Friedrich MRM09Y1J Mode d'emploi

Catégorie
Aspirateurs
Taper
Mode d'emploi

Ce manuel convient également à

Models
Indoor Unit
Outdoor Unit
MWM09Y1J MWM
12Y1J
MRM09Y1J MRM12Y1J
960-910-05
CONTENTS
This symbol stands for the items
should be forbidden.
This symbol stands for the items
should be followed
...............................................................1
......................................................10
...................................................12
..........................................17
...........................21
.....................................................16
.....................................................11
Operation and maintenance
Notices for use
Names and functions of each part
........................................3
Operation of remote controller
.............................................4
Emergency operation
Routine Maintenance
Basic Troubleshooting
Installation service
Notices for installation
Installation dimension diagram
Install indoor unit
Install outdoor unit
Check after installation and test operation
Do not dispose of this product as unsorted municipal
waste. Collection of such waste separately for special
treatment is necessary.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
............................................................19
.........................................................20
Thank you for choosing
Friedrich Air Conditioning
, please read this owner's manual
carefully before operating the unit and keep it carefully for consulation.
Service & Assistance
....................................................14
Service & Assistance
.....................................................15
Congratulations
Thank you for your decision to purchase Friedrich. Your new Friedrich has been carefully engineered and manufactured to give you many years of dependable,
efcient operation, maintaining a comfortable temperature and humidity level. Many extra features have been built into your unit to assure quiet operation,
the greatest circulation of cool, dry air, and the most economic operation.
General Instructions
This Installation and Operation Manual has been designed to insure maximum satisfaction in the performance of your unit. For years of trouble-free service,
please follow the installation instructions closely. We cannot overemphasize the importance of proper installation.
Here are some suggestions to help you use your
new Friedrich most efficiently:
1. Carefully read and follow the installation instructions.
2. Make sure the unit is the right capacity for the area being cooled.
An undersized unit makes the unit work too hard, using more
electricity than needed and increases wear. An oversized unit
will cycle on and off too rapidly, and therefore cannot control
humidity as well.
3.
Clean the filter frequently (See Routine Maintenance, Page 23).
4. Do not block the air ow to and from the unit.
5. A dirty lter or improperly set controls can affect the cooling
ability of the unit.
6. If cooling is weak and you have veried that the lter is clean
WARNING
Read Installation Operation
Manual
Please read this manual thoroughly prior to
equipment installation or operation.
It is the installer’s responsibility to properly
apply and install the equipment. Installation
must be in conformance with the NFPA 70
-2008 National Electric Code or current edition,
International Mechanic Code 2009 or current
edition and any other applicable local or
national codes.
Failure to do so can result in property damage,
personal injury or death.
WARNING
Refrigeration system
under high pressure
Do not puncture, heat, expose to flame or
incinerate.
Only certified refrigeration technicians should
service this equipment.
Only use gauge sets designed for use with
R410A. Do not use standard R22 gauge sets.
R410A systems operate at higher pressures
than R22 equipment. Appropriate safe
service and handling practices must be used.
and the controls are properly set, the unit may need service and
you should call your Friedrich service provider to check the unit.
7. Keep blinds, shades and drapes closed on the sunny side of the
room being cooled to reduce radiant heat.
8. Proper insulation helps your unit maintain the desired inside
temperature.
9. Whenever possible, shade south and west facing windows.
10. Keep window coverings away from the unit to provide free air ow.
NOTICE
CAUTION
ANIN
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all
safety messages.
This is a safety Alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol with the word “WARNING”
or “CAUTION”. These words mean:
Indicates a hazard which, if not avoided, can result in severe personal injury or
death and damage to product or other property.
Indicates a hazard which, if not avoided, can result in personal injury and
damage to product or other property.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you
what will happen if the instructions are not followed.
Indicates property damage can occur if instructions are not followed.
WARNING
.
Anti-cool wind function:
In "Heat" mode, under the following three kinds of state, if indoor heat exchanger doesn't
arrive at certain temp., indoor fan will not act, in order to prevent cool wind blowing(within
2 mins):
1. Heating starts. 2.After Auto Defrost finished. 3.Heating under the low temperature.
Gentle Breeze
In the following situation, the indoor unit may blow gentle breeze, and
the guide louver rotate to a certain position:
1. In “Heat” mode, the unit turned on, the compressor doesn’t arrive the starting condition
2. In “Heat” mode, the temperature arrive at the setting value and the compressor stop
running about 1min.
*
*
*
*
*
*
Notices for use
Working principle and special functions for cooling
Principle:
Anti-freezing function:
Working principle and special functions for heating
Principle:
Defrosting:
Air conditioner absorbs heat in the room and transmit to outdoor and discharged, so that
indoor ambient temperature decreased, its cooling capacity will increase or decrease by
outdoor ambient temperature.
If the unit is running in COOL mode and in low temperature, there will be frost formed on
the heat exchanger, when indoor heat exchanger temperature decreased below 0 , the
indoor unit microcomputer will stop compressor running and protect the unit.
Air conditioner absorbs heat from outdoor and transmits to indoor, in this way to increase
room temperature. This is the heat pump heating principle, its heating capacity will be
reduced due to outdoor temperature decrease.
If outdoor temperature becomes very low, please operate with other heating equipments.
When outdoor temperature is low but high humidity, after a long while running, frost will
form on outdoor unit, that will effect the heating effect, at this time, the auto defrosting
function will act, the heat running will stop for 8-10mins.
During the auto defrosting, the fan motors of indoor unit and outdoor unit will stop.
During the defrosting, the indoor indicator flashes, the outdoor unit may emit vapor.
This is due to the defrosting, it isn't malfunction.
After defrosting finished,the heating will recover automatically.
1
2
Notices for use
Working temperature range
Maximum cooling
Maximum heating
Indoor side DB/WB(ºF)
90/73
81/---
Outdoor side DB/WB(ºF)
109/79
75/64
The operating temperature range (outdoor) heat pump unit is 5ºF~ 109ºF. 115V
Model
Air
out
Air in
Run
Receive
Heat
Cool
Dry
SET TEMP
ON/OFF
3
Names and functions of each part
Indoor unit
Outdoor unit
Wireless
remote control
Guide louver
Drainage pipe
Air inlet
Air outlet
Wrapping Tape
Wall Pipe
Front panel
Filter
MODE
(AUTO/COOL/DRY/FAN/HEAT).
setting.
: Press to decrease temperature
setting.
FAN
Press it set swing angle.
TIMER ON
TIMER OFF
CLOCK
TEMP
TURBO
SLEEP
LIGHT
Press it to set auto-on timer.
Press it to set auto-off timer
Press it set clock.
1
6
7
5
3
2
4
11
10
14
9
12
13
15
Operation of Remote Controller
3
9
10
13
12
5
4
11
8
7
2
1
6
8
Press it to turn on/off the light.
Press to start or stop operation.
: Press to increase temperature
Press to set fan speed.
Press to select operation mode
SENSOR
AIR SWEEP
EXTEND
AUTO
15
14
START / STOP
4
DIGITAL display:
This area will show the set tempe-
rature.
LOCK icon:
is displayed by pressing "+"
and-” buttons simultaneously. Press
them again to clear the display.
LIGHT icon:
is displayed by pressing the
LIGHT button. Press LIGHT button
again to clear the display.
22
MODE icon:
If MODE button is pressed,
current operation mode icon
(AUTO), ( COOL),
(DRY), (FAN) or (HEAT
only for heat pump models) will show.
18
is displayed when pressing
display.
After pressing TIMER button, ON or
OFF will blink.This area will show
the set time.
SET TIME display:
Pressing TEMP button,
(set temperature),
ambient temperature)
(outdoor ambient temperature)
and blank is displayed circularly.
(indoor
TEMP icon:
SLEEP icon :
is displayed by pressing
the SLEEP button. Press this
button again to clear the display.
19
is displayed when pressing the
nottub siht sserP.nottub OBRUT
again to clear the display.
TURBO icon:
Operation of Remote Controller
icon:
AIR SWEEP
16
17
21
20
23
24
16
1
7
18
19
20
21
22
23
24
the
button.
AIR SWEEP
Press this button again to clear the
27
26
25
5
is displayed when pressing the
again to clear the display.
Press FAN button to select the
desired fan speed setting (AUTO-
Low-Med-High).Your selection will
be displayed in the LCD windows,
except the AUTO fan speed.
FAN SPEED display:
is displayed when pressing the
to clear the display.
Operation of Remote Controller
icon:
SENSOR
icon:
EXTEND
EXTEND
button. Press this button
26
25
27
16
1
7
18
19
20
21
22
23
24
27
26
25
6
SENSOR
button. Press this button
again
Pressing CLOCK button,
blinks. Within 5 seconds , pressing + or - button adjusts the
CLOCK :
present time. Holding down either button above 2 seconds increases or decreases the
time by 1 minute every 0.5 second and then by 10 minutes every 0.5 second. During
blinking after setting, press CLOCK button again to confirm the setting, and then
will
be constantly displayed.
7
Remote Controller Description
:
This button is used for setting Fan Speed in the sequence that goes from AUTO,
to
then back to Auto.
,
,
,
FAN
:
6
MODE :
5
Each time you press this button, a mode is selected in a sequence that goes from AUTO,
COOL,DRY, FAN,and HEAT
*
,as the following:
AUTO
COOL
DRY
FAN HEAT
*
*Note: Only for models with heating
function.
After energization, AUTO mode is defaulted. In AUTO mode, the set temperature will not
be displayed on the LCD, and the unit will automatically select the suitable operation
mode in accordance with the room temperature to make indoor room comfortable.
1
3
2
4
Press this button to turn on the unit .Press this button again to turn off the unit.
Press this button to decrease set temperature. Hold it down for 2 seconds or more
to rapidly decrease set temperature. In AUTO mode, set temperature is not
adjustable.
Press this button to increase set temperature. Hold it down for 2 seconds or more
to rapidly increase
set temperature. In AUTO mode, set temperature is not
adjustable.
Auto
Low speed
Medium speed
High speed
Remote Control Instructions
SENSOR (SAVE)
:
Press this button to turn on SENSOR(SAVE) function. Saves room ambient temperature
and automatically adjusts maintaining that room ambient until pressed again which
cancels the SENSOR(SAVE) function.
START / STOP
:
AUTO
7
13
TEMP:
ambient temperature, 5s later or within 5s, it receives other remote control signal that will
return to display the setting temperature. if the users haven't set up the temperature
displaying status,that will display the setting temperature.(This function is not applicable
for some models).
TIMER ON :
TIMER OFF :
11
10
TURBO:
12
Press this button to initiate the auto-ON timer. To cancel the auto-timer program, simply
press this button again.
After pressing this button, disappears and "ON "blinks
. 0
0:00 is displayed for ON time
setting. Within 5 seconds, press + or - button to adjust the time value. Every press of either
button changes the time setting by 1 minute. Holding down either button rapidly changes the
time setting by 1 minute and then 10 minutes. Within 5 seconds after setting, press TIMER
ON button to confirm.
Press this button to set up & down swing angle, which circularly changes as below:
OFF
This remote controller is universal. If any command , or is sent out,
the unit will carry out the command as
indicates the guide louver swings as:
fan will continue operation for 10 min utes in order to dry the indoor unit even though you
have turned off the unit.
HEAT mode.
Press this button to activate / deactivate the Turbo function which enables the unit to
reach the preset temperature in the shortest time. In COOL mode, the unit will blow strong
cooling air at super high fan speed. In HEAT mode, the unit will blow strong heating air
at super high fan speed. (This function is not applicable for some models).
Press this butto
n to initiate the auto-off timer. To cancel the auto-timer program, simply
press the button again.TIMER OFF setting is the same as TIMER ON.
9
8
AIR SWEEP:
EXTEND(DRY):
Pressing button in COOL or DRY mode, the icon is displayed and the indoor
After energization,
OFF is defaulted. is not available in AUTO, FAN or
EXTEND
EXTEND
EXTEND
Remote Control Instructions
the indoor setting temperature or indoor ambient
By pressing this button you can display
temperature.When the indoor unit it will display the setting temperature,
is first powered on
if the temperature's display status is changed from other status to" ",displays the
8
1.Remove the battery cover plate from the rear of the remote controller.
(As shown in the figure)
2.Take out the old batteries.
3.Insert two new AAA1.5V dry batteries, and pay attention to the polarity
(+/-).
4. Reinstall the battery cover plate
Notes:
When replacing the batteries, do not use old or different types of
batteries, it may cause malfunction.
If the remote controller will not be used for a long time, please remove
batteries to prevent batteries from leaking.
Remote should be kept
3 feet
away from the TV set or stereos.
If the remote controller does not operate normally, remove batteries and
reinsert after 30
seconds. If abnormal operation continues, replace the
batteries.
Diagram for removal of
batteries
Replacement of Batteries
Press "+ " and "-" buttons simultaneously
to lock or unlock the keypad. If the remote
controller is locked, is pressing any button, blinks
three times.
SLEEP:
LIGHT:
16
Press this button to go into the SLEEP operation mode. Press it again to cancel this
Press LIGHT button to turn on the display's light and press this button again to turn off
disappears.
Combination of "+" and "-" buttons: About lock
14
15
or DRY mode to maintain the most
comfortable temperature for you.
Remote Control Instructions
17
Combination of "MODE" and "-" buttons:
, press "MODE"
displayed. In this case,
Allows you to toggle between Fahrenheit and Celsius.
When the unit is OFF
and " - " buttons simultaneously to switch between and .
9
the display's light. If the light is turned on, is displayed. If the light is tunrned off,
function. This function is available in COOL
If the wireless remote control is lost or
broken, please use the manual switch
button. At this time, the unit will run in the
Auto mode, the temperature and fan
speed cannot be changed. The
operation is shown below:
Emergency operation
Manual switch
Fig.3
Front Panel Illumination On/Off
Display indicator light control of indoor unit
To turn 'On'
the light function,the icon will display
on the remote control screen by pressing the "Light"
button. In which case,the display indicator light will be
on if the unit receives this signal.
To turn 'Off
'
the light function,the
will
disappear
on
the remote control screen by pressing
this button. In which case, the display indicator light
will be off if the unit receives this signal.
Display indicator light on:
Display indicator light off:
Turn off the unit:
Press manual switch to turn off unit.
(Fig .3) Open front panel and the manual switch
is on the rightside near electrical connection
cover.
Turn on the unit:
Press manual button and unit will run in
Auto mode immediately. The unit will adjust
to the indoor temperature previously
selected (Cooling or Fan) and obtain a
comfortable setting.
10
Clean the air filter
(a)
(b)
Caution
Turn power off and pull out the power plug before cleaning air conditioner, or it may cause electric
shock.
Never spray water directly into indoor or outdoor components while power is connected as
electrocution or shock can occur.
Volatile liquid (e.g. thinner or gasoline) will damage the air conditioner. (Wipe the unit with a dry
soft cloth, or a cloth slightly moistened with water or cleanser.)
Cleaning the front panel
Clean the air filter (Recommended once every three months)
Removing air filter
on both sides of the front panel are slots pull front
open, pull the air fil
ter
downward and take it out,
please see the Fig. 4(a, b).
To clean the dust adhering to the filters, you can either
use a vacuum cleaner, or wash them with warm water
and neutral detergent (the water should be below
113ºF degree) ,and allow to dry.
Reinsert the air filter
Reinsert the filters along the same location they had
been removed from and snap front panel back into
place.
Fig.4
When cleaning the front panel, please dip the cloth into water with temperature below 113ºF, then dry the
cloth and wipe the front panel or dirty portion of front.
Note: Do not immerse the front panel in water, there are PCB (electronic) components and circuit
diagrams on the front panel that may become damaged.
Routine Maintenance
If there is an excessive amount of dust around the air conditioner,
to moderate personal injury.
the air filter should
be cleaned more frequently. Once filters are removed
sharp.
Failure to do so can result in minor
do not touch fins, edges may be
NOTE: Never use water above 113ºF to clean, or it
can cause deformation or discoloration.
NOTE:
11
The sound of water flow
during operation.
Turn unit on.
Raise/Lower temperature
setting.
Unit will resume normal
operation once power
has been restored.
Clean air filter.
Clean air conditioner.
Please contact an
Authorized Friedrich
Service Agency
When the compressor
starts or stops running
you may here a swoosh
or gurgle, this isn't
a malfunction.
Cause
12
In COOL Mode there is a
mist emitted from the vent.
When the indoor temerature
and humidity are high and
there is a rapid cool down in
the room.
After running for a period of
time the indoor temperature
and humidity will decrease,
mist will fade away.
Unit does not cool/heat room
sufficiently.
The return/discharge air
grille is blocked.
Windows or doors to the
outside are open.
The setpoint is not set
to a cool/warm enough
setting.
The indoor filter is dirty or
obstructed
Outdoor coil is dirty or
obstructed.
Ambient temperature of the
space is to hot/cool.
The system was not properly
sized for the heat load
requirements of the space
Check that return/discharge
air are not blocked.
Check that windows and
doors are closed.
Adjust setpoint to a more
comfortable setting.
Please allow more time for
system to cool/heat living
space
Clean filter - (Refer to
routine maintenance
section for instruction)
Please contact your servicer
for more information if
previous options do not
remedy the issue.
Please contact servicer
to properly clean coils.
Cause
Immediately stop all operations and plug out, contact
the dealer if following situations occur.
There is harsh sound during operation.
There unusual and offending odors emitted during
operation.
Water is leaking in the room.
Breaker or Time delay fuse often trips.
Accidentally splashed water or other liquids into unit.
There is excessive or abnormal heat emanating from the power
cords.
Turn off unit and switch off breaker.
13
Wireless Remote control
does not work.
There is water leaking into
living space from indoor unit.
There is water leaking from
outdoor unit.
Noise from indoor unit.
Indoor unit not blowing air
Moisture on air vent
Not in frequency range
Remove batteries and reinstall.
High humidity
Unit is running in cool mode
Unit is running in Auto defrost
mode
Unit is running in Heat mode
Sound of fan
Unit is in Defrost mode.
Defrost of indoor coil
High Humidity
Condensation may have formed and
dripped off grille due to extended
cooling.
Humid conditions in living space.
Condensate drain overflow.
Drain pipe to indoor unit is loose.
Replace batteries.
Condensation may have formed on
piping.
Ice may have formed and is
defrosting into unit.
Condensation may have dripped off
outdoor coil.
Unit may have switched off for outdoor
coil to defrost in low ambient
conditions function will resume.
Sound can be blower or motor please
contact a service center if noise
persists.
Coil can become frosted in some
conditions and unit will cycle into a
defrost sound may be ice thawing
inside. Once defrost is complete
sound should not occur.
Service & Assistance
1
2
3
14
Before calling for service, please check the "Basic troubleshooting" section above. This
may help you to find the answer to your problem, avoid unnecessary service calls, and
save the cost of a service call if the problem is not due to the product itself. If you have
checked the "Basic troubleshooting" section and still need help, below you will find a list
of available services:
You can find the name of your local Authorized Service Provider by visiting our website
at www.friedrich.com.
If you require further assistance please call Friedrich
customer support at 1-800-541-6645.
Before calling please make sure that you have the full model and serial number, as well
as the date of purchase of you equipment available. Providing us with this information
will allow us to better assist you.
1.
2.
Condensate should drain easily from unit.
4.
Installation choice should be strong enough to handle the weight of the equipment and
insulate against vibration noise from operation.
5.
6.
7.
8.Follow installation requirements and dimensions.
1
.
Select a location with consideration of surroundings including pets and neighbors as heat
and cool will be discharged from equipment.
2
.
Select a location where there should be sufficient ventilation.
3
.
Select a location where there should be no obstructions cover the inlet and outlet.
4
.
The location should be able to withstand the full weight and vibration of the outdoor unit
and permit safe installation.
5
.
Select a dry place, but do not expose under the direct sunlight or strong wind.
6
.
3.
Keep system out of the reach of children and pets.
7.
8.
9.
Important Notices
Indoor Unit Placement
Air inlet and discharge should be kept free of obstruction at all times. Ensure airflow
through living space.
Be sure to leave enough space to allow access for routine maintenance. The height of the
installed location should be 8 ft or more from the floor.
Select a place
3 ft
or more away from TV or any other electric appliances.
Select a place where the filter can be easily taken out.
Do not use the unit in the immediate surroundings of a laundry, bath, shower
or swimming pool
9.
Installation
Outdoor Unit
Placement
Make sure that the outdoor unit installation dimension
are in accordance
with installation
dimension diagram, convenient for maintenance, repair.
The height difference of connecting the tubing within
32 ft
, the length of connecting the
tubing within
65 ft
.
Select a place where it is out of reach for the children.
Select a place where will not block the passage and do not influence the city appearance.
15
Note:
Follow wiring diagram to ensure that short circuit will not happen. Incorrect wiring can
cause potential for fire.
The breaker switch must have the functions of magnetic tripping and heat tripping, in
order to protect from short circuit.
Ensure that power circuit is dedicated and not shared with other equipment.
Power cable diameter should be followed.
2.
Do not damage power cord.
3.
4.
5.
Be sure to follow local and national electrical code.
Notices for installation
Safety Requirements For Electric Appliances
1.
Consideration should be made in location of outdoor unit as heat/cool is emitted, pets and
neighbors could be affected by this.
2. Select a location where there should be sufficient ventilation.
3.
Select a location where there should be no obstructions to cover the inlet and outlet.
4. The location should be able to withstand the full weight and vibration of the outdoor unit
and permit safe installation.
5. Select a dry place, but do not expose under the direct sunlight or strong wind.
6.
Outdoor Unit Installation Position Selection
Installation should follow instructions and dimensions.
16
1.
Keep system 5 feet from combustibles.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

Friedrich MRM09Y1J Mode d'emploi