Halsey Taylor XP.C Le manuel du propriétaire

Taper
Le manuel du propriétaire
XP8WQ*1C
PAGE 1 97427C (Rev. G - 6/09)
HALSEY TAYLOR OWNERS MANUAL
USES HFC-134A REFRIGERANT
FIG. 1
1, 2, 3
31
15, 18
36
27
32
21
33
35
23
34
30
28
6, 17, 408
20
12
19
13, 14
SEE FIG. 3
4, 7, 16
25, 26, 39
37
38
XP8WQ*1C
PAGE 297427C (Rev. G - 6/09)
FIG. 2
E = INSURE PROPER VENTILATION BY MAINTAINING 4" (102mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 4" (102mm) (MÍN.) DE HOLGURA ENTRE LA
REJILLA DE VENTILACIÓN DEL MUEBLE Y LA PARED
ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 4" (102mm) (MIN.) ENTRE LES ÉVENTS DE L’ENCEINTE ET LE
MUR.
F = WALL SCREW HOLES
AGUJEROS DE TORNILLOS DE PARED
TROUS DE VIS DU MUR
G = 2 X 4 BLOCKING
BLOQUEO DE 2 X 4
BLOC 2 X 4
FINISHED FLOOR
PISO ACABADO
PLANCHER FINI
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2 IN. (38mm) OUT
FROM WALL SHUT OFF BY OTHERS
SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3/8" DE DIÁM. EXT. A 1-1/2"
(38mm) FUERA DE LA LLAVE DE PASO EN LA PARED COLOCADA POR TERCEROS.
EMPLACEMENT RECOMMANDÉ D'ALIMENTATION EN EAU PAR TUBE EN CUIVRE NON PLAQUÉ DE 3/8 PO. (9,5 mm) D.E.
CONNECTANT UNE TUYAUTERIE DE 1-1/2 PO. (38mm) DEPUIS LE ROBINET D'ARRÊT FOURNI PAR D'AUTRES.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN
UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1¼” DE DIÁMETRO.
EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4" DE SORTIE D’EAU.
C = 1-1/4 TRAP NOT FURNISHED**
PURGADOR DE 1¼ NO PROPORCIONADO**
SIPHON 1-1/4 NON FOURNI**
D = ELECTRICAL OUTLET LOCATION
UBICACIÓN DE LA TOMA DE ELECTRICIDAD
EMPLACEMENT DE LA PRISE DE COURANT
XP8WQ*1C
PAGE 3 97427C (Rev. G - 6/09)
17
24
91110
5, 22, 29
ADJUST THIS SCREW TO ELIMINATE VALVE LEVER "FREE PLAY"
OR CONTINUOUS FLOW FROM BUBBLER
STREAM HEIGHT
ADJUSTMENT SCREW
CORRECT STREAM HEIGHT
FIG. 5
PUSH BUTTON VALVE ADJUSTMENT
FIG. 3
FIG. 4
CONDENSER WATER VALVE ADJUSTMENT
The condenser water valve is factory preset for a condenser water outlet temperature of 95° to 105° F.
If actual temperature varies greatly from this, readjust water flow rate at the valve using the following procedures.
1. START UP COMPRESSOR
This can be accomplished by depressing the cooler push button (See Fig. 1 - Item 3). Keep water
running during the entire readjustment procedure.
2. ADJUSTMENT CONDENSER WATER VALVE
Adjust valve by rotating adjustment stem. Rotating stem clockwise will decrease water flow.
Counterclockwise rotation will increase water flow. Increasing water flow will result in a lower
condenser outlet temperature, while decreasing water flow will result in a higher outlet temperature.
Proper adjustment is attained when condenser outlet temperature is 95° to 105° F.
XP8WQ*1C
PAGE 497427C (Rev. G - 6/09)
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR VISIT OUR WEBSITE WWW.HALSEYTAYLOR.COM
2222 CAMDEN COURT
OAK BROOK, IL 60523
630.574.3500
PRINTED IN U.S.A.
PARTS LIST 115V
DESCRIPTION
1
2
3
4
5
6
7
8
9
10
11
12*
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
NS
Stem Bushing
Push Button Stem
Cap Push Button
Drain Plug
Nut-Regulator Retaining
Bubbler Nipple
Strainer Plate
Basin
Regulator Lever
Pivot Bracket
Regulator Retaining Bracket
Compressor Service Pak
Overload
Relay
Cold Control Assy
Gasket - Drain
Bubbler
Electrical Box-Cold Control
Heat Exchanger
Electrical Box-Power Connection
Tailpipe Assy
Regulator Holder
Union - 1/4
Regulator Mounting Bracket
Nut - Slip Joint 1-1/4
Adaptor-Drain W/O Holes
Strainer
Condenser Assy
Regulator
Drier
Evaporator
Tee - 1/4 x 1/4 x 1/4
Check Valve
Elbow - 3/8
Right Panel
Left Panel
Poly Tubing (Cut To Length)
Brkt - Conduit Support
Gasket
Washer
Front Panel
101452331870
101507531550
101453431640
102639931640
15005C
56159C
160270508640
28346C
26860C
26861C
26862C
36220C
35797C
35803C
600793851550
100147140560
51544C
45340C
66336C
45347C
45448C
50986C
70683C
55880C
75588C
55913C
55996C
66798C
61314C
66202C
66505C
70682C
75494C
75561C
401536242830
401536342830
56092C
28368C
75589C
100322740560
401507442830
PART NO.ITEM
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE
WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NOTE: All correspondence pertaining to any of the above water coolers
or orders for repair parts MUST include Model No. and Serial No. of
cooler, name and part number of replacement part.