Skov DA 4200 thermometer kit Technical User Guide

Taper
Technical User Guide
DA 4200 thermometer Kit
ø63
Technical User Guide
604529 • 2023-07-05
English For other language variants of this document we refer to:
Español Para otras variantes del idioma de este documento, visite:
Français Pour les versions dans d'autres langues de ce document veuillez consulter:
http://docs.skov.com/1069
DA 4200 thermometer Kit ø63
Technical User Guide 3
Product and Documentation Changes
SKOV A/S reserves the right to change this document and the product herein described without further notice.
In case of doubt, please contact SKOV A/S.
The date of change appears from the front and back pages.
Note
All rights belong to SKOV A/S. No part of this manual may be reproduced in any manner whatsoever without
the expressed written permission of SKOV A/S in each case.
All reasonable efforts have been made to ensure the accuracy of the information contained in this manual.
Should any mistakes or imprecise information occur in spite of this, SKOV A/S would appreciate being noti-
fied thereof.
Irrespective of the above, SKOV A/S shall not accept any liability with regard to loss or damage caused or
alleged to be caused by reliance on any information contained herein.
Copyright by SKOV A/S.
DA 4200 thermometer Kit ø63
Technical User Guide
1 Product description ....................................................................................................................................... 5
2 Product survey ............................................................................................................................................... 6
3 Mounting guide............................................................................................................................................... 7
3.1 Recommended tools.................................................................................................................. 7
3.2 Monting of thermometer............................................................................................................ 8
4 Installation guide.......................................................................................................................................... 11
4.1 Electrical connection............................................................................................................... 11
4.2 General information about circuit diagrams ......................................................................... 11
4.2.1 Power supply isolator................................................................................................................. 11
4.2.2 Letter code ................................................................................................................................. 11
4.3 Cable plans and circuit diagrams........................................................................................... 12
4.3.1 Cable plan.................................................................................................................................. 12
4.3.2 Circuit diagram........................................................................................................................... 12
5 Maintenance instructions ............................................................................................................................ 13
5.1 Recycling/Disposal .................................................................................................................. 13
6 Technical data .............................................................................................................................................. 14
6.1 Flow diagram............................................................................................................................ 14
DA 4200 thermometer Kit ø63
Technical User Guide 5
1 Product description
The DA 4200 thermometer kit ø63 mm is used for reading the flow and return temperature in heating units that
are not controlled by a BlueControl controller.
DA 4200 thermometer Kit ø63
6 Technical User Guide
2 Product survey
439312 DA 4200 thermometer kit ø63 mm
The DA 4200 thermometer kit ø63 mm is used for reading the flow and re-
turn temperature in heating units that are not controlled by a BlueControl
controller.
DA 4200 thermometer Kit ø63
Technical User Guide 7
3 Mounting guide
Check that the ordered parts are present and undamaged before starting assembly. Please read through the
entire guide before starting assembly and fitting.
3.1 Recommended tools
Below is a list of tools recommended for assembly.
Topic Description
Water pump pliers
Adjustable spanner
Utility knife
DA 4200 thermometer Kit ø63
8 Technical User Guide
3.2 Monting of thermometer
Flush supply pipes before connecting them.
Before start-up, fill up the system with water.
Close the 4 ball valves.
Dismount the 2 sensor pockets and DOL 12.
Tighten in opposite direction on the couplings.
DA 4200 thermometer Kit ø63
Technical User Guide 9
Mount the 2 thermometer sensor pockets with packing
twine and joint paste.
Mount the 2 thermometers in the 2 sensor pockets.
Tighten the 2 screws.
DA 4200 thermometer Kit ø63
10 Technical User Guide
Open the 4 ball valves.
Check that there are no leaks.
Check that the thermometers show flow and return
flow temperature.
DA 4200 thermometer Kit ø63
Technical User Guide 11
4 Installation guide
4.1 Electrical connection
Installation, servicing and troubleshooting of all electrical equipment must be carried out by quali-
fied personnel in compliance with the applicable national and international standard EN 60204-1
and any other EU standards that are applicable in Europe.
The installation of a power supply isolator is required for each motor and power supply to facilitate
voltage-free work on the electrical equipment. The power supply isolator is not included.
4.2 General information about circuit diagrams
Symbols are in accordance with the IEC/EN 60617 standard.
The classification of the symbols ("letter codes") on the symbols is in accordance with the IEC/EN 81346-2 stan-
dard.
Reference designations are in accordance with IEC/EN 81346-1:2001 structuring principles and reference des-
ignations. This standard indicates structured methods for naming electrotechnical systems.
4.2.1 Power supply isolator
Power supply isolator
The installation of a power supply isolator is required for each motor and
motor control.
4.2.2 Letter code
The letter codes used in accordance with standard IEC/EN61346-2.
-F -K -M -Q -S -T -W
Protective equipment RCCB /
Initial fuse Protective motor
switch
Controller
Contactor
Fan
Motor
Power supply
isolator
Switch Motor con-
troller
Cable
DA 4200 thermometer Kit ø63
12 Technical User Guide
4.3 Cable plans and circuit diagrams
4.3.1 Cable plan
Power supply isolator
Connection box
Heating unit
Controller
4.3.2 Circuit diagram
0-10 V actuator Circulation pump
Example of terminal number
For correct connection
see the setup menu
Show connection in the controller
Connection box
+24V
0V
Possibly external supply
DA 4200 thermometer Kit ø63
Technical User Guide 13
5 Maintenance instructions
Clean the product with a cloth that has been wrung out almost dry in water and avoid using:
high-pressure cleaner
• solvents
corrosive/caustic agents
5.1 Recycling/Disposal
Products suitable for recycling are marked with a pictogram.
It must be possible for customers to deliver the products to local collection sites/recycling stations in accordance
with local instructions. The recycling station will then arrange for further transport to a certified plant for reuse,
recovery and recycling.
DA 4200 thermometer Kit ø63
14 Technical User Guide
6 Technical data
Thermometer
Mechanical
Diameter mm ø63
Thread " 1/2
Environment
Operating temperature °C 0 to 120
Protection class IP 44
Connection 1/2" x 40 mm
Shipment
Dimension HxWxD mm ø63
Dimensions when packed
HxWxD
mm 85x220x130
Weight g 348
Shipping weight g 450
6.1 Flow diagram
Distribution system/heat source
Return flow Supply flow
Return flow Supply flow
House
(A) 3-way control valve
(B) Actuator 0-10 V
(C) Circulation pump
(D) Non-retur valve
(E) Ball valve
(F) Thermometer
604529 • 2023-07-05 • en-US • Made in Denmark
SKOV A/S • Hedelund 4 • Glyngøre • DK-7870 Roslev
Tel. +45 72 17 55 55 • www.skov.com • E-mail: [email protected]
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Skov DA 4200 thermometer kit Technical User Guide

Taper
Technical User Guide

dans d''autres langues