Power Fist 8785099 Le manuel du propriétaire

Catégorie
Système de soudage
Taper
Le manuel du propriétaire
V4.0 8785099
Please read and understand all instructions before use. Retain this manual for
future reference.
User Manual
125A Inverter Flux Core
Welder
8785099 125A Inverter Flux Core Welder V4.0
2 For technical questions call 1-800-665-8685
SPECIFICATIONS
Input Voltage 120 AC
Input Current Rating 12.6A
Max. Amperage Draw 23A
Phase Single
Output Current Range 50 to 125A
MIG (FCAW) Welding Output @ 30% duty cycle
90A
MIG Welding Voltage Range 16.5 to 20.3V
No-Load Voltage 42V
Welding Capacity Up to 3/16 in.
Wire Feed Speed 80 to 235 in. per minute.
Welding Wire Diameter (Flux) 0.030 or 0.035 in.
Protection Class
IP21S
Generator Compatible Yes
Cooling Fan
INTRODUCTION
The 125A Inverter Flux Core Welder is ideal for small welding jobs with carbon
steel, stainless steel, cast iron, copper and nickel. Among its many features are
IGBT inverter technology, thermal overload protection and waveform control.
SAFETY
WARNING! Read and understand all instructions before using this tool. The
operator must follow basic precautions to reduce the risk of personal injury
and/or damage to the equipment.
Keep this manual for safety warnings, precautions, operating or inspection and
maintenance instructions.
125A Inverter Flux Core
Welder
V4.0 125A Inverter Flux Core Welder 8785099
Visit www.princessauto.com for more information 3
HAZARD DEFINITIONS
Please familiarize yourself with the hazard notices found in this manual. A notice
is an alert that there is a possibility of property damage, injury or death if certain
instructions are not followed.
DANGER! This notice indicates an immediate and specific hazard that will
result in severe personal injury or death if the proper precautions
are not taken.
WARNING! This notice indicates a specific hazard or unsafe practice that
could result in severe personal injury or death if the proper
precautions are not taken.
CAUTION! This notice indicates a potentially hazardous situation that may result
in minor or moderate injury if proper practices are not taken.
NOTICE! This notice indicates that a specific hazard or unsafe practice will
result in equipment or property damage, but not personal injury.
WORK AREA
1. Operate in a safe work environment. Keep your work area clean, well-lit and free
of distractions.
2. Remove all unnecessary people from the work area when welding. Anyone
remaining in the work area must wear the appropriate welding safety equipment.
3. Store tools properly in a safe and dry location. Keep tools out of the reach
of children.
4. Do not weld on damp surfaces that can transmit the electric current without
taking precautions for the welder and bystanders. The welding wire, welding
head and nozzle are electrically ‘hot’.
5. Do not install or use in the presence of flammable gases, dust or liquids.
6. Welding sparks and ejected molten slag can start a fire. Remove
combustible materials within 39 ft (12 metres) of the welding unit. See Fire
and Explosion Precautions.
7. Have a fire extinguisher readily available (see Fire and Explosion Precautions).
8. Use protective screens or barriers to protect others from flash and glare;
warn others in the area to look away from the arc.
8785099 125A Inverter Flux Core Welder V4.0
4 For technical questions call 1-800-665-8685
9. Keep the welding unit at least one foot from any wall or structure.
10. Check that the work area is free from fires, sparks or hot debris before leaving.
PERSONAL SAFETY
WARNING! Wear personal protective equipment approved by the Canadian
Standards Association (CSA) or American National Standards Institute (ANSI).
HEAD PROTECTION
DANGER! Never look directly at the welding arc without the proper protection.
The light can cause flash burn damage and impair vision. Although treatment is
possible, multiple occurrences can result in permanent eye damage.
1. Protect your eyes from welding light by wearing a welder's helmet fitted
with a filter shade suitable for the type of welding you are doing. The
welding process produces intense white light, infrared and ultraviolet light,
these arc rays can burn both eyes and skin.
a. Consult the Welding Shade Guide in Appendix A for the minimum shade
to protect the eyes based on the amperage and type of welding.
2. An opaque helmet will protect against the ultraviolet or infrared light. A
helmet will also protect against ejected hot material and slag. The helmet
should protect the face, forehead, ears and neck.
3. Wear a fire-resistant head covering like a skullcap or balaclava hood to
protect your head when the faceplate is down or when using a welding
hand-held face shield.
4. Wear ventilated safety goggles beneath the welding helmet or behind the
hand-held face shield. The cooling weld bead may fragment or eject slag
that can damage the eyes, when the helmet or hand-held face shield is not
in place.
a. Eye protection equipment should comply with CSA Z94.3-07 or ANSI
Z87.1 standards based on the type of work performed.
5. Wear fire resistant earplugs when welding overhead to prevent spatter or
slag from falling into ear.
V4.0 125A Inverter Flux Core Welder 8785099
Visit www.princessauto.com for more information 5
PROTECTIVE CLOTHING
1. Wear a leather apron or jacket, leather welding gloves and full foot protection.
Choose clothing fabrics that resist sparks, heat, flames and splashes of molten
material. Artificial fabrics may burn and melt, resulting in a more severe injury.
a. Wear welding capes and sleeves when performing overhead welding.
2. Do not wear clothes or protective gear that are frayed, oily or greasy as they
may ignite from the heat or ejected slag and sparks.
3. Wear thick clothes that do not expose the skin. Ultraviolet or infrared light
can burn skin with sufficient exposure.
4. Do not wear clothing that can hold hot debris or sparks such as pant cuffs,
shirt pockets or boots. Choose clothing that has flaps over pockets or wear
clothing to cover the openings such as pant legs over the boots or an apron
over the shirt.
5. Gloves shall should contain an insulating lining to protect against an electric
shock.
6. Rubber soled footwear or electrically insulated work boots are recommended
while working with a welding unit. The non- skid sole is will also help
maintain footing and balance during work.
a. Select boots with steel toe protection to prevent injury from falling
objects.
RESPIRATORS
1. Respiratory protection is needed when ventilation is not sufficient to
remove welding fumes or when there is risk of oxygen deficiency.
a. Wear a NIOSH approved respirator when working on materials that
produce dust or particulate matter.
2. Work in a confined space only if it is well ventilated or while wearing an air-
supplied respirator. Welding fumes and gases can displace air and lower the
oxygen level causing injury or death. Be sure the breathing air is safe (See
Fumes and Gases).
3. The user can take the additional precaution of informing another person in
the work area of the potential danger, so that person can watch for
indications that the user is suffering from oxygen deprivation.
8785099 125A Inverter Flux Core Welder V4.0
6 For technical questions call 1-800-665-8685
PERSONAL PRECAUTIONS
Control the tool, personal movement and the work environment to avoid
personal injury or damage to the tool.
1. Do not operate any tool when tired or under the influence of drugs, alcohol
or medications.
2. Avoid wearing clothes or jewelry that can become entangled with the
moving parts of a tool. Keep long hair covered or bound.
3. Remove all jewelry or metal items from your person before welding. Metal
items may connect to the welding unit’s electrical circuit, causing an injury
or death.
4. Do not overreach when operating the tool. Proper footing and balance enables
better control in unexpected situations.
5. Support the workpiece or clamp it to a stable platform. Holding the
workpiece by hand or against your body may lead to personal injury.
6. Do not wear any personal grooming products that are flammable, such as
hair preparations, perfume or cologne with an alcohol base.
7. Remove any combustibles, such as butane lighters or matches, from your
person before doing any welding. Hot welding sparks may light the matches
or ignite leaking lighter fuel.
SPECIFIC SAFETY PRECAUTIONS
WARNING! DO NOT let comfort or familiarity with product (gained from
repeated use) replace strict adherence to the tool safety rules. If you use
this tool unsafely or incorrectly, you can suffer serious personal injury.
Welding produces sparks, molten slag, intense white light, plus infrared and
ultraviolet light. A cooling bead can eject chips or fragments of slag. Any of
these can cause direct harm to the eyes and skin of the welder or bystanders.
1. Use the correct tool for the job. This tool was designed for a specific function.
Do not modify or alter this tool or use it for an unintended purpose.
2. Welding requires the use a hand-held face shield or helmets with full face
protection per CSA standard Z94.3.1.
3. Protect against reflected arc rays. The rays can reflect off a shiny surfaces
behind the user, into the helmet and off the filter lens into the eyes. Remove
V4.0 125A Inverter Flux Core Welder 8785099
Visit www.princessauto.com for more information 7
or cover any reflective surface behind the user such as a glossy painted
surface, aluminum, stainless steel or glass.
4. Welding produces sparks and molten slag. A cooling bead can eject chips
or fragments of slag. Any of these can cause direct harm to the eyes or skin
of the user or bystanders.
5. Erect protective screens or barriers to protect bystanders from the flash and
glare; warn others in the area not to watch the arc. Do not strike a welding
arc until all bystanders and you (the user) have welding shields and/or
helmets in place.
6. Immediately replace a cracked or broken helmet or a scratched or damaged
lens filter to avoid damage to the eyes or face from arc flash or ejected
molten material.
7. Do not handle hot metal or welding wire with bare hands. Handling may result in
a burn injury.
8. Do not use the welding unit if personal movement is confined or if there is a
danger of falling.
9. Keep all panels and covers securely in place when operating the welding unit.
10. Insulate the ground clamp when not connected to a workpiece to prevent
contact with any metal object.
11. Do not operate the welding unit if the MIG torch, welding cable or ground cable
are wet. Do not immerse them in water. These components and the welding
unit must be completely dry before attempting to use them.
12. Do not point the torch at any body part of yourself or at anyone else.
13. Do not use a welding unit to thaw frozen pipes.
14. Insulate yourself from the work and the ground using dry insulation.
Make certain that the insulation is large enough to cover your full area of
physical contact.
15. When not welding, make certain that no part of the welding circuit is touching
the workpiece or the ground. Accidental contact can cause overheating and
create a fire hazard.
16. Maintain good ventilation of the louvers on this equipment. Good ventilation
is of critical importance for the normal performance and service life of this
equipment.
8785099 125A Inverter Flux Core Welder V4.0
8 For technical questions call 1-800-665-8685
17. When working above floor level, use a safety belt to protect yourself from a
fall should you get a shock.
FIRE AND EXPLOSION PRECAUTIONS
Welding can produce sparks, hot slag or spatter, molten metal drops and hot
metal parts that can start fires.
1. Clear the floor and walls of an area of all combustible and/or flammable
materials up to 39 ft (12 metres) away from the welding unit. Hot debris
ejected during welding can land at a considerable distance away. Solid
floors of concrete or masonry is the preferred working surface.
a. Cover any combustible material with fire resistant covers or shields, if it
cannot be removed. The covering must be tight and should not leave
openings for sparks or ejected slag to enter.
b. Check both sides of a panel or wall for combustible material. Remove
the combustible material before welding.
2. A combustible floor should be protected with a fire resistant covering.
Alternatives are to spray the floor with water to keep it wet for the duration
of the welding or cover with damp sand. Care must also be taken to avoid
an electric shock when this is done. A combustible floor directly laid onto
concrete does not need to be sprayed with water.
3. Seal cracks and openings to adjacent areas that a spark or slag can enter.
Seal any openings found with a fire-resistant cover. Shut doors and windows
that do not provide ventilation or erect protective screens in front of them
when possible.
4. Avoid welding near hydraulic lines or containers containing flammable
contents.
5. Do not perform any welding work on containers that held flammable or
toxic substance, until they are cleaned by a person trained in removing toxic
and flammable substances and vapours per the American Welding Standard
AWS F4.1.
6. Open a container before performing any welding work on it. The heat
generated by the welding process will cause the air and gases to expand.
The internal pressure may cause a sealed or closed container to rupture,
possibly causing an injury or death.
V4.0 125A Inverter Flux Core Welder 8785099
Visit www.princessauto.com for more information 9
7. Do not weld pipes or metal that are covered in combustible material or in
contact with combustible structure such as a wall. Only weld if the covering
can be safely removed.
a. Follow all safety precautions and legal requirements before welding a
workpiece that contains Asbestos or attempting to remove the Asbestos
covering. This requires expert knowledge and equipment.
b. Molten slag can run down the inside and outside of a pipe and start a
fire. Be aware where the pipe terminates and take precautions.
8. Do not weld a panel that is a sandwich construction of combustible and
metal materials.
9. Have a fire extinguisher available for immediate use. A dry chemical fire
extinguisher for Types A, B and C is suggested.
a. Welding a combustible metal like zinc, magnesium or titanium requires
a Type D fire extinguisher.
b. Do not use liquid based fire extinguishing methods near the electric
welding unit, as it may cause a shock hazard.
10. Ventilation systems should be positioned so sparks or molten slag isnt
carried to an adjacent area.
11. Have a Fire Watcher observing areas outside of the welders view, such as
the opposite side of a wall or behind the welder. A fire may also start on the
other side of a structure that could not be removed. The Fire Watcher will
extinguish a fire or raise the alarm to evacuate if the fire cannot be
contained by the extinguishing equipment.
a. A fire watch extends at least 30 minutes after the welding is complete to
ensure there are no fires caused by smoldering sparks or ejected
material.
FUMES AND GASES
WARNING! Stop welding and move to a location with ventilation if your eyes,
nose or throat become irritated. This indicates the ventilation is not adequate
to remove the fumes. Do not resume welding until the ventilation is improved
and the discomfort ceases. Seek medical attention if the symptoms do not
diminish or if the welder experiences nausea, dizziness or malaise.
8785099 125A Inverter Flux Core Welder V4.0
10 For technical questions call 1-800-665-8685
Welding may produce hazardous fumes and gas during the welding process. A well
ventilated work area can normally remove the fumes and gases, but sometimes the
welding produces fumes and gases that are hazardous to your health.
1. Only work in a confined space if the area is well ventilated or while wearing
a respirator or an air-supplied respirator. Welding fumes and gases can
displace air and lower the oxygen level causing injury or death. Be sure the
breathing air is safe. Always have a trained watchperson nearby.
a. If ventilation in the work area is poor, use an approved air-supplied
respirator. All the people in the work area must also have air-supplied
respirators.
b. Oxygen displacement can occur in confined areas when the shielding
gas fills the area and pushes out air. Argon, Propane and Carbon
Dioxide are heavier than air and will fill a confined space from the
bottom up.
2. Avoid positions that allow welding fumes to reach your face. Always attempt to
weld upwindof the workpiece with the airflow across the face of the welder.
Airflow from behind may create a low pressure area in front of the welder and
draw the fumes to the person.
3. Ventilate the work area to remove welding fumes and gases. The fumes and
gases should be drawn away from the user.
a. Ventilation should be enough to disperse fumes, but not enough to
disturb the shielding gas or flame during welding.
b. Ventilation exhaust shall be directed to a non-work area to avoid
exposing other people to potential toxic or dangerous fumes.
c. Air removed from the work area by the ventilation system must be
replenished with fresh air to avoid oxygen starvation or a build-up of fumes
or gases. Only use air to provide ventilation. Any other combination of gases
may be explosive or toxic to people in the work area.
d. Ventilation methods that remove gas and fumes from the welding point
before they reach the welders face should be given preference.
4. Avoid welding in a work area that has vapours from cleaning, degreasing or any
spraying operations. The heat and light from welding can react with the vapour
and form irritating or potentially toxic gases. Wait for the vapours to disperse.
V4.0 125A Inverter Flux Core Welder 8785099
Visit www.princessauto.com for more information 11
5. Consult the manufacturer's Safety Data Sheets (SDS) for instructions and
precautions about metals, consumables, coatings, cleaners and degreasers.
a. Do not weld on coated metals such as galvanized, lead or cadmium
plated steel, unless the coating is removed from the weld area. The
coatings and any metals containing these elements can give off toxic
fumes during the welding process.
b. Do not weld, cut or heat lead, zinc, cadmium, mercury, beryllium or similar
metals without seeking professional advice and inspection of the welding
areas ventilation. These metals produce extreme toxic fumes, which can
cause discomfort, illness and death.
c. Do not weld or cut near chlorinated solvents or in areas that chlorinates
solvents can enter. The heat or ultraviolet light of the arc can separate
chlorinated hydrocarbons into a toxic gas (phosgene) that can poison
or suffocate the user or bystanders.
6. Check the Safety Data Sheet for the proper handling and safety precautions
for consumable welding rods as the coating can have multiple chemicals.
POWER TOOL PRECAUTIONS
This equipment requires a dedicated 120 volt, 20 amp single-phase alternating
current circuit equipped with a similarly rated circuit breaker or slow blow fuse.
Do not run other appliances, lights, tools or equipment on the circuit while
operating this welding unit.
1. Do not drape or carry coiled welding cables on your body while the cables
are plugged into the welding unit.
2. Do not start the tool when the welding wire is touching the workpiece.
3. Hold the tool by the insulated gripping surfaces when performing an operation
where it may contact hidden wiring or its own cord and cables. Contact with a
live’ wire will electrify exposed metal parts and shock the operator.
4. Take work breaks to prevent the tool's motor from overheating and/or
overloading. Refer to the welding unit’s duty cycle in Specifications.
5. Keep hands away from the welding arc and the area it is being applied to
when the tool is in operation.
6. Do not connect the welding unit ground clamp to an electrical conduit. Do
not weld on an electrical conduit.
8785099 125A Inverter Flux Core Welder V4.0
12 For technical questions call 1-800-665-8685
7. Do not touch the welding wire or welded surface immediately after use. The
surface will be hot and may cause an injury.
ELECTRICAL SAFETY
1. Do not come into physical contact with the welding current circuit. The
welding current circuit includes:
a. The workpiece or any conductive material in contact with it.
b. The ground clamp.
c. The welding wire;
d. Any metal parts on the wire feed torch.
e. The output terminals.
2. The welding wire reel, welding head, nozzle and semiautomatic welding guns
are electrically hotwhen the welding unit is in semiautomatic or automatic
wire welding mode.
3. Insulate yourself from the electrical current and ground using electrical
insulating mats or covers big enough to prevent physical contact with the
workpiece or ground.
4. Connect the ground clamp as close to the welding area on the workpiece as
practical to prevent welding current from traveling along an unexpected
path and causing an electric shock or fire hazard.
a. An option is to attach the ground clamp to a bare metal spot on a metal
workbench. The circuit will complete as long as the workpiece is also in
full contact with the bare metal workbench.
5. Only use insulated connectors to join welding cables.
6. Ensure there are no contacts between the workpiece and work area that
would allow it to ground, other than through the ground cable circuit
7. Do not exceed the duty cycle or amperage required for the type of welding.
Excessive amperage can cause the deterioration of protective insulation and
create a shock hazard.
8. Unplug the welding unit when not in use as the unit as current is still
entering the unit, even when it is turned off.
9. Frequently inspect input power cable for wear and tear, replace the cable
immediately if damaged. Bare wiring is dangerous and can kill.
V4.0 125A Inverter Flux Core Welder 8785099
Visit www.princessauto.com for more information 13
10. Do not use damaged, under sized or badly joined cables.
11. Do not disconnect the power cord in place of using the ON/OFF switch on
the tool. This will prevent an accidental startup when the power cord is
plugged into the power supply.
a. In the event of a power failure, turn off the machine as soon as the
power is interrupted. The possibility of accidental injury could occur, if
the power returns and the unit is not switched off.
12. Make certain the power source conforms to requirements of your equipment
(see Specifications).
POWER CORD
1. Insert the power cord plug directly to the power supply whenever possible.
Extension cords are not recommended for use with this welding unit.
a. When an extension cord is required, use a welding version that exceeds
the welding unit’s maximum power requirement.
