Please read these instructions carefully before using this product, and save this manual for future use.
7~15” S-Series HMI
Arm Cortex® A72 + Quad-core Cortex®-A53
Android 7.1
Model No.
W07RK3S-PCO1-POE
W07RK3S-PCO1AC-POE
W10RK3S-PCH2-POE
W10RK3S-PCH2AC-POE
R15RK3S-PCC3-POE
Quick Start Guide
Document Version 1.0
Document Part No. 915211101045
2
7~15" S-Series HMI Quick Start Guide
Contents
PREFACE 3
CHAPTER 1: INTRODUCTION 7
1.1 INTRODUCTION 8
1.2 PRODUCT FEATURES 8
1.3 UNPACKING 9
1.4 MECHANICAL DIMENSIONS 10
1.5 CONNECTOR DESCRIPTION 12
CHAPTER 2: GETTING STARTED 13
2.1 POWERING ON 14
2.2 CONNECTOR DESCRIPTION 15
2.3 CONFIGURING SERIAL PORT SETTING 18
CHAPTER 3: MOUNTING 20
3.1 CABLE MOUNTING CONSIDERATIONS 21
3.2 SAFETY PRECAUTIONS 21
3.3 MOUNTING GUIDE 21
CHAPTER 4: OPERATING THE DEVICE 29
4.1 HOME SCREEN 30
4.2 QUICK SETTINGS 31
4.3 ETHERNET 31
4.4 WINMATE® HOME MANAGER (WHM) 33
APPENDIX 38
APPENDIX A: PRODUCT SPECIFICATIONS 38
APPENDIX B: HF RFID READER SPECIFICATIONS 39
3
Preface
Preface
Copyright Notice
No part of this document may be reproduced, copied, translated, or transmitted in any form or
by any means, electronic or mechanical, for any purpose, without the prior written permission
of the original manufacturer.
Trademark Acknowledgement
Brand and product names are trademarks or registered trademarks of their respective owners.
Disclaimer
We reserve the right to make changes, without notice, to any product, including circuits and/or
software described or contained in this manual in order to improve design and/or performance.
We assume no responsibility or liability for the use of the described product(s) conveys no
license or title under any patent, copyright, or masks work rights to these products, and make
no representations or warranties that these products are free from patent, copyright, or mask
work right infringement, unless otherwise specified. Applications that are described in this
manual are for illustration purposes only. We make no representation or guarantee that such
application will be suitable for the specified use without further testing or modification.
Warranty
Our warranty guarantees that each of its products will be free from material and workmanship
defects for a period of one year from the invoice date. If the customer discovers a defect, we
will, at his/her option, repair or replace the defective product at no charge to the customer,
provide it is returned during the warranty period of one year, with transportation charges
prepaid. The returned product must be properly packaged in its original packaging to obtain
warranty service. If the serial number and the product shipping data differ by over 30 days, the
in-warranty service will be made according to the shipping date. In the serial numbers the third
and fourth two digits give the year of manufacture, and the fifth digit means the month (e. g.,
with A for October, B for November and C for December).
For example, the serial number 1W18Axxxxxxxx means October of year 2018.
Customer Service
We provide a service guide for any problem by the following steps: First, visit the website of
our distributor to find the update information about the product. Second, contact with your
distributor, sales representative, or our customer service center for technical support if you
need additional assistance.
You may need the following information ready before you call:
Product serial number
Software (OS, version, application software, etc.)
Description of complete problem
The exact wording of any error messages
In addition, free technical support is available from our engineers every business day. We are
always ready to give advice on application requirements or specific information on the
installation and operation of any of our products.
4
7~15" S-Series HMI Quick Start Guide
Advisory Conventions
Four types of advisories are used throughout the user manual to provide helpful information or to
alert you to the potential for hardware damage or personal injury. These are Notes, Important,
Cautions, and Warnings. The following is an example of each type of advisory.
Note:
A note is used to emphasize helpful information
Important:
An important note indicates information that is important for you to know.
Caution/ Attention
A Caution alert indicates potential damage to hardware and explains how to avoid
the potential problem.
Une alerte d’attention indique un dommage possible à l’équipement et explique
comment éviter le problème potentiel.
Warning!/ Avertissement!
An Electrical Shock Warning indicates the potential harm from electrical hazards
and how to avoid the potential problem.
Un Avertissement de Choc Électrique indique le potentiel de chocs sur des
emplacements électriques et comment éviter ces problèmes.
Safety Information
Warning!/ Avertissement!
Always completely disconnect the power cord from your chassis whenever you
work with the hardware. Do not make connections while the power is on. Sensitive
electronic components can be damaged by sudden power surges. Only
experienced electronics personnel should open the PC chassis.
Toujours débrancher le cordon d’alimentation du chassis lorsque vous travaillez
sur celui-ci. Ne pas brancher de connections lorsque l’alimentation est présente.
Des composantes électroniques sensibles peuvent être endommagées par des
sauts d’alimentation. Seulement du personnel expérimenté devrait ouvrir ces
chassis.
Alternating Current Mise à le terre !
The Protective Conductor Terminal (Earth Ground) symbol indicates the potential
risk of serious electrical shock due to improper grounding.
Le symbole de Mise à Terre indique le risqué potential de choc électrique grave
à la terre incorrecte.
5
Preface
For your safety carefully read all the safety instructions before using the device. Keep this user
manual for future reference.
Always disconnect this equipment from any AC outlet before cleaning. Do not use liquid or
spray detergents for cleaning. Use a damp cloth.
For pluggable equipment, the power outlet must be installed near the equipment and must
be easily accessible.
Keep this equipment away from humidity.
Put this equipment on a reliable surface during installation. Dropping it or letting it fall
could cause damage.
The openings on the enclosure are for air convection and to protect the equipment from
overheating.
Do not cover the openings.
Before connecting the equipment to the power outlet make sure the voltage of the power
source is correct.
Position the power cord so that people cannot step on it. Do not place anything over the
power cord.
If the equipment is not used for a long time, disconnect it from the power source to avoid
damage by transient over-voltage.
Never pour any liquid into an opening. This could cause fire or electrical shock.
Never open the equipment. For safety reasons, only qualified service personnel should
open the equipment.
All cautions and warnings on the equipment should be noted.
*Let service personnel to check the equipment in case any of the following
problems appear:
o The power cord or plug is damaged.
o Liquid has penetrated into the equipment.
o The equipment has been exposed to moisture.
o The equipment does not work well or you cannot get it to work according to
the user manual.
o The equipment has been dropped and damaged.
o The equipment has obvious signs of breakage.
Do not leave this equipment in an uncontrolled environment where the storage
temperature is below -20°C (-4°F) or above 60°C (140°F). It may damage the
equipment.
Caution/Attention
Use the recommended mounting apparatus to avoid risk of injury.
Utiliser l’appareil de fixation recommandé pour éliminer le risque de
blessure.
Warning!/ Avertissement!
Only use the connection cords that come with the product. When in doubt,
please contact the manufacturer.
Utiliser seulement les cordons d’alimentation fournis avec le produit. Si vous
doutez de leur provenance, contactez le manufacturier.
Warning!/ Avertissement!
Always ground yourself against electrostatic damage to the device.
Toujours vérifier votre mise à la terre afin que l’équipement ne se décharge
pas sur vous.
6
7~15" S-Series HMI Quick Start Guide
Cover workstations with approved anti-static material. Use a wrist strap connected
to a work surface and properly grounded tools and equipment.
Use anti-static mats, heel straps, or air ionizer for added protection.
Avoid contact with pins, leads, or circuitry.
Turn off power and input signals before connecting test equipment.
Keep the work area free of non-conductive materials, such as ordinary plastic
assembly aids and Styrofoam.
Use filed service tools, such as cutters, screwdrivers that are conductive.
Always put drivers and PCB’s component side on anti-static foam.
Important Information
Federal Communications Commission Radio Frequency Interface Statement
This device complies with part 15 FCC rules.
Operation is subject to the following two conditions:
This device may not cause harmful interference.
This device must accept any interference received including
interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a class "B" digital
device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to correct the interference
at him own expense.
EC Declaration of Conformity
This equipment is in conformity with the requirement of the
following EU legislations and harmonized standards. Product also
complies with the Council directions.
Electromagnetic Compatibility Directive (2014/30/EU)
EN55024: 2010 EN 55022: 2010 Class B
o IEC61000-4-2: 2009
o IEC61000-4-3: 2006+A1: 2007+A2: 2010
o IEC61000-4-4: 2012
o IEC61000-4-5: 2014
o IEC61000-4-6: 2013
o IEC61000-4-8: 2010
o IEC61000-4-11: 2004
EN55022: 2010/AC:2011
EN61000-3-2:2014
EN61000-3-3:2013
Low Voltage Directive (2014/35/EU)
EN 60950-1:2006/A11:2009/A1:2010/A12:2011/ A2:2013
7
Chapter 1: Introduction
Chapter 1: Introduction
This chapter gives you product overview, describes features and
hardware specification. You will find all accessories that come
with the HMI in the packing list. Mechanical dimensions and
drawings included in this chapter.
8
7~15" S-Series HMI Quick Start Guide
1.1 Introduction
Congratulations on purchasing Winmate® S-Series HMI. Winmate continues developing new
generation of Human Machine Interfaces for Industry 4.0 and Internet of Things (IoT).
Our S-Series HMI runs on Android 7.1 operating system that allows installing the latest
applications (APPs). There are two USB connectors, USB 3.0 and USB 2.0, onboard to connect
mouse or keyboard and one micro USB OTG for system updates. System memory LPDDR3L of 2
GB ensures stable operation of applications. The HMI devices features P-Cap touchscreen and
have front side IP65 dust and water protection. The HMI devices support an exceptional feature -
LED status light bar. Red, green and blue LED indicators show the status of the machine or
processes afar. It significantly reduces power consumption by keeping the display turned off.
The S-Series HMI is suitable for home automation and room management systems. Flat surface is
easy-to-clean and delivers aesthetically pleasing look for any interior. By connecting to centralized
database, it can provide real time update for booking status and available schedule, or perform as
a synchronous display in meetings. Optional RFID reader is especially useful in access control
applications.
1.2 Product Features
Winmate® S-Series HMI features:
7/ 10.1/ 15.6-inch widescreen panel
Projected capacitive multitouch screen
Arm Cortex® A72 + Quad-core Cortex®-A53
Android 7.1 operating system
1 x USB 3.0, 1 x USB 2.0, PoE IEEE 802.3at (25 W), IEEE 802.3af (15 W)
Fanless cooling system and ultra-low power consumption
Front IP65 water and dust proof, rear IP22
Light design for machine automation, smart factory and IoT applications
9
Chapter 1: Introduction
1.3 Unpacking
Carefully remove the box and unpack your HMI device. Please check if all the items listed below
are inside your package. If any of these items are missing or damaged contact us immediately.
Standard factory shipment list:
HMI Device
Quick Start Guide
(Hardcopy)
Driver CD & User Manual
Varies by product specifications
Part No. 915211101045
Varies by product specifications
AC Adapter (12V/ 50W)
Power Cord
3 pin Terminal Block to DC
Jack
Part No. 922D050W12VA
Varies by country
Part No. 94J602G030K0
Package may include optional accessories based on your order
VESA Desk Stand
PCVS-V1
VESA Desk Stand
LA-100
VESA Wall Mount
Bracket LA-106
Front Side Wall
Mount PCFW-V1
Part No. 99KK00A0000E
Part No. 9B0000000128
Part No. 9B0000000412
Part No. 99KK00A0000C
For installation instructions and dimensions of optional accessories refer to Ch.3, “Mounting
Guide”.
10
7~15" S-Series HMI Quick Start Guide
1.4 Mechanical Dimensions
This section describes appearance, connectors’ layout and mechanical dimensions of S-Series
HMI. Notice that this is a simplified drawing and some components are not marked in detail.
Please contact our sales representative if you need further product information.
