Airconditioner A010
Instruction Manual
English / Nederlands / Deutsch / Français
www.moacolors.com
Local air conditioners
Caution, risk of fire
Portable Airconditioner - English manual 2
EN
BEFORE USE
Before use, please read this manual carefully.
Only connect the appliance to an earthed wall socket.
This appliance is for household use only. When using electrical
appliances, basic safety precautions should always be followed to
avoid res, electric shocks, burns, or other injuries and damage. Read
these operating and safety instructions carefully.
Our powerful portable air conditioners are great cooling solutions
for single rooms, creating a comfortable atmosphere in your space.
It also has ventilation and dehumidifying function for circulating air
and removal of moisture. They’re self-contained systems that do not
require any permanent installation allowing you to move to the space in
which it is most needed. They’re commonly used in kitchen, temporary-
resided, computer rooms, garages, and many other places where
installation of Air-conditioner Outdoor Unit is limited.
The environmentally friendly R290 is used as the refrigerant. R290
has no damaging inuence on the ozone layer (ODP), a negligible
greenhouse effect (GWP) and is available worldwide. Because of its
efcient energy properties, R290 is highly suitable as a coolant for this
application. Special precautions must be taken into consideration due
to the coolant’s high ammability.
This unit uses a ammable refrigerant.
If refrigerant leaks and comes in contact with re
or heating part, it will create harmful gas and
there is risk of re.
Read the USER MANUAL carefully
before operation.
Further information is available in the
USER MANUAL, SERVICE MANUAL.
Service personnel are required to carefully read
the USER MANUAL and SERVICE MANUAL
before operation.
Portable Airconditioner - English manual 3
EN
APP
The “Smart Life” app is available for android and iOS.
Scan the corresponding QR code to get directly to the download.
Information on How to Use the App
This appliance allows you to operate the appliance via your home net-
work. A prerequisite is a permanent WIFI connection to your router and
the free app “Smart Life”.
We recommend disconnecting the appliance from the power supply
when you are away from home to prevent unintentional switching on
while you are on the road!
Commissioning via the App
1. Install the “Smart Life” app. Create a user account.
2. Activate the WIFI function in the settings of your appliance.
3. Place the appliance at a distance of about 5 meters to your router.
4. As long as the power is turned on, the WIFI indicator ashes slowly.
After 3 minutes, the status will be canceled if there is no network
conguration, and the indicator light is off. If you need to re-connect
the WIFI, long press the “timer” button for 5 Second to start the network
conguration, the WIFI indicator ashes slowly.
5. When WIFI indicator ashes slowly, select “Add Device”-“Large
Home Appliances”-“Air Conditioner”, and follow the instructions on the
display. Select “AP Mode” on upper right of the app, choose “Conrm
indicator slowly blink” and press“Go to Connect” to connect the WIFI
named “SmartLife-XXXX”.
6. Once the appliance has been successfully connected, the WIFI lamp
lights up. Now you can operate the appliance using the app.
7.Press and hold the Timer button for about 5 seconds, the appliance
disconnect, the WIFI lamp lights off.
Portable Airconditioner - English manual 4
EN
APP TROUBLESHOOTING
Network connection timeout:
1.Check if you select the WIFI named “SmartLife-XXXX”.
2.Turn off the machine and unplug the power code and plug in after 10
seconds, enter the App to connect again.
WIFI indicator off:
Long press the “Timer”button or Turn off the machine and unplug the
power code and plug in after 10 seconds.
WIFI hotspot disappear and the WIFI light ash:
Turn off the machine and unplug the power code and plug in after 10
seconds, enter the App to connect again.
Portable Airconditioner - English manual 5
EN
Portable Airconditioner - English manual 6
EN
Portable Airconditioner - English manual 7
EN
IMPORTANT SAFEGUARDS (1/6)
1. This appliance is intended to be used by expert or trained users
in shops, in light industry and on farms, or for commercial use by lay
persons.
2. This appliance can be used by children aged from 8 years
and above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a
safe way and understand the hazards involved. Children shall not play
with the appliance. Cleaning and user maintenance shall not be made
by children without supervision.
3. The unit is designed only for use with R-290(propane) gas as the
designated refrigerant.
4. The refrigerant loop is sealed. Only a qualied technician should
attempt to service!
5. Do not discharge the refrigerant into the atmosphere.
6. R-290 (propane) is ammable and heavier than air.
7. It collects rst in low areas but can be circulated by the fans.
8. If propane gas is present or even suspected, do not allow untrained
personnel to attempt to nd the cause.
9. The propane gas used in the unit has no odor.
10. The lack of smell does not indicate a lack of escaped gas.
11. If a leak is detected, immediately evacuate all persons from the
store, ventilate the room and contact the local re department to advise
them that a propane leak has occurred.
