Automate Li-ion 3.0 35mm Motor Manuel utilisateur

Taper
Manuel utilisateur
Li-ion & DC Motor
MOTOR PROGRAMMING INSTRUCTIONS
SOFT STOP
SOLAR OPTION
FAVORITE
POSITION
SELECTABLE
SPEED
BATTERY
POWERED
USB CHARGE
(Only for Li-ion Motor)
ELECTRONIC
LIMIT
LEVEL CONTROL
BATTERY CHECK433 MHZ
BI-DIRECTIONAL
AUTOMATE 5V ZERO & WIREFREE V1.0_PRGM_JULY_2022
Fav Position
Live Feedback
Energy ecient
2 | Automate Programming Instructions | Li-ion & DC Motors ROLLEASE ACMEDA
SAFETY INSTRUCTIONS
WARNING: Important safety instructions to be read before installation.
Incorrect installation can lead to serious injury and will void manufacturer’s liability and warranty.
WARNING: Important safety instructions to be read before installation and use.
It is important for the safety of persons to follow the enclosed instructions. Save these instructions for future reference.
WARNING: Incorrect installation or use can lead to serious injury and will void manufacturer’s liability and warranty.
Read and follow all installation and safety instructions.
This manual is also available on the website.
Do not expose to water, moisture, humid and damp
environments or extreme temperatures.
Use or modification outside the scope of this instruction manual
will void warranty.
This appliance can be used by children aged 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning the use of the
appliance in a safe way and understand the hazards involved.
Children should not play with the appliance. Cleaning and user
maintenance should not be performed by children without
supervision.
Do not allow children to play with fixed controls. Keep appliance
and remote controls away from children.
Assembly, installation and programming must be performed by
a suitably qualified installer.
For use with motorized shading devices.
Frequently inspect the installation for improper operation, signs
of wear, imbalance or damage to cables or springs. Do not use if
repair or adjustment is necessary.
The appliance must be disconnected from its power source
during cleaning, maintenance or when replacing parts.
Maintenance and parts replacement should be performed by a
suitably qualified installer/technician.
The A-weighted emission sound pressure level of the appliance
is less than or equal to 70dB(A).
The appliance is for indoor use only.
Disconnect the appliance from power or switch off automatic
controls when maintenance, such as window cleaning, is being
carried out in the vicinity.
The appliance must be supplied only the safe, extra-low voltage
corresponding to the marking on the appliance.
Keep clear of the appliance when in operation.
There are no user serviceable parts or batteries inside the
appliance.
Remote batteries should be replaced with the correctly specified
type only.
The mass and dimensions of the driven part must be compatible
with the rated torque and rated operating time of the appliance.
The driven part must be compatible with the rated torque and
operating time of the appliance as follows:
For 0.5Nm motor series (MT01-1320-069001 and similar):
Rated torque of 0.5Nm, rated operating time of 12 minutes and
minimum tube diameter of ø20mm.
For 1.1Nm motor series (MT01-1325-069002, MT01-1225-069002
and similar): Rated torque of 1.1Nm, rated operating time of 12
minutes and minimum tube diameter of ø25mm.
For 2.0Nm motor series (MT01-1328-069001, MT01-1228-069002
and similar): Rated torque of 2.0Nm, rated operating time of 12
minutes and minimum tube diameter of ø28mm.
Fixed controls have to be clearly visible after installation.
The appliance is intended to be installed at a height of at least
2.5m above the floor or any other accessible level surface.
Before installing the appliance, remove any unnecessary cords
or components and disable any equipment not needed for
powered operation.
ROLLEASE ACMEDA Automate Programming Instructions | Li-ion & DC Motors | 3
COMPLIANCE STATEMENT
This device complies with Part 15 of the FCC Rules / Industry Canada
licence-exempt RSS standard(s). Operation is subject to the following
two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including
interference that may cause undesired operation.
Le présent appareil est conforme aux CNR d’Industrie Canada
applicables aux appareils radio exempts de licence. L’exploitation est
autorisée aux deux conditions suivantes:
(1) l’appareil ne doit pas produire de brouillage, et
(2) l’utilisateur de l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate
the equipment.
This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or
more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
To satisfy FCC / IC RF exposure requirements, a separation distance of
20 cm or more should be maintained
between the antenna of this device and persons during device
operation.
To ensure compliance, operations at closer than this distance is not
recommended.
