Cal Spas Portable Spa Le manuel du propriétaire

Taper
Le manuel du propriétaire
LTR20111001, Rev. B
4/25/11
Important Safety Instructions
Basic Spa Information..................3
Preparing for Your New Portable Spa
Planning the Best Location..............5
Preparing a Good Foundation............5
230 Volt Electrical Installation...........6
RCD Wiring Diagram ...................8
6115 and 6215 Circuit Board Connection ..9
8015 Circuit Board Connection..........10
OE9905 Circuit Board Connection .......11
Filling and Powering Up Your Portable Spa 12
Operating Your Spa
6105 and 6205 Electronic Control Operation 1 3
8005 and 9005 Electronic Control Operation 1 6
Auxiliary Control Operation ............20
Wireless Spa Monitor .................20
Adjustable Jets ......................20
Diverter Knobs.......................21
Air Venturis .........................21
Adjustable Therapy System™ ...........21
Multi-Colored Spa Light Operation.......22
Waterfalls ..........................22
Water Quality Maintenance
Clear Water Plan .....................23
Before You Begin.....................23
Chemical Safety......................24
Chemical Descriptions.................25
Traditional Chemical Start Up...........26
Bromine Clear Water Plan..............26
Chlorine Clear Water Plan..............27
Ozonator Clear Water Plan .............27
Cal Clarity II Bromine Generator ........28
Maintenance Schedule ................30
Copyright 2011 Lloyd’s Material Supply, Inc. All rights reserved. Duplication without written
consent is strictly prohibited.
Cal Spas™, Adjustable Therapy System™, ATS™, Cal Premium™, Cal Select™, Cal Stone™,
Ultimate Fitness Spa Series™, and XL Heat Exchanger™ are registered trademarks.
Due to continuous improvement programs, all models, operation, and/or specications are
subject to change without prior notice.
LTR20111001, Rev. B
4/25/11
100-984
CONTACT INFORMATION
For customer service, please contact
your authorized dealer immediately. If
you need additional information and/
or assistance, please contact:
LMS Customer Service Department
1462 East Ninth Street
Pomona, CA 91766.
Phone: 1-909-623-8781
Fax: 1-909-629-3890
Cleaning and Maintenance
Removing and Reseating the Pillows.....31
Spa Cover...........................31
Draining Your Portable Spa ............32
Winterizing (Cold Climate Draining) .....33
Cleaning the Cover, Shell and Pillows ....33
Cleaning and Replacing the Filter........35
Using the Entertainment System
Operating the CD Player . . . . . . . . . . . . . . .36
Using the AQ-DM-2 iPod Docking Station .37
Appendix
Replacement Parts ...................38
Keeping Fit with your Cal Spa...........44
Limited Warranty.....................46
2011 Portable Spa
LTR20111001, Rev. B
Read This First!
www. ca l s p a s . c o m
3
When installing and using this electrical equipment,
always follow basic safety precautions. Following
these instructions will help make your rst spa session
a pleasurable one.
READ AND FOLLOW ALL INSTRUCTIONS
A licensed electrician may be required to upgrade your
standard receptacle and/or circuit breaker.
DANGER -- RISK OF ACCIDENTAL DROWNING:
Do not allow children to be in or around a spa unless
a responsible adult supervises them. Keep the spa
cover on and locked when not in use. See instructions
enclosed with your cover for locking procedures.
DANGER -- RISK OF INJURY: The suction ttings
in this spa are sized to match the specic water ow
created by the pump. Should the need arise to replace
the suction ttings, or the pump, be sure the ow
rates are compatible.
DANGER -- RISK OF INJURY: Never operate the
spa if the suction tting or lter baskets are broken
or missing.
DANGER -- RISK OF INJURY: Never replace a
suction tting with one that is rated less than the ow
rate marked on the original suction tting.
DANGER -- RISK OF ELECTRIC SHOCK: Install the
spa at least 1.5 meters from all metal surfaces. As an
alternative, a spa may be installed within 1.5 meters
of metal surfaces if each metal surface is permanently
bonded by a minimum #8 AWG solid copper conductor
to the outside of the spa’s control box.
DANGER -- RISK OF ELECTRIC SHOCK: Do not
permit any external electrical appliances, such as
lights, telephones, radios, televisions, and etc., within
1.5 meters of the spa. Never attempt to operate any
electrical device from inside the spa. This does not
apply to lights, stereos and televisions that are built in
to the spa as factory options from Cal Spas™.
WARNING – RISK OF INJURY
The spa water should never exceed 40˚C. Water
temperatures between 38˚C and 40˚C are considered
safe for a healthy adult. Lower water temperatures are
recommended for young children and when spa use
exceeds 10 minutes.
High water temperatures have a high potential for
causing fetal damage during pregnancy. Women who
are pregnant, or who think they are pregnant, should
always check with their physician prior to spa usage.
The use of alcohol, drugs or medication before or
during spa use may lead to unconsciousness, with
the possibility of drowning.
Persons suffering from obesity, a medical history of
heart disease, low or high blood pressure, circulatory
system problems or diabetes should consult a
physician before using the spa.
Persons using medications should consult a physician
before using the spa since some medications may
induce drowsiness while others may affect heart
rate, blood pressure and circulation.
Hyperthermia Danger
Prolonged exposure to hot air or water can induce
hyperthermia. Hyperthermia occurs when the
internal temperature of the body reaches a level 2˚C
to 4˚C above the normal body temperature of 37˚C.
While hyperthermia has many health benets, it is
important not to allow your body’s core temperature
to rise above 39.5˚C. Symptoms of excessive
hyperthermia include dizziness, lethargy, drowsiness
and fainting. The effects of excessive hyperthermia
may include:
Failure to perceive heat
Failure to recognize the need to exit spa or hot
tub
Unawareness of impending hazard
Fetal damage in pregnant women
Physical inability to exit the spa
Unconsciousness
WARNING: The use of alcohol, drugs, or medication
can greatly increase the risk of fatal hyperthermia.
Basic Spa Information
The following operating and maintenance instructions
are very important and must be followed carefully.
With the proper care and maintenance, your Cal
Spa will provide you with years of satisfaction and
performance.
Do not be afraid to push buttons or turn knobs to
learn about your new Cal Spa, as it is built with
quality materials and excellent craftsmanship.
Your new Cal Spa has been engineered with a high-
powered water pump that pushes water through
various therapy jets, which will relax even the
tightest muscles. In addition to the water pressure,
you can add air into the spa water with air venturi
Important Safety Instructions
2011 Portable Spa
LTR20111001, Rev. B
Read This First!
www. c a l s p a s. c o m
4
handles located seat-side that increase the intensity of
your massage.
The ltering of this spa is very important. It will
minimize cleaning time and the amount of chemicals
needed to keep your spa water balanced. The two daily
pre-programmed lter cycles of two hours in duration
can be increased to six hour cycles if the need arises.
This can be accomplished through the topside control
panel.
IMPORTANT: Keep the spa covered when not in
use!
Covered spas use less electricity while maintaining
a set temperature.
Covering your spa will protect your spa’s nish
from the sun’s ultraviolet rays.
You are required to keep the spa covered to
maintain warranty coverage.
Covering your spa helps prevent children from
drowning in the spa.
Your new Cal Spa comes equipped with an electric
heater. Following the directions listed below will ensure
the most efcient operation:
NOTE: This method is only for spa usage under two
hours a week.
Keep the spa’s operating temperature 3˚C below
the desired usage temperature when not in use.
One or two hours before use, set the temperature
to the desired temperature.
If the spa usage exceeds two hours a week, the
set temperature should remain at the desired
usage temperature.
The air venturis should be used sparingly. When
open, water temperature drops quite rapidly and
can also dissipate chemicals.
Allowing the water temperature to lower more than
6˚C below the desired usage temperature and
reheating it prior to usage will cause the heater to
operate longer than it normally would maintaining
the desired temperature. Doing this will increase your
operating cost and makes your heater work more than
necessary.
The lter needs to be cleaned or changed on a regular
basis. This process takes only a few minutes and
the result is increased water clarity and equipment
longevity.
Water level is very important to the operation of your
spa. If the water level is too low or too high, your spa
will not operate properly. The water level should be to
the middle of the skimmer area when the spa is not
being used.
We recommend that your spa water be changed every
4 to 6 months. You may nd the need to change your
spa water more frequently with heavy use. When
empty, your spa should be cleaned with a non-abrasive
cleaner and then rinsed thoroughly.
See the section “Cleaning and Maintaining Your Spa”
for instructions on draining your spa.
When lling your spa, always ll through the skimmer
lter canister. Use only regular tap water.
WARNING: DO NOT USE SOFT WATER.
2011 Portable Spa
LTR20111001, Rev. B
Preparing for Your New Portable Spa
www. c a l s p a s. c o m
5
Most cities and counties require permits for exterior construction and electrical circuits. In addition, some
communities have codes requiring residential barriers such as fencing and/or self-closing gates on property to
prevent unsupervised access to the property by children. Your dealer can provide information on which permits
may be required and how to obtain them prior to the delivery of your Cal Spa™.
Prevent dirt and contaminants from being tracked into
your spa by placing a foot mat at the spa’s entrance
where the bathers can clean their feet before entering
your spa. You may also consider keeping a small water-
lled basin nearby for bathers to rinse their feet before
enter your spa.
Allow For Service Access
Make sure the spa is positioned so that access to the
equipment compartment and all side panels will not
be blocked.
Many people choose to install a decorative structure
around their spa. If you are installing your spa with
any type of structure on the outside, such as a gazebo,
remember to allow access for service. It is always best
to design special installations so that the spa can still
be moved, or lifted off the ground.
Preparing a Good Foundation
Your spa needs a solid and level foundation. The area
that it sits on must be able to support the weight of the
spa and the occupants who use it. If the foundation
is inadequate, it may shift or settle after the spa is in
place, causing stress that could damage your spa shell
or nish.
Damage caused by inadequate or improper foundation
support is not covered by the warranty. It is the
responsibility of the spa owner to provide a proper
foundation for the spa. We strongly recommended
that you have a qualied, licensed contractor prepare
the foundation for your spa.
Place the spa on a level foundation (preferably a 10
cm concrete slab). If you are installing the spa indoors,
pay close attention to the ooring beneath it. Choose
ooring that will not be damaged or stained.
If you are installing your spa on an elevated wood
deck or other structure, consult a structural engineer
or a contractor to ensure the structure will support the
weight of 68 kg per square foot.
Your Cal Spas™ retailer can help you with your
foundation and more. Your retailer has a wealth of
information and experience about how to get the most
out of your spa and can provide you with a full line of
accessories that are designed to compliment your spa
and increase your enjoyment.
Planning the Best Location
Here are some of the things that you will need to
consider when determining where to place your new
spa.
Safety First
Do not place your spa within 3 meters of overhead
power lines.
Consider How You Will Use Your Spa
How you intend to use your spa will help you determine
where you should position it. For example, will you use
your spa for recreational or therapeutic purposes? If
your spa is mainly used for family recreation, be sure
to leave plenty of room around it for activity. If you will
use it for relaxation and therapy, you’ll probably want
to create a specic mood around it.
Plan for Your Environment
If you live in a region where it snows in the winter or
rains frequently, place the spa near a house entry. By
doing this, you will have a place to change clothes and
not be uncomfortable.
Consider Your Privacy
In a cold-weather climate, bare trees won’t provide
much privacy. Think of your spa’s surroundings during
all seasons to determine your best privacy options.
Consider the view of your neighbors as well when you
plan the location of your spa.
Provide A View With Your Spa
Think about the direction you will be facing when
sitting in your spa. Do you have a special landscaped
area in your yard that you nd enjoyable? Perhaps
there is an area that catches a soothing breeze during
the day or a lovely sunset in the evening.
Keep Your Spa Clean
In planning your spa’s location, consider a location
where the path to and from the house can be kept
clean and free of debris.
Preparing for Your New Portable Spa
2011 Portable Spa
LTR20111001, Rev. B
Preparing for Your New Portable Spa
www. c a l s p a s. c o m
6
230 Volt Electrical Installation
All 230V spas must be permanently connected
(hardwired) to the power supply. These instructions
describe the only acceptable electrical wiring
procedure. Spas wired in any other way will void your
warranty and may result in serious injury.
This is the only acceptable electrical wiring procedure.
Spas wired in any other way will void your warranty.
See the wiring diagram on page 8.
The electrical wiring of this spa must meet the
requirements of any applicable local, state, and federal
codes. The electrical circuit must be installed by an
electrical contractor and approved by a local building /
electrical inspector.
RCD and Wiring Requirements
The power supplied to the spa must be on a dedicated
RCD protected circuit with no other appliances or
lights sharing the power.
Use copper wire with THHN insulation. Do not use
aluminum wire.
Use the table below to determine your GFCI and wiring
requirements.
When wires larger than #6 AWG are required, install
a junction box near the spa and use #6 AWG wire
between the junction box and the spa.
Wire runs over 26 m must increase wire gauge to the
next lower number. For example: A normal 50 amp
RCD with four #8 AWG copper wires run over 26
m would require you to go to four #6 AWG copper
wires.
Testing the RCD Breaker
Test the RCD breaker prior to rst use and periodically
when the spa is powered. To test the RCD breaker
follow these instructions (spa should be operating):
Press the TEST button on the RCD. The RCD will 1.
trip and the spa will shut off.
Reset the RCD breaker by switching the breaker 2.
to the full OFF position, wait a moment, then turn
the breaker back on. The spa should have power
again.
Spa Model GFCI Required Wires Required
All 230V spas except Ultimate
Fitness
One 32 amp RCD or two 16 amp
RCDs
Three #10 AWG copper wires
Spas with the 6205 control
box
One 32 amp RCD or two 16 amp
RCDs
Four #10 AWG copper wires
Fitness 2400 spa with one 5.5
kW heater
One 32 amp RCD or two 16 amp
RCDs
Four #10 AWG copper wires
Fitness 2400 with 8.5 kW
heater (optional) and Fitness
2500 spa
Service 1: One 32 amp RCD or
two 16 amp RCDs
Service 2: One 32 amp RCD or
two 16 amp RCDs
Service 1: Three #10 AWG copper wires
Service 2: Two #10 AWG copper wires
Fitness 4700 spa Service 1 (swim side): One 32
amp RCD or two 16 amp RCDs
Service 2 (swim side): One 32
amp RCD or two 16 amp RCDs
Service 3 (spa side): One 32
amp RCD or two 16 amp RCDs
Service 1: Three #10 AWG copper wires
Service 2: Two #10 AWG copper wires
Service 3: Three #10 AWG copper wires
2011 Portable Spa
LTR20111001, Rev. B
Preparing for Your New Portable Spa
www. c a l s p a s. c o m
7
Electrical Installation for 8.5 kW Heater
This applies to Ultimate Fitness spas with the 8.5 kW heater
only.
