Smart Thermostat Premium Thermostat Intelligent Premium
WELCOME!
If you have questions, we have answers.
Visit ecobee.com/support for tutorials,
how-to videos and FAQs. Technical support
is also available by email orby phone:
1-866-518-6740
COMPATIBLE SYSTEMS
Smart Thermostat Premium works with
mostcentralized residential heating and
coolingsystems.
Heating: Up to 2 stages
Cooling: Up to 2 stages
Heat pumps: Air, Water, and Geothermal with
upto 2 stages, and 2 stages of AUX heat.
Accessories: Dehumidier, humidier, or
ventilation device.
Fan coil units: 2- and 4-Pipe with up to 3 fan
speeds. Pipe sensors supported.
Packaged Terminal Air Conditioners (PTAC):
Up to 3 fan speeds
TERMINAL DESCRIPTIONS
G Fan
Rc Cool transformer
Rh Heat transformer
O/B Heat pump reversing valve
Y1, Y2 Used for 1-2 stages of conventional A/C
or 1-2 stages of heat pump compressor
W1, W2 Used for 1-2 stages of conventional
heat or 1-2 stages of auxiliary heat
withheat pump
C 24VAC common
ACC+/– Used for dehumidiers, humidiers,
ventilators, HRVs or ERVs
PEK+ Power Extender Kit (PEK), which extends
a C-wire when a physical wire is not
available. PEK sold separately for Pro
Builder models.
BIENVENUE!
Vous avez des questions, nous avons les réponses.
Visitez ecobee.com/support pour les tutoriels,
les vidéos d’installation et la FAQ. Une assistance
technique est également offerte par courriel ou
par téléphone :
1-866-518-6740
SYSTÈMES COMPATIBLES
Le Thermostat Intelligent Premium fonctionne
avec la plupart des systèmes de chauffage et
declimatisation résidentiels.
Chauffage : jusqu’à deux phases
Climatisation : jusqu’à deux phases
Thermopompes : à air, à eau et géothermique
jusqu’à 2 phases, avec chauffage d’appoint à
2phases.
Accessoires : déshumidicateur, humidicateur
ou dispositif de ventilation.
Serpentins de ventilateur : à 2 ou 4 tuyaux jusqu’à
3 vitesses de ventilation. Capteurs pris en charge.
Climatiseurs terminaux autonomes (PTAC) :
jusqu’à 3 vitesses de ventilation
DESCRIPTION DES BORNES
G Ventilateur
Rc Transformateur de refroidissement
Rh Transformateur de chaleur
O/B Robinet inverseur pour thermopompe
Y1, Y2 Utilisé pour les phases 1 et 2 de système
de climatisation classique ou les phases 1
et 2 du compresseur de la thermopompe
W1, W2 Utilisé pour les phases 1 et 2 de
systèmede chauffage classique ou les
phases 1 et 2 de chauffage d'appoint
avec thermopompe
C Câble commun 24 VAC
ACC+/– Utilisé pour les déshumidicateurs,
humidicateurs, ventilateurs, VRÉ ou VRC.
PEK+ Bloc d’alimentation (PEK), qui prolonge
le câble C si aucun câble physique n’est
offert. PEK est vendu séparément pour
les modèles Pro Builder.
CONVENTIONAL HEATING AND COOLING
(UP TO 2 STAGES EACH)
SYSTÈME DE CHAUFFAGE ET DE CLIMATISATION
CLASSIQUE (JUSQU’À 2 PHASES CHACUN)
CONVENTIONAL HEATING AND COOLING
(WITH PEK)
2-PIPE FAN COIL UNIT WITH AUX HEAT
(PIPE SENSORS OPTIONAL)
BOILER OR RADIANT SYSTEM CHAUDIÈRE ET SYSTÈME DE CHAUFFAGE PAR
RAYONNEMENT
HEAT PUMP (AIR OR GEOTHERMAL)
WITH AUXILIARY HEAT
Rc
Rh
W1
W2
ACC+
ACC–
G
C
Y1
Y2
PEK+
OB
W1 W2 Y1 Y2 G R C
AIR CONDITIONER
Y1 Y2 C
Rc
Rh
W1
W2
ACC+
ACC–
G
C
Y1
Y2
PEK+
OB
W1 W2 Y1 Y2 G R C
Y1 Y2 C
RW Y G
RY W G C
Rc
Rh
W1
W2
ACC+
ACC–
G
C
Y1
Y2
PEK+
OB
FOURNAISE
W1 W2 Y1 Y2 G R C
CLIMATISEUR
Y1 Y2 C
RW Y G
RY W G C
Rc
Rh
W1
W2
ACC+
ACC–
G
C
Y1
Y2
PEK+
OB
AIR HANDLER
W1O/B W2 Y1 Y2 G R C
HEAT PUMP
OB W2 Y1 Y2 R C
Rc
Rh
W1
W2
ACC+
ACC–
G
C
Y1
Y2
PEK+
OB
SYSTÈME DE TRAITEMENT D'AIR
W1O/B W2 Y1 Y2 G R C
OB W2 Y1 Y2 R C
Rc
Rh
W1
W2
ACC+
ACC–
G
C
Y1
Y2
PEK+
OB
PTAC
W Y G1 G2 G3 R C
Rc
Rh
W1
W2
ACC+
ACC–
G
C
Y1
Y2
PEK+
OB
PTAC
W Y G1 G2 G3 R C
NOTES:
1. When using a PEK with a heat pump
system, the O/B terminal is wired directly
to the thermostat.
2. The PEK is not compatible with dual
transformer or fan coil units.
NOTE: Self-powered 24V accessories can be controlled
using theACC+ and ACC− terminals.
NOTE : Les accessoires autonomes 24 V peuvent être
contrôlés au moyen de bornes ACC+ et ACC−.
NOTE: Heat pumps use an internet-based weather feed and
do not require outdoor temp sensor and/or a dual-fuel kit.
NOTE : Les thermopompes utilisent une liaison par Internet
pour les prévisions météo et ne requièrent aucun capteur
de température extérieure et/ou une trousse bicarburant.
NOTE: G1, G2, G3 may also be labeled as GL, GM, GH
NOTE: G1, G2, G3 may also be labeled as GL, GM, GH
NOTE : G1, G2, G3 peuvent également être identiés
comme GL, GM, GH
Stage 2 compressor, if applicable Compresseur à 2 phases (le cas échéant)
THERMOPOMPE (À AIR OU GÉOTHERMIQUE)
AVEC CHAUFFAGE D’APPOINT
4-PIPE FAN COIL UNIT SERPENTIN DE VENTILATEUR
À 4 TUYAUX
1-WIRE ACCESSORY
4-PIPE FAN COIL
R W/Y
HEAT
Y/A
COOL
G1 G2 G3 C
Rc
Rh
W1
W2
ACC+
ACC–
G
C
Y1
Y2
PEK+
OB
SERPENTIN DE VENTILATEUR À 4 TUYAUX
R W/Y
CHAUFFAGE
Y/A
CLIMATISATION
G1 G2 G3 C
Rc
Rh
W1
W2
ACC+
ACC–
G
C
Y1
Y2
PEK+
OB
C R G Y W
Rc
Rh
W1
W2
ACC+
ACC–
1-WIRE to ACCESSORY
G
C
Y1
Y2
PEK+
OB
C R G Y W
Rc
Rh
W1
W2
ACC+
ACC–
1 CÂBLE à ACCESSOIRE
G
C
Y1
Y2
PEK+
OB
ACCESSOIRE 1 CÂBLE
WARNING! ecobee Smart Thermostat Premium is designed for 24VAC with a 2A
maximum current. Do not connect it to line (high) voltage or millivolt systems.
IMPORTANT — TURN OFF POWER
Power off the HVAC system with the master switch or circuit breaker box.
AVERTISSEMENT ! Le Thermostat Intelligent Premium ecobee est conçu pour une
tension de 24 VCA avec un courant maximal de 2 A. Ne le reliez pas à une tension
secteur (haute tension) ou à des systèmes à millivolt.
IMPORTANT - ÉTEINDRE L’ALIMENTATION ÉLECTRIQUE
Éteignez le système CVC à l’interrupteur principal ou la boite du disjoncteur.
Stage 2 heat
and cool, if
applicable
Stage 2 heat and cool, if applicable Phase 2 chauffage et climatisation (le cas échéant)
SYSTÈME DE CHAUFFAGE ET DE CLIMATISATION
CLASSIQUE (AVEC PEK)
NOTES :
1. Lorsqu’un PEK est utilisé avec un
système de thermopompe, la borne O/B
est reliée directement au thermostat.
2. Le PEK n’est pas compatible avec les
transformateurs mixtes ou les serpentins
de ventilateur.
Phase 2
chauffage et
climatisation
(le cas
échéant)
R W/Y
VALVE
Y/A G1 G2 G3 C
Rc
Rh
W1
W2
ACC+
ACC–
S1 S2
G
C
Y1
Y2
PEK+
OB
SERPENTIN DE VENTILATEUR À 2 TUYAUX
R W/Y
VALVE
Y/A G1 G2 G3 C
Rc
Rh
W1
W2
ACC+
ACC–
CAPTEUR
S1 S2
G
C
Y1
Y2
PEK+
OB
SERPENTIN DE VENTILATEUR À 2 TUYAUX AVEC
CHAUFFAGE D’APPOINT (CAPTEURS FACULTATIFS)
Rc
Rh
W1
W2
ACC+
ACC–
G
C
Y1
Y2
PEK+
OB
AIR CONDITIONER
Y1 Y2 C
BOILER
W1 W2 R
AIR HANDLER
Y1 Y2 R C G
Rc
Rh
W1
W2
ACC+
ACC–
G
C
Y1
Y2
PEK+
OB
CLIMATISEUR
Y1 Y2 C
CHAUDIÈRE
W1 W2 R
SYSTÈME DE
TRAITEMENT D'AIR
Y1 Y2 R C G
PACKAGED TERMINAL AIR CONDITIONER
(PTAC) WITH MULTISPEED FAN
NOTE : G1, G2, G3 peuvent également être identiés
comme GL, GM, GH
CLIMATISEUR TERMINAL AUTONOME
(PTAC) AVEC VENTILATEUR
MULTIVITESSES
465-00396
Installation Settings
THRESHOLD SETTINGS Menu > Settings > Installation Settings > Thresholds
SETTING NAME DESCRIPTION DEFAULT
Conventional & Heatpump
Systems
Auto Heat/Cool In Auto mode, the thermostat will engage both your heating and cooling as necessary. Enabled
Heat/Cool Min Delta The minimum temperature difference between the desired Heat and Cool set points in
Auto mode. 5F
Congure Staging
Congure staging Manually, to select and customize values such as dissipation time,
temperature deltas, and runtimes for both your heating and cooling equipment.
(See*Manual Setting Options)
Automatic
Compressor Min Cycle Off Time The amount of time the compressor remains off between cycles. 300 seconds
Compressor Min Outdoor
Temperature The AC or Heatpump compressor will not run below this outdoor temperature.
AC - 35F /
Heatpump -
User dened
AC Overcool Max Will allow the air conditioner to overcool (above Cool set point) by this value to help
decrease humidity. Disabled
Heat Min On Time The minimum amount of time the furnace/boiler will stay on during a call for heat. 5 minutes
Compressor Min On Time The minimum amount of time the compressor will stay on. 5 minutes
Temperature Correction If the thermostat sensor reading is incorrect, a correction may be applied to achieve an
accurate reading. +0F
Humidity Correction If the thermostat sensor reading is incorrect, a correction may be applied to achieve an
accurate reading. +0%
Thermal Protect The minimum temperature reading difference between sensors that will trigger the
algorithm to ignore the inaccurate sensor reading. Disabled
Installer Code When enabled, this restricts access to Installation Settings (Code 3262 permits access) Disabled
Heatpump only Systems
Aux Savings Optimization This setting simplies Heatpump to Aux Heating staging based on Savings vs. Comfort.
The higher the temperature setting will sacrice comfort for savings. 2F
Aux Heat Max Outdoor
Temperature The Auxiliary Heat will not run above this outdoor temperature. 35F
Aux Min On Time The minimum amount of time your auxiliary heat will stay on during a call for aux heat. 5 minutes
Compressor To Aux Temperature
Delta
The minimum number of degrees from the current temperature vs. set point before
engaging the auxiliary heat. Auto
Compressor to Aux Runtime The minimum number of minutes the Heatpump compressor will run for before switching
to auxiliary heat. Auto
Aux Reverse Staging When enabled, aux heat will be engaged if the current temperature is greater than the
value designated in the Compressor to Aux Temperature Delta setting. Off
*Manual Setting Options
Heat Differential Temperature The minimum temperature differential before engaging heating. 0.5F
Heat Dissipation Time The amount of time the fan will continue to run once the heating cycle is completed. Auto
Cool Differential Temperature The minimum temperature differential before engaging cooling. Auto
Cool Dissipation Time The amount of time the fan will continue to run once the cooling cycle is completed. Auto
Compressor Reverse Staging When enabled, second stage compressor will be engaged if the current temperature is
greater than the value designated in the Compressor Stage 2 Temperature Delta setting. Off
Compressor Stage 2 Temperature
Delta
The minimum number of degrees from the current temperature vs. set point before
engaging the second stage of the compressor. Auto
Compressor Stage 1 Max Runtime The maximum number of minutes running stage 1 before engaging the second stage of
the compressor. Auto
Heat Reverse Staging When enabled, second stage heat will be engaged if the current temperature is greater
than the value designated in the Heat Stage 2 Temp Delta setting. Off
Heat Stage 2 Temp Delta The minimum number of degrees from desired setpoint before engaging the
2ndstageof heat. Auto
Heat Stage 1 Max Runtime The maximum number of minutes running stage 1 before engaging the second
stageheating. Auto
ACCESSORY SETTINGS Menu > Settings > Installation Settings > Equipment
SETTING NAME DESCRIPTION DEFAULT
Humidier
Evaporative or Steam An ‘Evaporative’ humidier will operate with a heating cycle where an ‘Steam’ humidier
can operate with/without a heating cycle. User dened
Min Runtime Delta The humidier will run beyond the desired humidity setpoint by the selected amount 5%
Window Efciency The Frost Control setting uses the efciency rating to determine the desired humidity
within the range of 15 to 50%. 2
Dehumidier
Dehumidify with Fan When enabled, this will activate the furnace/air-handler fan during a call for
Dehumidication. Yes
Min Runtime Delta The dehumidier will run beyond the desired humidity setpoint by the selected amount 5%
Dehumidify in Heat Mode Will permit the Dehumidier to operate independent of a heating cycle. No
Dehumidier Active This setting is dependent whether the HVAC system or Dehumidier requires it to be
open or closed while active. User dened
Ventilator
Pre-Occupancy Purge Enable to run ventilator for 1 hour prior to expected occupancy Disabled
Free Cooling Max Outdoor
Temperature Free Cooling will not run when the outdoor temperature is above this point 72F
Free Cooling Max Outdoor
Temperature Maximum Outdoor Humidity to permit Free Cooling to run Disabled
Indoor/Outdoor Temperature Delta Permit Free Cooling if Indoor Temp vs. Outdoor Temp is greater than Temperature Delta 2F
Max Desired Temperature Delta Maximum delta between current and desired temperature to engage Free Cooling Disabled
Pre-Occupancy Purge Enable to run ventilator for 1 hour prior to expected occupancy Disabled
REMINDERS & ALERTS SETTINGS Menu > Reminders and Alerts > Preferences
SETTING NAME DESCRIPTION DEFAULT
HVAC Maintenance Maintenance interval for the heating & cooling systems. Enabled,
6months
Furnace Filter The frequency of lter reminders based on months or runtime hours. Enabled,
3months
UV Lamp The frequency when maintenance is needed based on months or runtime hours. Disabled
Low Temp Alert When indoor temperature meets/exceeds this setting an alert will be generated. Enabled, 50F
High Temp Alert When indoor temperature meets/exceeds this setting an alert will be generated. Enabled, 92F
Aux Outdoor Temp Alert An alert will be generated when Aux Heat is used at this value or above. Disabled
Aux Heat Runtime Alert An alert will be generated when Aux Heat meets/exceeds this runtime value
ina24hrperiod. Disabled
Low Humidity Alert An alert will be generated if humidity falls below this value. Disabled
High Humidity Alert An alert will be generated if humidity rises above this value. Disabled
Display Alerts on Thermostat When enabled, Alerts will also appear on the thermostat display. Disabled
Enable Heating/Cooling Alerts An alert will be generated indicating that the system has failed to heat or cool
theindoorlocation. Enabled
Paramètres d’installation
PARAMÈTRES DES SEUILS Menu > Paramètres > Paramètres d’installation > Seuils
NOM DU PARAMÈTRE DESCRIPTION VALEUR PAR DÉFAUT
Systèmes classiques etthermopompes
Chauffage/climatisation automatique En mode Auto, le thermostat active le chauffage ou la climatisation selon les besoins. Activé
Delta minimal de chauffage/
climatisation
La différence de température minimale entre la température désirée et la valeur dénie de
chauffage et climatisation en mode Auto. 15°C / 5°F
Programmation des phases
Programmation manuelle des phases, pour sélectionner et personnaliser des valeurs comme
le temps de dissipation, les deltas de température et les durées de fonctionnement de vos
équipements de chauffage et de climatisation. (voir *options de réglage manuel)
Automatique
Durée minimale d’arrêt du
compresseur La durée d’arrêt du compresseur entre les cycles. 300 secondes
Température extérieure minimale du
compresseur
Le compresseur de climatisation ou de thermopompe ne se mettra pas en marche sous cette
température extérieure.
Climatisation -
27°C / -35°F /
Thermopompe -
déni par l’utilisateur
Refroidissement maximal
duclimatiseur
Permet au climatiseur de se refroidir (au-dessus de la valeur dénie de refroidissement) à ce
niveau pour aider à réduire l’humidité. Désactivé
Durée d’activation minimale
duchauffage
La durée minimale pendant laquelle la fournaise/chaudière restera en marche pendant un
appel de chaleur. 5 minutes
Durée d’activation minimale
ducompresseur La durée minimale pendant laquelle le compresseur restera en marche. 5 minutes
Correction de la température Si le relevé du capteur du thermostat est incorrect, une correction peut être appliquée pour
obtenir un relevé précis. -18°C / +0°F
Correction de l’humidité Si le relevé du capteur du thermostat est incorrect, une correction peut être appliquée pour
obtenir un relevé précis. +0%
Protection thermique La différence minimale du relevé de température entre les capteurs qui déclenchera
l’algorithme pour ignorer le relevé inexact du capteur. Désactivé
Code de l’installateur Lorsque ce paramètre est activé, l’accès aux menus des paramètres d’installation est autorisée
lors de la saisie du code 3262. Désactivé
Systèmes de thermopompe seulement
Optimisation des économies
dusystème d’appoint
Ce paramètre simplie le passage de la thermopompe vers le chauffage d’appoint en fonction
des économies réalisées par rapport au confort. Un réglage de température plus élevé
favorisera les économies au détriment du confort.
16,5°C / 2°F
Température extérieure maximale du
chauffage d’appoint
Le chauffage d’appoint ne se mettra pas en marche si la température extérieure est supérieure
à la valeur dénie. 1,5°C / 35°F
Durée d’activation minimale
dusystème d’appoint
La durée minimale pendant laquelle le chauffage d’appoint restera en marche pendant un
appel de chaleur d’appoint. 5 minutes
Delta de température entre le
compresseur et le système d’appoint
Le nombre minimum de degrés entre la température actuelle et la valeur dénie avant
ledémarrage du chauffage d’appoint. Auto
Temps de fonctionnement
ducompresseur avant
systèmed’appoint
Le nombre minimum de minutes de fonctionnement du compresseur de thermopompe avant
de passer au chauffage d’appoint. Auto
Phase d’inversion du
systèmed’appoint
Lorsque le paramètre est activé, le chauffage d’appoint démarrera si la température actuelle
est supérieure à la valeur dénie dans le paramètre Delta de température entre le compresseur
etlesystème d’appoint.
Désactivé
*options de réglage manuel
Écart de température du chauffage L’écart de température minimum avant le démarrage du chauffage. -17,5°C / 0,5°F
Temps de dissipation de la chaleur La durée pendant laquelle le ventilateur restera en marche une fois le cycle de chauffageterminé. Auto
Écart de température de
laclimatisation L’écart de température minimum avant le démarrage de la climatisation. Auto
Temps de dissipation
durefroidissement
La durée pendant laquelle le ventilateur continuera à fonctionner une fois le cycle de
refroidissement terminé. Auto
Phase d’inversion du compresseur
Lorsque le paramètre est activé, la deuxième phase du compresseur démarrera si la
température actuelle est supérieure à la valeur dénie dans le paramètre Delta de température
de la deuxième phase du compresseur.
Désactivé
Delta de température de la phase 2
ducompresseur
Le nombre minimum de degrés entre la température actuelle et la valeur dénie avant
ledémarrage de la deuxième phase du compresseur. Auto
Durée maximale de la phase 1
ducompresseur
Le nombre maximum de minutes de fonctionnement de la phase 1 avant le démarrage de la
deuxième phase du compresseur. Auto
Phase d’inversion du chauffage
Lorsque le paramètre est activé, la deuxième phase du chauffage démarrera si la température
actuelle est supérieure à la valeur dénie dans le paramètre Delta de température de la
deuxième phase du chauffage.
Désactivé
Delta de température de la phase 2
du chauffage
Le nombre minimum de degrés depuis la valeur dénie avant le démarrage de la deuxième
phase du chauffage. Auto
Durée maximale de la phase 1
duchauffage
Le nombre maximum de minutes de fonctionnement de la phase 1 avant le démarrage de la
deuxième phase du chauffage. Auto
PARAMÈTRES DES ACCESSOIRES Menu > Paramètres > Paramètres d’installation > Équipement
NOM DU PARAMÈTRE DESCRIPTION VALEUR PAR DÉFAUT
Humidicateur
Évaporation ou condensation L’humidicateur à évaporation fonctionne avec un cycle de chauffage, tandis que l’humidicateur
à vapeur peut fonctionner avec ou sans cycle de chauffage. Déni par l’utilisateur
Delta minimum de fonctionnement L’humidicateur se mettra en marche pour la valeur dénie au-delà de la valeur d’humidité désirée. 5%
Efcacité des fenêtres Le paramètre du contrôle du gel utilise l’indice de rendement pour déterminer l’humidité
désirée dans une plage de 15 à 50 %. 2
Déshumidicateur
Déshumidicateur avec ventilation Lorsque ce paramètre est activé, la ventilation de la fournaise ou du système de traitement d’air
de met en marche pendant un appel de déshumidication. Oui
Delta minimum de fonctionnement Le déshumidicateur fonctionnera pour la valeur dénie au-delà de la valeur d’humiditédésirée. 5%
Déshumidicateur en modechauffage Permet au déshumidicateur de fonctionner de façon autonome du cycle de chauffage. Non
Déshumidicateur activé Ce paramètre dépend de l’exigence que le système CVC ou le déshumidicateur soit ouvert ou
fermé lorsqu’il est activé. Déni par l’utilisateur
Ventilateur
Aération préalable à la présence Active le fonctionnement du ventilateur une heure avant une présence planiée Désactivé
Température extérieure maximale de
climatisation libre
La climatisation libre ne se mettra pas en marche si la température extérieure est supérieure à
la valeur dénie 22°C / 72°F
Température extérieure maximale de
climatisation libre Température extérieure maximale pour le fonctionnement de la climatisation libre Désactivé
Delta entre températures intérieure/
extérieure
Permet la climatisation libre si la température intérieure par rapport à la température extérieure
est supérieure au delta de température. 16,5°C / 2°F
Delta de température
maximumdésirée
Delta maximum entre la température actuelle et la température désirée pour démarrer la
climatisation libre Désactivé
Aération préalable à la présence Active le fonctionnement du ventilateur une heure avant une présence planiée Désactivé
PARAMÈTRES DE RAPPEL ET D’ALERTES Menu > Rappels et alertes > Préférences
NOM DU PARAMÈTRE DESCRIPTION VALEUR PAR DÉFAUT
Entretien CCVC Intervalle d’entretien des systèmes de chauffage et de climatisation. Activé pendant 6 mois
Filtre de la fournaise La fréquence des rappels de ltre en fonction des mois ou des heures de fonctionnement. Activé pendant 3 mois
Lampe UV La fréquence d’entretien nécessaire en fonction des mois ou des heures de fonctionnement. Désactivé
Alerte de basse température Lorsque la température intérieure atteint ou est inférieure à cette valeur, une alerte est générée. Activé, 10°C / 50°F
Alerte de haute température Lorsque la température intérieure atteint ou est supérieure à cette valeur, une alerte estgénérée. Activé, 33°C / 92°F
Alerte de température extérieure
pourchauffage d’appoint
Une alerte sera générée si le chauffage d’appoint est utilisé à cette valeur ou à une
valeursupérieure. Désactivé
Alerte de mise en marche du
chauffaged’appoint
Une alerte sera générée si la durée de fonctionnement du chauffage d’appoint atteint ou
dépasse cette valeur dans une période de 24 h. Désactivé
Alerte de faible taux d’humidité Une alerte sera générée si le taux d’humidité est inférieur à cette valeur. Désactivé
Alerte de taux d’humidité élevée Une alerte sera générée si le taux d’humidité est supérieur à cette valeur. Désactivé
Afchage des alertes sur le thermostat Lorsque ce paramètre est activé, les alertes s’afchent sur l’écran du thermostat. Désactivé
Activation des alertes Chauffage/
Climatisation
Une alerte sera générée pour indiquer si le système a échoué à chauffer ou refroidir l’intérieur
delapièce. Activé
NOTE: G1, G2, G3 may also be labeled as GL, GM, GH
NOTE :
G1, G2, G3 peuvent
également être
identiés comme
GL, GM, GH
W1 W2 Y1 Y2 G R C
CLIMATISEUR
Y1 Y2 C
Rc
Rh
W1
W2
ACC+
ACC–
G
C
Y1
Y2
PEK+
OB
465-00396-RevB_Ares_Pro_Wiring-Guide_20220406