12. Do not let any persons back into the room until the qualied service
technician has arrived and that technician advises that it is safe to
return to the room.
Portable Airconditioner - English manual 8
EN
IMPORTANT SAFEGUARDS (2/6)
13. No open ames, cigarettes or other possible sources of ignition
should be used inside or in the vicinity of the units.
14. Component parts are designed for propane and non-incentive and
non-sparking. Component parts shall only be replaced with identical
repair parts.
FAILURE TO ABIDE BY THIS WARNING COULD RESULT IN AN
EXPLOSION, DEATH, INJURY AND PROPERTY DAMAGE.
15. If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualied persons in order to
avoid a hazard.
16. The appliance shall be disconnected from its power source during
maintenance.
17. Always operate the unit from a power source of equal voltage,
frequency and rating as indicated on the product identication plate.
18. Always use a power outlet that is grounded.
19. Unplug the power cord when cleaning or when not in use.
20. Do not operate with wet hands. Prevent water from spilling onto the
unit.
21. Do not immerse or expose the unit to rain, moisture or any other
liquid.
22. Do not leave the unit running unattended. Do not tilt or turn over the
unit.
23. Do not unplug while the unit is operating.
24. Do not unplug by pulling on the power cord.
25. Do not use an extension cord or an adapter plug.
26.Do not put objects on the unit.
Portable Airconditioner - English manual 9
EN
IMPORTANT SAFEGUARDS (3/6)
27. Do not climb or sit on the unit.
28. Do not insert ngers or other objects into the air outlet.
29. Do not touch the air inlet or the aluminum ns of the unit.
30. Do not operate the unit if it is dropped, damaged or showing signs
of product malfunction.
31. Do not clean the appliance with any chemicals.
32. Ensure the unit is far away from re, inammable, or explosive
objects.
33. The unit shall be installed in accordance with national wiring
regulations.
34. Do not use means to accelerate the defrosting process or to clean,
other than those recommended by the manufacture.
35. The appliance shall be stored in a room without continuously
operation sources (for example: open ames, an operating gas
appliance or an operating electric heater).
36. The appliance shall be stored so as to prevent mechanical damage
from occurring.
37. Do not piece or burn, even after use.
38. Be aware that refrigerants may not contain an odour.
39. Pipe-work shall be protected from physical damage and shall
not be installed in an unventilated space, if that space is smaller than
12m².
40. Compliance with national gas regulations shall be observed.
41. Keep any required ventilation openings clear of obstruction.
42. The appliance shall be stored in a well-ventilated area where the
room size corresponds to the room area as specied for operation.
Portable Airconditioner - English manual 10
EN
IMPORTANT SAFEGUARDS (4/6)
Warning: Any person who is involved with working on or breaking
into a refrigerant circuit should hold a current valid certicate from
an industry-accredited assessment authority, which authorizes their
competence to handle refrigerants safely in accordance with an
industry, recognized assessment specication.
Warning: Servicing shall only be performed as recommended by
the equipment manufacturer. Maintenance and repair requiring
the assistance of other skilled personnel shall be carried out under
the supervision of the person competent in the use of ammable
refrigerants.
43. Checks to the area:
Prior to beginning work on systems containing ammable refrigerants,
safety checks are necessary to ensure that the risk of ignition is
minimized. For repair to the refrigerating system, the following
precautions shall be complied with prior to conducting work on the
system.
44. Work procedure:
Work shall be undertaken under a controlled procedure so as to
minimize the risk of a ammable gas or vapor being present while the
work is being performed.
45. General work area:
All maintenance staff and others working in the local area shall be
instructed on the nature of work being carried out. Work in conned
spaces shall be avoided. The area around the work space shall be
sectioned off. Ensure that the conditions within the area have been
made safe by control of ammable material.
46. Checking for presence of refrigerant:
The area shall be checked with an appropriate refrigerant detector
prior to and during work, to ensure the technician is aware of
potentially ammable atmospheres. Ensure that the leak detection
equipment being used is suitable for use with ammable refrigerants,
i.e. no sparking, adequately sealed or intrinsically safe.
47. Presence of re extinguisher:
If any hot work is to be conducted on the refrigeration equipment or
any associated parts, appropriate re extinguishing equipment shall
be available to hand. Have a dry powder or CO2 re extinguisher
adjacent to the charging area.
Portable Airconditioner - English manual 11
EN
IMPORTANT SAFEGUARDS (5/6)
48. No ignition sources:
No person carrying out work in relation to a refrigeration system
which involves exposing any pipe work that contains or has contained
ammable refrigerant shall use any sources of ignition in such a manner
that it may lead to the risk of re or explosion. All possible ignition
sources, including cigarette smoking, should be kept sufciently far
away from the site of installation, repairing, removing and disposal,
during which ammable refrigerant can possibly be released to the
surrounding space. Prior to work taking place, the area around the
equipment is to be surveyed to make sure that there are no ammable
hazards or ignition risks. “No Smoking” signs shall be displayed.
49. Ventilated area:
Ensure that the area is in the open or that it is adequately ventilated
before breaking into the system or conducting any hot work. A degree
of ventilation shall continue during the period that the work is carried
out. The ventilation should safely disperse any released refrigerant and
preferably expel it externally into the atmosphere.
50. Checks to the refrigeration equipment:
Where electrical components are being changed, they shall be
t for the purpose and to the correct specication. At all times the
manufacturer’s maintenance and service guidelines shall be followed. If
in doubt consult the manufacturer’s technical department for assistance.
The following checks shall be applied to installations using ammable
refrigerants:
– The charge size is in accordance with the room size within which the
refrigerant containing parts are installed;
– The ventilation machinery and outlets are operating adequately and
are not obstructed;
– If an indirect refrigerating circuit is being used, the secondary circuit
shall be checked for the presence of refrigerant;
– Marking to the equipment continues to be visible and legible.
Markings and signs that are illegible shall be corrected;
– refrigeration pipe or components are installed in a position
where they are unlikely to be exposed to any substance which may
corrode refrigerant containing components, unless the components
are constructed of materials which are inherently resistant to being
corroded or are suitably protected against being so corroded.
Portable Airconditioner - English manual 12
EN
IMPORTANT SAFEGUARDS (6/6)
51. Checks to electrical devices:
Repair and maintenance to electrical components shall include initial
safety checks and component inspection procedures. If a fault exists that
could compromise safety, then no electrical supply shall be connected
to the circuit until it is satisfactorily dealt with. If the fault cannot be
corrected immediately but it is necessary to continue operation, an
adequate temporary solution shall be used. This shall be reported to the
owner of the equipment so all parties are advised.
Initial safety checks shall include:
-those capacitors are discharged: this shall be done in a safe manner to
avoid possibility of sparking;
-that there no live electrical components and wiring are exposed while
charging, recovering or purging the system;
-that there is continuity of earth bonding.
WARNING
Install the unit in rooms which exceed 12 m².
Do not install the unit in a place where inammable gas may leak.
NOTE
The manufacture may provide other suitable example or may provide
additional information about the refrigerant odour.
Portable Airconditioner - English manual 13
EN
PARTS & LOCATION
1. Control panel 2. Air outlet with
adjustable louver
3. Handle 4. Air inlet with air lter
5. Caster 6. Drainage Hole
7. Air Exhaust
Note: The appearance is only for reference. Please see the real product
for detailed information.
1. Exhaust hose 2. Remote
3. Window kit adapter
4. Window kit 5. Drain hose
Portable Airconditioner - English manual 14
EN
PLACEMENT
1. If tipped more than 45°, allow the unit to set upright for at least 24
hours before start up.
2. Place the unit on a rm, level surface in an area with at least 50cm
of free space around it to allow for proper air circulation.
3. Do not operate in close proximity to walls, curtains, or other objects
that may block air inlet and outlet. Keep the air inlet and outlet free of
obstacles.
4. Never install the unit where it could be subject to:
- Heat sources such as radiators, heat registers, stoves or other products
that products that produce heat.
- Direct sunlight
- Mechanical vibration or shock
- Excessive dust
- Lack of ventilation, such as cabinet or bookcase
- Uneven surface
WARNING
Install the unit in rooms which exceed 12 m².
Do not install the unit in a place where inammable gas may leak.
NOTE
The manufacture may provide other suitable example or may provide
additional information about the refrigerant odour.
Portable Airconditioner - English manual 15
EN
ATTACH THE HOSE
The air conditioner requires being vented outside so that the exhaust air
can escape the room which coming from the appliance contains waste
heat and moisture.
Do not replace or extend exhaust hose which will result in decreased
efciency, even worse shut down the unit due to low backpressure.
Step 1: Connect the windows kit adapter to the other end of the
exhaust hose.
Step 2: Extend the adjustable window kit the length of your window.
Connect the exhaust hose to the window kit.
Step 3: Close your window to secure the kit in place. It needs to hold
the windows kit rmly in place, secure the window kit with duct tape if
required. It is recommended that the gap between the adapter and the
sides of the window should be sealed off for maximum efciency.
Portable Airconditioner - English manual 16
EN
Step 4: Install the other end of the air outlet on the air conditioning
back card outlet.