Two electrical services are required to heat the swim side of
the Fitness Spa.
2011 Portable Spa
LTR20111001, Rev. B
Preparing for Your New Portable Spa
www. c a l s p a s. c o m
8








GREEN/
YELLOW
(Ground)
GREEN/
YELLOW
(Ground)







GREEN/
YELLOW
(Ground)
CIRCUIT BOARD
RCD Wiring Diagram
RCD Device
2011 Portable Spa
LTR20111001, Rev. B
Preparing for Your New Portable Spa
www. c a l s p a s. c o m
9
T
B
1
H
T
R
2
J
101
H
TR
1
G
N
J
50
T1
J1
J2
J10
J
57
J58
J58
J
71
1
0VA
C
10VAC
J46
J46
J
2
5
5
J
2
6
6
J
72
J
9
0
J28
8
J28
J
1
A
J
2A
J
3
2
2
J
52
J
5
1
J
F
6, T30A 480
V
AV
O
ZON
E
PUM
P
1
O
PT. BLWR
/
P
U
MP 2
C
IR
C
. P
U
M
P
K1
K3
K4
K
6
E
.
G
ND
J
47
G
N
G
N
G
N
J
29
J
2
3
G
N
J17/2
6
K
2
K9
J
2
0
G
N
W2
1
2
3
4
W1
B
alboa
B
ALBOA INSTRUMENTS, INC.
G
S500
Z
C
OPYRIGHT 2007
MADE IN U.S.A
.
P
/N 22015_
B
J
60
J44
J
1
8
1
1
1
1
1
1
1
J
7
J8
EX
T R
LY
TST
J6
SEN A
V
A
C
S
EN
B
J
2
2
J4
3
AUX
F
J
1
3
J
11
J1
2
J
1
9
F2
S
1
S
WIT
C
HBANK A
K8
K5
C
9
U
4
F3
A
250
V
F
7
F1
F
10
A
250
V
F
4
,
T0.2
A
250
V
Pb
b
P
P
F3
To an optional
fuse-protected
expansion board
DIP Switch A10 must be OFF.
Three Phase Service
GREEN/
YELLOW
(Ground)
BROWN (Hot)
BROWN (Hot)
BLUE (Neutral)
BROWN (Hot)
From RCD Box
GROUND TERMINAL BLOCK
(ATTACHED TO OUTSIDE
OF SYSTEM BOX)
O
N
SWITCHBANK
1
2
3 4
5 6
7
8 9
10
For 1 x 16 Amp Service:
DIP Switch A10 must be ON.
For 1 x 32 Amp Service:
Set DIP Switch A10 such that total system amperage
draw never exceeds rated service input.
Completely remove the white
wire from J26 and J32, or J25.
Completely remove the blue wire
from J28 and J59.
3 x 16 Amp
5 Wires (3 Lines + 1 Neutrals + 1 Protective Earth)
Protective Earth wire (Green / Yellow) must be
connected to system ground terminal as marked.
IMPORTANT: Service MUST include a neutral wire
with a line to neutral voltage of 230VAC.
If an expansion board is installed,
black wire must connect to J28
(Line 2) only.
J
1
J
2
J
1
0
J
71
1
0VA
C
10VAC
J46
J46
J
7
2
J
1
A
J
2A
O
PT. BLWR
/
P
U
MP 2
G
N
6
J
2
0
G
N
J
60
J44
J
1
8
1
1
1
1
1
1
1
J
7
J8
EX
T R
LY
T
ST
J
6
SEN A
VA
C
S
EN
B
J
2
2
J
43
AUX
F
J11
J
1
2
J
19
K8
K5
C
9
U4
F3A
2
50V
F
10
A
250
V
F3
J
52
T
B
1
H
T
R
2
J
101
00
H
TR
1
G
N
J
50
T1
J
57
J58
J58
J
2
5
5
J
2
6
6
J
9
0
J28
8
J28
J
3
2
2
J
51
J
F
6, T30
A
480
V
O
Z
O
N
E
PUM
P
1
C
IR
C
. P
U
M
P
K1
K3
K4
K
6
E
.
G
ND
J
47
G
N
G
N
G
N
J
2
9
J
2
3
J17/2
K2
K9
W2
1
2
3
4
W1
B
alboa
B
ALB
O
A IN
S
TRUMENT
S,
IN
C
.
GS
500
Z
CO
PYRI
G
HT 2007
MADE IN U.
S
.A
.
P
/N 22015_
B
F2
S1
S
WIT
C
HBANK
A
F
4
,
T0.2
A
250
V
Pb
b
P
P
DIP Switch A10 must be OFF.
Dual Service
GREEN/
YELLOW
(Ground)
BLUE (Neutral)
BROWN (Hot)
BLUE (Neutral)
BROWN (Hot)
From RCD Box
O
N
SWITCHBANK
1 2 3 4 5 6 7 8 9 10
GROUND TERMINAL BLOCK
(ATTACHED TO OUTSIDE
OF SYSTEM BOX)
2 x 16 Amp
5 Wires (2 Lines + 2 Neutrals + 1 Protective Earth)
Protective Earth wire (Green / Yellow) must be
connected to system ground terminal as marked.
Completely remove the white
wire from J26 and J32.
Note: J32 and J25 are
electrically identical. The white
wire may be attached to either
terminal before removal.
Single Service
GREEN/
YELLOW
(Ground)
BLUE (Neutral)
BROWN (Hot)
From RCD Box
O
N
SWITCHBANK
1 2 3 4 5 6 7 8 9 10
J
1
J
2
J
1
0
J
71
10VAC
10VAC
J46
J46
J
7
2
J
1
A
J
2A
O
PT. BLWR/PUMP 2
G
N
J
17
/
2
6
J
2
0
G
N
J
1
8
1
J
43
J
1
3
HBANK
K8
K5
C
9
U4
F3A
2
50V
F7
F1
F
10
A
250
V
F
3
T1
J
9
0
P
UMP
1
K1
K3
K4
K6
E
.
G
ND
G
N
J
2
3
K2
K
9
F2
S1
S
WIT
C
T
B
1
H
T
R
2
J
101
00
H
TR
1
G
N
J
5
0
J
57
J58
J58
J
2
5
5
J
2
6
6
J28
8
J28
J
3
2
2
J
52
J
51
J
F
6
,
T30
A
480
V
AV
O
Z
O
N
E
C
IR
C
. P
U
M
P
J
47
G
N
G
N
J
2
9
W2
1
2
3
4
W1
B
alboa
B
ALB
O
A IN
S
TRUMENT
S,
IN
C
.
GS
500
Z
CO
PYRI
G
HT 2007
MADE IN U.
S
.A
.
P/
N 22015_
B
F
4, T0.2A 250
V
Pb
b
P
P
J
60
J44
1
1
1
1
1
1
J
7
J8
EX
T R
LY
T
ST
J
6
SEN A
VA
C
S
EN
B
J
2
2
AUX
F
J11
J
1
2
J
19
GROUND TERMINAL BLOCK
(ATTACHED TO OUTSIDE
OF SYSTEM BOX)
is is the factory
default configuration.
1 x 16 Amp or 1 x 32 Amp
3 Wires (1 Line + 1 Neutral + 1 Protective Earth)
Protective Earth wire (Green / Yellow) must be
connected to system ground terminal as marked.
6115 and 6215 Circuit Board Connection
2011 Portable Spa
LTR20111001, Rev. B
Preparing for Your New Portable Spa
www. c a l s p a s. c o m
10
8015 Circuit Board Connection
DIP Switch A2 must be ON.
Three Phase Service
GREEN/
YELLOW
(Ground)
T
B
1
B
alboa
G
N
G
N
G
N
G
N
G
N
G
N
J68
J68
J101
J101
J100
J100
J
26
J53
J53
J99
J99
J97
J97
W
15
J27
J2
J2
J27
J32
J32
J
5
5
J9
0
J
1
T1
J
5
6
J
60
J
3
3
3
J41
J41
J45
J45
J
2
W1
F4
W
2
J
81
J30
J30
J
2
8
J
2
3
J
9
8
J54
J54
J54
J54
J
7
9
J9
5
J
94
J14
J14
J
5
7
J9
6
J
93
F6
F7
K7
K6
K8
F
US
E T30A 480
V
F
U
S
E F10A 250V
FUSE T30A 480
V
J
59
J
5
8
J5
K3
W4
K2
F5
J
3
J4
F2
F
US
E T0.2A
2
40V
K4
K11
K10
K9
K1
J
9
G
W3
BALBOA INSTRUMENTS, INC
.
GL2000 T
C
MA
C
H 3
P
/
N 22898 REV D
CO
PYRIGHT 2006
M
ADE IN U.S.A.
J
13
J
1
5
J7
J
82
J
22
J
24
EX
T RE
LAY
J6
EXT 2
S
P3
AU
X
F
A
L
ARM
S
EN A VA
C
S
EN
B
J
91
TS
T
S
WIT
C
HBANK
A
FUSE F3A 250
V
A
D
CM
MAIN
P
ANE
L
MAIN
P
ANE
L
MAIN
PAN
E
L
AUX
PAN
E
L
A
U
X
PAN
E
L
R
EM
O
T
E
J
6
9
J20
J
7
1
J
7
2
J
70J10J39
F1
H
TR
H
2
H
TR1
H
E
XT I
/O
J
36
J
8
3.0kW
From RCD Box
GROUND TERMINAL BLOCK
(ATTACHED TO OUTSIDE
OF SYSTEM BOX)
For 1 x 16 Amp Service:
DIP Switch A2 must be ON.
For 1 x 32 Amp Service:
DIP Switch A2 must be OFF.
Completely remove the white
wire from J26 and J32.
Completely remove the blue wire
from J28 and J57.
3 x 16 Amp
5 Wires (3 Lines + 1 Neutrals + 1 Protective Earth)
Protective Earth wire (Green / Yellow) must be
connected to system ground terminal as marked.
IMPORTANT: Service MUST include a neutral wire
with a line to neutral voltage of 230VAC.




O
N
SWITCHBANK
1 2 3 4 5 6 7 8 9 10 11 12
DIP Switch A2 must be ON.
Dual Service
GREEN/
YELLOW
(Ground)
T
B
1
B
alboa
G
N
G
N
G
N
G
N
G
N
G
N
J68
J68
J101
J101
J100
J100
J
26
J53
J53
J99
J99
J97
J97
W
15
J27
J2
J2
J27
J32
J32
J
5
5
J9
0
J
1
T1
J
5
6
J
60
J
3
3
3
J41
J41
J45
J45
J
2
W1
F4
W
2
J
81
J30
J30
J
2
8
J
2
3
J
9
8
J54
J54
J54
J54
J
7
9
J9
5
J
94
J14
J14
J
5
7
J9
6
J
93
F6
F7
K7
K6
K8
F
US
E T30A 480
V
F
U
S
E F10A 250V
FUSE T30A 480
V
J
59
J
5
8
J5
K3
W4
K2
F5
J
3
J4
F2
F
US
E T0.2A
2
40V
K4
K11
K10
K9
K1
J
9
G
W3
BALBOA INSTRUMENTS, INC
.
GL2000 T
C
MA
C
H 3
P
/
N 22898 REV D
CO
PYRIGHT 2006
M
ADE IN U.S.A.
J
13
J
1
5
J7
J
82
J
22
J
24
EX
T RE
LAY
J6
EXT 2
S
P3
AU
X
F
A
L
ARM
S
EN A VA
C
S
EN
B
J
91
TS
T
S
WIT
C
HBANK
A
FUSE F3A 250
V
A
D
CM
MAIN
P
ANE
L
MAIN
P
ANE
L
MAIN
PAN
E
L
AUX
PAN
E
L
A
U
X
PAN
E
L
R
EM
O
T
E
J
6
9
J20
J
7
1
J
7
2
J
70J10J39
F1
H
TR
H
2
H
TR1
H
E
XT I
/O
J
36
J
8
3.0kW
From RCD Box
GROUND TERMINAL BLOCK
(ATTACHED TO OUTSIDE
OF SYSTEM BOX)
2 x 16 Amp
5 Wires (2 Lines + 2 Neutrals + 1 Protective Earth)
Protective Earth wire (Green / Yellow) must be
connected to system ground terminal as marked.
Completely remove the white
wire from J26 and J32.
Note: J32 and J23 are
electrically identical. The white
wire may be attached to either
terminal before removal.




O
N
SWITCHBANK
1 2 3 4 5 6 7 8 9 10 11 12
Single Service
GREEN/
YELLOW
(Ground)
From RCD Box
O
N
SWITCHBANK
1 2 3 4 5 6 7 8 9 10 11 12
T
B
1
B
alboa
G
N
G
N
G
N
G
N
G
N
G
N
J68
J68
J101
J101
J100
J100
J
26
J53
J53
J99
J99
J97
J97
W
15
J27
J2
J2
J27
J32
J32
J
5
5
J9
0
J
1
T1
J
5
6
J
60
J
3
3
3
J41
J41
J45
J45
J
2
W1
F4
W
2
J
81
J30
J30
J
2
8
J
2
3
J
9
8
J54
J54
J54
J54
J
7
9
J9
5
J
94
J14
J14
J
5
7
J9
6
J
93
F6
F7
K7
K6
K8
F
US
E T30A 480
V
F
U
S
E F10A 250V
FUSE T30A 480
V
J
59
J
5
8
J5
K3
W4
K2
F5
J
3
J4
F2
F
US
E T0.2A
2
40V
K4
K11
K10
K9
K1
J
9
G
W3
BALBOA INSTRUMENTS, INC
.
GL2000 T
C
MA
C
H 3
P
/
N 22898 REV D
CO
PYRIGHT 2006
M
ADE IN U.S.A.
J
13
J
1
5
J7
J
82
J
22
J
24
EX
T RE
LAY
J6
EXT 2
S
P3
AU
X
F
A
L
ARM
S
EN A VA
C
S
EN
B
J
91
TS
T
S
WIT
C
HBANK
A
FUSE F3A 250
V
A
D
CM
MAIN
P
ANE
L
MAIN
P
ANE
L
MAIN
PAN
E
L
AUX
PAN
E
L
A
U
X
PAN
E
L
R
EM
O
T
E
J
6
9
J20
J
7
1
J
7
2
J
70J10J39
F1
H
TR
H
2
H
TR1
H
E
XT I
/O
J
36
J
8
3.0kW
GROUND TERMINAL BLOCK
(ATTACHED TO OUTSIDE
OF SYSTEM BOX)
is is the factory
default conguration.
1 x 16 Amp or 1 x 32 Amp
3 Wires (1 Line + 1 Neutral + 1 Protective Earth)
Protective Earth wire (Green / Yellow) must be
connected to system ground terminal as marked.


2011 Portable Spa
LTR20111001, Rev. B
Preparing for Your New Portable Spa
www. c a l s p a s. c o m
11
OE9905 Circuit Board Connection
DIP Switch A2, A3, and A4 must be ON.
DIP Switch A11 must be OFF.
Three Phase Service
GREEN/
YELLOW
(Ground)
BROWN (Hot)
BROWN (Hot)
BLUE (Neutral)
BROWN (Hot)
From RCD Box
GROUND TERMINAL BLOCK
(ATTACHED TO OUTSIDE
OF SYSTEM BOX)
Completely remove the white
wire from J26 and J32.
Note: J32 and J23 are
electrically identical. The white
wire may be attached to either
terminal before removal.
Completely remove the blue wire
from J28 and J57.
Note: J57, J58 and J59 are
electrically identical. The blue
wire may be attached to either
terminal before removal.
Move the brown wire from J23 or
J32 to J28.
3 x 16 Amp
5 Wires (3 Lines + 1 Neutrals + 1 Protective Earth)
Protective Earth wire (Green / Yellow) must be
connected to system ground terminal as marked.
IMPORTANT: Service MUST include a neutral wire
with a line to neutral voltage of 230VAC.
T
B
1
B
alboa
G
N
G
N
G
N
G
N
G
N
G
N
J68
J68
J101
J101
J100
J
2
6
J53
J53
J99
J99
J97
J97
W
1
5
J27
J2
J2
J27
J32
J32
J5
5
J
9
0
J1
T1
J56
J
60
J
3
3
3
J41
J41
J45
J45
J2
W1
F4
W2
J
8
1
J31
J31
J
12
J30
J30
J
28
J
2
3
J98
J54
J54
J54
J54
J
79
J
95
J
94
J14
J14
J
5
7
J
9
6
J
9
3
F6
F
7
K7
K6
K
8
FU
S
E T30A 480V
F
US
E F10A 250V
F
U
S
E T30A 480V
J
5
9
J
5
8
J
5
K3
W
4
K2
F5
J3
J
4
F
2
F
US
E T0.3A
240
V
K4
K11
K10
K9
K1
J
9
NG
W3
J
1
3
J
1
5
J
17
J
82
J
2
2
J
24
EXT RELAY
J
6
EXT 2S P3
AUX F
ALA
R
M
S
EN
A
VA
C
S
EN
B
J8
3
J
9
1
C
F
G
J
17
T
S
T
S
WIT
C
HBANK A
S
WIT
C
HBANK B
F
USE F3A 250V
ADC
M
MAIN
PAN
E
L
M
AI
N
PANEL
MAIN
P
AN
E
L
AU
X
P
AN
E
L
A
UX
PAN
EL
R
EMOTE
J69
J
20
J71 J72
J70J1
0
J
39
F1
H
T
R
H
2
HTR1
H
EXT I
/O
J36
J
8
Ozone
Conguration
Settings
Enabled
RTC
Enabled
A.V.
Spa
Light
Blower
2-Spd P1
3.0 kW
3.0kW
Heater rated @ 230V
J8 must be Jumpered
O
N
1
2
3 4
5
6
7
8 9
10
11
12
Dual Service
GREEN/
YELLOW
(Ground)
BLUE (Neutral)
BROWN (Hot)
BLUE (Neutral)
BROWN (Hot)
T
B
1
B
alboa
G
N
G
N
G
N
G
N
G
N
G
N
J68
J68
J101
J101
J100
J
2
6
J53
J53
J99
J99
J97
J97
W
1
5
J27
J2
J2
J27
J32
J32
J5
5
J
9
0
J1
T1
J56
J
60
J
3
3
3
J41
J41
J45
J45
J2
W1
F4
W2
J
8
1
J31
J31
J
12
J30
J30
J
28
J
2
3
J98
J54
J54
J54
J54
J
79
J
95
J
94
J14
J14
J
5
7
J
9
6
J
9
3
F6
F
7
K7
K6
K
8
FU
S
E T30A 480V
F
US
E F10A 250V
F
U
S
E T30A 480V
J
5
9
J
5
8
J
5
K3
W
4
K2
F5
J3
J
4
F
2
F
US
E T0.3A
240
V
K4
K11
K10
K9
K1
J
9
NG
W3
J
1
3
J
1
5
J
17
J
82
J
2
2
J
24
EXT RELAY
J
6
EXT 2S P3
AUX F
ALA
R
M
S
EN
A
VA
C
S
EN
B
J8
3
J
9
1
C
F
G
J
17
T
S
T
S
WIT
C
HBANK A
S
WIT
C
HBANK B
F
USE F3A 250V
ADC
M
MAIN
PAN
E
L
M
AI
N
PANEL
MAIN
P
AN
E
L
AU
X
P
AN
E
L
A
UX
PAN
EL
R
EMOTE
J69
J
20
J71 J72
J70J1
0
J
39
F1
H
T
R
H
2
HTR1
H
EXT I
/O
J36
J
8
Ozone
Conguration
Settings
Enabled
RTC
Enabled
A.V.
Spa
Light
Blower
2-Spd P1
3.0 kW
3.0kW
Heater rated @ 230V
J8 must be Jumpered
From RCD Box
GROUND TERMINAL BLOCK
(ATTACHED TO OUTSIDE
OF SYSTEM BOX)
2 x 16 Amp
5 Wires (2 Lines + 2 Neutrals + 1 Protective Earth)
Protective Earth wire (Green / Yellow) must be
connected to system ground terminal as marked.
Completely remove the white
wire from J26 and J32.
Note: J32 and J23 are
electrically identical. The white
wire may be attached to either
terminal before removal.
DIP Switch A2, A3, and A4 must be ON.
DIP Switch A11 must be ON if using Special
Amperage Rule.
DIP Switch A11 must be OFF if not using
Special Amperage Rule.
O
N
1
2
3 4
5
6 7 8 9 10 11 12
Single Service
GREEN/
YELLOW
(Ground)
BLUE (Neutral)
BROWN (Hot)
T
B
1
B
alboa
G
N
G
N
G
N
G
N
G
N
G
N
J68
J68
J101
J101
J100
J
2
6
J53
J53
J99
J99
J97
J97
W
1
5
J27
J2
J2
J27
J32
J32
J5
5
J
9
0
J1
T1
J56
J
60
J
3
3
3
J41
J41
J45
J45
J2
W1
F4
W2
J
8
1
J31
J31
J
12
J30
J30
J
28
J
2
3
J98
J54
J54
J54
J54
J
79
J
95
J
94
J14
J14
J
5
7
J
9
6
J
9
3
F6
F
7
K7
K6
K
8
FU
S
E T30A 480V
F
US
E F10A 250V
F
U
S
E T30A 480V
J
5
9
J
5
8
J
5
K3
W
4
K2
F5
J3
J
4
F
2
F
US
E T0.3A
240
V
K4
K11
K10
K9
K1
J
9
NG
W3
J
1
3
J
1
5
J
17
J
82
J
2
2
J
24
EXT RELAY
J
6
EXT 2S P3
AUX F
ALA
R
M
S
EN
A
VA
C
S
EN
B
J8
3
J
9
1
C
F
G
J
17
T
S
T
S
WIT
C
HBANK A
S
WIT
C
HBANK B
F
USE F3A 250V
ADC
M
MAIN
PAN
E
L
M
AI
N
PANEL
MAIN
P
AN
E
L
AU
X
P
AN
E
L
A
UX
PAN
EL
R
EMOTE
J69
J
20
J71 J72
J70J1
0
J
39
F1
H
T
R
H
2
HTR1
H
EXT I
/O
J36
J
8
Ozone
Conguration
Settings
Enabled
RTC
Enabled
A.V.
Spa
Light
Blower
2-Spd P1
3.0 kW
3.0kW
Heater rated @ 230V
J8 must be Jumpered
From RCD Box
GROUND TERMINAL BLOCK
(ATTACHED TO OUTSIDE
OF SYSTEM BOX)
is is the factory
default conguration.
1 x 16 Amp or 1 x 32 Amp
3 Wires (1 Line + 1 Neutral + 1 Protective Earth)
Protective Earth wire (Green / Yellow) must be
connected to system ground terminal as marked.
For both 1 x 16 Amp and 1 x 32 Amp Service:
DIP Switch A11 must be ON if using Special
Amperage Rule.
DIP Switch A11 must be OFF if not using
Special Amperage Rule.
For 1 x 16 Amp Service:
DIP Switch A2, A3, and A4
must be OFF.
For 1 x 32 Amp Service:
DIP Switch A2, A3, and A4
can be ON.
O
N
1
2
3 4
5
6 7 8 9 10 11 12
O
N
1
2
3 4
5
6 7 8 9 10 11 12
F1
2011 Portable Spa
LTR20111001, Rev. B
Preparing for Your New Portable Spa
www. c a l s p a s. c o m
12
Filling and Powering Up Your Portable Spa
Open the air relief valve (located next to the two 6.
lters, if equipped) after the air bubbles stop
coming out of it. Close the valve hand-tight.
Once the water is at the correct level and air is 7.
bled, turn on the power at the RCD breaker.
NOTE: When the power is turned on to the spa, it
will perform a diagnostic check for approximately ve
minutes. When the diagnostic is complete, the spa
will automatically operate at lter speed and continue
heating until the spa water temperature reaches the
default temperature of 37.5˚C.
If no water is owing when the pump is running 8.
there could be an air pocket at the suction side of
the pump. Shut off power to the spa and loosen
the pump union on the suction side of the pump
to bleed the air. When air is bled, turn power
back on.
Re-install the lter and the lter basket into the 9.
skimmer/lter canister.
The spa is now ready for use.
NOTE: Never run the spa with the gate valves closed
or without water circulating for long periods of time.
Be careful not to over-tighten the plumbing ttings.
Never ll your spa with soft water. Soft water makes it
impossible to maintain the proper water chemistry and
may cause the water to foam, which will ultimately
harm the nish of the spa and void your warranty.
Once the spa has been placed on an approved 1.
surface and has been correctly wired by a licensed
electrician, inspect all plumbing connections in the
equipment area of your spa. Ensure that these
connections are secure and that they did not
loosen during shipment.
If equipped, open all gate valves in the equipment 2.
area. Before operating the spa, these valves must
be in the UP or OPEN position.
Remove the lter basket and cartridge from 3.
skimmer/lter canister.
Place a garden hose in the skimmer/lter canister 4.
and ll your spa with regular tap water to the
proper water level (halfway up the skimmer
area).
(For owners of the automatic bromine generator) 5.
Make sure the dial on the face of the bromine
generator unit is turned to the OFF position.
2011 Portable Spa
LTR20111001, Rev. B
Operating Your Spa
www. c a l s p a s. c o m
13
Initial Start up
When rst powered up, it will automatically revert to
Priming mode. A Pr on the topside display will indicate
this. Priming mode will be active for less than ve
minutes at which time the heater will be activated and
the water temperature will be maintained in Standard
mode. The spa will heat to 37.5°C at start up until the
set temperature is changed as described below.
Temperature Adjustment
(Range 26°C to 40°C)
The electronic control panels display the
actual water temperature in degrees Celsius.
The displayed temperature will only be
current after the pump has been running for
at least 2 minutes.
To display the temperature that the spa is
set to:
Press the Temp button. The temperature
setting will ash.
While the display is ashing, each time you
press Temp button, the set temperature
will change up or down one degree.
If the desired temperature is opposite
of the direction each press of the button
is making, release button, allow display
to stop ashing and then press Temp
button to change temperature the other
direction.
Standard, Economy and Sleep
Heating Modes
Your new spa is equipped with a heating feature that
gives you complete control of the heating system.
When the spa is powered up, it will automatically start
in standard heating mode.
St will light briey on the main display. In this mode,
the heating system will automatically maintain
the set spa temperature. In the economy-heating
mode, the heating system will only activate during
ltration times.
Ec will display solid if temperature is not current
and will alternate with spa temperature if measured
temperature is current.
Economy mode will heat the water to the set
temperature while Sleep mode, indicated by a
SL on the main display, will also only activate the
6105 and 6205 Electronic Control Operation
Operating Your Spa
heater during the ltering cycles but will only heat
the water to within 10°C of the set temperature.
Like Economy mode, SL will display solid when
temperature is not current and will alternate with
actual temperature when it is current.
NOTE: Displayed temperature will only be current after
the pump has been running for at least two minutes.
Switching Modes
Press Temp button followed by the Light button.
Press the same sequence to switch to the next
mode.
2011 Portable Spa
LTR20111001, Rev. B
Operating Your Spa
www. c a l s p a s. c o m
14
Jets
Press the Jets button:
Once to activate low speed pump.
Twice to activate high speed.
Three times to return to turn pump off.
Light
Press the Light button to turn on the light. Press it
once again to turn the light off. All optional lighting
such as the control panel light and cabinet perimeter
lighting is controlled by the Light button and will turn
on and off with the spa light.
Option
Press the Option button to turn on the pump 2 on.
Press it once again to turn off the pump 2 off.
Automatic Time outs
These features will automatically turn themselves off
during periods of continuous use:
Low speed pump After 4 hours
High speed pumps After 15 minutes
Optional circulation pump After 15 minutes
Optional turbo After 15 minutes
Spa light After 15 minutes
Setting Filtration Cycles
Your spa is programmed to lter twice a day. The rst
cycle will begin 6 minutes after the spa is turned on
and the second cycle 12 hours later. The factory has
programmed the cycle to last for 2 hours but this can
be switched to 4, 6, or 8 hours depending on your
requirements. To set ltration time, turn off the power
to the spa at the time of day you would like one of the
ltration cycles to begin then turn back on after 30
seconds. When power has been restored, press the
“Temp” button then the “Jets” button. Press “Temp”
button again to change the ltering cycle duration.
When desired duration is selected press the “Jets”
button to exit.
At the beginning of each ltering cycle the Turbo system
will run for approximately 30 seconds. The low speed
pump will run for the duration of the ltering cycle
and if an Ozone system is installed it will be activated.
During ltering, “FC” will appear on the main display.
2011 Portable Spa
LTR20111001, Rev. B
Operating Your Spa
www. c a l s p a s. c o m
15
Diagnostic Messages
Message Meaning
-- Spa temperature is unknown. After pump has been running for 2 minutes temperature will
be displayed.
HH Overheat protection (spa is shutdown) DO NOT ENTER THE WATER! One sensor has detected
118˚F (48˚C) at the heater. Remove the spa cover and allow spa to cool below 107˚F (42˚C).
Press any button on the topside display to reset spa. If spa will not reset after spa has cooled,
turn off power for approximately 30 seconds and then turn power back on. If display message
is repeated then shut the power off to the spa and call your dealer or service organization.
OH Overheat protection (spa is shutdown) DO NOT ENTER THE WATER! If the spa has reached
110˚F (43˚C), remove the spa cover to cool the water. At 107˚F (42˚C), the spa should reset
itself. If the spa does not reset, then shut the power off to the spa, wait 30 seconds and
restore power to spa. If display message is repeated then shut the power off to the spa and
call your dealer or service organization.
IC A possible ice condition exists within the spa. No action is required, the pump will automatically
activate.
SA or Sb Spa is shut down. Spa has detected that one of the sensors is not operating properly. One
of these may display briey during overheat then disappear when overheat situation has been
resolved. Call your dealer or service organization if message does not go away.
Sn Sensor (Spa is shut down). The high limit or water temperature sensors are not working
correctly. Call your dealer or service organization.
HL A difference in readings between temperature sensors has been detected indicating a possible
water ow problem. Make sure spa is lled to proper level and that pumps are primed (water
is owing). Also check to make sure lter cartridges are clean. If message does not reset, call
your dealer or service organization.
LF This will display on the 5th occurrence of the “HL” message in 24 hours indicating a persistent
ow problem. The heater will be shut down but other functions will continue to operate.
Follow “HL” message actions then press any button to reset.
dr Insufcient water ow through the heater has been detected. Spa will be shut down for
15 minutes. Check water level and ll spa if water level is low. Make sure pumps are
primed (water is owing) and lter cartridges are clean. Press any button to reset or wait 15
minutes and spa will automatically reset. If message does not reset, call your dealer or service
organization.
dY Insufcient water level detected in heater. This will display on the 3rd occurrence of “dr
message. Follow directions for “dr” message and press any button to reset spa. Spa will not
automatically reset when “dY” is displayed.
Sf Safety Suction System (Spa is shut down). The display will show “Sf” as soon as the vacuum
switch closes. All functions will turn off and the system will be disabled until a panel button is
pressed.
ST Indicates heater is in standard mode
Ec Indicates heater is in economy mode
SL Indicates heater is in sleep mode
2011 Portable Spa
LTR20111001, Rev. B
Operating Your Spa
www. c a l s p a s. c o m
16
When rst powered up, the electronic system will
perform a self-diagnostic check and then it will
automatically heat to and maintain a temperature of
37.5˚C until you change the set temperature as listed
in the “Temperature Adjustment” section below.
These instructions will describe features and options
that your particular spa may not be equipped with.
Initial Start-up
When your spa is rst powered up, it displays some
conguration codes and then goes into priming mode
(Pr will appear on the display panel). This mode lasts
up to four minutes and then the spa begins to heat to
its pre -programmed temperature of 37.5˚C. You can
exit the priming mode early by pressing UP or DOWN
buttons.
Temperature Adjustment (26.0˚C -
40.0˚C)
The start-up temperature is set at 37.5˚C. The last
measured temperature is constantly displayed on
the control panel. Note that the last measured spa
temperature is displayed. The displayed temperature
will be updated when the pump has been running for
at least two minutes.
Press the UP or DOWN buttons once to display the
set temperature. Each time either button is pressed
again, the set temperature will increase or decrease
depending on which button is pressed. After three
seconds, the control panel will automatically display
the last measured spa temperature.
8005 and 9005 Electronic Control Operation
Time
When time hasn’t been programmed, the TIME icon
ashes. To set the time, press the TIME button and
then the MODE/PROG button. Use the UP and DOWN
buttons to adjust time. See the next page for more
detailed instructions.
Auxiliary controls
2011 Portable Spa
LTR20111001, Rev. B
Operating Your Spa
www. c a l s p a s. c o m
17
Standard, Economy, Sleep, and
Standby Modes
Mode/Prog: This button is used to switch between
standard, economy, and sleep modes.
Press MODE/PROG to enter mode programming.1.
Press the DOWN button to cycle through to the 2.
desired mode.
Press MODE/PROG to conrm selection.3.
Standard Mode: This is programmed to maintain
the desired temperature. Note that the last measured
spa temperature displayed is current only when the
pump has been running for at least two minutes. The
“STAND” icon will display until the mode is changed.
Economy Mode: Economy mode heats the spa to the
set temperature only during lter cycles. The “ECON”
icon will display until the mode is changed. Pressing
the JETS 1 button while in economy mode puts the
spa in standard-in-economy mode, which operates the
same as standard mode but reverts back to economy
mode automatically after one hour. During this
time, pressing the MODE/PROG button will revert to
economy mode immediately.
Sleep Mode: Sleep mode heats the spa to within 11˚C
of the set temperature only during lter cycles. The
“SLEEP” icon will display until the mode is changed.
Standby Mode: Pressing “Warm” or “Cool” then
“Jets 2” will turn off all spa functions temporarily. This
is helpful when changing a lter. Pressing any button
resets the spa.
Jets 1 and Jets 2
Press the JETS 1 button once to turn pump 1 on or off
and to shift between low and high speeds if equipped.
If left running, the low speed turns off after two hours
and the high speed turns off after 15 minutes. On
non-circulation systems, the low speed of pump 1
runs when the blower or any other pump is on. It may
also activate for at least two minutes every 30 minutes
to detect the spa temperature and then to heat to
the set temperature if needed, depending upon the
mode. When the low speed turns on automatically, it
cannot be deactivated from the panel; however, the
high speed may be started.
Option (Optional Blower)
Press the OPTION button to turn the optional
equipment on and off. If left on, the equipment will
automatically turn off after 15 minutes.
Light
Press the LIGHT button to turn the spa light on and
off.
Invert
Press the INVERT button to change the numbers in the
display to read upside down. Another press returns
the display to the right-side-up position. This enables
you to read the display while you are in the spa.
Locking the Panel
To lock the panel:
Press TIME, JETS 1, and the UP button within three
seconds. When locked, the panel will display “LOCK”.
All buttons are frozen except the TIME button.
To unlock the panel:
Press TIME, JETS ,1 then the DOWN button within
three seconds.
Setting the Temperature Lock
To activate the temperature lock:
Press the UP or DOWN button, TIME, JETS 1, then the
UP button within three seconds. The panel will display
“TEMP LOCK” when the set temperature is locked.
To unlock the set temperature:
Press the UP or DOWN button, TIME, JETS 1, then the
DOWN button..
Circulation Pump (optional)
If your system is equipped with a circulation pump,
it may be congured to work in one of two different
ways:
The circulation pump operates continuously (24 1.
hours) with the exception of turning off for 30
minutes at a time when the water temperature
reaches 1.7˚C above the set temperature (most
likely to happen in very hot climates).
The circulation pump will come on when the 2.
system is checking temperature, during lter
cycles, during freeze conditions, or when another
pump is on.
Preset Filter Cycles
There are two lter cycles per day. The start and end
times of each cycle are programmable. To program, set
the time as instructed above, then press MODE/PROG
to advance to the next setting (or to exit after the last
setting). The default lter cycles are as follows:
2011 Portable Spa
LTR20111001, Rev. B
Operating Your Spa
www. c a l s p a s. c o m
18
The rst lter cycle is automatically activated at
8:00 AM and operates the pump until 10:00 AM.
The “FILTER 1” indicator icon will light when lter
1 is running.
The second lter cycle is automatically activated
at 8:00 PM and operates the pump until 10:00 PM.
The “FILTER 2” indicator icon will light when lter
2 is running.
The pump and the ozone generator will run during
ltration. At the start of each lter cycle, the blower
will run on highest speed for 30 seconds to clean out
the air channels. The lowest speed of pump 2 and
pump 3 will run for ve minutes. In the event of power
loss or shut down, the time of day will need to be
reset for lter cycles to run according to your desired
programming.
Clean-up Cycle
When the pump or blower is turned on by a button
press, a clean-up cycle begins 30 minutes after the
pump or blower is turned off or times out. The pump
and the ozone generator will run for one hour.
Ozone (optional)
On most systems, the ozone generator (if installed)
runs during lter cycles (except when pump 1 is
operating at high speed on a non-circulation system)
and during clean-up cycles. On some systems, the
ozone generator operates whenever the pump runs.
If your system is congured with the optional ozone
disable feature, the ozone generator will turn off for
one hour any time a function button (JETS 1, JETS 2,
OPTION etc.) is pressed.
Freeze Protection
If the temperature sensors detect a drop to 6.7˚C
within the heater, the pump automatically activates
to provide freeze protection. The equipment stays
on until four minutes after the sensors detect that
the spa temperature has risen to 7.2˚C or higher. In
colder climates, an optional additional freeze sensor
may be added to protect against freeze conditions that
may not be sensed by the standard sensors. Auxiliary
freeze sensor protection acts similarly except with the
temperature thresholds determined by the switch and
without a four minute delay in turnoff.
Periodic Reminder Messages
Press the “Mode” button to reset a displayed reminder)
Message Frequency Action Required
rPH Every 7 days Test and adjust chemical levels per manufacturer’s instructions.
rSA Every 7 days Test and adjust chemical levels per manufacturer’s instructions.
rCL Every 30 days Remove, clean, and reinstall lter per manufacturer’s instructions.
rtg Every 30 days Test & reset GFCI per manufacturer’s instructions. Drain and rell spa per
manufacturer’s instructions.
rdr Every 90 days Drain and rell spa per manufacturer’s instructions.
RCO Every 180 days Clean and condition spa cover
RCH Every 365 days Install New Bio-Clean™ Filter
Diagnostic Messages
Message Meaning Action Required
No message on display. Power has been
cut off to the spa.
The control panel will be disabled until power
returns.
OHH “Overheat” - The spa has shut down.
One of the sensors has detected 47.7˚C
at the heater.
DO NOT ENTER THE WATER. Remove the spa cover
and allow water to cool. Once the heater has cooled,
reset by pushing any button. If spa does not reset,
shut off the power to the spa and call your dealer or
service organization.
2011 Portable Spa
LTR20111001, Rev. B
Operating Your Spa
www. c a l s p a s. c o m
19
OHS “Overheat” - The spa has shut down.
One of the sensors has detected that
the spa water is 43.3˚C.
DO NOT ENTER THE WATER. Remove the spa cover
and allow water to cool. At 41.6˚C, the spa should
automatically reset. If spa does not reset, shut off
the power to the spa and call your dealer or service
organization.
ICE “Ice” - Potential freeze condition
detected.
No action required. The pumps and the blower will
automatically activate regardless of spa status.
Sna Spa is shut down. The sensor that is
plugged into the Sensor Ajack is not
working.
If the problem persists, contact your dealer or service
organization. (May appear temporarily in an overheat
situation and disappear when the heater cools.)
Snb Spa is shut down. The sensor that is
plugged into the Sensor “B” jack is not
working.
If the problem persists, contact your dealer or service
organization. (May appear temporarily in an overheat
situation and disappear when the heater cools.)
Sns Sensors are out of balance. If this is
Alternating with the temperature, it
may just be a temporary Condition. If
the display shows only this message
(periodically blinking), the spa is shut
down.
If the problem persists, contact your dealer or service
organization.
HFL A substantial difference between the
temperature sensors was detected. This
could indicate a ow problem.
If the water level is okay, make sure the pumps have
been primed. If problem persists, contact your dealer
or service organization.
LF Persistent low ow problems. (Displays
on the fth occurrence of the “HFL
message within 24 hours.) Heater is shut
down, but other spa functions continue
to run normally.
Follow action required for “HFLmessage. Heating
capacity of the spa will not reset automatically; you
may press any button to reset.
dr Inadequate water detected in heater. Check water level in spa. Rell if necessary. If the
water level is okay, make sure the pumps have been
primed. Press any button to reset.
dry Inadequate water detected in heater.
(Displays on third occurrence of “dr”
message.) Spa is shut down.
Follow action required for “dr” message. Spa will not
automatically reset; you may press any button to
reset.
Pr When your spa is rst actuated, it will
go into Priming mode.
The Priming mode will last for up to four minutes
and then the spa will begin to heat and maintain the
water temperature in the Standard mode.
--For C Temperature unknown After the pump has been running for two minutes,
the temperature will be displayed.
- - - - - - Temperature not current in Economy or
Sleep mode.
In Economy or Sleep mode, the pump may be off for
hours outside a lter. If you wish to see the current
spa temperature, either switch to Standard mode or
turn Jets1 on for at least two minutes.
BUF Internal problem detected. Repair required. Contact your dealer or service
organization.
Stby Standby Mode has been activated by
pressing a button combination on the
user panel.
Press any button to leave Standby Mode and return
to normal operation.
SF Safety Suction. Spa is shut down. The display will show “SF” when a
vacuum switch closes. All functions will turn off and
the system will be disabled until a panel button is
pressed.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288
  • Page 289 289
  • Page 290 290
  • Page 291 291
  • Page 292 292
  • Page 293 293
  • Page 294 294
  • Page 295 295
  • Page 296 296
  • Page 297 297
  • Page 298 298
  • Page 299 299
  • Page 300 300
  • Page 301 301
  • Page 302 302

Cal Spas Portable Spa Le manuel du propriétaire

Taper
Le manuel du propriétaire