2. Do not operate this tool if the power cord is frayed or damaged, as an electric
shock or surge may occur, resulting in personal injury or property damage.
a. Inspect the tool's power cord for cracks, fraying or other faults in the
insulation or plug before each use.
b. Discontinue use if a power cord feels more than comfortably warm
while operating the tool.
3. Keep all connections dry and off the ground to reduce the risk of electric
shock. Do not touch plug with wet hands.
4. Prevent damage to the power cord by observing the following:
a. Do not pull on the cord to disconnect the plug from an outlet.
b. Keep cord away from heat, oil, sharp edges or moving parts.
c. Place the electrical cord in a position that prevents it from contacting
the tool or workpiece. The cord should always stay behind the tool.
5. Make sure to locate the cord so that it is not stepped on, tripped over or
otherwise subject to damage or stress.
6. Do not wrap the cord around the tool, as sharp edges may cut insulation or
cause cracks if wound too tight. Gently coil cord and either hang on a hook
or fasten with a device to keep cord together during storage.
8785099 125A Inverter Flux Core Welder V4.0
14 For technical questions call 1-800-665-8685
LOW VOLTAGE
Low voltage may cause overheating due to higher power current being drawn to
the tool that will shorten the motor life.
An extension cord may cause a drop in power to the tool if it is too long or the
amperage rating is not correct. This may result in the following:
1. The tool will not activate when switched on.
2. The tool may switch on, but fails to maintain power when applied to
a workpiece.
3. The tool may overheat, possibly starting a fire.
Test the tool by plugging it directly to the power supply. If it powers on, change
the extension cord with to one with the correct rating and as short as needed.
You may need to position the workpiece closer to the power supply.
ELECTROMAGNETIC FIELDS
WARNING! Stop welding immediately and move away from the welding unit if
you feel faint, dizzy, nausea or shocks. Seek medical attention.
Electromagnetic Fields (EMF) can interfere with electronic devices such as
pacemakers. Anyone with a pacemaker should consult with their doctor before
working with or near a welding unit. The following steps can minimize the
effects of electromagnetic fields.
1. Twist or tape cables together and prevent coils.
2. Do not drape cables on your body.
3. Keep the welding power source and cables as far away from the user as
practical. A minimum of 24 in. is recommended.
4. Connect the workpiece clamp as close to the weld as possible, but lay the
MIG torch and workpiece cables away from the user.
5. Use the lowest current setting possible during welding.
6. Avoid long and regular bursts of energy while welding. Apply the welding
wire in short strokes and intermittently. This will prevent the pacemaker
from interpreting the signal as a rapid heartbeat.
7. Keep the lead cable and ground cables on the same side of your body.
8. Do not weld while carrying the welding power source.
9. Do not work next to, sit or lean on the welding power source.
V4.0 125A Inverter Flux Core Welder 8785099
Visit www.princessauto.com for more information 15
UNPACKING
WARNING! Do not operate the tool if any part is missing. Replace the
missing part before operating. Failure to do so could result in a malfunction
and personal injury.
Remove the parts and accessories from the packaging and inspect for damage.
Make sure that all items in the contents are included.
Contents: Welding Machine MIG Torch • Ground Lead with Clamp
Brush/Hammer • Contact Tips
IDENTIFICATION KEY
A. Welding Machine
B. Voltage Selector Dial – Reduce or increase the voltage by turning the
voltage selector dial. Different materials and material thickness will require
different voltage settings. Refer to the Suggested Settings Chart on the
inside door of the welding unit.
C. Power LightIlluminates when the electrical power is active.
Fig. 1
8785099 125A Inverter Flux Core Welder V4.0
16 For technical questions call 1-800-665-8685
D. Alarm LightIlluminates when the welding machine overheats. Power
output will shut-off automatically, but the fan will continue to run until the
heat is dispersed.
E. Amperage/Wire Speed DialIncrease the amperage and wire feed speed
by turning the dial. The number 1 is the slowest wire feed speed, 10 is the
highest. You will need to adjust or ‘tune inyour wire speed for different
welding conditions (thickness of metals, metal type, wire size, etc.). When
the wire speed is properly ‘tuned-in’ the welding wire will melt into the
material you are welding as quickly as it is fed through the welding torch.
IMPORTANT! The wire will feed faster without an arc. When an arc is
being drawn, the wire speed will slow.
F. Ground Clamp – Attaching the ground clamp to your workpiece ‘completes
the welding current circuit. You must attach the ground clamp to the metal
you are welding. A poor connection at the ground clamp will waste power
and heat. Scrape away dirt, rust, scale, oil or paint from the clamping
surface before attaching the ground clamp.
G. Welding Cable and TorchThe welding wire is fed through the welding cable
and welding torch when the welding torch trigger is pulled. You will need to
install a contact tip and welding nozzle to the end of the welding torch.
BACK PANEL
H. Power Switch – This switch turns the welding unit ON and OFF. Make sure
the power switch is in the OFF position before performing any maintenance
on the welding unit.
I. Power CordThis is a standard power cord.
ASSEMBLY & INSTALLATION
Numbered references in parenthesis (#1) refer to the included Parts List. Letter
references in parenthesis (A) refer to the included Identification Key. Dashed
numbers in parenthesis (Fig. 1-1) refer to a specific point in an illustration or image.
V4.0 125A Inverter Flux Core Welder 8785099
Visit www.princessauto.com for more information 17
POWER REQUIREMENTS
NOTICE! Do not operate this welding unit if the actual power source voltage
is less than 105 volts AC or greater than 132 volts AC. Improper performance
and/or damage to the welding unit will result if operated on inadequate or
excessive power.
This welding unit is designed to operate on a properly grounded 120 volt, 60
Hz, single-phase alternating current (AC) power source that has a 20 amp time
delayed fuse or circuit breaker. The use of the proper circuit size can eliminate
nuisance circuit breaker tripping when welding.
A qualified electrician should verify the actual voltage of the power outlet,
confirm the outlet is grounded and that the fuse is properly installed.
SHIELDING GAS
Shielding gas protects the exposed weld. The flux core in the welding wire
becomes a gas that expands to cover the molten metal, preventing impurities in
the air from contacting and weakening the weld.
The most common flux is 75% Argon and 25% Carbon Dioxide. There are other
flux mixes available based on the welding task.
ALIGN AND SET THE DRIVE ROLLER
The correct drive roller grove must be set on the wire drive mechanism before
the welding wire is installed in the unit.
1. Open the door to the welding units drive compartment.
2. Remove the drive tension by loosening the drive tension adjusting knob
(Fig. 2-1) and lifting the drive tension adjustor away from the drive tension
arm (Fig. 2-2). Pull the drive tension arm away from the drive roller.
3. If there is a wire already installed in the welding unit, roll it back onto the
wire spool by hand-turning the spool counterclockwise. Be careful not to
allow the wire to come out of the rear end of the inlet guide tube (Fig. 2-3)
without holding onto it or it will unspool itself. Put the end of the wire into
the hole on the outside edge of the wire spool and bend it over to hold the
wire in place. Remove the spool of wire from the drive compartment of the
welding unit.
8785099 125A Inverter Flux Core Welder V4.0
18 For technical questions call 1-800-665-8685
4. Rotate the drive roller Cap (Fig. 2-4) counterclockwise and remove it from
the drive roller.
5. Pull the drive roller off of the drive roller shaft.
DRIVE ROLLER ADJUSTMENTS
The drive roller has two knurled grooves
built into it for different wire sizes. The
correct wire size number is stamped on
each side of the drive roller. The number
facing you when installing the drive
roller must match the wire size. Use only the proper size drive roller when using
your welding unit. Table 1 indicates which drive roller groove should be used
with each wire diameter size.
1. Find the side of the drive roller (Fig. 3-1) that is
stamped with the same wire diameter (Fig. 3-2)
as that of the wire being installed. Push the
drive roller onto the drive roller motor shaft
(Fig. 3-3), with the side stamped with the
desired wire diameter facing you.
2. Reinstall the drive roller cap (Fig. 2-4) and lock
in place by turning it clockwise.
3. Close the door to the welding unit drive compartment.
Any spool of wire that is oxidized should be discarded. Check if only the
exposed top layer of wire is oxidized by unspooling and checking the next layer.
Wire Diameter Drive Roller Groove
0.030 in. 0.8
0.035 in. 0.9
Table 1
Fig. 2
V4.0 125A Inverter Flux Core Welder 8785099
Visit www.princessauto.com for more information 19
INSTALL THE WELDING WIRE
WARNING! Electric shock can kill! Always turn the power switch OFF and unplug
the power cord from the power source before installing the welding wire.
Remove old wire from the torch assembly before installing new welding wire. This
will help to prevent the possibility of the wire jamming inside the torch liner.
1. Remove the nozzle and contact tip from the end of the torch assembly.
a. Check that the power is OFF and the power cord unplugged before
removing the welding nozzle. The contact tip on this welding unit is
electrically hot whenever the torch trigger is pulled.
2. Make sure the proper groove on the
drive roller is in place for the installed
wire. Change the drive roller if the
proper grove is not in place (see Align
and Set the Drive Roller).
3. Find the leading end of the wire. Do not
unhook it. The leading end goes
through a hole in the outer edge of the
spool and is bent over the spool edge to
prevent the wire from unspooling.
4. Place the spool on the spindle so the wire is straight, not at an angle, when it
enters the welding unit mechanism (Fig. 4). The welding wire should always
come off the top of the spool into the drive mechanism.
5. The purpose of the drive brake is to halt the spool of wire at
nearly the same moment that wire feeding stops.
a. Four Inch Wire Spool - Install the drive brake hardware on
the top of the spool of wire as shown in Fig. 5.
6. Set the spool tension. Too much tension and the wire will slide
on the drive roller or the wire wont feed into the mechanism.
Too little tension and the wire may unspool itself. Readjust the
drive brake tension to correct for either problem.
a. Turn the wire spool with one hand and while adjusting
the tension with the other hand.
b. Tighten (turn clockwise) the drive tension adjustment
knob with your free hand.
8785099 125A Inverter Flux Core Welder V4.0
20 For technical questions call 1-800-665-8685
c. Stop tightening when drag is felt on the wire spool that you are turning.
d. The wire spool is ready for use.
7. Free the leading end of the wire from the spool and use wire cutters to
remove the bent portion, leaving a straight 90° cut. Do not let go of the
welding wire while doing this, as the wire may unspool itself.
8. Loosen the tension adjusting knob holding the drive tension arm in place
and lift the tension arm away from the driver roller.
9. Insert the leading end of the wire into the inlet guide tube. Then push the
wire across the drive roller and insert six inches into the torch assembly.
a. Make certain that the welding wire is actually going into the torch liner
and not alongside it. A misaligned wire may be deflected in another
direction and could damage the internal mechanisms.
10. Line the wire in the drive roller groove, then place the drive tension arm on
the drive roller.
11. Flip the quick release drive tensioner back up into position on the drive
tensioner arm.
12. Tighten (turn clockwise) the drive tension adjusting knob until the tension
roller is applying enough force on the wire to prevent it from slipping out of
the drive assembly.
13. Let go of the wire.
14. Connect the welding unit power cord to the power source.
15. Turn the welding unit ON.
16. Set the voltage switch to the voltage (heat) setting recommended for the
gauge metal that is to be welded. Refer to the label mounted on the cover,
inside the drive compartment, for recommended voltage (heat) settings for
your welding job.
17. Set the wire speed control to the middle of the wire speed range.
18. Straighten the torch cable and pull the trigger on the welding torch to feed
the wire through the torch assembly.
19. When at least an inch of wire sticks out past the end of the torch, release
the trigger.
20. Turn the power switch to the OFF position.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76

Power Fist 8785099 Le manuel du propriétaire

Catégorie
Système de soudage
Taper
Le manuel du propriétaire

dans d''autres langues