Boneco 7135 Manuel utilisateur

Catégorie
Humidificateurs
Taper
Manuel utilisateur
PLEASE READ AND SAVE
ALL INSTRUCTIONS!
LISEZ ET CONSERVEZ
TOUTES LES INSTRUCTIONS!
¡POR FAVOR LEA Y
GUARDE TODAS
LAS INSTRUCCIONES!
7135
3
Instructions for use (5 – 16)
en
Instructions d’utilisation (17 – 28)
a
fr
Instrucciones para el uso (29 – 42)
a
es
4
5
en
Instructions for use
6
en
Important safety instructions
Prior to using the appliance, read through the
in structions for complete use and retain in a safe place
for later reference.
WARNING – Only use the Ultrasonic indoors and within
the specified technical data. Improper use can be
hazardous for the health and lead to critical injury.
Connect the unit only to alternating current (AC) with
voltage according to the rating label.
Children cannot recognize the hazards associated
with the usage of electrical appliances. For this reason,
always supervise children when they are near the
humidifier (image 1).
Never use the appliance if there is any damage to the
appliance or cable (2), after malfunction, after the
appliance has been dropped (3) or damaged in any
other way.
Repairs of electrical appliances are only to be made by
qualified service engineers (4). Improper repair work
can cause considerable danger to the user.
Place the humidifier on a dry, level surface (5).
Do not place the appliance directly on the floor or
next to a heating vent (6).
If the mist comes in contact with the floor prior to
evaporating, the floor surface can become damaged.
We do not accept any liability for damages in the case
of incorrect placement of the unit.
The unit should be placed in an elevated position (7),
e.g. on a table, chest of drawers, etc.
Place appliance where it is not easily knocked over (8).
Always unplug when not in use.
Only operate the humidifier when it is completely
assembled.
ALWAYS unplug before removing/filling/emptying the
water tank, before cleaning/maintaining, assembling/
dismantling of individual parts and before moving the
appliance.
Do not touch the water in the base during operation
because of high frequency vibrations in the water.
Do not run power cords under carpets, and do not
cover with throw rugs. Arrange cord so that it will not
be tripped over.
Never pull the plug from the outlet by the cable or with
wet hands.
Do not use the appliance where combustible gases or
vapors are present.
Do not expose the appliance to rain, or use near water,
in a bathroom, laundry area or other damp location.
This unit must be used in its upright position.
Do not allow foreign objects to enter ventilation or
ex haust opening as this may cause electric shock or
damage to the appliance. Do not block air outlets or
intakes.
Do not pour water into the mist outlet of the appliance.
This appliance has a polarized plug (one blade is wider
than the other). To reduce risk of shock, this plug is
intended to fit in a polarized outlet only one way. If the
plug does not fit fully in the outlet, reverse the plug. If it
still does not fit, contact a qualified electrician. DO NOT
attempt to defeat this safety feature.
A loose fit between the plug (receptacle) and the
AC outlet may cause overheating and a distortion
of the plug. Contact a qualified electrician to replace
loose or worn receptacles.
Do not sit, stand or place any heavy objects on the
appliance.
Do not submerge the main body in water or other
liquids.
Disconnect power supply before servicing.
Persons who are not familiar with the instructions
for use, as well as children and persons under the
influence of medication, alcohol, or drugs are not
permitted to operate the appliance, or are only per-
mitted to operate it under supervision.
To protect health safety and proper humidifier function
use only clean, contamination-free, cold, fresh tap
water in your humidifier. If your water source is contam-
inated or if you are uncertain of its safety use distilled
water. In addition, it is advised to clean and maintain
your humidifier in a timely manner as instructed in
this manual.
The use of water additives, such as ethereal/essential
oils, fragrances, eucalyptus, water conditioners etc.,
damages the tank material and as a consequence
the whole unit. Any use of such additives will void the
manufacturer’s warranty.
Remark: Neither humans nor animals can hear the high
frequency vibrations.
PLEASE READ AND SAVE ALL THESE INSTRUCTIONS!
7
en
5
1
3
1ft
4ft
3ft
7
96
2
4
8
8
en
Foreword
Congratulations on choosing the Ultrasonic humidifier
7135!
Did you know that dry room air:
Causes the membranes in your respiratory system to
dry out, and also causes chapped lips and stinging
eyes?