Les antennes installées doivent être situées de facon à ce que la
population ne puisse y être exposée à une distance de moin de 20
cm. Installer les antennes de facon à ce que le personnel ne puisse
approcher à 20 cm ou moins de la position centrale de l’ antenne.
La FCC des éltats-unis stipule que cet appareil doit être en tout temps
éloigné d’au moins 20 cm des personnes pendant son functionnement.
Do not dispose of in general waste.
Please recycle batteries and damaged
electrical products appropriately.
4 | Automate Programming Instructions | Li-ion & DC Motors ROLLEASE ACMEDA
CONTENTS
1 ASSEMBLY 5
2 RETROFIT INSTALLATION 6
3 CHARGING/POWER SUPPLY 6
4 P1 BUTTON FUNCTIONS 7
4.1 Motor state test 7
4.2 Motor configuration options 7
5 INITIAL SET UP 8
5.1 Pair motor with controller 8
5.2 Check motor direction 8
5.3 Set Limits 9
6 ADJUSTING LIMITS 10
6.1 Adjust upper limit 10
6.2 Adjust lower limit 10
7 CONTROLLERS AND CHANNELS 11
7.1 Using P2 Button on existing controller to add a
new controller or channel 11
7.2 Using a pre-existing controller to add or delete
a controller or channel 11
8 FAVORITE POSITIONING 12
8.1 Set a favorite position 12
8.2 Send shade to favorite position 12
8.3 Delete favorite position 12
9 TILT & ROLLER MODE 13
9.1 Toggle motor to Tilt Mode 13
9.2 Toggle Motor to Roller Mode 13
10 ADJUSTING SPEED 14
10.1 Increase Motor Speed 14
10.2 Decrease Motor Speed 14
11 SOFT STOP CONFIGURATION 15
11.1 Turn Soft Stop OFF 15
11.2 Turn Soft Stop ON 15
12 BATTERY CHECK FUNCTION 16
12.1 Send Shade to battery charge level 16
13 CHARGING LED 16
13.1 Turn Charging LED ON/OFF 16
14 SLEEP MODE 17
15 TROUBLE SHOOTING 18
16 NOTES 20
ROLLEASE ACMEDA Automate Programming Instructions | Li-ion & DC Motors | 5
1 ASSEMBLY
ZERO HEAD ADAPTER
ZERO HEAD ANTENNA WRAP
GENERIC CROWN, DRIVE & TUBE ASSEMBLY
6 | Automate Programming Instructions | Li-ion & DC Motors ROLLEASE ACMEDA
3 CHARGING/POWER SUPPLY
2 RETROFIT INSTALLATION
(1.1Nm & 2.0Nm MOTOR ONLY)
(LI-ION 1.1Nm & 2.0Nm ONLY) (LI-ION 3.0Nm & 10.0Nm ONLY) (DC 1.1Nm & 2.0Nm ONLY)
Requries a continuous 12V DC Power Source.
ROLLEASE ACMEDA Automate Programming Instructions | Li-ion & DC Motors | 7
4.1 Motor state test
4.2 Motor configuration options
This table describes the function of a short P1 Button press/release (<2 seconds) depending on current motor
configuration.
The P1 Button is utilized to administer motor configurations as described below.
Activate Pairing Mode
Approx.
Approx.
Approx.
Sleep Mode
Reverse Direction
Approx.
Reset To Factory Settings
Approx.
Approx.
4 P1 BUTTON FUNCTIONS
P1
Press Condition Function
Achieved
Visual
Feedback
Audible
Feedback Function Described
Short
Press
If limit is NOT set None No Action None No Action
If limits are set
Operational
control of motor,
run to limit. Stop
if running
Motor Runs None
Operational control
of motor after pairing
and limit setting is
completed first time
If motor is in
“Sleep Mode” &
limits are set
Wake and control
Motor wakes
and runs in a
direction
None
Motor is restored from
Sleep Mode and RF
control is active
Hold P1 button on motor head.
P1 button on motor head.
10
10
Approx.
Approx.
Approx.
Approx.
8 | Automate Programming Instructions | Li-ion & DC Motors ROLLEASE ACMEDA
5.1 Pair motor with controller
5.2 Check motor direction
.
Consult user manual for your
controller for information on
selecting channel.
Damage to shade may occur when operating motor prior to
setting limits. Attention should be given.
Reversing motor direction using this method is only possible
during initial set-up
Hold P1 button on
motor head.
To check travel direction of shade, press UP or
DOWN on controller.
Quick Press = Step
Long Press = Continuous Travel
To reverse shade direction, hold both UP and
DOWN.
Until the motor responds.
Select channel on
controller.
Hold STOP on
controller.
Approx.
Approx.
Motor Response
Motor Response
Motor Response
Motor is now in step mode and ready for setting limits
IMPORTANT
IMPORTANT
IMPORTANT
5 INITIAL SET UP
OR
ROLLEASE ACMEDA Automate Programming Instructions | Li-ion & DC Motors | 9
SEC
SEC
S
S
5
5
Cycle shade up and down prior to setting limits to settle fabric
After setting limits, motor will automatically exit from initial
set-up mode.
Move shade to the desired highest or lowest
position by pressing the UP or DOWN buttons
on controller.
Move shade to the desired highest or lowest
position by pressing the UP or DOWN buttons
on controller.
To save upper limit, hold UP and STOP.
To save lower limit, hold DOWN and STOP.
Motor Response
Motor Response
IMPORTANT
IMPORTANT
Approx.
Approx.
OR
OR
5.3 Set Limits
10 | Automate Programming Instructions | Li-ion & DC Motors ROLLEASE ACMEDA
SEC
SEC
S
S5
5
Hold UP and STOP on
controller.
Hold DOWN and STOP
on controller.
Move shade to the desired
lowest position by pressing
the UP or DOWN button.
Move shade to the desired
highest position by pressing
the UP or DOWN button.
To save upper limit, hold UP
and STOP.
To save lower limit, hold
DOWN and STOP.
Approx.
Approx.
Motor Response
Motor Response Motor Response
Motor Response
6 ADJUSTING LIMITS
SEC SECS S
5 5
Approx. Approx.
The bottom limit should be set ~ 1.38 in. (35mm) below the Ultra-Lock to disengage the auto lock mechanism when the shade is raised.
IMPORTANT
OR
OR
6.1 Adjust upper limit
6.2 Adjust lower limit
ROLLEASE ACMEDA Automate Programming Instructions | Li-ion & DC Motors | 11
A = Existing controller or channel (to keep)
B = Controller or channel to add or remove
A = Existing controller or channel (to keep)
B = Controller or channel to add or remove
Press P2 on
controller A.
Press P2 on
controller A.
Press P2 on
controller A.
Press P2 on
controller A.
Press P2 on the
controller B to remove
it.
Press STOP on an new
controller to add it.
Motor Response
Motor Response
Motor Response
Motor Response
Motor Response
Motor Response
7 CONTROLLERS AND CHANNELS
Consult user manual for your controller or sensor
Consult user manual for your controller or sensor
IMPORTANT
IMPORTANT
7.1 Using P2 Button on existing controller to add a new controller or channel
7.2 Using a pre-existing controller to add or delete a controller or channel
12 | Automate Programming Instructions | Li-ion & DC Motors ROLLEASE ACMEDA
Press P2 on controller. Press STOP on controller. Press STOP on controller.
Move shade to the desired position by pressing the UP or DOWN button on the controller.
Press P2 on controller. Press STOP on controller. Press STOP on controller.
Approx.
Motor Response
Motor Response
Motor Response
Motor Response
Motor Response
Motor Response
8 FAVORITE POSITIONING
OR
8.1 Set a favorite position
8.2 Send shade to favorite position
8.3 Delete favorite position
ROLLEASE ACMEDA Automate Programming Instructions | Li-ion & DC Motors | 13
9 TILT & ROLLER MODE
Press STOP on controller.
Hold UP & DOWN on controller.
Hold UP & DOWN on controller.
Press STOP on controller.
Motor Response
Motor Response
Motor Response
Motor Response
Default motor mode is Roller after initial Limits have been set, use following steps to change to Roller Mode.
If motor is in Tilt Mode, use following steps to change to Roller Mode.
SEC
SEC
S
S
5
5
Approx.
Approx.
9.1 Toggle motor to Tilt Mode
9.2 Toggle Motor to Roller Mode
14 | Automate Programming Instructions | Li-ion & DC Motors ROLLEASE ACMEDA
10 ADJUSTING SPEED
Press P2 Press DOWN Press DOWN
Motor Response Motor Response Motor Response
Press P2 Press UP Press UP
Motor Response Motor Response Motor Response
Default motor mode is the slowest speed.
10.1 Increase Motor Speed
10.2 Decrease Motor Speed
ROLLEASE ACMEDA Automate Programming Instructions | Li-ion & DC Motors | 15
11 SOFT STOP CONFIGURATION
Press P2 Press DOWN Press DOWN
Motor Response Motor Response Motor Response
Press P2 Press UP Press UP
Motor Response Motor Response Motor Response
Motor must be in slowest speed to turn Soft Stop OFF.
Motor must be in fastest speed to turn Soft Stop ON.
11.1 Turn Soft Stop OFF
11.2 Turn Soft Stop ON
16 | Automate Programming Instructions | Li-ion & DC Motors ROLLEASE ACMEDA
12 BATTERY CHECK FUNCTION
Hold UP
Motor Response Shade must be at Upper Limit
Hold UP for Approx. 5s
Shade must be at Upper Limit.
Shade moves to percentage of
battery charge remaining
SEC
5
Approx.
13 CHARGING LED
Hold DOWN to toggle off
Red LED flashes x3 Red LED flashes x3
Hold DOWN to toggle on
Motor Response Motor Response
SEC SEC
5 5
Approx. Approx.
Motor must be at Lower Limit.
Motor is fully charged
Motor is charging. Battery is
greater than 50%.
Motor is charging. Battery is
lower than 50%.
Upper Limit Percentage of
Battery Charge
Remaining
Percentage Depleted
Lower Limit
S
S
12.1 Send Shade to battery charge level
13.1 Turn Charging LED ON/OFF
(ONLY FOR LI-ION MOTORS)
SOLID GREEN
BLINKING GREEN
BLINKING GREEN & RED
CHARGING LED STATUS
NOTE: This feature is can only be used with a DC motor when it is using a Barrery Pack as its power source.
ROLLEASE ACMEDA Automate Programming Instructions | Li-ion & DC Motors | 17
9 SLEEP MODE
Enter Sleep Mode
Sleep mode is utilized to
prevent a motor from incorrect
configuration during other
motor setup.
Hold P1 button on the motor
head
If multiple motors are grouped on a single channel, Sleep Mode may be used to put all but 1 motor to sleep,
allowing programming of just the one motor that remains “Awake”. See page 6 for detailed P1 functions.
Exit Sleep Mode: Method 1
Exit sleep mode once the shade
is ready.
Press and release P1 button on
the motor head
Exit Sleep Mode: Method 2
Remove power and then
re-power the motor.
Motor Response Motor Response
14 SLEEP MODE
Approx.
18 | Automate Programming Instructions | Li-ion & DC Motors ROLLEASE ACMEDA
ROLLEASE ACMEDA | AUSTRALIA
110 Northcorp Boulevard,
Broadmeadows VIC 3047, AUS
T +61 3 9355 0100 | F +61 3 9355 0110
ROLLEASE ACMEDA | USA
Level 7 / 750 East Main Street
Stamford, CT 06902, USA
T +1 800 552 5100 | F +1 203 964 0513
ROLLEASE ACMEDA | EUROPE
Via Conca Del Naviglio 18,
Milan (Lombardia) Italy
T +39 02 8982 7317 | F +39 02 8982 7317
G
15 TROUBLE SHOOTING
Problem Cause Remedy
Motor is not responding Battery in motor is depleted or
Power Supply is not working
Recharge with a compatible
charger
Insufficient charging from solar
PV panel
Check connection and orientation
of PV panel
Transmitter battery is discharged Replace battery
Battery is inserted incorrectly
into transmitter
Check battery polarity
Radio interference/shielding Ensure transmitter is positioned
away from metal objects and
the aerial on motor or receiver
is kept straight and away from
metal
Receiver distance is too far from
transmitter
Move transmitter to a closer
position
Charging failure Check power supply to motor is
connected and active
Motor beeps x10 when in use Battery voltage is low Recharge with a compatible
charger
Cannot program a single motor
(multiple motors respond)
Multiple motors are paired to the
same channel
Always reserve an individual
channel for programming
functions. Use Sleep Mode to
program individual motors.
automateshades.com
ROLLEASE ACMEDA Automate Programming Instructions | Li-ion & DC Motors | 19
16 NOTES
20 | Automate Programming Instructions | Li-ion & DC Motors ROLLEASE ACMEDA
16 NOTES
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Automate Li-ion 3.0 35mm Motor Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues