GT25 General Description
Thank you for choosing Mitsubishi Electric Graphic Operation
Terminal (GOT).
© 2014 MITSUBISHI ELECTRIC CORPORATION
GT2512-STBA
GT2510-VTBD
GT2508-VTBD
GT2512-STBD
GT2510-VTWD
GT2508-VTWD
GT2510-VTBA
GT2508-VTBA
GT2505-VTBD
GT2510-VTWA
GT2508-VTWA
Prior to use, please read both this manual and the
detailed manual thoroughly to fully understand the
product.
MODEL GT25-U-GD-E
Model
code
1D7MN4
IB(NA)-0800537ENG-L(2102)MEE
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
SAFETY PRECAUTIONS
(Always read these precautions before using this equipment.)
Before using this product, please read this manual and the relevant
manuals introduced in this manual carefully and pay full attention to
safety to handle the product correctly.
The precautions given in this manual are concerned with this
product.
In this manual, the safety precautions are ranked as "WARNING"
and "CAUTION".
Note that the CAUTION level may lead to a serious accident
according to the circumstances.
Always follow the instructions of both levels because they are
important to personal safety.
Please save this manual to make it accessible when required and
always forward it to the end user.
[DESIGN PRECAUTIONS]
Indicates that incorrect handling may cause
hazardous conditions, resulting in death or
severe injury.
Indicates that incorrect handling may cause
hazardous conditions, resulting in medium or
slight personal injury or physical damage.
Some failures of the GOT, communication unit or cable may keep the outputs on
or off.
Some failures of a touch panel may cause malfunction of the input objects such
as a touch switch.
An external monitoring circuit should be provided to check for output signals
which may lead to a serious accident.
Not doing so can cause an accident due to false output or malfunction.
Do not use the GOT as the warning device that may cause a serious accident.
An independent and redundant hardware or mechanical interlock is required to
configure the device that displays and outputs serious warning.
Failure to observe this instruction may result in an accident due to incorrect
output or malfunction.
When the GOT backlight has a failure, the POWER LED blinks (orange/blue),
the display section dims, and inputs by a touch switch are disabled.
Failure to observe this instruction may result in an accident due to incorrect
output or malfunction.
Even if the display section dims, inputs by a touch switch may still be available.
This may cause an unintended operation of the touch switch.
For example, if an operator assumes that the display section has dimmed
because of the screen save function and touches the display section to cancel
the screen save, a touch switch may be activated.
The GOT backlight failure can be checked with a system signal of the GOT.
The display section of the GOT is an analog-resistive type touch panel.
Do not touch two points or more simultaneously on the display section.
Doing so may cause a touch switch near the touched points to operate
unexpectedly, or may cause an accident due to an incorrect output or
malfunction.
When programs or parameters of the controller (such as a PLC) that is monitored
by the GOT are changed, be sure to reset the GOT, or turn on the unit again after
shutting off the power as soon as possible.
Not doing so can cause an accident due to false output or malfunction.
If a communication fault (including cable disconnection) occurs during monitoring
on the GOT, communication between the GOT and PLC CPU is suspended and
the GOT becomes inoperative.
For bus connection : The PLC CPU becomes faulty and the GOT becomes
inoperative.
For other than bus connection : The GOT becomes inoperative.
A system where the GOT is used should be configured to perform any significant
operation to the system by using the switches of a device other than the GOT on
the assumption that a GOT communication fault will occur.
Not doing so can cause an accident due to false output or malfunction.
[MOUNTING PRECAUTIONS]
To maintain the security (confidentiality, integrity, and availability) of the GOT
and the system against unauthorized access, DoS
*1
attacks, computer viruses,
and other cyberattacks from unreliable networks and devices via network, take
appropriate measures such as firewalls, virtual private networks (VPNs), and
antivirus solutions.
Mitsubishi Electric shall have no responsibility or liability for any problems
involving GOT trouble and system trouble by unauthorized access, DoS
attacks, computer viruses, and other cyberattacks.
*1 DoS: A denial-of-service (DoS) attack disrupts services by overloading
systems or exploiting vulnerabilities, resulting in a denial-of-service (DoS) state.
Products with the Cl.I, DIV.2 mark on the rating plate are suitable for use in Class
I, Division 2, Groups A, B, C and D hazardous locations, or nonhazardous
locations only.
This mark indicates that the product is certified for use in the Class I, Division2
environment where flammable gases, vapors, or liquids are not likely to exist
under normal conditions.
When using the products in the Class I, Division 2 environment, observe the
following to reduce the risk of explosion.
• This device is open-type and is to be installed in an enclosure suitable for
the environment and require a tool or key to open.
• Warning - Explosion Hazard - Substitution of any component may impair
suitability for Class I, Division 2.
• Warning - Explosion Hazard - Do not connect or disconnect equipment or
disconnect external connection terminals unless power has been removed or the
area is known to be non-hazardous.
• The side interface and extension interface of this equipment cannot be used
in Class I, Division 2 environments.
Les produits marqués Cl.I, DIV.2 sur la plaque signalétique peuvent être utilisés
en Class I, Division 2, local dangereux de groupe A, B, C et D, ou uniquement en
local non dangereux.
Ce logo indique que le produit est homologué pour utilisation en environnement
de Class I, Division 2 où, dans des circonstances anormales, il peut y avoir
présence de gaz, vapeurs ou liquides inflammables.
Si le produit est utilisé en environnement de Class I, Division 2, observer les
précautions suivantes pour réduire le risque d'explosion.
• Cet appareil est de type ouvert et il doit être installé dans une enceinte
appropriée à l'environnement et ne pouvant être ouverte qu'au moyen
d'une clé ou d'un outil.
• Avertissement - Danger d'explosion - Toute substitution de composant
peut compromettre l'aptitude à l'utilisation en Class I, Division 2.
• Avertissement - Danger d'explosion - Ne pas connecter ou déconnecter
l'équipement ni déconnecter les bornes de connexion externes quand le
circuit est sous tension, ni avant de d'être assuré de l'absence d'atmosphère
inflammable.
• L’interface latérale et l’interface d’extension de cet équipement ne
peuvent être utilisées dans les environnements de Classe I, Division 2.
Do not bundle the control and communication cables with main-circuit, power or
other wiring.
Run the above cables separately from such wiring and keep them a minimum of
100mm apart.
Not doing so noise can cause a malfunction.
Do not press the GOT display section with a pointed material as a pen or driver.
Doing so can result in a damage or failure of the display section.
When the GOT connects to an Ethernet network, the IP address setting is
restricted according to the system configuration.
When a GOT2000 series model and a GOT1000 series model are on an
Ethernet network, do not set the IP address 192.168.0.18 for the GOTs and the
controllers on this network.
Doing so can cause IP address duplication at the GOT startup, adversely
affecting the communication of the device with the IP address 192.168.0.18.
The operation at the IP address duplication depends on the devices and the
system.
Turn on the controllers and the network devices to be ready for communication
before they communicate with the GOT.
Failure to do so can cause a communication error on the GOT.
When the GOT is subject to shock or vibration, or some colors appear on the
screen of the GOT, the screen of the GOT might flicker.
Be sure to shut off all phases of the external power supply used by the system
before mounting or removing the GOT main unit to/from the panel.
Not doing so can cause the unit to fail or malfunction.
Be sure to shut off all phases of the external power supply used by the system
before mounting or removing the communication unit or the option unit onto/from
the GOT.
Use the GOT in the environment that satisfies the general specifications
described in this manual.
Not doing so can cause an electric shock, fire, malfunction or product damage or
deterioration.
When mounting the GOT to the control panel, tighten the mounting screws in the
specified torque range with a Phillips-head screwdriver No. 2.
• GT2512
, GT2510, GT2508: Specified torque range (0.36 N•m to 0.48 N•m)
• GT2505: Specified torque range (0.30 N•m to 0.50 N•m)
Undertightening can cause the GOT to drop, short circuit or malfunction.
Overtightening can cause a drop, short circuit or malfunction due to the damage
of the screws or unit.