7-inch, W07RK3S-PCO1-POE
Unit: mm
Dimensions:189.4 x 145.4 x 36.1
7-inch, W07RK3S-PCO1AC-POE
Unit: mm
Dimensions:189.4x 145.4x 36.1
11
Chapter 1: Introduction
10.1-inch, W10RK3S-PCH2-POE
Unit: mm
Dimensions:263.48 x 172 x 35.7
10.1-inch, W10RK3S-PCH2AC-POE
Unit: mm
Dimensions:263.48 x 172 x 35.7
12
7~15" S-Series HMI Quick Start Guide
15.6-inch, R15RK3S-PCC3-POE
Unit: mm
Dimensions:363.4 x 277 x 86 x 44.5
1.5 Connector Description
Terminal interfaces are located on the bottom side of the HMI device.
Note:
Notice that input and output connectors vary by product size and specifications.
Terminal interfaces description:
Item
Description
RJ45 Connects HMI device to Ethernet network. Supports PoE for
power transmission in network equipment, via network UTP cable,
together with data.
Terminal Block Provides power to the HMI device, accepts 12V DC.
Example: AC cord or DC power supply. If both are provided, choose only
one.
RS-232/422/485 Connects external devices to HMI device.
Example: A barcode reader or scanner to HMI device.
USB 3.0, USB 2.0- Connects USB 3.0/ USB 2.0 compatible devices to
HMI device.
Example: A printer to HMI device.
Micro HDMI Transmits video from HMI device to external monitor.
Example: An external monitor to HMI device.
USB OTG Connect to PC for client use and update OS Image.
MicroSD Card Slot Insert microSD card to expand the storage.
13
Chapter 2: Getting Started
Chapter 2: Getting Started
This chapter tells you important information on power supply, adapter
and precautions tips. Pay attention to power considerations.
14
7~15" S-Series HMI Quick Start Guide
2.1 Powering On
2.1.1 AC Adapter Components
Safety Precautions:
Do not use the adapter in a high moisture environment
Never touch the adapter with wet hands or foot
Allow adequate ventilation around adapter while using
Do not cover the adapter with paper or other objects that will reduce cooling
Do not use the adapter while it is inside a carrying case
Do not use the adapter if the cord is damaged
There are NO serviceable parts inside
Replace the unit if it is damaged or exposed to excess moisture
While using the AC Adapter always:
Plug-in the power cord to easy accessible AC outlet
Plug-in the AC adapter to a grounded outlet
2.1.2 Power Considerations
The HMI device operates on external DC power. Use the AC adapter included in the package.
Caution/ Attention
Use only the AC adapter included in your package
(Rating: Output 12 V/ 6.6A). Using other AC adapters may damage the device.
Utiliser seulement le convertisseur AC avec votre appareil (Puissance: Sortie 12 V/
6.6A). Utilizer d’autres convertisseurs pourraient endommager l’appareil.
AC Adapter
Power Cord
3 Pin Terminal Block
to DC Jack
Alternating Current/ Mise à le terre !
This product must be grounded. Use only a grounded AC outlet. Install the
additional PE ground wire if the local installation regulations require it.
*If you do not use a grounded outlet while using the device, you may notice an
electrical tingling sensation when the palms of your hands touch the device.
[FR]Ce produit doit être mis à la terre. Utiliser seulement un cordon
d’alimentation avec mise à la terre. Si les règlements locaux le requiert, installer
des câbles de mise à la terre supplémentaires.
*Si vous n’utilisez pas une prise d’alimentation avec mise à la terre, vous
pourriez remarquer une sensation de picotement électrique quand la paume de
vos mains touche à l’appareil.
15
Chapter 2: Getting Started
2.1.3 Connecting the Power
Installation Instruction:
1. Connect a 3-pin terminal block to the HMI connector.
2. Connect the other side of the terminal block to the AC adapter.
3. Connect the AC adapter to the power cord.
4. Plug in the power cord to a working AC wall outlet. The device will boot automatically.
2.2 Connector Description
2.2.1 Power Input Connector
The DC power source input of the panel PC is a 3 pin terminal block connector that supports
12V DC power input.
Pin assignment and connector description of terminal block connector.
Note:
Based on the model, terminal block connector may be located either on the bottom
or on the rear side of the HMI device.
Note:
Power cords vary in appearance by region and country.
Voltage
Minimum Voltage 11.4V
Maximum Voltage 12.6V
Maximum Current 4.2A
16
7~15" S-Series HMI Quick Start Guide
2.2.2 Ethernet Connector
The HMI device supports one RJ45 10/100/1000 Mbps Ethernet interface for connecting to the
internet.
Pin assignment and connector description of RJ45 connector.
2.2.3 Serial Port Connector
The S-Series HMI has one serial port connector to connect your HMI to external devices such as mouse,
modem or printer. You can configure serial port settings via APP.
Pin assignment and connector description of serial port connector.
*Default setting: RS-232
2.2.4 USB Connector
The HMI device has one USB 2.0 and one USB 3.0 connectors. Use USB 2.0 and USB 3.0
connector to connect your HMI device to other USB 2.0/ USB 3.0 compatible devices.
Pin assignment and connector description of USB connector.
Pin №
Signal Name
Pin №
Signal Name
1
TX1+
2
TX1-
3
TX2+
4
TX2-
5
TX3+
6
TX3-
7
TX4+
8
TX4-
Pin
*RS-232
RS-422
RS-485
1
DCD
TxD-
D-
2
RXD
TxD+
D+
3
TXD
RxD+
NC
4
DTR
RxD-
NC
5
GND
GND
GND
6
DSR
NC
NC
7
RTS
NC
NC
8
CTS
NC
NC
9
RI
NC
NC
Pin №
Signal Name
Pin №
Signal Name
1
+5V
2
USB_D-
3
USB_D+
4
GND
5
STDA_SSRX-
6
STDA_SSRX+
7
GND_DRAIN
8
STDA_SSTX-
9
STDA_SSTX+
10
+5V
11
USB_D-
12
USB_D+
13
GND
17
Chapter 2: Getting Started
2.2.5 Micro HDMI Connector
The HMI device has one micro HDMI connector. Use micro HDMI cable to connect your HMI
device to external monitor or other peripheral.
Pin assignment and connector description of micro HDMI connector.
2.2.6 USB OTG Connector
Use USB OTG connector to connect the panel PC to other USB On-The-Go compliant devices
such as flash drives, digital cameras, mice or keyboards. Use USB OTG cable to install software
on the panel PC.
Pin assignment and connector description of USB OTG connector.
Refer to Ch.5 of this user manual for more details on how to install software
2.2.7 Micro SD Card Slot
Insert microSD card to microSD card slot to extend the memory of your HMI device.
Pin assignment and connector description of micro SD card slot.
Pin
Signal Name
Pin
Signal Name
1
HP_DET_OUT
2
NC
3
HDMI_D2P
4
GND
5
HDMI_D2M
6
HDMI_D1P
7
GND
8
HDMI_D1M
9
HDMI_D0P
10
GND
11
HDMI_D0M
12
HDMI_CLKP
13
GND
14
HDMI_CLKM
15
HDMI_CEC_OUT
16
GND
17
H_CLK_OUT
18
H_DAT_OUT
19
HDMI_5V
Pin №
Signal Name
Pin №
Signal Name
1
+5V
2
USB_OTG_D-
3
USB_OTG_D+
4
USB_OTG_ID
5
GND
Pin №
Signal Name
Pin №
Signal Name
1
DATA2
2
DATA3
3
CMD
4
+3.3V
5
CLK
6
GND
7
DATA0
8
DATA1
9
Card_Det
18
7~15" S-Series HMI Quick Start Guide
2.3 Configuring Serial Port Setting
Serial port setting can be configured for RS-232, RS-422 or RS-485. Winmate provide serial port settings
application for Android OS.
To configure serial port settings:
1. Settings > Accessibility.
2. Accessibility > System: Comport-Setting.
19
Chapter 2: Getting Started
3. Comport-Setting > Comport 1/ Comport 2/ Comport 3
* Select Comport 1/ Comport 2/ Comport 3 that you want to configure.
4. Comport 1 > RS232/RS422/RS485
* Configure Comport 1 settings
20
7~15" S-Series HMI Quick Start Guide
Chapter 3: Mounting
This chapter provides mounting guide for all available mounting
options. Pay attention to cautions and warning to avoid any
damages.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

dans d''autres langues