GE Water Dispenser PXRQ15F Manuel utilisateur

Taper
Manuel utilisateur

Ce manuel convient également à

ge.com
Reverse Osmosis
101019-A 215C1174P003 49-50198 01-06 JR
Filtration System
PXRQ15F
PNRQ15FBL
Owner’s Manual
and Installation
Safety Instructions
Safety Instructions . . . . . . . . . . . . . .2
Specification Guidelines . . . . . . . . .3
Operating Instructions
About the RO System . . . . . . . . .4, 5
Installation Instructions
Tools and Materials Required . . . . .6
Before Beginning Installation . . .6, 7
Mounting System Installation . . . . .8
Feed Water Supply . . . . . . . . . . .9–12
Faucet Assembly . . . . . . . . . . . .13, 14
Battery Installation . . . . . . . . . . . .14
Filtration Drain Connection . .15, 16
Storage Tank and Startup . . . . . . .17
Care and Cleaning
Prefilter, Postfilter and
RO Cartridge Replacement . . . . . .18
Sanitization . . . . . . . . . . . . . . . . . .19
Water Test Kit . . . . . . . . . . . . . . . .20
Troubleshooting Tips . . . . . .21, 22
Consumer Support
Consumer Support . . . . .Back Cover
Parts List/Catalog . . . . . . . . . .24, 25
Warranty . . . . . . . . . . . . . . . . . . . .26
Manuel d’utilisation
et d’installation
Manual del propietario
y instalación
La section française commence à la page 27
Osmose Inversée
Système de Filtration
La sección en español empieza en la página 55
Ósmosis Inversa
Sistema de Filtración
Tested and Certified by NSF International to
NSF/ANSI Standard 58. For the reduction of the
claims specified, see the Performance Data Sheet.
Essayé et certifié par NSF International
conformément aux normes 58 NSF/ANSI. Pour
la réduction des caractéristiques indiquées,
consultez la feuille de données de rendement.
Probado y certificado por NSF International por
cumplir con el estándar 58. Para la reducción de
reclamos especificados, ver la hoja de datos de
desempeño.
Write the model and serial
numbers here:
Model # __________________
Serial # __________________
You can find them on the bracket.
IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING.
Check with your state and local public works
department for plumbing and sanitation codes.
You must follow these guidelines as you install the
Reverse Osmosis system. Using a qualified installer
is recommended.
If house water pressure is over the maximum
(120 pounds per square inch), install a pressure
reducing valve in the water supply line to the
Reverse Osmosis system.
Be sure the water supply conforms with the
Specification Guidelines. If the water supply conditions
are unknown, contact your municipal water company
or your local health department for a list of
contaminants in your area and a list of laboratories
certified by your state to analyze drinking water.
WARNING: Before using the Reverse Osmosis
system for the first time, the system must be
purged. The Reverse Osmosis cartridge contains
a food grade preservative that must be purged
from the system. The preservative will give product
water an unpleasant taste and odor.
WARNING: Do not use with water that is
microbiologically unsafe or of unknown quality
without adequate disinfection before or after the
system. Systems certified for cyst reduction may
be used on disinfected water that may contain
filterable cysts.
This system has been tested for the treatment of
water containing pentavalent arsenic (also known
as As(V), As(+5) or arsenate) at concentrations
of 0.050 mg/L or less. This system reduces
pentavalent arsenic, but may not remove other
forms of arsenic. This system is to be used on water
supplies containing a detectable free chlorine
residual or on water supplies that have been
demonstrated to contain only pentavalent arsenic.
Treatment with chloramine (combined chlorine)
is not
sufficient to ensure complete conversion of
trivalent arsenic to pentavalent arsenic. Please see
the Arsenic Facts section of the Performance Data
Sheet for further information.
This reverse osmosis system contains a replaceable
component critical to efficiency of the system.
Replacement of the reverse osmosis component
should be with one of identical specifications, as
defined by the manufacturer, to assure the same
efficiency and contaminant reduction performance.
SAVE THESE INSTRUCTIONS
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
Install or store where it will not be exposed to
temperatures below freezing or exposed to any type
of weather. Water freezing in the system will
damage it. Do not attempt to treat water over 100°F.
Do not install on HOT WATER. The temperature
of the water supply to the Reverse Osmosis system
must be between the minimum of 40°F and the
maximum of 100°F. See the Specification Guidelines.
Extended non-use of the Reverse Osmosis system.
If the system has not been used for one week or
more, open the RO water faucet and allow the
system to drain. Close the RO water faucet and
allow the system to regenerate the water supply.
Recommended installation is under the sink.
However, the unit can be installed in a remote
location, up to 20 feet away from the sink.
However, additional materials will be required.
See parts list to obtain additional materials
from GE.
Locating the tank on a basement floor, with the
faucet at a first floor sink may result in some loss
of flow rate and capacity (approximately 20%).
Installing a second tank will improve this
performance. An RVKIT can be used.
If Reverse Osmosis system is connected to a
refrigerator icemaker, a special icemaker
connection kit is required (RVKIT). Do not use
copper tubing for the connection between the
Reverse Osmosis system and the refrigerator.