When mounting a unit on the GOT, tighten the mounting screws in the following
specified torque range.
When loading the communication unit or option unit other than wireless LAN unit
to the GOT, fit it to the connection interface of the GOT and tighten the mounting
screws in the specified torque range (0.36 N•m to 0.48 N•m) with a Phillips-head
screwdriver No.2.
When loading the wireless LAN unit to the GOT, fit it to the side interface of GOT
and tighten the mounting screws in the specified torque range (0.10 N•m to 0.14
N•m) with a Phillips-head screwdriver No.1.
When the GOT is installed vertically, its side interface is positioned on the bottom.
To prevent the falling of the wireless LAN communication unit from the side
interface, install or remove the unit while holding it with hands.
Under tightening can cause the GOT to drop, failure or malfunction.
Overtightening can cause a drop, failure or malfunction due to the damage of the
screws or unit.
[WIRING PRECAUTIONS]
[TEST OPERATION PRECAUTIONS]
[STARTUP/MAINTENANCE PRECAUTIONS]
When closing the USB environmental protection cover, note the following points
to ensure the IP rating.
[GT25 (except GT2505-V)]
Push the [PUSH] mark on the latch firmly to fix the cover to the GOT.
[GT2505-V]
Push the USB mark on the latch firmly to fix the cover to the GOT.
Remove the protective film of the GOT.
When the user continues using the GOT with the protective film, the film may not
be removed.
Do not operate or store the GOT in the environment exposed to direct sunlight,
high temperature, dust, humidity, or vibrations.
When using the GOT in the environment of oil or chemicals, use the protective
cover for oil.
Failure to do so may cause failure or malfunction due to the oil or chemical
entering into the GOT.
Be sure to shut off all phases of the external power supply used by the system
before wiring.
Failure to do so may result in an electric shock, product damage or malfunctions.
Make sure to ground the FG terminal and LG terminal of the GOT power supply
section solely for the GOT (ground resistance: 100 Ω or less, ground cable
diameter: 1.6 mm or more).
Not doing so may cause an electric shock or malfunction.
When tightening the terminal screws, use a Phillips-head screwdriver No.2.
Terminal screws which are not to be used must be tightened always at torque 0.5
N•m to 0.8 N•m.
Otherwise there will be a danger of short circuit against the solderless terminals.
Use applicable solderless terminals and tighten them with the specified torque.
If any solderless spade terminal is used, it may be disconnected
when the terminal screw comes loose, resulting in failure.
Correctly wire the GOT power supply section after confirming the rated voltage
and terminal arrangement of the product.
Not doing so can cause a fire or failure.
Tighten the terminal screws of the GOT power supply section in the specified
torque range (0.5 N•m to 0.8 N•m).
Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of the
screws or unit.
Exercise care to avoid foreign matter such as chips and wire offcuts entering the
GOT.
Not doing so can cause a fire, failure or malfunction.
The module has an ingress prevention label on its top to prevent foreign matter,
such as wire offcuts, from entering the module during wiring.
Do not peel this label during wiring.
Before starting system operation, be sure to peel this label because of heat
dissipation.
Plug the communication cable into the GOT interface or the connector of the
connected unit, and tighten the mounting screws and the terminal screws in the
specified torque range.
Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of the
screws or unit.
Plug the QnA/ACPU/Motion controller (A series) bus connection cable by
inserting it into the connector of the connected unit until it "clicks".
After plugging, check that it has been inserted snugly.
Not doing so can cause a malfunction due to a contact fault.
Before testing the operation of a user-created monitor screen (such as turning on
or off a bit device, changing the current value of a word device, changing the set
value or current value of a timer or counter, and changing the current value of a
buffer memory), thoroughly read the manual to fully understand the operating
procedures.
During the test operation, never change the data of the devices which are used
to perform significant operation for the system.
False output or malfunction can cause an accident.
When power is on, do not touch the terminals.
Doing so can cause an electric shock.
Correctly connect the battery connector.
Do not charge, disassemble, heat, short-circuit, solder, or throw the battery into
the fire.
Doing so will cause the battery to produce heat, explode, or ignite, resulting in
injury and fire.
Before starting cleaning or terminal screw retightening, always switch off the
power externally in all phases.
Not switching the power off in all phases can cause a unit failure or malfunction.
Undertightening can cause a drop, short circuit or malfunction.
Overtightening can cause a drop, short circuit or malfunction due to the damage
of the screws or unit.
Do not disassemble or modify the unit.
Doing so can cause a failure, malfunction, injury or fire.
Do not touch the conductive and electronic parts of the unit directly.
Doing so can cause a unit malfunction or failure.
The cables connected to the unit must be run in ducts or clamped.
Not doing so can cause the unit or cable to be damaged due to the dangling,
motion or accidental pulling of the cables or can cause a malfunction due to a
cable connection fault.
When unplugging the cable connected to the unit, do not hold and pull from the
cable portion.
Doing so can cause the unit or cable to be damaged or can cause a malfunction
due to a cable connection fault.
Do not drop the module or subject it to strong shock.
A module damage may result.
[TOUCH PANEL PRECAUTIONS]
[
PRECAUTIONS WHEN THE DATA STORAGE IS IN USE
]
[PRECAUTIONS FOR USE]
[PRECAUTIONS FOR REMOTE CONTROL]
[PRECAUTIONS FOR EXCLUSIVE AUTHORIZATION CONTROL]
Do not drop or give an impact to the battery mounted to the unit.
Doing so may damage the battery, causing the battery fluid to leak inside the
battery.
If the battery is dropped or given an impact, dispose of it without using.
Before touching the unit, always touch grounded metals, etc. to discharge static
electricity from human body, etc.
Not doing so can cause the unit to fail or malfunction.
Use the battery manufactured by Mitsubishi Electric Corporation.
Use of other batteries may cause a risk of fire or explosion.
Dispose of used battery promptly.
Keep away from children.
Do not disassemble and do not dispose of in fire.
Be sure to shut off all phases of the external power supply before replacing the
battery or using the dip switch of the terminating resistor.
Not doing so can cause the unit to fail or malfunction by static electricity.
For the analog-resistive film type touch panels, normally the adjustment is not
required.
However, the difference between a touched position and the object position may
occur as the period of use elapses.
When any difference between a touched position and the object position occurs,
execute the touch panel calibration.
When any difference between a touched position and the object position occurs,
other object may be activated.
This may cause an unexpected operation due to incorrect output or malfunction.
If the SD card is removed from drive A of the GOT while being accessed by the
GOT, the GOT may stop processing data for about 20 seconds.
The GOT cannot be operated during this period.
The functions that run in the background including a screen updating, alarm,
logging, scripts, and others are also interrupted.
Since this interruption makes an impact to the system operation, it might cause
failure.
Check that the SD card access LED is off before removing the SD card.
If the data storage is removed from the GOT while being accessed by the GOT,
the data storage and files may be damaged.
Before removing the data storage from the GOT, check the SD card access LED,
system signal, or others to make sure that the data storage is not accessed.
Turning off the GOT while it accesses the SD card results in damage to the SD
card and files.
Make sure to turn off the SD card access switch before removing the SD card
from the GOT.
Not doing so may damage the SD card or files. (GT2505 only)
After inserting an SD card into the GOT, make sure to close the SD card cover.
Not doing so causes the data not to be read or written.
When removing the SD card from the GOT, make sure to support the SD card by
hand as it may pop out.
Not doing so may cause the SD card to drop from the GOT, resulting in a failure
or break.
When inserting a USB device into a USB interface of the GOT, make sure to
insert the device into the interface firmly.
Not doing so can cause a malfunction due to a contact failure.
Before removing the data storage from the GOT, follow the procedure for
removal on the utility screen of the GOT.
After the successful completion dialog is displayed, remove the data storage by
hand carefully.
Not doing so may cause the data storage to drop from the GOT, resulting in a
failure or break.
Do not touch the outer edge of the actual display area repeatedly.
Doing so may result in a failure.
Do not turn off the GOT while data is being written to the storage memory (ROM)
or SD card.
Doing so may corrupt the data, rendering the GOT inoperative.
Remote control is available through a network by using GOT functions, including
the SoftGOT-GOT link function, the remote personal computer operation
function, the VNC server function, and the GOT Mobile function.
If these functions are used to perform remote control of control equipment, the
field operator may not notice the remote control, possibly leading to an accident.
In addition, a communication delay or interruption may occur depending on the
network environment, and remote control of control equipment cannot be
performed normally in some cases.
Before using the above functions to perform remote control, fully grasp the
circumstances of the field site and ensure safety.
Make sure to fully understand the GOT network interaction function before using
this function to control the authorization among pieces of equipment to prevent
simultaneous operations.
The exclusive authorization control of the GOT network interaction function can
be enabled or disabled for each screen.
(For all screens, the exclusive authorization control is disabled by default.)
Properly determine the screens for which the exclusive authorization control is
required, and set the control by screen.
A screen for which the exclusive authorization control is disabled can be
operated simultaneously from pieces of equipment.
Make sure to determine the operation period for each operator, fully grasp the
circumstances of the field site, and ensure safety to perform operations.
[DISPOSAL PRECAUTIONS]
[TRANSPORTATION PRECAUTIONS]
Manuals
The following shows manuals relevant to this product.
For detailed manuals and relevant manuals, refer to the e-Manual or PDF
manuals stored in the DVD-ROM for the screen design software used.
The latest manuals are also available from MITSUBISHI ELECTRIC FA Global
Website (www.MitsubishiElectric.com/fa).
Compliance with the new China RoHS directive
GOT 相关的基于 “ 电器电子产品有害物质限制使用管理办法 ” 要求的表示方法
含有有害 6 物质的名称、含有量、含有部件
本产品中所含有的有害 6 物质的名称、含有量、含有部件如下表所示。
产品中有害物质的名称及含量
本表格依据 SJ/T11364 的规定编制。
○ : 表示该有害物质在该部件所有均质材料中的含量均在 GB/T26572 规定的限量要
求以下。
× : 表示该有害物质至少在该部件的某一均质材料中的含量超出 GB/T26572 规定的
限量要求。
Referenced Standard: GB/T15969.2
(Requirement of Chinese standardized law)
Before using the GOT
Connect the connector of the GOT to the connector of the battery.
For GT2505, the battery is connected to the GOT before shipment.
Refer to the GOT2000 Series User’s Manual (Hardware) for the connection
instructions.
For details on the GOT specifications, installing instructions, wiring, maintenance
and inspection, or checking procedure for the version and the compatible standard,
refer to the GOT2000 Series User’s Manual (Hardware).
Packing List
The GOT product package includes the following:
When disposing of this product, treat it as industrial waste.
When disposing of batteries, separate them from other wastes according to the
local regulations.
(Refer to the GOT2000 Series User’s Manual (Hardware) for details of the
battery directive in the EU member states.)
When transporting lithium batteries, make sure to treat them based on the
transport regulations.
(Refer to the GOT2000 Series User’s Manual (Hardware) for details of the
regulated models.)
Make sure to transport the GOT main unit and/or relevant unit(s) in the manner
they will not be exposed to the impact exceeding the impact resistance described
in the general specifications of this manual, as they are precision devices.
Failure to do so may cause the unit to fail.
Check if the unit operates correctly after transportation.
When fumigants that contain halogen materials such as fluorine, chlorine,
bromine, and iodine are used for disinfecting and protecting wooden packaging
from insects, they cause malfunction when entering our products.
Please take necessary precautions to ensure that remaining materials from
fumigant do not enter our products, or treat packaging with methods other than
fumigation (heat method).
Additionally, disinfect and protect wood from insects before packing products.
Manual name Manual number (Model code)
GOT2000 Series User’s Manual (Hardware)
SH-081194ENG (1D7MJ5)
GOT2000 Series User’s Manual (Utility)
SH-081195ENG (1D7MJ6)
Note: This symbol mark is for China only.
部件名称
有害物质
铅
(Pb)
汞
(Hg)
镉
(Cd)
六价铬
(Cr(VI))
多溴联苯
(PBB)
多溴二苯醚
(PBDE)
电路板组件 × ○ ○ ○ ○ ○
树脂壳体、电缆、膜材 ○ ○ ○ ○ ○ ○
钣金部件、螺丝等金属部件 × ○ ○ ○ ○ ○
Description Quantity
GT25 1
Battery (GT11-50BAT) (Attached to the GOT) 1
Installation fitting 4
Gasket (for mounting the GOT on the control panel) 1 (only GT2505-VTBD)
GT25 General Description (This manual) 1
1
GOT2000 Series Supplementary Description
(Compliance with the ATEX Directive)
1 (only GT2510-VTWD,
GT2508-VTWD)
GOT2000 시리즈 보충 설명 (KCs 지침 준수 )
1 (only GT2510-VTWD,
GT2508-VTWD)
1. FEATURES
(1) Abundant standard equipment
• Variety of connection with FA devices
• SD card interface compatible with the SDHC card having a large capacity
and allowing high-speed communication
• Connection with various peripheral devices with the USB host
(2) Improved usability
• Abundant troubleshooting
• Easy and clear screen creation
• PC-like operation screen
• Support for the vertical installation
(3) Enhanced compatibility with Mitsubishi Electric FA devices
(4) Easy replacement]
(5) LED backlight
(6) Various extended functions supported
2. Part Names and Settings
The following shows the part names for GT2512, GT2510, GT2508 and GT2505.
No. Name Description
1) Display screen Displays the utility and the user-created screen
2) Touch panel
For operating the touch switches in the utility and the user-
created screen
3)
USB interface
(Host/Front face)
For connecting a USB mouse, a USB keyboard, or a USB
barcode reader, and transferring or saving data
(Connector shape: TYPE-A) (only GT2512-STBA/D, GT2510-
VTBA/D
and GT2508-VTBA/D)
4)
USB interface
(Device /Front face)
For connecting a personal computer
(Connector shape: Mini-B) (only GT2512-STBA/D, GT2510-
VTBA/D, GT2508-VTBA/D
and GT2505)
5) POWER LED
Lit in blue : Power is properly supplied
Lit in orange : Screen saving
Blinks in orange/blue : Backlight failure
Not lit : Power is not supplied
GT2512
1)2)
5)
23)
17)
7)
16)
8)
9)
10)
11)
12)
13)
14)
22)20) 19)
6) 6)
6) 6)
3)4)
15)
18)
21)
28)
GT2510
12)
13)
14)
23)22)20) 19)
6)
6)
17)
7)
16)
8)
6) 6)1)2)
18)
3)4)
24)
15)
21)
25)
25)
9)
10)
11)
28)
GT2508
9)
10)11)12)
16)
13)
14)
23)22)20) 19)
6) 6)17)
7)
8)
6) 6)
1)2)
5)
3)4)
15)
24)
18)
21)
28)
GT2505
10)
21)
4)
19)20)
6)
9)
7)
6) 6)
1)2)
5)
14)6)
26)
22)
23)
12)16)
18)
27) 28)
*1: Special installation fittings are sold separately. If you need the special
installation fittings, consult your local sales office.
*2: GT2505 does not have the LG terminal.
3. Specifications
3.1 General Specifications
6) Unit installation fitting Mounting fixtures for fixing the GOT to the control panel
7) Reset switch Hardware reset switch
8) Installation switch Used for OS installations at the GOT startup
9) SD card access LED
Lit: SD card mounted
Blinking: SC card accessed
No lit: SD card not mounted or SD card mounted (removable)
10) SD card interface For installing a SD card
11) SD card cover
With a switching function for accepting and stopping the
access to the SD card (only GT2512, GT2510
and GT2508)
When the cover is opened : Access is prohibited
When the cover is closed : Access is allowed
12) Battery holder Houses the battery
13) Side interface For installing a communication unit
14)
USB interface
(Host/Back face)
For connecting a USB mouse, a USB keyboard, or a USB
barcode reader, and transferring or saving data
(Connector shape: TYPE-A)
15)
Hole for attaching a
cable clamp
Hole for attaching a cable clamp for preventing USB cable
from being pulled out
(Recommended product: SKB-132PWD of SK KOHKI CO.,
LTD. or corresponding product)
16)
Terminating resistor
setting switch
(Inside cover)
・ For GT2512, GT2510, GT2508
For switching on and off of the terminating resistor for the
RS-422/485 communication port (Default (Off))
・ For GT2505
For switching the terminating resistor for the RS-422/485
communication port to 330 Ω, 110 Ω, or OPEN
(Default: 330 Ω)
17) Extension interface For installing a communication unit or an option unit
18)
Vertical installation
arrow mark
For the vertical installation, install the GOT so that the arrow
points upward.
19) Power terminal Power input terminal, LG
*2
terminal, FG terminal
20) Ethernet interface
For communicating with a controller or connecting a personal
computer (Connector shape: RJ-45 (modular jack))
21)
Ethernet
communication
status LED
SD/RD LED ON : Data sent or received
SD/RD LED OFF: Data not sent or received
SPEED LED ON : Communicating at 100 Mbps
SPEED LED OFF: Communicating at 10 Mbps or
disconnected
22) RS-232 interface
For communicating with a controller (Connector shape: D sub
9-pin (male))
23)
RS-422/485
interface
For communicating with a controller (Connector shape: D sub
9-pin (female))
24)
USB interface
(Device/Back face)
For connecting personal computers (Connector shape: Mini-
B)
(only GT2510-VTWA/D, GT2508-VTWA/D)
25)
Special installation
fitting mounting
hole
*1
For fixing the GOT to the control panel to make the GOT
conform to the ATEX/KCs standard.
(only GT2510-VTWA/D)
26)
SD card access
switch
For enabling or disabling the access to the SD card when
inserting/removing the SD card to/from the GOT (only
GT2505)
ON: SD card is being accessed. (The SD card cannot be
removed.)
OFF: SD card is not accessed. (The SD card can be
removed.)
27)
Preventive hole from
removing for the
USB cable
Hole fixed with banding band or others as a prevention from
removing for the USB cable
28) Rating plate -
Item Specifications
Operating ambient
temperature
*1
Température
ambiante de
fonctionnement
*1
0 to 55°C
*2*7
0 à 55°C
*2*7
Storage ambient
temperature
-20 to 60°C
Operating ambient
humidity
10 to 90% RH, non-condensing
*8
Storage ambient
humidity
10 to 90% RH, non-condensing
*8
Vibration resistance
Compliant
with JIS B
3502 and
IEC
61131-2
Frequency
Acceleration
Half-
amplitude
Sweep
count
Under
intermittent
vibration
5 to
8.4 Hz
-
3.5 mm
10 times
each in X,
Y and Z
directions
8.4
to
150 Hz
9.8m/s
2
-
Under
continuous
vibration
5 to
8.4 Hz
-
1.75 mm
-
8.4
to
150 Hz
4.9m/s
2
-
Shock resistance
Compliant with JIS B 3502 and IEC 61131-2 147 m/s
2
(15G),
3 times each in X, Y and Z directions
Operating
atmosphere
*6
No greasy fumes, corrosive gas, flammable gas, excessive
conductive dust, and direct sunlight (Same as storage atmosphere)
Operating altitude
*3
2000 m (6562 ft) max.
Installation location Inside control panel
No. Name Description
*1: The operating ambient temperature includes the temperature inside the
enclosure of the control panel to which the GOT is installed.
La température ambiante de fonctionnement inclut la température à l'intérieur
du boîtier du tableau de commande sur lequel le GOT est installé.
*2: When any of the following units and option is mounted on the GOT, the
maximum operating ambient temperature must be 5°C lower than the one
described above.
- MELSECNET/H communication unit (GT15-J71LP23-25 or GT15-J71BR13)
- CC-Link communication unit (GT15-J61BT13)
- Protective cover for oil
Lors du montage du module ou de l'option suivant, la température ambiante de
fonctionnement doit être réduite de 5°C par rapport aux valeurs maximales
dans les spécifications générales.
- Module de communication MELSECNET/H (GT15-J71LP23-25, GT15-
J71BR13)
- Module de communication CC-Link (GT15-J61BT13)
- Couvercle de protection contre l’huile
*3: Do not use or store the GOT under pressure higher than the atmospheric
pressure of altitude 0m (0ft.).Failure to observe this instruction may cause a
malfunction.When an air purge is made inside the control panel by adding
pressure, there may be a clearance between the surface sheet and the screen
making it difficult to use the touch panel, or the sheet may come off.
*4: This indicates the section of the power supply to which the equipment is
assumed to be connected between the public electrical power distribution
network and the machinery within the premises. Category II applies to
equipment for which electrical power is supplied from fixed facilities.
The surge voltage withstand level for up to the rated voltage of 300 V is 2500 V.
*5: This index indicates the degree to which conductive material is generated in the
environment where the equipment is used.
In pollution degree 2, only non-conductive pollution occurs but temporary
conductivity may be produced due to condensation.
*6: Some models have ANSI/ISA12.12.01 approval for use in Class I, Division 2
(ANSI/ISA 12.12.01, C22.2 No.213-M1987) hazardous locations.
For the details, please contact your local sales office.
*7: When GT2505 is installed vertically, the operating ambient temperature must
be between 0°C and 50°C.
Pour le GT2505 orienté à la verticale, la température ambiante de
fonctionnement doit être 0 à 50°C.
*8: Only for GT2505-V, the absolute humidity must not exceed 90% at 40°C if the
ambient temperature exceeds 40°C.
*9: GT2512, GT2510, GT2508 is for use on a flat surface of a Type 1 enclosure.
*10:GT2505 is for use on a flat surface of a Type 1 or Type 4X (indoor use only)
enclosure.
3.2 Power Supply Specifications
The following indicates the power supply specifications for GT25.
3.2.1 For GOTs powered from the 100 to 240VAC
power supply
Item Specifications
Overvoltage
category
*4
II or less
Pollution degree
*5
2 or less
Cooling method Self-cooling
Grounding
Grounding with a ground resistance of 100 Ω or less by using a ground
cable that has a cross-sectional area of 2 mm
2
or more.
If impossible, connect the ground cable to the control panel.
Type rating
UL Type 1
*9
UL Type 1 or UL Type 4X (indoor use only)
*10
Point
Refer to the GOT2000 Series User’s Manual (Hardware) for details on the performance
specifications of each GOT.
Note
Operation at momentary failure
• If an instantaneous power failure occurs in the power supply and continues for more
than the permissible period, the GOT will be reset.
• Make sure to power on the unit more than 5 seconds after power-off.
Item
Specifications
GT2512-STBA
GT2510-VTBA,
GT2510-VTWA
GT2508-VTBA,
GT2508-VTWA
Power supply voltage Power supply voltage AC100 to 240VAC (+10%, -15%)
Power frequency 50/60Hz 5%
Max. apparent power 80VA 80VA 70VA
Power
consum
ption
maximum load 35W or less 34W or less 31W or less
Stand alone 14W 12W 11W
Stand alone with
backlight off
7W 7W 7W
Inrush current
60A or less (2ms, operating ambient temperature 25,
maximum load)
Allowable momentary power
failure time
20 ms or less (100VAC or more)
Noise immunity
1,500Vp-p noise voltage, 1 s noise width (when
measuring with a noise simulator under 25 to 60Hz
noise frequency)
Dielectric withstand voltage 1500VAC for 1 minute across power terminals and earth
Insulation resistance
10M or more across power terminals and earth by a
500V DC insulation resistance tester
Applicable wire size 0.75[mm
2
] to 2[mm
2
]
Applicable solderless terminal
Solderless terminal for M3 screw RAV1.25-3, V2-S3.3,
V2-N3A, FV2-N3A
Applicable tightening torque
(Terminal block terminal screw)