Siemens MCP 1500 SINUMERIK ONE Manuel utilisateur

Taper
Manuel utilisateur
SINUMERIK
SINUMERIK ONE
ONE MCP Part 2: MCP 1500
Equipment Manual
Valid for:
Control system
SINUMERIK ONE
SINUMERIK 840D sl/840DE sl
05/2022
A5E52027171B AA
Fundamental safety
instructions 1
Overview 2
Dimension drawings 3
Operator control and
display elements 4
Technical data 5
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage
to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices
referring only to property damage have no safety alert symbol. These notices shown below are graded according to
the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will be
used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property
damage.
Quali󹇽ed Personnel
The product/system described in this documentation may be operated only by personnel quali󹇽ed for the speci󹇽c
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Quali󹇽ed personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended or
approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance
are required to ensure that the products operate safely and without any problems. The permissible ambient
conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identi󹇽ed by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may
be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software described.
Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this
publication is reviewed regularly and any necessary corrections are included in subsequent editions.
Siemens AG
Digital Industries
Postfach 48 48
90026 NÜRNBERG
GERMANY
Document order number: A5E52027171B AA
Ⓟ 05/2022 Subject to change
Copyright © Siemens AG 2022.
All rights reserved
Table of contents
1 Fundamental safety instructions ........................................................................................................... 5
1.1 General safety instructions................................................................................................... 5
1.2 Equipment damage due to electric 󹇽elds or electrostatic discharge ....................................... 8
1.3 Warranty and liability for application examples ..................................................................... 9
1.4 Security information ............................................................................................................ 9
1.5 Residual risks of power drive systems ................................................................................. 10
2 Overview.............................................................................................................................................. 13
3 Dimension drawings............................................................................................................................ 15
4 Operator control and display elements ............................................................................................... 17
4.1 Front side .......................................................................................................................... 17
4.2 Rear side............................................................................................................................ 18
4.3 Con󹇽guration..................................................................................................................... 19
5 Technical data...................................................................................................................................... 21
Index .................................................................................................................................................... 25
ONE MCP Part 2: MCP 1500
Equipment Manual, 05/2022, A5E52027171B AA 3
Table of contents
ONE MCP Part 2: MCP 1500
4Equipment Manual, 05/2022, A5E52027171B AA
Fundamental safety instructions 1
1.1 General safety instructions
WARNING
Electric shock and danger to life due to other energy sources
Touching live components can result in death or severe injury.
Only work on electrical devices when you are quali󹇽ed for this job.
Always observe the country-speci󹇽c safety rules.
Generally, the following steps apply when establishing safety:
1. Prepare for disconnection. Notify all those who will be a󹇼ected by the procedure.
2. Isolate the drive system from the power supply and take measures to prevent it being
switched back on again.
3. Wait until the discharge time speci󹇽ed on the warning labels has elapsed.
4. Check that there is no voltage between any of the power connections, and between any of
the power connections and the protective conductor connection.
5. Check whether the existing auxiliary supply circuits are de-energized.
6. Ensure that the motors cannot move.
7. Identify all other dangerous energy sources, e.g. compressed air, hydraulic systems, or
water. Switch the energy sources to a safe state.
8. Check that the correct drive system is completely locked.
After you have completed the work, restore the operational readiness in the inverse sequence.
WARNING
Electric shock due to connection to an unsuitable power supply
When equipment is connected to an unsuitable power supply, exposed components may carry
a hazardous voltage. Contact with hazardous voltage can result in severe injury or death.
Only use power supplies that provide SELV (Safety Extra Low Voltage) or PELV- (Protective
Extra Low Voltage) output voltages for all connections and terminals of the electronics
modules.
ONE MCP Part 2: MCP 1500
Equipment Manual, 05/2022, A5E52027171B AA 5
WARNING
Electric shock due to equipment damage
Improper handling may cause damage to equipment. For damaged devices, hazardous
voltages can be present at the enclosure or at exposed components; if touched, this can result
in death or severe injury.
Ensure compliance with the limit values speci󹇽ed in the technical data during transport,
storage and operation.
Do not use any damaged devices.
WARNING
Electric shock due to unconnected cable shields
Hazardous touch voltages can occur through capacitive cross-coupling due to unconnected
cable shields.
As a minimum, connect cable shields and the cores of cables that are not used at one end
at the grounded housing potential.
WARNING
Electric shock if there is no ground connection
For missing or incorrectly implemented protective conductor connection for devices with
protection class I, high voltages can be present at open, exposed parts, which when touched,
can result in death or severe injury.
Ground the device in compliance with the applicable regulations.
NOTICE
Damage to equipment due to unsuitable tightening tools.
Unsuitable tightening tools or fastening methods can damage the screws of the equipment.
Only use screw inserts that exactly match the screw head.
Tighten the screws with the torque speci󹇽ed in the technical documentation.
Use a torque wrench or a mechanical precision nut runner with a dynamic torque sensor and
speed limitation system.
Adjust the tools used regularly.
Fundamental safety instructions
1.1 General safety instructions
ONE MCP Part 2: MCP 1500
6Equipment Manual, 05/2022, A5E52027171B AA
WARNING
Spread of 󹇽re from built-in devices
Built-in devices can cause a 󹇽re and a pressure wave in the event of a fault. Fire and smoke can
escape from the control cabinet and cause serious personal injury and property damage.
Install built-in appliances in a robust metal control cabinet that is suitable for protecting
people from 󹇽re and smoke.
Only operate built-in devices with the control cabinet doors closed.
Ensure that smoke can only escape via controlled and monitored paths.
WARNING
Unexpected machine movement caused by radio devices or mobile phones
Using radio devices, cellphones, or mobile WLAN devices in the immediate vicinity of the
components can result in equipment malfunction. Malfunctions may impair the functional
safety of machines and can therefore put people in danger or lead to property damage.
Therefore, if you move closer than 20 cm to the components, be sure to switch o󹇼 radio
devices, cellphones or WLAN devices.
Use the "SIEMENS Industry Online Support app" only on equipment that has already been
switched o󹇼.
WARNING
Fire due to inadequate ventilation clearances
Inadequate ventilation clearances can cause overheating of components with subsequent 󹇽re
and smoke. This can cause severe injury or even death. This can also result in increased
downtime and reduced service lives for devices/systems.
Ensure compliance with the speci󹇽ed minimum clearance as ventilation clearance for the
respective component.
NOTICE
Overheating due to inadmissible mounting position
The device may overheat and therefore be damaged if mounted in an inadmissible position.
Only operate the device in admissible mounting positions.
Fundamental safety instructions
1.1 General safety instructions
ONE MCP Part 2: MCP 1500
Equipment Manual, 05/2022, A5E52027171B AA 7
WARNING
Unexpected movement of machines caused by inactive safety functions
Inactive or non-adapted safety functions can trigger unexpected machine movements that
may result in serious injury or death.
Observe the information in the appropriate product documentation before commissioning.
Carry out a safety inspection for functions relevant to safety on the entire system, including
all safety-related components.
Ensure that the safety functions used in your drives and automation tasks are adjusted and
activated through appropriate parameterizing.
Perform a function test.
Only put your plant into live operation once you have guaranteed that the functions
relevant to safety are running correctly.
Note
Important Safety instructions for Safety Integrated
If you want to use Safety Integrated functions, you must observe the Safety instructions in the
Safety Integrated documentation.
1.2 Equipment damage due to electric 󹇽elds or electrostatic discharge
Electrostatic sensitive devices (ESD) are individual components, integrated circuits, modules or
devices that may be damaged by either electric 󹇽elds or electrostatic discharge.
NOTICE
Equipment damage due to electric 󹇽elds or electrostatic discharge
Electric 󹇽elds or electrostatic discharge can cause malfunctions through damaged individual
components, integrated circuits, modules or devices.
Only pack, store, transport and send electronic components, modules or devices in their
original packaging or in other suitable materials, e.g conductive foam rubber of aluminum
foil.
Only touch components, modules and devices when you are grounded by one of the
following methods:
Wearing an ESD wrist strap
Wearing ESD shoes or ESD grounding straps in ESD areas with conductive 󹇾ooring
Only place electronic components, modules or devices on conductive surfaces (table with
ESD surface, conductive ESD foam, ESD packaging, ESD transport container).
Fundamental safety instructions
1.2 Equipment damage due to electric 󹇽elds or electrostatic discharge
ONE MCP Part 2: MCP 1500
8Equipment Manual, 05/2022, A5E52027171B AA
1.3 Warranty and liability for application examples
Application examples are not binding and do not claim to be complete regarding con󹇽guration,
equipment or any eventuality which may arise. Application examples do not represent speci󹇽c
customer solutions, but are only intended to provide support for typical tasks.
As the user you yourself are responsible for ensuring that the products described are operated
correctly. Application examples do not relieve you of your responsibility for safe handling when
using, installing, operating and maintaining the equipment.
1.4 Security information
Siemens provides products and solutions with industrial security functions that support the
secure operation of plants, systems, machines and networks.
In order to protect plants, systems, machines and networks against cyber threats, it is necessary
to implement – and continuously maintain – a holistic, state-of-the-art industrial security
concept. Siemens’ products and solutions constitute one element of such a concept.
Customers are responsible for preventing unauthorized access to their plants, systems,
machines and networks. Such systems, machines and components should only be connected to
an enterprise network or the internet if and to the extent such a connection is necessary and only
when appropriate security measures (e.g. 󹇽rewalls and/or network segmentation) are in place.
For additional information on industrial security measures that may be implemented, please
visit
https://www.siemens.com/industrialsecurity (https://www.siemens.com/industrialsecurity).
Siemens’ products and solutions undergo continuous development to make them more secure.
Siemens strongly recommends that product updates are applied as soon as they are available
and that the latest product versions are used. Use of product versions that are no longer
supported, and failure to apply the latest updates may increase customer’s exposure to cyber
threats.
To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed
under
https://www.siemens.com/cert (https://www.siemens.com/cert).
Further information is provided on the Internet:
Fundamental safety instructions
1.4 Security information
ONE MCP Part 2: MCP 1500
Equipment Manual, 05/2022, A5E52027171B AA 9
Industrial Security Con󹇽guration Manual (https://support.industry.siemens.com/cs/ww/en/
view/108862708)
WARNING
Unsafe operating states resulting from software manipulation
Software manipulations, e.g. viruses, Trojans, or worms, can cause unsafe operating states in
your system that may lead to death, serious injury, and property damage.
Keep the software up to date.
Incorporate the automation and drive components into a holistic, state-of-the-art industrial
security concept for the installation or machine.
Make sure that you include all installed products into the holistic industrial security concept.
Protect 󹇽les stored on exchangeable storage media from malicious software by with suitable
protection measures, e.g. virus scanners.
On completion of commissioning, check all security-related settings.
1.5 Residual risks of power drive systems
When assessing the machine- or system-related risk in accordance with the respective local
regulations (e.g., EC Machinery Directive), the machine manufacturer or system installer must
take into account the following residual risks emanating from the control and drive components
of a drive system:
1. Unintentional movements of driven machine or system components during commissioning,
operation, maintenance, and repairs caused by, for example,
Hardware and/or software errors in the sensors, control system, actuators, and cables and
connections
Response times of the control system and of the drive
Operation and/or environmental conditions outside the speci󹇽cation
Condensation/conductive contamination
Parameterization, programming, cabling, and installation errors
Use of wireless devices/mobile phones in the immediate vicinity of electronic components
External in󹇾uences/damage
X-ray, ionizing radiation and cosmic radiation
2. Unusually high temperatures, including open 󹇾ames, as well as emissions of light, noise,
particles, gases, etc., can occur inside and outside the components under fault conditions
caused by, for example:
Component failure
Software errors
Operation and/or environmental conditions outside the speci󹇽cation
External in󹇾uences/damage
Fundamental safety instructions
1.5 Residual risks of power drive systems
ONE MCP Part 2: MCP 1500
10 Equipment Manual, 05/2022, A5E52027171B AA
3. Hazardous shock voltages caused by, for example:
Component failure
In󹇾uence during electrostatic charging
Induction of voltages in moving motors
Operation and/or environmental conditions outside the speci󹇽cation
Condensation/conductive contamination
External in󹇾uences/damage
4. Electrical, magnetic and electromagnetic 󹇽elds generated in operation that can pose a risk to
people with a pacemaker, implants or metal replacement joints, etc., if they are too close
5. Release of environmental pollutants or emissions as a result of improper operation of the
system and/or failure to dispose of components safely and correctly
6. In󹇾uence of network-connected communication systems, e.g. ripple-control transmitters or
data communication via the network
For more information about the residual risks of the drive system components, see the relevant
sections in the technical user documentation.
Fundamental safety instructions
1.5 Residual risks of power drive systems
ONE MCP Part 2: MCP 1500
Equipment Manual, 05/2022, A5E52027171B AA 11
Fundamental safety instructions
1.5 Residual risks of power drive systems
ONE MCP Part 2: MCP 1500
12 Equipment Manual, 05/2022, A5E52027171B AA
Overview 2
This manual describes the speci󹇽c properties of the SINUMERIK ONE MCP 1500 machine control
panel. The documentation is always structured in 2 parts. Part 1 contains general information
that applies to all machine control panels. Part 2 covers speci󹇽cs of individual machine control
panels. Both parts of the documentation must always be observed.
More information
You can 󹇽nd more information about SINUMERIK ONE MCPs in:
SINUMERIK ONE MCP - Part 1: MCP xxxx
Validity
The following description applies to the following component:
Designation Article number
SINUMERIK ONE MCP 1500 6FC5303-0AP01-0AA0
View
Figure 2-1 MCP 1500
ONE MCP Part 2: MCP 1500
Equipment Manual, 05/2022, A5E52027171B AA 13
Overview
ONE MCP Part 2: MCP 1500
14 Equipment Manual, 05/2022, A5E52027171B AA
Dimension drawings 3
q
q
 
*) Plus wiring portion
Figure 3-1 Front, rear and side view of MCP 1500 (all speci󹇽cations in mm)
The installation clearance for the MCPs is 70 mm including the wiring portion.
Panel cutout
The MCP 1500 is attached to the rear side of the operator panel using 8 tension jacks (contained
in the scope of delivery). The tightening torque is 0.4 Nm.


All corner radii R5 or chamfer 5x45°
Figure 3-2 Panel cutout
ONE MCP Part 2: MCP 1500
Equipment Manual, 05/2022, A5E52027171B AA 15
Dimension drawings
ONE MCP Part 2: MCP 1500
16 Equipment Manual, 05/2022, A5E52027171B AA
Operator control and display elements 4
4.1 Front side
Overview
 
 
Emergency stop
Keypad 1 (operating mode block)
Keypad 2 (axis block)
Powerride 2 (spindle) + keypad 2.2
Powerride 1 (feed) + keypad 2.1
4x mounting space for 22.5 mm element
Keypad 1.2
Keypad 1.1
Key-operated authorization switch
Figure 4-1 Position of operator controls on the MCP 1500
ONE MCP Part 2: MCP 1500
Equipment Manual, 05/2022, A5E52027171B AA 17
4.2 Rear side
 
Power supply interface X10
Switch S2
Ethernet interfaces X20 port 1/ port 2
Emergency stop
Handwheel connections X60/ X61
Protective conductor connection
Interface of the customer-speci󹇽c inputs/outputs X516
Interface of the customer-speci󹇽c inputs/outputs X515
4x mounting space for 22.5 mm element
*
)
Installation of the control panel with 8 clamping elements to the mounting opening provided in the
frame Clamping elements are provided in the accessory kit of the device.
Figure 4-2 Rear view of the MCP 1500
Handwheel connecting cable
The handwheel connecting cable is not included in the scope of delivery. You will 󹇽nd the article
numbers in Chapter "Spare parts/accessories".
Operator control and display elements
4.2 Rear side
ONE MCP Part 2: MCP 1500
18 Equipment Manual, 05/2022, A5E52027171B AA
4.3 Con󹇽guration
Input image
Slot 1 Base
Slot 2 Keypad 1 (operating mode block), keypad 1.1 and keypad 1.2
Slot 3 Keypad 2 (axis block), keypad 2.1 and keypad 2.2
Slot 4 Powerride 1 (feed)
Slot 5 Powerride 2 (spindle)
Slot 6 Handwheel 1
Slot 7 Handwheel 2
Output image
Slot 1 Base
Slot 2 Keypad 1 (operating mode block), keypad 1.1 and keypad 1.2
Slot 3 Keypad 2 (axis block), keypad 2.1 and keypad 2.2
Slot 4 Powerride 1 (feed)
Slot 5 Powerride 2 (spindle)
Operator control and display elements
4.3 Con󹇽guration
ONE MCP Part 2: MCP 1500
Equipment Manual, 05/2022, A5E52027171B AA 19
Operator control and display elements
4.3 Con󹇽guration
ONE MCP Part 2: MCP 1500
20 Equipment Manual, 05/2022, A5E52027171B AA
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26

Siemens MCP 1500 SINUMERIK ONE Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues