Page 50
Performance Data Sheet
Pure H2O
-In U.S.-Watts Regulator Co., N. Andover, MA 01845 (Watts.com)
-In Canada-Watts, Water Technologies (Canada), Inc. Toronto, ON M5J3G6 (Watts.ca)
3-Stage Reverse Osmosis System - H2O-DWRO300
Recommended Replacement Parts and Change Interval
Note: Depending on incoming feed water conditions replacement time frame may vary.
Description Model / Part Number
Intervalle de
remplacement
Carbon Block Filter H2O-F12 / 88005217
6 mois ou 2 000 gallons
(7 570,824 litres)
Reverse Osmosis
Membrane
H2O-F16 / 88005218 2 à 5 ans
Granular Activated Carbon
Filter
H2O-F17 / 88005219
12 mois ou 2 000 gallons
(7 570,824 litres)
Eff. moy. (mg/l) In. moy. (mg/l) % réduction pH Pression Eff. max. mg/l Concentration inf. mg/l Max. admissible mg/l
Arsenic (Pentavalent) 0,310 0,001 99,6 % 7,24 50 lb/po² 0,002 0,30±10 % 0,010 mg/l
Réduction du baryum 9,2 0,08 99,0 % 7,64 50 lb/po² 0,12 10,0±10 % 2,0
Réduction du cadmium 0.031 0,0004 98,0 % 7,49 50 lb/po² 0,0008 0,03±10 % 0005
Chlore 2,05 0,03 97,0 % 7,0 à 8,0 S.O. 2,4 2,0 mg/l ± 10 % 2,2 (8,3)
Chrome (Hexavalent) 0,30 0,002 99,0 % 7,24 50 lb/po² 0,004 0,03±10 % 0,1
Chrome (Trivalent) 0,30 0,001 99,0 % 7,64 50 lb/po² 0,002 0,03±10 % 0,1
Réduction du cuivre 3,2 0,02 99,0 % 7,40 50 lb/po² 0,04 3,0±10 % 1,3
Kystes 92 000/ml 3/ml 99,99 % 7,44 50 lb/po² 18 minimum 50 000/ml S.O.
Réduction du fluorure 8,7 0,19 97,0 % 7,24 50 lb/po² 0,3 8,0±10 % 1,5
Réduction du plomb 0,15 0,002 98,8 % 7,39 50 lb/po² 0,005 0,15±10 % 0,0107
Radium 226/228 25 pCi/L 5 pCi/l 80,0 % 7,24 50 lb/po² 5 pCi/l 25 pCi/L±10 % 5 pCi/l
Sélénium 94,85 <0,2 97,0 % 7,24 50 lb/po² <0,2 0,10±10 % 0,05
MDT 770 35 95,0 % 7,28 50 lb/po² 26,0 750±40 mg/l 187
Turbidité 11,3 0,1 99,0 % 7,43 50 lb/po² 0 à 1 11±1 mg/l 0,5 NTU
Turbidité 11,3 0,1 99,0 % 7,43 50 lb/po² 0 à 1 11±1 mg/l 0,5 NTU
Récupération - 22 % par jour Taux de production - 20,5 gal/jour Efficacité - 10,5 %
GENERAL USE CONDITIONS
1. System to be used with municipal or well water sources
treated and tested on regular basis to insure bacteriological
safe quality. DO NOT use with water that is microbiologically
unsafe or unknown quality without adequate disinfection
before and after the system. Systems certified for cyst
reduction may be used on disinfected water that may contain
filterable cysts.
2: Température de fonctionnement : Maximum : 100 °F
(37.7 °C) minimum 40 °F (4.4 °C)
3: Operating Water Pressure: Maximum 100-psi (690 kPa)
Minimum: 35 psi (341 kPa)
4. pH 2 to 11
5. Maximum Iron present in incoming water supply must be less
than 0.2 ppm.
6. Hardness of more than 10 grains per gallon (170 ppm) may
reduce RO membrane life expectancy.
7. Recommend TDS (Total Dissolved Solids) not to exceed
1800 ppm.
This system has been tested according to NSF/ANSI 58 for reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the
system as specified in NSF/ANSI 58 and 42. This system has been tested for the treatment of water containing pentavalent arsenic (also
known as As (V), As (+5), or arsenate) at concentrations of 0.30 mg/L or less. This system reduces pentavalent arsenic, but may not
remove other forms of arsenic. This system is to be used on water supplies containing a detectable free chlorine residual at the system
inlet or on water supplies that have been demonstrated to contain only pentavalent arsenic. Treatment with chloramine (combined
chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic, Please see the Arsenic Facts section
of the Performance Data Sheet for further information.
Bien que les tests ont été réalisés en conditions standard de laboratoire, les performances réelles peuvent varier. En fonction de la
composition chimique de l’eau, de la température de l’eau et de la pression de l’eau, la production et la performance des systèmes
peuvent varier. La valeur d’efficacité désigne le pourcentage d’eau entrant dans le système dont le consommateur dispose sous forme
d’eau traitée par osmose inverse dans des conditions de fonctionnement d’utilisation quotidienne générale approximatives. La valeur
de récupération désigne le pourcentage d’eau entrant dans la membrane du système dont le consommateur dispose sous forme d’eau
traitée par osmose inverse quand le système fonctionne sans réservoir de stockage ou quand le réservoir de stockage est contourné.
En moyenne, 4 litres d’eau sont rejetés pour chaque litre d’eau produite.