Titan Advantage™ EXP2455 Le manuel du propriétaire

Catégorie
Pulvérisateur de peinture
Taper
Le manuel du propriétaire

Ce manuel convient également à

1208 © SprayTECH. All Rights Reserved. Form No. 0552803A
Model Numbers:
0552066 Upright Cart Complete
0552067 Low Boy Cart Complete
SprayTECH
1770 Fernbrook Lane
Minneapolis, MN 55447
Technical Assistance/
Order Entry:
Fax - Technical Assistance:
Fax - Order Entry:
1-800-526-5362
1-800-525-9501
1-800-528-4826
www.spraytechinc.com
NOTE: This manual contains important warnings and
instructions. Please read and retain for reference.
EPX2455
Advantage Series
Piston Pump
Owner’s Manual
Do not use this equipment
before reading this manual!
2 © SprayTECH. All rights reserved.
Important Safety Information · Read all safety information before
operating the equipment. SAVE THESE INSTRUCTIONS.
This symbol indicates a hazardous situation,
which, if not not avoided could result in death or
serious injury.
To reduce the risks of fire or explosion, electrical
shock and the injury to persons, read and
understand all instructions included in this manual.
Be familiar with the controls and proper usage of
the equipment.
HAZARD: INJECTION INJURY
A high pressure paint stream produced by this
equipment can pierce the skin and underlying
tissues, leading to serious injury and possible
amputation. See a physician immediately.
DO NOT TREAT AN INJECTION INJURY AS A SIMPLE
CUT! Injection can lead to amputation. See a physician
immediately.
The maximum operating range of the sprayer is 3100 PSI / 21.4
MPa uid pressure.
PREVENTION:
NEVER aim the gun at any part of the body.
Do not aim the gun at, or spray any person or animal.
NEVER allow any part of the body to touch the uid stream.
DO NOT allow body to touch a leak in the uid hose.
NEVER put your hand in front of the gun. Gloves will not
provide protection against an injection injury.
ALWAYS lock the gun trigger, shut the pump off, and
release all pressure before servicing, cleaning the tip or
guard, changing tip, or leaving unattended. Pressure will
not be released by turning off the motor. The PRIME/
SPRAY valve or pressure bleed valve must be turned to
their appropriate positions to relieve system pressure.
Refer to the PRESSURE RELIEF PROCEDURE
described in this manual.
ALWAYS keep the tip guard in place while spraying. The
tip guard provides some protection but is mainly a warning
device.
ALWAYS remove the spray tip before ushing or cleaning
the system.
Paint hose can develop leaks from wear, kinking and
abuse. A leak can inject material into the skin. Inspect
the hose before each use. Do not use hose to lift or pull
equipment.
NEVER use a spray gun without a working trigger lock and
trigger guard in place.
All accessories must be rated at or above 3100 PSI / 21.4
MPa. This includes spray tips, guns, extensions, and hose.
Do not leave the unit energized or under pressure while
unattended. When the unit is not in use, turn off the unit and
relieve the pressure in accordance with the PRESSURE
RELIEF PROCEDURE described in this manual.
Verify that all connections are secure before operating the
unit. Unsecured parts may eject at great force or leak a
high pressure uid stream causing severe injury.
Always engage the trigger lock when not spraying. Verify
the trigger lock is functioning properly.
NOTE TO PHYSICIAN:
Injection into the skin is a traumatic injury. It is
important to treat the injury as soon as possible. DO
NOT delay treatment to research toxicity. Toxicity is a
concern with some coatings injected directly into the
blood stream. Consultation with a plastic surgeon or
reconstructive hand surgeon may be advisable.
HAZARD: HAZARDOUS VAPORS
Paints, solvents, insecticides, and other materials
can be harmful if inhaled or come in contact with the
body. Vapors can cause severe nausea, fainting, or
poisoning.
PREVENTION:
Use a respirator or mask if vapors can be
inhaled. Read all instructions supplied
with the mask to be sure it will provide the
necessary protection.
Wear protective eyewear.
Wear protective clothing as required by coating manufacturer.
HAZARD: EXPLOSION OR FIRE
Solvent and paint fumes can explode or ignite.
Property damage and/or severe injury can occur.
PREVENTION:
Provide extensive exhaust and fresh air introduction to
keep the air within the spray area free from accumulation
of ammable vapors. Solvent and paint fumes can
explode or ignite.
Do not spray in a conned area.
Avoid all ignition sources such as static electric sparks,
open ames, pilot lights, electrical appliances, and hot
objects. Connecting or disconnecting power cords or
working light switches can make sparks. Paint or solvent
owing through the equipment is able to result in static
electricity.
Do not smoke in spray area.
Fire extinguisher must be present and in good working
order.
Place pump at least 25 feet (7.62 meters) from the
spray object in a well ventilated area (add more hose if
necessary). Flammable vapors are often heavier than air.
Floor area must be extremely well ventilated. The pump
contains arcing parts that emit sparks and can ignite vapors.
The equipment and objects in and around the spray area
must be properly grounded to prevent static sparks.
Keep area clean and free of paint or solvent containers,
rags and other ammable materials.
Use only conductive or grounded high pressure uid hose.
Gun must be grounded through hose connections.
For electric units — power cord must be connected to a
grounded circuit.
Always ush unit into a separate metal container, at low
pump pressure, with spray tip removed. Hold gun rmly
against side of container to ground container and prevent
static sparks.
Follow the material and solvent manufacturer’s warnings
and instructions. Know the contents of the paints and
solvents being sprayed. Read all Material Safety Data
Sheets (MSDS) and container labels provided with
the paints and solvents. Follow the paint and solvent
manufacturer’s safety instructions.
Use extreme caution when using materials with
a ashpoint below 70ºF (21ºC). Flashpoint is the
temperature that a uid can produce enough vapors to
ignite.
Plastic can cause static sparks. Never hang plastic to
enclose a spray area. Do not use plastic drop cloths when
spraying ammable materials.
Use lowest possible pressure to ush equipment.
Do not spray onto pump assembly.
© SprayTECH. All rights reserved. 3
Important Safety Information · Read all safety information before
operating the equipment. SAVE THESE INSTRUCTIONS.
HAZARD: EXPLOSION HAZARD DUE TO
INCOMPATIBLE MATERIALS
Will cause property damage or severe injury.
PREVENTION:
Do not use materials containing bleach or
chlorine.
Do not use halogenated hydrocarbon solvents such
as bleach, mildewcide, methylene chloride and 1,1,1 -
trichloroethane. They are not compatible with aluminum.
Contact your coating supplier about the compatibility of
material with aluminum.
HAZARD: GENERAL
Can cause severe injury or property damage.
PREVENTION:
Read all instructions and safety precautions before
operating equipment.
Follow all appropriate local, state, and national codes
governing ventilation, re prevention, and operation.
The United States Government Safety Standards have
been adopted under the Occupational Safety and Health
Act (OSHA). These standards, particularly part 1910 of
the General Standards and part 1926 of the Construction
Standards should be consulted.
Use only manufacturer authorized parts. User assumes
all risks and liabilities when using parts that do not meet
the minimum specications and safety requirements of the
pump manufacturer.
All hoses, ttings, and lter parts must be secured before
operating spray pump. Unsecured parts can eject at great
force or leak a high pressure uid stream causing severe
injury.
Before each use, check all hoses for cuts, leaks, abrasion
or bulging of cover. Check for damage or movement of
couplings. Immediately replace the hose if any of these
conditions exist. Never repair a paint hose. Replace it with
another grounded high-pressure hose.
Do not kink or over-bend the hose. Airless hose can
develop leaks from wear, kinking and abuse. A leak can
inject material into the skin.
Do not expose the hose to temperatures or pressures in
excess of those specied by manufacturer.
Do not spray outdoors on windy days.
Wear clothing to keep paint off skin and hair.
Do not operate or spray near children. Keep children
away from the equipment at all times.
Do not overreach or stand on an unstable support. Keep
effective footing and balance at all times.
Use lowest possible pressure to ush equipment.
Stay alert and watch what you are doing.
Do not operate the unit when fatigued or under the
inuence of drugs or alcohol.
For electric units — Always unplug cord from outlet before
working on equipment.
Do not use the hose as a strength member to pull or lift the
equipment.
Do not lift by cart handle when loading or unloading.
Grounding Instructions
This product must be grounded. In the event of an electrical
short circuit, grounding reduces the risk of electric shock by
providing an escape wire for the electric current. This product is
equipped with a cord having a grounding wire with an appropriate
grounding plug. The plug must be plugged into an outlet that
is properly installed and grounded in accordance with all local
codes and ordinances.
WARNING - Improper installation of the grounding plug can
result in a risk of electric shock.
If repair or replacement of the cord or plug is necessary, do not
connect the green grounding wire to either at blade terminal.
The wire with insulation having a green outer surface with
or without yellow stripes is the grounding wire and must be
connected to the grounding pin.
Check with a qualied electrician or serviceman if the grounding
instructions are not completely understood, or if you are in doubt
as to whether the product is properly grounded. Do not modify
the plug provided. If the plug will not t the outlet, have the
proper outlet installed by a qualied electrician.
Grounded Outlet
Grounding Pin
Cover for grounded outlet box
IMPORTANT: Use only a 3-wire extension cord that has
a 3-blade grounding plug and a 3-slot receptacle that will
accept the plug on the product. Make sure your extension
cord is in good condition. When using an extension cord,
be sure to use one heavy enough to carry the current your
product will draw. An undersized cord will cause a drop in
line voltage resulting in loss of power and overheating. A 12
gauge cord is recommended. If an extension cord is to be
used outdoors, it must be marked with the suffix W-A after
the cord type designation. For example, a designation of
SJTW-A would indicate that the cord would be appropriate
for outdoor use.
Specications
Gallons per minute (GPM) ........ 0.85 (3.2 LPM)
Maximum tip sizes .................... One gun - 0.029”
Two guns - 0.017”
Maximum pressure ................... 3100 PSI (21.4 MPa)
Power ....................................... 1.95 HP PMDC brushless motor,
120VAC
Weight ...................................... 80 lbs. (36.3 kg)
Maximum hose length .............. 300’ (91.4 m)
4 © SprayTECH. All rights reserved.
Table of Contents
Safety Precautions ................................................................... 2
Specications ........................................................................... 3
General Description ................................................................. 4
Operation ................................................................................... 4
Setup ................................................................................... 4
Preparing to Paint................................................................ 4
Painting ............................................................................... 5
Pressure Relief Procedure .................................................. 6
Spraying .................................................................................... 6
Spraying Technique ............................................................ 6
Practice ............................................................................... 6
Unclogging the Spray Tip .................................................... 7
Cleanup ..................................................................................... 7
Cleaning the Spray Tip ........................................................ 7
Maintenance .............................................................................. 7
General Repair and Service Notes...................................... 7
Replacing the PRIME/SPRAY Valve ................................... 8
Replacing the Filters............................................................ 8
Replacing the Motor Assembly (with Electronic Control) .... 9
Replacing the Gears............................................................ 9
Replacing the Transducer ................................................. 10
Servicing the Fluid Section ................................................ 10
Troubleshooting ..................................................................... 12
Parts List ................................................................................. 18
Main Assembly .................................................................. 18
Drive Assembly ................................................................. 19
Fluid Section Assembly ..................................................... 20
Upright Cart Assembly ...................................................... 21
Filter Assembly .................................................................. 21
Suction Set Assembly (low boy) ........................................ 22
Low Boy Cart Assembly .................................................... 22
Labels ................................................................................ 22
Electrical Schematic .......................................................... 23
Accessories ....................................................................... 23
Limited Warranty .................................................................... 24
General Description
This airless sprayer is a precision power tool used for spraying
many types of materials. Read and follow this Owner’s Manual
carefully for proper operating instructions, maintenance, and
safety information.
Siphon
Tube
Pressure
Control
Knob
Oil Cup
Fuse
Fluid
Section
Filter
Motor
PRIME/
SPRAY
Valve
Outlet
Fitting
Return
Hose
Operation
This equipment produces a fluid stream at extremely
high pressure. Read and understand the warnings
in the Safety Precautions section at the front of this
manual before operating this equipment.
Setup
Perform the following procedure before plugging in the power
cord of an electric unit.
1. Ensure that the siphon tube and the return hose are
attached and secure.
2. Using a wrench, attach a minimum of 50’ of 1/4” airless
spray hose to the outlet tting on the sprayer. Tighten
securely.
3. Attach an airless spray gun to the spray hose. Using two
wrenches (one on the gun and one on the hose), tighten
securely.
NOTE: Do not attach the tip to the spray gun yet.
Remove the tip if it is already attached.
Make sure all airless hoses and spray guns are
electrically grounded and rated at or above the
maximum operating pressure range of the airless
sprayer.
4. Make sure the pressure control knob is in the “0” (OFF)
position.
5. Fill the oil cup with approximately one tablespoon of
separating oil (P/N 0279920).
IMPORTANT: Never operate unit for more than ten seconds
without fluid. Operating this unit without fluid will cause
unnecessary wear to the packings.
6. Make sure the electrical service is 120V, 15 amp
minimum.
7. Plug the power cord into a properly grounded outlet at
least 25’ from the spray area.
IMPORTANT: Always use a minimum 12 gauge, three-wire
extension cord with a grounded plug. Never remove the
third prong or use an adapter.
Preparing a New Sprayer
If this sprayer is new, it is shipped with test uid in the uid
section to prevent corrosion during shipment and storage. This
uid must be cleaned out of the system thoroughly with mineral
spirits before spraying paint.
IMPORTANT: Always keep the trigger lock on the spray gun
in the locked position while preparing the system.
1. Place the siphon tube into a container of mineral spirits.
2. Place the return hose into a metal waste container.
3. Move the PRIME/SPRAY valve down to the PRIME
position.
4. Turn on the sprayer and set the pressure to minimum by
turning the pressure control knob to the “1” or “2” position.
Priming and
Cleaning Zone
(minimum PSI)
0 = OFF
(0 PSI)
Pressure Control Knob
8 = 3100 PSI
(maximum PSI)
5. Allow the sprayer to run for 15–30 seconds to ush the
test uid out through the return hose and into the waste
container.
6. Turn off the sprayer by moving the pressure control knob to
the “0” position.
© SprayTECH. All rights reserved. 5
Preparing to Paint
Before painting, it is important to make sure that the uid in the
system is compatible with the paint that is going to be used.
NOTE: Incompatibleuidsandpaintmaycausethe
valves to become stuck closed, which would
require disassembly and cleaning of the
sprayer’suidsection.
IMPORTANT: Always keep the trigger lock on the spray gun
in the locked position while preparing the system.
1. Place the siphon tube into a container of the appropriate
solvent. Examples of the appropriate solvent are water for
latex paint or mineral spirits for oil-based paints.
2. Place the return hose into a metal waste container.
3. Move the PRIME/SPRAY valve down to the
PRIME position.
NOTE: Hold the return hose in the waste
container when moving the PRIME/
SPRAY valve to PRIME in case the
sprayer is pressurized.
4. Set the pressure to minimum by turning
the pressure control knob to the “1” or “2”
position.
5. Allow the sprayer to run for 15–30 seconds
to ush the old solvent out through the
return hose and into the metal waste
container.
6. Turn off the sprayer off by moving the pressure control
knob to the “0” position.
NOTE: Make sure that the spray gun does not have a tip
or tip guard installed.
7. Move the PRIME/SPRAY valve up to the
SPRAY position.
8. Turn on the sprayer and set the pressure
to minimum by turning the pressure control
knob to the “1” or “2” position.
9. Unlock the gun by turning the gun trigger lock to the
unlocked position.
Ground the gun by holding it
against the edge of the metal
container while flushing. Failure to
do so may lead to a static electric
discharge, which may cause a fire.
10. Trigger the gun into the metal waste container until the old
solvent is gone and fresh solvent is coming out of the gun.
11. Lock the gun by turning the gun trigger lock to the locked
position.
12. Set down the gun and increase the pressure by turning
the pressure control knob slowly clockwise to the “4” or “5”
position.
13. Check the entire system for leaks. If leaks occur, turn off
the sprayer and follow the “Pressure Relief Procedure” in
this manual before tightening any ttings or hoses.
14. Follow the “Pressure Relief Procedure” in this manual
before changing from solvent to paint.
Be sure to follow the pressure relief procedure
when shutting down the sprayer for any purpose,
including servicing or adjusting any part of the
spray system, changing or cleaning spray tips, or
preparing for cleanup.
Painting
1. Place the siphon tube into a container of paint.
2. Place the return hose into a metal waste container.
3. Move the PRIME/SPRAY valve down to the
PRIME position.
NOTE: Hold the return hose in the waste
container when moving the PRIME/
SPRAY valve to PRIME in case the
sprayer is pressurized.
4. Turn on the sprayer and set the pressure
to minimum by turning the pressure control
knob to the “1” or “2” position.
5. Allow the sprayer to run until paint is coming
through the return hose into the metal waste
container.
6. Turn off the sprayer by moving the pressure control knob to
the “0” position.
7. Remove the return hose from the waste container and place
it in its operating position above the container of paint.
8. Move the PRIME/SPRAY valve up to the
SPRAY position.
9. Turn on the sprayer and set the pressure
to minimum by turning the pressure control
knob to the “1” or “2” position.
10. Unlock the gun by turning the gun trigger
lock to the unlocked position.
Ground the gun by holding it
against the edge of the metal
container while flushing. Failure to
do so may lead to a static electric
discharge, which may cause a fire.
11. Trigger the gun into the metal waste container until all air
and solvent is ushed from the spray hose and paint is
owing freely from the gun.
12. Lock the gun by turning the gun trigger lock to the locked
position.
13. Turn off the sprayer by moving the pressure control knob
to the “0” position.
14. Attach tip guard and tip to the gun as instructed by the tip
guard or tip manuals.
POSSIBLE INJECTION HAZARD. Do not spray
without the tip guard in place. Never trigger the gun
unless the tip is in either the spray or the unclog
position. Always engage the gun trigger lock before
removing, replacing or cleaning tip.
15. Turn on the sprayer and set the pressure to minimum by
turning the pressure control knob to the “1” or “2” position.
16. Increase the pressure by turning the pressure control
knob slowly clockwise and test the spray pattern on a
piece of cardboard. Adjust the pressure control knob until
the spray from the gun is completely atomized. Try to
keep the pressure control knob at the lowest setting that
maintains good atomization.
NOTE: Turning the pressure up higher than needed to
atomize the paint will cause premature tip wear
and additional overspray.
6 © SprayTECH. All rights reserved.
Pressure Relief Procedure
Be sure to follow the pressure relief procedure
when shutting the unit down for any purpose,
including servicing or adjusting any part of the
spray system, changing or cleaning spray tips, or
preparing for cleanup.
1. Lock the gun by turning the gun trigger lock to the locked
position.
2. Turn the pressure control knob to the “0” (OFF) position.
3. Unlock the gun by turning the gun trigger lock to the
unlocked position.
4. Hold the metal part of the gun rmly
to the side of a metal container to
ground the gun and avoid a build up
of static electricity.
5. Trigger the gun to remove any
pressure that may still be in the hose.
6. Lock the gun by turning the gun trigger lock
to the locked position.
7. Move the PRIME/SPRAY valve down to the
PRIME position.
Spraying
NOTE: Whensprayingblockller,masticsorhighsolid
coating,removethegunlterandhighpressure
lterscreens.
Spraying Technique
The key to a good paint job is an even coating over the entire
surface. This is done by using even strokes. Keep your arm
moving at a constant speed and keep the spray gun at a constant
distance from the surface. The best spraying distance is 10 to 12
inches between the spray tip and the surface.
Keep stroke smooth and at an even speed.
Even coat throughout
Approximately
10 to 12 inches
Keep the spray gun at right angles to the surface. This means
moving your entire arm back and forth rather than just exing
your wrist.
Heavy Coat
Do not flex wrist while spraying.
Light Coat Light Coat
Keep the spray gun perpendicular to the surface, otherwise one
end of the pattern will be thicker than the other.
Approximately
10 to 12 inches
Right way
Wrong way
The spray gun should be triggered by turning it on and off with
each stroke. This will save paint and avoid paint buildup at
the end of the stroke. Do not trigger the gun during the middle
of a stroke. This will result in an uneven spray and splotchy
coverage.
Proper way to trigger the spray gun
Approximately
10 to 12 inches
Keep stroke
even
Start stroke End strokePull trigger Release triggerKeep steady
Overlap each stroke by about 30%. This will ensure an even
coating.
When you stop painting, lock the gun trigger lock, turn the
pressure control knob counterclockwise to its lowest setting and
set the PRIME/SPRAY valve to PRIME. Turn the ON/OFF switch
to the OFF position and unplug the sprayer.
Practice
1. Be sure that the paint hose is free of kinks and clear of
objects with sharp cutting edges.
2. Set the pressure to minimum by turning the pressure
control knob to the “1” or “2” position.
3. Move the PRIME/SPRAY valve up to the
SPRAY position.
4. Turn the pressure control knob clockwise to
its highest setting. The paint hose should
stiffen as paint begins to ow through it.
5. Unlock the gun trigger lock.
6. Trigger the spray gun to bleed air out of the hose.
7. When paint reaches the spray tip, spray a test area to
check the spray pattern.
Good spray pattern
Paint tailing pattern
8. Use the lowest pressure setting
necessary to get a good spray
pattern. If the pressure is set
too high, the spray pattern will
be too light. If the pressure is
set too low, tailing will appear
or the paint will spatter out
in gobs rather than in a ne
spray.
© SprayTECH. All rights reserved. 7
Cleanup
Do not use gasoline to clean the sprayer.
Special cleanup instructions for use with
flammable solvents:
Always ush spray gun preferably outside and at least one
hose length from spray pump.
If collecting ushed solvents in a one gallon metal
container, place it into an empty ve gallon container, then
ush solvents.
Area must be free of ammable vapors.
Follow all cleanup instructions.
IMPORTANT: The sprayer, hose, and gun should be cleaned
thoroughly after daily use. Failure to do so permits material
to build up, seriously affecting the performance of the unit.
Always spray at minimum pressure with the gun
nozzle tip removed when using mineral spirits or
any other solvent to clean the sprayer, hose, or
gun. Static electricity buildup may result in a fire
or explosion in the presence of flammable vapors.
1. Follow the “Pressure Relief Procedure” found in the
Operation section of this manual.
2. Remove the gun tip and tip guard and clean with a brush
using the appropriate solvent.
3. Place the siphon tube into a container of the appropriate
solvent. Examples of the appropriate solvent are water for
latex paint or mineral spirits for oil-based paints.
4. Place the return hose into a metal waste container.
5. Move the PRIME/SPRAY valve down to the
PRIME position.
NOTE: Hold the return hose in the waste
container when moving the PRIME/
SPRAY valve to PRIME in case the
sprayer is pressurized.
6. Turn on the sprayer and set the pressure
to minimum by turning the pressure control
knob to the “1” or “2” position.
7. Allow the solvent to circulate through the
unit and ush the paint out of the return
hose into the metal waste container.
8. Turn off the sprayer by moving the pressure
control knob to the “0” position.
9. Move the PRIME/SPRAY valve up to its
SPRAY position.
10. Turn on the sprayer and set the pressure
to minimum by turning the pressure control
knob to the “1” or “2” position.
Ground the gun by holding it
against the edge of the metal
container while flushing. Failure to
do so may lead to a static electric
discharge, which may cause a fire.
11. Trigger the gun into the metal waste container until the
paint is ushed out of the hose and solvent is coming out
of the gun.
12. Continue to trigger the spray gun into the waste container
until the solvent coming out of the gun is clean.
NOTE: For long-term or cold weather storage, pump
mineral sprits or Pump Saver Plus through the
entire system.
13. Follow the “Pressure Relief Procedure” found in the
Operation section of this manual.
14. Unplug the sprayer and store in a clean, dry area.
IMPORTANT: Do not store the unit under pressure.
Cleaning the Spray Tip
1. Flush the gun with solvent immediately after the work is
completed.
2. Oil the sliding pins to prevent them from seizing up.
Do not attempt to clean the tip with
your finger.
Do not use a needle or other sharp
pointed instrument to clean the tip.
The hard tungsten carbide is brittle
and can be chipped.
Maintenance
Before proceeding, follow the Pressure Relief
Procedure outlined previously in this manual.
Additionally, follow all other warnings to reduce the
risk of an injection injury, injury from moving parts
or electric shock. Always unplug the sprayer
before servicing!
General Repair and Service Notes
The following tools are needed when repairing this sprayer:
Phillips Screwdriver 3/8” Hex Wrench
Needle Nose Pliers 5/16” Hex Wrench
Adjustable Wrench 1/4” Hex Wrench
Rubber Mallet 3/16” Hex Wrench
Flat-blade Screwdriver 5/32” Hex Wrench
1. Before repairing any part of the sprayer, read the
instructions carefully, including all warnings.
IMPORTANT: Never pull on a wire to disconnect it. Pulling
on a wire could loosen the connector from the wire.
2. Test your repair before regular operation of the sprayer
to be sure that the problem is corrected. If the sprayer
does not operate properly, review the repair procedure to
determine if everything was done correctly. Refer to the
Troubleshooting section to help identify other possible
problems.
3. Make sure that the service area is well ventilated in
case solvents are used during cleaning. Always wear
protective eyewear while servicing. Additional protective
equipment may be required depending on the type of
cleaning solvent. Always contact the supplier of solvents
for recommendations.
4. If you have any further questions concerning your
SprayTECH Airless Sprayer, call SprayTECH:
Technical Service (U.S.) ....................... 1-800-526-5362
Fax ................................................ 1-800-525-9501
8 © SprayTECH. All rights reserved.
Replacing the PRIME/SPRAY Valve
Perform the following procedure using PRIME/SPRAY valve
replacement kit P/N 0507690.
1. Drive the groove pin out of the valve handle.
2. Remove the valve handle and the cam base.
3. Using a wrench, loosen and remove the valve housing
assembly.
4. Make sure the gasket is in place and thread the new valve
housing assembly into the lter block. Tighten securely
with a wrench.
5. Place the cam base over the valve housing assembly.
Lubricate the cam base with grease and line up the cam
with the lter block using the dowel pin.
6. Line up the hole on the valve stem with the hole in the
valve handle.
7. Insert the groove pin into the valve handle and through the
valve stem to secure the valve handle in position.
Replacing the Filters
Pump Filter
Filter
Body
Core
Spring
Filter
O-ring
Filter
Housing
1. Loosen and remove the lter
housing by hand. Pull the lter
out of the pump manifold.
2. Slip the lter off of the lter
support spring.
3. Inspect the lter. Based on
inspection, clean or replace the
lter.
4. Inspect the lter seal. Based on
inspection, clean or replace the
lter seal.
5. Slide the new or cleaned lter
over the lter support spring with
the adapter in place. Push the
lter into the center of the pump
manifold.
6. Slide the lter housing over the
lter and thread it into the pump
manifold until secure.
NOTE: Thelterhousingshould
be hand-tightened, but
makesurethelter
housing is seated fully
into the pump manifold.
Gun Filter
Gun
Housing
Filter
Handle
Handle
Seal
1. Pull the bottom of the trigger
guard forward so that it
comes loose from the handle
assembly.
2. Loosen and remove the handle
assembly from the gun head.
3. Pull the old lter out of the gun
head.
4. Slide the new lter, tapered
end rst, into the gun head.
5. Make sure the handle seal is in
position and thread the handle
assembly into the gun head
until secure.
6. Snap the trigger guard back onto the handle assembly.
Choosing the Correct Spray Gun Filter
Use the proper gun lter based on the type of material being
applied as shown below.
Part
Number
Application Filter
Type
Color of
Filter
Body
0089960 Synthetic resin,
enamels, clean
varnishes, stains
azures
Extrafine red
0089959 Base coat enamels,
primer enamels,
fillers, marking paints,
textured enamels
Fine yellow
0089958 Emulsions,
latex paints,
acrylic paints
Medium white
0089957 Heavy bodied latex,
blockfillers,
elastometrics
Coarse green
NOTE: For more detail, part number information, and
an assembly drawing, please see the G-10 XL
Airless Spray Gun Owner’s Manual (P/N 0296237).
© SprayTECH. All rights reserved. 9
Replacing the Motor Assembly (with
Electronic Control)
Electrostatic discharge (ESD) potential could cause
damage to electronic control. Use SprayTECH ESD
wrist strap P/N 0507958 or equivalent when
working on electronic control with electronic cover
removed.
1. Perform the Pressure Relief Procedure and unplug the
sprayer.
2. Turn the pressure control knob to the “1” or “2” position to
make sure the power supply has discharged.
3. Loosen and remove the four motor shroud screws.
Remove the motor shroud.
4. Release the tie wrap on the top of the bafe assembly and
slip the bafe assembly down off of the motor.
5. Loosen and remove the three electronic cover screws. Lift
the electronic cover off of the electronic control assembly
on the motor.
6. At the electronic control assembly:
a. Disconnect the white wire coming from the power cord and
the white wire coming from the relay.
b. Disconnect the three wires coming from the potentiometer.
7. Loosen and remove the three motor mounting screws.
8. Pull the motor out of the gearbox housing.
9. With the motor removed, inspect the gears in the gearbox
housing for damage or excessive wear. Replace the
gears, if necessary.
10. Install the new motor into the gearbox housing. Make sure
the housing gasket is positioned properly.
11. Secure the motor with the three motor mounting screws.
12. Reconnect the wires to the electronic control assembly
(refer to the electrical schematic in the Parts List section of
this manual).
13. Position the electronic cover over the electronic control
assembly. Secure the electronic cover with the three
electronic cover screws.
IMPORTANT: Use only SprayTECH electronic cover screws
to secure the electronic cover (see Drive Assembly parts
list). Use of any other screws may damage the electronic
control assembly.
14. Slip the bafe assembly up and around the motor. Secure
the bafe assembly with the tie wrap.
15. Slide the motor shroud over the motor.
16. Secure the motor shroud with the four motor shroud
screws.
Electronic Cover
Motor Shroud
Motor Shroud Screws
Motor
Baffle Assembly
Housing Gasket
Electronic Control
Assembly
Motor Mounting
Screw
Electronic Cover
Screw
Gearbox
Housing
Replacing the Gears
1. Perform the Pressure Relief Procedure and unplug the
unit.
2. Turn the pressure control knob to the “1” or “2” position to
make sure the power supply has discharged.
3. Loosen and remove the four motor shroud screws.
Remove the motor shroud.
4. Release the tie wrap on the top of the bafe assembly and
slip the bafe assembly down off of the motor.
5. Loosen and remove the three electronic cover screws. Lift
the electronic cover off of the electronic control assembly
on the motor.
6. At the electronic control assembly:
a. Disconnect the white wire coming from the power
cord and the white wire coming from the relay.
b. Disconnect the three wires coming from the
potentiometer.
7. Loosen and remove the three motor mounting screws.
8. Pull the motor out of the gearbox housing.
9. Inspect the armature gear on the end of the motor for
damage or excessive wear. If this gear is completely worn
out, replace the motor.
10. Remove and inspect the 1st stage gear and 2nd stage
gear assemblies for damage or excessive wear. Replace,
if necessary.
11. Remove and inspect the front gear box assembly for
damage or excessive wear. If damaged or worn, replace
the front gear box assembly.
NOTE: Cleanandrellthegearboxcavityuptotherear
face of each gear with grease (P/N 9870307).
12. Install the motor into the gearbox housing. Make sure the
housing gasket is positioned properly.
13. Secure the motor with the three motor mounting screws.
14. Reconnect the wires to the electronic control assembly
(refer to the electrical schematic in the Parts List section of
this manual).
15. Position the electronic cover over the electronic control
assembly. Secure the electronic cover with the three
electronic cover screws.
16. Slip the bafe assembly up and around the motor. Secure
the bafe assembly with the tie wrap.
17. Slide the motor shroud over the motor.
18. Secure the motor shroud with the four motor shroud
screws.
Front End Bell
Assembly
Armature Gear
1st Stage Gear
2nd Stage Gear
Front Gear Box
Assembly
Housing
Gasket
10 © SprayTECH. All rights reserved.
Replacing the Transducer
1. Perform the Pressure Relief Procedure and unplug the
unit.
2. Turn the pressure control knob to the “1” or “2” position to
make sure the power supply has discharged.
3. Loosen and remove the four motor shroud screws.
Remove the motor shroud.
4. At the electronic control assembly, disconnect the black
wire coming from the transducer.
5. Pull the grommet out of the mounting plate and slide it up
the shaft of the transducer until it is clear of the mounting
plate.
Transducer
Transducer
Cap
Inner Seal
6. Using a wrench, loosen and remove
the transducer from the lter housing.
Carefully thread the transducer wire out
through the mounting plate. Replace
the transducer cap and inner seal, if
damaged.
7. Slide the grommet off of the old
transducer and onto the new transducer.
8. Thread the new transducer wire through the mounting
plate and up to the electronic control assembly.
9. Thread the new transducer into the lter housing and
tighten securely with a wrench.
NOTE: Make sure the transducer cap and inner seal on
the transducer are in place before threading the
transducerintothelterhousing.
10. Push the grommet into the mounting plate.
11. Connect the transducer wire to the electronic control
assembly (refer to the electrical schematic in the Parts List
section of this manual).
12. Slide the motor shroud over the motor.
13. Secure the motor shroud with the four motor shroud
screws.
Motor Shroud
Transducer
Grommet
Motor Shroud Screws
Electronic
Control
Assembly
Mounting Plate
To Filter
Servicing the Fluid Section
Use the following procedures to service the valves and repack
the uid section.
1. Loosen and remove the four front cover screws. Remove
the front cover.
2. Position the crankshaft/slider assembly at the bottom,
dead-center of its stroke so that the connecting pin and
retaining ring are visible below the slider assembly. This is
done by turning the sprayer on and off in short bursts until
the connecting pin is visible below the slider housing.
3. Turn off and unplug the unit.
Before proceeding, follow the Pressure Relief
Procedure outlined previously in this manual.
Additionally, follow all other warnings to reduce the
risk of an injection injury, injury from moving parts
or electric shock. Always unplug the sprayer
before servicing!
4. Remove the return hose from the clamp on the siphon
tube.
5. Unscrew the siphon tube/suction set from the inlet valve.
6. Loosen and remove the high-pressure hose from the
nipple on the back of the cylinder of the uid section.
Retaining
Ring
Connecting
Pin
Slider
Assembly
Crankshaft
Jam Nut
Cylinder
7. Slide the retaining ring up on the
slider assembly to expose the
connecting pin.
8. Push the connecting pin forward
through the slider assembly and
piston. The connecting pin will
fall into a recessed area of the
gear box housing where it can be
retrieved.
9. Using a wrench, turn the jam nut
counterclockwise to loosen it from
the gear box housing.
10. Turn the uid section
counterclockwise to remove it from
the gear box housing.
11. Place the uid section cylinder
upright in a vise by clamping on
the wrench ats.
NOTE: Do not over-tighten the vise. Damage to the
cylinder may occur.
Inlet Valve
Housing
Viton
O-Ring
O-ring
PTFE
Back-Up
Ring
Inlet Valve
Seat
Inlet Valve
Ball
Inlet Valve
Cage
Cylinder
12. Loosen and remove the inlet
valve housing from the cylinder.
13. Remove the inlet valve cage, inlet
valve ball, inlet valve seat, and
o-ring from the inlet valve.
14. Clean out any debris in the inlet
valve housing and examine the
housing and the inlet valve seat.
If the seat is damaged, reverse or
replace the seat.
15. Using a wrench, remove the
upper seal retainer.
16. Slide the piston rod out through
the bottom of the cylinder.
17. Inspect the piston rod for wear
and replace if necessary.
18. Remove the upper packing
assembly from the top of the
cylinder.
19. Remove the adapter and lower packing assembly from the
bottom of the cylinder.
NOTE: Be careful not to scratch, score, or otherwise
damage the cylinder during removal of the
packings.
© SprayTECH. All rights reserved. 11
Piston Rod
Cylinder
Upper
Seal
Retainer
Upper
Packing
Assembly
Adapter
Outlet Valve
Seal
Outlet Valve
Cage
Nylon
Washer
Outlet Valve
Ball
Outlet Valve
Seat
Outlet Valve
Retainer
Upper
Support
Ring
Lower
Packing
Assembly
20. Remove the cylinder from the
vise.
21. Insert the connection pin through
the hole at the top of the piston
rod and clamp each end of the
connecting pin in the vise. This
will hold the piston rod in position
for disassembly.
NOTE: Do not clamp the piston
rod directly in the vise.
Damage to the piston rod
will occur.
22. Using a 3/8” hex wrench, loosen
and remove the outlet valve
retainer from the piston rod.
23. Remove the outlet valve seat,
outlet valve ball, nylon washer,
outlet valve cage, and outlet valve
seal from the piston rod.
24. Clean out any debris and examine
the retainer and outlet valve seat.
If the seat is damaged, reverse or
replace the seat.
25. Clean and inspect the outlet
valve cage and outlet valve
ball. Replace if they are worn or
damaged.
26. Reassemble the outlet valve
assembly into the piston rod in
the reverse order of how it was
disassembled. Torque the outlet
valve retainer to 12 ft. lbs.
27. Remove the piston rod from the
vise.
28. Clean the cylinder. Inspect the
cylinder for damage and replace if
necessary.
29. Place the cylinder upright in a vise
by clamping on the wrench ats.
30. Locate the new upper and lower
packings and remove the pre-form
tools. Save the upper packing pre-form tool for use as the
piston insertion tool later in this procedure.
NOTE: Do not remove the pre-form tools from the upper
and lower packings until immediately before they
are installed into the cylinder.
Install upper packing
with raised lip
facing down.
Raised Lip
31. Pack the areas between the
packing lips with grease.
Lubricate the o-rings on the
exterior of the packings with
grease.
32. Insert the upper packing into the
top of the cylinder with the raised
lip on the packing facing down
toward the cylinder.
33. Insert the upper support ring on top of the upper packing.
Large Beveled Edge
Install lower packing so
large beveled edge will
be facing up when the
cylinder is upright.
34. Thread the upper seal retainer into
the cylinder and torque to 25-30 ft.
lbs.
35. Rotate the cylinder in the vise so
that the bottom end is facing up.
36. Insert the lower packing partially
into the bottom of the cylinder with
the large beveled edge facing
toward the cylinder (beveled edge
will be facing up when the cylinder
is upright).
37. Push the lower packing assembly into position using the
lower packing insertion tool (see Fluid Section Assembly
parts list for lower packing insertion tool P/N).
NOTE: Coat the piston insertion tool (i.e. upper packing
pre-form tool) and the piston rod with grease
before inserting them into the cylinder.
38. Place the piston insertion tool over the top of the piston
rod.
39. Insert the piston rod into the bottom of the cylinder,
through the lower packing assembly, through the upper
packing assembly, and out through the upper seal
retainer.
NOTE: Make sure the raised lip on the bottom of the
lower packing is fully outside the packing around
the piston rod after insertion of the piston rod.
40. Remove the piston insertion tool from the top of the piston
rod.
41. Turn the jam nut counterclockwise until it is ush against
the top of the cylinder.
42. Lubricate the threads on the cylinder with anti-seize
compound. Remove the cylinder from the vise.
43. Thread the cylinder into the gear box housing, turning
clockwise. When the connecting pin hole on the piston
rod lines up with the hole in the slider assembly, insert the
connecting pin.
44. Slide the retaining ring down over the connecting pin.
45. Continue to turn the cylinder clockwise until the jam nut is
ush against the gear box housing.
NOTE: If the nipple on the cylinder does not face
the back of the unit, turn the cylinder
counterclockwise until the nipple faces the back
of the unit. Do not turn the cylinder more than
one full turn.
46. Once the nipple is positioned, turn the jam nut clockwise
until it contacts the gear box housing.
47. Tighten the jam nut with a wrench to tighten it against the
gear box housing.
48. Attach the high-pressure hose to the nipple on the back
of the cylinder and tighten with a wrench. Do not kink the
hose.
NOTE: For low rider units, make sure the hose does not
touch the cart frame. If it does, reposition the
nipple by turning the cylinder until the hose is
clear of the frame and the nipple is within 45º of
the back of the unit.
49. Insert the adapter into the bottom of the cylinder.
50. Making sure that the Viton o-ring and PTFE back-up ring
are lubricated and in place, reassemble the inlet valve
assembly and and thread it into the cylinder. Tighten the
inlet valve housing until the o-ring engages, then continue
to tighten until snug. Once snug, tighten an additional
1/8–1/4 turn.
51. Thread the siphon tube/suction set into the inlet valve
housing and tighten securely. Make sure to wrap the
threads on the down tube/siphon hose adapter with PTFE
tape before assembly.
52. Replace the return hose into the clamp on the siphon tube.
53. Place the front cover on the gearbox housing and secure
in position using the four front cover screws.
54. Turn on the sprayer by following the procedure in the
“Operation” section of this manual and check for leaks.
NOTE: Repacking kit P/N 0551687 is available. For best
results use all parts supplied in this kit.
12 © SprayTECH. All rights reserved.
Problem
A. The unit will not run.
B. The unit will not prime.
C. The unit will not build or
maintain pressure.
D. Fluid leakage at the upper end
of the uid section.
E. Excessive surge at the spray
gun.
F. Poor spray pattern.
G. The unit lacks power.
Cause
1. The unit is not plugged in.
2. Tripped breaker.
3. The pressure is set too low (pressure
control knob set at minimum setting does
not supply power to unit).
4. Faulty or loose wiring.
5. Excessive motor temperature.
1. The PRIME/SPRAY valve is in the SPRAY
position.
2. Air leak in the siphon tube/suction set.
3. The pump lter and/or inlet screen is
clogged.
4. The siphon tube/suction set is clogged.
1. The spray tip is worn.
2. The spray tip is too large.
3. The pressure control knob is not set
properly.
4. The pump lter, gun lter, or inlet screen is
clogged.
5. Material ows from the return hose when
the PRIME/SPRAY valve is in the SPRAY
position.
6. Air leak in the siphon tube/suction set.
7. There is external uid leak.
8. There is an internal uid section leak
(packings are worn and/or dirty, valve balls
are worn).
9. Worn valve seats
10. Motor powers but fails to rotate
1. The upper packings are worn.
2. The piston rod is worn.
1. Wrong type of airless spray hose.
2. The spray tip worn or too large.
3. Excessive pressure.
1. The spray tip is too large for the material
being used.
2. Incorrect pressure setting.
3. Insufcient uid delivery.
4. The material being sprayed is too viscous.
1. The pressure adjustment is too low.
2. Improper voltage supply.
Solution
1. Plug the unit in.
2. Reset the breaker.
3. Turn the pressure control knob clockwise to supply
power to the unit and increase the pressure setting.
4. Inspect or take to a SprayTECH authorized service
center.
5. Allow motor to cool.
1. Rotate the PRIME/SPRAY valve clockwise to the
PRIME position.
2. Check the siphon tube/suction set connection and
tighten or re-tape the connection with PTFE tape.
3. Remove the pump lter element and clean. Remove
the inlet screen and clean.
4. Remove the siphon tube/suction set and clean.
1. Replace the spray tip following the instructions that
came with the spray gun.
2. Replace the spray tip with a tip that has a smaller
orice following the instructions that came with the
spray gun.
3. Turn the pressure control knob clockwise to increase
the pressure setting.
4. Remove the pump lter element and clean. Remove
the gun lter and clean. Remove the inlet screen
and clean.
5. Clean or replace the PRIME/SPRAY valve.
6. Check the siphon tube/suction set connection and
tighten or re-tape the connection with PTFE tape.
7. Check for external leaks at all connections. Tighten
connections, if necessary.
8. Clean the valves and service the uid section
following the “Servicing the Fluid Section” procedure
in the Maintenance section of this manual.
9. Reverse or replace the valve seats following the
“Servicing the Fluid Section” procedure in the
Maintenance section of this manual.
10. Take unit to a SprayTECH authorized service center.
1. Repack the pump following the “Servicing the Fluid
Section” procedure in the Maintenance section of this
manual.
2. Replace the piston rod following the “Servicing the
Fluid Section” procedure in the Maintenance section
of this manual.
1. Replace hose with a minimum of 50’ of 1/4”
grounded textile braid airless paint spray hose.
2. Replace the spray tip following the instructions that
came with the spray gun.
3. Rotate the pressure control knob counterclockwise to
decrease spray pressure.
1. Replace the spray tip with a new or smaller spray tip
following the instructions that came with the spray
gun.
2. Rotate the pressure control knob to adjust the
pressure for a proper spray pattern.
3. Clean all screens and lters.
4. Add solvent to the material according to the
manufacturer’s recommendations.
1. Rotate the pressure control knob clockwise to
increase the pressure setting.
2. Reconnect the input voltage for 120V AC.
Troubleshooting
© SprayTECH. All rights reserved. 13
Notes
Français
14 © SprayTECH. Tous droits réservés.
Consignes de sécurite important · Lire toutes ces consignes avant
d’utiliser l’appareil. GARDER CES CONSIGNES.
Indique une situation à risque, laquelle, si elle n’est pas
évitée, peut entraîner des blessures graves, voire la mort.
Pour réduire les risques d’incendie ou d’explosion, de
choc électrique et de blessure, vous devez lire et
comprendre les directives figurant dans ce manuel.
Familiarisez-vous avec les commandes et l’utilisation
adéquate de l’équipement.
DANGER : INJECTION CUTANÉE
Le jet de haute pression produit par cet appareil peut
transpercer la peau et les tissus sous-jacents, causant des
blessures graves pouvant entraîner l’amputation.
NE PAS TRAITER ce type de BLESSURE COMME UNE
SIMPLE COUPURE! Une amputation peut en résulter.
ON doit consulter un médicin sur-le-champ.
La pression maximale de ce pulvérisateur est d’environ 3 100 PSI / 21,4
MPa.
MESURES PRÉVENTIVES :
Ne pas pointer le pistolet vers une partie du corps.
Ne pas pointer le pistolet vers une personne ou un animal; ne pas
pulvériser non plus de produit dessus.
NE JAMAIS mettre une partie du corps devant le jet de produit.
NE JAMAIS toucher les fuites du exible de pulvérisation.
NE JAMAIS mettre la main, même gantée, devant le pistolet (les
gants n’offrent aucune protection contre les blessures par injection).
TOUJOURS verrouiller la détente, arrêter la pompe et relâcher
toute la pression avant d’effectuer la maintenance de l’appareil ou
de le laisser sans surveillance, d’en nettoyer le protège-embout
ou l’embout, ou de remplacer ce dernier. La pression ne sera
pas relâchée par le simple arrêt du moteur; pour ce faire, on
doit se servir du bouton PRIME/SPRAY (se reporter à la section
Comment libérer la pression, du présent manuel).
TOUJOURS s’assurer que le protège-embout est en place
avant de pulvériser. Il est cependant à noter que, s’il assure une
certaine protection, ce dispositif joue surtout un rôle préventif.
TOUJOURS retirer l’embout avant de vidanger ou de nettoyer
l’appareil.
toujours inspecter le exible avant de commencer; celui-ci peut
présenter des fuites attribuables à l’usure, à une exion excessibe
ou à un traitement abusif, lesquelles fuites présentent des risques
d’injection cutanée. Ne pas utiliser le exible pour soulever ou
tirer l’équipement.
NE JAMAIS utiliser de pistolet sans verrou de détente et protège-
doigts.
Tous les accessoires (pistolets, embouts, rallonges, exibles etc.)
doivent pouvoir subir une pression nominale de 3 100 PSI / 21,4
MPa ou plus.
Ne laissez pas l’appareil sous tension ou sous pression quand
vous vous en éloignez. Quand vous n’utilisez pas l’appareil,
éteignez-le et libérez la pression conformément aux instructions
Comment libérer la pression, du présent manuel.
Vériez que toutes les connexions sont bien serrées avant
d’utiliser l’appareil. Toute pièce qui n’est pas xée solidement
risque d’être projetée violemment ou d’entraîner la fuite d’un jet
de liquide à une pression extrêmement élevée, ce qui pourrait
causer des blessures graves.
Verrouillez toujours la détente quand vous ne pulvérisez pas.
Vériez que le verrou de la détente fonctionne correctement.
REMARQUE À L’INTENTION DES MÉDECINS :
Les injections cutanées sont des lésions traumatiques; il
importe donc de les traiter sans délai. On NE DOIT PAS retarder
cetraitementsousprétextedevérierlatoxicitéduproduiten
cause, celle-ci n’étant conséquente que dans le cas d’injection
directe de certains produits dans le système sanguin. Il pourrait
s’avérer nécessaire de consulter un plasticien ou un spécialiste
en chirurgie reconstructive de la main.
DANGER : ÉMANATIONS DANGEREUSES
Certains produits (peintures, solvants, insecticides ou
autres) peuvent être nocifs s’ils sont inhalés ou entrent en
contact avec l’organisme. Les émanations de ces produits
peuvent provoquer de graves nausées, évanouissements
ou empoisonnements.
MESURES PRÉVENTIVES :
Se servir d’un masque ou d’un respirateur s’il
y a risque d’inhalation (lire toutes les directives
concernant ces dispositifs an de s’assurer qu’ils
offrent la protection requise).
Porter des lunettes de protection.
Porter les vêtements de protection prescrits par le fabricant du
produit utilisé.
DANGER : EXPLOSION OU INCENDIE
Les émanations de certains produits peuvent exploser
ou s’enammer, et risquent d’entraîner des dommages
matériels ou de graves blessures.
MESURES PRÉVENTIVES :
S’assurer que l’aire de travail est dotée de moyens d’évacuation
d’air vicié et d’introduction d’air frais pour éviter l’accumulation de
vapeurs inammables. Les vapeurs dégagées par la peinture ou
les solvants peuvent provoquer une explosion ou s’enammer.
Ne pas pulvériser de produit dans un endroit clos.
Ne pas travailler près de sources d’ignition (décharges
électrostatiques ou étincelles provoquées par le branchement/
débranchement d’appareils ou la commutation d’interrupteurs,
d’appareils électriques, ammes nues, veilleuses, objets chauds,
etc.). La peinture ou le solvant s’écoulant dans l’équipement peut
générer de l’électricité statique.
Ne pas fumer dans l’aire de travail.
L’aire de travail doit être munie d’un extincteur en bon état de marche.
Prévoir un espace d’au moins 7.62 mètres entre la pompe et l’objet
à pulvériser s’ils sont dans la même pièce bien ventilée (rallonger le
exible au besoin). Les vapeurs inammables étant souvent plus lourdes
que l’air, l’espace au-dessus du plancher doit être particulièrement bien
aéré. La pompe contient des pièces qui produisent des arcs et émettent
des étincelles pouvant enammer les vapeurs.
Les appareils et objets à l’intérieur ou à proximité de l’aire de
travail doivent être adéquatement mis à la terre pour éviter les
décharges électrostatiques.
Veillez à ce que la zone soit propre et exempte de contenants de
peinture ou de solvant, chiffons ou autres matériaux inammables.
Les exibles dont on se sert doivent être conçus pour subir les
pressions élevées et faits de matériaux conducteurs ou mis à la
terre adéquatement; le pistolet sera mis à la terre par le biais de
ses raccords aux exibles.
Pour les appareils électriques — Le cordon d’alimentation doit
être branché à un circuit trilaire.
L’appareil doit toujours être vidangé à basse pression, embout
retiré, dans un contenant métallique distinct. Tenir le pistolet
contre la paroi du contenant de manière à mettre ce dernier à la
terre et à prévenir les décharges électrostatiques.
Toujours respecter les mises en garde et les directives du
fabricant des produits et solvants utilisés. On doit connaître les
produits contenus dans les peintures et solvants qu’on pulvérise.
Lire les ches techniques santé-sécurité (FTSS) et les étiquettes
des contenants fournies avec les peintures et solvants. Suivres
les consignes de sécurité du fabricant de peinture et de solvant.
S’entourer de toutes les précautions possibles lorsqu’on utilise
des produits ayant un point d’éclair inférieur à 21°C (70°F). Le
point d’éclair est la température à laquelle le liquide peut créer
sufsamment de vapeurs et s’enammer.
Le plastique est générateur de décharges électrostatiques; ne jamais
en suspendre pour fermer une aire de travail ou en utiliser en guise
de toile de protection lorsqu’on pulvérise un produit inammable.
Se servir de la pression la plus basse possible pour vidanger
l’appareil.
Ne pas pulvériser de produit sur la pompe.
Français
© SprayTECH. Tous droits réservés. 15
Consignes de sécurite important · Lire toutes ces consignes avant
d’utiliser l’appareil. GARDER CES CONSIGNES.
DANGER : EXPLOSION CAUSÉE PAR DES
PRODUITS INCOMPATIBLES
Ce type d’explosion peut entraîner des dommages
matériels ou des blessures graves.
MESURES PRÉVENTIVES :
Ne pas utiliser de produits contenant du chlore ou du javellisant.
Ne pas utiliser de solvants à base de halons comme l’eau de
javel, les agents antimoisissure, le chlorure de méthylène et le
trichloroéthane-1-1-1, lesquels ne sont pas compatibles avec
l’aluminium.
Communiquer avec le fournisseur du produit concerné pour en
connaître la compatibilité avec l’aluminium.
DANGER : GÉNÉRALITÉS
D’autres dangers peuvent entraîner des dommages matériels ou des
blessures graves.
MESURES PRÉVENTIVES :
Lire toutes les directives et consignes de sécurité avant d’utiliser
l’appareil.
Observer tous les codes locaux, provinciaux, d’état et nationaux
régissant la ventilation, la prévention des incendies et le
fonctionnement de l’appareil.
Aux États-Unis, le gouvernement a adopté des normes de
sécurité en vertu de l’Occupational Safety and Health Act
(OSHA). Le cas échéant, on doit les consulter, notamment les
parties 1910 des normes générales et 1926 des normes de
construction.
N’utiliser que les pièces autorisées par le fabricant; les
utilisateurs qui choisiront d’utiliser des composants dont les
caractéristiques techniques et les exigences en matière de
sécurité sont inférieures devront en assumer tous les risques et
responsabilités.
Tous les raccords, les tuyaux et les bouchons de remplissage
doivent être xés solidement en place avant d’utiliser la pompe de
pulvérisation. Toute pièce qui n’est pas xée solidement risque
d’être projetée violemment ou d’entraîner la fuite d’un jet de
liquide à une pression extrêmement élevée, ce qui pourrait causer
des blessures graves.
Avant chaque utilisation, examiner tous les exibles an de
conrmer l’absence de coupures, de fuites, d’abrasions ou
de renements. Vérier également l’intégrité des raccords.
Remplacer sans délai les pièces qui semblent présenter des
défectuosités. Ne jamais tenter de réparer un exible; remplacer
ceux qui font défaut par des modèles haute pression, avec mise à
la terre.
•. Ne faites pas de nouer avec le tuyau et ne le tordez pas trop. Le
tuyau à vide peut présenter des fuites suite à l’usure, les nouer
ou les mauvais traitements. Une fuite risque d’injecter du produit
dans la peau.
•. N’exposez pas le tuyau à des températures ou des pressions
supérieures à celles spéciées par le fabricant.
Ne pas pulvériser à l’extérieur par grands vents.
Porter des vêtements aptes à protéger la peau et les cheveux du
produit utilisé.
Ne pas utiliser le pistolet ou ne pas pulvériser de produits
en présence d’enfants à proximité. Éloigner les enfants de
l’équipement en tout temps.
Ne pas s’étirer ni ne travailler sur un support instable. Toujours
garder les deux pieds au sol pour rester en équilibre.
Se servir de la pression la plus basse possible pour vidanger
l’appareil.
Rester vigilant et faire attention à ce que l’on fait.
Ne pas se servir de l’équipement en cas de fatigue ou si vos
aptitudes sont affaiblies par la consommation de drogues ou de
boissons alcoolisées.
Pour les appareils électriques — Débranchez toujours le cordon
électrique de la prise avant de travailler sur l’équipement.
N’utilisez pas le tuyau pour tirer ou soulever l’équipement.
Ne pas soulever par la poignée de chariot en chargeant ou en
déchargeant.
Instructions de mise à la terre
Cet appareil doit être mis à la terre. La mise à la terre réduit les risques
d’électrocution lors d’un court-circuit en permettant au courant de
s’écouler par le l de mise à la terre. Cet appareil est muni d’un cordon
électrique avec l de mise à la terre ainsi que d’une che de terre. La
che doit être branchée sur une prise installée correctement et mise à la
terre conformément à la réglementation et aux codes en vigueur.
MISE EN GARDE - Le fait de ne pas brancher
correctement la fiche trifilaire de l’appareil peut entraîner
des risques de choc électrique.
Si on doit réparer ou remplacer le cordon ou la che, ne pas
raccorder le l de terre à la borne des broches plates (lames) de cette
dernière. Ce l, normalement vert (avec ou sans rayures jaunes), doit
être relié à la broche de terre.
Consulter un technicien ou un électricien qualié à défaut de comprendre
l’ensemble des présentes directives ou en cas d’incertitude quant à la
mise à terre de l’appareil. Ne pas modier la che de l’appareil; si elle ne
s’adapte pas dans la prise voulue, faire remplacer cette dernière par un
électricien qualié.
Prise trifilaire
Broche de mise à la terre
Plaque murale de la prise
IMPORTANT : Utiliser uniquement une rallonge à trois fils
munie d’une fiche de terre dans une prise secteur mise à la terre
correspondant au type de fiche de l’appareil. S’assurer que votre
rallonge est en bon état. Lorsque vous utilisez une rallonge,
assurez-vous qu’elle soit d’un calibre suffisant pour supporter
l’intensité du courant requise par l’appareil. Une rallonge trop
mince entraîne une chute de tension, une diminution de l’intensité
et une surchauffe. Une rallonge de calibre 12 est recommandée.
Si vous devez utiliser une rallonge à l’extérieur, celle-ci doit
comprendre la marque W-A après la désignation indiquant le type
de cordon. Par exemple, la désignation SJTW-A indique que le
cordon est conçu pour être utilisé à l’extérieur.
Español
16 © SprayTECH. Todos los derechos reservados.
Información de seguridad importante · Lea toda la información de
seguridad antes de operar el equipo. GUARDE ESTAS INSTRUCCIONES.
Indica una situación peligrosa que, de no evitarse, puede
causar la muerte o lesiones graves.
Para reducir los riesgos de incendios, explosiones,
descargas eléctricas o lesiones a las personas, lea y
entienda todas las instrucciones incluidas en este
manual. Familiarícese con los controles y el uso
adecuado del equipo.
PELIGRO: LESIÓN POR INYECCIÓN
El ujo de pintura a alta presión que produce este
equipo puede perforar la piel y los tejidos subyacentes,
ocasionando lesiones graves y posible amputación.
CONSULTE A UN MÉDICO INMEDIATAMENTE.
¡NO TRATE LA LESIÓN POR INYECCIÓN COMO UNA
CORTADURA SIMPLE! La inyección puede ocasionar amputación.
Consulte a un médico inmediatamente.
La gama operativa máxima de la pistola es de 3100 PSI / 21,4 MPa de
presión del líquido.
PREVENCIÓN:
NUNCA apunte la pistola a ninguna parte del cuerpo.
No apunte con la pistola ni rocíe a cualquier persona o animal.
NUNCA deje que ninguna parte del cuerpo toque el ujo de
líquido. NO deje que el cuerpo toque una fuga de la manguera de
líquido.
NUNCA ponga la mano frente a la pistola. Los guantes no
protegen contra una lesión por inyección.
SIEMPRE ponga el seguro del gatillo, apague la bomba y
libere toda la presión antes de dar servicio, limpiar la boquilla o
protección, cambiar la boquilla o dejar la pistola sin supervisión.
No se libera la presión al apagar el motor. Debe girarse la perilla
PRIME/ SPRAY (CEBAR/ROCIAR) a PRIME (CEBAR) para
aliviar la presión. Consulte el PROCEDIMIENTO PARA ALIVIAR
LA PRESIÓN descrito en este manual.
SIEMPRE mantenga la protección de la boquilla en su sitio
al rociar. La protección de la boquilla sirve principalmente de
dispositivo de advertencia.
SIEMPRE retire la boquilla rociadora antes de enjuagar o limpiar
el sistema.
La manguera de pintura puede presentar fugas por desgaste,
dobleces y maltrato. La fuga puede inyectar material traspasando
la piel. Inspeccione la manguera antes de cada uso. No use
mangueras para levantar o tirar del equipo.
NUNCA use una pistola rociadora sin contar con el seguro y la
protección del gatillo.
Todos los accesorios deben tener capacidades nominales de
3100 PSI / 21,4 MPa como mínimo. Esto incluye las boquillas
rociadoras, pistolas, extensiones y manguera.
No deje el aparato con corriente ni con presión cuando nadie esté
pendiente de ella. Cuando no utilice el aparato, apáguelo y libere
la presión siguiendo las instrucciones del PROCEDIMIENTO
PARA ALIVIAR LA PRESIÓN descrito en este manual.
Antes de utilizar el aparato, verique que todas las conexiones
son seguras. Las partes no aseguradas pueden ser expulsadas
con gran fuerza o ltrar uido a alta presión y provocar lesiones
severas.
Ponga siempre el seguro del gatillo cuando no esté pulverizando.
Verique que el seguro del gatillo funciona correctamente.
NOTA PARA EL MÉDICO:
La inyección a través de la piel es una lesión traumática. Es
importante tratar la lesión tan pronto sea posible. NO retrase
el tratamiento para investigar la toxicidad. La toxicidad es
un factor a considerar con ciertos revestimientos inyectados
directamente en la corriente sanguínea. Puede ser aconsejable
consultar con un cirujano plástico o un cirujano especialista en
reconstrucción de las manos.
PELIGRO: VAPORES PELIGROSOS
Las pinturas, solventes, insecticidas y demás materiales
pueden ser nocivos si se inhalan o toman contacto con
el cuerpo. Los vapores pueden causar náuseas graves,
desmayos o envenamiento.
PREVENCIÓN:
Use un respirador o mascarilla si pueden
inhalarse los vapores. Lea todas las instrucciones
suministradas con la mascarilla para revisar que
brinde la protección necesaria.
Use lentes protectores.
Use ropa protectora según lo indique el fabricante del
revestimiento.
PELIGRO: EXPLOSIÓN O INCENDIO
Los vapores de solventes y pinturas pueden explotar o
inamarse. Pueden producirse daños materiales, lesiones
graves o ambos.
PREVENCIÓN:
Cuente con escape y entrada de aire fresco para mantener el aire
dentro de la zona de aplicación sin acumulaciones de vapores
inamables. Los gases producidos por solventes o pinturas
pueden causar explosiones o incendios.
No rocíe en lugares cerrados.
Evite todas las fuentes de ignición como las chispas de
electricidad estática, las llamas expuestas, appliances
electricidad, las luces piloto y los objetos calientes. La conexión o
desconexión de cables eléctricos o interruptores de luz operativos
puede producir chispas. Si la pintura o el solvente uyen por el
equipo se puede generar electricidad estática.
No fume en el área de aplicación.
Debe haber un extintor de incendios en buen estado.
Coloque la bomba de pintura a un mínimo de 7.62 meters (25
pies) del objeto a pintar dentro de un área bien ventilada (añada
más manguera si es necesario). Los vapores inamables son
generalmente más pesados que el aire. El área debe estar
sumamente bien ventilada.
El equipo y los objetos dentro y alrededor del área a pintar deben
estar debidamente conectados a tierra para evitar las chispas de
estática.
Mantenga el área limpia y libre de contenedores de pintura o
solvente, trapos y otros materiales inamables.
Use solamente una manguera conductora o conectada a tierra
para líquidos a alta presión. La pistola debe conectarse a tierra a
través de las conexiones de la manguera.
Para las aparatos eléctricas — Debe conectarse el cable eléctrico
a un circuito a tierra.
Siempre enjuague la unidad dentro de un recipiente metálico
separado, con la bomba a baja presión y habiendo sacado la
boquilla rociadora. Sostenga la pistola rmemente contra el
costado del recipiente para conectar a tierra el mismo y evitar
chispas de estática.
Siga las advertencias e instrucciones del fabricante del material
y del solvente. Conozca los contenidos de las pinturas y los
solventes con los que rocía. Lea todas las Hojas de Datos sobre
Seguridad de Materiales (MSDS) y las etiquetas del contenedor
provistas con las pinturas y los solventes. Siga las instrucciones
de seguridad del fabricante de pinturas o solventes.
Tenga muchísmo cuidado al usar materiales cuyo punto de
ignición sea inferior a 70°F (21°C). El punto de inamación es la
temperatura a la que un uido puede producir vapores sucientes
para encenderse.
El plástico puede causar chispas de estática. Nunca cuelgue
plásticos para cerrar una zona a pintar. No use mantas plásticas
al aplicar materiales inamables.
Use la presión más baja posible para enjuagar el equipo.
No rocíe el ensamblaje de la bomba.
Español
© SprayTECH. Todos los derechos reservados. 17
Información de seguridad importante · Lea toda la información de
seguridad antes de operar el equipo. GUARDE ESTAS INSTRUCCIONES.
PELIGRO: POSIBLE EXPLOSIÓN DEBIDO A
MATERIALES INCOMPATIBLES
Causará daños materiales o lesiones graves.
PREVENCIÓN:
No use materiales que contengan blanqueador o
cloro.
No use solventes de hidrocarburos halogenados como
blanqueador, mohocida, cloruro de metileno y 1,1,1 tricloroetano.
No son compatibles con el aluminio.
Diríjase al proveedor de revestimientos para obtener los datos de
compatibilidad del material con el aluminio.
PELIGRO: GENERAL
Puede causar daños materiales o lesiones graves.
PREVENCIÓN:
Lea todas las instrucciones y las precauciones de seguridad
antes de operar el equipo.
Siga todos los códigos locales, estatales y nacionales
correspondientes que rijan la ventilación, prevención de incendios
y operación.
Se han adoptado las normas de seguridad del Gobierno de los
Estados Unidos según la Ley de seguridad ocupacional y salud
(Occupational Safety and Health Act, OSHA). Deben consultarse
estas normas, particularmente el apartado 1910 de las Normas
generales y el apartado 1926 de las Normas de construcción.
Utilice solamente componentes autorizados por el fabricante.
El usuario asume todo riesgo y responsabilidad al utilizar
componentes que no cumplan con las especicaciones mínimas
y requisitos de seguridad del fabricante de la bomba.
Todos los acopladores, las mangueras y las tapas de los ltros
deben estar asegurados antes de operar la bomba de rocío. Las
partes no aseguradas pueden ser expulsadas con gran fuerza o
ltrar uido a alta presión y provocar lesiones severas.
Antes de cada uso, revise todas las mangueras en busca de
cortes, fugas, abrasión o hinchazón de la cubierta. Revise
si hay daños o movimiento de los acoplamiento. Cambie
inmediatamente la manguera si existe alguna de estas
condiciones. Nunca repare una manguera de pintura. Cámbiela
por otra manguera conectada a tierra apta para alta presión.
No retuerza ni doble la manguera en exceso. En la manguera
airless pueden aparecer fugas a causa del desgaste, de
retorcimientos o de un mal uso. Una fuga puede inyectar material
en la piel.
No exponga la manguera a temperaturas o presiones que
superen las especicadas por el fabricante.
No pinte en exteriores en días con viento.
Use ropa que mantenga la pintura alejada de la piel y el cabello.
No lo opere ni rocíe cerca de los niños. Mantenga a los niños
alejados del equipo en todo momento.
No se asome ni se pare sobre soportes inestables. Mantenga
siempre la posición rme y el equilibrio efectivos.
Use la presión más baja posible para enjuagar el equipo.
Manténgase alerta y mire lo que hace.
No utilice la unidad cuando se encuentre cansado o bajo la
inuencia de las drogas o el alcohol.
Para las aparatos eléctricas — Desenchufe siempre el cable
antes de trabajar en el equipo.
No utilice la manguera como elemento de fuerza para tirar del
equipo o levantarlo.
No levantar por la manija del carro al cargar o descargando.
Instrucciones para conectar a tierra
Este producto se debe conectar a tierra. En caso de que ocurra un
corto circuito, la conexión a tierra reduce el riesgo de choque eléctrico
al proporcionar un alambre de escape para la corriente eléctrica. Este
producto está equipado con un cable que tiene un alambre de conexión a
tierra con un enchufe de conexión a tierra apropiado. El enchufe se debe
enchufar en una toma de corriente que se haya instalado y conectado a
tierra debidamente, de acuerdo con todos los códigos y estatutos locales.
ADVERTENCIA - La instalación incorrecta del enchufe a
tierra puede ocasionar un riesgo de choque eléctrico.
Si es necesario reparar o cambiar el cable o el enchufe, no
conecte el cable verde a tierra a ninguno de las terminales de espiga
plana. El cable con aislamiento de color verde por fuera con o sin rayas
amarillas es el alambre a tierra y debe conectarse a la espiga a tierra.
Consulte a un electricista o técnico de servicio capacitado si las
instrucciones para la conexión a tierra no se entienden claramente o si
tiene dudas en cuanto a que el producto esté debidamente conectado a
tierra. No modifique el enchufe que se incluye. Si el enchufe no encaja
en el receptáculo, pida a un electricistas capacitado que instale un
receptáculo adecuado.
Receptáculo conectado a tierra
Pata a tierra
Tapa de la caja de receptáculo conectada a tierra
IMPORTANTE: Use solamente extensiones trifilares que tengan un
enchufe de conexión a tierra de 3 hojas y un receptáculo de triple
ranura que acepte el enchufe del producto. Asegúrese de que su
extensión esté en buenas condiciones. Cuando use una extensión,
asegúrese de usar una que sea lo suficientemente resistente como
para soportar la corriente que descargue su producto. Un cable de
un tamaño menor causará una caída de voltage en la línea que dará
como resultado una pérdida de energía y un sobrecalenta|ôento. Se
recomienda usar un cable de calibre 12. Si se utiliza un cable de
extensión en el exterior, tiene que estar marcado con el sufijo W-A
después de la designación del tipo de cable. Por ejemplo, SJTW-A
para indicar que el cable es apropiado para uso en exteriores.
18 © SprayTECH. All rights reserved.
Parts List
Main Assembly
1
2
3
10
11
12
6
5
4
7
8
9
13
15
14
16
10
11
Item Part # Description Quantity
1 0552185A Upright cart assembly ...............................1
2 0507784 Grommet ...................................................2
3 ---------- Drive assembly .........................................1
4 0508343 Fitting ........................................................1
5 0507773 Jam nut .....................................................1
6 0552155A Fluid section assembly ............................1
7 0507798 Siphon tube ..............................................1
8 0507783 Hose clamp ...............................................1
9 5006536 Inlet screen ...............................................1
Item Part # Description Quantity
10 51357 Lock washer .............................................5
11 0507957 Screw ........................................................5
12 0507785 Return hose w/tting .................................1
13 0552240A Filter assembly .........................................1
14 0507690 PRIME/SPRAY valve assembly ...............1
15 5000527 Outlet tting ..............................................1
16 0507671 Fitting ........................................................1
17 0507387 Hose (not shown) .....................................1
© SprayTECH. All rights reserved. 19
Drive Assembly
30
1
3
5
4
6
7
8
9
10
11
12
14
15
16
17
13
2
36
37
19
20
18
21
22
23
24
25
27
28
29
26
31
32
34
33
35
Item Part # Description Quantity
1 0507959 Electronic cover ........................................1
2 0507960 Screw ........................................................3
3 0551775 Motor assembly ........................................1
4 0507230 Front end bell assembly ...........................1
5 0507776 Housing gasket .........................................1
6 0507221 1st stage gear assembly...........................1
7 0507222 2nd stage gear assembly .........................1
8 0507219 Front gearbox assembly ...........................1
9 0507218 Slider assembly ........................................1
10 0507769 Slider housing ...........................................1
11 0507767 Screw ........................................................4
12 0552316 Front cover ...............................................1
13 0507799 Screw ........................................................4
14 0507768 Retaining ring ...........................................1
15 0507777 Connecting pin..........................................1
16 0507760 Screw ........................................................2
17 0507754 Relay ........................................................1
18 9800340 Screw ........................................................1
19 0551624 Mounting plate ..........................................1
20 0507757 Grommet ...................................................1
Item Part # Description Quantity
21 0551628 Fuse holder...............................................1
22 0551627 Fuse ..........................................................1
23 0507756 Screw ........................................................1
24 0507752 Potentiometer mounting plate...................1
25 0507749 Nut ............................................................1
26 0507748 Cap ...........................................................1
27 0507740 Pressure control knob...............................1
28 0507759 Potentiometer ...........................................1
29 806-213 Power cord ...............................................1
30 0507770 Screw ........................................................3
31 0295694 Lock washer .............................................3
32 0551626 Electronic control assembly ......................1
33 0507231 Fan shroud ...............................................1
34 0507225 Fan assembly ...........................................1
35 0507762 Bafe assembly ........................................1
36 0507771 Screw ........................................................4
37 0552312 Motor shroud ............................................1
38 0507961 Wire cover, 7” (not shown) .......................1
39 0507962 Wire assembly (not shown) ......................1
40 0551972 Surge suppressor (not shown) .................1
41 0551260 Wire assembly (not shown) ......................1
NOTE: All electrical work should be performed by a
SprayTECH authorized service center.
20 © SprayTECH. All rights reserved.
Fluid Section Assembly (P/N 0552155)
Item Part # Description Quantity
1 0508707 Upper seal retainer ...................................1
2 0508708 Upper support ring ....................................1
3 0552177 Upper packing assembly ..........................3
4 0552156 Cylinder ....................................................1
5 0552178 Lower packing assembly ..........................2
6 0552157 Adapter .....................................................1
7 0507732 Piston rod .................................................1
8 0507734 Outlet valve seal .......................................1
9 0507452 Outlet valve cage ......................................1
10 0507454 Washer, nylon ...........................................1
11 9841502 Outlet valve ball ........................................1
12 0294516 Outlet valve seat .......................................1
13 0507733 Outlet valve retainer .................................1
14 0507729 Inlet valve cage.........................................1
15 51519 Inlet valve ball ...........................................1
16 00310 Inlet valve seat..........................................1
17 00203 O-ring ........................................................1
18 0507730 O-ring, Viton .............................................2
19 0507731 Back-up ring, PTFE .................................2
20 0507728 Inlet valve housing ....................................1
21 0507229 Piston assembly (includes items 7–13) ....1
0551687 Repacking kit (includes items 3, 5, 6,
8, 10, 11, 15, and 17–19)
0552150 Lower packing insertion tool
1
7
8
5
6
2
3
4
Install upper packing
with raised lip
facing down.
9
10
11
12
13
14
15
16
17
18
19
20
21
Raised Lip
Large Beveled Edge
Install lower packing so
large beveled edge will
be facing up when the
cylinder is upright.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Titan Advantage™ EXP2455 Le manuel du propriétaire

Catégorie
Pulvérisateur de peinture
Taper
Le manuel du propriétaire
Ce manuel convient également à