Enerco MR. HEATER 4000DF Manuel utilisateur

Catégorie
Chauffe-eau
Taper
Manuel utilisateur
OPERATING INSTRUCTIONS AND OWNER’S MANUAL
READ INSTRUCTIONS CAREFULLY: Read
and follow all instructions. Place instructions in
a safe place for future reference. Do not allow
anyone who has not read these instructions to
assemble, light, adjust or operate the heater.
MODEL
MODEL
3500DF 6000DF 3500DF 6000DF
07/11 Rev A 50125ENERCO GROUP, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 800-251-0001
DIRECT FIRED
PORTABLE HEATER
HEATSTAR
BY ENERCO
MR. HEATER
If the information in this manual is not followed exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
WARNING:
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
Service must be performed by a qualified service agency.
This is an unvented portable heater. It uses air (oxygen) from the area in which it is used. Adequate
combustion and ventilation air must be provided. Refer to page 5.
2
ENERCO GROUP, INC. |Direct Fired Portable Heater Operating Instructions and Owner’s Manual
WARNING:
FIRE, BURN, INHALATION, AND EXPLOSION HAZARD.
KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING MA-
TERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE
AWAY FROM THE HEATER AS RECOMMENDED BY THE
INSTRUCTIONS NEVER USE THE HEATER IN SPACES
WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE
COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE,
SOLVENTS, PAINT THINNER, DUST PARTICLES OR UN-
KNOWN CHEMICALS.
WARNING:
COMBUSTION BY-PRODUCTS PRODUCED WHEN US-
ING THIS PRODUCT CONTAIN CARBON MONOXIDE,
A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA
TO CAUSE CANCER AND BIRTH DEFECTS (OR OTHER
REPRODUCTIVE HARM).
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND
INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN
RESULT IN DEATH, SERIOUS BODILY INJURY AND
PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE,
EXPLOSION, BURN, ASPHYXIATION, CARBON MONOX-
IDE POISONING, AND/OR ELECTRICAL SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW
THE INSTRUCTIONS SHOULD USE OR SERVICE THIS
HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION
SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC.
CONTACT THE MANUFACTURER.
WARNING:
NOT FOR HOME OR RECREATIONAL VEHICLE USE
WARNING:
YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS,
SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU
OPERATE THIS HEATER.
The State of California requires the following warning:
CONTENTS
WARNINGS .................................................................................. 2
SPECIFICATIONS ........................................................................... 3
OPERATION ................................................................................. 4
SAFETY DEVICES .......................................................................... 4
MAINTENANCE ............................................................................ 5
TROUBLESHOOTING .................................................................... 6
WIRING DIAGRAMS ..................................................................... 7
PARTS LIST ................................................................................... 8
WARNING:
READ THE INSTRUCTIONS GIVEN IN THIS
MANUAL BEFORE USING THE APPLIANCE.
DO NOT USE GASOLINE, NAPHTHA OR VOLATILE
FUELS.
THE ELECTRICAL SYSTEM TO WHICH THE APPLIANCE
IS CONNECTED MUST COMPLY WITH ALL SAFETY
REGULATIONS IN FORCE. A RESIDUAL CURRENT
CIRCUIT BREAKER MUST BE PROVIDED ON THE MAIN
DISTRIBUTION BOARD.
UNPLUG THE HEATER BEFORE ATTEMPTING ANY
SERVICE OR MAINTENANCE.
ALWAYS CHECK THE POWER SUPPLY CABLE BEFORE
USE. IT MUST NOT BE BENT, CRUSHED, OR ANYWAY
DAMAGED.
THE POWER SUPPLY CABLE MUST BE REPLACED ONLY
BY QUALIFIED PERSONNEL.
ONLY USE AN ORIGINAL H07RN-F POWER CABLE
WITH WATERPROOF PLUG.
DO NOT TOUCH THE EXHAUST GAS OUTLET. DANGER
OF BURNS!
3
Operating Instructions and Owner’s ManualENERCO GROUP, INC. |Direct Fired Portable Heater
TECHNICAL SPECIFICATIONS
MH3500 DF
HS 3500DF
MH 6000DF
HS 6000DF
Heat input [kBTU/h] 360 600
Air Flow [cfm] 1795 2.800
Fuel Type Diesel/Kerosene/#1-2 Fuel Oil
Heat output [kBTU/h] - -
Fuel consumption
[gal/h] 2..6 4.32
[lb/h] 18.56 30.84
Power supply
Phase 1 1
Voltage [V] 120 120
Frequency [Hz] 60 60
Electric consumption
[W] 632 1,240
[A] 6.00 11.10
Nozzle [USgal/h] 2.00-80° S 3.00-80°S
Pump pressure [psi] 174 203
Max static pressure [in WC] - -
Recommended max. temp. in the air
duct
[°F] - -
Adjustment of combustion air Flap
[in] a=0.394 a=0.866
- -
Flue diameter [in] - -
Compulsory Flue draft [in WC] - -
Tank capacity [gal] 35.6 35.6
Dimensions, L x W x H [in] 56.4x26.38x38.3 68.5x28.8x44
Net Weight [lb] 153 243
IMPORTANT
Before using the heater, read and understand all instructions and
follow them carefully. The manufacturer is not responsible for
damages to goods or persons due to improper use of units.
GENERAL RECOMMENDATIONS
heater exhausts hot air and the combustion products into
the room, while those with indirect combustion are fitted
with a flue to take the fumes away through the chimney.
Always follow local ordinances and codes when using this
heater:
Read and follow this owner’s manual before using the
heater.
content.
materials (the minimum distance must be 6 ft.).
to the heater requirements. Direct combustion heaters
should only be used in well vented areas in order to avoid
carbon monoxide poisoning.
Never block air inlet (rear) or air outlet (front).
