Install Guide
BH61 Wireless Alarm Hub
Document
Document Details
Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © Verkada Inc. All rights reserved.
V1.2 (20220518)
(V1.0 first published 20210929)
Firmware
Firmware version can be verified on
Verkada Command command.verkada.com.
2
Introduction
What’s in the box
What you’ll need
A working internet connection
802.3af / 802.3at POE Power over
Ethernet (PoE) switch, or a PoE injector*
A smartphone or laptop
A Phillips screwdriver or power drill with a
Phillips driver bit
¼ inch (6.5mm) drill bit for wall anchors
● ⅛ inch (3mm) drill bit for pilot holes
3/16 inch (4.5mm) drill bit for machine
screws
*To reduce potential safety issues, only use the PoE
adapter provided with the product, a replacement PoE
adapter provided by Verkada, or a PoE adapter
purchased as an accessory from Verkada.
Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © Verkada Inc. All rights reserved.
BH61 Wireless Alarm Hub
3
Mount plate
(Attached to hub)
Mounting template
3 M4 x 50mm machine screws,
wing nuts, and washers
4 wall anchors T10 Security Torx screwdriver4 M4 x
25mm PH2
wall screws
Connect
For easy registration and setup, scan the QR
code on the product.
If you prefer to manually register your product,
please proceed to: verkada.com/start
Introduction
Sensor overview
Placement
To ensure a reliable connection with your
sensors, mount the BH61 Wireless Alarm Hub in
a location that minimizes the number of walls
and other obstructions between the hub and
the wireless sensors.
Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © Verkada Inc. All rights reserved.
LED
4
LED Behavior
Solid Orange
Hub is on and booting up.
Flashing Orange
Hub is updating firmware.
Flashing Blue
Hub can receive events but cannot
reach the server.
Solid Blue
Hub is running, connected, and
receiving events.
Installation
Connect
Use the provided T10 Torx security
screwdriver to loosen the screws and
lift the top cover off the hub.
Connect the hub to an 802.3af/at Power
over Ethernet (PoE) port on your network.
Please note: Your BH61 Wireless Alarm Hub includes
an integrated backup battery. The Hub must be
connected for eight hours before the battery is fully
charged.
Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © Verkada Inc. All rights reserved.
5
For easy registration and setup, scan
the QR code on the product.
If you prefer to manually register your
product, please proceed to:
verkada.com/start
Installation
Mounting 1/2
To remove the mount plate, loosen the
mount plate screws and twist the
device counterclockwise. Lift the
device vertically off the base plate
and set aside.
Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © Verkada Inc. All rights reserved.
Use the provided mounting
template to mark wall mount
holes. For a junction box mount,
use the mounting template to
determine the correct hole
pattern.
For a solid material like wood or metal,
drill inch pilot holes. Drive mounting
screws directly into the pilot holes.
6
For drywall, drill ¼ inch holes. Insert
plastic anchors into holes and drive
mounting screws into anchors.
Installation
Mounting 2/2
Place the hub over the mount plate
screws and twist clockwise. Tighten
the mount plate screws with a Phillips
screwdriver.
Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © Verkada Inc. All rights reserved.
Replace the hub cover and
secure it using the provided T10
Torx security screwdriver.
7
Installation
Grounding
In order to attach the ground cable to the
hub, perform the following:
Align a 20AWG or larger grounding cable with
a ring terminal and drive an M4-0.7 x 6mm
screw (not included) through the terminal
and into the threaded grounding point on the
back of the device as shown on the right.
Attach the other terminal of a grounding
cable directly to a circuit breaker, ground rod
or earth ground.
This unit is powered by PoE through a UL Listed ITE.
Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © Verkada Inc. All rights reserved.
8
Ground
Appendix
BH61 Compliance
Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © Verkada Inc. All rights reserved.
9
FCC
Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a residential environment. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
To assure continued compliance, any changes or modifications not expressly approved by the party
responsible for compliance may void the user’s authority to operate his equipment. (Example – use only
shielded interface cables when connecting to computer or peripheral devices)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired
operation.
IMPORTANT NOTE:
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with a minimum distance 20cm between the radiator & your
body. This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
IC
Statement
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two
conditions:
(1) This device may not cause interference;
(2) This device must accept any interference, including interference that may cause undesired operation of
the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de
licence. L’exploitation est autorisée aux deux conditions suivantes :
(1) l’appareil ne doit pas produire de brouillage;
(2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance
with RSS-102 RF exposure, users can obtain Canadian information on RF exposure and compliance.
Le dispositif rencontre l'exemption des limites courantes d'évaluation dans la section 2.5 de RSS 102 et la
conformité à l'exposition de RSS-102 rf, utilisateurs peut obtenir l'information canadienne sur l'exposition et la
conformité de rf.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This
equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator
and your body.
Cet émetteur ne doit pas être Co-placé ou ne fonctionnant en même temps qu'aucune autre antenne ou
émetteur. Cet équipement devrait être installé et actionné avec une distance minimum de 20 centimètres
entre le radiateur et votre corps.
Appendix
BH61 Compliance
Caution 1. Maintenance and repair work must always be carried out by qualified technical personnel.
Disconnect power from the unit when performing a maintenance task.
2. Wiring methods used for the connection of the equipment to earth shall be in accordance with the
National Electrical Code, ANSI/NFPA 70, and the Canadian Electrical Code, Part 1, CSA C22.1.
3. The product must be installed and protected in a location that is not easily accessible and is away
from impacts or heavy vibration.
4. The device is only to be connected to PoE networks without routing to outside plants.
5. If powered by a power adapter, the adapter should be properly grounded.
6. Please contact certified dealers for power adapters.
Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © Verkada Inc. All rights reserved.
10
Appendix
Support
Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401
All specifications are subject to change without notice
Copyright © Verkada Inc. All rights reserved.
Thank you for purchasing this Verkada product. If for any reason
things don’t work right, or you need assistance, please contact us
immediately.
verkada.com/support
Sincerely, The Verkada Team
11
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11

Verkada BH61 Guide d'installation

Taper
Guide d'installation

dans d''autres langues