YOKOGAWA AQ6373B-02 Getting Started Manual

Taper
Getting Started Manual

Ce manuel convient également à

Users
Manual
AQ6373B
Optical Spectrum Analyzer
Getting Started Guide
IM AQ6373B-02EN
5th Edition
Product Registration
Thank you for purchasing YOKOGAWA products.
YOKOGAWA provides registered users with a variety of information and
services.
Please allow us to serve you best by completing the product registration
form accessible from our homepage.
http://tmi.yokogawa.com/
PIM 103-03E
i
IM AQ6373B-02EN
Foreword
Thank you for purchasing the AQ6373B Optical Spectrum Analyzer. This instrument
enables high speed measurement of the optical properties of LD and LED light sources,
and other devices. To improve ease of use, it includes mouse-based user operation and
a brand-new zoom function.
This getting started guide describes the instrument’s functions, operating procedures,
and handling precautions, and provides other important information for use of the
instrument. For correct operation, please read this manual thoroughly before use. After
reading this manual, keep it in a convenient location for quick reference in the event a
question arises during operation. There are three manuals for the AQ6373B including this
one. Read them along with this manual.
Manual Title Manual No. Description
AQ6373B Optical Spectrum
Analyzer
User’s Manual
IM AQ6373B-01EN The manual is located on the CD included in
your package (pdf format). Explains all functions
and operating procedures of the AQ6373B
except remote control and program functions.
AQ6370C/AQ6370D/
AQ6373/AQ6373B/AQ6375
Optical Spectrum Analyzer
Remote Control User’s
Manual
IM AQ6370C-17EN The manual is located on the CD included in
your package (pdf format). Explains functions for
controlling the instrument with communication
commands and program functions.
AQ6373B Optical Spectrum
Analyzer Getting Started
Guide
IM AQ6373B-02EN This guide. Provided as a printed manual.
This guide explains the handling precautions,
basic operations, and specifications of the
AQ6373B.
Model AQ6373B-01,
AQ6373B-02
AQ6373B Optical Spectrum
Analyzer Limited model
User’s Manual
IM AQ6373B-51EN Explains the specifications of the limited model
of the AQ6373B.
The “-EN” in the manual number is the language code.
Contact information of Yokogawa offices worldwide is provided on the following sheet.
Document Description Description
PIM 113-01Z2 List of worldwide contacts
Notes
The contents of this manual are subject to change without prior notice as a result
of improvements in the instrument’s performance and functions. Display contents
illustrated in this manual may differ slightly from what actually appears on your screen.
Every effort has been made in the preparation of this manual to ensure the accuracy
of its contents. However, should you have any questions or find any errors, please
contact your nearest YOKOGAWA dealer.
Copying or reproducing all or any part of the contents of this manual without the
permission of Yokogawa Test & Measurement Corporation is strictly prohibited.
Trademarks
Microsoft and Windows are trademarks or registered trademarks of Microsoft
Corporation in the United States and/or other countries.
Adobe, Acrobat, and PostScript are trademarks or registered trademarks of Adobe
Systems incorporated.
The company and product names used in this manual are not accompanied by the
trademark or registered trademark symbols (TM, ®)
Other company and product names are trademarks or registered trademarks of their
respective companies.
5th Edition : April 2019 (YMI)
All Rights Reserved, Copyright © 2015 Yokogawa Test & Measurement Corporation
ii
IM AQ6373B-02EN
Revisions
1st Edition: March 2015
2nd Edition: April 2017
3rd Edition: October 2017
4th Edition: October 2018
5th Edition: April 2019
iii
IM AQ6373B-02EN
Checking the Contents of the Package
After opening the package, check the following items before beginning use. If any of the
contents are incorrect, missing, or appear to be abnormal, please contact your Yokogawa
dealer or representative.
AQ6373B Main Unit
Check that the model and suffix code on the name plate on the rear of the instrument
match those of your order. When contacting the dealer from which you purchased the
instrument, please give them the instrument number.
MODEL Suffix Code
1
Description
AQ6373B Optical Spectrum Analyzer AQ6373B
Specification -02 Limited Model
-01 Limited Model
-12 Standard Model
-10 Standard Model
Built-in light -L1 Optical alignment source
source
Power cord
2
-D
UL/CSA standard and PSE compliant,
Rated voltage: 125 V
-F VDE/Korean standard, Rated voltage: 250 V
-R Australian standard, Rated voltage: 250 V
-Q British standard, Rated voltage: 250 V
-H Chinese standard, Rated voltage: 250 V
-N Brazilian standard, Rated voltage: 250 V
-T Taiwanese standard, Rated voltage: 125 V
-B Indian standard, Rated voltage: 250 V
-U IEC Plug Type B, Rated voltage: 250 V
-Y No power cord included.
3
1 For products whose suffix code contains “Z,” an exclusive manual may be included. Please
read it along with the standard manual.
2 Make sure that the attached power cord meets the designated standards of the country and
area that you are using it in.
3 Prepare a power cord that complies with the standard specified by the country or region that
the instrument will be used in.
No. (Instrument Number)
Please contact your nearest Yokogawa representative.
AQ6373B-02, -12 AQ6373B-01, -10
iv
IM AQ6373B-02EN
Checking the Contents of the Package
Standard Accessories
Part Name Model or Part No. Quantity Specifications and Notes
Power cord
*
A1006WD 1 UL/CSA standard and PSE compliant
A1009WD VDE/Korean standard
A1024WD Australian standard
A1054WD British standard
A1064WD Chinese standard
A1088WD Brazilian standard
A1100WD Taiwanese standard
A1101WD Indian standard
A1102WD IEC Plug Type B
Rubber feet A9088ZM 2 1 A9088ZM sheet
Manuals
Printed Manuals IM AQ6373B-02EN 1 Getting Started Guide
IM AQ6373B-51EN 1 Accompanying the limited model only
IM AQ6373B-92Z1 1 Document for China
PIM 113-01Z2 1 List of worldwide contacts
Manual CD B8092YB 1 Contains PDFs of the user’s manuals
(For the types of manuals that CD
contains, see Manual CD below.)
Standard accessories are not covered by warranty of this instrument.
* Make sure that the attached power cord meets the designated standards of the country and
area that you are using it in. If the suffix code is -Y, a power cord is not included.
Manual CD
The English directory in the manual CD contains the PDF files shown below. The CD
also contains Japanese manuals.
File Name Manual Title Manual No.
Features & Operation Manual.pdf AQ6373B Optical Spectrum Analyzer IM AQ6373B-01EN
User’s Manual
Communication Interface.pdf AQ6370C/AQ6370D/AQ6373/ IM AQ6370C-17EN
AQ6373B/AQ6375 Optical Spectrum
Analyzer Remote Control
User’s Manual
To view the PDF data, you need Adobe Acrobat Reader or a software application that
can open PDF data.
WARNING
Never play this manual CD, which contains the user’s manuals, in an audio CD
player. Doing so may cause loss of hearing or speaker damage due to the large
sounds that may be produced.
French
AVERTISSEMENT
Ce CD contient les manuels d’utilisation. Ne jamais insérer ce CD dans un lecteur
de CD audio. Cela pourrait entraîner une perte d’audition ou l’endommagement
des enceintes en raison du volume potentiellement élevé des sons produits.
v
IM AQ6373B-02EN
Safety Precautions
This product is designed to be used by a person with specialized knowledge.
This instrument is an IEC safety class I (provided with terminal for protective earth
grounding). The general safety precautions described herein must be observed during all
phases of operation. If the instrument is used in a manner not specified in this manual,
the protection provided by the instrument may be impaired.
This manual is an essential part of the product; keep it in a safe place for future
reference. Yokogawa Electric Corporation assumes no liability for the customer’s failure
to comply with these requirements.
The following symbols are used on this instrument.
Refer to the user's manual.
This symbol appears on dangerous locations on the instrument which require
special instructions for proper handling or use. The same symbol appears in the
corresponding place in the manual to identify those instructions.