In case of very low temperatures add kerosene to the
heating oil.
Make sure heater is always under surveillance and keep
children and animals away from it;
Before starting the heater always check free rotation of
ventilator fan.
Unplug heater when not in use.
4
ENERCO GROUP, INC. |Direct Fired Portable Heater Operating Instructions and Owner’s Manual
Models X Y Z
3500 DF
0.157 in 0.098 in 0.157 in
6000 DF
0.157 in 0.098 in 0.157 in
the room where the heater is operated.
The air inlet and outlet must never be blocked for any
reason.
WARNING
DO NOT USE GASOLINE, NAPHTHA OR VOLATILE FUELS.
STOP HEATER BEFORE ADDING FUELS.
ALWAYS FILL OUTDOORS AWAY FROM OPEN FLAME
DO NOT USE EXTERNAL FUEL SOURCE.
DO NOT OPERATE HEATER WHERE FLAMMABLE LIQUIDS
OR VAPORS MAY BE PRESENT.
DO NOT START HEATER WHEN CHAMBER IS HOT
DO NOT START HEATER WHEN EXCESS FUEL HAS ACCUMU-
LATED IN THE CHAMBER.
DO NOT PLACE COOKING UTENSILS ON TOP OF THE
HEATER.
PLUG ELECTRICAL CORD INTO A PROPERLY GROUNDED
THREE-PRONG RECEPTACLE.
The generator can only work automatically when a control device,
such as for example a thermostat or a timer, is connected to the
generator. Connection to the generator is made by removing the
socket cover(4) and inserting the thermostat plug.
To start the machine you must:
If connected to the thermostat, turn the switch to (ON +
);
If not connected to the thermostat, turn the switch to (ON).
When unit is started for the first time or is started after the oil
tank has been totally emptied, the flow of oil to the burner may
be impaired by air in the circuit. In this case the control box will
cut out the heater and it might be necessary to renew the starting
procedure once or twice by depressing the reset button (1).
Should the heater not start, check that oil tank
is full and depress reset button (1).
Should the heater still not work, please refer to chapter
“OBSERVED FAULTS, CAUSES AND REMEDIES”.
STOPPING THE HEATER
Set main switch (3) on “0” position or turn thermostat or other
control device on lowest setting.
The flame goes out and the fan continues to work for approx.
90sec. cooling the combustion chamber.
SAFETY DEVICES
The unit is fitted with an electronic flame control box. In case of
malfunction this box will cut in and stop the heater, at the same
time the pilot lamp in the control box reset button (1) will light up.
Heaters are also equipped with an overheat thermostat safety
cutout which will stop the heater in case of overheating. This
thermostat will reset automatically but you will have to depress
button (1) on control box before being able to restart the heater.
TRANSPORT
WARNING
-
nate reason of overheating.
Before heater is moved it must be stopped and unplugged. Before
moving the heater wait till it has totally cooled off and make sure
oil tank cap is securely fixed.
1 4
O N
O N
0
3 2
5
1 RESET BUTTON WITH CONTROL LAMP
2 CONTROL LAMP
3 MAIN SWITCH
4 ROOM THERMOSTAT PLUG
5 POWER CORD
OPERATION
Before any attempt of starting the heater is made, check that
your electrical supply conforms to the data on the model plate.
Control Board
Gap of Electrodes
Clearances
The following minimum safety clearances from materials or objects
in the surroundings of the heater must be ensured:
Sides 2.5 ft. Air Inlet 2.5 ft.
Top 6 ft. Air outlet 12 ft.
X
Z
Y
5
Operating Instructions and Owner’s ManualENERCO GROUP, INC. |Direct Fired Portable Heater
The hot air generators with wheels must be wheeled. The
suspended version which has no wheels must be transported with
adequate machinery.
MAINTENANCE
Preventive and regular maintenance will ensure a long trouble free
life to your heater.
WARNING
Never service heater while it is plugged in, operating or hot.
Severe burns or electrical shock can occur.
Every 50 hours of operation: disassemble filter and wash with
clean oil, remove upper body parts and clean inside and ventilator
with compressed air, check correct attachment of H.V. connectors
to the electrodes and check H.V. cables, remove burner assembly,
clean and check electrode settings, adjust according to scheme
“GAP OF ELECTRODES”.
COLUMN INTENTIONALLY LEFT BLANK
6
ENERCO GROUP, INC. |Direct Fired Portable Heater Operating Instructions and Owner’s Manual
TROUBLESHOOTING
TROUBLE CAUSE SOLUTION
Motor does not start, no ignition
No electrical current Check mains (should be 120 V – 1~ – 60 Hz)
Check proper positioning and functioning of switch
Check fuse
Wrong setting of room ther-
mostat or other control
Check correct setting of heater control. If thermostat, make
sure selected temperature is higher than room temperature
Thermostat or other control
defective
Replace control device
Electrical motor defective Replace electrical motor
Electrical motor bearings
defective
Replace electrical motor bearings
Burned out condenser Replace condenser
Motor starts, no ignition or cuts out
Electric ignitor defective Check connection of H.V. Ieads to electrodes and transformer
Check electrodes setting (see scheme “GAP OF ELECTRODES”)
Check electrodes for cleanliness
Replace H.V. transformer
Flame control box defective Replace control box
Photocell defective Clean or replace photocell
Not enough or no fuel at all
at burner
Check state of motor-pump plastic coupling
Check fuel line system including fuel filter for possible leaks
Clean or replace oil nozzle
Solenoid defective Check electrical connection
Check thermostat LI
Clean or replace solenoid
Motor starts, heater emits smoke
Not enough combustion air Make sure air inlet and outlet are free
Check setting of combustion air flap
Clean burner disc
Too much combustion air Check setting of combustion air flap
Fuel contaminated or con-
tains water
Drain fuel in tank with clean fuel
Clean oil filter
Air leaks in fuel circuit Check the seals on the ducts and the diesel filter
Not enough fuel at burner Check pump pressure
Clean or replace fuel nozzle
Too much fuel at burner Check pump pressure
Replace nozzle
Heater does not stop
Solenoid Replace solenoid coil or complete solenoid
If heater still not working properly, please revert to nearest authorized dealer.
7
Operating Instructions and Owner’s ManualENERCO GROUP, INC. |Direct Fired Portable Heater
WIRING DIAGRAM
3500 SERIES MODELS
FU Fuse 20A
IT Transformer H.V.
LI1 Overheat Thermostat
EV1 Solenoid Valve 1°
FO Photocell
CO Condenser
MV Fan Motor
ST Electric pilot
RV Control
TA Room Thermostat
RE Relays
AP Control Box
PA Air pressure control
RF Heater Filter
FUA Fan thermostat
PE Ground
DRAWING LEGEND
6000 SERIES MODELS
120V - 1~ - 60Hz
PL 10/07
25
27
29
03
A
05
08
09
46
17
10
06
30
12
20
11
57
19
33
32
45
18
22
23
21
19
24
26
28
35
31
36
44
42
85
14
82
84
83
76
75
B
65
66
67
69
68
51
52
53
56
58
63
64
59
90
77
78
76
70
72
74
71
73
79
91
92
93
94
95
96
3500DF
100
98
99
101
94
102
01
103
16
14
17
14
13
86
108
107
87
106
104
105
14
16
14
A
33
B
Optional
15
8
Operating Instructions and Owner’s ManualENERCO GROUP, INC. |Direct Fired Portable Heater
HS-MH3500DF Heater Parts List BM2
NO. HS# BM2 # DESCRIPTION NO. HS# BM2 # DESCRIPTION
01 40493 G06408-9010 Outlet Cone 59 50319 E10930 Transformer HT BRHAMA
03
50446 G06230
Combustion Chamber
63 50320 E40124 Control Box BRAHMA
05
50447 G06233-9010
Upper Body
64 50014 G06073 Plate for Elect. Components
06
40494 G06409-9010
Lower Body
65 50013 E10102-P Switch On-Off
08
50160 E10678-110 Motor 450W with Condenser 66 50570 E20640 Thermostat Plug 3P+T
09
50161 E11230 Condenser 40µF 67 50011 E20665 Thermostat Cap
10
50163 G06125-9010
Motor Flange
68 50009 E30443 Elect. Wire w/Plug and Fastener
11
50165 T10260 Fan Blade ø350 18° 69 50008 E11030 Lamp 120V
12
50167 P30169
Inlet Grill 70
50321 T20357 Nozzle 2.00 GPH 80° W
13 50051 I40330 Tube BP 1/4"FF L.420mm
71
50126 G01077
Turbo Disc
14 50052 I20104 Nipple FE 1/4"mm 72 50440 I33005 Nozzle Support
15 50410 02AC513 Oil Filter Pre-Heater 1/4"
73
50425 G06228
Burner Flange ø 102mm
16 50054 G06104-9005 Filter Support 74 50131 I31034 Nut M14
17 50055 I40329 Tube BP 1/4"FF L.260mm 76 50133 I40192 Micropipe
18 50056 P20176-9005 Handle 77 50134 E10215 Electrode
19 40477 C30355 Plug ø25
78
50322 G02078 H.T. Cables 90° BRAHMA
20
50058 P20177-9005
Foot
79 50323 E50328 Photo Cell
21 50060 I40331 Tube BP 1/4"F L. 580mm
82
50442 T20410-1 Pump Danfoss BFP 21-R3
22
50061 I30696 Pick-upTube L. 220mm 83 50140 T20118 Solenoid Spool Danfoss
23 50063 I30737 Nipple 1/4"m-m12x1.75m 84 50141 T20117 Solenoid Valve Danfoss
24 50064 G06068-9005 Power Lead Hook
85
50195 E10513 Coupling K1
25
50170 G06127-9005 Fuel Tank 105 liters 86 50144 T20241 O-Ring Kit Oil Filter
26 50070 C30367 Fuel Cap 87 50145 T20242 Filter Cartridge
27 50067 G06129-9005 Wheel Axle 90 50325 E20418 Stop Button Protection
28
50068 G06106-9005
Wheel Axle Support
91 50336 E50327 Photo Cell Holder
29 50071 C10546 Wheel 260-25 92 40492 G06406-9010 Photo Cell Mounting Plate
30 50072 M20202 Spring Washer 93 50337 E50441 Pressure Switch 100Pa
31 50073 I25020 Drain Plug 94 50431 I40335 Silicone Pipe ø4x8
32 40479 C30375 O-Ring ø16 x 2.62 95 50429 I31131 Connection Straight ø6
33
50434 G00248
Electrical Components Dwr
96 50433 T20442 Solenoid Valve Cable
35 50077 P50127 Control Box Cover
98 50450 G06266 Blast Tube
36
40495 G06410-9010
Base 99 50413 E20671 Terminal Board
42 50057 C30319
Rubber Tap
100 50419 G06183 Air Regulation Flap
44 50411 C30372 Cable Protection ø35
101 50081 I20325 Connection 1/8"
45 50085 E50102 Limit Thermostat
102 50079 I31130 Connection Straight ø6 1/8"
46 50086 G06072 Sleeve ø8 x ø6 x 9.5
103 50024 T20201 Oil Filter 1/4"
51 50246 G06153 Electrial Components Dwr.
104 50025 T20234 O-Ring Kit Oil Filter
52 50093 E20508 Fuse Holder
105 50130 T20206 Filter Cartridge
53 50092 E10313 Fuse (6x30) 20A
106 50251 T20212 Filter Housing
56 50096 E20319 Terminal Board
107 50082 E20953 Cable Holder PG11
57 50097 E11125 Relay Finder 65.31 AC
108 50083 E20954 Ring Nut PG11
58 50098 E20305 Terminal Board
7/13/2011
9
Operating Instructions and Owner’s ManualENERCO GROUP, INC. |Direct Fired Portable Heater
PL 10/07
25
27
29
03
A
05
15
08
09
46
17
10
06
01
04
30
12
20
11
16
14
17
14
13
57
19
33
32
45
18
22
23
21
19
24
26
28
35
31
36
44
42
86
87
07
85
14
82
84
83
76
75
B
65
66
67
69
68
51
52
53
56
58
63
64
59
90
77
78
76
70
72
74
71
73
79
91
92
93
94
95
96
6000DF
100
98
99
101
94
102
A
15
33
B
10
Operating Instructions and Owner’s ManualENERCO GROUP, INC. |Direct Fired Portable Heater
HS6000DF SERIES DIRECT FIRED HEATER PARTS LIST 2011
Ref. # Part # BM2 #
Discription
Ref. # Part # BM2 #
Discription
01
50027 G06139-9010
Outlet cone
53 50092 E10313
Fuse 20A
03
50460 G06232
Combustion chamber 56 50096 E20319 Terminal board
04
50037 G06143-9010
Protection 57 50097 E11125 Relay
05
50461 G06235-9010
Upper Body 58 50098 E20305 Terminal board
06
50462 G06238-9010
Lower body 59 50099 E10917-2 High voltage transfomer Cofi
07
40519 G06397
A
ir flap
63 50320 E40124 Control box Brahma TGRD 91
08 50454 E10704-110 Motor 750W w/condensor 64 50014 G06073 Support plate
09 50455 E11249 Condensor 80µF 65 50013 E10102-P Switch
10 50463 G06239-9010 Motor flange 66 50012 E20640 Thermostat socket 3P+T
11
50049 T10263
Fan 500 18°
67 50011 E20665 Thermostat jumper plug
12 50050 P30129
Inlet grille
68 50009 E30443 Electrical plug
13 50051 I40330 Tube BP 1/4"FF 420mm 69 50008 E11030 Lamp 110v
14 50052 I20104
Nipple FE 1/4"mm
70 50006 T20327 Nozzle 3.00 GPH 80°S
15 50053 T20239
Oil filter heated
71 50465 G07025 Turbo disc
16 50054 G06104-9005
Filter support
72 50440 I33005 Nozzle support
17 50055 I40329 Tube BP 1/4"FF 260mm 73 50459 G06229 Burner flange ø102mm
18 50056 P20176-9005
Handle
74 50131 I31034 Nut M14
19 40477 C30355
Plug ø25
76 50133 I40192 Micropipe
20
50059 P20180-9005
Foot 77 50134 E10215 Electrode
21 50060 I40331 Tube BP 1/4" F 580mm 78 50135 G02076 High voltage leads 90°
22
50466 I30698
Tube L 290mm 79 50323 E50328 Photo cell FC13
23 50063 I30737 Nipple 1/4"m 12x1 75m 82 50139 T20411-1 Pump assy Danfoss BFP 21 R5
24 50064 G06068-9005
Power lead hoo
k
83 50140 T20118 Solenoid, coil Danfoss
25
50457 G06146-9005
Tank 135 liters
84 50141 T20117 Solenoid, valve NC
26 50070 C30367
Fuel cap
85
50143
E10514 Coupling, pump to motor
27 50067 G06129-9005
A
xle
86 50144 T20241
O-ring kit for filter
28
50456 G06107-9005
Axle support
87 50145 T20242
Filter cartridge
29 50071 C10546 Wheel 260-25 90
50325
E20418 Stop button protection
30 50072 M20202
Spring washer ø25
91 50336 E50327 Photo cell holder
31 50428 I25020
Drain plug
92 40492 G06406-9010
mounting plate for pressure sw
32 40479 C30375
O-ring ø16 x 2.62
93 50337 E50441
Pressure switch
33 50075 G00215
Elect. component drawer
94 40501 I40335
Silicon pipe ø4x8
35 50077 P50127 Control box cover
95 50429 I31131
Stright connectonr ø6
36 40496 G06411-9010 Base
96 50433 T20442
Solenoid valve cabl
e
42 50453 C30323
Cable protection ø10
98 40497 G06412
Blast tube
44 50084 C30307
Ring protector
99 50413 E20671
Terminal board
45 50085 E50102
High limit sensor
100 50419 G06183
A
ir regulation flap
46 50086 G06072
Sleeve spacers
101 50081 I20325
connection 1/8"
51 50246 G06153
Elect. component dwr.
102 50079 I31130
Connector straight ø6 1/8"
52 50093 E20508 Fuse holder
11
Operating Instructions and Owner’s ManualENERCO GROUP, INC. |Direct Fired Portable Heater
12
ENERCO GROUP, INC. |Direct Fired Portable Heater Operating Instructions and Owner’s Manual
OPERATING INSTRUCTIONS AND OWNER’S MANUAL
READ INSTRUCTIONS CAREFULLY: Read
and follow all instructions. Place instructions in
a safe place for future reference. Do not allow
anyone who has not read these instructions to
assemble, light, adjust or operate the heater.
MODEL
MODEL
HEATSTAR
BY ENERCO
MR. HEATER
ENERCO GROUP, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 800-251-0001
Mr. Heater is a registered trademark of Enerco Group, Inc.
© 2004, ENERCO GROUP, INC. All rights reserved
WARNING:
USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS
COULD CAUSE INJURY OR DEATH. REPLACEMENT PARTS ARE ONLY AVAILABLE
DIRECT FROM THE FACTORY AND MUST BE INSTALLED BY A QUALIFIED SERVICE
AGENCY.
