Invacare Aquatec XL Manuel utilisateur

Taper
Manuel utilisateur

Ce manuel convient également à

Aquatec®R/F/XL
ENBathlift
UserManual................................3
FRElévateurdebain
Manueld'utilisation..........................23
ESAparatoelevadordebañera
Manualdelusuario...........................43
ThismanualMUSTbegiventotheuseroftheproduct.
BEFOREusingthisproduct,readthismanualandsaveforfuturereference.
©2013Invacare®Corporation
Allrightsreserved.Republication,duplicationormodificationinwholeorinpartisprohibitedwithout
priorwrittenpermissionfromInvacare.Trademarksareidentifiedby™and®.Alltrademarksare
ownedbyorlicensedtoInvacareCorporationoritssubsidiariesunlessotherwisenoted.
Contents
ThismanualMUSTbegiventotheuseroftheproduct.
BEFOREusingthisproduct,readthismanualandsaveforfuture
reference.
1General......................................4
1.1Informationabouttheusermanual..............4
1.2Symbols..................................4
1.3Warranty................................4
1.4Intendeduse..............................4
1.5Servicelife................................5
2Safety........................................6
2.1Safetyinformation..........................6
2.2Safetyinformationonelectromagnetic
compatibility..............................6
3Components..................................7
3.1Components..............................7
3.2Identificationlabel..........................8
4Setup........................................9
4.1Safetyinformation..........................9
4.2Settingupthebathlift.......................9
4.3Removingthebathlift.......................11
4.4Chargingthebattery........................12
5Usage........................................13
5.1Safetyinformation..........................13
5.2Controllingthebathlift......................13
5.3Bathing..................................14
6Transport....................................16
6.1Safetyinformation..........................16
7Maintenance..................................17
7.1Maintenanceandservicing....................17
7.2Cleaninganddisinfection.....................17
8AfterUse.....................................19
8.1Storage..................................19
8.2Re-use...................................19
8.3Disposal.................................19
9Troubleshooting...............................20
9.1Identifyingandrepairingfaults..................20
10Technicaldata.................................21
10.1Dimensionsandweight.......................21
10.2Electronicdata.............................21
10.3Materials.................................22
Aquatec
®
R/F/XL
1General
1.1Informationabouttheusermanual
Thisusermanualcontainsinformationandnotesontheproperand
safeuseofthebathlift.
Pleasereadthisusermanualcarefullybeforeusingtheproduct.
Pleaseobserveallthenotes,particularlythesafetyinformation,and
actaccordingly.
Thepositionspecifications(A,B,C,etc.)inthehandlinginstructions
alwaysrefertotheprecedingfigure.
1.2Symbols
Symbolsinthismanual
InthisUserManualwarningsareindicatedbysymbols.Thewarning
symbolsareaccompaniedbyaheadingthatindicatestheseverity
ofthedanger.
WARNING
Indicatesahazardoussituationthatcouldresultin
seriousinjuryordeathifitisnotavoided.
CAUTION
Indicatesahazardoussituationthatcouldresultin
minororslightinjuryifitisnotavoided.
IMPORTANT
Indicatesahazardoussituationthatcouldresultin
damagetopropertyifitisnotavoided.
Givesusefultips,recommendationsandinformation
forefficient,trouble-freeuse.
ThisproductcomplieswithDirective93/42/EEC
concerningmedicaldevices.Thelaunchdateofthis
productisstatedintheCEdeclarationofconformity.
1.3Warranty
Weprovideamanufacturer’swarrantyfortheproductinaccordance
withourGeneralTermsandConditionsofBusiness.Warranty
claimscanonlybemadethroughtherelevantdealer.
Coversandsuctioncupsareexcludedfromthis.
Qualityandelectromagneticcompatibility
Qualityisoftheutmostimportanceforourcompany;allprocesses
arebasedontheISO9001andISO13485standards.
Theproductmeetstherequirementsofthestandards,
DINEN10535(lifts),DINEN60601-1(electricalsafety)and
DINEN60601-1-2(electromagneticcompatibility).
Ithasaliftcapacitygreaterthan1.5timesthenominalload.
Shouldyourequirefurtherinformation,pleasecontacttherelevant
Invacare®subsidiaryinyourcountry(contactaddressesareprovided
onthebackofthisusermanual).
1.4Intendeduse
Thebathliftisintendedexclusivelyasanaidforbathingpeoplewithin
abathtub.Donotuseforanyotherpurpose.
4
1471194-A
General
WARNING!
Riskofinjury
Neverstandonthebathlifttogetintooroutofthe
bathtub,donotuseitforclimbingordescending,asa
liftingplatformorforanysimilarpurpose.
Operatingtemperature:10-40°C
1.5Servicelife
Theexpectedservicelifeisfiveyears,presumingthattheproductis
useddailyandinaccordancewithsafetyinstructions,maintenance
instructionsandintendeduse,statedinthismanual.
1471194-A5
Aquatec
®
R/F/XL
2Safety
2.1Safetyinformation
WARNING!
Riskofinjury
Donotuseafaultyproduct.
Intheeventofamalfunction,contactadealer
immediately.
Donotmakeanyunauthorizedchangesoralterations
totheproduct.
OnlyuseaccessoriesintendedfortheAquatec®bath
lift.
CAUTION!
Dangerofpinchingfingers
Donotinsertfingersintotheguidebetweentheseat
plateandthebackrest.
2.2Safetyinformationonelectromagnetic
compatibility
Thisproductwassuccessfullytestedtointernationalstandardsfor
itselectromagneticcompatibility.However,electromagneticfields
suchasthosegeneratedbyradioandtelevisiontransmitters,radio
equipmentandmobiletelephones,caninfluencetheoperationof
productswithelectricaldrives.Theelectronicsusedinthisproduct
canalsocauseweakelectromagneticinterferencebutthisliesbelow
thestatutorylimits.Youshouldthereforeobservethefollowing
instructions:
CAUTION!
Electromagneticinterference
Electromagneticinterferencecouldcausethebathliftto
stopsuddenlyor(thoughthisisextremelyunlikely)to
startmovingofitsownaccord.
Switchofftheexternaldeviceand/oryourbathliftif
younoticesuchbehavior.
Ifotherelectricallyoperatedmedicalproductscausea
interferenceorarethemselvesdisrupted,switchoff
thebathliftandcontactyourretailer.
61471194-A
Components
3Components
3.1Components
Thefollowingcomponentsareincludedwithinthescopeofdelivery
oftheAquatec®R/F/XL:
Seat
A
B
C
D
E
F
G
H
I
J
A
Sideflap
B
Seatplate
C
Hingeforbackrest
D
Liftingscissors
E
Spindlefootretainer
F
Rearsuctioncups(twotabswiththread)
G
Baseplate
H
Guidefortheslidingshoe
I
Slidingshoe
J
Frontsuctioncups(onetabwithhead)
Backrest
A
B
C
D
E
A
Jackplug
B
Drive
C
Spindlefoot
D
Lockingpin
E
Plate,backrest
1471194-A7
Aquatec
®
R/F/XL
Handcontrolandcharger
A
B
C
E
D
F
A
Handcontrolwithbattery
B
Mainsplug
C
Charger
D
Handcontrolspiralcable
E
Jacksocketofhandcontrol
F
Jackplugofcharger
3.2Identificationlabel
Theidentificationlabelalsocontainsimportantinformation:
A
B
D
C
E
F
G
J
I
H
A
Conformitymark
B
Dutycycle(max.10%,max.2min/18min)
C
Note(disposal)
D
Typeofprotection
E
Serialdevicenumber
F
Note(observeaccompanyingdocuments)
G
Productiontimeframe
H
Loadcapacity
I
Nominalvoltage/ratedpower
J
TypeBappliedpart
Theidentificationlabelisappliedtothebackofthebackrest.
81471194-A
Setup
4Setup
4.1Safetyinformation
IMPORTANT!
Checkthepartsfortransportdamagebefore
commissioningandcontactthedealerifrequired.
Ensureduringassemblythatthepartsarepositioned
correctlywithrespecttooneanother.
4.2Settingupthebathlift
WARNING!
Riskofslipping
Thebathliftcanslipifthesuctioncupsdonothave
agoodhold.
Cleanthebathtubandthesuctioncupsbeforesetting
upthebathlift.
Donotchangethepositionofthebathliftinthe
bathtubonceitissetup.
WARNING!
Riskofinjuryanddamage!
Onlysetupthebathliftinbathtubsthatcomplywith
thespecificationsofthefollowingtable.
A
B
C
H
E
80 mm
A
Tublength,
bottom
800mm
B
Tubwidth,
bottom(inside)
280-600mm
C
Tubwidth,at
80mmheight
(inside)
430mm
E
Tubwidth
(outside)
580-690mm(withspecialsideflaps)
700-740mm(withstandardsideflaps)
750-1000mm(withspecialsideflaps)
H
Tubheight
(inside)
420mm
(withheightadapter,max.+60mm)
1471194-A9
Aquatec
®
R/F/XL
IMPORTANT!
Ensurethatthesuctioncupsaremounted.
Ensurethatthebatteryinthehandcontrolischarged.
Ensurethatthespindlefootisfullyinserted.
Whenlifting,pleaseremember:theseatweighs7.5kg,
thebackrest4.6kg(withoutthehandcontrol).
Ifthebathtubhasahandrail,usethesideflapdiverters.
Foldthesideflapsoutwardsbeforeraisingthe
backrest.
A
B
C
1.PlacetheseatBonthebottomoftheemptybathtub.Ensure
thatthespindlefootretainerCispointingtowardstheendof
thebathtuboppositethedrainA.
2.Foldthesideflapsoftheseatoutwards.
A
B
D
C
3.PlacethebackrestA(withoutthehandcontrol)ontotheseat
sothatthehooksBofthebackrestfitintothehingesCof
theseatplateD.
101471194-A
Setup
IMPORTANT!
Riskofdamage
Damagetotheproductcausedbythespindlefoot
slippingout.
Ensurethatthespindlefootisfullyretracted,
beforefoldingupthebackrest.
Oncethebackrestisfoldedup,ensurethatthe
spindlefootisinthespindlefootretainer.
4.Holdthebackrestatthecenteroftheheadendandcarefullylift
itintotheendposition.
C
B
D
A
5.PlugthejacksocketwiththeunlockingsleeveConthespiral
cableBofthehandcontrolAtothejackplugDuntilthe
lockingmechanismengagesnoticeably.
4.3Removingthebathlift
1.Letthewateroutofthebathtub.
2.LowerthebathliftusingtheDownbuttonuntilthebackrest
stopsintheloweredendposition,5.2Controllingthebath
lift,page13.
3.Unlockthejacksocketonthespiralcableofthehandcontrolby
pushinguptheunlockingsleeveandpullitoffthejackplug.
IMPORTANT!
Riskofdamage
Whenfoldingthebackrestdown,ensurethat
spiralcableofthehandcontroldoesnotbecome
trapped.
Donotfoldthebackrestdownifthereiswater
inthebathtub.
A
C
B
4.Holdthebackrestattheheadendwithonehandandfoldit
forwardstotheendpositionA.
5.PullthebackrestupofftheseatandoutofthebathtubB.
6.FoldthesideflapsoftheseatinwardsC.
IMPORTANT!
Releasebothrearsuctioncupssimultaneously.
1471194-A
11
Aquatec
®
R/F/XL
B
A
7.ReleasetherearsuctioncupAbypullinguponitstabB.
8.Lifttherearoftheseatfurther.Thisreleasesthefrontsuction
cups.
IMPORTANT!
Iftheheightadaptershavebeeninstalled
(optional),youalsohavetopullthetabsofthe
frontsuctioncupstoreleasethem.
9.Lifttheseatoutofthebathtub.
10.Carefullystoreallcomponentsofthebathlift.
4.4Chargingthebattery
Thebathliftcannotbeusedwhenthebatteryischarging.
WARNING!
Riskofelectricshock
Onlyrechargethebatteryindryroomsandneverin
thebathroom.
IMPORTANT!
Onlyusethechargersupplied(Aquatec®R/F/XL)
tochargethebatteryinthehandcontrol.
Onlyconnectthechargertothemainswhenthehand
controlisconnectedtothecharger.
Makesurethatthevoltagespecificationsshownonthe
chargercorrespondtothoseofthemainssupply.
A
B
C
E
D
F
G
1.InsertthejackplugFofthechargerCintothejacksocketE
onthespiralcableDofthehandcontrolAuntilitengages.
2.InsertthemainsplugBofthechargerintoapowersocket.
TheredindicatorlampGonthehandcontrolextinguishes
whenthebatteryiscompletelycharged.Itisnotpossible
to„overcharge“thebattery.
3.Disconnectthechargerfromthepowersocket.
4.Pullthejackplugofthechargeroutofthejacksocketofthe
handcontrol.
12
1471194-A
Usage
5Usage
5.1Safetyinformation
CAUTION!
Overloadingthebathliftcanleadtodamagetothe
deviceorpreventlifting.
Donotoverloadthebathliftandobservethe
specificationsontheidentificationlabeland10.1
Dimensionsandweight,page21
withregardtoits
loadcapacity.
IMPORTANT!
Alwaysperformavisualinspectionoftheproductfor
externaldamagebeforeeachuse.
Rechargethebatterycompletelybeforeeachuse.
5.2Controllingthebathlift
Thebathliftcanbemovedinthefollowingdirections:
Thebathliftiscontrolledviathehandcontrol.
Withafullychargedbattery,theAquatec®RandFcan
perform5bathingoperationswithaloadof140kg.TheXL
canperform4bathingoperationswithaloadof170kg.
A
B
C
D
E
IMPORTANT!
Riskofdamage
Thehandcontrolmayonlybeusedwhenthebackrest
isproperlyinstalledandintheuprightposition.
IMPORTANT!
IfthebatteryinthehandcontrolCisnotsufficiently
charged,theredindicatorlampElightsupredwhenthe
DownbuttonDispressed.Inthiscase,thelowering
functionofthebathliftisdisabled.Youcanhowever
stillraisethelift.
Rechargethebatteryimmediatelyafterraisingit.
Raisingthebathlift
IMPORTANT!
Ifthebackrestislowered,itwillmoveintotheupright
positionfirst(notonmodelF).
1.PresstheUpbuttonBonthehandcontrolandkeepitpressed.
Thebackrestmovesintotheuprightpositionortheseatmoves
upwards.
2.ReleasetheUpbuttononthehandcontrol.
Thebathliftstopsinthecurrentposition.
1471194-A13
Aquatec
®
R/F/XL
Loweringthebathlift
IMPORTANT!
Iftheseatisalreadylowered,thebackrestlowers
towardstherear(notonmodelF).
1.PresstheDownbuttonDonthehandcontrolandkeepit
pressed.
Theseatmovesdownwardsorthebackrestswivelstotherear.
2.ReleasetheDownbuttononthehandcontrol.
Thebathliftstopsinthecurrentposition.
Emergencyoffswitch
IMPORTANT!
OnlypresstheEmergencyOffbuttonAifthedevice
doesnotstopimmediatelywhentheUporDown
buttonisreleased(e.g.ifabuttonjams).Thebathlift
stopsmovingimmediatelyandtheredlightintegratedin
thehandcontrollightsup.
Iftheredindicatorlightgoesoutaftertheemergencyoffbuttonis
released,thefaulthasbeenrectified(e.g.buttonisreleasedagain).
Thedeviceisreadytouseagain.
Iftheredindicatorlightstaysonaftertheemergencyoffbuttonis
released,thefaulthasnotyetbeenrectified.Thedeviceisnotready
foruseandmustberepaired,e.g.intheeventofdamagetothe
electronics.
1.Contactyourspecialistdealer,ifnecessary.
5.3Bathing
WARNING!
Riskofslipping
Thebathliftcanslipifthesuctioncupsdonothave
agoodhold.
Beforeusingthebathliftensurethatitissecurely
positionedandcannottipover.
Ensurethatthebathliftissetupinthebathtub,4.2
Settingupthebathlift,page9
.
WARNING!
Ifyourconditionmeansthatyoucannottakeabathon
yourown,onlyusethedevicewithsupervision.
CAUTION!
Bathoilsorsaltscanimpairtheperformanceofthe
liftingscissors.
Ifusingsuchbathadditives,donotexceedthe
recommendeddose.
IMPORTANT!
Runtheunloadedliftoncetothetopandthenbackto
thebottom(functiontest).
Beforeusing,checkthetemperatureofthebathwater.
1.PressandholdtheUpbuttonBuntiltheseatislevelwiththe
edgeofthebathtub.
2.Makesurethatthesideflapsarelevelwiththeseatandrest
flatontheedgeofthebathtub.
3.Fillthebathwithwater.
4.Sitonthesideflapnearesttoyouasyouwouldonachair.
5.Slidebackwardsuntilyouaresittinginthemiddleoftheseat.
14
1471194-A
Usage
6.Turnyourselfintothebathingposition,byliftingonelegand
thentheotherovertheedgeofthebathtub.
7.Onceyouaresittingcorrectly,presstheDownbuttonDand
holditdowntolowertheseatintothebathtub.
Oncetheseathasreachedthelowestposition,itispossible
toreclinethebackrestbycontinuingtoholdtheDown
buttonD.Thisproducesamorecomfortablebathing
positionandallowsyoutoimmerseyourselfdeeperinthe
bathwater(notonmodelF).
8.KeeptheDownbuttonpresseduntilthebackresthasreached
thedesiredposition.
Togetoutofthebathtub,followingthesestepsinreverse
order.
9.Toraisethebackrestorthebathlift,presstheUpbuttonBand
keepitpresseduntilithasreachedthedesiredposition.
1471194-A15
Aquatec
®
R/F/XL
6Transport
6.1Safetyinformation
CAUTION!
Thebackrestisnotlockedontheseatwhenitisfolded
togetherandcancomeapart.
Onlytransporttheproductattemperaturesbetween
0°Cand40°C,atmosphericpressureof860-1060
hPaandahumidityof30-75%.
Donotremovethesuctioncupswhentransporting
thebathlift.
Removethehandcontrolfromthebackrestfor
transport.
1.Removethehandcontrol.
2.Disassemblethebathliftintotwosectionsfortransport(seat
andbackrest),4.3Removingthebathlift,page11
.
161471194-A
Maintenance
7Maintenance
7.1Maintenanceandservicing
Ifthefollowingcleaningandsafetynoticesareobserved,theproduct
willbemaintenancefree.
IMPORTANT!
Thehandcontrolmayonlybeopenedbythe
manufacturerofthebathlift.
1.Checktheproductregularlyfordamageandtoensurethatitis
securelyassembled.
2.Intheeventofdamageand/ornecessaryrepairs,contactthe
dealerimmediately.
3.Thebathliftmustbecheckedbyanauthorizeddealerbefore
everyre-useorafter24monthsatthelatest(seeManufacturer‘s
recommendationforrehabproductsoftheSPECTARISindustrial
association).
4.Ifthebathliftisnotusedforaprolongedperiod,chargethe
batterycompletelyandthenraiseandlowerthebathlift3times
withoutload.Repeatthisprocessevery12months.Thishelps
tomaintaintheservicelifeofthebattery.
7.2Cleaninganddisinfection
Theproductcanbecleanedanddisinfectedusingcommercially
availableagents.
1.Disinfecttheproductbywipingdownallgenerallyaccessible
surfaceswithdisinfectant(afterdisassemblingtheproduct,if
possible).
Cleaningtheseatandbackrest
CAUTION!
Dangerofpinchingfingers
Beespeciallycarefulwhencleaningintheareaofthe
liftingscissors,astheymaymoveandcauseinjury.
IMPORTANT!
Riskofdamage
Neveruseahigh-pressurecleanertocleanthe
backrest.
1.Washtheproductusingaclothorabrush.
2.Rinsetheproductwithwarmwater.
3.Drytheproductwithacloth.
4.Lightlygreasetheguidefortheslidingshoe(Fig.Sec.3.1,H)
usingVaseline.
Cleaningthecovers(optional)
1.Unbuttonthecoversfromtheseatandbackrest.
2.Washthecoversinawashingmachineatmax.60°Cusing
amilddetergent.
IMPORTANT!
Riskofdamage
Washingathightemperaturescancauseshrinkage.
Donotdrycoversinthetumbledryer.
1471194-A17
Aquatec
®
R/F/XL
Cleaningthechargerandhandcontrol
WARNING!
Riskofelectricshock
Alwaysdisconnecttheplugfromthepowersocket
beforecleaningthecharger.
Neverinsertobjectsmadeofconductivematerial(e.g.
knittingneedles,metalpins)intothejacksocketof
thehandcontrol.
Neveruseawetordampclothtocleanthecharger.
1.Cleanthechargerwithadrycloth.
2.Wipethehandcontrolwithadampclothanddryitwithadry
cloth.
181471194-A
AfterUse
8AfterUse
8.1Storage
IMPORTANT!
Riskofdamage
Storetheproductinadryareaatatemperatureof
between0°Cand40°C,atmosphericpressureof860
-1060hPaandahumidityof30-75%.
Donotstoretheproductnearheatsources.
Donotexposetheproducttodirectsunlight.
8.2Re-use
Theproductissuitableforre-use.Thenumberofre-usesdependson
thefrequencyofuseandthemannerinwhichtheproductwasused.
Beforere-use,theproductshouldundergohygienicpreparationand
becheckedtoensureitisinproperandsafeworkingorder.Repairif
necessary.
8.3Disposal
Thedisposalandrecyclingofusedproductsandpackagingmustbe
conductedinaccordancewiththeapplicablestatutoryregulations.
WARNING!
Neverthrowthehandcontrolintoafireorstoreit
nearnakedflames.
1471194-A19
Aquatec
®
R/F/XL
9Troubleshooting
9.1Identifyingandrepairingfaults
Thefollowingtableprovidesinformationonmalfunctionsandtheirpossiblecauses.Ifyoucannotcorrectthemalfunctionusingthe
remediesnamed,pleasecontactyourdealerdirectly.
Fault
Possiblecause
Remedy
Jacksocketofthehandcontrol
isnotlockedcorrectly.
Lockthejacksocket,
4.2Settingupthebathlift,page9
.
Nomotornoiseaudible/liftdoesnotmove.
Batteryisflat.
Rechargethebatterycompletely,
4.4Chargingthebattery,page12.
Contactsaredirty.Cleanthecontacts,contactyourdealer,ifnecessary.
Cableiscrushed/damaged.Replacethehandcontrol,contactyourdealer,ifnecessary.
Theliftcanberaisedbutnotlowered.
Low-voltageprotectionis
activated.
Rechargethebatterycompletely,
4.4Chargingthebattery,page12.
Theliftstopswhilebeingraised.
Excessiveload.
Observemaximumload,
10.1Dimensionsandweight,page21.
Thebathliftisnotadheringsecurelytothe
bathtub.
Suctioncupsareoldor
damaged.
Replacethesuctioncups,contactyourdealer,ifnecessary.
Faultyelectronics.Haveyourauthorizeddealercheckthehandcontrol. Batteryisnotchargingandtheredindicator
lightflashesduringcharging
Faultybattery.Replacethehandcontrol.
Faultycharger.Haveyourauthorizeddealercheckthecharger.
Batteryistoohot.Donotchargethehandcontrolnearheatsources,e.g.heating
elements,indirectsunlight.Chargingcontinuesautomatically
oncethetemperaturedropstowithinpermissiblelimits.
201471194-A
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64

Invacare Aquatec XL Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à