Encourages infections and illnesses of respiratory
system?
Causes weariness, tiredness and poor concentration?
Stresses household pets and house plants?
Encourages the formation of dust and the electrostatic
charging of textiles made of synthetic fibers, carpets
and plastic flooring?
Damages furnishings made of wood and parquet?
Detunes musical instruments?
General information
A comfortable atmosphere indoors is reached with a rela-
tive humidity level between 40 and 60%. Your humidifier
automatically controls the humidity level according to
desired setting. If the air is too dry, the humidifier will auto-
matically switch on. As soon as the desired humidity level
is reached, it will switch off.
Unpacking
Carefully remove the humidifier from the box. Place
your hands underneath the product to pull it out of the
box (10).
Warning: Do not take the unit out of the box by pulling
up on the tank handle – base may fall and will be
damaged (11).
Warning: The mist outlet is packed in a red bag inside
the box insert. Make sure that you remove the mist
outlet from the packaging (12).
Remove the plastic bag from the humidifier.
Observe the information given on the rating plate about
the voltage.
Use the original packaging for storing the appliance if
you do not use the humidifier all year round.
10
11
12
9
en
Setting up
Finding the ideal location for your unit:
Do not place the humidifier directly next to a heating
vent or on a floor with floor heating. The moisture of
the mist can damage the floor surface (6) (see Safety
Instructions).
The unit should be placed in an elevated position (7),
e.g. on a table, chest, etc. at least 3 ft off the floor.
The mist outlet must not be pointed directly at plants,
furniture, or other objects (13). Keep distance of at
least 20 inches (50 cm).
Please refer to the enclosed manual for putting the
A250 AQUA PRO into operation.
Read the instructions under «Filling the tank» for
adding water in the humidifier (14 and 15).
Place the water tank onto the base.
Insert the plug into the socket and switch on the
appliance using the on/off button (18).
About 10 to 15 minutes after it is switched on the
device will reach its full output level.
Make sure that the cable is not pinched anywhere (9).
Do not operate the humidifier if the cable is damaged
(2).
Membrane
Control panel
Air inlet
Mist outlet (rotating)
A250 AQUA PRO
Water tank
Evaporation chamber
Brush
Water base
Power plug
Water level sensor
Main body
Description of the appliance
Water tank cap
Hydro Cell
13
10
en
16
17
15
14
Filling the tank
Always unplug the unit before removing the
water tank. Do not touch the water in the base
during operation!
To protect health safety and proper humidi-
fier function use only clean, contamination-free,
cold, fresh tap water in your humidifier. If your
water source is contaminated or if you are uncertain of its
safety use distilled water.
Do not operate the humidifier when the water tank is
empty! When the water reaches the minimum level, the unit
switches off the nebulizer function automatically. The red
light comes on indicating tank is empty.
Remove the water tank from the base and unscrew the
water tank cap (14). Caution: the mist outlet is loose!
Make sure that no foreign objects are in the water
tank.
Fill the tank with clean, cold water from the tap (15).
Close the cap of the water tank securely, place the
water tank onto the base (16). The water is now
running from the tank into the base.
Do not pour water into the mist outlet of the appliance
(17).
Insert the plug into the socket and switch on the
appliance using the on/off button (18). The red empty
indicator light may stay illuminated for some seconds
until the base is filled with water.
Do not use additives
Water additives (ethereal/essential oils, fragrances,
eucalyptus, water conditioners, etc.) must not be used!
Even a small amount can cause cracks in the material. The
material isn’t made for the use of such additives. One drop
is enough to damage the tank and as a consequence the
unit. Any use of such additives will void the manufacturer’s
warranty.
18
11
en
C) Timer
Using button C, the operation time can be set adjust-
able between 1 and 9 hours or co (continious operation).
Symbol G shows the operating period that has been set
(1h/2h/3h/4h/5h/6h/7h/8h/9h/co). The display will automat-
ically show the current value after a few seconds.
D) Mist output (regulating mist output)
The mist output can be regulated by pressing button
D several times. If the red bars are displayed, you have
selected the highest level of mist output (symbol H).
E) Operation with water pre-heating
(warm mist)
Button E is used for switching the pre-heating on and off
(symbol I lights up). As a result, the water is pre-heated
to a temperature of 176 °F (80 °C) before entering the
nebulizer space. It takes approx. 10 to 15 minutes for the
water in the base to warm up. The mist now leaves the
humidifier at a pleasant temperature of 104 °F (40 °C). The
advantage of this is that the room temperature does not
drop and, in addition, it significantly improves the water
quality maintenance.
F) Automatic mode and Sleep mode
The automatic and sleep modes can be activated by press-
ing button F. By pressing the button once, the automatic
function is switched on (symbol J appears on the display),
maintaining the optimum humidity subject to the tempera-
ture. Control takes place by means of output quantity and
pre-set target value. If the sleep function is switched on
(the symbol K appears on the display), the target humidity
is 60%; the operation time is automatically set at 8 hours;
the heating is switched on. In addition, the output quantity is
also controlled subject to the difference between the target
value and the actual value.
The Timer cannot be changed in either mode. If other but-
tons are pressed, the unit will no longer be in auto or sleep
mode.
A) On / Off button
You can switch the unit on or off by pressing button A. This
button is also used to reset the cleaning indicator light (by
holding down).
B) Hygrostat (setting the humidity level)
By pressing button B you can set the desired humidity
level in %. A relative humidity between 40% and 60%
is recommended. The accuracy of measurement is +/- 5%.
The unit will switch off when the moisture level exceeds the
desired setting. The device does not switch off if the dis-
play is set to «Co» (continuous operation). During selection
the target value is displayed. The display will automatically
show the current value after a few seconds.
Operation 7135 G) Timer Indicator
H) Mist Output Indicator
I) Pre-heating Indicator
J) Automatic Mode Indicator
K) Sleep Mode Indicator
L) Empty indicator
The water level is easy to see, thanks to the transparent
water tank. The appliance also alerts you when the water
tank is empty. The empty indicator is illuminated (symbol L).
Please read the chapter «Filling the tank» for more informa-
tion. The symbol L may stay illuminated for some seconds
with a refilled tank until the base is filled with water.
M) Cleaning indicator
If symbol M and «CLEAN» appear on the display, the appli-
ance should be cleaned as recommended by the manufac-
turer. This symbol comes on automatically every 2 weeks,
depending on the level of use. The display can be reset
by holding down button A until the light disappears.
A
BC
DEF
M
LG
HIKJ
12
en
ACID
WARM
WARM
21
2420
23
Cleaning/Maintenance
Always unplug the unit before removing the
water tank. Do not touch the water in the base
during operation!
Caution – risk of electric shock and
damage of the product!
Switch off the appliance and unplug it from the socket
before cleaning it (19).
Clean the water tank and the base regularly. Use water
only, no detergents (20).
Use EZCal and EZCal PRO custom cleaning and desca-
ling agents only to remove deposits from the memb-
rane regularly (21 and 22). There is a sample of EZCal
included in the packaging of your humidifier. Instruc-
tions for using are on the packet. Only use 1 packet for
32 oz of water. Do not change the ratio. Do NOT run the
unit when using EZCal and EZCal PRO. This can cause
damage to the product and voids the warranty. Tho-
roughly rinse the base with tap water after using EZCal
and EZCal PRO and make sure no EZCal and EZCal
PRO residues remains in the base.
22
19
25
13
en
26
Water quality maintenance
The Hydro Cell keeps humidifiers operating at their highest
level between recommended cleanings. Good for approxi-
mately one to two months, depending on the water quality,
the Hydro Cell ensures the humidifier’s functionality while
providing fresh humidification performance. It starts to
work as soon as it comes in to contact with water, even if
the unit is turned off. The Hydro Cell should be changed every
one to two months*. Look at picture 26/27 for the position
of the Hydro Cell in the water tank of the unit. Switch off
the unit first. Contact your local retailer or check our website
www.boneco.us for reorder information.
* Depending on the water quality.
EZCal and EZCal PRO are the only recommended
cleaning and descaling solutions. Do NOT use
any other cleaning solutions since it can damage
the product. Any use of cleaning solutions apart
from EZCal and EZCal PRO will void the warranty.
Make sure main body is never submerged in water
(23)!
The cleaning indicator still appears on the display after
cleaning. To reset it hold down the ON/OFF button until
the clean light stops flashing.
Clean the inner parts with a soft cloth. Do not use any
solvents or aggressive cleaning agents to clean the
appliance (24).