Alternating current
ON(power)
OFF(power)
French
À manipuler délicatement.
Toujours se reporter aux manuels d'utilisation et d'entretien. Ce symbole a été
apposé aux endroits dangereux de l'instrument pour lesquels des consignes
spéciales d'utilisation ou de manipulation ont été émises. Le même symbole
apparaît à l'endroit correspondant du manuel pour identifier les consignes qui s'y
rapportent.
Courant alternatif
Marche (alimentation)
Arrêt (alimentation)
vi
IM AQ6373B-02EN
Failure to comply with the precautions below could lead to injury or death or
damage to the instrument.
WARNING
Use the Instrument Only for Its Intended Purpose
The optical measuring instrument is designed to measure the optical
characteristics of light sources and evaluate their performance. Do not use this
instrument for anything other than as an optical measuring instrument.
Check the Physical Appearance
Do not use the instrument if there is a problem with its physical appearance.
Use the Correct Power Supply
Make sure that the power supply voltage matches the instrument’s rated supply
voltage and that it does not exceed the maximum voltage range of the power
cord to use.
Use the Correct Power Cord and Plug
To prevent the possibility of electric shock or fire, be sure to use the power cord
for the instrument. The main power plug must be plugged into an outlet with a
protective earth terminal. Do not invalidate this protection by using an extension
cord without protective earth grounding.
Further, do not use this power cord with other instruments.
Connect the Protective Grounding Terminal
Make sure to connect the protective earth to prevent electric shock before
turning ON the power. The power cord that you can use for the instrument is a
three-prong cord. Connect the power cord to a properly grounded three-prong
outlet.
Do not Impair the Protective Grounding
Never cut off the internal or external protective earth wire or disconnect the
wiring of the protective earth terminal. Doing so poses a potential shock hazerd.
Do not Operate with Defective Protective Grounding or Fuse
Do not operate the instrument if the protective earth or fuse might be defective.
Make sure to check them before operation.
Reference light source output light (when the built-in light source
specification is -L1)
The instrument has a built-in reference light source for alignment adjustment,
and infrared light is always being output from the optical output connector. Never
look into the optical output connector. Infrared light entering the eyes can cause
severe injury and loss of vision.
Do not Operate in an Explosive Atmosphere
Do not operate the instrument in the presence of flammable liquids or vapors.
Operation in such environments constitutes a safety hazard.
Do Not Remove the Covers or Disassemble or Alter the Instrument
Only qualified YOKOGAWA personnel may remove the covers and disassemble
or alter the instrument.
Opening the cover is dangerous, because some areas inside the instrument
have high voltages.
Install or Use the Instrument in Appropriate Locations
This instrument is designed to be used indoors. Do not install or use it outdoors.
Install the instrument so that you can immediately remove the power cord if
an abnormal or dangerous condition occurs.
Safety Precautions
vii
IM AQ6373B-02EN
CAUTION
Operating Environment Limitations
This product is a Class A (for industrial environment) product. Operation of this
product in a residential area may cause radio interference in which case the user is
required to correct the interference.
French
AVERTISSEMENT
Utiliser l’instrument aux seules fins prévues
Cet instrument de mesure optique est prévu pour mesurer les caractéristiques
optiques des sources lumineuses et évaluer leur performance. Ne pas utiliser
cet instrument à d’autres fins que celles de mesure optique.
Inspecter l’apparence physique
Ne pas utiliser l’instrument si son intégrité physique semble être compromise.
Vérifier l’alimentation
Assurez-vous que la tension d’alimentation correspond à la tension d’alimentation
nominale de l’appareil et qu’elle ne dépasse pas la plage de tension maximale
du cordon d’alimentation à utiliser.
Utiliser le cordon d’alimentation et la fiche adaptés
Pour éviter tout risque de choc électrique, utiliser exclusivement le cordon
d’alimentation prévu pour cet instrument. La fiche doit être branchée sur une
prise secteur raccordée à la terre. En cas d’utilisation d’une rallonge, celleci
doit être impérativement reliée à la terre. Par ailleurs, ne pas utiliser ce cordon
d’alimentation avec d’autres instruments.
