Klein Tools CL320KIT Manuel utilisateur

Catégorie
Mesure, test
Taper
Manuel utilisateur

Ce manuel convient également à

INSTRUCTION MANUAL
ENGLISH
FRANÇAIS pg. 37
ESPAÑOL pg. 19
400A AC Auto-Ranging
Digital Clamp Meter
True RMS
Measurement
Technology
600V
400A
40M
Ω
NON-CONTACT
VOLTAGE TESTING
AUTO-RANGING
DATA HOLD
RANGE HOLD
TEMPERATURE
AUDIBLE CONTINUITY
5001748
2m
-40° –
1832°F
-40° –
1000°C
CL320
INSTRUCTION MANUAL
400A AC Auto-Ranging
Digital Clamp Meter
True RMS
Measurement
VOLTAGE TESTING
AUTO-RANGING
AUDIBLE CONTINUITY
2
400A AC Auto-Ranging
True RMS
Measurement
VOLTAGE TESTING
AUDIBLE CONTINUITY
2
m
CAT III
600V
2
GENERAL SPECIFICATIONS
Klein Tools CL320 is an automatically ranging true root mean square
(TRMS) digital clamp meter that measures AC current via the clamp,
AC/DC voltage, DC microamps, resistance, continuity, frequency,
capacitance, and tests diodes via test-leads, and temperature via a
thermocouple probe.
Operating Altitude: 6562 ft. (2000m)
Relative Humidity: <95% non-condensing
Operating Temp: 32° to 122°F (0° to 50°C)
Storage Temp: 14° to 122°F (-10° to 50°C)
Accuracy: Values stated at 65° to 83°F (18° to 28°C)
Temp Coefcient: 0.1 x (Quoted Accuracy) per °C above
28°C or below 18°C, corrections are required when ambient
working temp is outside of Accuracy Temp range
Dimensions: 8.46" x 3.54" x 1.50" (215 x 90 x 38 mm)
Weight: 11.04 oz. (313 g) including batteries
Calibration: Accurate for one year
Auto Power-Off (APO): After approx. 10 minutes of inactivity
Standards: IEC EN 61010-1, 61010-2-032, 61010-2-033.
IEC EN 61326-1, 61326-2-2.
Conforms to UL STD.61010-1,
61010-2-032,61010-2-033;
Certified to CSA STD.C22.2 NO. 61010-1,
61010-2-032,61010-2-033.
Pollution degree: 2
Accuracy: ± (% of reading + # of least significant digits)
Drop Protection: 6.6 ft. (2m)
Safety Rating: CATIII 600V, Class 2, Double insulation
Electromagnetic Environment: IEC EN 61326-1. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.
Specifications subject to change.
ENGLISH
3
ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy
AC Voltage
(V AC)
400.0mV 0.1mV ±(1.8% + 5 digits)
4.000V 1mV ±(1.5% + 5 digits)
40.00V 10mV
±(1.2% + 5 digits)
400.0V 100mV
600V 1V ±(1.5% + 5 digits)
DC Voltage
(V DC)
400.0mV 0.1mV ±(1.0% + 8 digits)
4.000V 1mV
±(0.8% + 3 digits)40.00V 10mV
400.0V 100mV
600V 1V ±(1.0% + 3 digits)
Input Impedance: 10MΩ
Frequency Range: 45 to 400Hz
Maximum Input: 600V AC RMS or 600V DC
AC Current
(A AC)
4.000A 1mA ±(2.5% + 30 digits)
40.00A 10mA ±(2.5% + 10 digits)
400.0A 100mA ±(2.0% + 10 digits)
Frequency Range: 50 to 60Hz
DC Microamps
(µA DC)
200 μA 0.1 μA ±(1.0% + 5 digits)
Maximum Input: 600V AC RMS or 600V DC
Resistance
400.0Ω 0.1Ω ±(1.2% + 5 digits)
4.000KΩ
±(1.2% + 3 digits)
40.00kΩ 10Ω
400.0kΩ 100Ω
4.000MΩ 1kΩ
40.00MΩ 10kΩ ±(2.0% + 5 digits)
Maximum Input: 600V AC RMS or 600V DC
4
OTHER MEASUREMENT APPLICATIONS
Maximum Input: 600V DC or 600V AC RMS
Diode Test: Approx. 1mA, open circuit voltage ~3.0V DC
Continuity Check: Audible signal <10Ω, max current 1.5mA
Sampling Frequency: 3 samples per second
Overload: "OL" indicated on display
Polarity: "-" on display indicates negative polarity
Display: 3-3/4 digit, 4000 Count LCD
ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy
Capacitance
40.00nF 0.010nF ±(4% + 25 digits)
400.0nF 0.100nF
±(4% + 8 digits)
4.000μF 0.001μF
40.00μF 0.010μF
400.0μF 0.100μF
4.000mF 0.001mF ±(5% + 9 digits)
Maximum Input: 600V AC RMS or 600V DC
Temperature
°F
-40° to 10°F
1
°F
±(1.2% + 7 digits)
11° to 1832°F
±(1.2% + 6 digits)
Temperature
°C
-40° to -12°C
1
°C
±(1.2% + 4 digits)
-11° to 1000°C
±(1.2% + 3 digits)
Maximum Input: 600V AC RMS or 600V DC
Frequency
10Hz to
60kHz
0.001Hz
to 0.01kHz
±(0.1% + 5 digits)
Duty Cycle
0.1% to 99.9%
(≤100kHz)
0.1%
±1.5%
(Range: 10% – 90%)
Maximum Input: 600V AC RMS or 600V DC
ENGLISH
5
WARNINGS
To ensure safe operation and service of the meter, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
Before each use verify meter operation by measuring a known voltage
or current.