WARNING: Discard all unused parts and packaging
material after installation. Small parts remaining after
the installation could be a choke hazard.
Sanitize upon installation of the Reverse Osmosis
system and after servicing inner parts, including
replacement of prefilter, postfilter and Reverse
Osmosis cartridge. It is important to have clean
hands while handling inner parts of the system.
See the Sanitizing the Reverse Osmosis System section.
This Reverse Osmosis system contains a replaceable
treatment component critical for effective
reduction of total dissolved solids. This product
water shall be tested periodically to verify that the
system is performing satisfactorily. See the About
the Water Test Kit section.
BE SURE TO FOLLOW ALL APPLICABLE STATE
AND LOCAL CODES.
WARNING!
For your safety, the information in this manual must be followed to minimize the risk of
property damage or personal injury.
SAFETY PRECAUTIONS
PROPER INSTALLATION AND MAINTENANCE
This Reverse Osmosis system must be properly installed and located in accordance with the
Installation
Instructions before it is used.
Consumer Support Troubleshooting Tips
Operating Instructions Safety InstructionsInstallation Instructions
2
Consumer SupportTroubleshooting Tips
Operating Instructions
Safety Instructions
Installation Instructions
Specification guidelines.
ge.com
The system makes a good supply of drinking water each day.
How much it will make depends primarily on these things…
Product – height 11 width 10.5 depth 4
Incoming Water pH
WATER SOFTENER RECOMMENDED
INCOMING WATER HARDNESS (GPG)
60
50
40
30
2010
8
6
7
7.5
6.5
Water Softener
not required
Maximum iron, manganese, hydrogen sulfide (ppm) . . . . . . . . . . . . . . . . . . . . . .<0.1
Chlorine in water supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.0 ppm Maximum Allowable
b
Feed water pH limits (pH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–10
Storage tank capacity—gallons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
c
Automatic shutoff control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .yes
Prefilter and postfilter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(FQROPF) Carbon Block
Reverse Osmosis membrane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(FQROMF) Thin Film Polyamide
Storage Tank Dimension (inches) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .height 15” diameter 11”
System Body Dimension (inches) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .height 11” width 10.5” depth 4”
Feed water pressure limits—pounds per square inch (psi) . . . . . . . . . . . . . . . . . . . . . .40–120
a
Feed water temperature limits—minimum/maximum degrees F . . . . . . . . . . . . . . . . .40–100
Maximum Total Dissolved Solids (TDS)—parts per million (ppm) . . . . . . . . . . . . . . . .2000
Maximum water hardness @ 6.9 pH recommended to optimize membrane
life—grains per gallon (gpg) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
For water with hardness greater than 10 grains (at 6.9 pH), the use of a
softener is recommended. Failure to install a water softener will reduce
the life of the Reverse Osmosis membrane. See chart for additional
information on the possible need for a water softener.
a. If house water pressure is over 120 psi, install a pressure reducing valve in the water supply line. If house water pressure
is under 40 psi, install a Reverse Osmosis booster pump (contact your local plumbing supply company).
b. Removed (maximum of 2.0 ppm) by the Reverse Osmosis prefilter. REGULAR MAINTENANCE IS REQUIRED. Chlorine will
destroy the Reverse Osmosis membrane.
c. Theoretical tank capacity. When tested according to NSF/ANSI Standard 58 at 50 psig inlet pressure, tank capacity is
2.3 gallons.
3
4
About the reverse osmosis system.
How the Reverse Osmosis System Works
Description of the Reverse Osmosis System
Reverse Osmosis reduces Total Dissolved Solids (TDS) and organic matter from water by diffusing it through a special
membrane. The membrane separates minerals and impurities from the water and they are flushed to the drain. For the
reduction of the claims specified, see Performance Data Sheet. High quality product water goes directly to the drinking
water faucet or to the storage tank. The system makes a good supply of drinking water each day. How much it makes
depends on the feed water supply pressure, temperature and quality.
The prefilter and postfilter are replaceable cartridges. The carbon prefilter reduces chlorine while also filtering sediments.
The postfilter reduces any other undesirable tastes and odors before you use the water.
The system includes an electronic faucet assembly with a prefilter and postfilter change reminder. When six months have
passed, a flashing blue light will remind you to change the two filters.
Troubleshooting TipsConsumer Support Troubleshooting Tips
Installation Instructions Safety InstructionsOperating Instructions
Prefilter—Water from the cold supply pipe is directed to the
prefilter cartridge. The prefilter is a replaceable sediment
cartridge containing activated carbon. The prefilter reduces
chlorine in the feed water because CHLORINE DESTROYS THE
REVERSE OSMOSIS MEMBRANE. Filtered, clean, chlorine-
reduced water flows from the prefilter to the Reverse
Osmosis cartridge.
Reverse Osmosis Cartridge—The middle cartridge includes a
tightly wound, special membrane. Water is forced through the
cartridge where the membrane reduces the dissolved solids and
organic matter. High quality product water exits the Reverse
Osmosis cartridge and goes to the storage tank. Reject water,
with the dissolved solids and organic matter, leaves the cartridge
and is discharged to the drain through 14tubing.
Postfilter—After leaving the storage area, but before going
to the system faucet, product water goes to the postfilter
cartridge. The postfilter is also a replaceable sediment cartridge
that contains activated carbon. Any remaining tastes, odors or
sediments are reduced from product water by the postfilter.
Clean, high quality drinking water flows through the tubing
and to the system faucet.
Storage Tank—The storage area holds up to 2-1/2 gallons
of product water. A diaphragm inside the tank keeps water
pressurized, when the tank is full, for fast flow to the faucet
when drinking water is needed.
4
3
2
1
5
ge.com
Check Valve—The check valve prevents a backward flow of product water from the storage tank. A backward flow could
cause the Reverse Osmosis membrane to rupture.
Automatic Shutoff Assembly—To conserve water, the drinking water system has an automatic shutoff. When the storage tank
has filled to capacity and the drinking water faucet is closed, pressure closes the shutoff. Water flow to the Reverse Osmosis
housing is shut off until drinking water is used again, and pressure drops in the Reverse Osmosis system.
Flow Control—The flow control regulates the flow of water through the Reverse Osmosis cartridge at the required rate to
produce high quality water. The control is located in the 1/4drain line exiting off the manifold.
Faucet and Electronics—The countertop faucet dispenses filtered drinking water when opened. It has a hand-operated
lever, with variable flow adjustment. You can keep the faucet open by removing your hand from the lever once water is
flowing.
To comply with plumbing codes, an air gap is built into the faucet drain water connection.
8
7
6
5
Consumer SupportTroubleshooting Tips
Operating Instructions
Safety Instructions Installation Instructions
The electronic faucet provides a six month timer to remind you when it is time to replace your prefilter and postfilter.
Replace the filters when the blue light begins to flash in order to protect the RO membrane and keep the system
functioning properly.
Installation
Reverse Osmosis Filtration System
Instructions
Models PXRQ15F and PNRQ15FBL
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com
BEFORE BEGINNING INSTALLATION
Read these instructions completely
and carefully.
IMPORTANT
Save these
instructions for local inspector’s use.
IMPORTANT
Observe all
governing codes and ordinances.
Note to Installer – Be sure to leave these
instructions with the Consumer.
Note to Consumer – Keep these
instructions for future reference.
Proper installation is the responsibility
of the installer.
Product failure due to improper installation
is not covered under the Warranty.
A shutoff valve must be available or added
near the installation point.
TOOLS AND MATERIALS
REQUIRED FOR INSTALLATION
Electric drill and 1-1/4 Drill Bit (type as
required) if mounting is needed for faucet
Two (2) Adjustable Wrenches
1/16 Drill Bit (optional for pilot holes)
Tape Measure
Phillips and Flat Blade Screwdrivers
Utility Knife
If your main water line is a rigid pipe,
you will require a compression fitting
and possibly other plumbing hardware
to complete the installation.
CAUTION: To avoid damaging the
sink, consult a qualified plumber or installer
for drilling procedures. Special drill bits may
be needed for porcelain or stainless steel.
CONTENTS INCLUDED
WITH PRODUCT
Reverse Osmosis Assembly and Tubing
Product Literature (Owner’s Manual and
Installation Instructions)
Performance Data Sheet
Feed Water Adapter and Supply Valve
Faucet Assembly with Electronic Base
Monitor and Tubing
Storage Tank
Drain Line Adapter
6
WARNING:
Read entire manual. Failure to follow all guides and rules could cause
personal injury or property damage.
Check with your state and/or local public works department for plumbing codes. You must
follow their guides as you install the Water Filtration system.
NOTE: Failure to comply with these installation instructions will void the product warranty, and
the installer will be responsible for any service, repair or damages caused thereby.
Installation Instructions
Things to Check Before Beginning Installation
FEED WATER
The water supply to the undercounter Reverse
Osmosis system must have the qualities listed
in the specifications. Municipal water supplies
most often will have these qualities. Well
water may need conditioning—have the water
tested by a water analysis laboratory and get
their recommendations for treatment.
CAUTION: For water with a
hardness greater than 10 grains (at 6.9 pH),
the use of a softener is recommended. Failure
to install a softener will reduce the life of the
Reverse Osmosis cartridge.
FILTRATION DRAIN CONNECTION
A suitable drain point and air gap (check your
state and/or local codes) are needed for reject
water from the Reverse Osmosis membrane
cartridge.
BASEMENT INSTALLATION
If installing in a basement, leave enough
tubing in place during installation to be able
to move unit to floor for ease at servicing and
making filter/membrane changes. Additional
tubing and fittings required.
NOTE: See parts list on page 25 for optional
parts that may be required for a basement
installation.
RO FAUCET
The RO product water faucet installs on the
sink or on the countertop next to the sink.
Often, it is installed in an existing sink spray
attachment hole or a hole may be drilled.
Space is required underneath for tubing to
and from the faucet, and for securing the
faucet in place. All faucet connections are
done on or above the sink or countertop.
Sink
p-trap
Hot Cold
Disposer
1/4 drain
tube (black)
3/8 outlet tube (blue banded)
1/4 inlet tube
(yellow banded)
Reverse osmosis system
3/8 storage
tank tube
(red banded)
11 dia. 10-1/2
15
11
7
3/8 drain tube (black)
RO product water faucet mounted through sink or countertop
Feed water adapter
Prefilter PostfilterMembrane
1/4 yellow
banded inlet
from supply
valve
1/4 black
tube to
faucet
3/8 red
banded tube
to storage
tank
3/8 blue
banded
tube to
faucet
7
TUBING/FILTER DETAIL
Installation Instructions
REVERSE OSMOSIS ASSEMBLY
MOUNTING SYSTEM
INSTALLATION
Choose a location under the sink to mount
the system. Location should be easily
accessible, with adequate clearance between
the bottom of the filter cartridges and the
floor or bottom of the cabinet for removal
of filter cartridges. Allow enough space on
either side of the system for the tubing
connections.
1. Remove the prefilter and postfilter
cartridges.
2. Remove the assembly cover by unlocking
the four tabs on the cover from the system.
3. Use a flat-head screwdriver to work from
left to right from the underside of the
system.
4. Use the icons on the bottom of the
system for screwdriver positioning.
5. Hold the Reverse Osmosis assembly up to
the wall surface where you wish to install
it. Mark location for screws. There should
be a minimum of 17 inches from the
marks to the bottom of the cabinet floor.
CAUTION: Do not get dirt or
debris inside the assembly area. Use only to
mark mounting hole locations.
6. Install screws to the wall, leaving a 3/16-
inch clearance between the head of the
screw and wall (drill pilot holes if needed).
7. Hang the Reverse Osmosis assembly on
the screws. Tighten or loosen the screws
as desired until the system is secure on
the wall.
8. To install the
cover, line up
the front
tabs on the
cover with the
openings
in the system.
9. Snap the cover
in place; the
tabs will flex,
allowing the
cover to snap
in place.
10. Remove the
membrane
cartridge.
Screw locations
17 inches
7 inches
Screws
Screw
3/16
Wall
Screwdriver positioning
ScrewdriverSystem opening
Tab
Prefilter
Postfilter
To removeTo remove
To remove
Membrane
8
Installation Instructions
FEED WATER SUPPLY
A. PREFERRED INSTALLATION
Utilizing existing kitchen sink water supply
valve (A) and removable faucet tubing (B).
1. Refer to illustration below to complete
assembly depending on supply valve
size (A).
2. Close the cold water supply valve (A)
under the sink.
3. Unscrew the flexible tubing line (B) from
the supply valve (A) that connects to the
COLD water riser.
NOTE: For rigid pipe, see C. Optional
Installation on page 10.
Note Adapter (C) orientation:
3/8-inch installation—Rounded end of adapter
(C) connects to supply valve (A).
1/2-inch installation—Rounded end of adapter
(C) connects to coupling (D), then to existing
faucet tubing (B).
Check and comply with local plumbing codes as you plan, then install a cold feed water supply fitting.
4. Assemble adapter (C) and coupling (D)
as shown in illustration at left, per your
configuration. Ensure that the gasket (G)
is in place before final assembly. Start
installation by hand, then finish tightening
with adjustable wrench. Be careful not
to overtighten or cross thread as damage
to threads may occur.
5. Hand tighten assembled adapter (C)
onto supply valve (A) for the proper size
installation. Be sure gasket (G) is in place
before final assembly. Start installation
by hand, then finish tightening with an
adjustable wrench. Be careful not to
overtighten or cross thread as damage
to threads may occur.
6. Reconnect faucet tubing line (B) to top
of adapter (C).
NOTE: If inlet valve (F) is to be removed
for installation, refer to E. Removal and
Reinstallation of Inlet Valve on page 11.
7. Cut wire ties on tubing coils, using care
not to damage tubes or parts if using a
utility knife.
8. Remove the 1/2 nut (I) and ferrule (H)
from end of inlet valve. Using the yellow
banded tubing provided, place the nut (I)
and ferrule (H) onto the tubing and install
onto inlet valve (F) as shown at left.
Tighten with adjustable wrench. Be
careful not to overtighten or cross thread
as damage to threads may occur.
NOTE: Inspect the ends of the tubing prior
to installation to be sure there are no
imperfections and that the end of the tubing
is cut square. It may be necessary to cut
the tubing again.
9
For 3/8 Plumbing For 1/2 Plumbing
(B) Faucet
tubing line (not
included)
(D)
Coupling
(C)
Adapter
(F) Inlet valve
(A) Cold water
supply valve
(not included)
(B) Faucet
tubing line
(not included)
(A) Cold water
supply valve
(not included)
(D)
Coupling
(C)
Adapter
(G) Gasket
(G)
Gasket
(H)
Ferrule
(F) Inlet valve
(I) Nut
(G) Gasket
Installation Instructions
FEED WATER SUPPLY (cont.)
B. OPTIONAL HOME INSTALLATION
Where codes permit (Requires additional parts)
*For 1/2OD or larger metal tubing only.
NOTE: Codes in the state of Massachusetts
require installation by a licensed plumber and
do not permit the use of the saddle valve. For
installation, use plumbing code 248-CMR of the
Commonwealth of Massachusetts.
Saddle valve is available through GE Parts
and Services at 1.800.626.2002, part number
WS15X10023. Self piercing saddle valves are
not recommended.
1. Turn off the cold water supply and attach
saddle valve as required by product
selection. (Be sure to follow manufacturers’
Installation Instructions).
DANGER: Many homes are
electrically grounded through the plumbing.
To protect yourself from serious injury or
fatal shock, use a battery-powered hand drill
only to make the hole. DO NOT USE AN
ELECTRIC DRILL.
2. Close the water supply valve by turning
the handle clockwise.
3. Open the main water supply valve and
several house faucets to purge air from
the system. Close faucets when water
runs smoothly.
Snug valve into bracket
(DO NOT OVERTIGHTEN)
Some threads
should be visible
Rubber gasket
Optional water supply connection (using saddle valve)*
Pre-drill
1/4hole
Seal—make sure
the seal is in place
Clamp X
Nut (2)—not
required if holes
in clamp are
threaded
Valve
Handle
Tubing adapter
Washer
Compression
nut
Clamp Z
Use to connect the tubing
*For 1/2 OD or larger metal tubing only.
C. OPTIONAL RIGID PIPE
INSTALLATION
For installation with rigid pipe between supply
valve and sink faucet.
Option 1
1. Remove pipe from supply valve and sink
faucet.
2. Obtain flexible pipe sized to your
plumbing.
3. Install flexible pipe.
4. GO back to A. Preferred Installation
section, step 4.
Option 2
1. Obtain compression fittings to fit rigid
pipe.
2. Obtain any other fittings required to
connect compression fittings to adapter.
NOTE: Adapter has 1/2-inch and 3/8-inch
internal and external threads.
3. Remove pipe from supply valve.
4. Cut pipe to fit length of assembled fittings
and adapter.
5. Install compression fitting to pipe.
6. GO back to A. Preferred Installation
section, step 4.
NOTE: Above described materials are not
included with the product.
10
Installation Instructions
D. OPTIONAL REMOTE LOCATION
INSTALLATION
(requires additional part)
1. Turn off the cold water supply.
2. Complying with plumbing codes, install a
fitting on the cold water pipe to adapt 1/4
OD tubing. A typical connection is shown
in illustration below. Make sure a water
supply valve is used.
3. If the RO unit is to be installed more than
6 feet from the valve, replace the yellow
banded inlet tubing with a longer length
of GE 1/4 tubing. A 33 foot length of 1/4
tubing is available through GE Parts and
Services at 1.800.626.2002, part number
WS07X10018. DO NOT SUBSTITUTE
TUBING OF UNKNOWN QUALITY.
4. If the RO unit is to be installed more than
6 feet from the faucet, replace the blue
banded outlet tubing with a longer length
of GE 3/8tubing. A 33 foot length is
available through GE Parts and Services at
1.800.626.2002, part number WS07X10019.
See Faucet Installation on page 13 for more
details. DO NOT SUBSTITUTE TUBING OF
UNKNOWN QUALITY.
If you are using copper tubing, DO NOT
connect it directly onto the RO unit. Purchase a
connector and use a short length of the yellow
banded tubing provided to make final connection
to RO. Do not use copper tubing to attach to
icemaker or faucet.
Insert (not included)
Cold
water
pipe
1/4(yellow banded)
tubing to inlet
Ferrule
Water supply valve
To RO
Preferred water supply connection
(using compression fitting)
E. REMOVAL AND RE-INSTALLATION
OF INLET VALVE
(required only if
inlet valve needs to be removed to
complete Step 5 on page 13)
1. Remove inlet valve (F) from adapter (C)
using adjustable wrench on valve body.
See illustration below for detail. DO NOT
USE WRENCH ON HEX NUT END OF
VALVE AS LEAK MAY OCCUR.
2. Remove all sealing tape from inlet valve
(F) and adapter (C) threads.
3. Hand tighten assembled adapter (C)
onto supply valve (A) for the proper size
installation. Be sure the gaskets (G), as
shown on page 13, are in place before
final assembly. Finish tightening with
adjustable wrench. Be careful not to
overtighten or cross thread as damage
to threads may occur.
4. Using white thread sealing tape provided,
apply approximately 9 wraps of tape
around the large threads on inlet valve (F)
in a clockwise direction, as shown below.
5. Hand tighten inlet valve (F) into the adapter
(C), then finish tightening with adjustable
wrench. DO NOT USE WRENCH ON HEX
NUT END OF VALVE AS LEAK MAY OCCUR.
11
(C)
Adapter
(F) Inlet valve
Installation Instructions
INSTALLING THE TUBING TO TANK
AND FAUCET
1. Measure 3/4 from the end of each
remaining piece of tubing (faucet end and
inlet end) and mark with a pencil. (Check
for roundness, smoothness, cuts, nicks,
flat spots and sharp edges).
2. Push the tubing firmly into each fitting on
the manifold until the line is flush with the
fitting collar. (If the tubing is removed, re-
cut the end, measure, mark and re-insert).
Tubing must be fully inserted to avoid
leaks. To remove tubing: depress and hold
red or blue collet; pull tubing out to remove.
3. Pull out slightly on tubing to ensure a
good seal.
3/4
(19 mm)
INCORRECT
3
4
"
Engagement
3/4
(3/8tubing)
Red or Blue Collet
(DO NOT REMOVE)
Insertion line
Insert tubing
FLOW RESTRICTOR
REPLACEMENT PROCEDURE
(cont.)
1. Remove drain line tubing by pushing up
on the drain line collet with one hand (1)
and removing the drain line with the
other hand (2).
2. Once the drain line has been removed
from the system base, grasp the end of
the flow restrictor and pull it straight out
from the tube*. If the restrictor is difficult
to remove by hand, a pair of pliers may
be used to grip the end of the restrictor
to aid in removal from the tubing.
*In some instances, the restrictor may slide out of the
drain tubing as it is removed from the drain line port.
If, after removing the drain line as described in step 1,
the restrictor is no longer in the end of the tubing,
check the drain line port. Remove the restrictor from
the port and proceed to step 3.
3. Take new restrictor and slide it back into the
drain tubing. Insert the restrictor by hand
only. Do not use pliers to insert. Make sure
to insert restrictor all the way into the
tubing. Failure to do so could result in
improper operation of the RO system.
4. Reinsert drain line tubing in system base.
Tug lightly on the tubing to ensure that
the collet is engaged and has a proper
grip on the tubing.
FEED WATER SUPPLY (cont.)
FLOW RESTRICTOR
REPLACEMENT PROCEDURE
Each time the Reverse Osmosis cartridge is
changed, you will need to replace the flow
restrictor in the drain line as well.
Be sure to wash your hands before handling
inner parts of the system.
12
1
2
Installation Instructions
FAUCET ASSEMBLY
FAUCET MOUNTING INSTALLATION
Be sure there is room underneath the sink to
make the needed connections. Select one of
the following locations to install the faucet:
In an existing sink spray attachment or soap
dispenser hole.
In a hole to be drilled in the sink top.
In a hole to be drilled in the countertop,
next to the sink.
NOTE: Be sure the faucet base will fit flat
against the surface at the selected location
so the gasket will seal.
1. If drilling is needed, make a 1-1/4 dia.
hole. Be sure to use the proper procedure
for drilling porcelain or stainless steel.
Special drill bits may be needed. Consult
a qualified plumber for proper procedure.
2. Remove the faucet, thin o-ring (D), faucet
base (E), bottom base gasket (F), lock
washer (G), hex nut (H) and mounting
bracket (I) from the packaging.
3. Feed the 3/8 blue banded, 1/4 black tube
(attached to the Reverse Osmosis System)
and the 3/8 black tube (included in
separate packaging) up through the
mounting hole in the sink or countertop.
This step may require two people to
assemble. See page 14 for Optional
One Person Faucet Tubing Installation.
4. Feed the two black tubes up through the
gasket (F), faucet base (E) and O-ring (D).
NOTE: For ease of service and maintenance,
keep tubing lengths long enough so removal
of the Reverse Osmosis system from under
the sink is possible.
5. Push the 1/4 black and 3/8 black tubing
onto their respective fittings on the body (B).
NOTE: To ease insertion, submerge tubing ends
into hot water for a few minutes to soften.
6. Seat the base (E) and body (B) together.
Make sure the O-ring and gasket are
in place when the base meets the body.
The faucet handle will be at the 3 o’clock
position with respect to the base.
7. Slide the lock washer onto the threaded
stem of the body (B), then thread the hex
nut (H) onto the stem. Screw about halfway up.
NOTE: If installing faucet on a stainless steel
sink, slide on installation spacer (M) before the
lock washer.
8. Screw the blue tipped tubing adapter (K)
onto the threaded stem of the body (B).
9. Push the blue banded tubing into the
adapter. It should go in about 3/4. Pull on
it to make sure it is installed correctly.
10. Feed the tubing and stem back down
through the 1-1/4 hole.
11. Lower the faucet assembly into place
in the mounting hole and orient to final
position. Place the mounting bracket (I)
above the lock washer (G) around the
faucet stem. While holding the mounting
bracket in place, securely tighten the
hex nut. This step may require two people.
Mounting
bracket (I)
Base (E)
Hex nut (H)
Handle
Spout
Gasket (F)
Tubing adapter (K)
Lock washer (G)
O-ring (D)
Cap
ASSEMBLED
3/8barb
fitting
3/8(black)
drain tubing
1/4(black)
drain tubing
1/4barb fitting
Tubing adapter (K)
3/8(blue banded)
outlet tubing
Hex Nut (H)
Lock washer (G)
Installation spacer (M)
(as needed)
Body (B)
From ROFrom ROTo drain
13
Installation Instructions
FAUCET ASSEMBLY (cont.)
BATTERY INSTALLATION
1. Use a small flat blade screwdriver or coin
to remove the battery tray (A) at the side
of the faucet base.
2. Install one CR2032, 3 volt battery (B)
+ side down into the battery tray (A).
3. Slide tray into faucet base (C) until the
battery tray (A) edge is flush with the side
of the base.
4. The blue light (D) will flash 5 times,
indicating a proper installation and system
reset. If you want to reinitiate the start-up
sequence, remove the battery for 45–60
seconds; the electronics need to fully
discharge. Then put the battery back in.
5. The light is normally off. After 6 months
of use, the light will flash again every
30 seconds, indicating the proper time
to replace the filter cartridge.
NOTE: The blue light may stop blinking if
allowed to blink for an extended period of
time. To ensure proper operation, the battery
should be replaced with every filter change.
OPTIONAL ONE PERSON
FAUCET TUBING INSTALLATION
1. From under the sink, gather the 1/4 drain
line (black), 3/8 drain line (black) and 3/8
outlet tube (blue banded) in one hand with
the drain tubes the same length and the
outlet tube offset approximately 6 inches.
2. Wrap a rubber band around all 3 tubes.
3. Insert a typical No. 2 pencil through the
rubber band location.
4. Rotate the pencil down until it is in line
with the tubing and push up through the
mounting hole. Release the grip on the
pencil and the tubes will remain in
position for easier faucet connection.
+
(B) Battery
(C) Faucet base
(A) Battery
tray
(D) Blue light
14
Installation Instructions
FILTRATION DRAIN CONNECTION
PREFERRED INSTALLATION:
OPTION A—BASEMENT ACCESS
INSTALLATION
Route the drain line DIRECTLY from the Reverse
Osmosis system to a standpipe in the basement,
bypassing the air gap provided in the faucet. The
air gap installation is left to the discretion of the
installer. The drain line may also be routed to a
floor drain or washtub, provided that the air gap
is maintained. Special air gap fittings are available
to connect the drain line to the top of the standpipe.
Check and comply with local plumbing codes as you plan.
CAUTION: The options detailed below are the ONLY approved installation
configurations. Do not use any drain saddle device.
NOTE: Failure to follow these Installation Instructions will void the warranty, and the installer will
be responsible for any service, repair or damages caused thereby.
15
Drain line from the Reverse Osmosis system
1
1 minimum air gap
must be maintained
PREFERRED INSTALLATION:
OPTION B—DRY-VENTED P-TRAP
INSTALLATION
Install a separate dry-vented p-trap under the
sink to be used exclusively for the Reserve
Osmosis drain line. A dry-vented p-trap is a
p-trap that has its own vent/stack. Attach the
drain line adapter to the p-trap and secure it
with the slip joint nut and washer as shown.
The drain line MUST be routed through the air
gap provided in the RO water faucet.
Reverse
Osmosis
drain line
Optional disposer
Installation Instructions
FILTRATION DRAIN CONNECTION (cont.)
PREFERRED INSTALLATION:
OPTION C—WET-VENTED P-TRAP
INSTALLATION
Install a p-trap under the sink to be used
exclusively for the Reverse Osmosis drain line.
A wet-vented p-trap is a p-trap that shares a
common vent/stack. Attach the drain line adapter
to the p-trap and secure it with the slip joint nut
and washer as shown. The drain line MUST be
routed through the air gap provided in the RO
water faucet. Locate the Reverse Osmosis p-trap
as high as possible (minimum of 4above
horizontal).
1
SECONDARY INSTALLATION:
OPTION D—DRAIN LINE ADAPTER
INSTALLATION
CAUTION:
Using Option D
may result in clogging under adverse
conditions and requires periodic
inspection/cleaning by the user.
DO NOT INSTALL THE DRAIN LINE
DOWNSTREAM OF A DISPOSER OR IN A
HORIZONTAL PIPE. Install the drain line adapter
under the sink as shown (parts included). The
baffle tee shown must be installed to prevent a
clog in the Reverse Osmosis drain line. Route the
drain line from the air gap to the drain line
adapter, ensuring that there are no dips, loops or
low spots in the line. The drain line adapter
should be aligned vertically so that the hose
connection points upward (the hose connection
should never be allowed to drop below 45° from
this vertical position). This installation MAY result
in a slight drain noise in the sink drain when the
Reverse Osmosis system is regenerating. If this
happens, simply place the sink drain stoppers
in the strainer to suppress it.
Reverse
Osmosis
drain line
Optional disposer
Reverse
Osmosis
drain line
4 minimum
Drain line
adapter
Maximum 45°
Baffle tee
(mandatory)
Optional
disposer
From
second sink
or disposer
45°
From faucet air gap
Drain line
adapter
Drain line connection should
be 180° opposite existing
horizontal pipe/baffle-tee as
shown in diagram
Drain line adapter
Proper drain line adapter orientation.
16
Installation Instructions
STORAGE TANK AND STARTUP
STORAGE TANK INSTALLATION
1. Remove the protective cap from the top
of the tank.
2. Apply 2–3 wraps
of thread tape,
in a clockwise
direction, to the
tank threads.
3. Install the push-to-connect fittings on the
threaded fitting on the tank as shown.
4. Push the 3/8 red banded tubing from the
Reverse Osmosis System into the fitting
on the storage tank.
SYSTEM STARTUP PROCEDURE
CAUTION:
If installing the unit in
new construction, ensure that house plumbing
is flushed thoroughly before opening the water
supply valve.
1. Check that all tubing connections are
secure.
2. Turn on the Feed Water Supply Valve.
3. Check all connection points for leaks.
4. Follow the Sanitization procedures on
page 19.
5. After sanitization is complete, reinstall
prefilter, postfilter and Reverse Osmosis
cartridges.
6. Membrane contains a food grade
preservative. Allow the system to fill the
tank, then drain it completely four times
before using the water from the system.
7. Recheck all water connection points a few
days later to check for small leaks.
Storage
tank
Thread
tape
17
Troubleshooting TipsConsumer Support Troubleshooting Tips
Installation Instructions Safety InstructionsOperating Instructions
Care and cleaning of the reverse osmosis system.
Prefilter, Postfilter and Reverse Osmosis Membrane Cartridge Replacement Procedure
When the blue light in the faucet base flashes,
it is time to replace the prefilter and postfilter.
This will occur every 6 months.
Be sure to wash your hands before handling
inner parts of the system.
1. Turn OFF the icemaker (if attached to
the system).
2. Turn off water supply to the system.
3. Turn ON faucet to drain tank (may take several
minutes). Turn OFF faucet when tank is empty.
4. Remove the prefilter, postfilter and Reverse
Osmosis cartridge by rotating to the left about
1/3 turn.
5. Follow Sanitizing the Reverse Osmosis System
procedure found on page 19.
6. Remove foil on top of new replacement
cartridges. Install new cartridges into the
manifold by turning to the right about 1/3 turn
until the alignment marks line up and the
cartridges stop. DO NOT OVERTIGHTEN. The
cartridges will rise up as they are turned.
NOTE: The prefilter and postfilter are identical.
You may install either filter in the prefilter or
postfilter position. The reverse osmosis cartridge
is installed in the center position.
7. Turn ON water supply to fill the system
(may take up to four hours). Check for leaks.
8. Remove the battery tray and replace the
battery, positive “+” side down, to reset timer
and monitor function in faucet base (see Battery
Installation for proper procedure).
9. If only the prefilter and postfilter are replaced,
turn the faucet ON and empty the filled storage
tank. If the membrane cartridge is replaced, fill
and empty the storage tank a total of four times.
(This will remove the food grade preservatives
contained in new membranes. This preservative
will give product water an unpleasant taste
and odor.)
10. Once the storage tank is full, turn on the
icemaker.
NOTE: System should be sanitized when replacing
the prefilter and postfilter cartridge or the Reverse
Osmosis cartridge. Follow the Sanitizing the Reverse
Osmosis System procedure on page 19.
18
ON
OFF
To remove
Reverse
Osmosis
Prefilter Postfilter
ge.com
Sanitizing the Reverse Osmosis System
Sanitize upon installation of the Reverse Osmosis
system and after servicing inner parts, including
replacement of prefilter, postfilter and the
membrane cartridge.
Be sure to wash your hands before handling
inner parts of the system.
CAUTION: Before sanitizing, be sure to
remove all cartridges. Chlorine will destroy the
Reverse Osmosis membrane cartridge.
1. Follow steps 1 through 4 under Prefilter,
Postfilter and Reverse Osmosis Membrane Cartridge
Replacement Procedure.
2. Fill the empty canister labeled “Sanitization
Canister” with water to within 1 inch of the
upper opening. Add 1 oz. (2 Tbsp.) ordinary
household bleach. Install canister into the
prefilter canister position by turning to the right
about 1/3 turn until the alignment marks line
up and the canister stops.
3. Install the two additional “sanitiziation canisters”
into the membrane canister and postfilter
openings in the manifold by turning to the right
about 1/3 turn until the alignment marks line
up and the canister stops.
4. Turn ON water supply. Turn ON faucet until
water begins to flow from the faucet, then turn
faucet OFF. Allow system to fill for 10 minutes.
5. Turn faucet ON and allow water to flow for 20
minutes, or until bleach odor is gone. Turn OFF
water supply again. Turn ON faucet to drain
the system.
6. Once the system is drained, turn the faucet OFF
and remove the canisters by turning to the left
about 1/3 turn. Keep these in a safe place until
needed the next time.
19
Sanitization
canisters
Prefilter
position
Consumer SupportTroubleshooting Tips
Operating InstructionsSafety Instructions
Installation Instructions
Operating Instructions Safety InstructionsInstallation Instructions
Troubleshooting TipsConsumer Support
Care and cleaning of the reverse osmosis system.
To obtain replacement filters, call toll-free GE Appliance Parts at 800.626.2002 (U.S.),
800.663.6060 (Canada–English), 800.361.3869 (Canada–French), or visit the store where
you purchased your reverse osmosis system.
CAUTION: Before servicing the Reverse Osmosis system, close the water supply/saddle valve
and open the RO water faucet. Allow the system to drain.
Prefilter/Postfilter Cartridge Replacement FQROPF Carbon Block
Reverse Osmosis Cartridge Replacement FQROMF Thin Film Polyamide
The Water Test Kit
To obtain an independent laboratory water test kit, please call Legend Technical Services at
1.800.826.8553 ext. 47 and leave your contact details. They will contact you to find out what water
tests you are interested in, and inform you of the cost of the testing. You will then receive a kit that
will include all necessary tests to properly indicate the performance level of your system. Product
water should be tested a minimum of every six months.
NOTE: When the TDS reduction of the system falls below 75%, it is time to replace the reverse
osmosis cartridge in addition to the prefilter and postfilter.
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84

GE Water Dispenser PXRQ15F Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à