DO NOT USE EQUIPMENT BEFORE READING THIS SECTION
WARN
IN
HIGH PRESSURE SPRAY
CAN CAUSE SERIOUS INJURY
Maximum Working Pressure 3000 psi,
21
0 bar
An airless spray gun requires that fluid
be introduced to it
at
very high pressure.
Fluids under liigh pressure, from spray
or
leaks, can penetrate the skin and inject
substantial quantities
of
toxic fluid into
the body.
If
not promptly and properly
treated, the injury can cause tissue death
or
gangrene and may result in serious,
permanent disability
or
amputation
of
the
wounded part. Therefore, extreme
caution must be exercised when using
any airless spray equipment.
IF YOU
ARE
INJECTED, SEE A PHYSICIAN
IMMEDIATELY. DO
NOT
TREAT
AS
A
SIMPLE CUT!
NOTE
TO PHYSICIAN: Injection into
the skin is a serious, traumatic injury.
It is
important to treat the injury
surgically
as
soon as possible. Do not delay treatment
to research toxicity. Toxicity is a concern
with some exotic coatings injected
directly into the bloodstream.
Consultation with a plastic surgeon
or
a
reconstructive hand surgeon may be
advised.
1) Handle the spray gun
carefully.
Keep clear of the nozzle. NEVER point
the gun at yourself
or
anyone else.
NEVER permit any part of
your
body to
come
in
contact with the fluid stream of
either the gun
or
any hose leak.
ALWAYS
keep the gun trigger safety
lever
in
a locked position when not
spraying.
ALWAYS
use a tip safety
guard.
2) NEVER attempt to force the flow
of
fluid backward through the gun with your
finger, hand or hand-held object against
the gun nozzle.
THIS IS
NOT
AN
AIR
SPRAY
GUN.
3) NEVER attempt to remove tip,
disassemble or repair equipment without
first doing the
following:
4) Before flushing system, always
PRESSURE
RELEASE
PROCEDURE
A.
Set
trigger
safety
in
a
locked
position.
B.
Shut
off
pump
and
unplug
electrical
cord.
C.
Release
fluid
pressure
from
entire
system
and
trigger
gun.
D.
Reset
trigger
safety
in
a
locked
position.
remove spray tip and adjust fluid
pressure to lowest possible setting.
5) Tighten all fluid connections before
each use. NEVER exceed
3000 psi with
this" unit. Make sure that all accessory
hoses, connections, swivels and so forth
can withstand the high pressures which
develop. NEVER exceed the pressure
rating
of
any component in the system.
6)
WARNING: The paint
hose
can
develop leaks from wear, kinking, abuse,
etc. A leak is capable of injecting fluid into
the skin, therefore the paint hose should
be
inspected before each use. NEVER
attempt to plug a hose with
any
part
of
your
body, adhesive tape
or
any
other
makeshift device. Do not attempt to
repair a spray hose.
Instead, replace it
with a new grounded hose. Use only with
hoses that have spring guards. NEVER
use less than
50' of hose with this unit.
7) Be sure
that
the airless equipment
being used and the object being sprayed
are properly grounded to prevent static
discharge or sparks which could cause
fire
or
explosion. WARNING:
ALWAYS
hold the gun against metal container
when flushing system
with tip removed, to
prevent static discharge. CAUTION:
To
reduce the risk
of
electrical shock, do
not
expose to rain. Store indoors.
GROUNDING INSTRUCTIONS: This
product should be grounded.
In the event
of
an electrical short circuit, grounding
reduces the risk
of
electric shock by
providing an escape wire for the electric
current. This product is equipped with a
cord having a grounding wire with an
appropriate grounding plug.The plug
must
be
plugged into an outlet that is properly
installed and grounded in accordance
with all local codes and ordinances.
GROUNDED
OUTLET BOX
GROUNDED
OUTLET
DANGER - Improper installation of the
grounding plug can result in a risk of
electric shock.
If repair
or
replacement
of
the
cord or plug is necessary,
do
not
connect the grounding wire to either flat
blade terminal.
The
wire with insulation
having an outer surface that is green
(with
or
without yellow stripes) is the
grounding wire. Check with a qualified
electrician
or
serviceman if the grounding
5
instructions
are
not completely
understood,
or
if in doubt as to whether
the product is properly grounded. Do not
modify the plug provided; if it
will not fit
the outlet,
have
the proper outlet installed
by
a qualified electrician.
• This product is for use on a nominal
120-volt circuit and has a grounding
plug that looks like the plug illustrated
below.
• Make sure that the product is
connected
to
an outlet having the same
configuration as the plug. No adapter
should be used with this product.
EXTENSION CORDS: Use only a 3-
wire extension cord that has a 3-slot
receptacle
that
will accept the plug on the
pump. Make sure your extension cord is
in good condition. When using an
extension cord, be sure to use one heavy
enough to carry the current this pump
will
draw.
For
lengths
less
than
25ft.
50 ft.
100ft.
150ft.
Use
extension
gauge
16AWG
14AWG
12AWG
10AWG
An
undersized cord will cause a drop in
line voltage resulting in loss of power and
overheating.
If in doubt, use the next
heavier gauge.
The
smaller the gauge
number, the heavier the cord.
8)
ALWAYS
keep the working area
around the
pump
well ventilated.
Additionally, the pump itself should be a
minimum
of
25' (7.5m) from the spray
area.
If these instructions are not
followed, there is the possibility of fire
or
explosion with certain materials.
ALWAYS
follow the coating
or
solvent
manufacturer's safety precautions and
warnings.
Never
spray flammable
material
near
open flames, pilot lights
or
any source
of
ignition.
9)
ALWAYS
wear
spray masks and
protective eyewear while spraying.
Additional personal protective equipment
may
be required depending on the type
of
material being sprayed and conditions of
ventilation. Always contact supplier of
material being sprayed for
recommendation.
1
0) Keep all extension poles clear of
electrical wires.
11) NEVER alter
or
modify any part
of
this equipment; doing
so
could cause it to
malfunction.
12) NEVER leave equipment
unattended. Keep away from children
or
anyone not familiar with the operation
of
airless equipment.