Mitsubishi Electric GT25 Wide Model Le manuel du propriétaire

Taper
Le manuel du propriétaire
GT25 Wide Model
General Description
Thank you for choosing Mitsubishi Electric Graphic Operation
Terminal (GOT).
© 2017 MITSUBISHI ELECTRIC CORPORATION
GT2512-WXTBD
GT2507-WTBD
GT2512-WXTSD
GT2507-WTSD
GT2510-WXTBD GT2510-WXTSD
Prior to use, please read both this manual and the
detailed manual thoroughly to fully understand the
product.
MODEL GT25-W-U-GD-E
Model
code
1D7MS5
IB(NA)-0800564ENG-F(2101)MEE
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
SAFETY PRECAUTIONS
(Always read these precautions before using this equipment.)
Before using this product, please read this manual and the relevant
manuals introduced in this manual carefully and pay full attention to
safety to handle the product correctly.
The precautions given in this manual are concerned with this
product.
In this manual, the safety precautions are ranked as "WARNING"
and "CAUTION".
Note that the CAUTION level may lead to a serious accident
according to the circumstances.
Always follow the instructions of both levels because they are
important to personal safety.
Please save this manual to make it accessible when required and
always forward it to the end user.
[DESIGN PRECAUTIONS]
Indicates that incorrect handling may cause
hazardous conditions, resulting in death or
severe injury.
Indicates that incorrect handling may cause
hazardous conditions, resulting in medium or
slight personal injury or physical damage.
Some failures of the GOT or cables may keep the outputs on or off.
Some failures of a touch panel may cause malfunction of the input objects
such as a touch switch.
An external monitoring circuit should be provided to check for output signals
which may lead to a serious accident.
Not doing so can cause an accident due to false output or malfunction.
Do not use the GOT as the warning device that may cause a serious accident.
An independent and redundant hardware or mechanical interlock is required
to configure the device that displays and outputs serious warning.
Failure to observe this instruction may result in an accident due to incorrect
output or malfunction.
The GOT backlight failure disables the operation on the touch switch(s).
When the GOT backlight has a failure, the POWER LED blinks (orange/blue),
the display section dims, and inputs by a touch switch are disabled.
The display section of the GOT is an analog-resistive type touch panel.
Do not touch two points or more simultaneously on the display section.
Doing so may cause a touch switch near the touched points to operate
unexpectedly, or may cause an accident due to an incorrect output or
malfunction.
When programs or parameters of the controller (such as a PLC) that is
monitored by the GOT are changed, be sure to reset the GOT, or turn on the
unit again after shutting off the power as soon as possible.
Not doing so can cause an accident due to false output or malfunction.
If a communication fault (including cable disconnection) occurs during
monitoring on the GOT, communication between the GOT and PLC CPU is
suspended and the GOT becomes inoperative.
A system where the GOT is used should be configured to perform any
significant operation to the system by using the switches of a device other
than the GOT on the assumption that a GOT communication fault will occur.
Not doing so can cause an accident due to false output or malfunction.
To maintain the security (confidentiality, integrity, and availability) of the GOT
and the system against unauthorized access, DoS
*1
attacks, computer
viruses, and other cyberattacks from unreliable networks and devices via
network, take appropriate measures such as firewalls, virtual private networks
(VPNs), and antivirus solutions.
Mitsubishi Electric shall have no responsibility or liability for any problems
involving GOT trouble and system trouble by unauthorized access, DoS
attacks, computer viruses, and other cyberattacks.
*1 DoS: A denial-of-service (DoS) attack disrupts services by overloading
systems or exploiting vulnerabilities, resulting in a denial-of-service (DoS)
state.
WARNING
CAUTION
WARNING
[MOUNTING PRECAUTIONS]
Products with the Cl.I, DIV.2 mark on the rating plate are suitable for use in
Class I, Division 2, Groups A, B, C and D hazardous locations, or
nonhazardous locations only.
This mark indicates that the product is certified for use in the Class I,
Division2 environment where flammable gases, vapors, or liquids are not
likely to exist under normal conditions.
When using the products in the Class I, Division 2 environment, observe the
following to reduce the risk of explosion.
• This device is open-type and is to be installed in an enclosure suitable for
the environment and require a tool or key to open.
• Warning - Explosion Hazard - Substitution of any component may impair
suitability for Class I, Division 2.
• Warning - Explosion Hazard - Do not connect or disconnect equipment or
disconnect external connection terminals unless power has been removed
or the area is known to be non-hazardous.
•The wireless LAN communication unit interface of this equipment cannot be
used in Class I, Division 2 environments.
Les produits marqués Cl.I, DIV.2 sur la plaque signalétique peuvent être
utilisés en Class I, Division 2, local dangereux de groupe A, B, C et D, ou
uniquement en local non dangereux.
Ce logo indique que le produit est homologué pour utilisation en
environnement de Class I, Division 2 où, dans des circonstances anormales,
il peut y avoir présence de gaz, vapeurs ou liquides inflammables.
Si le produit est utilisé en environnement de Class I, Division 2, observer les
précautions suivantes pour réduire le risque d'explosion.
• Cet appareil est de type ouvert et il doit être installé dans une enceinte
appropriée à l'environnement et ne pouvant être ouverte qu'au moyen d'une
clé ou d'un outil.
• Avertissement - Danger d'explosion - Toute substitution de composant peut
compromettre l'aptitude à l'utilisation en Class I, Division 2.
• Avertissement - Danger d'explosion - Ne pas connecter ou déconnecter
l'équipement ni déconnecter les bornes de connexion externes quand le
circuit est sous tension, ni avant de d'être assuré de l'absence
d'atmosphère inflammable.
• L’interface latérale et l’interface d’extension de cet équipement ne peuvent
être utilisées dans les environnements de Classe I, Division 2.
Do not bundle the control and communication cables with main-circuit, power
or other wiring.
Run the above cables separately from such wiring and keep them a minimum
of 100 mm apart.
Not doing so noise can cause a malfunction.
Do not press the GOT display section with a pointed material as a pen or
driver.
Doing so can result in a damage or failure of the display section.
When the GOT connects to an Ethernet network, the IP address setting is
restricted according to the system configuration.
When a GOT2000 series model and a GOT1000 series model are on an
Ethernet network, do not set the IP address 192.168.0.18 for the GOTs and
the controllers on this network.
Doing so can cause IP address duplication at the GOT startup, adversely
affecting the communication of the device with the IP address 192.168.0.18.
The operation at the IP address duplication depends on the devices and the
system.
When using the Ethernet interface, set a different network for port 1 and
port 2.
Turn on the controllers and the network devices to be ready for
communication before they communicate with the GOT.
Failure to do so can cause a communication error on the GOT.
When the GOT is subject to shock or vibration, or some colors appear on the
screen of the GOT, the screen of the GOT might flicker.
Be sure to shut off all phases of the external power supply used by the
system before mounting or removing the GOT main unit to/from the panel.
Not doing so can cause the unit to fail or malfunction.
Be sure to shut off all phases of the external power supply used by the
system before mounting or removing the unit or the option unit onto/from the
GOT.
Use the GOT in the environment that satisfies the general specifications
described in this manual.
Not doing so can cause an electric shock, fire, malfunction or product
damage or deterioration.
When mounting the GOT to the control panel, tighten the mounting screws in
the specified torque range (0.36 N•m to 0.48 N•m) with a Phillips-head
screwdriver No. 2.
Undertightening can cause the GOT to drop, short circuit or malfunction.
Overtightening can cause a drop, short circuit or malfunction due to the
damage of the screws or unit.
When mounting the wireless LAN communication unit on the GOT, fit it to the
wireless LAN communication unit interface and tighten the mounting screws
in the specified torque range (0.10 N•m to 0.14 N•m) with a Phillips-head
screwdriver No.1.
Under tightening can cause the GOT to drop, short circuit or malfunction.
Overtightening can cause a drop, failure or malfunction due to the damage of
the screws or unit.
When closing the USB environmental protection cover, fix the cover to the
GOT by pushing the USB mark on the latch firmly to comply with the
protective structure.
Remove the protective film of the GOT.
When the user continues using the GOT with the protective film, the film may
not be removed.
Do not operate or store the GOT in the environment exposed to direct
sunlight, high temperature, dust, humidity, or vibrations.
WARNING
CAUTION
WARNING
CAUTION
[WIRING PRECAUTIONS]
[TEST OPERATION PRECAUTIONS]
[STARTUP/MAINTENANCE PRECAUTIONS]
Be sure to shut off all phases of the external power supply used by the
system before wiring.
Failure to do so may result in an electric shock, product damage or
malfunctions.
Make sure to ground the FG terminal of the GOT power supply section solely
for the GOT (ground resistance: 100 Ω or less, ground cable diameter: 1.6
mm or more).
Not doing so may cause an electric shock or malfunction.
When tightening the terminal screws, use a Phillips-head screwdriver No.2.
Terminal screws which are not to be used must be tightened always at torque
0.5 N•m to 0.8 N•m.
Otherwise there will be a danger of short circuit against the solderless
terminals.
Use applicable solderless terminals and tighten them with the specified
torque. If any solderless spade terminal is used, it may be disconnected
when the terminal screw comes loose, resulting in failure.
Correctly wire the GOT power supply section after confirming the rated
voltage and terminal arrangement of the product.
Not doing so can cause a fire or failure.
Tighten the terminal screws of the GOT power supply section in the specified
torque range (0.5 N•m to 0.8 N•m).
Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of
the screws or unit.
Exercise care to avoid foreign matter such as chips and wire offcuts entering
the GOT.
Not doing so can cause a fire, failure or malfunction.
The module has an ingress prevention label on its top to prevent foreign
matter, such as wire offcuts, from entering the module during wiring.
Do not peel this label during wiring.
Before starting system operation, be sure to peel this label because of heat
dissipation.
Plug the communication cable into the GOT interface and tighten the
mounting screws and the terminal screws in the specified torque range.
Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of
the screws or unit.
Before testing the operation of a user-created monitor screen (such as
turning on or off a bit device, changing the current value of a word device,
changing the set value or current value of a timer or counter, and changing
the current value of a buffer memory), thoroughly read the manual to fully
understand the operating procedures.
During the test operation, never change the data of the devices which are
used to perform significant operation for the system.
False output or malfunction can cause an accident.
When power is on, do not touch the terminals.
Doing so can cause an electric shock.
Correctly connect the battery connector.
Do not charge, disassemble, heat, short-circuit, solder, or throw the battery
into the fire.
Doing so will cause the battery to produce heat, explode, or ignite, resulting in
injury and fire.
Before starting cleaning or terminal screw retightening, always switch off the
power externally in all phases.
Not switching the power off in all phases can cause a unit failure or
malfunction.
Undertightening can cause a drop, short circuit or malfunction.
Overtightening can cause a drop, short circuit or malfunction due to the
damage of the screws or unit.
Do not disassemble or modify the unit.
Doing so can cause a failure, malfunction, injury or fire.
Do not touch the conductive and electronic parts of the unit directly.
Doing so can cause a unit malfunction or failure.
The cables connected to the unit must be run in ducts or clamped.
Not doing so can cause the unit or cable to be damaged due to the dangling,
motion or accidental pulling of the cables or can cause a malfunction due to a
cable connection fault.
When unplugging the cable connected to the unit, do not hold and pull from
the cable portion.
Doing so can cause the unit or cable to be damaged or can cause a
malfunction due to a cable connection fault.
Do not drop the module or subject it to strong shock.
A module damage may result.
Do not drop or give an impact to the battery mounted to the unit.
Doing so may damage the battery, causing the battery fluid to leak inside the
battery.
If the battery is dropped or given an impact, dispose of it without using.
Before touching the unit, always touch grounded metals, etc. to discharge
static electricity from human body, etc.
Not doing so can cause the unit to fail or malfunction.
Use the battery manufactured by Mitsubishi Electric Corporation.
Use of other batteries may cause a risk of fire or explosion.
Dispose of used battery promptly.
Keep away from children.
Do not disassemble and do not dispose of in fire.
Be sure to shut off all phases of the external power supply before replacing
the battery or using the dip switch of the terminating resistor.
Not doing so can cause the unit to fail or malfunction by static electricity.
WARNING
CAUTION
WARNING
WARNING
CAUTION
[TOUCH PANEL PRECAUTIONS]
[PRECAUTIONS WHEN THE DATA STORAGE IS IN USE]
[PRECAUTIONS FOR USE]
[PRECAUTIONS FOR REMOTE CONTROL]
[PRECAUTIONS FOR EXCLUSIVE AUTHORIZATION CONTROL]
[DISPOSAL PRECAUTIONS]
For the analog-resistive film type touch panels, normally the adjustment is not
required.
However, the difference between a touched position and the object position
may occur as the period of use elapses.
When any difference between a touched position and the object position
occurs, execute the touch panel calibration.
When any difference between a touched position and the object position
occurs, other object may be activated.
This may cause an unexpected operation due to incorrect output or
malfunction.
If the SD card is removed from drive A of the GOT while being accessed by
the GOT, the GOT may stop processing data for about 20 seconds.
The GOT cannot be operated during this period.
The functions that run in the background including a screen updating, alarm,
logging, scripts, and others are also interrupted.
Since this interruption makes an impact to the system operation, it might
cause failure.
Check that the SD card access LED is off before removing the SD card.
If the data storage is removed from the GOT while being accessed by the
GOT, the data storage and files may be damaged.
Before removing the data storage from the GOT, check the SD card access
LED, system signal, or others to make sure that the data storage is not
accessed.
Turning off the GOT while it accesses the SD card results in damage to the
SD card and files.
After inserting an SD card into the GOT, make sure to close the SD card
cover.
Not doing so causes the data not to be read or written.
When removing the SD card from the GOT, make sure to support the SD card
by hand as it may pop out.
Not doing so may cause the SD card to drop from the GOT, resulting in a
failure or break.
When inserting a USB device into a USB interface of the GOT, make sure to
insert the device into the interface firmly.
Not doing so can cause a malfunction due to a contact failure.
Before removing the data storage from the GOT, follow the procedure for
removal on the utility screen of the GOT.
After the successful completion dialog is displayed, remove the data storage
by hand carefully.
Not doing so may cause the data storage to drop from the GOT, resulting in a
failure or break.
Do not touch the outer edge of the actual display area repeatedly.
Doing so may result in a failure.
Do not turn off the GOT while data is being written to the storage memory
(ROM) or SD card.
Doing so may corrupt the data, rendering the GOT inoperative.
Remote control is available through a network by using GOT functions,
including the SoftGOT-GOT link function, the remote personal computer
operation function, the VNC server function, and the GOT Mobile function.
If these functions are used to perform remote control of control equipment,
the field operator may not notice the remote control, possibly leading to an
accident.
In addition, a communication delay or interruption may occur depending on
the network environment, and remote control of control equipment cannot be
performed normally in some cases.
Before using the above functions to perform remote control, fully grasp the
circumstances of the field site and ensure safety.
Make sure to fully understand the GOT network interaction function before
using this function to control the authorization among pieces of equipment to
prevent simultaneous operations.
The exclusive authorization control of the GOT network interaction function
can be enabled or disabled for each screen.
(For all screens, the exclusive authorization control is disabled by default.)
Properly determine the screens for which the exclusive authorization control
is required, and set the control by screen.
A screen for which the exclusive authorization control is disabled can be
operated simultaneously from pieces of equipment.
Make sure to determine the operation period for each operator, fully grasp the
circumstances of the field site, and ensure safety to perform operations.
When disposing of this product, treat it as industrial waste.
When disposing of batteries, separate them from other wastes according to
the local regulations.
(Refer to the GOT2000 Series User’s Manual (Hardware) for details of the
battery directive in the EU member states.)
CAUTION
WARNING
CAUTION
CAUTION
WARNING
WARNING
CAUTION
[TRANSPORTATION PRECAUTIONS]
Manuals
The following shows manuals relevant to this product.
For detailed manuals and relevant manuals, refer to the e-Manual or PDF
manuals stored in the DVD-ROM for the screen design software used.
The latest manuals are also available from MITSUBISHI ELECTRIC FA Global
Website (www.MitsubishiElectric.com/fa).
Compliance with the new China RoHS directive
GOT 相关的基于 电器电子产品有害物质限制使用管理办 要求的表示方法
含有有害 6 物质的名称、含有量、含有部件
本产品中所含有的有害 6 质的名称、含有量、含有部件如下表所示。
产品中有害物质的名称及含量
本表格依据 SJ/T11364 的规定编制。
: 表示该有害物质在该部件所有均质材料中的含量均在 GB/T26572 定的限量要
求以下。
× : 表示该有害物质至少在该部件的某一均质材料中的含量超出 GB/T26572 规定
限量要求。
Referenced Standard: GB/T15969.2
(Requirement of Chinese standardized law)
Before using the GOT
Connect the connector of the GOT to the connector of the battery.
Refer to the GOT2000 Series User’s Manual (Hardware) for the connection
instructions.
For details on the GOT specifications, installing instructions, wiring, maintenance
and inspection, or checking procedure for the version and the compatible standard,
refer to the GOT2000 Series User’s Manual (Hardware).
Packing List
The GOT product package includes the following:
When transporting lithium batteries, make sure to treat them based on the
transport regulations.
(Refer to the GOT2000 Series User’s Manual (Hardware) for details of the
regulated models.)
Make sure to transport the GOT main unit and/or relevant unit(s) in the
manner they will not be exposed to the impact exceeding the impact
resistance described in the general specifications of this manual, as they are
precision devices.
Failure to do so may cause the unit to fail.
Check if the unit operates correctly after transportation.
When fumigants that contain halogen materials such as fluorine, chlorine,
bromine, and iodine are used for disinfecting and protecting wooden
packaging from insects, they cause malfunction when entering our products.
Please take necessary precautions to ensure that remaining materials from
fumigant do not enter our products, or treat packaging with methods other
than fumigation (heat method).
Additionally, disinfect and protect wood from insects before packing products.
Manual name Manual number (Model code)
GOT2000 Series User’s Manual (Hardware)
SH-081194ENG (1D7MJ5)
GOT2000 Series User’s Manual (Utility)
SH-081195ENG (1D7MJ6)
Note: This symbol mark is for China only.
部件名称
有害物质
(Pb)
(Hg)
(Cd)
六价铬
(Cr(VI))
多溴联苯
(PBB)
多溴二苯醚
(PBDE)
电路板组件 ×
树脂壳体、电缆、膜材
钣金部件、螺丝等金属部件 ×
Description Quantity
GT25 Wide Model 1
Battery (GT11-50BAT) (Attached to the GOT) 1
Installation fitting 4
GT25 Wide Model General Description (This manual) 1
1
CAUTION
1. FEATURES
(1) Abundant standard equipment
Variety of connection with FA devices
SD card interface compatible with the SDHC card having a large capacity
and allowing high-speed communication
Connection with various peripheral devices with the USB host
One sound output interface
Two Ethernet interfaces
(2) Improved usability
Abundant troubleshooting
Easy and clear screen creation
PC-like operation screen
Support for the vertical installation
(3) Enhanced compatibility with Mitsubishi Electric FA devices
(4) LED backlight
2. Part Names and Settings
The following shows the part names of GT2512, GT2510, and GT2507.
No. Name Description
1) Display screen Displays the utility and the user-created screen.
2) Touch panel
For operating the touch switches in the utility and the user-
created screen
3)
USB interface (Device
/Front face)
For connecting a personal computer (Connector shape:
Mini-B)
mark:
*1
4) POWER LED
Lit in blue : Power is properly supplied.
Lit in orange : Screen saving
Blinks in orange/blue : Backlight failure
Not lit : Power is not supplied
5) Unit installation fitting Mounting fixtures for fixing the GOT to the control panel
6) Reset switch Hardware reset switch
GT2512
14)
8)
9)
10)
3)
4)
1)2) 5) 5)6)7)
11)12) 23)
15)
13)
18)21)
20)
22) 17)19)
16)
24)
5) 5)
GT2510
1)2)
3)
21)
14)
15)
20)
18)19) 17)
5)
5)
5)
5)
4)
7)
23)
10)
8)
11)12)
9)
6)
22)
16)
13)
24)
GT2507
1)2)
3)
21)
14)
15)
20)
18)19) 17)
5)
5)
5)
5)
4)
7)
23)
10)
8)
11)12)
9)
6)
22)
16)
13)
24)
*1: After the successful completion dialog is displayed, remove the USB cable by
hand carefully.
When closing the USB environmental protection cover, fix the cover to the GOT
by pushing the USB mark on the latch firmly to comply with the protective
structure.
*2: To replace the battery, leave the GOT on for more than 10 minutes before
replacing the battery.
Replace the battery within 5 minutes.
Be sure to use GT11-50BAT. Risk of explosion if battery is replaced by an
incorrect type.
Dispose of used batteries according to the instructions.
*3: Use copper conductors only.
3. Specifications
3.1 General Specifications
7) Installation switch Used for OS installations at the GOT startup
8) SD card access LED
Lit: SD card mounted
Blinking: SC card accessed
No lit: SD card not mounted or SD card mounted
(removable)
9) SD card interface For installing a SD card
10) SD card cover
With a switching function for accepting and stopping the
access to the SD card
When the cover is opened : Access is prohibited
When the cover is closed : Access is allowed
11) Battery holder Houses the battery
12)
Terminating resistor
setting switch
(Inside cover)
For switching on and off of the terminating resistor for the
RS-422/485 communication port (Default (Off))
13)
Wireless LAN
communication unit
interface
For installing a communication unit
14)
USB interface
(Host/Back face)
For connecting a USB mouse, a USB keyboard, or a USB
barcode reader, and transferring or saving data
(Connector shape: TYPE-A)
15)
Hole for attaching a
cable clamp
For attaching a cable clamp to prevent the USB cable or the
sound output cable from being accidentally pulled out
(Recommended product: SKB-132PWD of SK KOHKI CO.,
LTD. or corresponding product)
16)
Vertical installation
arrow mark
For the vertical installation, install the GOT so that the arrow
points upward.
17) Power terminal Power input terminal, FG terminal
18)
Ethernet interface
(port 1)
For communicating with a controller or connecting a
personal computer (Connector shape: RJ-45 (modular
jack))
19)
Ethernet interface
(port 2)
20)
Ethernet
communication status
LED
SD/RD LED ON : Data sent or received
SD/RD LED OFF: Data not sent or received
SPEED LED ON : Communicating at 100 Mbps
SPEED LED OFF: Communicating at 10 Mbps or
disconnected
21) RS-422/485 interface
For communicating with a controller (Connector shape: D
sub 9-pin (female))
22) RS-232 interface
For communicating with a controller (Connector shape: D
sub 9-pin (male))
23) Sound output interface
For outputting sounds (applicable plug: Φ3.5 stereo mini-
plug (3-prong))
24) Rating plate mark:
*2 *3
Item Specifications
Operating ambient
temperature
*1
Température ambiante
de fonctionnement
*1
0 to 55
*5
0 à 55
*5
Storage ambient
temperature
-20 to 60
Operating ambient
humidity
10 to 90% RH, non-condensing
Storage ambient
humidity
10 to 90% RH, non-condensing
Vibration
resistance
Compliant
with JIS B
3502 and
IEC 61131-
2
Frequency
Acceleration
Half-
amplitude
Sweep
count
Under
intermittent
vibration
5 to
8.4 Hz
-
3.5 mm
10 times
each in X, Y
and Z
directions
8.4
to
150 Hz
9.8 m/s
2
-
Under
continuous
vibration
5 to
8.4 Hz
-
1.75 mm
-
8.4
to
150 Hz
4.9 m/s
2
-
Shock resistance
Compliant with JIS B 3502 and IEC 61131-2 147 m/s
2
(15G),
3 times each in X, Y and Z directions
No. Name Description
*1: The operating ambient temperature includes the temperature inside the
enclosure of the control panel to which the GOT is installed.
La température ambiante de fonctionnement inclut la température à l'intérieur
du boîtier du tableau de commande sur lequel le GOT est installé.
*2: Do not use or store the GOT under pressure higher than the atmospheric
pressure of altitude 0 m (0ft.).
Failure to observe this instruction may cause a malfunction.
When an air purge is made inside the control panel by adding pressure, there
may be a clearance between the surface sheet and the screen making it difficult
to use the touch panel, or the sheet may come off.
*3: This indicates the section of the power supply to which the equipment is
assumed to be connected between the public electrical power distribution
network and the machinery within the premises.
Category II applies to equipment for which electrical power is supplied from
fixed facilities.
The surge voltage withstand level for up to the rated voltage of 300 V is 2500 V.
*4: This index indicates the degree to which conductive material is generated in the
environment where the equipment is used.
In pollution degree 2, only non-conductive pollution occurs but temporary
conductivity may be produced due to condensation.
*5: When a protective cover for oil is mounted on the GOT, the maximum operating
ambient temperature must be 5°C lower than the one described above.
Lors de l'installation du couvercle de protection contre l’huile, la température
ambiante de fonctionnement doit être réduite de 5°C par rapport aux valeurs
maximales dans les spécifications générales.
3.2 Power Supply Specifications
The following indicates the power supply specifications for GT25 wide model.
Operating atmosphere
No greasy fumes, corrosive gas, flammable gas, excessive
conductive dust, and direct sunlight (Same as storage atmosphere)
Operating altitude
*2
2000 m (6562 ft) max.
Installation location Inside control panel (Indoor use)
Overvoltage category
*3
II or less
Pollution degree
*4
2 or less
Cooling method Self-cooling
Grounding
Grounding with a ground resistance of 100 Ω or less by using a
ground cable that has a cross-sectional area of 2 mm
2
or more. If
impossible, connect the ground cable to the control panel.
Point
Refer to the GOT2000 Series User’s Manual (Hardware) for details on the performance
specifications of each GOT.
Note
Operation at momentary failure
If an instantaneous power failure occurs in the power supply and continues for more
than the permissible period, the GOT will be reset.
Make sure to power on the unit more than 5 seconds after power-off.
Item
Specifications
GT2512-WXTSD
GT2512-WXTBD
GT2510-WXTSD
GT2510-WXTBD
GT2507-WTSD
GT2507-WTBD
Power supply voltage DC24V (+25%, -20%)
Power
consumption
maximum load 20 W or less 16 W or less
Stand alone 14W 9 W
Stand alone with
backlight off
8W 5 W
Inrush current
59 A or less (2 ms, operating ambient temperature 25,
maximum load)
Allowable momentary power
failure time
5 ms or less
Noise immunity
500 Vp-p noise voltage, 1 s noise width (when
measuring with a noise simulator under 25 to 60 Hz
noise frequency)
Dielectric withstand voltage 350 VAC for 1 minute across power terminals and earth
Insulation resistance
10 M or more across power terminals and earth by a 500
V DC insulation resistance tester
Applicable wire size 0.75[mm
2
] to 2[mm
2
] (14 to 18 AWG)
Applicable solderless terminal
Solderless terminal for M3 screw RAV1.25-3, V2-S3.3,
V2-N3A, FV2-N3A
Applicable tightening torque
(Terminal block terminal screw)
0.5[N•m] to 0.8[N•m]
Item Specifications
3.3 External Dimensions
GT2507
142(5.59)
180(7.09)
142(5.59)
133(5.24)
48(1.89)
48(1.89)
6
GT2510
194(7.64)
185(7.28) 10 10
6
243(9.57)
10 10
203(7.99)
252(9.92)
145(5.71)
189(7.44)
GT2512
230(9.06)
299(11.77)
219(8.62)
210(8.27) 1010
48(1.89)
6
290(11.42)
35
230(9.06)
Unit : mm (inch)
(0.39)
(0.39) (0.39) (0.39) (0.39)
(0.24)
(0.24)
(0.96)
(0.39)
(0.24)
24.5
203(7.99)
(1.38)
4. EMC DIRECTIVE
For the products sold in European countries, the conformance to the
EMC Directive, which is one of the European Directives, has been a
legal obligation since 1996. Also, conformance to the Low Voltage.
Directive, another European Directives, has been a legal obligation since
1997.
Manufacturers who recognize their products must conform to the EMC
and Low Voltage Directive are required to declare that their products
conform to these Directives and put a "CE mark" on their products.
Authorized representative in Europe
Authorized representative in Europe is shown below.
Name :Mitsubishi Electric Europe BV
Address :Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany
4.1 Requirements to Meet EMC Directive
EMC Directives are those which require "any strong electromagnetic
force is not output to the external.:Emission (electromagnetic
interference)" and "It is not influenced by the electromagnetic wave from
the external.: Immunity (electromagnetic sensitivity)".
Items4.1.1 through4.1.3 summarize the precautions to use GOT and
configure the mechanical unit in order to match the EMC directives.
Though the data described herein are produced with our best on the
basis of the requirement items and standards of the restrictions gathered
by Mitsubishi Electric, they do not completely guaranteed that all
mechanical unit manufactured according to the data do not always
match the above.
4.1.1 EMC directive
The standards of the EMC Directive are shown below.
*1: The GOT is an open type device (device installed to another device) and must
be installed in a conductive control panel.
The above test items are conducted in the condition where the GOT is installed
on the conductive control panel and combined with the Mitsubishi Electric PLC.
*2: When using the sound output cable, the cable length must be 30 m (1181.1 in.)
or shorter.
*3: QP (Quasi-Peak): Quasi-peak value, Mean: Average value
*4: The above test items are conducted in the following conditions.
30 M-230 MHz QP : 40 dB V/m (10m in measurement range)
230 M-1000 MHz QP : 47 dB V/m (10m in measurement range)
Applied
standard
Test standard Test details Standard value
EN61131-2
: 2007
CISPR16-2-3
Radiated noise
*1, *2
Electromagnetic
emissions from the
product are
measured.
30 M-230 MHz QP:
30 dB V/m (30 m in
measurement range)
*3, *4
230 M-1000 MHz QP:
37 dB V/m(30 m in
measurement range)
*3, *4
IEC61000-4-2
Electrostatic
immunity
*1, *2
Immunity test in
which static
electricity is applied
to the cabinet of the
equipment.
4 kV Contact discharge
8 kV Aerial discharge
IEC61000-4-3
Radiated
electromagnetic
field AM
modulation
*1, *2
Immunity test in
which field is
irradiated to the
product.
80-1000 MHz: 10 V/m
1.4-2 GHz: 3 V/m
2.0-2.7 GHz: 1 V/m
80%AM modulation@1 kHz
IEC61000-4-4
Fast transient burst
noise
*1, *2
Immunity test in
which burst noise is
applied to the power
line and signal lines.
Power line: 2 kV
Digital I/O: 1 kV
Analog I/O: 1 kV
Signal lines: 1 kV
IEC61000-4-5
Surge immunity
*1, *2
Immunity test in
which lightening
surge is applied to
the product.
DC power type
Power line (between line and
ground) : 0.5 kV
Power line (between lines)
: 0.5 kV
Data communication port
: 1 kV
IEC61000-4-6
Conducted RF
immunity
*1, *2
Immunity test in
which a noise
inducted on the
power and signal
lines is applied.
Power line: 10 V
Data communication port: 10 V
IEC61000-4-8
Power supply
frequency magnetic
field immunity
*1, *2
Test for checking
normal operations
under the
circumstance
exposed to the
ferromagnetic field
noise of the power
supply frequency
(50/60 Hz).
30 A/m
4.1.2 Control panel
The GOT is an open type device (device installed to another device) and
must be installed in a conductive control panel.
It not only assure the safety but also has a large effect to shut down the
noise generated from GOT, on the control panel.
(1) Control Panel
(a) The control panel must be conductive.
(b) When fixing a top or bottom plate of the control panel with bolts,
do not coat the plate and bolt surfaces so that they will come into
contact.
And connect the door and box using a thick grounding cable in
order to ensure the low impedance under high frequency.
(c) When using an inner plate to ensure electric conductivity with the
control panel, do not coat the fixing bolt area of the inner plate
and control panel to ensure conductivity in the largest area as
possible.
(d) Ground the control panel using a thick grounding cable in order to
ensure the low impedance under high frequency.
(e) The diameter of cable holes in the control panel must be 10 cm
(3.94 in.). In order to reduce the chance of radio waves leaking
out, ensure that the space between the control panel and its door
is small as possible.
Paste the EMI gasket directly on the painted surface to seal the
space so that the leak of electric wave can be suppressed.
Our test has been carried out on a panel having the damping
characteristics of 37 dB max. and 30dB mean (measured by 3 m
method with 30 to 300 MHz).
(2) Connection of power and ground wires
Ground and power supply wires for the GOT must be connected as
described below.
(a) Provide a ground point near the GOT. Short-circuit the FG
terminal of the GOT, and ground it with the thickest and shortest
cable possible. (The cable length must be 30 cm (11.81 in.) or
shorter.)
The FG terminal function is to pass the noise generated in the PC
system to the ground, so an impedance that is as low as possible
must be ensured. As the wires are used to relieve the noise, the
wire itself carries a large noise content and thus short wiring
means that the wire is prevented from acting as an antenna.
Note) A long conductor will become a more efficient antenna at
high frequency.
(b) The earth wire led from the earthing point must be twisted with
the power supply wires.
By twisting with the earthing wire, noise flowing from the power
supply wires can be relieved to the earthing. However, if a filter is
installed on the power supply wires, the wires and the earthing
wire may not need to be twisted.
4.1.3 Noise filter (power supply line filter)
The noise filter (power supply line filter) is a device effective to reduce
conducted noise. Except some models, installation of a noise filter onto
the power supply lines is not necessary. However conducted noise can
be reduced if it is installed. (The noise filter is generally effective for
reducing conducted noise in the band of 10 MHz or less.) Usage of the
following filters is recommended.
The precautions required when installing a noise filter are described
below.
(1) Do not install the input and output cables of the noise filter together to
prevent the output side noise will be inducted into the input side
cable where noise has been eliminated by the noise filer.
(2) Connect the noise filter's ground terminal to the control panel with the
shortest cable as possible (approx. 10 cm (3.94 in.) or less).
Model name FN343-3/05 FN660-6/06 RSHN-2003
Manufacturer SCHAFFNER SCHAFFNER TDK
Rated current 3 A 6 A 3 A
Rated voltage 250 V
Installing the input and output cables
together will cause noise induction.
Separate the input cable from the output
cable.
Filter
Induction
Output side
(device side)
Input side
(power supply side)
Filter
Output side
(device side)
Input side
(power supply side)
5. INSTALLATION
5.1 Control Panel Inside Dimensions for
Mounting GOT
Install the GOT on the control panel out of the way for the equipment
inside the control panel. Do not install the GOT and the unit in
prohibited areas for the installation.
5.2 Panel Cutting Dimensions
5.3 Mounting Position
When mounting the GOT, the following clearances must be maintained
from other structures and devices.
Some cables may need to be longer than the specified dimensions when
connecting to the GOT.
Therefore, consider the connector dimensions and bending radius of the
cable as well for installation.
For the lead-in allowance for cables at the bottom of the GOT, refer to
the GOT2000 Series User’s Manual (Hardware) .
For the vertical installation, install the GOT so that the vertical installation
arrow printed on the GOT rear face points upward.
According to the dimensions in the following table, leave clearances
between the GOT and the other devices. The values enclosed in
square brackets apply to the case where no other equipment
generating radiated noise (such as a contactor) or heat is installed
near the GOT. However, keep the ambient temperature of the GOT
to 55 °C or lower.
Unit: mm(inch)
*1: When opening or closing the battery cover: 72(2.83) or more
Point
Applicable cable
Some cables may need to be longer than the specified dimensions when connecting to the
GOT. Therefore, consider the connector dimensions and bending radius of the cable as
well for installation.
Item
GT2512
GT2510
GT2507
A
51(2.01) or more
[23(0.91) or more]
64(2.52) or more
B
Horizontal: 81(3.19) or more
[23(0.91) or more]
Vertical: 53(2.09) or more
[23(0.91) or more]
C
53(2.09) or more
[23(0.91) or more]
53(2.09) or more
[32(1.26) or more]
D
Horizontal: 53(2.09) or more
[23(0.91) or more]
Vertical: 81(3.19) or more
[23(0.91) or more]
E
*1
100(3.94) or more [20(0.79) or more]
Unit: mm (inch)
*Panel thickness : 1.6 to 4 mm
(0.06 to 0.16 inch)
180.5 (7.11)
+1 (0.04)
0 (0)
133.5 (5.26)
+1 (0.04)
0 (0)
243.5 (9.59)
+1 (0.04)
0 (0)
185.5 (7.30)
+1 (0.04)
0 (0)
Horizontal
Vertical
GOT A B
GT2510
GT2512
290.5 (11.44)
+1 (0.04)
0 (0)
210.5 (8.29)
+1 (0.04)
0 (0)
GT2507
B
A
B
A
B
DE
A
C
Panel thickness:
1.6 to 4mm
(0.06 to 0.16 inch)
Panel thickness:
1.6 to 4mm
(0.06 to 0.16 inch)
B
D
E
A
C
Horizontal
Vertical
5.4 Control Panel Inside Temperature and
Installation Angle
When installing the GOT to a panel, set the display section as shown
below.Using the GOT with the installation angle other than the following
deteriorates the GOT earlier.
Installing the GOT horizontally
When installing the GOT with the installation angle between 60 to
105 °, the temperature inside the control panel must be within 55 °C.
When installing the GOT with the installation angle other than
between 60 to 105 °, the temperature inside the control panel must be
within 40 °C.
Installing the GOT vertically
When the GOT is installed a 90 ° angle, the control panel inside
temperature must be within 55 °C. When the GOT is installed at any
angle other than 90°, the control panel inside temperature must be
within 40 °C.
Horizontal Vertical
GOT
Display section
Panel or others
105°
60°
GOT
Display section
Panel or others
90°
5. INSTALLATION
5.1 Dimensions intérieures du tableau de
commande pour le montage du GOT
Installez le GOT sur le tableau de commande en laissant de l'espace
pour le dispositif à l'intérieur du tableau de commande. N'installez
pas le GOT et le module dans des zones où l'installation est interdite.
5.2 Cotes de découpe du panneau
5.3 Position de montage
Lors du montage du GOT, laissez les espaces suivants pour les autres
structures et dispositifs.Certains câbles peuvent être plus longs que les
dimensions spécifiées lors de la connexion au GOT.
Par conséquent, prenez également en compte les dimensions du
connecteur et le rayon de courbure du câble pour l'installation.
Pour connaître l'espace à laisser pour les câbles sous le GOT, référez-
vous au manuel GOT2000 Series User’s Manual (Hardware).
Pour l’installation à la verticale, installez le GOT de sorte que la flèche
d’installation à la verticale imprimée sur la face arrière du GOT pointe
vers le haut.
Laissez les espaces entre le GOT et les autres dispositifs en fonction
des dimensions contenues dans le tableau suivant. Les valeurs entre
parenthèses s'appliquent au cas où aucun dispositif générant des
émissions sonores (comme un contacteur) ou de la chaleur n'est installé
près du GOT.
Toutefois, maintenez la température ambiante du GOT à 55°C ou moins.
Unité: mm (pouce)
*1: Pour ouvrir ou fermer le couvercle de la batterie: 72 (2,83) ou plus
Point
Câble applicable
Certains câbles peuvent être plus longs que les dimensions spécifiées lors de la
connexion au GOT. Par conséquent, prenez également en compte les dimensions du
connecteur et le rayon de courbure du câble pour l'installation.
Article
GT2512
GT2510
GT2507
A
51 (2,01) ou plus
[23 (0,91) ou plus]
64 (2,52) ou plus
B
Horizontal: 81 (3,19) ou plus
[23 (0,91) ou plus]
Vertical: 53 (2,09) ou plus
[23 (0,91) ou plus]
C
53 (2,09) ou plus
[23 (0,91) ou plus]
53 (2,09) ou plus
[32 (1,26) ou plus]
D
Horizontal: 53 (2,09) ou plus
[23 (0,91) ou plus]
Vertical: 81 (3,19) ou plus
[23 (0,91) ou plus]
E
*1
100 (3,94) ou plus [20 (0,79) ou plus]
Unité : mm (pouce)
*
É
paisseur du panneau : 1,6 à 4mm
(0,06 à 0,16 pouce)
180.5 (7.11)
+1 (0.04)
0 (0)
133.5 (5.26)
+1 (0.04)
0 (0)
243.5 (9.59)
+1 (0.04)
0 (0)
185.5 (7.30)
+1 (0.04)
0 (0)
Horizontal
Vertical
GOT A B
GT2510
GT2512
290.5 (11.44)
+1 (0.04)
0 (0
210.5 (8.29)
+1 (0.04)
0 (0
GT2507
B
A
B
A
B
DE
A
C
Épaisseur du panneau :
1,6 à 4mm
(0,06 à 0,16 pouce) Épaisseur du panneau :
1,6 à 4mm
(0,06 à 0,16 pouce)
B
D
E
A
C
Vertical
Horizontal
5.4 Température intérieure et angle
d'installation du tableau de commande
Lors de l'installation du GOT sur un panneau, réglez la zone d'affichage
comme indiqué ci-dessous.
Si l'angle d'installation est différent de celui indiqué, le GOT se détériore
plus tôt.
Installation du GOT à l’horizontale
Lors de l'installation du GOT avec un angle d'installation compris entre
60 et 105°, la température à l'intérieur du tableau de commande doit
être d'environ 55°C. Lors de l'installation du GOT avec un angle
d'installation non compris entre 60 et 105°, la température à l'intérieur
du tableau de commande doit être d'environ 40°C.
Installation du GOT à la verticale
Lors de l’installation du GOT avec un angle de 90°, la température à
l’intérieur du panneau de commande ne doit pas dépasser 55°C. Lors
de l’installation du GOT avec tout autre angle que 90°, la température
à l’intérieur du panneau de commande ne doit pas dépasser 40°C.
Horizontal Vertical
6. MAINTENANCE AND INSPECTION
Refer to the GOT2000 Series User’s Manual (Hardware) for
maintenance and inspection for the GOT.
GOT
Zone d'affichage
Tableau ou autres
105°
60°
90°
Zone d'affichage
GOT
Tableau ou autres
Warranty
Mitsubishi Electric will not be held liable for damage caused by
factors found not to be the cause of Mitsubishi Electric; machine
damage or lost profits caused by faults in the Mitsubishi Electric
products; damage, secondary damage, accident compensation
caused by special factors unpredictable by Mitsubishi Electric;
damages to products other than Mitsubishi Electric products; and to
other duties.
For safe use
This product has been manufactured as a general-purpose part for
general industries, and has not been designed or manufactured to
be incorporated in a device or system used in purposes related to
human life.
Before using the product for special purposes such as nuclear
power, electric power, aerospace, medicine or passenger
movement vehicles, consult with Mitsubishi Electric.
This product has been manufactured under strict quality control.
However, when installing the product where major accidents or
losses could occur if the product fails, install appropriate backup or
failsafe functions in the system.
Country/Region Sales office/Tel
USA Mitsubishi Electric Automation, Inc.
500 Corporate Woods Parkway, Vernon Hills, IL 60061, U.S.A.
Tel: +1-847-478-2100
Brazil Mitsubishi Electric do Brasil Comercio e Servicos Ltda.
Avenida Adelino Cardana, 293, 21 andar, Bethaville, Barueri SP, Brazil
Tel: +55-11-4689-3000
Mexico Mitsubishi Electric Automation, Inc. Mexico Branch
Boulevard Miguel de Cervantes Saavedra 301, Torre Norte Piso 5, Ampliacion Granada,
Miguel Hidalgo, Ciudad de Mexico, Mexico, C.P.11520
Tel: +52-55-3067-7512
Germany Mitsubishi Electric Europe B.V. German Branch
Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany
Tel: +49-2102-486-0
UK Mitsubishi Electric Europe B.V. UK Branch
Travellers Lane, UK-Hatfield, Hertfordshire, AL10 8XB, U.K.
Tel: +44-1707-28-8780
Italy Mitsubishi Electric Europe B.V. Italian Branch
Centro Direzionale Colleoni - Palazzo Sirio, Viale Colleoni 7,
20864 Agrate Brianza (MB), Italy
Tel: +39-039-60531
Spain Mitsubishi Electric Europe B.V. Spanish Branch
Carretera de Rubi, 76-80-Apdo. 420, E-08190 Sant Cugat del Valles (Barcelona), Spain
Tel: +34-935-65-3131
France Mitsubishi Electric Europe B.V. French Branch
25, Boulevard des Bouvets, 92741 Nanterre Cedex, France
Tel: +33-1-55-68-55-68
Czech Mitsubishi Electric Europe B.V. Czech Branch
Pekarska 621/7, 155 00 Praha 5, Czech Republic
Tel: +420-255 719 200
Turkey Mitsubishi Electric Turkey A.S. Umraniye Branch
Serifali Mahallesi Nutuk Sokak No:5, TR-34775 Umraniye / Istanbul, Turkey
Tel: +90-216-526-3990
Poland Mitsubishi Electric Europe B.V. Polish Branch
ul. Krakowska 48, 32-083 Balice, Poland
Tel: +48-12-347-65-00
Russia Mitsubishi Electric (Russia) LLC St. Petersburg Branch
Piskarevsky pr. 2, bld 2, lit "Sch", BC "Benua", office 720; 195027 St. Petersburg, Russia
Tel: +7-812-633-3497
South Africa Adroit Technologies
20 Waterford Office Park, 189 Witkoppen Road, Fourways, South Africa
Tel: +27-11-658-8100
China Mitsubishi Electric Automation (China) Ltd.
Mitsubishi Electric Automation Center, No.1386 Hongqiao Road, Shanghai, China
Tel: +86-21-2322-3030
Taiwan SETSUYO ENTERPRISE CO., LTD.
6F, No.105, Wugong 3rd Road, Wugu District, New Taipei City 24889, Taiwan
Tel: +886-2-2299-2499
Korea Mitsubishi Electric Automation Korea Co., Ltd.
7F to 9F, Gangseo Hangang Xi-tower A, 401, Yangcheon-ro, Gangseo-Gu,
Seoul 07528, Korea
Tel: +82-2-3660-9569
Singapore Mitsubishi Electric Asia Pte. Ltd.
307 Alexandra Road, Mitsubishi Electric Building, Singapore 159943
Tel: +65-6473-2308
Thailand Mitsubishi Electric Factory Automation (Thailand) Co., Ltd.
12th Floor, SV.City Building, Office Tower 1, No. 896/19 and 20 Rama 3 Road,
Kwaeng Bangpongpang, Khet Yannawa, Bangkok 10120, Thailand
Tel: +66-2682-6522 to 31
Indonesia PT. Mitsubishi Electric Indonesia
Gedung Jaya 8th Floor, JL. MH. Thamrin No.12, Jakarta Pusat 10340, Indonesia
Tel: +62-21 3192-6461
Vietnam Mitsubishi Electric Vietnam Company Limited
11th & 12th Floor, Viettel Tower B, 285 Cach Mang Thang 8 Street, Ward 12,
District 10, Ho Chi Minh City, Vietnam.
Tel: +84-28-3910-5945
India Mitsubishi Electric India Pvt. Ltd. Pune Branch
Emerald House, EL-3, J Block, M.I.D.C., Bhosari, Pune - 411026, Maharashtra, India
Tel: +91-20-2710-2000
Australia MITSUBISHI ELECTRIC AUSTRALIA PTY. LTD.
348 Victoria Road, P.O. Box 11, Rydalmere, N.S.W 2116, Australia
Tel: +61-2-9684-7777
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
When exported from Japan, this manual does not require application to the Ministry
of Economy, Trade and Industry for service transaction permission.
Specifications subject to change without notice.
Printed in Japan, January 2021.