PARTS ORDERING INFORMATION:
PURCHASING: Accessories may be purchased at any Mr. Heater/HeatStar local dealer
or direct from the factory
FOR INFORMATION REGARDING SERVICE
Please call Toll-Free 800-251-0001 • www.enerco-mrheater.com
Our office hours are 8:30 AM – 5:00 PM, EST, Monday through Friday.
Email to: techservice@enerco-mrheater.com
Please include the model number, date of purchase, and description of problem in all
communication.
LIMITED WARRANTY
The company warrants this product to be free from imperfections in material or workmanship,
under normal and proper use in accordance with instructions of The Company, for a period
of one year from the date of delivery to the buyer. The Company, at its option, will repair or
replace products returned by the buyer to the factory, transportation prepaid within said one
year period and found by the Company to have imperfections in material or workmanship.
If a part is damaged or missing, call our Technical Support Department at 800-251-0001.
Address a
ny Warranty Claims to the Service Department, Enerco Group, Inc., 4560 W. 160TH
ST., Cleveland, Ohio 44135. Include your name, address and telephone number and include
details concerning the claim. Also, supply us with the purchase date and the name and address
of the dealer from whom you purchased our product.
The foregoing is the full extent of the responsibility of the Company. There are no other
warranties, express or implied. Specifically there is no warranty of fitness for a particular
purpose and there is no warranty of merchantability. In no event shall the Company be liable for
delay caused by imperfections, for consequential damages, or for any charges of the expense
of any nature incurred without its written consent. The cost of repair or replacement shall be
the exclusive remedy for any breach of warranty. There is no warranty against infringement of
the like and no implied warranty arising from course of dealing or usage of trade. This warranty
will not apply to any product which has been repaired or altered outside of the factory in any
respect which in our judgment affects its condition or operation.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so
the above limitation or exclusion may not apply to you. This Warranty gives you specific legal
rights, and you may have other rights which vary from state to state.
Enerco Group, Inc.
reserves the right to make changes at any time, without notice or
obligation, in colors, specifications, accessories, materials and models.
07/08 #50125
4000DF 6000DF 4000DF 6000DF
MODÈLE
LISEZ SOIGNEUSEMENT LES INSTRUCTIONS :
Lisez et observez toutes les instructions. Conservez
les instructions pour vous y référer ultérieurement.
Interdisez à quiconque n’ayant pas lu les présentes
instructions d’assembler, d’allumer, de régler ou de
faire fonctionner cet appareil de chauffage.
GUIDE D’UTILISATION ET INSTRUCTIONS DE FONCTIONNEMENT
MR. HEATER
HEATSTAR
BY ENERCO
MODÈLE
ENERCO GROUP, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 É.-U. • 800-251-0001
Mr. Heater et HeatStar sont des marques de commerce déposées de Enerco Group, Inc.
© 2003, Enerco Group Inc. Tous droits réservés.
AVERTISSEMENT:
N’UTILISEZ QUE LES PIÈCES DE REMPLACEMENT DU FABRICANT. IL EST POSSIBLE
DE SE PROCURER CES PIÈCES DIRECTEMENT DE L’USINE OU PAR L’ENTREMISE DES
DÉTAILLANTS LOCAUX MR. HEATER/HEATSTAR.
INFORMATIONS SUR LA COMMANDE DE PIÈCES :
ACHAT : On peut se procurer les accessoires par l’entremise de tous les détaillants
locaux Mr. Heater/HeatStar ou directement du fabricant
POUR OBTENIR DES INFORMATIONS SUR LE SERVICE
Appelez sans frais au 800-251-0001 • www.enerco-mrheater.com
Nos heures d’ouverture sont de 8 h 30 à 17 h HNE, du lundi au vendredi.
Adressez vos courriels à : techservice@mrheater.com
Veuillez indiquer le numéro du modèle, la date d’achat et la description du problème
dans toutes vos communications avec nous.
GARANTIE LIMITÉE
L’entreprise garantit ce produit contre tout défaut de matériel ou de main-d’œuvre, dans des
conditions d’utilisation normale et adéquate, conformément aux instructions de l’entreprise,
pour une période d’un an à compter de la date de livraison à l’acheteur. L’entreprise réparera ou
remplacera, à sa discrétion, les produits retournés port payé par l’acheteur au fabricant dans la
période d’un an et jugés par l’entreprise comme présentant des défauts de matériel ou de main-
d’œuvre.
Si une pièce est endommagée ou manquante, téléphonez à notre service de soutien technique
au 800-251-0001.
Adressez toute réclamation relative à la garantie à Service Department, Enerco Group, Inc., 4560
W. 160TH ST., Cleveland, Ohio 44135 États-Unis. Indiquez vos nom, adresse et numéro de téléphone
ainsi que les détails de la réclamation. Indiquez-nous également la date d’achat et le nom et l’adresse
du détaillant de qui vous avez acheté le produit.
Ce qui est énoncé ci-dessus constitue la responsabilité totale de l’entreprise. Il n’existe aucune autre
garantie, expresse ou tacite. Plus précisément, il n’y a aucune garantie concernant l’adéquation à une
utilisation particulière ni aucune garantie concernant la qualité marchande. En aucun cas l’entreprise
ne sera tenue responsable des retards causés par des défectuosités, ni des dommages indirects,
ni des dépenses encourues sans son consentement écrit, quelle que soit leur nature. Le coût de la
réparation ou du remplacement sera le seul recours possible en cas de violation de garantie. Il n’y
a aucune garantie contre une transgression de ce genre ni aucune garantie tacite découlant des
usages du commerce ou de la façon habituelle d’échanger. La présente garantie ne s’applique à
aucun produit qui a été réparé ou modifié par d’autres que le fabricant si cela influe de quelque
façon que ce soit sur l’état de l’appareil ou son fonctionnement, selon notre jugement.
Certains États ou provinces ne permettent pas d’exclure ou de limiter les dommages indirects ou
subséquents. Par conséquent, les limitations ou exclusions ci-dessus mentionnées ne vous concernent
peut-être pas. La présente garantie vous accorde des droits juridiques précis, mais vous pourriez
avoir d’autres droits qui varient selon la province ou l’État.
Enerco Group Inc. se réserve le droit d’effectuer des modifications en tout temps, sans préavis ni
obligation, aux couleurs, aux spécifications, aux accessoires, aux matériaux et aux modèles.
4000DF 6000DF
4000DF 6000DF
07/08 #50125ENERCO GROUP, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 800-251-0001
HS6000DF SERIES DIRECT FIRED HEATER PARTS LIST 2011
Ref. # Part # BM2 #
Discription
Ref. # Part # BM2 #
Discription
01
50027 G06139-9010
Outlet cone
53 50092 E10313
Fuse 20A
03
50460 G06232
Combustion chamber 56 50096 E20319 Terminal board
04
50037 G06143-9010
Protection 57 50097 E11125 Relay
05
50461 G06235-9010
Upper Body 58 50098 E20305 Terminal board
06
50462 G06238-9010
Lower body 59 50099 E10917-2 High voltage transfomer Cofi
07
40519 G06397
A
ir flap
63 50320 E40124 Control box Brahma TGRD 91
08 50454 E10704-110 Motor 750W w/condensor 64 50014 G06073 Support plate
09 50455 E11249 Condensor 80µF 65 50013 E10102-P Switch
10 50463 G06239-9010 Motor flange 66 50012 E20640 Thermostat socket 3P+T
11
50049 T10263
Fan 500 18°
67 50011 E20665 Thermostat jumper plug
12 50050 P30129
Inlet grille
68 50009 E30443 Electrical plug
13 50051 I40330 Tube BP 1/4"FF 420mm 69 50008 E11030 Lamp 110v
14 50052 I20104
Nipple FE 1/4"mm
70 50006 T20327 Nozzle 3.00 GPH 80°S
15 50053 T20239
Oil filter heated
71 50465 G07025 Turbo disc
16 50054 G06104-9005
Filter support
72 50440 I33005 Nozzle support
17 50055 I40329 Tube BP 1/4"FF 260mm 73 50459 G06229 Burner flange ø102mm
18 50056 P20176-9005
Handle
74 50131 I31034 Nut M14
19 40477 C30355
Plug ø25
76 50133 I40192 Micropipe
20
50059 P20180-9005
Foot 77 50134 E10215 Electrode
21 50060 I40331 Tube BP 1/4" F 580mm 78 50135 G02076 High voltage leads 90°
22
50466 I30698
Tube L 290mm 79 50323 E50328 Photo cell FC13
23 50063 I30737 Nipple 1/4"m 12x1 75m 82 50139 T20411-1 Pump assy Danfoss BFP 21 R5
24 50064 G06068-9005
Power lead hoo
k
83 50140 T20118 Solenoid, coil Danfoss
25
50457 G06146-9005
Tank 135 liters
84 50141 T20117 Solenoid, valve NC
26 50070 C30367
Fuel cap
85
50143
E10514 Coupling, pump to motor
27 50067 G06129-9005
A
xle
86 50144 T20241
O-ring kit for filter
28
50456 G06107-9005
Axle support
87 50145 T20242
Filter cartridge
29 50071 C10546 Wheel 260-25 90
50325
E20418 Stop button protection
30 50072 M20202
Spring washer ø25
91 50336 E50327 Photo cell holder
31 50428 I25020
Drain plug
92 40492 G06406-9010
mounting plate for pressure sw
32 40479 C30375
O-ring ø16 x 2.62
93 50337 E50441
Pressure switch
33 50075 G00215
Elect. component drawer
94 40501 I40335
Silicon pipe ø4x8
35 50077 P50127 Control box cover
95 50429 I31131
Stright connectonr ø6
36 40496 G06411-9010 Base
96 50433 T20442
Solenoid valve cabl
e
42 50453 C30323
Cable protection ø10
98 40497 G06412
Blast tube
44 50084 C30307
Ring protector
99 50413 E20671
Terminal board
45 50085 E50102
High limit sensor
100 50419 G06183
A
ir regulation flap
46 50086 G06072
Sleeve spacers
101 50081 I20325
connection 1/8"
51 50246 G06153
Elect. component dwr.
102 50079 I31130
Connector straight ø6 1/8"
52 50093 E20508 Fuse holder
11
Operating Instructions and Owner’s ManualENERCO GROUP, INC. |Direct Fired Portable Heater
PL 10/07
25
27
29
03
A
05
15
08
09
46
17
10
06
01
04
30
12
20
11
16
14
17
14
13
57
19
33
32
45
18
22
23
21
19
24
26
28
35
31
36
44
42
86
87
07
85
14
82
84
83
76
75
B
65
66
67
69
68
51
52
53
56
58
63
64
59
90
77
78
76
70
72
74
71
73
79
91
92
93
94
95
96
6000DF
100
98
99
101
94
102
A
15
33
B
10
Operating Instructions and Owner’s ManualENERCO GROUP, INC. |Direct Fired Portable Heater
HS-MH3500DF Heater Parts List BM2
NO. HS# BM2 # DESCRIPTION NO. HS# BM2 # DESCRIPTION
01 40493 G06408-9010 Outlet Cone 59 50319 E10930 Transformer HT BRHAMA
03
50446 G06230
Combustion Chamber
63 50320 E40124 Control Box BRAHMA
05
50447 G06233-9010
Upper Body
64 50014 G06073 Plate for Elect. Components
06
40494 G06409-9010
Lower Body
65 50013 E10102-P Switch On-Off
08
50160 E10678-110 Motor 450W with Condenser 66 50570 E20640 Thermostat Plug 3P+T
09
50161 E11230 Condenser 40µF 67 50011 E20665 Thermostat Cap
10
50163 G06125-9010
Motor Flange
68 50009 E30443 Elect. Wire w/Plug and Fastener
11
50165 T10260 Fan Blade ø350 18° 69 50008 E11030 Lamp 120V
12
50167 P30169
Inlet Grill 70
50321 T20357 Nozzle 2.00 GPH 80° W
13 50051 I40330 Tube BP 1/4"FF L.420mm
71
50126 G01077
Turbo Disc
14 50052 I20104 Nipple FE 1/4"mm 72 50440 I33005 Nozzle Support
15 50410 02AC513 Oil Filter Pre-Heater 1/4"
73
50425 G06228
Burner Flange ø 102mm
16 50054 G06104-9005 Filter Support 74 50131 I31034 Nut M14
17 50055 I40329 Tube BP 1/4"FF L.260mm 76 50133 I40192 Micropipe
18 50056 P20176-9005 Handle 77 50134 E10215 Electrode
19 40477 C30355 Plug ø25
78
50322 G02078 H.T. Cables 90° BRAHMA
20
50058 P20177-9005
Foot
79 50323 E50328 Photo Cell
21 50060 I40331 Tube BP 1/4"F L. 580mm
82
50442 T20410-1 Pump Danfoss BFP 21-R3
22
50061 I30696 Pick-upTube L. 220mm 83 50140 T20118 Solenoid Spool Danfoss
23 50063 I30737 Nipple 1/4"m-m12x1.75m 84 50141 T20117 Solenoid Valve Danfoss
24 50064 G06068-9005 Power Lead Hook
85
50195 E10513 Coupling K1
25
50170 G06127-9005 Fuel Tank 105 liters 86 50144 T20241 O-Ring Kit Oil Filter
26 50070 C30367 Fuel Cap 87 50145 T20242 Filter Cartridge
27 50067 G06129-9005 Wheel Axle 90 50325 E20418 Stop Button Protection
28
50068 G06106-9005
Wheel Axle Support
91 50336 E50327 Photo Cell Holder
29 50071 C10546 Wheel 260-25 92 40492 G06406-9010 Photo Cell Mounting Plate
30 50072 M20202 Spring Washer 93 50337 E50441 Pressure Switch 100Pa
31 50073 I25020 Drain Plug 94 50431 I40335 Silicone Pipe ø4x8
32 40479 C30375 O-Ring ø16 x 2.62 95 50429 I31131 Connection Straight ø6
33
50434 G00248
Electrical Components Dwr
96 50433 T20442 Solenoid Valve Cable
35 50077 P50127 Control Box Cover
98 50450 G06266 Blast Tube
36
40495 G06410-9010
Base 99 50413 E20671 Terminal Board
42 50057 C30319
Rubber Tap
100 50419 G06183 Air Regulation Flap
44 50411 C30372 Cable Protection ø35
101 50081 I20325 Connection 1/8"
45 50085 E50102 Limit Thermostat
102 50079 I31130 Connection Straight ø6 1/8"
46 50086 G06072 Sleeve ø8 x ø6 x 9.5
103 50024 T20201 Oil Filter 1/4"
51 50246 G06153 Electrial Components Dwr.
104 50025 T20234 O-Ring Kit Oil Filter
52 50093 E20508 Fuse Holder
105 50130 T20206 Filter Cartridge
53 50092 E10313 Fuse (6x30) 20A
106 50251 T20212 Filter Housing
56 50096 E20319 Terminal Board
107 50082 E20953 Cable Holder PG11
57 50097 E11125 Relay Finder 65.31 AC
108 50083 E20954 Ring Nut PG11
58 50098 E20305 Terminal Board
9
Operating Instructions and Owner’s ManualENERCO GROUP, INC. |Direct Fired Portable Heater
PL 10/07
25
27
29
03
A
05
08
09
46
17
10
06
30
12
20
11
57
19
33
32
45
18
22
23
21
19
24
26
28
35
31
36
44
42
85
14
82
84
83
76
75
B
65
66
67
69
68
51
52
53
56
58
63
64
59
90
77
78
76
70
72
74
71
73
79
91
92
93
94
95
96
3500DF
100
98
99
101
94
102
01
103
16
14
17
14
13
86
108
107
87
106
104
105
14
16
14
A
33
B
Optional
15
8
Operating Instructions and Owner’s ManualENERCO GROUP, INC. |Direct Fired Portable Heater
7
Le fait de Faire marcher des Instructions et le Manuel de PropriétaireENERCO GROUP, INC. |Chauffage Portatif Direct-tiré
WIRING DIAGRAM
FU Fusible 20A
IT Transformateur H.T.
LI1 Thermostat de surchauffe
EV1 Electrovanne 1°
FO Photoresistance
CO Condensateur
MV Moteur du ventilator
ST Lampe temoin d’alimentation
RV Commutateur
TA Prise thermostat dambiace
RE Relais
AP Coffret de securite
FUA Fusible 6.3A
PA Connecteur
RF Pressostats Air
PE Terre
DESSIN DE LA LÉGENDE
3500 SERIES MODELS
6000 SERIES MODELS
120V - 1~ - 60Hz
6
ENERCO GROUP, INC. |Chauffage Portatif Direct-tiré Le fait de Faire marcher des Instructions et le Manuel de Propriétaire
ANOMALIES DE FONCTIONNEMENT CAUSES ET SOLUTIONS
ANOMALIE
DEFONCTIONNEMENT
CAUSE SOLUTION
Le ventilateur ne démarre pas et
la flamme ne s’allume pas
Le courant électrique n’arrive pas Vérifier les caractéristiques de l’installation electrique (120 V – 1~ – 60 Hz)
Vérifier le fonctionnement et la position de i’interrupteur
Vérifier l’efficacité du fusible
Mauvais réglage d’unéventuel
dispositif de contrôle
Vérier que le réglage du dispositif de contrôle soit correct (par ex. la
température choisie sur le thermostat doitêtre supérieureà la température
du local)
Dispositif de contrôle défectueux Remplacer le dispositif de contrôle
Bobinage du moteur brûlé ou
interrompu
Remplacer le moteur
Roulements du moteur bloqués Remplacer les roulements
Condensateur du moteur brûlé Remplacer le condensateur
Le ventilateur démarre et la
flamme ne s’allume pas ou ne
reste pas allumée
L’allumage ne fonctionne pas Vérier les branchements des câbles d’allumage aux électrodes et au
transformateur
Vérifier la position des électrodes et leur distance selon le schéma “TROU
DES ELECTRODES”
Vérifier que lesélectrodes soient propres
Remplacer le transformateur d’allumage
Le coffret de contrôle de la amme
défectueux
Remplacer le coffret
La cellule photo ne fonctionne pas Nettoyer la cellule photo ou la remplacer
Le fuel n’arrive pas au brûleur ou
arrive en quantité insuffisante
Contrôler l’efcacité du raccord moto-pompe
Contrôler qu’il n’y ait pas d’inltrations d’air dans le circuit du fuel en
vérifiant l’étanchéité des tuyaux et desjoints du filtre
Nettoyer ou s’il le faut changer le gicleur
L’électro-vanne ne fonctionne pas Contrôler le branchement électrique
Contrôler le thermostat LI
Nettoyer etéventuellement remplacer l’électrovanne
Le ventilateur démarre et la
flamme s’allume en produisant
de la fumée
L’air de combustion est insuffisant Enlever tous les obstacles ou obstructions à l’aspiration ouà la sortie de l’air
Vérifier la position du volet de réglage de l’air
Nettoyer le disque du brûleur
L’air de combustion est excessif Vérifier la position du volet de réglage de l’air
Le fuel utilisé est sale ou contient de
l’eau
Vidanger et remplacer par du fuel propre
Nettoyer le filtre du fuel
Infiltrations d’air dans le circuit du
fuel
Vérifier l’étanchéité des tuyaux et du filtreà fuel
Quantité insuffisante de fuel au
brûleur
Vérifier la valeur de la pression de la pompe
Nettoyer et remplacer le gicleur
Quantité excessive de fuel au brûleur Vérifier la valeur de la pression de la pompe
Subtituer le gicleur
Le générateur ne s’arrête pas
L’électrovanne ne ferme pas Remplacer le corps de l’électrovanne
Si ces contrôles et ces solutions ne sont pas la cause du mauvais fonctionnement du générateur, veuillez contacter notre plus proche centre
de vente – assistance autorisé
5
Le fait de Faire marcher des Instructions et le Manuel de PropriétaireENERCO GROUP, INC. |Chauffage Portatif Direct-tiré
surchauffe: le thermostat se réarme automatiquement quand
la température de la chambre de combustion diminue jusqu’à
rejoindre la valeur maximale admise. Avant de remettre en marche
le générateur il faut trouver et éliminer la cause qui a produit la
surchauffe (par ex. obstruction de l’entrée ou de la sortie de l’air,
arrêt du ventilateur). Pour faire redémarrer le générateur il faut
pousser le bouton de réarmement (1) et répéter les instructions
spécifiques du paragraphe “MISE EN MARCHE”.
TRANSPORT ET DEPLACEMENT
ATTENTION
Avant de déplacer lappareil il faut:
Arrêter le générateur en suivant les indications du para-
graphe “ARRET”;
Débrancher l’alimentation en enlevant la che de la prise de
courant;
Attendre que le générateur soit froid.
Avant de soulever ou de déplacer le générateur il faut s’assurer
que le bouchon du réservoir soit bien fixé.
Le générateur peut être fourni dans une version mobile, muni de
roues, ou dans une version suspendue, monté sur une structure
de support avec des ancrages pour le fixage qui doit être effectué
avec l’aide de cordes ou de chaines. Dans le premier cas, pour le
transport il est suffisant de saisir le générateur par la poignée de
soutien et de le faire glisser sur les roues. Dans le deuxième cas
le soulèvement doit être effectué avec un chariot élévateur ou un
équipement similaire.
ENTRETIEN
Pour que l’appareil fonctionne régulièrement, il est nécessaire de
nettoyer périodiquement la chambre de combustion, le brûleur et
le ventilateur.
ATTENTION
Avant de commencer une quelconque opération d’entretien
il faut:
Arrêter le générateur selon les indications du paragraphe
ARRET”;
Débrancher l’alimentation électrique en enlevant la che de
la prise de courant;
Attendre que le générateur soit froid.
Toutes les 50 heures de fonctionnement il est nécessaire de:
Démonter la cartouche du ltre, l’extraire et la nettoyer avec
du fuel propre;
Démonter la carrosserie externe cylindrique et nettoyer la
partie interne et les pales du ventilateur;
•Contrôler l’état des câbles et des connexions haute tension
sur les électrodes;
Démonter le brûleur et en nettoyer les différentes parties,
nettoyer les électrodes et régler leur distance en respectant
les données du schéma “TROU DES ELECTRODES”.
LA COLONNE A INTENTIONNELLEMENT
QUITTÉ LE BLANC
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Enerco MR. HEATER 4000DF Manuel utilisateur

Catégorie
Chauffe-eau
Taper
Manuel utilisateur

dans d''autres langues