ATMOR AT-912-36TP Manuel utilisateur

Taper
Manuel utilisateur
www.atmorusa.com
P.N. 105833
Electric Tankless Water Heaters
Thermo Pro2 Series
Model
AT-912-18TP2, AT-912-24TP2, AT-912-29TP2, AT-912-36TP2
Hot Water on Demand
2
Important Safety Guideline
THIS INSTRUCTION MANUAL SHOULD BE SAVED FOR FUTURE REFERENCE.
Denitions: Safety Alert Symbols and Words
This instruction manual uses the following safety alert symbols and words to alert you to hazardous situations and your
risk of personal injury or property damage.
DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious
injury.
WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious
injury.
CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate
injury.
(Used without word) Indicates a safety related message.
NOTICE: Indicates a practice not related to personal injury which, if not avoided, may result in property
damage.
WARNING: PLEASE READ THIS INSTRUCTION MANUAL THOROUGHLY AND COMPLETELY BEFORE
INSTALLATION & USE. FAILURE TO DO SO COULD CAUSE DAMAGE TO PROPERTY, SERIOUS INJURY OR DEATH,
AND VOID YOUR WARRANTY.
Please contact us directly, should you have any questions regarding your unit. We are available Monday- Friday, 9AM-
5PM EST at:
Phone: 1-844-746-6688
For California residents / Pour les résidents de la Californie / Para residentes en California
WARNING: Cancer and Reproductive Harm -
www.P65Warnings.ca.gov.
AVERTISSEMENT: Cancer et Troubles de l'appareil reproducteur -
www.P65Warnings.ca.gov.
ADVERTENCIA: Cáncer y Daño Reproductivo -
www.P65Warnings.ca.gov.
3
Table of Contents
1. Safety Guidelines ---------------------------------------------------------------------------------------------------------- 04
2. About Your Atmor Electric Tankless Water Heater --------------------------------------------------------------------- 04
3. Selecting an Installation location ----------------------------------------------------------------------------------------- 05
4. Mounting Your Water Heater ----------------------------------------------------------------------------------------- 05-07
5. Plumbing Requirements and Precautions --------------------------------------------------------------------------- 07-08
6. Plumbing Installation ------------------------------------------------------------------------------------------------------ 08
7. Electrical Requirements and Precautions ------------------------------------------------------------------------------- 09
8. Electrical Installation --------------------------------------------------------------------------------------------------- 09-11
9. Flow Rate ------------------------------------------------------------------------------------------------------------------ 12
10. Operation Guide ------------------------------------------------------------------------------------------------------- 12-13
11. Care and Maintenance ---------------------------------------------------------------------------------------------------- 13
12. User Interface/Controls ----------------------------------------------------------------------------------------------- 14-15
13. Troubleshooting -------------------------------------------------------------------------------------------------------- 16-17
14. Reset Unit ------------------------------------------------------------------------------------------------------------------ 18
Before Installing
By installing this product, you acknowledge the terms of the manufacturer’s warranty and authorized dealer’s return
policy. Once the heater is installed, do not return the product to the place of purchase. If you have any questions
regarding the warranty or the product return policies, please contact us by phone or email.
4
1. Safety Guidelines
Please read this manual thoroughly before installing & using the instant water heater. Failure to comply with the safety,
installation or operating instructions will void the product warranty. Manufacturer and distributor of the product will
not be liable for any damage or injury caused by the failure to comply with the installation and operating instructions
specied in this manual or the improper use of the product. Ensure that this product is installed in accordance with the
national, state or local electrical and plumbing codes applicable to your area, and as specied in our instructional guide
to get the best performance from your Instant Water Heater.
This product has more than one power connection source. Do not attempt to install, clean, inspect, disassemble,
service or repair the water heater without shutting o all the power sources to the unit on the main electrical panel
using the circuit breaker.
WARNING: Failure to adhere might result in severe injury or death. The water heater must be installed in
compliance with all national, state, provincial and local electrical and building regulations. We recommend that
you consult a qualied electrician and a qualied plumber if you have questions about anything relating to codes
or regulations for this product.
This product is intended for household and indoor use only. Do not immerse in water.
The breaker used to power this unit must be grounded by means of the electrical panel.
The heater must be directly connected to dedicated circuit breakers on the main electrical panel.
Do not install the heater where it may be subjected to direct sunlight, rain, splashing water, moisture/humidity or
freezing temperatures.
This unit is intended for heating water only. Do not attempt to use the unit for heating any other kind of liquid.
2. About Your Atmor Electric Tankless Water Heater
Congratulations on making the decision to purchase one of the best and nest Instant Water Heaters currently available
in the market today! Your new Instant Water Heater features advanced water ow rate and temperature sensors which
are designed to modulate power to the heating elements to maintain a user-selected output water temperature range
for 18KW/24KW/29KW/36KW: 86°F (30°C) to 122°F (50°C) (subject to the temperature of the incoming water).
WARNING: When selecting the water temperature setting of your Instant
Water Heater’s thermostat, factors such as safety and energy conservation should
be considered. Continuous exposure of the skin to water temperatures above
120°F (49°C) can result in severe burns or death. The maximum temperature
to be set on this Instant Water Heater’s thermostat is 122°F (50°C). Always
take precaution to feel the water before bathing or showering to make sure the
temperatures are not too hot. You are required to read and comply with the Time/
Temperature Relationship Chart on the following page to determine the right water
temperature for your home.
Temperature Exposure time resulting in scalding
120°F (49°C) Around 5 minutes of exposure
122°F (50°C) Around 3 minutes of exposure
You may require a 120°F (49°C) or lower thermostat setting to prevent
contact with “HOT” water, if you have small children, disabled, or elderly persons
in your home. The temperature of the water is regulated by the electronic control on the front of the water heater.
Children, disabled and
elderly are at high risk of
being scalded.
See instruction manual
before setting your desired
hot water temperature
Always feel water before
bathing or showering
5
3. Selecting an Installation Location
This Water Heater is designed for indoor installation only.
It should not be installed in a location where it might be subjected to freezing temperatures as the freezing of
the water in the Water Heater can lead to severe and irreversible damages which are not covered under your
warranty.
The Water Heater should not be placed in a location that is dicult to access.
Ensure that the water heater, as well as the power supplies and water connections, are out of reach of
children as the outlet water pipe can get very hot and touching can lead to injury.
Avoid installing your tankless water heater in a location prone to excessive humidity, moisture, or dust, or in an
area where it may be splashed with water or other liquids. DO NOT install underwater pipes or air conditioning
lines that might leak or condense moisture that could then drip onto the heater. DO NOT install above electrical
boxes or junctions.
Do not install in areas which can be damaged due to leakage from the Water Heater. However, safety measure
such as suitable drip pan or an active water leak detector and shuto valve should be installed in such areas
that cannot be avoided.
Item # Unit dimensions (inches) Weight (lbs) Connections
AT-912-18TP2 15.55 x 4.49 x 14.25 9.50 1/2”
AT-912-24TP2 18.90 x 4.49 x 14.25 15.13 3/4”
AT-912-29TP2 18.90 x 4.49 x 14.25 15.13 3/4”
AT-912-36TP2 23.23 x 4.99 x 14.25 18.19 3/4”
WARNING: Water heaters are heat producing appliances. In order to avoid damage, injury or death, there shall
be no materials stored against the water heater and proper care shall be taken to prevent unnecessary contact
(especially by children) with the water heater. UNDER NO CIRCUMSTANCES SHALL FLAMMABLE MATERIALS,
SUCH AS GASOLINE OR PAINT THINNER BE USED OR STORED IN THE VICINITY OF THIS WATER HEATER
OR ANY LOCATION FROM WHICH FUMES COULD REACH THE WATER HEATER.
4. Mounting Your Water Heater
1. Your tankless water heater should be secured to a solid mounting surface with four screws, (minimum 1”
(25.4mm) long).
2. Ensure that the unit is level before fastening the screws in place.
3. The unit must be installed in an upright position with the water inlet and outlet at the bottom of the unit. Do not
install inversely with connections facing up or sideways with connections facing right or left.
4. Do not install the unit above electrical boxes or junctions.
5. The water heater must be installed in a manner that prevents contact with ammable liquids and gases. Keep
these ammable materials at least two feet away from the heater and the hot water outlet pipe. The water heater
and the hot water outlet pipe must be secured, and out of children’s reach to prevent tampering with controls or
contact with an extremely hot pipe.
6. If installing the heater on an upper oor or attic, make sure installation complies with the local codes. Install a drip
pan with drainage, or a leak detector and automatic shuto valve, to prevent damage in case of any leakage.
6
a. Remove the appliance cover. (Heater cover) (gure 3)
b. Mount the unit on the wall with 4 screws at the marked points (gure 4)
c. Make sure the unit is leveled horizontally, with water inlets and outlets at the bottom
(g.5)
24kW, 29kW
18W
Fig. 3 Fig. 4
Fig. 5
Do not install upside down
or on its side
Fig. 6
Water Pre-
Filter
Fig. 3 Fig. 4
Fig. 5
Do not install upside down
or on its side
Fig. 6
Water Pre-
Filter
7
Recommended clearances: 12” (304.8mm) above and below the heater 6” (152.4mm) in front of and to the sides of
the heater
CAUTION: Please keep any ammable materials at least 24” (609.6mm) away from the water heater and hot
water outlet pipe.
5. Plumbing Requirements and Precautions
Please follow all plumbing instructions carefully. This product must be installed in accordance with all national,
state, provincial, and local plumbing codes. We recommend consulting with your municipality or a qualied
plumber if you have questions relating to plumbing codes for your area prior to installing.
The plumbing installation must be completed before the electrical installation.
DO NOT solder any pipe with the unit connected to the pipe. The heat from soldering
may cause damage to the ow sensor. Doing so will void the warranty.
The use of a temperature pressure relief valve (T&P) is not required for most
installations because the tankless water heater does not use a storage tank. UL
Standard 499 does not require that a pressure relief valve is used, although it may
be needed to meet installation codes in your area. In such cases, the pressure relief
valve should be installed in accordance with local codes. It is important to ensure
that the unit is operating correctly, and that air is purged from the valve prior to
installing the water heater.
A T&P valve is recommended for added safety when connecting to plumbing rated Metal, Flex or High-
Temperature CPVC piping.
NOTE: A pressure relief valve is required for installations in the Commonwealth of Massachusetts
and State of Kentucky. Please check your local installation codes for any special requirements.
The plumbing installation requires piping that can withstand pressure up to 8 BAR.
Fig. 7
Do not solder any piping
to the unit’s Connection
points
36W
Fig. 3 Fig. 4
Fig. 5
Do not install upside down
or on its side
Fig. 6
Water Pre-
Filter
8
The maximum operating water pressure for this unit is 150PSI / 10BAR. Residential plumbing systems with
unstable pressure or pressure above 5 BAR require the application of a pressure reduction valve set to 4-5 BAR
for optimal performance.
The water supply ow rate must be at least 0.5 Gallons per Minute (GPM) to ensure proper operation.
Flexible water hoses are recommended to be used with your water heater when installing your water heater.
When connecting the inlet water pipe to the unit, use a wrench to hold the unit’s connection, and another wrench
to tighten so that the ow sensor on the unit will not be loosened or damaged. Do not over-tighten the water inlet
and outlet connections to avoid severe internal damage to the water heater.
We recommend the installation of a manual shut-o valve (ball valve) on the inlet and outlet of the water heater
to create a convenient shut-o point if future maintenance or servicing is required. Before connecting the pipes
to the water heater, it is highly essential to ush the lines to eliminate all the plumbing paste or residue in the lines
caused by any welding or soldering.
All the water pipes within 3 feet (1 meter) of the inlet and outlet connections are recommended to be rated for
high-temperature applications with 150°F (66°C) minimum.
Before proceeding to the electrical installation, run water through the unit for several minutes to ush out any air
bubbles from the water line.
6. Plumbing Installation
STEP 1: Thoroughly ush cold supply line of debris.
STEP 2: Connect the HOT WATER line to the water heater OUTLET. The water heater outlet can be seen on the left
side of the heater when facing the unit. Connect the COLD-WATER line to the water heater marked COLD WATER
INLET which is located on the right side when facing the unit.
* Pre-heated water can be connected to the cold water inlet, where this unit will act as a booster.STEP 3: After
tightening both ttings at the water heater, several hot water faucets should be opened to allow the ow of water
through the water heater for at least 2 to 3 minutes. This process purges all the air from the water lines and MUST be
performed before turning on the power at the unit.
FAILURE TO FOLLOW THIS STEP MIGHT CAUSE PERMANENT DAMAGE TO THE HEATING ELEMENTS. (The
power to the heater should be turned o and the air purged out of the lines before turning the power on anytime
maintenance is performed on the water heater or the homes plumbing system, as air might have been introduced into
the plumbing pipes.)
STEP 4: Carefully inspect all connections, units, and the pressure relief device for leaks after the plumbing installation
is completed. If there are no leaks present, you can proceed to the electrical installation.
CAUTION: If you detect a water leak from the water heater at this point, turn o the water supply at the shut o
valve on the unit’s incoming water supply and contact us at 1-844-783-6082.
Plumbing Specications
Minimum water ow to activate the unit 0.5 gpm
Working pressure 0.5–10 BAR (7–150 psi)
Tested pressure (maximum) 20 BAR (290 psi)
Water connections 18kW 1/2” NPT
Water connections 24, 29, 36kW 3/4” NPT
9
7. Electrical Requirements and Precautions
Manufacturer recommends that this product be installed in accordance with all applicable national, state, provincial,
and local electrical codes. Consult a qualied and licensed electrician if you have questions or are unsure about
anything relating to codes for this product. The heater must be connected to a dedicated circuit breaker on the main
electrical panel.
WARNING: As with all electrical appliances, it’s crucial to rst shut o all power to the unit directly at the fuse or
breaker box before attempting to install, repair or disassemble this water heater. Ensure that the breaker is shut o.
SERIOUS BODILY INJURY OR DEATH COULD OCCUR IF YOU IGNORE THIS WARNING.
CAUTION: All wiring (wire gauge), as well as circuit protection (breaker), must comply with the U.S. National
Electrical Code (NEC) in the USA or the Canadian Electrical Code (CEC) in Canada. Failure to do so could lead to
property damage, personal injury, and void your warranty.
Note: The Canadian Electrical Code generally requires that all supply wires and corresponding circuit protection used
for domestic hot water heating and hydronic heating applications be sized to a minimum of 125% of the maximum
current rating of the heater (check heater specication details below).
Before installing this tankless water heater, ensure that sucient electrical power is available in the home to handle
the maximum amperage load of the applicable heater.
IMPORTANT NOTES:
All water heaters heater requires 3 set of wire and ground (see wiring diagram on page 11)
Please see electrical specications by heater input and wiring diagram on the page 11 for additional electrical
information.
8. Electrical Installation
STEP 1: Take the wire pair and connect to the breaker (see wiring diagram). Be sure that the breaker is connected to
one black wire and one red wire. Be sure the power to the unit is shut o using the dedicated circuit breakers in the
main electrical panel.
STEP 2: Run the correct set of power cable wires from the circuit breaker in the main electrical panel to the water
heater by utilizing a suitable wire gauge which meets all applicable electrical codes for the size of the breaker. Then,
connect the power cable to the block terminal within the water heater.
STEP 3: Unit requires a ground conductor for the incoming circuit.
STEP 4:
DOUBLE CHECK the electrical connections and ensure the wire connections are correct, tight and
secure. It’s important to conrm that the right breaker size and wire gauge has been used and that the unit has been
connected to a ground in accordance with applicable codes. Be sure to reattach the front cover of the unit with two
screws.
STEP 5: Ensure that all the air has been purged from the water lines before turning on power to the unit. Refer to
STEP 3 in the plumbing installation section. Restore power to the unit through the dedicated circuit breaker in the main
electrical panel.
It is crucial to follow the wire connection as shown and ensure all connections are made correctly for
proper operation of the unit. The unit will not operate correctly, even though it turns on and otherwise appears
to function, if you mix up one set of wire with another.
10
Electrical Specications by Heater Input
Item # kW Max
Amps
Required Breaker Req. Wire Size
AT-912-18TP2 18 75 2 x 40A Double Pole 2 x 8/2 AWG with Ground
AT-912-24TP2 24 100 3 x 40A Double Pole 3 x 8/2 AWG with Ground
AT-912-29TP2 29 120.8 3 x 50A Double Pole 3 x 8/2 AWG with Ground
Power Rates
Item # 240V 220V 208V
AT-912-18TP2 18,000 Watts 15,125 Watts 13,520 Watts
AT-912-24TP2 24,000 Watts 20,166 Watts 18,026 Watts
AT-912-29TP2 29,000 Watts 24,368 Watts 21,782 Watts
Terminal Block in Unit
40 Amp
Double Pole
40 Amp
Double Pole
Unit Requires 10 AWG ground wire - one for each 240V circuit
L1L1 L2
8/2 AWG
8/2 AWG
L2
240V
240V
L1 L2 L1 L2
Wiring Diagram for 18kW
Wiring Diagram for 24kW, 29kW
40 Amp
Double Pole
40 Amp
Double Pole
40 Amp
Double Pole
Unit Requires 10 AWG ground wire - one for each 240V circuit
L1L1L1 L2
8/2 AWG
8/2 AWG
8/2 AWG
L2L2
240V
240V
240V
L1 L2 L1 L2 L1 L2
Terminal Block in Unit
11
Electrical Specications by Heater Input
Item # kW Max
Amps
Required Breaker Req. Wire Size
AT-912-36TP2 36 150 4 x 40A Double Pole 4 x 8/2 AWG with Ground
Power Rates
Item # 240V 220V 208V
AT-912-36TP2 36,000 Watts 30,250 Watts 27,040 Watts
Your tankless water heater is now installed and ready to use! Follow the General Operating Instructions to complete
the setup.
Terminal Block in Unit
40 Amp
Double Pole
40 Amp
Double Pole
40 Amp
Double Pole
40 Amp
Double Pole
Unit Requires 10 AWG ground wire - one for each 240V circuit
L1L1L1 L2
8/2 AWG
8/2 AWG
8/2 AWG
L2L2
240V
240V
240V
L1 L2 L1 L2 L1 L2
L1 L2
240V
L1 L2
8/2 AWG
Wiring Diagram for 36kW
12
9. Flow Rate
The chart below indicates maximum temperature rise for a given ow rate
TEMPERATURE RISE CHART (GPM)
Item # kW 30°F 40°F 50°F 60°F 70°F
AT-912-18TP2 18 1.75 GPM 2.04 GPM 2.46 GPM 3.06 GPM 4.1 GPM
AT-912-24TP2 24 5.2 GPM 3.95 GPM 3.52 GPM 3.3 GPM 2.4 GPM
AT-912-29TP2 28.8 5.9 GPM 4.5 GPM 3.87 GPM 3.47 GPM 2.8 GPM
AT-912-36TP2 36 6.2 GPM 5.15 GPM 4.4 GPM 3.9 GPM 3.1 GPM
Based on 105°F Output Water Temp / GPM = Gallons Per Minute
10. Operation Guide
Operating your new tankless water heater is similar to using any traditional water heating system. However, it is essential
that you carefully read all setup procedures, operating instructions and tips to ensure the maximum performance and
energy savings from your new water heater. We recommend that all members of the household read these General
Operating Instructions.
This electric water heater is designed to supply hot water. The unit contains heating elements within, capable of heating
water quickly on-demand for as long as you need it. Unlike a conventional tank storage water heater, this unit is a
tankless water heater that does not store hot water. However, once you begin using the system, you will understand it
works like a conventional tank system.
Tankless system delivers hot water instantaneously on demand. Since a tankless system does not waste energy
continually when heating water, i.e. idly sitting and losing heat in a storage tank, it provides signicant energy savings
than a conventional water heater.
With your new system, as soon as you turn on the hot water faucet, the demand for hot water is detected by a
ow sensor, and the high-power heating elements are activated. Sensors continually monitor the water ow rate and
measured the incoming and outgoing water temperature. Data is transmitted to the system logic controls, which
determines the exact amount of power required by heating elements to heat the water to your desired temperature.
It is essential to keep in mind that all tankless water heaters are subject to a maximum ow rate. If this ow rate is
exceeded, the heater will not be capable of suciently heating water.
Also keep in mind that conventional tank heaters are set to high temperatures to prevent running out of hot water
quickly, and thus a large amount of cold water needs to be mixed in to reach a comfortable level for washing and
showering. Since this unit heats water on demand, it is designed to heat to a lower temperature. This means you only
need to mix in a small amount of cold water or none at all.
Your hot water supply may also be aected by the incoming water temperatures as the season diers. During winter,
if the incoming water temperature is frigid, you might not be able to run multiple hot water outlets at the same time as
compared to the summer. However, you can run showers back-to-back without having to wait for the water to heat.
Water Quality: One of the things which should be taken into consideration when installing and maintaining the water
heater is the quality of water. Water conditions outside the recommended levels outlined below are not permitted and
can damage the water heater. We reserve the right to deny any warranty claim regarding damage suered due to use
in water conditions that are not in accordance with the table below. The water must be treated, and the heater ushed
regularly when this product is installed in an area that is known to have hard water that causes scale build-up to prevent
damage to the heat exchanger and heating elements. We recommend that a water treatment device or water softener
should be installed to maintain optimal performance of the water heater in hard water areas.
13
Chart for Recommended Water Quality levels
pH Total
Dissolved
Solid (TDS)
Free
CO2
Total
Hardness
Aluminum Chloride Copper Iron Manganese Zinc
6.5
-
8.5
Up to
500
mg/L
Up to
500
mg/L
Up to 200
mg/L
Up to
0.2
mg/L
Up to 250
mg/L
Up to 1.0
mg/L
Up to
0.3
mg/L
Up to
0.05
mg/L
Up
to 5
mg/L
11. Care and Maintenance
To ensure maximum performance of your water heater and to reduce the risk of a water leak, we recommend the
following maintenance:
The water heater has minimally required maintenance procedures. Periodic inspections and tests are always
recommended for signs of damage or failure. Any damage, cracks, leakage or weakness should be addressed
and xed immediately. Do not over tighten any of the connections. Over tightening the connection points could
cause severe internal damage to the unit.
Remember that water heated at higher temperatures produces scale buildup much faster than at lower
temperatures. Having manual shut-o/maintenance valves installed on the inlet and outlet of the water heater
will allow access to ush the unit with a descaling solution. We recommend routine maintenance once a year or
once every six months if the water supply has an unusually high level of mineralization (hard water)
Clean the pre-lter on the inlet water side once every six months. Wash lightly to remove any debris.
When any form of maintenance is carried out on the water heater or the home’s plumbing system that may introduce
air into the plumbing pipes, it is crucial to power o the water heater and purge the air out of the lines before allowing
the unit to power up.
FAILURE TO DO SO COULD RESULT IN PERMANENT DAMAGE TO THE HEATING ELEMENT AND VOID YOUR
WARRANTY.
When air is introduced into the plumbing system, follow the steps below to ensure the unit can safely resume operation.
1. Shut o all power connections to the unit at the circuit breaker on the main electrical panel.
2. Perform the maintenance or servicing tasks.
3. Open one or more hot water faucets and allow water to run through the unit for several minutes to purge any air
from the heater and water lines.
This step must be performed before turning on power to the heater. Failure to complete this step may
cause permanent damage to the heating elements.
4. Reconnect power to the unit at the circuit breaker on the main electrical panel. Press and switch the ON position.
5. With the water running through the unit, check and reset the temperature if necessary. The recommended
temperature setting is 118°F (48°C).
14
12. User Interface/Controls
Power
Turn the knob to the right (clockwise) to activate the heater. The display will
light up.
Turn the knob all the way to the left (counterclockwise) to turn o the heater.
Setting the Output Water Temperature
To set the temperature, turn on a hot water faucet and allow water to run
through the heater. Turn the knob clockwise to activate the heater and
display the outlet temperature.
To raise the temperature setting, turn the knob clockwise. To lower the
temperature, turn the know counterclockwise.
The temperature can be set to a level from 90°F to 122°F (30°C to 50°C).
A comfortable temperature for bathing and showering is between 98°F and 105°F (37°C to 41°C).
The recommended temperature setting is 118°F (48°C), which will deliver hot water for all household needs at
a maximum water ow rate.
CAUTION: A higher temperature setting is not recommended, as it can cause severe scalding injuries to
children and elderly persons. Higher temperatures also produce more scale buildup in water heating devices.
115
º
F
Lower
temperature
Raise
temperature
15
Starting the system for the rst time
1. With the water running through the unit, turn the temperature knob clockwise to activate the heater.
2. Turn the knob to adjust the temperature.The recommended temperature setting is 118°F (48°C).
Freezing Temperatures
If the ambient temperature falls below 32°F (0°C), protect the heater from potential damage. Power o the unit using
the dedicated circuit breaker on the main electrical panel. Open a faucet slightly to cause water to ow continuously
through the device at a very low rate, without heating. Restore power to the unit when temperature condition is normal.
If the water inside the heater freezes, it can cause damage that is not covered by warranty. If you suspect water
has frozen within the unit, do not turn it on until you are sure the frozen water has melted, and there are no leaks in the
unit. It is recommended to contact a qualied electrician or the manufacturer for service in this situation.
Digital temperature display
Power & Temperature setting knob
Hot water outlet
(to be connected to the main hot water pipe)
Cold water inlet
16
13. Troubleshooting
Before calling for service, check the troubleshooting list of common issues.
If you are unable to resolve a problem, contact your locally authorized distributor.
PROBLEM
ISSUE
POSSIBLE CAUSE SOLUTION
No hot water
and display do
NOT light up
Power outage or faulty
wiring.
Check the power supply. Check the circuit breakers.
Make sure the breakers at main electrical panel are ON. You may
have a faulty breaker or unit may be wired incorrectly.
Make sure the shuto valve on the unit’s incoming water supply line
is fully open.
The ow rate needed
to activate the heating
element (0.5 gpm) has not
been reached.
Increase the ow rate from the water supply source.
Clean the lter screen on the unit’s water inlet.
No hot water
and display
DOES light up
Reset the unit Refer to manual (Page 18) for diagram of reset points.
Make sure to shut all power on your breaker panel before
attempting to reset unit. All resets must be pressed.
Potential internal part
failure
Please call us for further technical assistance.
Water is
heated, but not
hot enough.
The water ow rate
exceeds the heating
capacity of the heater.
Reduce the water ow rate at the faucet or slightly close the shuto
valve on the unit’s incoming water supply line to reduce the water
ow rate.
Voltage less than 240 Volts The heating elements on your water heater are designed for 240
volts. When used with a lower voltage, they produce less heating
power. You may need to upgrade to a larger input heater.
Crossed Wires. If it’s a new installation, double check the wiring to conrm that it is
correct.
Temperature setting is too
low.
Increase the temperature setting on the unit.
Water pressure is less than
0.5 BAR (7 psi).
Make sure the shuto valve is fully open, and the water supply line is
not blocked.
Mixing too much cold
water
You do not need to mix as much cold water with your tankless water
heater compared to when you use a conventional water heater. You
may also have an anti- scald feature on your faucet that is mixing
cold water. These types of faucets can usually be adjusted to reduce
the amount of cold water mixed.
Thermal loss due to long
pipe run.
As the hot water from the heater runs through the hot water delivery
system to your faucet, some heat will be lost especially if it has long
distance to travel or the pipes are cold. This is normal. You can
compensate for this by increasing the setting on your water heater if
you need/ want hotter water.
Water is
heated, but not
hot enough.
Voltage less than 240 Volts The computer chips in your tankless water heater are programmed
with the expectation that your incoming line voltage is 240 volts. If
you have less than 240 volts [i.e. 208V or 220V], it may aect the
reading on your water heater’s digital display and cause it to read
slightly higher than the actual output temperature. To compensate
for this, increase the setting on your water heater if you need or want
hotter water.
17
Water is too
hot.
The water ow rate
through the heater is too
slow.
Increase the ow rate at the water outlet.
Temperature setting is too
high
Switch to a lower temperature setting.
Water Temperature at
faucet is too hot.
Check for too little ow, or if the set point temperature is too high.
This could possibly indicate a possible internal part failure. Call us for
technical assistance.
Heater shuts
o during use.
Power outage or faulty
wiring.
Check the power supply. Check the circuit breakers.
If the problem persists, please call us for further technical assistance.
Water stops
owing.
Possible Blockage in water
pipes or hoses.
Make sure the main water line valve is fully open, and there are no
obstructions in the water supply line.
Water
temperature
varies from hot
to cold during
use.
Water pressure has
dropped below a minimum
level.
Increase the ow rate from the water supply source.
18
14. Reset Unit
As with all electrical appliances, it is crucial to rst shut o all power to the unit directly at the fuse or breaker box before
attempting to reset this water heater.
WARNING: SERIOUS BODILY INJURY OR DEATH COULD OCCUR IF YOU IGNORE THIS WARNING.
Locate the four reset button locations as shown below and press all buttons. If you hear a “click,” the unit has reset. If
you nd that the unit needs to be reset quite often, please call our customer service for further assistance. Proceed to
turn on your breakers and power on the unit.
18kW
24kW, 29kW
36kW
19
LIMITED WARRANTY
For service, repair or any questions regarding your water heater, call the appropriate 800 number listed within this
section. Please DO NOT return the product to the place of purchase. Also, DO NOT mail the product back to the
manufacturer, nor bring it to a service center without proper instructions and permission from one of our representatives.
The terms of this warranty are solely subject to the original owner and are at no time transferable. A transfer of
ownership will result in immediate termination of this warranty. This warranty is valid only if the product is purchased
from an authorized reseller that has an established direct relationship with the manufacturer.
The manufacturer warrants to the original owner that our instant water heaters will be free from defect in workmanship
and material for TWO YEARS from the date of purchase, and free from leakage for SEVEN YEARS from the date of
purchase. Should any part(s) prove to be defective during this period, the manufacturer will only be responsible for a
replacement water heater or replacement of the defective part(s). The manufacturer is not responsible for labor charges
or any incidental or consequential expenses. If a replacement water heater or part is not available, the manufacturer’s
liability is limited to the cost of the water heater or $1,000.00, whichever is less. The manufacturer is not an insurer, and
the original owner should purchase insurance to cover damage to property or belongings. The original owner agrees
to waive their right to jury trial or to participate in a class action. Also, the original owner agrees to waive subordination
to the extent a loss is covered by insurance, so that their insurance company cannot proceed with action against the
manufacturer for recovery of any claims. Furthermore, all requests must be arbitrated in the state of New Jersey.
Should the owner wish to return the water heater for repair, the owner must rst secure written authorization from
the manufacturer. The owner shall be required to show proof of purchase date and to pay all transportation costs
to return the defective part(s) or water heater for repair or replacement. Warranty is void if: (i) water heater has been
installed or used improperly; (ii) design has been altered in any way; (iii) water heater has been installed and/or serviced
by someone other than a licensed electrician; (iv) or if the water heater has been installed or used in contradiction to
installation instructions, applicable laws and/or ordinances.
Distributed by:
PARAGON GROUP USA LLC
Englewood, NJ 07631
USA
Phone: 1-888-783-6082
Web: www.atmorusa.com
Notes:
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

ATMOR AT-912-36TP Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues