Extron FOX Matrix 3200 Manuel utilisateur

Taper
Manuel utilisateur

Ce manuel convient également à

68-1740-51 Rev. B
10 19
FOX Matrix 3200
FOX Matrix 7200
Modular Fiber Optic Matrix Switchers
Fiber Optic Matrix Switchers
Setup Guide
Safety Instructions
Safety Instructions • English
WARNING: This symbol, , when used on the product, is
intended to alert the user of the presence of uninsulated
dangerous voltage within the product’s enclosure that may
present a risk of electric shock
.
ATTENTION: This symbol, , when used on the product, is
intended to alert the user of important operating and
maintenance (servicing) instructions in the literature provided
with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron
website, www.extron.com.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den
Benutzer darauf aufmerksam machen, dass im Inneren
des Gehäuses dieses Produktes gefährliche Spannungen
herrschen, die nicht isoliert sind und die einen elektrischen
Schlag verursachen können.
VORSICHT: Dieses Symbol auf dem Produkt soll dem
Benutzer in der im Lieferumfang enthaltenen Dokumentation
besonders wichtige Hinweise zur Bedienung und Wartung
(Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien,
Produkthandhabung, EMI/EMF-Kompatibilität, Zugänglichkeit und
verwandte Themen finden Sie in den Extron-Richtlinien für Sicherheit
und Handhabung (Artikelnummer 68-290-01) auf der Extron-Website,
www.extron.com.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar
dentro del producto, lo que puede representar un riesgo de
descarga eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto,
avisa al usuario de la presencia de importantes instrucciones
de uso y mantenimiento recogidas en la documentación
proporcionada con el equipo.
Para obtener información sobre directrices de seguridad, cumplimiento
de normativas, compatibilidad electromagnética, accesibilidad y
temas relacionados, consulte la Guía de cumplimiento de normativas
y seguridad de Extron, referencia 68-290-01, en el sitio Web de Extron,
www.extron.com
.
Instructions de sécurité • Français
AVERTISSEMENT: Ce pictogramme, , lorsqu’il est utilisé
sur le produit, signale à l’utilisateur la présence à l’intérieur
du boîtier du produit d’une tension électrique dangereuse
susceptible de provoquer un choc électrique.
ATTENTION: Ce pictogramme, , lorsqu’il est utilisé sur le produit,
signale à l’utilisateur des instructions d’utilisation ou de
maintenance importantes qui se trouvent dans la documentation
fournie avec le matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la
réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets
connexes, lisez les informations de sécurité et de conformité Extron, réf.
68-290-01, sur le site Extron,
www.extron.com.
Istruzioni di sicurezza • Italiano
AVVERTENZA: Il simbolo, , se usato sul prodotto,
serve ad avvertire l'utente della presenza di tensione
non isolata pericolosa all'interno del contenitore
del prodotto che può costituire un rischio di scosse
elettriche.
ATTENTZIONE: Il simbolo, , se usato sul prodotto,
serve ad avvertire l'utente della presenza di importanti
istruzioni di funzionamento e manutenzione nella
documentazione fornita con l'apparecchio.
Per informazioni su parametri di sicurezza, conformità alle normative,
compatibilità EMI/EMF, accessibilità e argomenti simili, fare riferimento
alla Guida alla conformità normativa e di sicurezza di Extron, cod.
articolo 68-290-01, sul sito web d
i Extron, www.extron.com.
Instrukcje bezpieczeństwa • Polska
OSTRZEŻENIE: Ten symbol, , gdy używany na produkt, ma
na celu poinformować użytkownika o obecności izolowanego i
niebezpiecznego napięcia wewnątrz obudowy produktu, który
może stanowić zagrożenie porażenia prądem elektrycznym.
UWAGI: Ten symbol, , gdy używany na produkt, jest
przeznaczony do ostrzegania użytkownika ważne operacyjne
oraz instrukcje konserwacji (obsługi) w literaturze, wyposażone
w sprzęt.
Informacji na temat wytycznych w sprawie bezpieczeństwa, regulacji
wzajemnej zgodności, zgodność EMI/EMF, dostępności i Tematy
pokrewne, zobacz Extron bezpieczeństwa i regulacyjnego zgodności
przewodnik, część numer 68-290-01, na stronie internetowej Extron,
www.extron.com.
Инструкция по технике
безопасности Русский
ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан
на продукте, предупреждает пользователя о
наличии неизолированного опасного напряжения
внутри корпуса продукта, которое может привести к
поражению электрическим током.
ВНИМАНИЕ: Данный символ, , если указан на
продукте, предупреждает пользователя о наличии
важных инструкций по эксплуатации и обслуживанию в
руководстве, прилагаемом к данному оборудованию.
Для получения информации о правилах техники
безопасности, соблюдении нормативных требований,
электромагнитной совместимости (ЭМП/ЭДС), возможности
доступа и других вопросах см. руководство по безопасности
и соблюдению нормативных требований Extron на сайте
Extron: www.extron.com, номер по каталогу - 68-290-01.
安全说明 体中文
警告 产品上的这个标志意在警告用户该产品机壳内有暴露的危险
电 压 ,有 触 电 危 险
注意 产品上的这个标志意在提示用户设备随附的用户手册中有
重要的操作和维护(维修)说明。
关于我们产品的安全指南、遵循的规范、EMI/EMF 的兼容性、无障碍
使用的特性等相关内容,敬请访问 Extron 网站 www.extron.com,参见
Extron 安全规范指南,产品编号 68-290-01
NOTE: For more information on safety guidelines, regulatory compliances,
EMI/EMF compatibility, accessibility, and related topics, see the “
Extron Safety and
Regulatory Compliance Guide
” on the Extron website.
Copyright
© 2014-2019 Extron Electronics. All rights reserved. www.extron.com
Trademarks
All trademarks mentioned in this guide are the properties of their respective owners.
The following registered trademarks, registered service marks, and trademarks are the property of RGB
Systems, Inc. or Extron Electronics (see the current list of trademarks on the Terms of Use page at
www.extron.com):
Registered Trademarks
(®)
Extron, AVTrac, Cable Cubby, ControlScript, CrossPoint, DTP, eBUS, EDID Manager, EDID Minder,
FlatField, FlexOS, Glitch Free, GlobalConfigurator, Global Scripter, GlobalViewer, Hideaway,
HyperLane, HyperLane, IPIntercom, IPLink, KeyMinder, LinkLicense, LockIt, MediaLink, MediaPort,
NetPA, PlenumVault, PoleVault, PowerCage, PURE3, Quantum, Show Me, SoundField, SpeedMount,
SpeedSwitch, StudionStation, SystemINTEGRATOR, TeamWork, TouchLink, V-Lock, VersaTools,
VN-Matrix, VoiceLift, WallVault, WindoWall, XTP, XTPSystems, and ZipClip
Registered Service Mark
(SM)
: S3 Service Support Solutions
Trademarks
(
)
AAP, AFL (Accu-RATEFrameLock), ADSP(Advanced Digital Sync Processing), Auto-Image,
AVEdge,CableCover, CDRS(ClassDRippleSuppression), DDSP(Digital Display Sync Processing), DMI
(DynamicMotionInterpolation), DriverConfigurator, DSPConfigurator, DSVP(Digital Sync Validation
Processing), eLink, EQIP, EverLast, FastBite, Flex55, FOX, FOXBOX, IP Intercom HelpDesk, MAAP,
MicroDigital, Opti-Torque, ProDSP, QS-FPC(QuickSwitch Front Panel Controller), Room Agent,
Scope-Trigger, ShareLink, SIS, SimpleInstructionSet, Skew-Free, SpeedNav, Triple-Action Switching,
True4K, Vector™ 4K, WebShare, XTRA, and ZipCaddy
安全記事 繁體中文
警告: 若產品上使用此符號是為提醒使用產品機殼內存在著
能會導致觸電之風險的未絕緣危險電壓
意 品上使用此符號是為提醒使用設備隨附的用戶
冊中有重要的操作和維護維修)説明
有關安全性指導方針、法規遵守、EMI/EMF 相容性、存取範圍和相關
主題的詳細資訊,請瀏覽 Extron 網站:www.extron.com,然後參閱
《Extron 安全性與法規遵守手冊》,準則編號 68-290-01。
安全上の注意 日本語
警告:この が製品上に表示されている場合は、筐体内に絶
縁されて いない高が流れ、感電の危があることを示し
す。
意: この 製品上に表示されている場合は、本機の取
説明書に 記載されている重要な操作と保守(備)の指示につい
てユーザーの 注意を喚起するもので
安全上のご注意、法規厳守、EMI/EMF適合性、その他の関連項目に
スト イト
www.extron.com
Extron Safety and Regulatory Compliance Guide(P/N 68-290-01)
をごくだ
안전 지침 한국어
경고: 이 기호 , 가 제품에 사용될 경우, 제품의 인클로저 내에 있는
접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이
있음을 경고합니다.
주의: 이 기호 , 가 제품에 사용될 경우, 장비와 함께 제공된
책자에 나와 있는 주요 운영 및 유지보수(정비) 지침을
경고합니다.
안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련
항목에 대한 자세한 내용은 Extron 웹 사이트(www.extron.com)의 Extron
안전 및 규제 준수 안내서, 68-290-01 조항을 참조하십시오.
FCC Class A Notice
This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part15 of the FCC rules.
The ClassA limits provide reasonable protection against harmful
interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is
likely to cause interference. This interference must be corrected at the
expense of the user.
NOTE: The Twisted Pair Extension technology works with
unshielded twisted pair (UTP) or shielded twisted pair (STP)
cables; but to ensure FCC Class A and CE compliance, STP
cables and STP Connectors are required.
For more information on safety guidelines, regulatory
compliances, EMI/EMF compatibility, accessibility, and related
topics, see the “Extron Safety and Regulatory Compliance
Guide” on the Extron website.
Conventions Used in this Guide
Notifications
WARNING: Potential risk of severe injury or death.
AVERTISSEMENT: Risque potentiel de blessure grave ou de
mort.
ATTENTION:
Risk of property damage.
Risque de dommages matériels.
NOTE: A note draws attention to important information.
Software Commands
Commands are written in the fonts shown here:
^AR Merge Scene,,Op1 scene 1,1 ^B 51 ^W^C
[01]
R
0004
00300
00400
00800
00600
[02]
35
[17]
[03]
E X! *X1&* X2)* X2#* X2! CE}
NOTE: For commands and examples of computer or device
responses mentioned in this guide, the character “0” is used for
the number zero and “O” is the capital letter “o.”
Computer responses and directory paths that do not have variables
are written in the font shown here:
Reply from 208.132.180.48: bytes=32 times=2ms TTL=32
C:\Program Files\Extron
Variables are written in slanted form as shown here:
ping
xxx.xxx.xxx.xxx —t
SOH R
Data STX Command ETB ETX
Selectable items, such as menu names, menu options, buttons, tabs,
and eld names are written in the font shown here:
From the File menu, select New.
Click the OK button.
Specifications Availability
Product specications are available on the Extron website,
www.extron.com.
FOX Matrix 3200 and FOX Matrix 7200 • Contents vii
Contents
Introduction .................................... 1
About this Guide ........................... 1
About the FOX Matrix Switchers ... 2
Congurability and
Transmission modes ................ 3
Installation ...................................... 5
Rear Panel ..................................... 5
A Note on I/O Boards ................ 5
Making Connections ................. 7
Front Panel .................................. 10
Front Panel Operations ............... 11
Creating a Tie .............................. 11
Viewing Ties
(and Muting Outputs) ................. 12
Saving or Recalling a Preset ....... 12
Locking the Front Panel
(Executive Mode) ....................... 13
Remote Control ........................... 15
Selected SIS Commands ............ 15
Command and Response
Table for SIS Commands ........... 16
Matrix Switchers
Control Program ........................ 20
Installing the Program ............. 20
LAN port Connection............... 21
Starting the Program ............... 21
Built-in HTML Pages ................... 23
Conguring for Network
Communication ...................... 23
Loading the Start-up Page ...... 24
Maintenance and
Modifications ............................... 27
Removing and Installing
a Board or Blank Panel .............. 27
Removing and Installing
a Power Supply Module............. 29
Removing and Installing
a Fan Module ............................. 31
viii FOX Matrix 3200 and FOX Matrix 7200 • Contents
FOX Matrix 3200 and FOX Matrix 7200 • Introduction 1
Introduction
WARNING: The fiber optic I/O boards of the FOX matrix
switchers output continuous invisible light, which may be
harmful to the eyes; use with caution.
Do not look into the fiber optic cable connectors or into the
fiber optic cables themselves.
Plug the attached dust caps into the optical transceivers when
the fiber cable is unplugged.
AVERTISSEMENT : L'appareil émet une lumière invisible en
continu, à utiliser avec precaution.
Ne regardez pas dans les connecteurs de câble fibre optique
sur le panneau arrière ou dans les câbles fibre optique eux-
mêmes.
Branchez les protections contre la poussière dans l'ensemble
émetteur/récepteur lorsque le câble fibre optique est débranché.
This section provides an overview of the Extron FOX Matrix 3200 and
FOX Matrix 7200 and describes their features. Topics that are covered
include:
About this Guide
About the FOX Matrix Switchers
About this Guide
NOTE: For more information on any subject in this guide, see
the FOX Matrix 3200 and FOX Matrix 7200 Series User Guide,
available at www.extron.com.
This setup guide helps you easily and quickly set up and congure
your FOX Matrix 3200 and FOX Matrix 7200 switcher. Step by step
instructions show you how to:
Install the input and output boards
Connect the hardware
Perform basic operations
Use both the front panel controls and selected Simple
Instruction Set (SIS) commands
Load and start the Matrix Switchers Control Program
Connect to the built-in HTML pages, which you can use to
operate the switcher
2 FOX Matrix 3200 and FOX Matrix 7200 • Introduction
About the FOX Matrix Switchers
The FOX Matrix Switchers (see gure1 for a FOX Matrix 3200 example)
are congurable matrix switchers that distribute optical signals. Fiber
optic I/O boards route signals that are compatible with all Extron
FOX 500, FOXBOX, FOX, FOX 2G, and FOX HD-SDI ber optic product
lines. 3G/HD-SDI/SDI/ I/O boards route 3G, high denition serial digital
interface (HD-SDI), and serial digital interface (SDI) signals. The matrix
switcher routes any input signal to any combination of outputs. An
optical input can be tied to optical outputs, 3G/HD-SDI SDI outputs,
or both and an 3G/HD-SDI SDI input can be tied to 3G/HD-SDI/
SDI outputs, optical outputs, or both. The matrix switcher can route
multiple input/output congurations simultaneously.
ANAHEIM, CA
RESET
REMOTE
RS-232/RS-422
LAN
BI-LEVEL
TRI-LEVEL
ACT LINK
100-240V 50/60Hz 1.2A MAX.
100-240V 50/60Hz 1.2A MAX.
REDUNDANT
PRIMARY
DISCONNECT BOTH POWER
CORDS BEFORE SERVICING
SWITCH
REFERENCE
PRIMARY POWER SUPPLY
REDUNDANT POWER SUPPLY
1 - 8
9 - 16
17 - 24
25 - 32
A
B
C
D
E
F
G
H
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
A
B
C
D
E
F
G
H
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
MUTI-RATE SDI INPUTS
H
G
AD
E
F
C
B
MUTI-RATE SDI OUTPUTS
H
G
AD
E
F
C
B
MUTI-RATE SDI INPUTS
H
G
AD
E
F
C
B
MUTI-RATE SDI OUTPUTS
H
G
AD
E
F
C
B
12V
0.3A MAX
FOX HDSDI
HD/SDI IN
POWER
BUFFERED OUTPUTS
MODE
OPTICAL
RxTx
12
12V
0.3A MAX
FOX HDSDI
HD/SDI IN
POWER
BUFFERED OUTPUTS
MODE
OPTICAL
RxTx
12
12V
0.3A MAX
FOX HDSDI
HD/SDI IN
POWER
BUFFERED OUTPUTS
MODE
OPTICAL
RxTx
12
12V
0.3A MAX
FOX HDSDI
HD/SDI IN
POWER
BUFFERED OUTPUTS
MODE
OPTICAL
RxTx
12
POWER
PHONES
INPUT
MIXING
EXT
1-4
IMX
5-8REC
REC
CH1
5 CH2 6
UNITY VARIABLE
CH3
7 CH4 8 CUE
CUE
L
R
MONITOR
PREVIEWAUTO EDIT
DMC EDIT DELETE
REVIEW
LIST GOOD SHOT MARK TRIM
CH1
5 CH2 6 CH3 7 CH4 8
PB
REC
PB
REMOTE
EJECT
1(9P) 2(50P) RS-232C
MPEG IMXDigital BETACAM HDCAM
HDCAM
High Definition
Video System
MEMORY
REC/
ERASE
AUDIO
ENTRY
PREROLL
REW
REC
PLAY
EDIT
F FWD
STANDBY
STOP
IN
IN
OUT
OUT
REC INHI
R
E
V
E
R
S
E
F
O
R
W
A
R
D
JOG
SHUT
T
L
E
VAR
F1 F2 F3 F4 F5 F6
JOG
HOME
SHUTTLE/VAR
DISPLAY
FULL/FINE
CHANNEL
CONDITION
ASSEMBLEINSERT
VIDEO CH1 CH2 CH3 CH3 CUE
RESET
TC
00:00:00:00
KEY INHI
ALARM
PUSH/
SHIFT
MULTI
CONTROL
PLAYER
RECORDER
HD SDI HD SDI HD SDI HD SDI
db db db db
0
10
20
30
40
50
0
10
20
30
40
50
0
10
20
30
40
50
0
10
20
30
40
50
db
0
10
20
30
40
50
POWER
PHONES
INPUT
MIXING
EXT
1-4
IMX
5-8REC
REC
CH1
5 CH2 6
UNITY VARIABLE
CH3
7 CH4 8 CUE
CUE
L
R
MONITOR
PREVIEW AUTO EDIT
DMC EDIT DELETE
REVIEW
LIST GOOD SHOT MARK TRIM
CH1
5 CH2 6 CH3 7 CH4 8
PB
REC
PB
REMOTE
EJECT
1(9P) 2(50P) RS-232C
MPEG IMXDigital BETACAM HDCAM
HDCAM
High Definition
Video System
MEMORY
REC/
ERASE
AUDIO
ENTRY
PREROLL
REW
REC
PLAY
EDIT
F FWD
STANDBY
STOP
IN
IN
OUT
OUT
REC INHI
R
E
V
E
R
S
E
F
O
R
W
A
R
D
JOG
SH
U
TT
L
E
VA
R
F1 F2 F3 F4 F5 F6
JOG
HOME
SHUTTLE/VAR
DISPLAY
FULL/FINE
CHANNEL
CONDITION
ASSEMBLE INSERT
VIDEO CH1 CH2 CH3 CH3 CUE
RESET
TC
00:00:00:00
KEY INHI
ALARM
PUSH/
SHIFT
MULTI
CONTROL
PLAYER
RECORDER
HD SDI HD SDI HD SDI HD SDI
db db db db
0
10
20
30
40
50
0
10
20
30
40
50
0
10
20
30
40
50
0
10
20
30
40
50
db
0
10
20
30
40
50
H
C
OM
M
U
NICA
TIO
N
Tx
CO
M
M
UN
IC
A
T
IO
N
Tx
FOX 3G HD-SDI
Multimode
FOX 3G HD-SDI
Multimode
FOX 3GHD-SDI
Singlemode
FOX Matrix 3200
FOX 3G HD-SDI
Singlemode
M
M
S
S
Multimode
I/O Board
Singlemode
I/O Board
H
H
SDI/HD-SDI
I/O Board
Singlemode
Multimode
SDI/HD-SDI
NOTE: In this figure, the FOX 3G HD-SDI units
are set to bidirectional transceiver mode.
Figure 1. Typical FOX Matrix 3200 application
The Extron proprietary ber optic signal, generated by Extron ber
optic transmitters, can include video, stereo audio, and transmitter-
to-receiver RS-232 serial communications. The video component of
the signal can be RGB video, Digital Visual Interface (DVI) video, HDMI
video, 3G/HD-SDI/SDI video, or low resolution video, depending on the
transmitter and receiver.
The matrix switcher can be remotely controlled via its Ethernet LAN
port or either of two serial ports, one on the rear panel and one on the
front panel, using either the Windows-based Extron Matrix Switchers
Control Program or the SIS.
1
FOX Matrix 3200 and FOX Matrix 7200 • Introduction 3
NOTES:
Compatible optical signals are digital signals from 270 Mbs
through 4.25 Gbps that are sent and received via fiber optic
small form factor pluggable (SFP) modules.
The FOX transmitter-to-receiver communications, including
the serial link, occupy one matrix switcher input and output.
This matrix switcher can also support the FOX return
(receiver-to-transmitter) serial communications, but returning
this signal stream to the transmitter occupies a separate
matrix switcher input and output.
The switcher has two internal, hot-swappable 100 VAC to 240 VAC,
50-60 Hz, 175-watt (FOX Matrix 3200) or 180-watt (FOX Matrix 7200)
power supplies that provide worldwide power compatibility and
reliability.
Configurability and Transmission modes
The FOX Matrix Switchers are assembled from individual input/output
(I/O) boards. The switcher can include up to four (FOX Matrix 3200) or
nine (FOX Matrix 7200) I/O boards, each of which supports 8 inputs by
8 outputs. The four types of I/O boards are:
Singlemode fiber optic 8x8 I/O board
Multimode fiber optic 8x8 I/O board
Singlemode pathological fiber optic 8x8 I/O board. This board
addresses the compatibility issues of passing pathological signals
generated from 3G HD-SDI, HD-SDI, and SDI signals over fiber
optic systems
3G HD-SDI, HD-SDI, and SDI 8x8 I/O board
NOTE: As listed above, three versions of the fiber optic I/O
boards are documented in this manual. They are categorized by
the type of fiber optic cable, multimode or singlemode, which
defines the effective range of transmission:
SinglemodeVery long distance, up to 30 km (18.75 miles)
Multimode — Long distance, up to 300 m (984 feet)
By adding or removing I/O boards, you can expand and contract the
FOX Matrix Switchers from an 8-input by 8-output matrix to up to
either:
FOX Matrix 3200 — A 32-input by 32-output matrix
FOX Matrix 7200 — A 72-input by 72-output matrix
NOTE: On a fiber optic I/O board as delivered from Extron,
all transceiver modules are configured the same: either all
multimode or all singlemode. You can mix multimode and
singlemode fiber optic I/O boards in a FOX matrix switcher, but
you must ensure that you connect the proper transmission mode
fiber cables to the board.