Brancher la prise de terre
Avant de mettre sous tension, veiller à brancher la mise à la terre de protection
afin d’éviter les chocs électriques. Le cordon d’alimentation que vous utilisez
pour l’instrument est un cordon à trois broches.
Brancher le cordon d’alimentation sur une prise de courant à trois plots et mise
à la terre.
Ne pas entraver la mise à la terre de protection
Ne jamais neutraliser le fil de terre interne ou externe, ni débrancher la borne
de mise à la terre. Cela pourrait entraîner un choc électrique ou endommager
l’instrument.
Ne pas utiliser avec un conducteur de terre ou un fusible défectueux
Ne pas utiliser l’instrument si le conducteur de terre ou le fusible est défectueux.
Vérifier le conducteur de terre et le fusible avant d’utiliser l’instrument.
Source de lumière de référence (lorsque la source de lumière intégrée
correspond aux caractéristiques L1)
Cet instrument dispose d’une source de lumière de référence intégrée pour
les ajustements d’alignement. La lumière infrarouge est toujours émise depuis
le connecteur de sortie optique. Ne regardez jamais directement dans le
connecteur de sortie optique. La lumière infrarouge risquerait de gravement
vous blesser ou de provoquer une perte de vision.
Safety Precautions
viii
IM AQ6373B-02EN
Ne pas utiliser dans un environnement explosif
Ne pas utiliser l’instrument en présence de gaz ou de vapeurs inflammables.
Cela pourrait être extrêmement dangereux.
Ne pas retirer le capot, ni démonter ou modifier l’instrument
Seul le personnel YOKOGAWA qualifié est habilité à retirer le capot et à
démonter ou modifier l’instrument. Certains composants à l’intérieur de
l’instrument sont à haute tension et par conséquent, représentent un danger.
Installer et utiliser l’instrument aux emplacements appropriés
Ne pas installer, ni utiliser l’instrument à l’extérieur ou dans des lieux exposés
à la pluie ou à l’eau.
Installer l’instrument de manière à pourvoir immédiatement le débrancher du
secteur en cas de fonctionnement anormal ou dangereux.
ATTENTION
Limitations relatives à l’environnement opérationnel
Ce produit est un produit de classe A (pour environnements industriels). L’utilisation
de ce produit dans un zone résidentielle peut entraîner une interférence radio que
l’utilisateur sera tenu de rectifier.
Safety Precautions
ix
IM AQ6373-02EN
Alert mark
Safety Precautions
5 Installing the Instrument
7 Turning the Power ON/OFF
Safety Precautions for Laser Products (when the built-in light source
specification is -L1)
This instrument uses a laser light source. This instrument is a Class 1 laser product
as defined by EN 60825-1:2014/IEC 60825-1:2007 Safety of Laser Products-Part 1:
Equipment Classification, Requirements and User’s Guide. In addition, this instrument
complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser
Notice No. 50, dated June 24, 2007.
Laser Class 1 Label
AQ6373B-02,
-12
AQ6373B-01, -10
Laser Class 1 Label
Information about the Laser Light Source Used
Class Laser Type Wavelength Maximum
Output Power
Diameter of
Mode Field
Repetation
Rate
Numerical
Aperture
1 LED 850nm 0.1mW 50µm CW 0.275
Safety Precautions
x
IM AQ6373B-02EN
Regulations and Sales in Each Country or Region
Waste Electrical and Electronic Equipment
Waste Electrical and Electronic Equipment (WEEE), Directive
(This directive is valid only in the EU.)
This product complies with the WEEE directive marking requirement. This marking
indicates that you must not discard this electrical/electronic product in domestic
household waste.
Product Category
With reference to the equipment types in the WEEE directive , this product is
classified as a “Monitoring and Control instrumentation” product.
When disposing of products in the EU, contact your local Yokogawa Europe B. V.
office. Do not dispose in domestic household waste.
EU Battery Directive
EU Battery Directive
(This directive is valid only in the EU.)
Batteries are included in this product. This marking indicates they shall be sorted
out and collected as ordained in the EU battery directive.
Battery type
Lithium battery
You cannot replace batteries by yourself. When you need to replace batteries,
contact your local Yokogawa Europe B.V.office.
Authorized Representative in the EEA
Yokogawa Europe B. V. is the authorized representative of Yokogawa Test &
Measurement Corporation in the EEA for this product. To contact Yokogawa Europe B. V.,
see the separate list of worldwide contacts, PIM 113-01Z2.
關於在台灣銷售
This section is valid only in Taiwan.
關於在台灣所販賣的符合其相關規定的電源線 A1100WD 的限用物質含量信息,請至下麵的
網址進行查詢
https://tmi.yokogawa.com/support/service-warranty-quality/product-compliance/
xi
IM AQ6373B-02EN
Conventions Used in This Manual
Safety Markings
The following markings are used in this manual.
Improper handling or use can lead to injury to the user or damage to
the instrument. This symbol appears on the instrument to indicate
that the user must refer to the user's manual for special instructions.
The same symbol appears in the corresponding place in the user's
manual to identify those instructions. In the manual, the symbol is
used in conjunction with the word “WARNING” or “CAUTION.”
WARNING
Calls attention to actions or conditions that could cause serious or
fatal injury to the user, and precautions that can be taken to prevent
such occurrences.
CAUTION
Calls attentions to actions or conditions that could cause light injury to
the user or damage to the instrument or user’s data, and precautions
that can be taken to prevent such occurrences.
French
AVERTISSEMENT
Attire l’attention sur des gestes ou des conditions susceptibles
de provoquer des blessures graves (voire mortelles), et sur les
précautions de sécurité pouvant prévenir de tels accidents.
ATTENTION
Attire l’attention sur des gestes ou des conditions susceptibles de
provoquer des blessures légères ou d’endommager l’instrument ou les
données de l’utilisateur, et sur les précautions de sécurité susceptibles
de prévenir de tels accidents.
Note
Calls attention to information that is important for proper operation of
the instrument.
xii
IM AQ6373B-02EN
Notations Used on Pages Describing Operating Procedures
On pages that describe the operating procedures, the following notations are used to
distinguish the procedures from their explanations.
Procedure
This subsection contains the operating procedure used to carry out
the function described in the current chapter. All procedures are
written with inexperienced users in mind; experienced users may not
need to carry out all the steps.
Explanation
This subsection describes the setup parameters and the limitations
on the procedures.
Notations Used in the Procedures
Panel Keys and Soft keys
Bold characters used in the procedural explanations indicate characters that are marked on the
panel keys or the characters of the soft keys displayed on the screen menu.
Unit
k: Denotes “1000.” Example: 100kS/s
K: Denotes “1024.” Example: 459KB (file data size)
Conventions Used in This Manual
xiii
IM AQ6373B-02EN
Flow of Operation
The figure below is provided to familarize the first-time user with the general flow of this
instrument operation. For a description of each item, see the relevant section or chapter
of IM AQ6373B-01EN.
Preparing for Measurement
Setting Conditions and Measuring
Waveform Display
Installing the Instrument
Turning the Power ON/OFF
Auto Sweep Setting and
Measurement Other Settings
Waveform Display
Displaying Calculated Waveforms
Marker Display
Searching
Waveform Analysis
Waveform Analysis
GO/NO-GO Judgment
Analysis Data Logging
Saving Display Data and Printing Out
Storage Media
Saving Data
Chapter 5 in IM AQ6373B-02EN
Chapter 7 in IM AQ6373B-02EN
Section 2.1
Section 4.1
Section 4.2 to 4.11
Section 5.1 to 5.4
Section 5.5
Section 5.9
Section 5.13 and 5.14
Section 6.1 to 6.9
Section 6.11
Section 6.14
Section 7.1
Section 7.2 to 7.9
Measurement Start (Sweep)
External Trigger Measurement
Smoothing
Section 4.13
Section 4.16
Section 4.18
Alignment Adjustment
(Wavelength Calibration)
xiv
IM AQ6373B-02EN
Contents
Checking the Contents of the Package .......................................................................................... iii
Safety Precautions ...........................................................................................................................v
Regulations and Sales in Each Country or Region ..........................................................................x
Conventions Used in This Manual ..................................................................................................xi
Flow of Operation ......................................................................................................................... xiii
1 Front Panel ..............................................................................................................................1
2 Rear Panel ...............................................................................................................................2
3 Panel Keys and Knobs ............................................................................................................3
4 LCD Screen .............................................................................................................................6
5 Installing the Instrument ...........................................................................................................8
6 Connecting a Communication Interface .................................................................................12
7 Turning the Power ON/OFF ...................................................................................................14
8 Connecting the DUT ..............................................................................................................20
9 Specications .........................................................................................................................24
10 External Dimensions ..............................................................................................................27
1
IM AQ6373B-02EN
1 Front Panel
Front Panel
AQ6373B
OPTICAL SPECTRUM ANALYZER
USB
POWER
FUNCTION
DATA ENTRY
CENTER
SWEEP
SPAN
LEVEL
ZOOM
SETUP
MARKER
DISPLAY
PEAK
SEARCH
TRACE
ANALYSIS
USER
MEMORY
FILE
SYSTEM
ADVANCE
PROGRAM
OREMOTE
UNDO/
LOCAL
HELP
COARSE
7
8
9
4
5
6
1
2
3
0
.
-
BACK
SPASE
nm/
ENTER
m/
ENTER
OPTICAL INPUT
(
600 1700nm
)
CALIBRATION
OUTPUT
1 2
3
4
5
6
7
8
9
10
COPY
PRESET
11
12
No. Name Function
1 LCD display Displays measured waveform, measurement conditions,
measurement values, etc.
2 Soft key section Used to execute the functions assigned to the soft keys on
the right side of the LCD display
3 FUNCTION section Used to enter settings pertaining to all measurements
(sweep, measurement conditions, data analysis, and
various functions)
4 DATA ENTRY section Used for measurement condition parameter input, label
input, etc.
5 POWER Used to start and shut down the instrument.
6 USB interface Used to connect USB storage media
7 UNDO/LOCAL See the following table(1.3 Panel keys and Knobs)
8 HELP Used to check the contents of the soft key menu displayed
on the screen.
9 OPTICAL INPUT Optical input connector
10 CALIBRATION OUTPUT Reference light source optical output connector used for
alignment adjustments and wavelength calibration (when
the built-in light source specification is -L1)
11 COPY Save the screen as an image file.
12 PRESET Clears all internal settings of the AQ6373B except for the
remote interface (ETHERNET, GP-IB, and RS232) settings.
2
IM AQ6373B-02EN
2 Rear Panel
Rear Panel
1
2
3
4
5
6
7
8 9
10
11
1
2
3 4
5
6
7
8 9
10
11
AQ6373B-02, -12 AQ6373B-01, -10
No. Name Function
1 GP-IB GP-IB port for controlling this unit through an external
computer
2 TRIGGER IN Input connector for synchronous signals for the
synchronous measurement function with the Tunable Laser
Source
3 TRIGGER OUT Output connector for synchronous signals for the
synchronous measurement function with the Tunable Laser
Source
4 ANALOG OUT Analog output
5 MAIN POWER Used to turn the main power ON/OFF
6 Power cord connector Connect the power cord to this connector
7 VIDEO OUT (SVGA) Analog RGB video signal (SVGA-compliant) interface
8 SERIAL RS-232 interface
9 ETHERNET Ethernet Interface
10 USB interface Used to connect USB storage media or USB mouse
11 Exhaust holes
3
IM AQ6373B-02EN
3 Panel Keys and Knobs
FUNCTION Section
The FUNCTION section contains 17 function keys and 4 auxiliary keys. When you press
a function key, information about the function is displayed on the soft key menu located
on the right side of the LCD display.
SWEEP
The SWEEP key contains functions related to sweeping. When you press the SWEEP
key, the soft key menu for sweeping appears.
CENTER
The CENTER key contains functions related to setting the center wavelength and center
frequency for measurements. The soft key functions change depending on whether the
screen display mode is wavelength display mode or frequency display mode.
SPAN
The SPAN key contains functions pertaining to settings for the wavelength span or
frequency span being measured. The soft key functions change according to whether the
screen display mode is wavelength display mode or frequency display mode.
LEVEL
The LEVEL key contains functions related to level axis settings.When you press the
LEVEL key, the soft key menu for setting reference level appears.
SETUP
The SETUP key contains functions related to measurement condition settings.
ZOOM
The ZOOM key contains the zoom function, which allows the user to freely enlarge or
reduce a measured waveform in order to check a small area of the measured waveform,
or to check the overall waveform.
This key is used to set the waveform enlarged/reduced display conditions.
DISPLAY
The DISPLAY key contains functions related to screen display.This key is used to set the
screen to upper/lower 2-split display mode (split mode).
TRACE
The TRACE key contains functions related to trace mode settings.
MARKER
The MARKER key contains functions related to markers.
PEAK SEARCH
The PEAK SEARCH key contains functions for searching for peaks and bottoms in
measured waveforms.
ANALYSIS
The ANALYSIS key contains functions related to measured waveform analysis.
FUNCTION
CENTER
SWEEP
SPAN
LEVEL
ZOOM
SETUP
MARKER
DISPLAY
PEAK
SEARCH
TRACE
ANALYSIS
USER
MEMORY
FILE
SYSTEM
ADVANCE
PROGRAM
OREMOTE
UNDO/
LOCAL
HELP
COPY
PRESET
4
IM AQ6373B-02EN
MEMORY
The MEMORY key contains functions for writing the contents of the active trace to the
unit’s internal memory. When you press the MEMORY key, the traces and memory list
screen (soft key menu) are displayed. A memory number may be entered in the DATA
ENTRY section, or selected using the rotary knob or arrow keys.
FILE
The FILE key contains functions for saving and loading waveform data, program data,
and the like to and from USB storage media (USB memory/HDD).
PROGRAM
The PROGRAM key contains the soft keys related to program functions for controlling
measurements through a program.
SYSTEM
The SYSTEM key contains system-related functions such as monochromator adjusting
optical alignment, wavelength adjustment, hardware setup, and setting initialization.
ADVANCE
The ADVANCE key contains functions for setting reference data used to make
comparison judgments on measured data and for logging analysis data.
USER
Frequently used soft keys can be registered on the soft key menu in the USER key.
Registering frequently used soft keys in the USER key allows you to execute frequently
used functions in a small number of steps.
COPY
The COPY key is used to output the measurement screen to a file.
When you press the COPY key, the measured waveforms and lists displayed on the
screen are output to the internal printer or a file.
PRESET
The PRESET key clears all internal settings of the AQ6373B except for the remote
interface (ETHERNET, GP-IB, and RS232) settings.
UNDO/LOCAL
The key's function changes depending on the status of the instrument when the UNDO/
LOCAL key is pressed. The following table shows the key's functions.
Status of Instrument Function
UNDO action is allowed If the UNDO key is pressed after changing parameter
settings, changing or deleting data, etc., the previous
action (change, deletion, etc.) is canceled and the state
preceding that action is restored.
During user key registration If the UNDO key is pressed during user key registration,
registration mode is canceled and the soft key menu
which appeared when the SYSTEM key was pressed is
displayed again.
During remote control by
external PC (Remote light is on)
Changes the state from the remote state back to the
local state. The remote light turns off.
HELP
When you press the HELP key, a soft key menu of the currently displayed screen is
displayed explanations.
Soft keys for selecting the “MORE INFO” which indicate additional information are
displayed by some soft keys in HELP screen.
3 Panel Keys and Knobs
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43

YOKOGAWA AQ6373B-02 Getting Started Manual

Taper
Getting Started Manual
Ce manuel convient également à

dans d''autres langues