Never use the meter on a circuit with voltages that exceed the category
based rating of this meter.
Do not use the meter during electrical storms or in wet weather.
Do not use the meter or test leads if they appear to be damaged.
Use only with CAT III or CAT IV rated test leads.
Ensure meter leads are fully seated, and keep fingers away from the
metal probe contacts when making measurements.
Use caution when working with voltages above 25V AC RMS or 60V DC.
Such voltages pose a shock hazard.
To avoid false readings that can lead to electrical shock, replace batteries
when a low battery indicator appears.
Do not attempt to measure resistance or continuity on a live circuit.
Always adhere to local and national safety codes. Use personal protective
equipment to prevent shock and arc blast injury where hazardous live
conductors are exposed.
To avoid risk of electric shock, disconnect leads from any voltage source
before removing battery door.
To avoid risk of electric shock, do not operate meter while battery door is removed.
SYMBOLS ON METER
AC (Alternating Current)
AC/DC Current
DC (Direct Current) Resistance (in Ohms)
Double Insulated Class II Audible Continuity
Warning or Caution Ground
Diode Risk of Electrical Shock
Hz
Frequency Capacitance
%
Duty-cycle V Voltage (Volts)
°
F/
°
C
Temperature (Fahrenheit / Celsius) A Amperage (Amps)
COM Common NCV
Non-Contact Voltage Tester
% Duty cycle SEL Select
Backlight Hz Frequency
Capacitance Diode Test
Positive Negative
SYMBOLS ON LCD
AC AC (Alternating Current) DC DC (Direct Current)
Negative Reading Data Hold
Auto Ranging MAX Maximum Value Hold
MIN Minimum Value Hold Auto Power Off
Low Battery Audible Continuity
°
F
Degrees (Fahrenheit)
°
C
Degrees (Celsius)
M
Mega (value x 10
6
)
k
kilo (value x 10
3
)
m
milli (value x 10
-3
)
μ
micro (value x 10
-6
)
n
nano (value x 10
-9
)
V
Volts
A
Amps Ohms
Hz%
Frequency/Duty Cycle Auto Power-Off
NCV
Non-Contact Voltage Tester Diode Test
Hazardous Voltage Indicator
6
ENGLISH
FEATURE DETAILS
NOTE: There are no user-serviceable parts inside meter.
1.
4000 count LCD display
8.
"MAX/MIN" button
2.
Function selector switch
9.
Data Hold button
3.
Clamp
10.
Clamp trigger
4.
"COM" jack
11.
Arrow markings
5.
"VΩµA" jack
12.
"SEL/NCV" button
6.
Backlight button
13.
NCV Light
7.
"RANGE" button
14.
NCV Sensing Antenna
1
6
2
9
3
10
14
5
8
7
4
11
12
13
7
FUNCTION BUTTONS
ON/OFF
To power ON the meter, rotate the Function Selector switch
2
from
the OFF setting to any measurement setting. To power OFF the meter,
rotate the Function Selector switch
2
to the OFF setting. By default,
the meter will automatically power OFF after 10 minutes of inactivity.
If the meter automatically powers-OFF while in a measurement
setting, press any button to power the meter ON, or rotate Function
Selector
2
switch to OFF, then power ON the meter.
To deactivate
the power OFF functionality press and hold the "SELECT" button
12
before powering ON from the OFF setting. When auto power OFF
is deactivated, the Auto Power Off icon will not be visible in the
display.
SEL / NCV BUTTON (FOR NCV TESTING)
Press and hold the SEL/NCV button
12
to enter Non-contact Voltage
Testing (NCV) mode to test for presence of AC voltage. The NCV
icon and "EF" will be present on the display. Approach the conductor
under test leading with the sensing antenna
14
.
In the presence of AC
voltage, the red NCV light
13
will flash, audible signals (beeps) will
sound, and dashes will appear on the display.
As the NCV sensing
antenna
14
approaches the voltage source, more dashes will be
presented on the display and the frequency of the audible sound will
increase. Release the SEL/NCV button to exit NCV testing mode.
NOTE: Only voltages of 40V AC or greater will be detected.
BACKLIGHT
Press Backlight button symbol
6
to turn ON or OFF the backlight.
The backlight does not automatically power OFF.
RANGE
The meter defaults to auto-ranging mode . This mode
automatically determines the most appropriate measurement range
for the testing that is being conducted. To manually force the meter
to measure in a different range, use the "RANGE" button
7
.
1. Press the "RANGE" button
7
to manually select measurement
range ( is deactivated on the LCD). Repeatedly press the
"RANGE" button
7
to cycle through the available ranges, stopping
once the desired range is reached.
2. To return to auto-ranging mode, press and hold the "RANGE"
button
7
for more than two seconds ( is reactivated).
8
MAX/MIN
When the "MAX/MIN" button
8
is pressed, the meter keeps track
of the Maximum and Minimum values and the difference between
the Maximum and Minimum values as the meter continues to take
samples.
1. When measuring, press "MAX/MIN" button
8
to toggle between
the Maximum value (MAX), the Minimum value (MIN), and the
difference between Maximum and Minimum (MAX-MIN) values.
If a new maximum or minimum occurs the display updates with
that new value.
2. Press "MAX/MIN" button
8
for more than two seconds to return
to normal measuring mode.
DATA HOLD
Press HOLD
9
to hold the measurement on the display. Press
HOLD
9
again to release the display to return to live measuring.
FUNCTION BUTTONS
ENGLISH
9
OPERATING INSTRUCTIONS
CONNECTING TEST LEADS
Do not test if leads are improperly seated. Results could cause
intermittent display readings. To ensure proper connection, firmly
press leads into the input jack completely.
TESTING IN CAT III MEASUREMENT LOCATIONS
Ensure the test lead shield is pressed firmly in place. Failure to use
the CATIII / CATIV shield increases arc-flash risk.
TESTING IN CAT II MEASUREMENT LOCATIONS
CAT III / CAT IV shields may be removed for CAT II locations. This
will allow testing on recessed conductors such as standard wall
outlets. Take care not to lose the shields.
5/32"
(4 mm)
.7" (18 mm)
INCORRECT
CORRECT
10
OPERATING INSTRUCTIONS
AC CURRENT (LESS THAN 400A)
AC Current is measured by pressing the clamp trigger
10
to open
the clamp and placing it around a current-carrying wire. When
measuring, care should be taken to ensure that the clamp is
completely closed with trigger
10
fully released, and that the wire
passes perpendicularly through the center of the clamp in line with
the arrow markings
11
.
To measure current:
1. Rotate the Function Selector switch
2
to the 40/400 A setting.
2. Place clamp around wire. The current measurement will be shown
in the display.
NOTE: If the measurement is less than 40A, rotate the Function
Selector switch
2
to the 4A setting for improved resolution. If the
measurement is less than 4A, the meter will auto-range to the 4A
range.
Disconnect test leads when measuring with the clamp.
ENGLISH
WIRE
11
OPERATING INSTRUCTIONS
AC/DC VOLTAGE (LESS THAN 600V)
1. Insert RED test lead into VΩµA jack
5
, and BLACK test lead
into COM jack
4
, and rotate function selector switch
2
to the
V
setting for AC or DC measurements. The meter defaults to
AC measurement. To measure DC, press the "SELECT" button
12
to toggle between AC and DC modes. The AC or DC icon on
the LCD indicates which mode is selected. Note "AC" or "DC" on
the display.
Apply test leads to the circuit to be tested to measure voltage.
The meter will auto-range to display the measurement in the most
appropriate range.
NOTE: If "" appears on the LCD, the test leads are being applied to
the circuit in reverse. Swap the position of the leads to correct this.
NOTE: When in a voltage setting and the test leads are open,
readings of order mV may appear on the display. This is noise and
is normal. By touching the test leads together to close the circuit
the meter will measure zero volts.
Red leadBlack lead
12
ENGLISH
CONTINUITY
1. Insert RED test lead into VΩµA jack
5
, and BLACK test lead
into COM jack
4
, and rotate function selector switch
2
to the
Continuity/Resistance/Capacitance/Diode-Test
setting.
NOTE: The meter defaults to Continuity testing in this mode. Ensure
that the Continuity Testing icon is visible on the display. If not,
press the "SELECT" button
12
repeatedly until the icon is shown.
2. Remove power from circuit.
3. Test for continuity by connecting conductor or circuit with test
leads. If resistance is measured less than 10Ω, an audible signal
will sound and display will show a resistance value indicating
continuity. If circuit is open display will show "OL".
µA DC CURENT (LESS THAN 200 µA)
1. Insert RED test lead into VΩµA jack
5
, and BLACK test lead into
COM jack
4
, and rotate function selector switch
2
to the
µA
setting.
2. Remove power from circuit and open circuit at measurement point.
3. Connect test leads in series with the circuit.
4. Apply power to the circuit to take the measurement.
DO NOT attempt to measure continuity on a live circuit.
OPERATING INSTRUCTIONS
DO NOT attempt to measure more than 200 µA.
Red leadBlack lead
Red leadBlack lead
13
OPERATING INSTRUCTIONS
RESISTANCE MEASUREMENTS
1. Insert RED test lead into VΩµA jack
5
, and BLACK test lead
into COM jack
4
, and rotate function selector switch
2
to the
Continuity/Resistance/Capacitance/Diode-Test
setting.
NOTE: The meter defaults to Continuity testing in this mode. Press
the "SELECT" button
12
once to enter Resistance testing mode. The
Resistance icon
will appear on the display.
2. Remove power from circuit.
3. Measure resistance by connecting test leads to circuit. The
meter will auto-range to display the measurement in the most
appropriate range.
NOTE: When in a Resistance setting and the test leads are open
(not connected across a resistor), or when a failed resistor is under
test, the display will indicate O.L. This is normal.
DO NOT attempt to measure resistance on a live circuit.
Red leadBlack lead
14
ENGLISH
CAPACITANCE
1. Insert RED test lead into VΩµA jack
5
, and BLACK test lead
into COM jack
4
, and rotate function selector switch
2
to the
Continuity/Resistance/Capacitance/Diode-Test
setting.
NOTE: The meter defaults to Continuity testing in this mode. Press
the "SELECT" button
12
twice to enter Capacitance testing mode.
The Capacitance icon
will appear on the display. The meter
should read 0 nF with test leads open.
2. Remove power from circuit.
3. Measure capacitance by connecting test leads across the
capacitor. The meter will auto-range to display the measurement
in the most appropriate range.
OPERATING INSTRUCTIONS
Red leadBlack lead
15
OPERATING INSTRUCTIONS
DIODE TEST
1. Insert RED test lead into VΩµA jack
5
, and BLACK test lead
into COM jack
4
, and rotate function selector switch
2
to the
Continuity/Resistance/Capacitance/Diode-Test
setting.
NOTE: The meter defaults to Continuity testing in this mode. Press
the "SELECT" button
12
three times to enter Diode testing mode.
The Diode icon
will appear on the display.
2. Touch test leads to diode. A reading of 200-800mV on display
indicates forward bias, "OL" indicates reverse bias. An open
device will show "OL" in both polarities. A shorted device will
show approximately 0mV.
FREQUENCY / DUTY-CYCLE
1. Insert RED test lead into VΩµA jack
5
and BLACK test lead
into COM jack
4
, and rotate function selector switch
2
to the
Frequency/Duty-Cycle
setting.
NOTE: The meter defaults to Frequency testing in this mode. To enter
Duty-Cycle testing mode, press the "SELECT" button
12
once. Ensure
that the appropriate icon (either
Hz
or
%
) appears on the display.
2. Measure by connecting test leads across the circuit.
Red leadBlack lead
Red leadBlack lead
16
ENGLISH
OPERATING INSTRUCTIONS
TEMPERATURE
1. Insert K-type thermocouple into the VΩµA
5
and COM
4
jacks
(observe polarity markings on thermocouple and meter), and rotate
function selector switch
2
to the Temperature setting.
NOTE: The meter defaults to Fahrenheit scale in this mode. To enter
Celsius scale, press the "SELECT" button
12
once. Ensure that the
appropriate icon (either
°F
or
°C
) appears on the display.
2. To measure temperature, make contact between the
thermocouple tip and the object being measured. When
thermocouple tip and object are in thermal equilibrium, the
measurement on the display will stabilize.
Remove thermocouple before switching meter to other
measurement functions.
The thermocouple included with the original purchase is
suitable for temperatures below 446°F / 230°C only.
To measure higher temperatures, a K-type thermocouple
with the appropriate measurement range should be used.