4 FOX Matrix 3200 and FOX Matrix 7200 • Introduction
FOX Matrix 3200 and FOX Matrix 7200 • Installation 5
Installation
This section describes installation of the FOX matrix switchers,
including connections and features. Topics that are covered include:
Rear Panel
Front Panel
Rear Panel
A Note on I/O Boards
As shown in gure2, each I/O board is identied by the input and
output numbers supported by the board position. The transceiver
modules on the I/O boards are identied as A through H.
ANAHEIM, CA
100-240V 50/60Hz 1.2A MAX.
PRIMARY POWER SUPPLY
1 - 8
9 - 16
17 - 24
A
B
C
D
E
F
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
A
B
C
D
E
F
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
25 - 32
MUTI-RATE SDI INPUTS
H
G
AD
E
F
C
B
D
C
AD
C
B
Location A
Input
Location A
Output and Input
Slot 1
(1-8)
O#1
I#1
Slot 2
(9-16)
Slot 3
No board
installed
Slot 4
(25-32)
O#2
I#2
O#3
I#3
O#4
I#4
O#9
I#25
I#26
I#27
I#28
I#29
I#30
I#31
I#32
O#25
O#26
I#9
O#10
I#10
O#11
I#11
O#12
I#12
O#5
I#5
O#6
O#13
I#13
O#14
Location A
Output
Location H
Input
AAA
AAA
BBB
Figure 2. Arrangement of Inputs and Outputs on the I/O Boards
The board position designators, printed beside the fans, correspond
to the input and output numbers served by that position (1 - 8, 9 - 16,
and so on).
The location designators, A through H, correspond to the transceiver
modules, numbered from left to right, each of which includes an input
and an output.
See gure2. The input and output numbers supported by the I/O
board in slot 2 (location 9 - 16) are as follows: A = 9, B = 10, C = 11,
D= 12, E = 13, F = 14, G = 15, and H = 16.
ATTENTION:
Turn off power to the input and output devices, and
disconnect their power cords before making connections.
Débranchez le produit et les autres appareils.
2
6 FOX Matrix 3200 and FOX Matrix 7200 • Installation
WARNING: This unit outputs continuous invisible light,
which may be harmful to the eyes; use with caution. For
additional safety, plug the attached dust caps into the
optical transceivers when the fiber cable is unplugged.
AVERTISSEMENT : L'appareil émet une lumière invisible en
continu, à utiliser avec precaution. Branchez les protections
contre la poussière dans l'ensemble émetteur/récepteur
lorsque le câble fibre optique est débranché.
ANAHEIM, CA
RESET
SWITCH REFERENCE
BI-LEVEL TRI-LEVEL
RS232/RS422
REMOTE
LAN
ACT
LINK
REDUNDANT
PRIMARY
PRIMARY POWER SUPPLY
REDUNDANT POWER SUPPLY
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
FAN ASSIMBLY
FAN ASSIMBLY
MUTI-RATE SDI INPUTS
H
G
AD
E
F
C
B
MUTI-RATE SDI OUTPUTS
H
G
AD
E
F
C
B
MUTI-RATE SDI INPUTS
H
G
AD
E
F
C
B
MUTI-RATE SDI OUTPUTS
H
G
AD
E
F
C
B
100-240V
50/60Hz
3.7A MAX.
100-240V
50/60Hz
3.7A MAX.
DISCONNECT BOTH POWER
CORDS BEFORE SERVICING
1 - 8
9 - 16
17 - 24
25 - 32
33 - 40
41 - 48
49 - 56
57 - 64
65 - 72
1 - 8
9 - 16
17 - 24
25 - 32
33 - 40
41 - 48
49 - 56
57 - 64
65 - 72
AAA
BBB CCC DDD EEEGGG HHH
III HHH FFF
Figure 3. FOX Matrix 7200 Switcher Rear Panel
A
Fiber optic boards with connectors and LEDs (see page 7).
B
3G HD-SDI, HDI-SDI, and SDI boards with connectors (see
page 8).
C
Remote port (see page 8).
D
Ethernet port (LAN connector) (see page 8).
E
Reset button and LED (see page 8).
F
Switch Reference connectors (see page 9).
G
Power connectors (see page 9).
3
7FOX Matrix 3200 and FOX Matrix 7200 • Installation
OUT
IN
OPTICAL
2* 1
*
OPTIONAL FOR
RETURN DATA
LINK
LINK
OPTICAL
Transmitting
Unit
Receiving
Unit
FOX Matrix
Switcher
12*
*
OPTIONAL FOR
RETURN DATA
LINK
LINK
2211
Figure 4. FOX Matrix 3200 Switcher Rear Panel
H
Power Supply indicator LEDs (see page 9).
I
Replaceable fans (see Removing and
Installing a Fan Module
on page31 to
replace the fan).
Making Connections
A
Fiber optic boards with connectors and
LEDs
NOTES:
Ensure that you use the proper
fiber cable for your I/O board.
Typically, singlemode fiber has
a yellow jacket and multimode
cable has an orange or cyan
jacket.
The FOX matrix switcher uses
one connector on the block
as an input and the second
connector on the same block as
a separate output.
1
Input connector — Connect a fiber
optic cable between each Input LC
connector and a FOX 500 Tx or any
other compatible Extron FOX device.
NOTE: Or, for the serial return
(receiver-to-transmitter)
function, connect the far end
to the Optical 2 connector on a
FOX Rx receiver.
Input LED — See Fiber optic I/O
board LED indications
on page9.
4
Fiber optic image
ANAHEIM, CA
RESET
REMOTE
RS-232/RS-422
LAN
BI-LEVEL
TRI-LEVEL
ACT LINK
100-240V 50/60Hz 1.2A MAX.
100-240V 50/60Hz 1.2A MAX.
REDUNDANT
PRIMARY
DISCONNECT BOTH POWER
CORDS BEFORE SERVICING
SWITCH
REFERENCE
PRIMARY POWER SUPPLY
REDUNDANT POWER SUPPLY
1 - 8
9 - 16
17 - 24
A
B
C
D
E
F
G
H
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
C
D
E
F
G
H
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
A
B
C
D
E
F
G
H
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
25 - 32
MUTI-RATE SDI INPUTS
H
G
AD
E
F
C
B
MUTI-RATE SDI OUTPUTS
H
G
AD
E
F
C
B
1 - 8
9 - 16
17 - 24
25 - 32
BI-LEVEL
TRI-LEVEL
DISCONNECT BOTH POWER
CORDS BEFORE SERVICING
SWITCH
REFERENCE
AAA
BBB
CCC
DDD
EEE
FFF
GGG
HHH HHH
III
8 FOX Matrix 3200 and FOX Matrix 7200 • Installation
2
Output connector — Connect a fiber optic cable between
each output LC connector and a FOX 500 Rx or any other
compatible Extron FOX device (see Fiber optic image on the
previous page).
NOTE: Or, for the serial return (receiver-to-transmitter)
function, connect the far end to the Optical 2
connector on a FOX Tx transmitter.
Output LED — See Fiber optic I/O board LED indications on
the next page.
B
SDI/HDI-SDI boards with BNC connectors — (see figure3
on page6
and figure4 on page7)
1
Multi-rate SDI Input connectors — Connect HD-SDI, SDI,
or 3G-SDI video inputs to these BNC connectors.
2
Multi-rate SDI Output connectors — Connect digital
displays to these BNC connectors.
C
Remote port — If desired, connect a control system or computer
to the rear panel Remote RS-232/RS-422 port.
RS-232 Function Pin Function
1
2
3
4
5
6
7
8
9
Tx
Rx
Gnd
Not used
Transmit
Receive
Not used
Ground
Not used
Not used
Not used
Not used
Tx–
Rx–
Gnd
Rx+
Tx+
Not used
Transmit (–)
Receive (–)
Not used
Ground
Not used
Receive (+)
Transmit (+)
Not used
RS-422
5
1
96
Figure 5. Audio Output Connector Wiring
D
LAN port — If desired, connect a network WAN or LAN hub, a
control system, or a computer to the Ethernet RJ-45 port.
Network connection — Wire as a patch (straight) cable.
Computer or control system connection — Wire the interface
cable as a crossover cable.
NOTE: The factory default IP address is 192.168.254.254.
E
Reset button — Initiates four levels of reset of the matrix
switcher. For different reset levels, press and hold the recessed
button while the switcher is running or while you power up the
switcher (see the FOX 3200 and 7200 Series User Guide, available
at www.extron.com).
NOTE: The factory configured passwords for all accounts
on this device have been set to the device serial number.
In the event of a complete system reset, the passwords
convert to the default, which is no password.
5
9FOX Matrix 3200 and FOX Matrix 7200 • Installation
F
Switch Reference connectors (affect SDI / HD-SDI inputs and
outputs only) — Connect an external sync signal to this BNC
connector to genlock the video signal in broadcast or other sync-
critical applications (see figure3
on page6 and figure4 on
page7
).
G
Power connectors — Plug the switcher into two grounded AC
sources.
NOTE: For reliability, connect the Redundant power cord to
either an uninterruptible power source or to a power source
that is completely independent from the primary power
source.
H
Primary and Redundant power supply indicator LEDs
Green — Indicates that the associated power supply is operating
within normal tolerances.
Red — Indicates that the associated power supply is operating
outside the normal tolerances or has failed (see Removing and
Installing a Power Supply Module
on page29 to replace the
power supply).
Fiber optic I/O board LED indications
On the ber optic I/O boards, the input and output LEDs on the
transceivers provide useful indications of the status of the lasers and
the reclocking function (see the table below).
OUT
IN
Definition
Output LED
indication
Input LED
indication
Definition
Reclocked at 4.25 Gbps
On On
Reclocked at 4.25 Gbps
Not reclocked, laser off,
or no signal
Off Off
Not reclocked or no
signal
Non-4G signal present
or not reclocked
Fast blink Fast blink
Non-4G signal present
or not reclocked
Not reclocked, laser on
or no signal
Slow blink Slow blink N/A
NOTE: If reclocking is set to bypass, the Output LED is always
on.
10 FOX Matrix 3200 and FOX Matrix 7200 • Installation
Front Panel
FOX 4G MATRIX 3200
FIBER OPTIC DIGITAL MATRIX SWITCHER
POWER SUPPLY
PRIMARY
REDUNDANT
CONTROL
ENTERPRESET
VIEW
ESC
CONFIG
AAA BBB
A
Configuration port — If desired, connect a control system or
computer to the front panel Configuration (RS-232) port. Use an
optional 9-pin D to 2.5 mm mini jack TRS RS-232 cable.
B
Primary and Redundant Power Supply LEDs
Green Indicates that the associated power supply is operating
within normal tolerances.
RedIndicates that the associated power supply is operating
outside the normal tolerances or has failed (see Removing and
Installing a Power Supply Module
on page29 to replace the
power supply).
FOX Matrix 3200 and FOX Matrix 7200 • Front Panel Operations 11
Front Panel Operations
This section describes simple matrix switcher operation from the front
panel. Topics that are covered include:
Creating a Tie
Viewing Ties (and Muting Outputs)
Saving or Recalling a Preset
Locking the Front Panel (Executive Mode)
Creating a Tie
A "tie" is an input-to-output connection.
A "set of ties" is an input tied to two or more outputs. (An output can
never be tied to more than one input.)
A "conguration" is one or more ties, one or more sets of ties, or a
combination.
1. Press and release the Esc button to clear any input button, output
button, or control button indicators that may be lit.
2. Press and release the desired input button.
5
3. Press and release the desired output buttons.
3 4
ENTER
8
The output buttons blink to indicate the potential ties.
The Enter button b
links to indicate
the need to confirm the change.
4. Press and release the Enter button. The tie is created and all
button indicators turn off.
12 FOX Matrix 3200 and FOX Matrix 7200 • Front Panel Operations
Viewing Ties (and Muting Outputs)
1. Press the View button. Output buttons light for outputs that have
no ties established.
NOTE: If an output button blinks, that output is muted. To
toggle mute on and off, press and hold the output button
for 2 seconds.
2.
Press an input button. The buttons for all tied outputs light.
3. Press an output button. The buttons for the tied input and all tied
outputs light.
4. Press the View button again to exit View mode. All input and
output buttons return to an unlit state.
Saving or Recalling a Preset
A "preset" is a conguration that has been stored.
1. Save a preset — Press and hold the Preset button until it
flashes.
PRESET PRESET
Preset button blinks.
Press and hold.
2 seconds
Sa
ve a
preset
Recall a preset — Press and release the Preset button.
PRESET PRESET
1 2 3 4 5 6 16
15
Recall a
preset
Preset button lights.
Press and release.
All input and output buttons with assigned presets light red.
When a preset is saved, the configuration data at
assigned preset locations will be overwritten
.
INPUTS
2. Press and release the desired input or output button.
1
ENTER
The button blinks red to indicate that
this preset is selected to save or recall.
Enter blinks red to
indicate the need to
activate the save or recall.
3. Press and release the Enter button.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42

Extron FOX Matrix 3200 Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues