amplifiers as follows:
1. If feet were installed on the bottom of the amplifiers, remove them.
2. Position the two amplifiers upside down and next to each other.
3. Use the bridge plate connector and four provided #4 machine screws to connect the
two amplifiers together (see figure5,
1
).
4. Attach the two short rack ears to the amplifiers with four provided #6 machine screws
(
2
).
e
XPA U 1
004 SERIES
1 2 3 4
OVER
TEMP
LIMITER/PROTE
CT
SIGNAL
POWER AMPLIFIE
RS
e
e
XPA U 1004 SERIES
1 2 3 4
OVER
TEMP
L
IMITER/PR
OTE
CT
S
IGNAL
P
OWER A
MPLIFIE
R
S
Machine
screws (4)
2
1
Figure 5. Install XPA Ultra Series Bridge Plate
5. Insert the amplifiers into the rack, align the holes in the rack ears with the holes on the
rack.
6. Secure the amplifiers to the rack using four provided 10-32 x 3/4” screws (see
figure6,
1
).
e
XPA U 1004 SERIES
1 2 3 4
OVER
TEMP
LIMITER/PROTECT
SIGNAL
POWER AMPLIFIERS
ES
RS
e
XPA U 1004 SERIES
1 2 3 4
OVER
TEMP
LIMITER/PROTECT
SIGNAL
POWER
AMPL
IFIERS
1
Figure 6. Secure Connected XPA Ultra Amplifiers to Rack
5 Bridging Plate
6 Secure Connected XPAs to Rack
XPA Ultra Series Power Amplifiers • Installation 9
Rack Shelf Mounting
The XPA Ultra Series can be mounted in a shelf using the optional RSU 129 1U Universal
Rack Shelf Kit or the RSB 129 1U Basic Rack Shelf.
Mount the amplifier with the shelf as follows:
1. If feet were installed on the bottom of the amplifier, remove them.
2. Place the amplifier on one half of the rack shelf.
3. Align the front of the amplifier with the front of the shelf, and align the threaded holes on
the bottom of the amplifier with the holes in the rack shelf.
4. Attach the amplifier to the rack shelf with the two provided 4-40 x 3/16” machine
screws.
ATTENTION:
Using screws longer than 3/16” will damage the unit and void the warranty.
L’utilisation de vis plus longues que 3/16” endommagera l’unité et annulera la
garantie.
5. Insert the screws from the underside of the shelf, and securely fasten them into
diagonally-opposite corners.
(2) 4-40 x 3/16"
Screws
RSU 129
1U Universal Rack Shelf
False faceplate
uses 2 screws.
Use 2 mounting holes
on opposite corners.
e
XPA U 1004 SERIES
1
2 3 4
OVER
TEMP
LIMIT
ER/PROTECT
SIGNAL
POWER AMPLIFIERS
Figure 7. Mounting the Amplifier onto a Rack Shelf
6. Attach the false front panel (provided with the rack shelf) to the unoccupied side of the
rack, or install a second half rack width device in that side by repeating steps 1 through
5.
7. Attach the rack shelf to the rack using four 10-32 x 3/4” screws (provided). Insert the
screws through #10 beveled washers, then through the holes in the rack (see figure7).
7 Rack Mounting the Amplifier
XPA Ultra Series Power Amplifiers • Installation 10
Rack Mounting Ventilation Recommendations
Excessive heat can decrease the optimal lifetime of the power amplifier. An over temp
indicator LED on the front panel of the amplifier lights red whenever the recommended
operating temperature has been exceeded.
To reduce the chances of an over temp condition, the XPA Ultra amplifiers should be
arranged in a rack environment such that the environment around the amplifier does not
reach or exceed +122 °F (+50 °C). No more than four stacks of XPA Ultra amplifiers should
be arranged one-on-top-of-the-other in a rack without an open space between the stacks
(see figure8).
The XPA Ultra can also be arranged above or below another non-XPA Ultra device. In this
case, the environment around the amplifier should not reach or exceed +122 °F (+50 °C).
Vent Space
Vent Space
Vent Space
Vent Space
Vent Space
Vent Space
Vent Space
Figure 8. Vent Space Example
8 Vent Space Example
XPA Ultra Series Power Amplifiers • Installation 11
Flexible Conduit Adapter Kit Installation
WARNING:
AVERTISSEMENT :
The circuit breaker used for this connection should be rated no lower than 20 amps
and no greater than 30 amps.
Le disjoncteur utilisé pour cette connexion devrait avoir une cote comprise entre 20
et 30amps.
This unit must be installed in accordance with the National Electrical Code and with
all local codes.
L’unité doit être installée conformément au NationalElectricCode et aux normes
électriques et de sécurité locales.
An ALL-POLE MAINS SWITCH with a contact separation of at least 3 mm in each
pole shall be incorporated in the electrical installation of the building. The installation
shall be carried out in accordance with all applicable installation rules.
Un interrupteur omnipolaire avec une séparation contact d’au moins 3mm dans
chaque pôle, devra être incorporée dans l’installation électrique du bâtiment.
L’installation doit être réalisée conformément à toutes les règles d’installation
applicables.
Installation and service must be performed by a qualified electrician only.
L’installation et l’entretien doivent être effectués uniquement par un électricien
qualifié.
Make sure that the source device and the XPA are turned off and disconnected
from the power source before you begin.
Éteindre tous les appareils d’entrée et de sortie puis retirer les câbles
d’alimentation. Vérifiez que le XPA soit déconnecté de la source d’alimentation
avant de procéder.
To reduce the risk of fire or electric shock, do not expose this apparatus to rain or
moisture.
Afin de réduire les risques d’incendie ou de choc électrique, protégez cet appareil
de la pluie ou de l’humidité.
The Product is a Class I product, which must be connected only to a mains socket
outlet with a protective earthing (grounding) connection.
Ce produit est un produit de ClasseI, qui doit être connecté seulement à une prise
femelle secteur équipée d’une connexion de mise à la terre.
The mains plug/appliance coupler is used as the disconnect device and shall
remain readily operable.
La fiche secteur ou le coupleur est un système de déconnexion dont le
fonctionnement immédiat constitue un facteur essentiel.
ATTENTION:
A UL-listed electrical distribution box is required for the termination of the conduit
opposite the XPA (see UL Requirements on the next page).
Un boîtier de distribution électrique listé UL est recommandé pour la terminaison du
conduit à l’opposé du XPA.
XPA Ultra Series Power Amplifiers • Installation 12
The optional Flexible Conduit Adapter Kit consists of:
One conduit adapter plate (pre-attached), for PS 124 and XPA 1002/2001 amplifiers
One conduit adapter plate for XPA Ultra Series amplifiers (not attached)
One 6-foot long electrical conduit
Three 7.5-foot, 18-gauge spade connector power wires
One UL-rated zip tie wrap
Three auxiliary crimp style spade connectors designed for 14- to 16-gauge wires
NOTE: If needed, Extron recommends using a UL-rated crimp tool to terminate the
spade connectors. One recommended choice is Molex crimp tool.
The kit provides a convenient means to replace the IEC power cord of the XPA Ultra with
conduit, where required by local codes.
UL Requirements
The UL requirements listed below pertain to the installation of the flexible conduit onto an
XPAUltra Series product.
This unit is not to be used beyond its rated voltage range
This unit must be wired to a UL-listed distribution box
NOTE: The UL-approved electrical distribution box is not included with either
the XPA Ultra or the Flexible Conduit Adapter Kit. The installer is responsible for
obtaining and installing the box.
Installing the Flexible Conduit Adapter Kit
ATTENTION:
Electrostatic discharge (ESD) can damage IC chips even though you cannot feel it.
You must be electrically grounded before touching anything inside the XPA Ultra. A
grounding wrist strap is recommended.
Les décharges électrostatiques peuvent endommager les puces de circuit
même si vous ne pouvez pas les sentir, les voir ou les entendre. Vous devez être
électriquement relié à la terre avant de toucher quoique ce soit à l’intérieur du XPA
Ultra. Un bracelet de mise à la terre est recommandé.
To install the flexible conduit to the XPA Ultra:
1. Unplug the IEC power cord from the amplifier.
2. Remove the 8 screws from the top, bottom, and sides of the XPA and lift off the cover
(see figure9).
100-240V
--A, 50-60 Hz
CLASS 2 WIRING
0
2
4
6
8
10
12
14
2
0
2
4
6
8
10
14
12
4
3
0
2
4
6
8
10
14
12
1
0
2
4
6
8
10
14
18
26
12
1
2
3
4
G
STANDBY
SIGNAL
1
LIMITER/
PROTECT
2
ATTENUATION
INPUTS
REMOTE
OUTPUTS
XPA U 1004
3
4
8Ω/4Ω
Remove (8)
screws
Slide cover forward and
lift straight up.
Figure 9. Removing the Cover
9 Removing the Cover
XPA Ultra Series Power Amplifiers • Installation 13
3. Remove the 2 screws holding the blue (hot) line and brown neutral wires from the
terminal block on the PCB (see figure 10). Place the screws aside to be used later.
4. Remove the ground wire nut from the grounding stud on the bottom of the enclosure,
as shown in figure 10. Place the wire nut with the other screws to be used later.
5. Remove the wires attached to the IEC connector from the body of the XPA Ultra and
slide the IEC connector and attached wires up and out of the XPA Ultra enclosure
(figure10).
L
N
Blue Wire
Brown Wi
re
Disconnect cables
and r
emove IEC
connector
.
100-240V 1.3A
50-60Hz
Remove nut
Figure 10. Removing the IEC Connector
6. Remove the washer at the end of the conduit (washer-B in figure11) and remove the
conduit adapter plate that ships with the kit.
Separate adapter plate
and washer fr
om conduit.
Washer-A
Washer-B
Figure 11. Remove the Existing Adapter Plate
7. Place the adapter plate that ships with the conduit kit on the conduit with the flat side of
the plate facing the hexagonal nut and secure the new adapter plate to the conduit with
the washer removed in step 6 (see figure12).
PA Ultra Series Conduit Adapter Plate
Place the adpater plate
with the at side against
washer-A and secure with
washer-B.
Figure 12. Secure XPA Ultra Series Adapter Plate to Conduit
8. Thread the blue, brown, and green 18-gauge power wires included with the Flexible
Conduit Adapter Kit through the length of the electrical conduit.
10 Removing the IEC Connector
11 Installing the EMT Adapter Plate
12 Installing the EMT Adapter Plate
XPA Ultra Series Power Amplifiers • Installation 14
9. Install the conduit with the new conduit plate attached into the opening from which the
IEC connector was removed in step 5 (see figure13).
10. Connect the blue hot (line) and brown neutral wires to the terminal block on the PCB
using the 2 screws that were removed in step 3. Use the included zip tie wrap to secure
the two wires together close to the terminals (figure13).
WARNING: Ensure that you observe correct wire polarity. The following
illustration shows the location of the hot (line) and neutral terminals.
AVERTISSEMENT : Respecter la polarité correcte des câble. L’illustration suivante
indique l’emplacement des bornes de ligne et de neutre.
L
N
Slide the conduit
assembly into
the enclosue.
50-60Hz
100-240V 1.3A
Blue Wire
Brown Wir
e
Tie Wrap
Figure 13. Install the Conduit Assembly
11. Connect the ground wire, as shown above, to the grounding stud on the bottom of the
enclosure using the nut that was removed in step 4.
12. Replace the cover of the XPA Ultra by attaching the 8 screws that were removed in
step2.
13 Installing the EMT Adapter Plate
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Extron XPA Ultra Series Manuel utilisateur

Catégorie
Amplificateurs audio
Taper
Manuel utilisateur

dans d''autres langues