K-Type
Thermocouple
17
MAINTENANCE
BATTERY REPLACEMENT
When indicator is displayed on LCD, batteries must be replaced.
1. Loosen captive screw and remove battery cover.
2. Replace 3 x AAA batteries (note proper polarity).
3. Replace battery cover and fasten screw securely.
T
o avoid risk of electric shock, disconnect leads from any voltage
source before removing battery door.
To avoid risk of electric shock, do not operate meter while
battery door is removed.
Replace battery cover and fasten screw securely.
18
ENGLISH
CLEANING
Be sure meter is turned off and wipe with a clean, dry lint-free
cloth.
Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when meter is not in use for a prolonged
period of time. Do not expose to high temperatures or
humidity. After a period of storage in extreme conditions
exceeding the limits mentioned in the General Specifications
section, allow the meter to return to normal operating
conditions before using.
WARRANTY
www.kleintools.com/warranty
DISPOSAL / RECYCLE
Do not place equipment and its accessories in the trash.
Items must be properly disposed of in accordance with local
regulations. Please see www.epa.gov or www.erecycle.org
for additional information.
CUSTOMER SERVICE
KLEINTOOLS, INC.
450Bond Street
Lincolnshire, IL60069
1877775-5346
www.kleintools.com
MANUAL DE INSTRUCCIONES
Multímetro digital
de ganchode rango
automáticode
400A CA
600 V
400 A
40 M
Ω
PRUEBA DE VOLTAJE
SIN CONTACTO
RANGO AUTOMÁTICO
RETENCIÓN DE DATOS
RETENCIÓN DE RANGO
TEMPERATURA
INDICADOR DE
CONTINUIDAD AUDIBLE
5001748
2m
-40° –
1832°F
-40° –
1000°C
CL320
MANUAL DE INSTRUCCIONES
Multímetro digital
de ganchode rango
PRUEBA DE VOLTAJE
RANGO AUTOMÁTICO
RETENCIÓN DE DATOS
RETENCIÓN DE RANGO
CONTINUIDAD AUDIBLE
2
m
Multímetro digital
de ganchode rango
PRUEBA DE VOLTAJE
RANGO AUTOMÁTICO
RETENCIÓN DE DATOS
RETENCIÓN DE RANGO
CONTINUIDAD AUDIBLE
m
Tecnología
de medición
media cuadrática
real
ESPAÑOL
CAT III
600V
20
ESPECIFICACIONES GENERALES
Klein Tools CL320 es un multímetro digital de gancho de rango automático
con media cuadrática real (TRMS) que mide corriente CA con las pinzas,
mide voltaje CA/CD, microamperios CD, resistencia, continuidad, frecuencia
y capacitancia, prueba diodos con cables de prueba y mide temperatura con
una sonda de termopar.
Altitud de funcionamiento: 6562' (2000m)
Humedad relativa: <95%, sin condensación
Temperatura de funcionamiento: 32° a 122°F (0° a 50°C)
Temperatura de almacenamiento: 14° a 122°F (-10° a 50°C)
Precisión: valores establecidos según una temperatura ambiente
de65 a 83°F (18 a 28°C)
Coeciente de temperatura: 0,1 × (precisión indicada) por cada
°C por encima de los 28°C o por debajo de los 18°C, es necesario
realizar correcciones si la temperatura del ambiente de trabajo se
encuentra fuera del rango de precisión de temperatura
Dimensiones: 8,46" × 3,54" × 1,50" (215 × 90 × 38mm)
Peso: 11,04 oz (313 g) incluida la batería
Calibración: precisa durante un año
Función de apagado automático (APO): después de
aproximadamente 10minutos de inactividad
Normas: IECEN61010-1, 61010-2-032, 61010-2-033.
IECEN61326-1, 61326-2-2.
Cumple con las normas UL STD.61010-1,
61010-2-032, 61010-2-033;
Certificado según las normas CSA STD.C22.2 n.º 61010-1,
61010-2-032, 61010-2-033.
Grado de contaminación: 2
Precisión: ± (% de lectura + cantidad de dígitos menos significativos)
Protección ante caídas: 6,6' (2m)
Clasicación de seguridad: CATIII 600V, clase 2, doble aislamiento
Entorno electromagnético: IEC EN 61326-1. Este equipo cumple con
los requisitos para su uso en entornos electromagnéticos básicos
y controlados, como propiedades residenciales, establecimientos
comerciales e instalaciones de industria ligera.
Especificaciones sujetas a cambios.
ESPAÑOL
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

Klein Tools CL320KIT Manuel utilisateur

Catégorie
Mesure, test
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues