This unit is designed for installation in standard
double hung windows with actual opening widths
from 21" to 35" (533mm to 889mm).
The top and bottom window sashes must open
sufficiently to allow a clear vertical opening of 12"
(305mm) from the bottom of the upper sash to the
inside sill.
●
21" to 35"
12" (305mm) min
1
To prevent vibration and noise, make sure
the unit is installed securely and firmly.
4
Install the unit slightly tilted so the back is
slightly lower than the front (about 1/4"
(6.35mm)). This will force condensed water
to flow to the outside.
5
Install the unit with the bottom between
30"~60" (762mm~1524mm) above the floor
level.
2
Install the unit out of direct sunlight.
3
Fence
Awning
Heat
radiation
Cooled air
CAUTION
●
There should be no obstacles, such as a
fence or wall, within 20" (508mm) from the
back of the cabinet because it will prevent
heat radiation of the condenser.
Restriction of outside air will greatly reduce
the cooling efficiency of the air conditioner.
DO NOT cover or block any of the side and
top louvers. All side louvers of the cabinet
must remain exposed to the outside of the
structure and unobstructed.
●
This product is a window air conditioner.
As such, a standard single-hung or double-hung
window is required for proper installation.
Non-window installations, including using sleeves
or wall openings, and other installation methods
are not recommended.
1
2
If necessary, attach another 1" x 2"
(25.4mm x
50.8mm)
wood strip flush against the back of
the inner sill. This will raise the L bracket, as
shown in the drawing.
Windows that include a storm window frame
may prevent the air conditioner from tilting
down toward the outside to drain properly.
For proper drainage, attach a 1" x 2" (25.4mm x
50.8mm) piece of wood to the inner sill, trimmed
to a length which fits inside the window frame.
The top of the wood shim must be at least 3/4"
(19.05mm) higher than the top of the storm
window frame. Attach the wood securely to the
sill with nails or screws.
Indoors
Inner Sill
Nail or screw
Outer Sill
Storm
Window Frame
Wood Strip Mounted
on Top of Inner Sill
3/4” (19.05mm)
higher than storm
window frame
Wood Strip for
L bracket
L Bracket
Outdoors
NOTE
●
All supporting parts should be secured to firm
wood, masonry, vinyl, fiberglass, or metal.
Storm Window Requirements
Window Requirements
How to Install the Unit
11 EN
INSTALLATION
About
Over
1/4″ (6.35mm)
20″ (508mm)
(762mm~1524mm)
30″~60″
(533mm to 889mm)