GT27 General Description
Thank you for choosing Mitsubishi Electric Graphic Operation
Terminal (GOT).
© 2013 MITSUBISHI ELECTRIC CORPORATION
GT2715-XTBA
GT2712-STBD
GT2710-VTBA
GT2708-STBA
GT2705-VTBD
GT2715-XTBD
GT2712-STWD
GT2710-VTWA
GT2708-STBD
GT2712-STBA
GT2710-STBA
GT2710-VTBD
GT2708-VTBA
GT2712-STWA
GT2710-STBD
GT2710-VTWD
GT2708-VTBD
Prior to use, please read both this manual and the
detailed manual thoroughly to fully understand the
product.
MODEL GT27-U-GD-E
Model
code
1D7MI3
IB(NA)-0800502ENG-M(2102)MEE
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
SAFETY PRECAUTIONS
(Always read these precautions before using this equipment.)
Before using this product, please read this manual and the relevant
manuals introduced in this manual carefully and pay full attention to
safety to handle the product correctly.
The precautions given in this manual are concerned with this prod-
uct.
In this manual, the safety precautions are ranked as "WARNING"
and "CAUTION".
Note that the CAUTION level may lead to a serious accident
according to the circumstances.
Always follow the instructions of both levels because they are import-
ant to personal safety.
Please save this manual to make it accessible when required and
always forward it to the end user.
[DESIGN PRECAUTIONS]
Indicates that incorrect handling may cause
hazardous conditions, resulting in death or
severe injury.
Indicates that incorrect handling may cause
hazardous conditions, resulting in medium or
slight personal injury or physical damage.
Some failures of the GOT, communication unit or cable may keep the outputs
on or off.
Some failures of a touch panel may cause malfunction of the input objects
such as a touch switch.
An external monitoring circuit should be provided to check for output signals
which may lead to a serious accident.
Not doing so can cause an accident due to false output or malfunction.
Do not use the GOT as the warning device that may cause a serious
accident.
An independent and redundant hardware or mechanical interlock is required
to configure the device that displays and outputs serious warning.
Failure to observe this instruction may result in an accident due to incorrect
output or malfunction.
The GOT backlight failure disables the operation on the touch switch(s).
When the GOT backlight has a failure, the POWER LED blinks (orange/blue),
the display section dims, and inputs by a touch switch are disabled.
The display section of the GOT is an analog-resistive type touch panel. The
GOT is multi-touch compliant; however, do not touch three points or more
simultaneously on the display section. Doing so may cause an accident due
to incorrect output or malfunction.
When programs or parameters of the controller (such as a PLC) that is
monitored by the GOT are changed, be sure to reset the GOT, or turn on the
unit again after shutting off the power as soon as possible.
Not doing so can cause an accident due to false output or malfunction.
If a communication fault (including cable disconnection) occurs during
monitoring on the GOT, communication between the GOT and PLC CPU is
suspended and the GOT becomes inoperative.
For bus connection : The PLC CPU becomes faulty and the GOT becomes
inoperative.
For other than bus connection : The GOT becomes inoperative.
A system where the GOT is used should be configured to perform any
significant operation to the system by using the switches of a device other
than the GOT on the assumption that a GOT communication fault will occur.
Not doing so can cause an accident due to false output or malfunction.
[MOUNTING PRECAUTIONS]
To maintain the security (confidentiality, integrity, and availability) of the GOT
and the system against unauthorized access, DoS
*1
attacks, computer
viruses, and other cyberattacks from unreliable networks and devices via
network, take appropriate measures such as firewalls, virtual private
networks (VPNs), and antivirus solutions.
Mitsubishi Electric shall have no responsibility or liability for any problems
involving GOT trouble and system trouble by unauthorized access, DoS
attacks, computer viruses, and other cyberattacks.
*1 DoS: A denial-of-service (DoS) attack disrupts services by overloading
systems or exploiting vulnerabilities, resulting in a denial-of-service (DoS)
state.
Products with the Cl.I, DIV.2 mark on the rating plate are suitable for use in
Class I, Division 2, Groups A, B, C and D hazardous locations, or
nonhazardous locations only.
This mark indicates that the product is certified for use in the Class I,
Division2 environment where flammable gases, vapors, or liquids are not
likely to exist under normal conditions.
When using the products in the Class I, Division 2 environment, observe the
following to reduce the risk of explosion.
• This device is open-type and is to be installed in an enclosure suitable for
the environment and require a tool or key to open.
• Warning - Explosion Hazard - Substitution of any component may impair
suitability for Class I, Division 2.
• Warning - Explosion Hazard - Do not connect or disconnect equipment or
disconnect external connection terminals unless power has been removed or
the area is known to be non-hazardous.
•The side interface, extension interface, and auxiliary extension interface
of this equipment cannot be used in Class I, Division 2 environments.
Les produits marqués Cl.I, DIV.2 sur la plaque signalétique peuvent être
utilisés en Class I, Division 2, local dangereux de groupe A, B, C et D, ou
uniquement en local non dangereux.
Ce logo indique que le produit est homologué pour utilisation en
environnement de Class I, Division 2 où, dans des circonstances anormales,
il peut y avoir présence de gaz, vapeurs ou liquides inflammables.
Si le produit est utilisé en environnement de Class I, Division 2, observer les
précautions suivantes pour réduire le risque d'explosion.
• Cet appareil est de type ouvert et il doit être installé dans une enceinte
appropriée à l'environnement et ne pouvant être ouverte qu'au moyen
d'une clé ou d'un outil.
• Avertissement - Danger d'explosion - Toute substitution de composant
peut compromettre l'aptitude à l'utilisation en Class I, Division 2.
• Avertissement - Danger d'explosion - Ne pas connecter ou déconnecter
l'équipement ni déconnecter les bornes de connexion externes quand le
circuit est sous tension, ni avant de d'être assuré de l'absence d'atmosphère
inflammable.
• L’interface latérale, l’interface d’extension et l’interface d’extension
secondaire de cet équipement ne peuvent être utilisées dans les
environnements de Classe I, Division 2.
Do not bundle the control and communication cables with main-circuit, power
or other wiring.
Run the above cables separately from such wiring and keep them a minimum
of 100mm apart.
Not doing so noise can cause a malfunction.
Do not press the GOT display section with a pointed material as a pen or
driver. Doing so can result in a damage or failure of the display section.
When the GOT connects to an Ethernet network, the IP address setting is
restricted according to the system configuration.
When a GOT2000 series model and a GOT1000 series model are on an
Ethernet network, do not set the IP address 192.168.0.18 for the GOTs and
the controllers on this network.
Doing so can cause IP address duplication at the GOT startup, adversely
affecting the communication of the device with the IP address 192.168.0.18.
The operation at the IP address duplication depends on the devices and the
system.
Turn on the controllers and the network devices to be ready for
communication before they communicate with the GOT.
Failure to do so can cause a communication error on the GOT.
When the GOT is subject to shock or vibration, or some colors appear on the
screen of the GOT, the screen of the GOT might flicker.
Be sure to shut off all phases of the external power supply used by the
system before mounting or removing the GOT main unit to/from the panel.
Not doing so can cause the unit to fail or malfunction.
Be sure to shut off all phases of the external power supply used by the
system before mounting or removing the communication unit or the option
unit onto/from the GOT.
Use the GOT in the environment that satisfies the general specifications
described in this manual. Not doing so can cause an electric shock, fire,
malfunction or product damage or deterioration.
When mounting the GOT to the control panel, tighten the mounting screws in
the specified torque range (0.36 N•m to 0.48 N•m) with a Phillips-head
screwdriver No.2.
Undertightening can cause the GOT to drop, short circuit or malfunction.
Overtightening can cause a drop, short circuit or malfunction due to the
damage of the screws or the unit.
[WIRING PRECAUTIONS]
[TEST OPERATION PRECAUTIONS]
[STARTUP/MAINTENANCE PRECAUTIONS]
When mounting a unit on the GOT, tighten the mounting screws in the
following specified torque range.
When loading the communication unit or option unit other than wireless LAN
unit to the GOT, fit it to the connection interface of the GOT and tighten the
mounting screws in the specified torque range (0.36 N•m to 0.48 N•m) with a
Phillips-head screwdriver No.2.
When loading the wireless LAN unit to the GOT, fit it to the side interface of
GOT and tighten the mounting screws in the specified torque range (0.10
N•m to 0.14 N•m) with a Phillips-head screwdriver No.1.
When the GOT is installed vertically, its side interface is positioned on the
bottom.
To prevent the falling of the wireless LAN communication unit from the side
interface, install or remove the unit while holding it with hands.
Under tightening can cause the GOT to drop, failure or malfunction.
Overtightening can cause a drop, failure or malfunction due to the damage of
the screws or unit.
When closing the USB environmental protection cover, fix the cover to the
GOT by pushing the [PUSH] mark on the latch firmly to comply with the
protective structure.
Remove the protective film of the GOT.
When the user continues using the GOT with the protective film, the film may
not be removed.
In addition, for the models equipped with the human sensor function, using
the GOT with the protective film may cause the human sensor not to function
properly.
Do not operate or store the GOT in the environment exposed to direct
sunlight, high temperature, dust, humidity, or vibrations.
When using the GOT in the environment of oil or chemicals, use the
protective cover for oil.
Failure to do so may cause failure or malfunction due to the oil or chemical
entering into the GOT.
Be sure to shut off all phases of the external power supply used by the
system before wiring.
Failure to do so may result in an electric shock, product damage or
malfunctions.
Make sure to ground the FG terminal and LG terminal of the GOT power
supply section solely for the GOT (ground resistance: 100 Ω or less, ground
cable diameter: 1.6 mm or more).
Not doing so may cause an electric shock or malfunction.
When tightening the terminal screws, use a Phillips-head screwdriver No.2.
Terminal screws which are not to be used must be tightened always at torque
0.5 N•m to 0.8 N•m.
Otherwise there will be a danger of short circuit against the solderless
terminals.
Use applicable solderless terminals and tighten them with the specified
torque.
If any solderless spade terminal is used, it may be disconnected
when the terminal screw comes loose, resulting in failure.
Correctly wire the GOT power supply section after confirming the rated
voltage and terminal arrangement of the product.
Not doing so can cause a fire or failure.
Tighten the terminal screws of the GOT power supply section in the specified
torque range (0.5 N•m to 0.8 N•m). Undertightening can cause a short circuit
or malfunction. Overtightening can cause a short circuit or malfunction due to
the damage of the screws or the unit.
Exercise care to avoid foreign matter such as chips and wire offcuts entering
the GOT.
Not doing so can cause a fire, failure or malfunction.
The module has an ingress prevention label on its top to prevent foreign
matter, such as wire offcuts, from entering the module during wiring.
Do not peel this label during wiring.
Before starting system operation, be sure to peel this label because of heat
dissipation.
Plug the communication cable into the GOT interface or the connector of the
connected unit, and tighten the mounting screws and the terminal screws in
the specified torque range.
Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of
the screws or unit.
Plug the QnA/ACPU/Motion controller (A series) bus connection cable by
inserting it into the connector of the connected unit until it "clicks".
After plugging, check that it has been inserted snugly.
Not doing so can cause a malfunction due to a contact fault.
Before testing the operation of a user-created monitor screen (such as
turning on or off a bit device, changing the current value of a word device,
changing the set value or current value of a timer or counter, and changing
the current value of a buffer memory), thoroughly read the manual to fully
understand the operating procedures.
During the test operation, never change the data of the devices which are
used to perform significant operation for the system.
False output or malfunction can cause an accident.
When power is on, do not touch the terminals.
Doing so can cause an electric shock.
Correctly connect the battery connector.
Do not charge, disassemble, heat, short-circuit, solder, or throw the battery
into the fire. Doing so will cause the battery to produce heat, explode, or
ignite, resulting in injury and fire.
Before starting cleaning or terminal screw retightening, always switch off the
power externally in all phases. Not switching the power off in all phases can
cause a unit failure or malfunction. Undertightening can cause a drop, short
circuit or malfunction. Overtightening can cause a drop, short circuit or
malfunction due to the damage of the screws or unit.
[TOUCH PANEL PRECAUTIONS]
[
PRECAUTIONS WHEN THE DATA STORAGE IS IN USE
]
[PRECAUTIONS FOR USE]
[PRECAUTIONS FOR REMOTE CONTROL]
Do not disassemble or modify the unit.
Doing so can cause a failure, malfunction, injury or fire.
Do not touch the conductive and electronic parts of the unit directly.
Doing so can cause a unit malfunction or failure.
The cables connected to the unit must be run in ducts or clamped.
Not doing so can cause the unit or cable to be damaged due to the dangling,
motion or accidental pulling of the cables or can cause a malfunction due to a
cable connection fault.
When unplugging the cable connected to the unit, do not hold and pull from
the cable portion. Doing so can cause the unit or cable to be damaged or can
cause a malfunction due to a cable connection fault.
Do not drop the module or subject it to strong shock.
A module damage may result.
Do not drop or give an impact to the battery mounted to the unit.
Doing so may damage the battery, causing the battery fluid to leak inside the
battery.
If the battery is dropped or given an impact, dispose of it without using.
Before touching the unit, always touch grounded metals, etc. to discharge
static electricity from human body, etc.
Not doing so can cause the unit to fail or malfunction.
Use the battery manufactured by Mitsubishi Electric Corporation.
Use of other batteries may cause a risk of fire or explosion.
Dispose of used battery promptly.
Keep away from children.
Do not disassemble and do not dispose of in fire.
Be sure to shut off all phases of the external power supply before replacing
the battery or using the dip switch of the terminating resistor.
Not doing so can cause the unit to fail or malfunction by static electricity.
For the analog-resistive film type touch panels, normally the adjustment is not
required.
However, the difference between a touched position and the object position
may occur as the period of use elapses.
When any difference between a touched position and the object position
occurs, execute the touch panel calibration.
When any difference between a touched position and the object position
occurs, other object may be activated.
This may cause an unexpected operation due to incorrect output or
malfunction.
If the SD card is removed from drive A of the GOT while being accessed by
the GOT, the GOT may stop processing data for about 20 seconds.
The GOT cannot be operated during this period.
The functions that run in the background including a screen updating, alarm,
logging, scripts, and others are also interrupted.
Since this interruption makes an impact to the system operation, it might
cause failure.
Check that the SD card access LED is off before removing the SD card.
If the data storage is removed from the GOT while being accessed by the
GOT, the data storage and files may be damaged.
Before removing the data storage from the GOT, check the SD card access
LED, system signal, or others to make sure that the data storage is not
accessed.
Turning off the GOT while it accesses the SD card results in damage to the
SD card and files.
After inserting an SD card into the GOT, make sure to close the SD card
cover.
Not doing so causes the data not to be read or written.
When removing the SD card from the GOT, make sure to support the SD card
by hand as it may pop out.
Not doing so may cause the SD card to drop from the GOT, resulting in a
failure or break.
When inserting a USB device into a USB interface of the GOT, make sure to
insert the device into the interface firmly.
Not doing so can cause a malfunction due to a contact failure.
Before removing the data storage from the GOT, follow the procedure for
removal on the utility screen of the GOT.
After the successful completion dialog is displayed, remove the data storage
by hand carefully.
Not doing so may cause the data storage to drop from the GOT, resulting in a
failure or break.
Do not touch the outer edge of the actual display area repeatedly.
Doing so may result in a failure.
Do not turn off the GOT while data is being written to the storage memory
(ROM) or SD card.
Doing so may corrupt the data, rendering the GOT inoperative.
Remote control is available through a network by using GOT functions,
including the SoftGOT-GOT link function, the remote personal computer
operation function, the VNC server function, and the GOT Mobile function.
If these functions are used to perform remote control of control equipment,
the field operator may not notice the remote control, possibly leading to an
accident.
In addition, a communication delay or interruption may occur depending on
the network environment, and remote control of control equipment cannot be
performed normally in some cases.
Before using the above functions to perform remote control, fully grasp the
circumstances of the field site and ensure safety.
[PRECAUTIONS FOR EXCLUSIVE AUTHORIZATION CONTROL]
[DISPOSAL PRECAUTIONS]
[TRANSPORTATION PRECAUTIONS]
Manuals
The following shows manuals relevant to this product.
For detailed manuals and relevant manuals, refer to the e-Manual or PDF
manuals stored in the DVD-ROM for the screen design software used.
The latest manuals are also available from MITSUBISHI ELECTRIC FA Global
Website (www.MitsubishiElectric.com/fa).
Referenced Standard: GB/T15969.2
(Requirement of Chinese standardized law)
Before using the GOT
Connect the connector of the GOT to the connector of the battery.
Refer to the GOT2000 Series User’s Manual (Hardware) for the connection
instructions.
For details on the GOT specifications, installing instructions, wiring, maintenance
and inspection, or checking procedure for the version and the compatible standard,
refer to the GOT2000 Series User’s Manual (Hardware).
Packing List
The GOT product package includes the following:
1. FEATURES
(1) Abundant standard equipment
• Variety of connection with FA devices
• SD card interface compatible with the SDHC card having a large capacity
and allowing high-speed communication
• Connection with various peripheral devices with the USB host
(2) Improved usability
• Abundant troubleshooting
• Easy and clear screen creation
• PC-like operation screen
• Multi-touch function, Gesture function
• Support for the vertical installation
(3) Enhanced compatibility with Mitsubishi Electric FA devices
(4) Easy replacement
(5) LED backlight
Make sure to fully understand the GOT network interaction function before
using this function to control the authorization among pieces of equipment to
prevent simultaneous operations.
The exclusive authorization control of the GOT network interaction function
can be enabled or disabled for each screen.
(For all screens, the exclusive authorization control is disabled by default.)
Properly determine the screens for which the exclusive authorization control
is required, and set the control by screen.
A screen for which the exclusive authorization control is disabled can be
operated simultaneously from pieces of equipment.
Make sure to determine the operation period for each operator, fully grasp the
circumstances of the field site, and ensure safety to perform operations.
When disposing of this product, treat it as industrial waste.
When disposing of batteries, separate them from other wastes according to
the local regulations.
(Refer to the GOT2000 Series User’s Manual (Hardware) for details of the
battery directive in the EU member states.)
When transporting lithium batteries, make sure to treat them based on the
transport regulations.
(Refer to the GOT2000 Series User’s Manual (Hardware) for details of the
regulated models.)
Make sure to transport the GOT main unit and/or relevant unit(s) in the
manner they will not be exposed to the impact exceeding the impact
resistance described in the general specifications of this manual, as they are
precision devices.
Failure to do so may cause the unit to fail.
Check if the unit operates correctly after transportation.
When fumigants that contain halogen materials such as fluorine, chlorine,
bromine, and iodine are used for disinfecting and protecting wooden
packaging from insects, they cause malfunction when entering our products.
Please take necessary precautions to ensure that remaining materials from
fumigant do not enter our products, or treat packaging with methods other
than fumigation (heat method).
Additionally, disinfect and protect wood from insects before packing products.
Manual name Manual number (Model code)
GOT2000 Series User’s Manual (Hardware)
SH-081194ENG (1D7MJ5)
GOT2000 Series User’s Manual (Utility)
SH-081195ENG (1D7MJ6)
Description Quantity
GT27 1
Battery (GT11-50BAT) (Attached to the GOT) 1
Installation fitting
4,
8(Only GT2715)
GT27 General Description (This manual) 1
1
GOT2000 Series Supplementary Description
(Compliance with the ATEX Directive)
1(Only GT2712-STWD,
GT2710-VTWD)
GOT2000 시리즈 보충 설명 (KCs 지침 준수 )
1(Only GT2712-STWD,
GT2710-VTWD)
(6) External controllers including multimedia and video supported (excluding
GT2705)
(7) Various extended functions supported
2. Part Names and Settings
The following shows the part names for GT2715, GT2712, GT2710, GT2708 and
GT2705.
No. Name Description
1) Display screen Displays the utility and the user-created screen.
2) Touch Panel
For operating the touch switches in the utility and the user-
created screen
3)
USB interface
(Host/Front face)
For connecting a USB mouse, a USB keyboard, or a USB
barcode reader, and transferring or saving data (Connector
shape: TYPE-A)
(Only GT2715-XTBA/D, GT2712-STBA/D, GT2710-STBA/D,
GT2710-VTBA/D, GT2708-STBA/D, GT2708-VTBA/D,
GT2705-VTBD)
4)
USB interface (Device
/Front face)
For connecting a personal computer (Connector shape: Mini-B)
(Only GT2715-XTBA/D, GT2712-STBA/D, GT2710-STBA/D,
GT2710-VTBA/D, GT2708-STBA/D, GT2708-VTBA/D,
GT2705-VTBD)
5) POWER LED
Lit in blue : Power is properly supplied.
Lit in orange : Screen saving
Blinks in orange/blue : Backlight failure
Not lit : Power is not supplied
6) Human sensor Detects human movement.(Only GT2715, GT2712)
7) Unit installation fitting Mounting fixtures for fixing the GOT to the control panel
8) Reset switch Hardware reset switch
9) Installation switch Used for OS installations at the GOT startup
5)
6)
3)
4)
1)2)
19)
7)7) 7) 17)
18)
20)
24)
23)
22)
21)
8)
9)
7)
7)
7)
7)
7)
10)
11)12)
13)
14)
15)
16)
GT2715
23)
19) 17)18)7) 7)
5)
6)
3)
4)
8) 9)
10)
13)
14)
11)12)
15)
16)
20)
7) 7)
1)2)
26)
25)
22)
24) 21)
GT2712
27)
27)
27)
27)
23)
10)
11)12)
7) 7)
8) 9)
17)
18)19)
7) 7)
5)
3)
4)
20)
13)
14)
15)
16)
1)2)
26)
25)
22)
24) 21)
GT2710
23)
27)
27)
10)
11)12)13)
14)
15)
20)
8)
7) 7)
5)
3)
4)
7) 7)
17)
18)19)
1)2)
16)
25)
22)
24) 21)
9)
GT2708
23)
10)
11)12)13)
14)
15)
8)
9)
5)
3)
4)
25)
24)
22)
21)
20)
7) 7)
7) 7)
19)
1)2)
17)
GT2705
23)
*1:GT2705-V when used, for using multiple extension units, a barcode reader or an
RFID controller, the total current for the extension units, barcode reader or RFID
controller must be within the current that the GT2705-V can supply. refer to the
following GOT2000 Series Use’s Manual.
*2:Special installation fittings are sold separately. If you need the special installation
fittings, consult your local sales office.
3. Specifications
3.1 General Specifications
*1: The operating ambient temperature includes the temperature inside the
enclosure of the control panel to which the GOT is installed.
La température ambiante de fonctionnement inclut la température à l'intérieur
du boîtier du tableau de commande sur lequel le GOT est installé.
*2: When any of the following units and option is mounted on the GOT, the
maximum operating ambient temperature must be 5°C lower than the one
described above.
- Multimedia unit (GT27-MMR-Z)
- MELSECNET/H communication unit (GT15-J71LP23-25 or GT15-J71BR13)
- CC-Link communication unit (GT15-J61BT13)
- Protective cover for oil
10) SD card access LED
Lit : SD card mounted
Blinking : SD card accessed
No lit : SD card not mounted or SD card mounted
(removable)
11) SD card interface For installing a SD card
12) SD card cover
With a switching function for accepting and stopping the access
to the SD card
When the cover is opened : Access is prohibited
When the cover is closed : Access is allowed
13) Battery holder Houses the battery
14) Side interface For installing a communication unit
15)
USB interface
(Host/Back face)
For connecting a USB mouse, a USB keyboard, or a USB
barcode reader, and transferring or saving data (Connector
shape: TYPE-A)
16)
Hole for attaching a
cable clamp
Hole for attaching a cable clamp for preventing USB cable from
being pulled out (Recommended product: SKB-132PWD of SK
KOHKI CO., LTD. or corresponding product)
17)
Terminating resistor
setting switch
(Inside cover)
For switching on and off of the terminating resistor for the RS-
422/485 communication port (Default (Off))
18)
Auxiliary extension
interface
For installing an option unit
19) Extension interface
*1
For installing a communication unit or an option unit
20)
Vertical installation
arrow mark
For the vertical installation, install the GOT so that the arrow
points upward.
21) Power terminal Power input terminal, LG terminal, FG terminal
22) Ethernet interface
For communicating with a controller or connecting a personal
computer (Connector shape: RJ-45 (modular jack))
23)
Ethernet
communication status
LED
SD/RD LED ON: Data sent or received
SD/RD LED OFF: Data not sent or received
SPEED LED ON: Communicating at 100 Mbps
SPEED LED OFF: Communicating at 10 Mbps or disconnected
24) RS-232 interface
For communicating with a controller (Connector shape: D sub
9-pin (male))
25) RS-422/485 interface
For communicating with a controller (Connector shape: D sub
9-pin (female))
26)
USB interface
(Device/Back face)
For connecting personal computers (Connector shape: Mini-B)
(Only GT2712-STWA/D,GT2710-VTWA/D)
27)
Special installation
fitting mounting hole
*2
For fixing the GOT to the control panel to make the GOT
conform to the ATEX/KCs standard. (Only GT2712-STWA/D,
GT2710-VTWA/D)
Item Specifications
Operating ambient
temperature
*1
Température
ambiante de
fonctionnement
*1
0 to 55
*2
0 à 55
*2
Storage ambient
temperature
-20 to 60
Operating ambient
humidity
10 to 90% RH, non-condensing
Storage ambient
humidity
10 to 90% RH, non-condensing
Vibration resistance
Compliant
with JIS B
3502 and
IEC
61131-2
Frequency Acceleration
Half-
amplitude
Sweep
count
Under
intermittent
vibration
5 to
8.4Hz
-
3.5mm
10 times
each in X,
Y and Z
directions
8.4
to
150Hz
9.8m/s
2
-
Under
continuous
vibration
5 to
8.4Hz
-
1.75mm
-
8.4
to
150Hz
4.9m/s
2
-
Shock resistance
Compliant with JIS B 3502 and IEC 61131-2 147 m/s
2
(15G),
3 times each in X, Y and Z directions
Operating
atmosphere
No greasy fumes, corrosive gas, flammable gas
*6
, excessive
conductive dust, and direct sunlight (Same as storage atmosphere)
Operating altitude
*3
2000 m (6562 ft) max.
Installation location Inside control panel
Overvoltage
category
*4
II or less
Pollution degree
*5
2 or less
Cooling method Self-cooling
Grounding
Grounding with a ground resistance of 100 Ω or less by using a ground
cable that has a cross-sectional area of 2 mm
2
or more.
If impossible, connect the ground cable to the control panel.
No. Name Description
Lors du montage du module ou de l'option suivant, la température ambiante de
fonctionnement doit être réduite de 5°C par rapport aux valeurs maximales
dans les spécifications générales.
- Module multimédia (GT27-MMR-Z)
- Module de communication MELSECNET/H (GT15-J71LP23-25, GT15-
J71BR13)
- Module de communication CC-Link (GT15-J61BT13)
- Couvercle de protection contre l’huile
*3: Do not use or store the GOT under pressure higher than the atmospheric
pressure of altitude 0m (0ft.).
Failure to observe this instruction may cause a malfunction.
When an air purge is made inside the control panel by adding pressure, there
may be a clearance between the surface sheet and the screen making it difficult
to use the touch panel, or the sheet may come off.
*4: This indicates the section of the power supply to which the equipment is
assumed to be connected between the public electrical power distribution
network and the machinery within the premises.
Category II applies to equipment for which electrical power is supplied from
fixed facilities.
The surge voltage withstand level for up to the rated voltage of 300 V is 2500 V.
*5: This index indicates the degree to which conductive material is generated in the
environment where the equipment is used.
In pollution degree 2, only non-conductive pollution occurs but temporary
conductivity may be produced due to condensation.
*6: Some models have ANSI/ISA12.12.01 approval for use in Class I, Division 2
(ANSI/ISA 12.12.01, C22.2 No.213-M1987) hazardous locations.
For the details, please contact your local sales office.
3.2 Power Supply Specifications
The following indicates the power supply specifications for GT27.
3.2.1 For GOTs powered from the 100 to 240VAC
power supply
3.2.2 For GOTs powered from the 24VDC power
supply
Point
Refer to the GOT2000 Series User’s Manual (Hardware) for details on the performance
specifications of each GOT.
Note
Operation at momentary failure
• If an instantaneous power failure occurs in the power supply and continues for more
than the permissible period, the GOT will be reset.
• Make sure to power on the unit more than 5 seconds after power-off.
Item
Specifications
GT2715-XTBA
GT2712-STBA
GT2712-
STWA
GT2710-STBA
GT2710-VTBA
GT2710-
VTWA
GT2708-STBA
GT2708-VTBA
Power supply voltage AC100 to 240VAC (+10%, -15%)
Power frequency 50/60Hz 5%
Max. apparent power 140VA 100VA
Power
consum
ption
maximum load 51W or less 44W or less 41W or less
Stand alone 25W 19W 17W 15W
Stand alone with
backlight off
10W
Inrush current
40A or less (3ms,
operating ambient
temperature 25,
maximum load)
60A or less (2ms, operating ambient
temperature 25, maximum load)
Allowable momentary power
failure time
20 ms or less (100VAC or more)
Noise immunity
1,500Vp-p noise voltage, 1 s noise width (when
measuring with a noise simulator under 25 to 60Hz
noise frequency)
Dielectric withstand voltage 1500VAC for 1 minute across power terminals and earth
Insulation resistance
10M or more across power terminals and earth by a
500V DC insulation resistance tester
Applicable wire size 0.75[mm
2
] to 2[mm
2
]
Applicable solderless terminal
Solderless terminal for M3 screw RAV1.25-3, V2-S3.3,
V2-N3A, FV2-N3A
Applicable tightening torque
(Terminal block terminal screw)
0.5[N•m] to 0.8[N•m]
Item
Specifications
GT2715-
XTBD
GT2712-
STBD,
GT2712-
STWD
GT2710-
STBD,
GT2710-
VTBD,
GT2710-
VTWD
GT2708-
STBD,
GT2708-
VTBD
GT2705-
VTBD
Power supply voltage DC24V (+25%, -20%)
Power
consu
mption
maximum load
48W or
less
45W or
less
42W or
less
39W or
less
30W or
less
Stand alone 23W 18W 15W 13W 7W
Stand alone with
backlight off
8W 8W 8W 8W 5W
Inrush current
5A or less (20ms, operating ambient temperature
25, maximum load)
69A or less
(1ms, operating
ambient
temperature 25,
maximum load)
Allowable momentary
power failure time
10 ms or less
Noise immunity
500Vp-p noise voltage, 1 s noise width (when measuring with
a noise simulator under 25 to 60Hz noise frequency)
Dielectric withstand
voltage
350VAC for 1 minute across power terminals and earth
Insulation resistance
10M or more across power terminals and earth by a 500V DC
insulation resistance tester
Applicable wire size 0.75[mm
2
] to 2[mm
2
]
Applicable solderless
terminal
Solderless terminal for M3 screw RAV1.25-3, V2-S3.3, V2-
N3A, FV2-N3A
Applicable tightening
torque (Terminal block
terminal screw)
0.5[N•m] to 0.8[N•m]