Only use the brush to clean the membrane. This should
be done once a week. Only use the soft-bristle portion
of the brush (25).
Change the water in the tank at least once a week if
water is standing for more than a week.
27
14
en
Technical data
Electrical voltage 120 V / 60 Hz
Power consumption up to 45 W / (140W*)
Humidity output up to 3.5 gallons / 24 h*
Suitable for rooms up to 650 sq ft / 60 m
2
Dimensions (LxWxH) 15 x 8.7 x 13.8 in
38 x 22 x 35 cm
Weight (empty) 7.7 lbs / 3.5 kg
Accessories A250 AQUA PRO
Hydro Cell A200
EZCal A7417
EZCal PRO A100
* when used with pre-heating to 176 °F (80 °C)
Storing the appliance for extended periods
Clean the appliance as described earlier and allow to dry
thoroughly. Preferably store the appliance in its original box,
in a dry place away from high temperatures.
Legal notice
The humidifier is cUL-listed.
Subject to technical change. The instructions for use are
protected by copyright © BONECO AG.
Accessories
Contact your local retailer or check our website
www.boneco.us for re-order information.
Customer Service
Customer Service (USA) 1-800-336-0326
www.boneco.us
Troubleshooting
Problem Possible cause What to do
Unit does not operate Power cable not plugged in Plug in power cable
No water in the tank (Empty indicator on) Fill tank with water and wait 10 min.
No mist output Unit needs cleaning Descale the water base using EZCal and EZCal PRO
A250 AQUA PRO exhausted Replace A250 AQUA PRO
Weak mist output Water temperature too low Set mist output to maximum, after 15 min.
the humidifier will work properly again
Mineral deposits on membrane Clean membrane using EZCal and EZCal PRO and brush
Unit running intermittently Replace A250 AQUA PRO
White dust around the humidifier A250 AQUA PRO exhausted
15
en
General Humidifier Questions
Q. Why isn’t there enough moisture in my room?
A. How often do you run the unit? If the unit is only run at
night, then during the day the moisture level will drop if
moisture is not constantly added to the air.
Q. Do you leave your door open or closed when the
unit is running?
A. a) By leaving the door open, this allows moisture to
leave the room and go into other areas of the house.
If you would like the moisture to stay within one
specific room you should consider closing the door
while the unit is running.
b) Wood, leather, carpet, curtains, and other types of
fabric soak up a lot of moisture, thus not leaving
enough moisture for the air. If the window is left
open, then this allows moisture to escape the room.
Another factor is a lot of times the unit is placed
next to a heating device. The idea is that the air
blowing into the room will quickly place moisture
around the room. Unfortunately, this concept does
not work because the hot air coming out of a vent
will soak up most of the moisture, and none of the
air within the room will receive any.
Q. How much moisture do I need in my room?
A. Suggested humidity levels are between 40 – 60%.
Q. What are the effects of too little or too much
humidity?
A. Dry air can cause dry skin, static electricity, out of tune
musical instruments, increased levels of dust (dry air
causes dust to rise), damage to wooden objects
(dry out and eventually cracks appear), discomfort,
sickness, and dries out nasal membranes.
Over-humidifying the air can cause mold and wallpaper
to peel.
Q. Why do I need a humidifier when I can just open
my window?
A. The moisture level within the outside air is not high
enough to humidify a room. The colder the air the less
moisture it is capable to hold, and the more the air is
heated up the percentage of relative humidity is lower.
Relative humidity means the amount of water vapor in
the air, compared to the amount the air could hold if it
was totally saturated. The difference is higher between
outside and inside temperatures; more humidification
is needed because of the dry air in the room.
Q. Where should I place my humidifier?
A. The unit should be free-standing and not close to a
wall, window, door, or thermal bridge so that air may
circulate around the unit.
Ultrasonic Frequent Questions
Q. There is no fill-line on the water tank, how far
may I fill it up?
A. There is no fill line on the water tank, and it may be
filled all the way to the top.
Q. Is it ok to use distilled water with the unit?
A. For best results with your ultrasonic humidifier use
distilled or reverse-osmosis water.
Q. The directions tell me not to place the unit directly
on the floor, why do I have to elevate the unit?
A. The idea with this unit is to allow one to force humidity
into the air. Because of this, the carpeting or wood floor
surrounding the unit may become damp. If the unit is
placed at least 3 feet off the floor, the mist will have the
opportunity to evaporate before hitting the floor.
Q. Water does not go into the tank.
A. In order to fill the tank, it must be turned upside down.
The cartridge is placed on the water tank cap. Do not
pour water in the tube which is the mist outlet.
Q. White dust is emitted from the unit
A. White dust particles are minerals that are broken up in
tiny pieces by the ultrasonic process.
Solve the problem:
Don’t use water from a pre-installed water softener,
or sodium instead of calcium will be emitted from the
unit. Use distilled water instead.
For very hard water areas use only distilled water.
Use Reverse-Osmosis water (R-O water) instead of
distilled water.
Cleaning light is illuminated (digital models)
Switch off the unit and unplug it. Empty the water in the
base. Rinse the base with warm/clean water. Do not
submerge the base! Visually inspect the base for dirt or
mineral build up. If soft water is used decalcifying the unit
every 4 weeks with EZCal is suggested. If hard water is
used the unit should be decalcified every 2 weeks. Do not
forget to reset the clean light after resetting the unit.
Q. Reset cleaning light (digital models)
A. The cleaning light does not automatically reset. Hold
down the power button (button A in instruction manual)
until the light stops flashing. The light automatically
comes on approx. after 14 days of plugging in the unit.
Q. The hygrometer on unit reads a different humidity
level than external hygrometer.
A. Not all hygrometers are calibrated the same, and most
are off by +/- 5%. Plus the humidity level is not the
same in the whole room. The air circulation is different
in every corner of the room. The unit should not be
placed near a heating vent or a radiator as the heat will
absorb all of the moisture.
Q. Humidity level is not changing or does not reach
the desired humidity level.
A. If the water tank needs refilling more than once per
day, the unit is working properly and the climatic con-
dition in the room has an influence on the humidity.
16
en
Reasons for low humidity level:
air circulation is very high (air is fully exchanged
several times per day – the humidifier needs to starts
its work from scratch)
insulation of home (see air circulation)
open space with high ceilings (not only the footage of
the room counts but also the height) – high-rise buil-
dings require more humidification.
open windows – works similar to air circulation (if it
is very cold outside don’t open the window more than
2 times per day for 3 minutes)
big difference between outside temperature and inside
temperature – the colder the air the less moisture it
is capable to hold and the more the air is heated up
the lower is the percentage of relative humidity (=the
amount of water vapor in the air, compared to the
amount the air could hold if it was totally saturated)
position of the unit - if it is placed close to a door,
window or air vent. This increases the air circulation.
Q. Tank is leaking
A. Check if there are any hairline cracks. Dropped units or
water tanks that are cracked will not be covered under
the warranty. Please contact the retailer the unit was
purchased from in case your unit arrives damaged.
Q. Placing the face in the mist
A. It is not recommended that anybody places their face
in the mist. It is an electrical product and should not be
played with.
Q. No mist / unit is not working / empty indicator
keeps flashing
A. Fill up the water tank. Check if water is flowing through
the A250 AQUA PRO (attached to the water tank cap). If
the water tank is full but there is only little water in the
base it indicates that the water is now flowing through
the A250 AQUA PRO.
Wait for 15 minutes to allow the mist to come out of
the unit.
If the unit is not working and the empty light is not flas-
hing you might have set the desired humidity too low
and the current humidity level in the room is higher.
That is why the unit switches off automatically.
If the empty indicator keeps flashing and the tank is
full, the water is not flowing through the cartridge.
Exchange the A250 AQUA PRO after 2-6 months, in
areas with hard water exchange the cartridge after
1-2 months. However, the A250 AQUA PRO must be
exchanged at the latest after 6 months or the unit does
not reach its full performance anymore.
Q. Water tank cap is too tight to unscrew
A. This could be a cause of the air pressure within the
water tank. Depress the spring on the bottom of the
water tank cap to release air from the water tank.
Continue to do this until you are able to unscrew the
water tank cap.
Accessories
Q. Do I need to keep any parts before I replace the
A250 AQUA PRO?
A. Yes, always keep the water tank cap (this is the piece
that attaches the A250 AQUA PRO to the water tank).
Q. What is the Hydro Cell and how long is it good for?
A. The Hydro Cell keeps humidifiers operating at their
highest level between recommended cleanings*. Good
for approximately one to two months, depending on the
water quality, the Hydro Cell ensures the humidifier’s
functionality while providing fresh humidification
performance. It needs to be replaced every one to two
months*.
* Depending on the water quality.
Q. Placement of the Hydro Cell
A. Please see picture 26/27 for instructions.
Q. What is EZCal and EZCal PRO?
A. There is a sample packet of EZCal included in the
packaging of your humidifier. EZCal and EZCal PRO are
used for cleaning and descaling any of the humidifiers
and cleans mineral build-up. EZCal and EZCal PRO
are the only recommended cleaning and descaling
solutions. Do NOT use any other cleaning solutions
since it can damage the product. Any use of cleaning
solutions apart from EZCal and EZCal PRO will void the
warranty. Instructions for using are on the packet. Only
use 1 packet for 32 oz of water. Do not change the
ratio. It can also be used for other humidifier brands.
Thoroughly rinse the base with tap water and make
sure no EZCal and EZCal PRO residues remains in the
base! EZCal and EZCal PRO are available at selected
retail stores and online www.boneco.us.
Please refer to the enclosed manual for
putting the A250 AQUA PRO into operation.
17
fr
Instructions d’utilisation
18
fr
Consignes de sécurité importantes
Avant la mise en service, lisez attentive ment et entière-
ment les instructions, puis rangez soigneusement ces
dernières pour tout besoin ultérieur.
AVERTISSEMENT – N’utilisez l’appareil qu’à l’intérieur
et dans les conditions recommandées. Toute utilisation
non conforme est susceptible de mettre votre santé en
danger.
Ne branchez l’appareil qu’au courant alternatif – la
tension doit correspondre à celle indiquée sur la plaque
signalétique de l’appareil.
Les enfants n’ont pas conscience des risques liés à
l’utilisation d’appareils élec triques. Surveillez-les donc
en permanence lorsqu’ils se trouvent à proximité du
humi dificateur (image 1).
Ne mettez jamais l’appareil en service lorsqu‘un
câble ou une prise est détérioré (2), ni après des dis-
fonctionnements ou lorsque l‘appareil a été échappé
(3) ou autre dommage quelconque.
Les réparations d’appareils électriques ne doivent
être exécutées que par des experts autorisés (4). Des
réparations non professionnelles peuvent causer des
dangers considérables pour l’utili sa teur.
Ne posez l’humidificateur que sur une surface sèche
et plane (5).
Ne posez pas l’appareil directement sur le plancher
ni à côté du chauffage (6). Si la brume entre en contact
avec le plancher avant l’évaporation, la surface du
plancher peut être endommagée. Nous n’acceptons
aucune responsabilité pour les dommages en cas d’un
emplacement inapproprié de l’appareil.
L’appareil doit être posé en hauteur (7), par exemple
sur une table, une commode, etc.
Placez l’appareil à un endroit tel qu’il ne soit pas
facilement heurté par quiconque (8).
Débranchez toujours l‘appareil lorsqu‘il n‘est pas
utilisé.
L’humidificateur doit être mis en service uniquement
lorsqu‘il est entièrement assemblé.
Débranchez TOUJOURS la prise avant d‘enlever, de
remplir et de vider le réservoir d’eau; avant de nettoyer,
d’effectuer la maintenance, l’assemblage, le désas-
semblage des pièces et avant de déplacer l‘appareil.
Ne mettez pas les mains dans la chambre de vapori-
sation lorsque l’appareil fonctionne et émet de hautes
fréquences.
Ne mettez pas le cordon d’alimentation sous le tapis et
ne le couvrez pas par des moquettes. Placez le cordon
de sorte que personne ne puisse trébucher.
Ne débranchez jamais la fiche de la prise en tirant sur
le cordon ou lorsque vos mains sont mouillées.
N’utilisez pas l’appareil en présence de gaz ou de
vapeurs inflammables.
N’exposez pas l’appareil à la pluie, ne l’utilisez pas à
proximité de l’eau, dans une salle de bain, dans une
buan derie, ni dans toute autre pièce humide.
Utilisez uniquement l’appareil en position verticale.
Veillez à ce qu’aucun objet étranger ne pénètre dans
les ouvertures de ventilation ou d’évacuation. Cela
pourrait engendrer des chocs électriques ou endom-
mager l’appareil. Ne bloquez pas les sorties ni les
entrées d’air.
