ASD STANDARD SERIES Manuel utilisateur

Taper
Manuel utilisateur
Our slim LED wallpacks are designed to replace up to a 460w metal halide
producing an abundance of light with a fraction of the power. These low profile
durable fixtures are great for a downlight or uplight and are easily installed.
We offer a 5 year warranty with 36,000 hour L70 lifespan. This is an ideal
commercial outdoor fixture for buildings, parking garages, schools, and ware-
houses, is suitable for wet locations and harsh environments.
FEATURES AND BENEFITS:
5 Year warranty
LED lifetime (L70) > 36,000 hrs
No maintenance
Economical replacement
for an old outdated metal halide wallpack
Low profile design
Wet location IP65
Operating temperature of -40-104℉
cULus certified
DesignLightsTM Consortium (DLC)
listed (4.0 standard)
ORDERING MATRIX:
Family Modification DimmableWatts CCT
ASD-WLP 02
30 = 30 W
50 = 50 W
75 = 75 W
100 = 100 W
5000 KLED COB Cut-Off Wallpack Non-dimmable
NXX 50
ASD-WLP02-30N50 30 W NO 5000 K 2,850 lm 7.9" x 6.6" x 4.25"
ASD-WLP02-50N50 50 W NO 5000 K 4,750 lm 7.9" x 6.6" x 4.25"
ASD-WLP02-75N50 75 W NO 5000 K 7,125 lm 11.6" x 9.5" x 5.9"
ASD-WLP02-100N50 100 W NO 5000 K 10,000 lm 11.6" x 9.5" x 5.9"
Model Watts Dimming Compatible CCT Lumens Dimensions (L x W x H)
LED COB CUT-OFF WALLPACK:
IP65
rated
100
lm
HIGH LUMINOUS
EFFICIENCY
w
WebSite: www.asd-lighting.com Fax: 339-502-8970
Phone: 781-739-3977E-mail: [email protected]
LED COB Cut-Off Wallpack
Standard Series
PRODUCT SPECIFICATIONS:
Warranty & Certifications
5-year limited warranty
DesignLights™ Consortium (DLC) listed
cULus certified E473804
Lens Glass
Reflector Aluminum
Housing Aluminum
Finish Color Black
ASD-WLP02-30N50 3.6 lb (1.65 kg) ASD-WLP02-75N50 9 lb (4.1 kg)
ASD-WLP02-50N50 3.9 lb (1.8 kg) ASD-WLP02-100N50 9.4 lb (4.2 kg)
Construction & Materials
Weight
Work Environment Suitable for Wet Locations, IP65
Operating Temperature -40-104℉ (-40-40℃)
LED lifetime (L70) > 36,000 hrs
Environmental System
ASD-WLP02-30N50 95 lm/w ASD-WLP02-75N50 95 lm/w
ASD-WLP02-50N50 95 lm/w ASD-WLP02-100N50 100 lm/w
ASD-WLP02-30N50 2,716 lm ASD-WLP02-75N50 7,044 lm
ASD-WLP02-50N50 4,542 lm ASD-WLP02-100N50 10,277 lm
Color Temperature 5000 K
CRI 80
Optical System
Actual Luminous Flux
Luminous Efficacy
Input Voltage 100~277VAC 50/60 Hz
Off State Power 0 W
ASD-WLP02-30N50 30 W ASD-WLP02-75N50 75 W
ASD-WLP02-50N50 50 W ASD-WLP02-100N50 100 W
Power Factor ≥ 0.9
ASD-WLP02-30N50 25-36 V ASD-WLP02-75N50 60-90 V
ASD-WLP02-50N50 25-36 V ASD-WLP02-100N50 60-90 V
ASD-WLP02-30N50 900 mA ASD-WLP02-75N50 900 mA
ASD-WLP02-50N50 1500 mA ASD-WLP02-100N50 1200 mA
Electrical System
Power Consumption
Output voltage
Max current
WebSite: www.asd-lighting.com Fax: 339-502-8970
Phone: 781-739-3977E-mail: [email protected]
LED COB Cut-Off Wallpack
Standard Series
LED COB CUT-OFF WALLPACK ORDERING INFORMATION:
ASD-WLP02-30N50 30 W 5000 K 857622006428 10857622006425 026.0101 8 16.9"x9.1"x14.4" 34.3 lbs
ASD-WLP02-50N50 50 W 5000 K 857622006435 10857622006432 026.0102 8 16.9"x9.1"x14.4" 35.6 lbs
ASD-WLP02-75N50 75 W 5000 K 857622006442 10857622006449 026.0103 4 25"x12.6"x10.6" 39.8 lbs
ASD-WLP02-100N50 100 W 5000 K 857622006459 10857622006456 026.0104 4 25"x12.6"x10.6" 41.1 lbs
Model Watts CCT GTIN 12 GTIN 14
Product
Code
Pcs in one
Carton
Carton Size
Carton
Weight
ASD-WLP02-75N50 ASD-WLP02-100N50
ASD-WLP02-50N50
7.9 (201 mm)6.6” (168 mm)
4.25 (108 mm)
ASD-WLP02-30N50
LIGHT DISTRIBUTION CURVE [UNIT:CD]
C0 PLANE ISOLUX DIAGRAM (UNIT:lx)
3.3ft
6.6ft
0.0m 3.3m
13.1ft
19.69331
39.38671
59.08002
78.77341
98.46654
118.1599
137.8532
157.5465
177.2398
90°
±180°
-90°
-60°
-30°
60°
30°
-120°
-150°
120°
150°
424.10
848.20
1272.30
1696.40
2120.50
0.00
424.10
848.20
1272.30
1696.40
2120.50
45°-45° 90°-90° 135°-135° 180°-180°
C67.5(Max):
C0/C180:
C90/C270:
LIGHT DISTRIBUTION CURVE [UNIT:CD]
C0 PLANE ISOLUX DIAGRAM (UNIT:lx)
3.3ft
6.6ft
0.0m 3.3m
13.1ft
29.25381
58.50762
87.76143
117.0149
146.2686
175.5232
204.7769
234.0307
263.2844
90°
±180°
-90°
-60°
-30°
60°
30°
-120°
-150°
120°
150°
711.79
1423.58
2135.37
2847.15
3558.94
0.00
711.79
1423.58
2135.37
2847.15
3558.94
45°-45° 90°-90° 135° °081°531--180°
C112.5(Max):
C0/C180:
C90/C270:
LIGHT DISTRIBUTION CURVE [UNIT:CD]
C0 PLANE ISOLUX DIAGRAM (UNIT:lx)
3.3ft
6.6ft
0.0m 3.3m 6.6m
13.1ft
11.42416
22.84842
34.27258
45.69684
57.121
68.54526
79.96942
91.39368
102.8178
0.00
254.51
509.01
763.52
1018.02
1272.53
45°-45° 90°-90° 135° °081°531--180°
C90(Max):
C0/C180:
C90/C270:
90°
±180°
-90°
-60°
-30°
60°
30°
-120°
-150°
120°
150°
254.51
509.01
763.52
1018.02
1272.53
11.6” (294 mm)9.5 (240 mm)
5.9 (149 mm)
LIGHT DISTRIBUTION CURVE [UNIT:CD]
90°
±180°
-90°
-60°
-30°
60°
30°
-120°
-150°
120°
150°
0.00
45°-45° 90°-90° 135°-135° 180°-180°
1162.25
2324.50
3486.75
4648.99
5811.24
1162.25
2324.50
3486.74
4648.99
5811.24
C90(Max):
C0/C180:
C90/C270:
C0 PLANE ISOLUX DIAGRAM (UNIT:lx)
3.3ft
6.6ft
0.0m 3.3m
13.1ft
42.69331
85.38662
128.0799
170.7732
213.4665
256.1599
298.8531
341.5465
384.2398
WebSite: www.asd-lighting.com Fax: 339-502-8970
Phone: 781-739-3977E-mail: [email protected]
LED COB Cut-Off Wallpack
Standard Series
WARNING
RISK OF PERSONAL INJURY READ and follow all WARNINGS and installation instructions.
Keep or give to the owner for future reference.
Risk of cuts: Wear gloves to prevent cuts or abrasions when removing from carton, handling, installing, and maintaining this
product.
Risk of electric shock: This product must be installed in accordance with the applicable installation code by a person familiar
with the construction and operation of the product and the hazards involved.
Risk of Fire: Minimum 90°С supply conductors. Consult a qualified electrician to ensure correct branch circuit conductor.
ASD® assumes no responsibility for claims arising out of improper or careless Installation or handling of this product.
ADVERTENCIA
RIESGO DE LESIONES PERSONALES Lea y siga todas las advertencias e instrucciones de instalación.
Mantener о proporcionar al propletario para referencia futura.
Riesgo de cortes: Use guantes para evitar cortes о abrasiones en la eliminación de la caja, manejo, instalación y
mantenimlento de este producto.
Riesgo de choque eléctrico. Este pfoducto debe ser instalado de acuerdo con el código de Instalación uplicable en que una
persona familliarizada con la construcciôn y operación del producto y los riesgos Involucrados.
Riesgo de Incendio: Minimo 90° С los conductores de suministro. Consuite a un etectricista calificado para asegurarse el
conductor correcto del circuito.
ASD® no asume ninguna responsabilidad por reclamaciones derivadas de uno instaiación inadecuada о negfigente о la
manipuloción de este producto.
AVERTISSEMENT
RISQUE DE BLESSURES - Lisez et suivez toutes les MISES EN GARDE et les instructions d'installation.
Tenir ou fournir au propriétaire pour référence future.
Risque de coupures: Porter des gants pour éviter les coupures ou des écorchures lors du retrait du carton, de la manutention,
l'installation et le maintien de ce produit.
Risque de choc électrique: Ce produit doit être Installé conformément au code d'installation applicable par une personne
familiarisée avec la construction et l'exploitation du produit et les risques impliqués.
Risque d'incendie: minimum 90° С Alimentation conducteurs. Consultez un électricien qualifié pour assurer le bon
conducteur de circuit de dérivation.
ASD® n'assume aucune responsabilité pour les réclamations découlant d'une installation inadéquate ou négligente ou de la
manipulation de ce produit.
WebSite: www.asd-lighting.com Fax: 339-502-8970
Phone: 781-739-3977E-mail: [email protected]
LED COB Cut-Off Wallpack
Standard Series
Make sure that the supply voltage corresponds to the rated product voltage.
The product must be installed by a qualified electrician in accordance with the National
Electrical Code and corresponding local codes.
If the product is damaged, do not use it.
All wiring connections should be capped with UL approved wire connectors.
This fixture is intended to be connected to a properly installed and grounded UL listed
junction box with suitable strain relief means for power cord. The junction box is not
included, should be purchased separately.
IMPORTANT SAFETY INFORMATION:
INSTALLATION GUIDE
Please read all the instructions below before installation.
ELECTRICAL SCHEMATIC DIAGRAM
+
-
DRIVER
L
N
G
L
N
G
L (live/hot)
connect black
Ground
connect green
FIXTURE
N (neutral)
connect white
Power connector
120~277V 50/60 Hz
INSTALLATION STEPS
1. Remove screw.
2. Open the cover.
3. Affix gasket ¾ (gasket is not included
and should be purchased separately).
Insert power cord and connect wires
as in the picture below.
4. Close the cover and tighten screw.
2.1.
4.3.
gasket
WebSite: www.asd-lighting.com Fax: 339-502-8970
Phone: 781-739-3977E-mail: [email protected]
LED COB Cut-Off Wallpack
Standard Series
CONNECTING MULTIPLE FIXTURES TO ONE SWITCH
LINKING LIMITS:
ASD-WLP02-30N50 18 AWG/0.824 mm
2
16 pcs 32 pcs 46 pcs
ASD-WLP02-50N50 18 AWG/0.824 mm
2
8 pcs 16 pcs 27 pcs
ASD-WLP02-75N50 18 AWG/0.824 mm
2
6 pcs 12 pcs 18 pcs
ASD-WLP02-100N50 18 AWG/0.824 mm
2
4 pcs 8 pcs 13 pcs
Model
Linkable Quantities Depending on Voltage
110V 200V 277V
Cross-section
of linkable cable
ELECTRICAL SCHEMATIC DIAGRAM
+
-
DRIVER
L
N
G
L
N
G
L (live/hot) connect black
Ground connect green
FIXTURE
N (neutral) connect white
Power connector
120~277V 50/60 Hz
+
-
DRIVER
L (live/hot) connect black
Ground connect green
FIXTURE
N (neutral) connect white
+
-
DRIVER
L
N
G
FIXTURE
L
N
G
L
N
G
L
N
G
1. Remove screw and open the cover.
Affix gaskets ¾ (gaskets are not included
and should be purchased separately).
Insert power cord and cord going
to the next linking fixture.
2. Сonnect wires as in the picture below.
3. Close the cover and tighten screw.
Insert the cord from the first fixture into the
next fixture and connect the same way.
gasket
2.1.
3.
gasket
WALL MOUNT
1. Remove screw and open the cover.
2. Attach the rear cover to the wall
using wall dowels (not supplied,
should be bought separately).
3. Close the fixture and tighten screw.
2. 3.1.
WebSite: www.asd-lighting.com Fax: 339-502-8970
Phone: 781-739-3977E-mail: [email protected]
LED COB Cut-Off Wallpack
Standard Series
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

ASD STANDARD SERIES Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues