Ubiquiti UniFi Dream Machine Guide de démarrage rapide

Taper
Guide de démarrage rapide

Ce manuel convient également à

UDM AC Power Cord
Package Contents
System Requirement
Either of the following is required:
iOS or Android™ Mobile Device with UniFi Network App Installed
Web Browser: Google Chrome (Other browsers may have limited functionality)
IMPORTANT: We strongly recommend using UPS backup and power
regulation to prevent equipment damage due to stability issues with
local AC power.
Hardware Overview
UDM Quick Start Guide
System LED
LAN (Ports 1-4)
Internet Port
Power Port
Reset Button
White Device is ready to be configured
Flashing White
Device is booting up
Device is initializing/deinitializing
Heartbeat White Firmware update in process
Blue Device is configured and ready
Slow Flashing Blue Client connected to device via Bluetooth (BLE)
Flashing Off/White/Blue
Device is in recovery mode.
The LED will cycle through a pattern at one-
second intervals, between off, white, and blue.
RJ45 switch ports support 10/100/1000 Ethernet connections for the LAN
(Local Area Network). By default, they are set to DHCP Server with the
fallback IP address, 192.168.1.1/24.
The RJ45 port supports a 10/100/1000 Ethernet connection. Set to DHCP
Client by default.
Connect the included AC Power Cord.
Resets to factory defaults. The device should be running after bootup is
complete. Press and hold the Reset button for about 10 seconds until the
UDM Quick Start Guide
System LED becomes solidly lit light blue. After a few seconds, the LED will
turn off, and the device will automatically reboot.
Installation Requirements
Use Category 5 (or above) UTP cabling approved for indoor use.
Hardware Installation
1.
2.
3.
UDM Quick Start Guide
Note: You can use Bluetooth on your smartphone to set up the device.
Configuration
You have the following options:
Enable Bluetooth on your mobile device and use the UniFi Network app.
Enable Wi-Fi on your mobile device and connect to UDM Setup <XXXX>
(XXXX is the last four characters of the device’s MAC address found on the
bottom device label). Go to “Chrome Instructions”.
Use a computer connected to the device on any LAN port, 1-4. Go to “Chrome
Instructions”.
UniFi Network App
1.
UDM Quick Start Guide
2.
3. Follow the on-screen instructions.
Chrome Instructions
Use the Chrome web browser to set up your device.
1. Ensure that your host system is on the same Layer 2 network as the UDM.
2. Launch the Chrome web browser and go to https://setup.ui.com
3. Follow the on-screen instructions of the Setup Wizard.
You can manage your network and view network statistics using the UniFi
Network Controller management interface. For information on using the UniFi
Network Controller software, refer to the User Guide located on our website at:
ui.com/download/unifi
Specifications
UDM
Dimensions ø110 x184.2 mm
(ø4.33 x 7.25")
UDM Quick Start Guide
UDM
Weight 1.05 kg
(2.32 lb)
Networking Interfaces (4) 10/100/1000 RJ45 Ports
Max. Power Consumption 26W
Power Method AC Power Cord
Power Supply Internal AC/DC Power Adapter,
(24V, 0.6A)
Supported Voltage Range 100 - 240VAC
LED System Status
Operating Frequency 2.4 GHz
5 GHz
Max. TX Power
2.4 GHz 23 dBm
5 GHz 30 dBm
Antenna (1) Dual-Band, Quad-Polarity Antenna
Antenna Gain
2.4 GHz 3 dBi
5 GHz 4.5 dBi
Wi-Fi Standards 802.11 a/b/g/n/ac/ac-wave2
Wireless Security WEP, WPA-PSK,
WPA-Enterprise (WPA/WPA2, TKIP/AES)
Operating Temperature -10 to 45° C (14 to 113° F)
Operating Humidity 5 to 95% Noncondensing
Certifications CE, FCC, IC
Safety Notices
1. Read, follow, and keep these instructions.
2. Heed all warnings.
3. Only use attachments/accessories specified by the manufacturer.
WARNING: Hot surface. Do not touch.
WARNING: Do not use this product in location that can be submerged by water.
WARNING: Avoid using this product during an electrical storm. There may be a
remote risk of electric shock from lightning.
UDM Quick Start Guide
Limited Warranty
ui.com/support/warranty
The limited warranty requires the use of arbitration to resolve disputes on an individual basis,
and, where applicable, specify arbitration instead of jury trials or class actions.
Compliance
FCC
Changes or modifications not expressly approved by the party responsible for compliance
could void the users authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions.
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause
undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
Consult the dealer or an experienced radio/TV technician for help.
The device has been approved by the FCC under FCC ID: SWX-UDM.
ISED Canada
CAN ICES-3(B)/NMB-3(B)
This device complies with ISED Canada licence-exempt RSS standard(s). Operation is
subject to the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, including interference that may cause
undesired operation of the device.
The device has been approved by ISED Canada under IC: 6545A-UDM.
The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the
potential for harmful interference to co-channel mobile satellite systems.
CAN ICES-3(B)/NMB-3(B)
UDM Quick Start Guide
Le présent appareil est conforme aux CNR d’ISDE Canada applicables aux appareils radio
exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :
1. l’appareil ne doit pas produire de brouillage;
2. l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
L’appareil ont été approuvés par ISDE Canada en vertu IC: 6545A-UDM.
Les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement pour
une utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux
systèmes de satellites mobiles utilisant les mêmes canaux.
IMPORTANT NOTE:
Radiation Exposure Statement:
This equipment complies with radiation exposure limits set forth for an uncontrolled
environment.
This equipment should be installed and operated with minimum distance 20 cm between
the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna
or transmitter.
AVIS IMPORTANT :
Déclaration sur l’exposition aux rayonnements :
Cet équipement est conforme aux limites prévues pour l’exposition aux rayonnements
dans un environnement non contrôlé.
Lors de l’installation et de la mise en fonctionnement de l’équipement, assurez-vous qu’il
y ait une distance minimale de 20 cm entre l’élément rayonnant et vous.
Cet émetteur ne doit être installé à proximité d’aucune autre antenne ni d’aucun autre
émetteur, et ne doit être utilisé conjointement à aucun autre de ces appareils.
Australia and New Zealand
Brazil
Nota: Este equipamento não tem direito à proteção contra interferência prejudicial e
não pode causar interferência em sistemas devidamente autorizados.
CE Marking
CE marking on this product represents the product is in compliance with all directives that
are applicable to it.
UDM Quick Start Guide
Country List
AT BE BG CY CZ DE DK EE EL ES FI FR HR HU
IE IT LV LT LU MT NL PL PT RO SE SI SK UK
BFWA (Broadband Fixed Wireless Access) members noted in blue
Note: This device meets Max. TX power limit per ETSI regulations.
The following apply to products that operate in the 5 GHz frequency range:
Note: This device is restricted to indoor use only when operating in the 5150 - 5350
MHz frequency range within all member states.
Note: All countries listed may operate at 30 dBm. BFWA member states may
operate at 36 dBm.
Note: Operation in the 5.8 GHz frequency band is prohibited in BFWA member
states. Other countries listed may use the 5.8 GHz frequency band.
WEEE Compliance Statement
Declaration of Conformity
Online Resources
© 2019 Ubiquiti Inc. All rights reserved.
UDM Quick Start Guide
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

Ubiquiti UniFi Dream Machine Guide de démarrage rapide

Taper
Guide de démarrage rapide
Ce manuel convient également à

dans d''autres langues