Ne versez pas d’eau dans la buse de brumisation de
l’appareil!
La fiche de cet appareil est polari sée (une lame est
plus large que l’autre). Afin de réduire les risques de
chocs électriques, cette fiche est conçue de fa çon à ne
pouvoir être introduite dans une prise que d’une seule
manière. Si la fiche ne s’insère pas totalement dans la
prise, retournez-la. Si elle ne s’insère toujours pas dans
la prise, con tactez un électricien qualifié. N’essayez
PAS de contourner ce dispositif de sécurité.
Une mauvaise adaptation entre la fiche et la prise
CA peut entraîner une surchauffe et une déformation
de la fiche. Contactez un électricien qualifié pour le
remplacement de toute prise lâche ou trop usée.
Ne montez pas, ne vous assoyez pas et ne posez pas
d’objets lourds sur l‘appareil.
Ne plongez jamais le boîtier principal dans de l’eau ou
d’autres liquides.
Retirez la fiche de la prise de courant avant d’effectuer
l’entretien.
Ne laissez pas les personnes qui n’ont pas pris
connaissance du mode d’emploi, les enfants et les
personnes sous l’effet de médicaments, d’alcool ou
de drogues manipuler l’appareil, ou bien, uniquement
sous votre surveillance.
Afin de protéger la santé et sécurité et la fonction
adéquate d‘humidification n‘utilisez que de l‘eau po-
table propre, froide, et exempte de contaminants dans
votre humidificateur. Si votre source d‘eau est conta-
minée ou si vous êtes incertain de son innocuité, veuil-
lez utiliser de l‘eau distillée. De plus, il est conseillé
de nettoyer et d‘entretenir votre humidificateur en
temps opportun, comme indiqué dans ce manuel.
L’utilisation d’additifs comme les huiles éthérées/
les huiles essentielles, les parfums, l’euca lyptus,
les adoucisseurs d‘eau, etc., peut endommager les
matériaux du réservoir et par conséquent, l’appareil
entier. Tout usage de ces additifs annulera la garantie
du fabricant.
Remarque : Ni les êtres humains ni les animaux ne
peuvent entendre les vibrations haute fréquence.
LISEZ ET CONSERVEZ TOUTES LES INSTRUCTIONS!
19
fr
en
5
1
3
1ft
4ft
3ft
7
96
2
4
8
20
fr
Avant-propos
Félicitations pour l‘achat de l‘humidificateur à ultrasons
7135!
Savez-vous qu’un air desséché:
provoque le dessèchement des muqueuses, des
gerçures aux lèvres et des irritations aux yeux?
favorise les infections et les maladies des voies
respiratoires?
mène à un état de lassitude ou de fatigue permanent
et à des pertes de concentration?
est néfaste pour les animaux domestiques et les
plantes d’intérieur?
favorise l’accumulation de poussière et accroît l‘électri-
cité statique des textiles, des tapis et des revêtements
de sol synthétiques?
endommage les meubles et certains parquets en bois?
désaccorde certains instruments de musique?
Renseignements généraux
Le climat ambiant est agréable quand l’humidité relative
de l’air se situe entre 40 % et 60 %. Votre humidificateur
contrôle automatiquement l’humidité désirée que vous
avez prédéterminée. Lorsque l’air est trop sec, il démarre
automatiquement. Lorsque le degré d’humidité désiré est
atteint, il s’arrête automatiquement.
Désemballage
Retirez l’humidificateur de la boîte avec soin (10).
Attention: Ne tirez pas l’appareil de la boîte par la
poignée du réservoir – la base pourrait tomber et être
endommagée (11).
Attention: La buse de brumisation est emballée dans
un sachet rouge à l’intérieur de la boîte. Assurez-vous
de bien la retirer de l’emballage (12).
Retirez le sac en plastique de l’humidificateur.
Observez les renseignements figurant sur la plaque
signalétique concernant l’alimentation principale.
Si vous n’utilisez pas l‘humidificateur pendant toute
l’année, rangez-le dans l’emballage d’origine.
10
11
12
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Boneco 7135 Manuel utilisateur

Catégorie
Humidificateurs
Taper
Manuel utilisateur

dans d''autres langues