Step 6: Adjusting the length of the exible exhaust hose, and avoid
bends in the hose. Then place AC near an electrical outlet.
Step 7: switch on the unit.
Portable Airconditioner - English manual 17
EN
CONTROL PANEL
FUNCTION KEYS AND INDICATORS
1. POWER: Press to switch the machine on or off.
2. MODE :Press to switch the operation mode between cooling,
dehumidier, fan and heating.
3. SPEED: Press to switch the fan speed between HIGH and LOW
4. FAN SPEED Indicator: Display high fan speed & low fan speed.
5. DOWN: Decreasing the desired temperature or timer setting.
6. MODE Indicator: The Mode Display between Cooling,
Dehumidifying, fan and heating.
7. UP: Increasing the desired temperature(16ºC-32ºC) or timer setting.
8. Digital Display: Displays timer setting and room temperature.
9. TIMER: Sets a time for the unit to automatically start or stop.
10.TIMER/POWER Indicator: Display the Power/Time status.
11. WIFI Indicator: Display the WIFI status.
Portable Airconditioner - English manual 18
EN
REMOTE CONTROL
SETTINGS
1. Start-up and Shutdown:
- Press POWER to turn the unit on.
The unit runs in smart mode as default.
- Press MODE button to select the desired operation mode.
- Press POWER again to turn off the power.
Portable Airconditioner - English manual 19
EN
2. Operation mode:
The unit has ve operation modes: Fan, Auto, Cool, Dehumidier,
Sleep.
A.Cooling your room
Select the cool mode to lower the temperature in your room.
- Press MODE button repeatedly until the LED of COOL operation lights
up.
- Press ADD/MINUS button to adjust the temperature which is displayed
on the screen. The temperature can be set between 16ºC and 32ºC.
- Press SPEED button repeatedly until the desired fan speed indicator
lights up.
To control the direction of the air ow horizontally, please adjust the
inner louver by hand. To control the direction of the air ow vertically,
please press the SWING button on.
Note: The air conditioner stops if the room temperature is lower than
selected temperature.
B. Ventilating your room:
- Press MODE button repeatedly until the LED of FAN operation lights
up. In ventilation mode the room air is circulated, but not cooled.
- Press SPEED button repeatedly to select the fan speed as desired.
C. Drying your room:
- Press MODE button on the control panel or remote control, the LED of
DRY operation lights up. The fan speed is unable to select. User should
connect the hose to the drain outlet at the bottom of the unit.
Note: In this mode, the fan speed switches over to low speed and
cannot be selected.
B. Heating your room(Optional for Heating Function Unit only):
-Press MODE button repeatedly until the HEAT indicator lights up.
-Press Up/Down button to set the temperature higher than the room
temperature. The fan speed can also be set.
Note: The drainage hose should be attached to the unit for continuous
operating.
Portable Airconditioner - English manual 20
EN
E. Sleep mode:
The sleep mode can be activated when in cool mode.
In cool mode :
After 1 hour the preset temperature is increased by 1ºC, after another
hour the preset temperature will again be increased by 1ºC.
In heat mode (Optional for Heating Function Unit only) :
After 1 hour the preset temperature is decreased by 1 ºC, after another
hour the preset temperature will again be decreased by 1 ºC.
Then the temperature is kept constant for 10 hours. And all the
indicators dim to dark. The fan speed may switch over to low speed for
silent operating and cannot be selected.
3. Timer settings (1hour-24hours):
The timer has two ways of operation
To turn off (When power on)
1. Press Timer key to turn on the timer function.
2. Press ADD/MINUS repeatedly to set the delay OFF time.
To turn off (When power off)
1. Press Timer key to turn on the timer function.
2. Press ADD/MINUS repeatedly to set the delay ON time.
Cancel timer
1. Press ADD/MINUES repeatedly until the LED shows ‘00’.
Note: when press POWER will also exit the timer setting.
4. Automatic Defrost:
At low room temperatures, frost may buildup at the evaporator during
operation. The unit will automatically start defrosting and the POWER
LED blinking. The defrost control sequence is as follows:
A.When the unit operates in the cooling operation, drying operation,
the ambient temperature sensor senses the evaporator coil temperature
is below -1°C, after the compressor will stop operating for 10 minutes
or the coil temperature up to 7ºC, the unit restart to cool operating
mode.
B.When the unit operates in the drying operation, once the coil
temperature sensor senses the temperature of the evaporator is below
40ºC and the differential temperature between coil temperature and
room temperature is below 19ºC after the compressor operation
for 20minutes, the unit start defrosting for 5 minutes and the power
indicator blinking.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105

Moa A010 Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues