EcoSmart CB QC MEDLRG Manuel utilisateur

Catégorie
Chauffe-eau
Taper
Manuel utilisateur
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL
ECO 8 | ECO 11 | ECO 18 | ECO 24 | ECO 27 | ECO 36
IMPORTANT SAFETY INFORMATION
When installing or using any high voltage electrical appliance, basic safety precautions should always be
followed. Under no circumstance should you attempt to clean, install, inspect, repair, disassemble or
otherwise service this water heater, without first shutting off all power to the unit directly at the circuit
breaker box. SERIOUS BODILY INJURY OR DEATH COULD OCCUR IF YOU IGNORE THIS WARNING.
THIS PRODUCT SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIAN AND A QUALIFIED PLUMBER IN
ACCORDANCE WITH ALL NATIONAL, STATE, PROVINCIAL AND LOCAL ELECTRICAL & PLUMBING CODES.
PLEASE READ THESE INSTRUCTIONS THOROUGHLY AND COMPLETELY PRIOR TO INSTALLATION & USE.
FAILURE TO DO SO COULD CAUSE PROPERTY DAMAGE, SERIOUS INJURY, OR DEATH.
This manual should be given to the homeowner after installation and should be retained for future reference.
Tested and certified by the Water Quality Association against NSF/ANSI 372 for lead free
compliance.
1
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING
DANGER!
WATER TEMPERATURE SAFETY SETTING
Safety and energy conservation are factors to be considered when selecting the
water temperature setting of water heater’s thermostat. Water temperatures
above the 125°F can cause severe burns or death from scalding. Be sure to read
and follow the warnings outlined on the label pictured below. This label is also
located on the water heater near the thermostat access panel.
Notice: Mixing valves are recommended for reducing
point of use water temperature by mixing hot and cold
water in branch water lines. It is recommended that a
mixing valve complying with the Standard for
Temperature Actuated Mixing Valves for Hot Water
Distribution Systems, ASSE 1017 be installed.
The chart shown above may be used as a guide in
determining the proper water temperature for your
home.
DANGER: Households with small children,
disabled, or elderly persons may require a 120°F or lower
thermostat setting to prevent contact with “HOT” water.
The temperature of the water in the heater is regulated
by the electronic control on the front of the water
heater. To comply with safety regulations, the
thermostat was set at 120°F before the water heater was
shipped from the factory.
Please consult Section 10
to learn more about setting
your heaters temperature.
Rotate right for higher
temperature (up to 140F)
or rotate left for cooler
temperature (as low as
80F) will be displayed on
the screen above the knob.
2
ABOUT YOUR TANKLESS WATER HEATER
Congratulations on the purchase of your Electric Tankless Water Heater! You have purchased the most
technologically-advanced electric tankless water heater on the market today.
Your new electric tankless water heater features advanced water flow rate and temperature sensors designed to
modulate power to the heating elements to maintain a precise user-selected output water temperature
between 80°F and 140°F (subject to incoming water temperature and power of the selected model).
To get the best performance and energy savings from your electric tankless water heater, it is important that it
be installed in accordance with our instructions and the electrical and plumbing codes applicable to your area,
and that you read this manual thoroughly for important operating instructions and tips.
If you have questions at any time, please contact us directly at:
EcoSmart Green Energy Products
400 Captain Neville Drive, Waterbury, CT 06705
Toll Free: 1-877-474-6473
Support@EcoSmartUS.com
CONTENTS
1. BEFORE INSTALLATION
2. SELECTING A LOCATION TO INSTALL
3. MOUNTING YOUR WATER HEATER
4. PLUMBING INSTALLATION
5. ELECTRICAL INSTALLATION
6. SIZING GUIDE
7. GENERAL OPERATING INSTRUCTIONS
8. MAINTENANCE
9. TROUBLE SHOOTING GUIDE
10. USER INTERFACE
1- BEFORE INSTALLATION
PLEASE READ THESE INSTRUCTIONS THOROUGHLY AND COMPLETELY PRIOR TO INSTALLATION & USE.
FAILURE TO FOLLOW INSTRUCTIONS COULD CAUSE PROPERTY DAMAGE, SERIOUS PERSONAL INJURY, OR
DEATH.
By installing this product, you acknowledge the terms of the manufacturer’s warranty. Once the heater is
installed, do not return product to the place of purchase. If you have any questions regarding the warranty or
product return policies, please contact EcoSmart at 1-877-474-6473.
Inspect all components. The contents of your box should include one of the following units:
ECO 8
ECO 11
ECO 18
ECO 24
ECO 27
ECO 36
3
2- SELECTING A LOCATION TO INSTALL
This product is designed to be installed indoors only. You may install your unit in an outdoor location so long as
it is mounted in a suitable enclosure that protects it from rain, splashed water, direct sunlight, debris, and
insects.
DO NOT install this product in a location where it may be subjected to freezing temperatures. If the water inside
your tankless water heater freezes, it can cause severe and permanent damage that is not covered under your
warranty.
DO NOT locate the water heater in a location that is difficult to access.
Make sure that the water heater and hot water outlet pipe are out of reach of children so they are unable to
tamper with the temperature controls or injure themselves by touching the hot water outlet pipe. The outlet
water pipe can get very hot.
This product does NOT require venting.
Avoid installing your tankless water heater in a location prone to excessive humidity, moisture, or dust, or in an
area where it may be splashed with water or other liquids. DO NOT install under water pipes or air conditioning
lines that might leak or condense moisture that could then drip onto the heater. DO NOT install above electrical
boxes or junctions.
CAUTION: The water heater should not be located in an area where leakage will result in damage to the area
adjacent to it or to lower floors of the structure. Where such areas cannot be avoided, it is recommended that
a suitable catch pan, adequately drained, be installed under the water heater.
3- MOUNTING YOUR WATER HEATER
Your tankless water heater should be secured to the mounting surface with 4 screws (minimum 1-inch long)
using the built-in mounting brackets on each side of the heater. Make sure that the mounting surface is solid
and secure, and ensure that the unit is level prior to securing the screws. For ease of installation and servicing,
we recommend that this product be installed in an upright position with the inlet and outlet water connections
at the bottom of the unit for the ECO 18, ECO 24, ECO 27, and ECO 36, and with the inlet and outlet water
connections on the left and right sides of the unit for the ECO 8 and ECO 11.
Recommended Clearances: 12 inches above and below the heater
6 inches in front of and to the sides of the heater
CAUTION: Combustible materials should be kept at least 24 inches away from your water heater and the hot
water outlet pipe.
4
4- PLUMBING INSTALLATION
Please follow all plumbing instructions carefully. We recommend that this product be installed by a licensed and
qualified plumber in accordance with all applicable national, state, provincial, and local plumbing codes.
Installation Instructions
STEP 1: Connect the HOT WATER line to the water heater OUTLET located on the left side of the heater when
facing unit. Connect the COLD WATER line to the water heater marked INLET on the right side when facing unit.
STEP 2: After tightening both fittings at the water heater, open several hot water faucets and allow water to run
though the water heater for at least 2 to 3 minutes. This process purges all the air from the water lines and
MUST be performed prior to turning on the power at the unit. FAILURE TO FOLLOW THIS STEP CAN CAUSE
PERMANENT DAMAGE TO THE HEATING ELEMENTS. If any maintenance is performed on the water heater or the
home’s plumbing system that may introduce air into the plumbing pipes, it is important to turn the power off to
the water heater and purge the air out of the lines before allowing the unit to power up.
STEP 3: Carefully inspect all connections, unions, and the pressure relief valve (if installed) for leaks.
IMPORTANT NOTES:
1. Do not solder any pipes with unit connected to pipes heat from soldering may damage the flow
sensor. Doing so will void the warranty.
2. This automatic tankless water heater is equipped with both computer-controlled and electro-
mechanical auto resetting thermostat switches for high-limited temperature protection. Since this
product does not use a storage tank, the use of a temperature pressure relief valve (T&P) is not required
for most installations. UL Standard 499 does NOT require that a pressure relief valve be used. However,
a T&P valve may be required to meet installation codes in your area. If one is required, install the
pressure relief valve in accordance with local codes and ensure that it operates correctly and that air is
purged from the valve prior to installing the water heater. When connecting to Flex or High
Temperature CPVC pipe, we recommend that a T&P valve be used for added safety.
Please note: Installations in the Commonwealth of Massachusetts and State of Kentucky require a
pressure relief valve. Please check your local installation codes for any special requirements.
3. The maximum operating water pressure is 150 PSI. If the water pressure is higher, a pressure reducing
valve must be installed on the main incoming water supply line prior to installing the electric tankless
water heater.
4. Flexible water heater hoses are recommended to be used with your water heater as part of the
installation. When connecting the inlet water pipe to the unit, make sure to use a wrench to hold the
unit’s connection, and another wrench to tighten, so that the flow sensor on the unit will not be
loosened or damaged. Serious internal damage to the water heater can occur if the inlet or outlet
connections are over tightened or if solder connections were made.
5. We recommend that a manual shut-off valve (ball valve) is installed on the inlet and outlet of the water
heater so that there is a convenient shut-off point available in the event that future maintenance or
servicing is required. It is extremely important to flush the lines to eliminate all plumbing paste or
residue in the lines caused by any welding or soldering before connecting pipes to the water heater.
We recommend that all the water pipes or hoses within 3 feet of the inlet and outlet connections be rated for
high temperature applications with a 150°F minimum.
5
5- ELECTRICAL INSTALLATION
EcoSmart recommends that this product be installed by a licensed and qualified electrician in accordance with
all applicable national, state, provincial, and local electrical codes. As with all electrical appliances, under no
circumstances should you attempt to install, repair or disassemble this water heater without first shutting off all
power to the unit directly at the fuse or breaker box. Make sure to shut off all breakers. SERIOUS BODILY
INJURY OR DEATH COULD OCCUR IF YOU IGNORE THIS WARNING.
All wiring (wire gauge) and circuit protection (breakers) must comply with the U.S. National Electrical Code (NEC)
in the USA, or the Canadian Electrical Code (CEC) in Canada. Failure to do so could result in property damage
and/or personal injury, and void your warranty. Note: The Canadian Electrical Code generally requires that all
supply wires and corresponding circuit protection used for domestic hot water heating and hydronic heating
applications be sized to a minimum of 125% of the maximum current rating of the heater (see model
specifications below for details).
Before installing this product, ensure that the home has sufficient electrical power available to handle the
maximum amperage load of the applicable model.
IMPORTANT NOTES:
Model ECO 8 and ECO 11 require 1 set of wire and ground (see wiring diagram)
Model ECO 18 requires 2 sets of wire and ground (see wiring diagram)
Model ECO 24 and ECO 27 require 3 sets of wire and ground (see wiring diagram)
Model ECO 36 requires 4 sets of wire and ground (see wiring diagram)
Please see electrical specifications by model and wiring diagram on the next page for additional electrical
information.
Each set of wires must be connected to its own individual double pole breaker.
Installation Instructions
STEP 1: Take each wire pair and connect them to one breaker (see wiring diagram). Make sure that each breaker
is connected with one black wire and one red wire
STEP 2: Using a suitable wire gauge that meets all applicable electrical codes for the size of the breakers used,
run the correct sets of wire from the home’s main breaker panel to the tankless water heater.
STEP 3: A separate ground conductor for each incoming circuit is required.
STEP 4: DOUBLE CHECK the electrical connections to make sure they are correct and that all wire connections
are tight and secure. Also confirm that the correct breaker size and wire gauge has been used and confirm that
the unit has been connected to a ground in accordance with applicable codes.
STEP 5: Confirm that all the air has been purged from the water lines prior to turning on power to the unit. Refer
to STEP 2 in the plumbing installation section.
CAUTION: Ensure that you have made the correct connections. You must follow the wire connection as shown
to ensure proper operation of the unit. If you mix up one set of wires with another, the unit will not operate
correctly even though it turns on and otherwise appears to function properly.
The water heater is now installed and ready to use! Follow the General Operating Instructions to complete the
setup. We highly recommend that this is done with the homeowner present.
6
Electrical Specifications by Model
ECO 8
ECO11
ECO 18
ECO 24
ECO 27
ECO 36
1
2
2
3
3
4
240 V
240 V
240 V
240 V
240 V
240 V
8 kW
13 kW
18 kW
24 kW
27 kW
36 kW
8 kW
6.5 kW
9 kW
8 kW
9 kW
9 KW
33 AMPS
54 AMPS
75 AMPS
100 AMPS
112.5 AMPS
150 AMPS
1 x 40 AMP
1 X 60 AMP
2 X 40 AMP
3 x 40 AMP
3 X 40 AMP
4 X 40 AMP
1 x 8 AWG
1 x 6 AWG
2 X 8 AWG
3 x 8 AWG
3 X 8 AWG
4 X 8 AWG
Wiring Diagram
Circuit Break #1 Circuit Breaker #2 Circuit Breaker #3 Circuit Breaker #4
208V Jumper Setting
When using 208V service for these units instead of 240V you must change the jumper setting to ensure proper
unit functionality. Using a 208V service will give you 75% capacity. There are two different types of control
boards: Thru Hole and Surface Mount. For assistance determining control board type, please visit
EcoSmartUS.com
Model
ECO 8
ECO 11
ECO 18
ECO 24
ECO 27
ECO 36
New Jumper Setting (Thru Hole)
8
8
5.5
5.5
5.5
7
New Jumper Setting (Surface Mount)
8
7
7
5.5
7
7
L1
BLACK
L1
RED
ECO 8 ECO 11 requires 1
breaker and 1 set of wires
ECO 18 requires 2 sets of breakers and wires
ECO 24 ECO 27 require 3 sets of breakers and wires
ECO 36 requires 4 sets of breakers and wires
L2
BLACK
L2
RED
L4
BLACK
L4
RED
L3
BLACK
L3
RED
7
6- SIZING GUIDE
Please use the chart below to see how many gallons per minute your tankless water heater can produce with
your incoming water temperature. The gallons per minute is calculated assuming 105°F outlet temperature.
Incoming Water
Temperature
ECO 8
ECO 11
ECO 18
ECO 24
ECO 27
ECO 36
40°F
0.8
1.4
1.9
2.5
2.8
3.8
45°F
0.9
1.5
2.0
2.7
3.1
4.1
50°F
1.0
1.6
2.2
3.0
3.4
4.5
55°F
1.1
1.8
2.5
3.3
3.7
4.9
60°F
1.2
2.0
2.7
3.6
4.1
5.5
65°F
1.4
2.2
3.1
4.1
4.6
6.1
70°F
1.6
2.5
3.5
4.7
5.3
7.0
75°F
1.8
3.0
4.1
5.5
6.1
8.2
80°F
2.2
3.6
4.9
6.6
7.4
9.8
(Gallons per Minute)
FLOW REGULATOR OPTIONAL
To ensure the optimal temperature output and overall performance of your tankless water heater you may
require a flow regulator. These flow regulators are installed on the outlet connection of your tankless water
heater and limit the maximum volume coming out of your unit to a specified flow rate to prevent the exit
temperature from becoming too cool. To learn more about flow regulators or find out how to purchase one for
your tankless water heater visit us online at EcoSmartUS.com or contact us at 1-877-474-6473.
Steps for Choosing a Flow Regulator
1. Find your model in the chart on the left
2. Choose the column with the inlet water temperature closest to your geographical location
3. Take the GPM or gallons per minute you find and match it with the corresponding flow regulator on the
right
Inlet Water Temperature
40°F
50°F
60°F
70°F
EcoSmart Part
Number
Maximum Flow Rate
Connection Size
ECO 8
1.0
1.0
1.0
1.5
ECO IFR 1-2
1.0 GPM
1/2" Compression
ECO 11
1.0
1.0
1.5
2.0
1.5 GPM
1/2" Compression
ECO 18
2.0
2.0
2.0
3.0
2.0 GPM
1/2" Compression
ECO 24
2.0
2.0
3.0
4.0
ECO IFR 3-4
2.0 GPM
3/4" NPT
ECO 27
2.0
3.0
4.0
5.0
3.0 GPM
3/4" NPT
ECO 36
3.0
4.0
5.0
5.0
4.0 GPM
3/4" NPT
5.0 GPM
3/4" NPT
*Selection based on inlet temperature above and outlet temperature of 105°F
8
7- GENERAL OPERATING INSTRUCTIONS
Operating your new tankless water heater is similar to using any traditional water heating system. However, it is
very important that you carefully read all of the setup procedures and operating instructions and tips to ensure
the maximum performance and energy savings from your new water heater. We recommend that all members
of the household read these General Operating Instructions.
How your new water heater works: Your tankless water heater does not store hot water like a conventional
tank-type water heater. It contains high powered heating elements that are capable of heating water on-
demand. As soon as you turn on a hot water faucet, a sophisticated flow sensor recognizes that you have turned
on the water. This sensor measures flow rate while another sensor measures the incoming water temperature.
This information is transmitted continually to the computer logic controls which decide how much power to
send to the heating elements to heat the water to your desired temperature. Once the water faucet is turned off
your water heater will turn off as well.
8- MAINTENANCE
To ensure maximum performance of your water heater and to reduce the risk of a water leak, we recommend
the following maintenance:
Inspect the connections on the inlet and outlet of the water heater at least on an annual basis for any signs of
damage or failure. Any signs of damage, cracks, leakage or weakness should be addressed. Take care not to over
tighten the connections. Serious internal damage to your water heater can occur if you over tighten the water
heater connections at the unit.
IMPORTANT NOTES:
As with all electrical appliances, under no circumstances should you attempt to install, repair or disassemble this
water heater without first shutting off all power to the unit directly at the fuse or breaker box. SERIOUS BODILY
INJURY OR DEATH COULD OCCUR IF YOU IGNORE THIS WARNING.
When any maintenance is performed on the water heater or the home’s plumbing system that may introduce air
into the plumbing pipes, it is important to turn the power off to the water heater and purge the air out of the
lines before allowing the unit to power up. FAILURE TO DO SO COULD CAUSE PERMANENT DAMAGE TO THE
HEATING ELEMENT AND VOID YOUR WARRANTY.
If you have a water supply with a high level of mineralization (hard water), you should increase the frequency of
your maintenance.
9- TROUBLE SHOOTING GUIDE
Are you having problems with your water heater?
Please call or email our customer service and technical support team for any help you may need.
TOLL FREE 1-877-474-6473
9
The following table represents some of the most common technical support questions we receive. Before calling
us, please read thoroughly to see if your question or problem is addressed.
PROBLEM
POSSIBLE CAUSE
SOLUTION
Water heater is not heating at all
(water is flowing but the unit is not
heating - the outgoing water
temperature is the same as the
cold water supply) - the digital
display does NOT light up.
No power or incorrect
wiring.
Make sure the breakers at main electrical panel are ON. You
may have a faulty breaker or unit may be wired incorrectly.
Flow rate is too low /
water pressure is too
low.
Your water heater has an activation flow rate of approximately
0.3 GPM. If your water flow rate is less than this level, your unit
will not activate. Increase the flow rate.
Water heater is not heating at all
(water is flowing but the unit is not
heating - the outgoing water
temperature is the same as the
cold water supply) The digital
display DOES light up.
Internal part failure.
Please call us for technical assistance.
Water heater is heating, but the
water temperature is not hot
enough.
User temperature
setting too low.
Turn up the temperature setting on the unit.
Flow rate is too high.
Depending on your incoming water temperature and the power
output of your model, your water flow rate may exceed the
physical heating capacity of your water heater. Reduce the flow
rate by installing an EcoSmart Flow Regulator. Use the chart in
section 6 to find out which flow regulator works best for your
particular model.
Crossed wires.
If it’s a new installation, have your electrician double check the
wiring. Is possible that the wiring is incorrect.
Voltage less than 240
volts.
The heating elements on your water heater are design for 240
volts. When used with a lower voltage, they produce less
heating power. You may need to upgrade to a larger model.
Mixing too much cold
water.
You do not need to mix as much cold water with your tankless
water heater compared to when you use a conventional water
heater. You may also have an anti-scald feature on your faucet
that is mixing cold water. These types of faucets can usually be
adjusted to reduce the amount of cold water mixed.
The water temperature at the
faucet is less than the temperature
setting of my water heater.
Voltage less than 240
volts.
The computer chips in your tankless water heater are
programmed with the expectation that your incoming line
voltage is 240 volts. If you have less than 240 volts, it may affect
the reading on your water heater’s digital display and cause it to
read slightly higher than the actual output temperature. To
compensate for this, increase the setting on your water heater if
you need / want hotter water.
Anti-Scald
pressure/balancing
valve or tempering
valve.
Your faucet may have an anti-scald feature or a tempering valve
that automatically mixes cold water even when you turn your
control lever or handle to full hot. These devices are usually
adjustable so you can turn off the cold mix completely. You can
compensate for this by increasing the setting on your water
heater if you need/want hotter water.
Thermal loss due to
long pipe run
As the hot water from the heater runs through the hot water
delivery system to your faucet, some heat will be lost especially
if it has long distance to travel or the pipes are cold. This is
normal. You can compensate for this by increasing the setting on
your water heater if you need/want hotter water.
10
10- USER INTERFACE
Power
Click adjustment knob, the display will turn on
Click the adjustment knob again, the display will turn off
C/F Conversion
Press the adjustment knob for 3 seconds, the display will change from Fahrenheit to Celsius or vice
versa
Temperature Control
Turning the knob clockwise increases the set output water temperature
Turning the knob counter clockwise decreases the set output water temperature
You can set or adjust the temperature at any time between 80°F 140°F (27°C 60°C). The temperature
can be changed to your desired setting. The display will only stay on when the unit is in use or when you
are setting the temperature.
CAUTION: Removing the cover to change the temperature set point exposes electrical shock and burn hazards,
which can cause INJURY or DEATH. Adjustment should only be done by a licensed plumber or electrician.
DANGER: Hotter water increases the potential for Hot Water SCALDS.
ECO 8 ECO 11
ECO 18 ECO 24 ECO 27 ECO 36
1. Hot Water Outlet
5. Adjustment Knob & Temperature Control
9. Electrical Strain Relief
2. Cold Water Inlet
6. Wire Connection
10. Mounting Bracket (1”)
3. Celsius/Fahrenheit Conversion (Press & Hold 3 sec.)
7. Brass Compression Nut
4. Temperature Set Point Display
8. Brass Compression Ferrule
Model Number
Height
Width
Depth
Pipe Centers Distance
ECO 8
11
𝟏
𝟐
inches
8 inches
3
𝟑
𝟒
inches
-
ECO 11
11
𝟏
𝟐
inches
8 inches
3
𝟑
𝟒
inches
-
ECO 18
17 inches
14 inches
3
𝟑
𝟒
inches
5
𝟕
𝟖
inches
ECO 24
17 inches
17 inches
3
𝟑
𝟒
inches
5
𝟕
𝟖
inches
ECO 27
17 inches
17 inches
3
𝟑
𝟒
inches
5
𝟕
𝟖
inches
ECO 36
17 inches
21 inches
3
𝟑
𝟒
inches
9
𝟏𝟑
𝟏𝟔
inches
11
ECOSMART GREEN ENERGY PRODUCTS
MANUFACTURERS WARRANTY
MAINLAND USA and CANADA- LIMITED LIFETIME
OUTSIDE MAINLAND USA 5 YEARS
1. PRODUCT WARRANTY: EcoSmart Green Energy Products warrants to the original purchaser at the original address
or the authorized transferee of such purchaser (collectively, the “Buyer”) EcoSmart Tankless Water Heater and its
components to be free from defects in materials and workmanship, under normal use and service from the date of
installation, provided that the Product is installed within thirty (30) days from date of receipt and installed by a
licensed electrician and plumber (specific proof required) and maintained in accordance with Products written
instructions. The Product Warranty will be in effect upon receipt of the Warranty Registration by EcoSmart U.S.
offices. The Warranty Registration is included in the Operating and Maintenance Manual supplied with each new
product and must be fully completed and submitted via fax, mail or website within (30) days of receipt of Product.
Incomplete Warranty Registrations will not be accepted. Product Warranties are void without receipt of Warranty
Registration within (30) days of receipt of Product.
SUCH WARRANTIES DO NOT COVER:
Product failure caused by liming, sediment buildup, chemical corrosion, chlorine/chloride corrosion, or
freezing.
Product failure caused by the failure to remove air from system prior to or during operation.
Product misuse, tampering or misapplication, accidental damage, improper installation or the application of
improper voltage.
Costs incurred for shipping, delivery, handling and/or administrative charges.
Labor charges of any kind.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTY, EXPRESSED OR IMPLIED,
INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE OR PATENT OR OTHER INTELLECTUAL PROPERTY RIGHT INFRINGEMENT.
2. LIMITATION OF REMEDIES AND DAMAGES: EcoSmart Green Energy Products liability and Buyer’s exclusive remedy
hereunder will be limited solely to repair or replacement of Product under Warranty by EcoSmart Service Center with
respect to any claim made within the applicable Warranty. EcoSmart Green Energy Products reserves the right to
accept or reject any such claim in whole or in part. EcoSmart Green Energy Products will not accept the return of any
product without prior written approval from EcoSmart Service Center and the issuance of a Return Merchandise
Authorization Number clearly marked on the outside packaging of the return shipment. ECOSMART GREEN ENERGY
PRODUCTS WILL NOT BE LIABLE, UNDER ANY CIRCUMSTANCES, FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES,
INCLUDING BUT NOT LIMITED TO LABOR COSTS OR LOST PROFITS RESULTING FROM THE USE OF (OR INABILITY TO
USE) THE PRODUCTS OR FROM THE PRODUCTS BEING INCORPORATED IN OR BECOMING A COMPONENT OF ANY
OTHER PRODUCT OR GOODS.
3. WARRANTY REGISTRATION: To be covered under the EcoSmart Green Energy Products Manufacturer’s Limited
Lifetime Warranty Buyer must register product within thirty (30) calendar days of receipt of Product using the
Warranty Registration Card included with the Product, this Warranty may be submitted via mail to ECOSMART GREEN
ENERGY PRODUCTS LOCATED AT 400 Captain Neville Drive, Waterbury, CT, 06705. THIS IS A LIMITED LIFETIME
MANUFACTURER’S WARRANTY THAT CONVEYS BENEFITS TO THE ORIGINAL PURCHASERS, SUBJECT TO THE TERMS
AND CONDITIONS SET FORTH HEREIN. Keep Product documents in a safe and secure location. Buyer obligation under
the terms of purchase and sale require that Warranty Registration must be returned within the prescribed timeframe
(within 30 calendar days) and retain all proof of purchase, installer receipts for Warranty in order to protect Buyer’s
rights and obtain Manufacturer’s Limited Lifetime Warranty benefits. The Warranty resides with the Buyer with proof
of purchase; not simply with an individual in possession of a Product. If the Product is to be installed in new
construction at a date later than 30 days from the date of receipt, send further information in advance of thirty (30)
day deadline when known so we may update your Warranty record.
4. FURTHER LIMITATIONS AND EXCLUSIONS AFFECTING YOUR WARRANTY: This warranty is void if the Product is not
installed in accordance with relevant, local electrical and plumbing codes and in accordance with the installation
12
instructions specified by the manufacturer. Local codes will override manufacturer’s instructions at the time of
installation and if additional installation parts are required, the costs will be the responsibility of Buyer. Above ground
level installations must be protected with drip pans and drains just as the codes call for protective requirements used
in regular hot water tank installations. Buyer hereby accepts the entire responsibility for ascertaining whether they
have sufficient electrical power at their residence to operate our Electric Tankless Water Heaters as indicated in our
specifications which are readily available at our website (WWW.ECOSMARTUS.COM), in our brochures and contained
in the shipping box for installers to read before installations. If, within (30) days of purchase and prior to installation,
the Buyer finds that the purchased unit is not suitable for their demands Buyer must return the unit to the EcoSmart
office. Buyer is responsible for any charges that may be incurred to complete the return. A Buyer is eligible for a full
refund or credit ONLY if the returned unit is received by EcoSmart within thirty (30) calendar days of receipt AND has
been inspected by EcoSmart and found to be in the same condition as when purchased. Only when these two
conditions are met will a Buyer receive a refund or replacement unit. EcoSmart Green Energy Products will not accept
the return of any product without prior written approval from EcoSmart Green Energy Products and the issuance of a
Return Merchandise Authorization Number clearly marked on the outside packaging of the return shipment.
AFTER (30) CALENDAR DAYS FROM RECEIPT OF PRODUCT THERE WILL BE NO RETURNS OR WARRANTY WITHOUT
RECEIPT OF WARRANTY REGISTRATION BY ECOSMART US. BUYER ACCEPTS ALL SALES AS FINAL. ANY ALTERATION TO
THE PRODUCT VOIDS ALL WARRANTIES. ECOSMART GREEN ENERGY PRODUCTS IS NOT RESPONSIBLE FOR ANY OTHER
CHARGE OR EXPENSE INCURRED, OTHER THAN THE ORIGINAL PURCHASE PRICE OF THE PRODUCT. ECOSMART GREEN
ENERGY PRODUCTS shall not be liable for consequential, special, incidental or contingent expenses or damages arising
directly or indirectly from any defect in or of the Product; nor will EcoSmart Green Energy Products be liable for any
water damage arising directly or indirectly from the use of the Product or from the failure of or defect in any
component part or connecting plumbing. EcoSmart Green Energy Products and Buyer agree to the above terms in
their entirety and accept all sales as final without recourse to a credit card company or other financial institution and
hereby agree to stipulations and specifications defined within Manufacturer’s Limited Lifetime Warranty.
5. Warranty Procedure for service: Have a licensed electrician determine the exact issue that requires repair. Please
note that technical support is available for qualified technicians only (licensed electricians and/or plumbers). Technical
support that involves potentially dangerous electrical conditions is not available to unqualified persons. When
contacting EcoSmart Service Center, please be sure that the technician has a copy of the original Warranty
Registration and has reviewed the “Homeowners and Installation Manual” that was supplied with the Product.
EcoSmart Technical Assistance, at its sole discretion, will determine the best method for repair. Methods of repair
include, but are not limited to, replacement of specific part of Product or replacement of whole unit. If a whole unit
requires replacement under the terms of this Manufacturer’s Warranty, the original unit must be returned to the
ECOSMART office. Buyer must secure the cost of return delivery and replacement unit with a valid U.S. credit card.
Credit Card Authorization Forms are available upon request. If the replaced unit arrives at the EcoSmart office within
ten (10) calendar days of shipment of new unit and is found to comply within the specifications of this Manufacturer’s
Warranty then the credit card will not be charged, otherwise, Buyer will be charged amount of replacement unit and
shipment cost as agreed upon within Credit Card Authorization Form. If EcoSmart Technical Assistance determines a
component requires repair or replacement under the terms of this Manufacturer’s Limited Lifetime Warranty, the part
will be shipped via standard ground delivery. If faster shipping service is desired, the Buyer must select and pay for
same.
ANY QUESTIONS REGARDING OUR FIVE (5) YEAR WARRANTY SHOULD BE DIRECTED TO OUR SERVICE CENTER BY
CALLING TOLL FREE 877-474-6473 BETWEEN 8:00 AM and 5:00 PM MONDAY thru FRIDAY EASTERN TIME. NO RETURN
WILL BE ACCEPTED BY ECOSMART WITHOUT PRIOR APPROVAL AND THE ISSUANCE OF RETURN MERCHANDISE
AUTHORIZATION NUMBER CLEARLY MARKED ON THE EXTERIOR OF PACKAGING.
EcoSmart Green Energy Products • 400 Captain Neville Drive, Waterbury, CT, 06705 • TOLL FREE: 877-474-6473
13
ECOSMART SPANISH MANUAL
INSTRUCCIONES DE INSTALACIÓN Y MANUAL DEL PROPIETARIO
ECO 8 | ECO 11 | ECO 18 | ECO 24 | ECO 27 | ECO 36
INFORMACIÓN IMPORTANTE SOBRE SEGURIDAD
Cuando se instala o usa un aparato eléctrico de alto voltaje, siempre se deben tener en cuenta precauciones de
seguridad básicas. En ningún caso se debe intentar limpiar, instalar, inspeccionar, reparar, desarmar ni reparar de
ninguna otra manera este calefón calentador de agua sin apagar primero toda la alimentación de energía a la unidad
directamente en la caja de disyuntores. SI SE IGNORA ESTA ADVERTENCIA SE PUEDEN PRODUCIR LESIONES
CORPORALES GRAVES O LA MUERTE.
ESTE PRODUCTO DEBE SER INSTALADO POR UN ELECTRICISTA CALIFICADO Y UN PLOMERO CALIFICADO DE
ACUERDO CON TODOS LOS CÓDIGOS ELÉCTRICOS Y DE PLOMERÍA NACIONALES, ESTATALES, PROVINCIALES Y
LOCALES.
POR FAVOR, LEA ESTAS INSTRUCCIONES METICULOSAMENTE Y EN SU TOTALIDAD ANTES DE LA INSTALACIÓN Y EL
USO. DE NO HACERLO SE PODRÍAN PRODUCIR DAÑOS MATERIALES, LESIONES GRAVES O LA MUERTE.
Este manual se debe entregar al propietario después de la instalación y se debe conservar para referencia futura.
Probado y certificado por la Water Quality Association de conformidad con la norma NSF/ANSI
372 sobre cumplimiento de ausencia de plomo.
14
INFORMACIÓN IMPORTANTE SOBRE SEGURIDAD
LEA TODAS LAS INSTRUCCIONES ANTES DEL USO
¡PELIGRO!
GRADUACIÓN SEGURA DE LA TEMPERATURA DEL AGUA
La seguridad y la conservación de la energía son factores a considerar cuando se
selecciona la graduación de temperatura del agua del termostato del calefón
calentador de agua. La temperatura del agua por encima de 125°F puede causar
quemaduras graves o la muerte por escaldaduras. Asegúrese de leer y observar las
advertencias indicadas en la etiqueta que se ve en la imagen de abajo. Esta etiqueta
también se encuentra en el calefón calentador de agua cerca del panel de acceso al
termostato.
Aviso: Se recomiendan las válvulas mezcladoras para
reducir la temperatura del agua en el punto de uso
mezclando agua caliente y fría en las tuberías de derivación.
Se recomienda instalar una válvula mezcladora que cumpla
con la Norma para Válvulas Mezcladoras Activadas por
Temperatura para Sistemas de Distribución de Agua Caliente
ASSE 1017.
El cuadro que aparece arriba se puede usar como guía para
determinar la temperatura del agua adecuada para su hogar.
PELIGRO: Los hogares donde hay niños pequeños,
discapacitados o ancianos pueden necesitar una graduación
del termostato de 120° F o menos para evitar el contacto con
agua "CALIENTE". La temperatura del agua del calefón se
regula mediante el control electrónico que está en el frente
del mismo. Para cumplir con las regulaciones de seguridad, el
termostato se graduó en 120°F antes del embarque del
calefón en fábrica.
Por favor, consulte la Sección
10 para más información
acerca de la graduación de
temperatura de su calefón.
Rote hacia la derecha para
mayor temperatura (hasta
140°F) o hacia la izquierda
para menos temperatura
(hasta 80°F); aparecerá en la
pantalla encima de la perilla.
15
ACERCA DE SU CALEFÓN SIN TANQUE
¡Felicitaciones por la compra del calefón eléctrico sin tanque! Usted ha comprado el calefón eléctrico sin tanque
tecnológicamente más avanzado del mercado actual.
Su nuevo calefón eléctrico sin tanque presenta sensores avanzados de temperatura y velocidad de caudal diseñados
para modular energía a los elementos calefactores para mantener la temperatura exacta del agua de salida
seleccionada por el usuario entre 80°F y 140°F (sujeto a la temperatura del agua de entrada y el suministro de energía
del modelo seleccionado).
Para obtener el mejor rendimiento y ahorro energético de su calefón eléctrico sin tanque es importante que se lo
instale de acuerdo con nuestras instrucciones y los códigos eléctricos y de plomería aplicables a su área y que lea este
manual meticulosamente para compenetrarse de las instrucciones operativas y sugerencias importantes.
Si tiene alguna pregunta en cualquier momento, por favor, comuníquese con nosotros directamente en:
EcoSmart Green Energy Products
400 Captain Neville Drive, Waterbury, CT 06705
Teléfono para llamadas gratuitas: 1-877-474-6473
Support@EcoSmartUS.com
CONTENIDO
1. ANTES DE LA INSTALACIÓN
2. SELECCIÓN DEL LUGAR DE INSTALACIÓN
3. MONTAJE DE SU CALEFÓN
4. INSTALACIÓN DE PLOMERÍA
5. INSTALACIÓN ELÉCTRICA
6. GUÍA DE TAMAÑOS
7. INSTRUCCIONES OPERATIVAS GENERALES
8. MANTENIMIENTO
9. GUÍA PARA LA SOLUCIÓN DE PROBLEMAS
10. INTERFAZ DEL USUARIO
1 ANTES DE LA INSTALACIÓN
POR FAVOR, LEA ESTAS INSTRUCCIONES METICULOSAMENTE Y EN SU TOTALIDAD ANTES DE LA INSTALACIÓN Y EL
USO. SI NO SE RESPETAN LAS INSTRUCCIONES SE PODRÍAN PRODUCIR DAÑOS MATERIALES, LESIONES PERSONALES
GRAVES O LA MUERTE.
Al instalar este producto usted reconoce los términos de la garantía del fabricante. Después de instalado el calefón no
devuelva el producto al lugar de compra. Si tiene alguna pregunta sobre la garantía o las políticas de devolución del
producto, por favor, comuníquese con EcoSmart al 1-877-474-6473.
Inspeccione todos los componentes. El contenido de la caja debe incluir una de las siguientes unidades:
ECO 8
ECO 11
ECO 18
ECO 24
ECO 27
ECO 36
16
2 - SELECCIÓN DEL LUGAR DE INSTALACIÓN
Este producto únicamente se puede instalar en interiores. Puede instalar su unidad en una ubicación exterior en tanto
y en cuanto se lo coloque en un cerramiento adecuado que lo proteja de la lluvia, salpicaduras de agua, la luz solar
directa, residuos e insectos.
NO instale este producto en un lugar donde pueda estar sujeto a temperaturas de congelación. Si el agua que está
dentro de su calefón sin tanque se congela puede causar daños graves y permanentes que no son cubiertos por la
garantía.
NO coloque el calefón en un lugar de difícil acceso.
Asegúrese de que el calefón y el caño de salida del agua caliente no estén al alcance de los niños, de manera que no
estén en condiciones de alterar los controles de temperatura ni de lesionarse al tocar la cañería de salida del agua
caliente. La cañería del agua de salida puede estar muy caliente.
Este producto NO necesita ventilación.
Evite instalar su calefón sin tanque en un lugar propenso a la humedad excesiva o el polvo o en un área donde pueda
ser salpicado con agua u otros líquidos. NO lo instale debajo de cañerías de agua o aire acondicionado que puedan
tener pérdidas o condensar humedad que pudieran luego gotear dentro del calefón. NO lo instale encima de tableros
o cajas de empalme eléctricos.
PRECAUCIÓN: El calefón no se debe ubicar en un área donde un derrame provoque daños al área adyacente o los
pisos inferiores de la estructura. Si no se pueden evitar esas áreas, se recomienda instalar una bandeja de goteo
adecuada, con buen drenaje, debajo del calefón.
3 - MONTAJE DE SU CALEFÓN
Su calefón sin tanque se debe sujetar a la superficie de montaje con 4 tornillos (1 pulgada de largo como mínimo)
usando las ménsulas de montaje incorporadas a cada lado del calefactor. Asegúrese de que la superficie de montaje
sea sólida y firme y que la unidad quede nivelada antes de sujetar los tornillos. Para facilitar la instalación y el
mantenimiento, recomendamos que este producto se instale en posición vertical, con las conexiones de agua de
entrada y salida en la parte inferior de la unidad en el caso de las ECO 18, ECO 24, ECO 27 y ECO 36 y con las
conexiones de agua de entrada y salida en los lados izquierdo y derecho en el caso de las unidades ECO 8 y ECO 11.
Separaciones recomendadas: 12 pulgadas encima y debajo del calefón
6 pulgadas delante y a los costados del calefón
PRECAUCIÓN: Los materiales combustibles se deben mantener a 24 pulgadas de distancia de su calefón y del caño
de salida de agua caliente.
17
4 INSTALACIÓN DE PLOMERÍA
Por favor, siga todas las instrucciones de plomería con atención. Recomendamos que este producto sea instalado por
un plomero matriculado y calificado de conformidad con todos los códigos de plomería nacionales, estatales,
provinciales y locales aplicables.
Instrucciones de instalación
PASO 1: Conecte la cañería de AGUA CALIENTE con la SALIDA del calefón ubicada del lado izquierdo mirando la unidad
de frente. Conecte la cañería de AGUA FRÍA con la ENTRADA marcada del calefón ubicada del lado derecho mirando la
unidad de frente.
PASO 2: Después de apretar las dos uniones del calefón, abra varios grifos de agua caliente y deje correr el agua a
través del calefón durante al menos 2 ó 3 minutos. Este proceso purga todo el aire de las cañerías y SE DEBE realizar
antes de encender la alimentación eléctrica de la unidad. SI NO SE REALIZA ESTE PASO SE PUEDEN PRODUCIR DAÑOS
PERMANENTES EN LOS ELEMENTOS CALEFACTORES. Si se realiza alguna tarea de mantenimiento del calefón o del
sistema de cañerías del hogar que pudiera introducir aire en las cañerías es importante apagar el suministro eléctrico
del calefón y purgar el aire de las cañerías antes de encender la unidad.
PASO 3: Inspeccione con atención todas las conexiones, uniones y la válvula de alivio de presión (en caso de haber)
para detectar cualquier pérdida.
AVISOS IMPORTANTES:
1. No suelde ningún caño con la unidad conectada a la cañería; el calor de soldadura puede dañar el sensor de
caudal. Si lo hace se anulará la garantía.
2. Este calefón automático sin tanque está equipado con interruptores de termostato de restauración
automática electromecánicos y controlados por computadora para protección contra alta temperatura por
limitación. Como este producto no usa un tanque de almacenamiento en la mayoría de las instalaciones no
se necesita una válvula de alivio de presión y temperatura (T&P). La norma UL 499 NO exige el uso de una
válvula de alivio de presión. Sin embargo, tal vez sea necesario instalar una válvula T&P para cumplir con los
códigos de su área. Si es así, instale la válvula de alivio de presión de acuerdo con los códigos locales y
asegúrese de que funcione correctamente y que el aire se purgue de la válvula antes de instalar el calefón. Al
conectar con un tubo CPVC flexible o de alta temperatura recomendamos usar una válvula T&P para mayor
seguridad.
Por favor, tenga en cuenta lo siguiente: Las instalaciones realizadas en el Estado de Massachusetts y en el
Estado de Kentucky exigen válvula de alivio de presión. Por favor, consulte los códigos de instalación
locales para ver los requisitos especiales.
3. La presión de agua operativa máxima es 150 psi. Si la presión de agua es superior, se debe instalar una
válvula reductora de presión en la tubería de suministro de agua de entrada principal antes de instalar el
calefón eléctrico sin tanque.
4. Se recomienda el uso de mangueras flexibles para calefón como parte de la instalación. Al conectar el caño
de agua de entrada a la unidad asegúrese de usar una llave para sujetar la conexión de la unidad y otra llave
para ajustar, de manera que el sensor de caudal de la unidad no se suelte ni dañe. Se pueden producir daños
internos graves en el calefón si las conexiones de entrada o salida se aprietan en exceso o si se realizan
conexiones de soldadura.
5. Recomendamos instalar una válvula de cierre manual (válvula esférica) en la entrada y salida del calefón de
manera que haya un punto de cierre conveniente disponible en caso de ser necesario realizar alguna tarea de
mantenimiento o reparación en el futuro. Es sumamente importante lavar las cañerías con chorro de agua
para eliminar cualquier pasta o residuo de plomería de las mismas que pudiera ser causado por soldadura
antes de conectar los caños al calefón.
Recomendamos que todas las cañerías o mangueras de agua que se encuentren dentro de 3 pies de distancia de las
conexiones de entrada y salida tengan capacidad nominal para aplicaciones de alta temperatura con un valor mínimo
de 150°F.
18
5 INSTALACIÓN ELÉCTRICA
EcoSmart recomienda que este producto sea instalado por un electricista matriculado y calificado de conformidad con
todos los códigos de electricidad nacionales, estatales, provinciales y locales aplicables. Como sucede con todos los
aparatos eléctricos, en ningún caso debe intentar instalar, reparar ni desarmar este calefón sin antes desconectar
todo el suministro eléctrico de la unidad directamente en la caja de fusibles o disyuntor. Asegúrese de desconectar
todos los disyuntores. SI SE IGNORA ESTA ADVERTENCIA SE PUEDEN PRODUCIR LESIONES CORPORALES GRAVES O
LA MUERTE.
Todo el cableado (calibre del cable) y la protección de circuitos (disyuntores) deben cumplir con el Código Eléctrico
Nacional en EE.UU. (NEC) o el Código Eléctrico Canadiense de Canadá (CEC). De lo contrario se pueden producir daños
materiales y/o lesiones personales y se anula la garantía. Nota: El Código Eléctrico Canadiense generalmente exige
que todos los cables de suministro y la protección de circuitos correspondiente utilizados para la calefacción
doméstica por agua caliente y las aplicaciones de calefacción hidrónica sean de una medida como mínimo igual al
125% de la capacidad nominal máxima del calefón (vea los detalles en las especificaciones del modelo más abajo).
Antes de instalar este producto, asegúrese de que el hogar tenga suficiente energía eléctrica disponible para manejar
la carga de amperaje máxima del modelo aplicable.
AVISOS IMPORTANTES:
Los modelos ECO 8 y ECO 11 exigen 1 juego de cable y tierra (vea el diagrama de cableado)
El modelo ECO 18 exige 2 juegos de cable y tierra (vea el diagrama de cableado)
Los modelos ECO 24 y ECO 27 exigen 3 juegos de cable y tierra (vea el diagrama de cableado)
El modelo ECO 36 exige 4 juegos de cable y tierra (vea el diagrama de cableado)
Por favor, vea las especificaciones eléctricas por modelo y diagrama de cableado en la página siguiente para
consultar información eléctrica adicional.
Cada juego de cables se debe conectar con su propio disyuntor de doble polo individual.
Instrucciones de instalación
PASO 1: Tome cada par de cables y conéctelo con un disyuntor (vea el diagrama de cableado). Asegúrese de que cada
disyuntor se conecte con un cable negro y un cable rojo
PASO 2: Con un calibre de cable adecuado que cumpla con todos los códigos eléctricos aplicables para el tamaño de
disyuntores utilizados, tienda los juegos correctos de cable desde el tablero del disyuntor principal de su hogar hasta
el calefón sin tanque.
PASO 3: Se necesita un conductor de tierra separado para cada circuito de entrada.
PASO 4: VUELVA A COMPROBAR las conexiones eléctricas para asegurarse de que sean correctas y que todas las
conexiones de cables estén firmes y sujetas. También confirme que se haya utilizado el tamaño de disyuntor y el
calibre de cable correctos y que la unidad se haya conectado a tierra de acuerdo con los códigos aplicables.
PASO 5: Confirme que se haya purgado todo el aire de las cañerías de agua antes de encender el suministro eléctrico
de la unidad. Consulte el PASO 2 de la sección instalación de plomería.
PRECAUCIÓN: Asegúrese de haber hecho las conexiones correctas. Debe seguir la conexión de cables tal como se
muestra para asegurar el funcionamiento adecuado de la unidad. Si mezcla un juego de cables con otro la unidad no
funcionará correctamente aun cuando se encienda y parezca funcionar correctamente. ¡El calefón ya está instalado y
listo para el uso! Siga las Instrucciones Operativas Generales para completar la instalación. Recomendamos
enfáticamente que esto se realice en presencia del propietario.
19
Especificaciones eléctricas por modelo
MODELOS
ECO 8
ECO11
ECO 18
ECO 24
ECO 27
ECO 36
ELEMENTOS
1
2
2
3
3
4
VOLTAJE
240 V
240 V
240 V
240 V
240 V
240 V
MÁX kW
8 kW
13 kW
18 kW
24 kW
27 kW
36 kW
kW POR ELEMENTO
8 kW
6,5 kW
9 kW
8 kW
9 kW
9 KW
AMPERAJE MÁXIMO
33 AMP
54 AMP
75 AMP
100 AMP
112,5 AMP
150 AMP
DISYUNTORES
REQUERIDOS
1 x 40
AMP
1 x 60
AMP
2 x 40
AMP
3 x 40
AMP
3 x 40
AMP
4 x 40
AMP
CALIBRE DE CABLE
REQUERIDO
1 x 8 AWG
1 x 6 AWG
2 x 8 AWG
3 x 8 AWG
3 x 8 AWG
4 x 8 AWG
Diagrama de cableado
Disyuntor #1 Disyuntor #2 Disyuntor #3 Disyuntor #4
Configuración De Puente 208V
Cuando utilice un servicio de 208V para estas unidades de 240V debe cambiar la configuración del puente para
asegurarse de que la unidad funcione correctamente. Si utiliza un servicio de 208V tendrá un 75% de capacidad.
Hay dos tipos diferentes de tableros de control: Agujero pasante y montaje en superficie. Para obtener asistencia
respecto del tipo de tablero de control, visite EcoSmartUS.com
Model
ECO 8
ECO 11
ECO 18
ECO 24
ECO 27
ECO 36
Nueva configuración de puente (Agujero pasante)
8
8
5.5
5.5
5.5
7
Nueva configuración de puente (Montaje en superficie)
8
7
7
5.5
7
7
ECO 8 ECO 11 exigen 1
disyuntor y 1 juego de cables
ECO 18 exige 2 juegos de disyuntores y cables
ECO 24 ECO 27 exigen 3 juegos de disyuntores y cables
ECO 36 exige 4 juegos de disyuntores y cables
L1
NEGRO
L1
ROJO
L2
NEGRO
L2
ROJO
L3
NEGRO
L3
ROJO
L4
NEGRO
L4
ROJO
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

EcoSmart CB QC MEDLRG Manuel utilisateur

Catégorie
Chauffe-eau
Taper
Manuel utilisateur