Empire Heating Systems Gravity Wall Furnace (GWT50W) Le manuel du propriétaire

Taper
Le manuel du propriétaire

Ce manuel convient également à

Page 1
WARNING
If not installed, operated and maintained
in accordance with the manufacturer's
instructions, this product could expose you
to substances in fuel or from fuel combustion
which can cause death or serious illness.
WARNING
FIRE OR EXPLOSION HAZARD
If the information in these instructions is
not followed exactly, a re or explosion may
result causing property damage, personal
injury or loss of life.
Do not store or use gasoline or other
ammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier
from a neighbors phone. Follow
the gas suppliers instructions.
If you cannot reach your gas
supplier, call the re department.
Installation and service must be
performed by a qualied installer,
service agency or the gas supplier.
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
GRAVITY VENTED
DUAL WALL
FURNACE MODEL:
GWT-50W-2
INSTALLATION INSTRUCTIONS
AND OWNER’S MANUAL
37410-6-0620Page 2
SECTION PAGE
Important Safety Information ..................................................................................................................................... 3
Safety Information for Users of Propane Gas ........................................................................................................... 4
Introduction ............................................................................................................................................................ 5-6
Specications ............................................................................................................................................................ 6
Recommended Vent Conguration ........................................................................................................................... 7
Gas Supply ............................................................................................................................................................... 8
Clearances ............................................................................................................................................................... 9
Ventilation and Combustion Air ................................................................................................................................. 9
Location - All Models ................................................................................................................................................. 9
Rough-In Instructions ........................................................................................................................................... 9-10
Finishing Instructions ......................................................................................................................................... 10-11
Optional On/Off Device ........................................................................................................................................... 12
Lighting Instructions ................................................................................................................................................ 13
Vent Safety Shut-off System ................................................................................................................................... 14
Proper Main Burner Flame ...................................................................................................................................... 14
Proper Pilot Flame .................................................................................................................................................. 14
Troubleshooting ...................................................................................................................................................... 15
Parts List ................................................................................................................................................................. 16
How To Order Repair Parts ..................................................................................................................................... 16
Parts View .............................................................................................................................................................. 17
Optional Blower Installation Instructions ........................................................................................................... 18-19
Warranty .................................................................................................................................................................. 20
TABLE OF CONTENTS
37410-6-0620 Page 3
THIS IS A HEATING APPLIANCE
DO NOT OPERATE THIS APPLIANCE WITHOUT OUTER CASING INSTALLED.
Due to high temperatures the appliance should be
located out of trafc and away from furniture and
draperies.
Children and adults should be alerted to the hazards
of high surface temperatures and should stay away
to avoid burns or clothing ignition.
Young children should be carefully supervised when
they are in the same room as the appliance.
Clothing or other ammable material should not be
placed on or near the appliance.
Any safety screen or guard removed for servicing
an appliance must be replaced prior to operating
the appliance.
Keep burner and control compartment clean.
Installation and repair should be done by a
QUALIFIED SERVICE PERSON. The appliance
should be inspected before use and at least annually
by a qualified service person. More frequent
cleaning may be required due to excessive lint from
carpeting, bedding materials, etc. It is imperative
that control compartments, burners and circulating
air passageways of the appliance be kept clean.
DO NOT put anything around the furnace that will
obstruct the ow of combustion and ventilation air.
• DO keep the appliance area clear and free from
combustible material, gasoline and other ammable
vapors and liquids.
• DO examine venting system periodically and replace
damaged parts.
• DO make a periodic visual check of pilot and burners.
Clean and replace damaged parts.
DO NOT use this heater if any part has been under
water. Immediately call a qualied service technician
to inspect the heater and to replace any part of the
control system and any gas control which has been
under water.
This furnace must not be connected to a chimney
ue serving a separate solid-fuel burning appliance.
IMPORTANT SAFETY INFORMATION
37410-6-0620Page 4
Some people cannot smell well. Some people cannot smell the
odor of the chemical put into the gas. You must nd out if you
can smell the odorant in propane. Smoking can decrease your
ability to smell. Being around an odor for a time can affect your
sensitivity or ability to detect that odor. Sometimes other odors in
the area mask the gas odor. People may not smell the gas odor
or their minds are on something else. Thinking about smelling a
gas odor can make it easier to smell.
The odorant in Propane Gas is colorless, and it can fade under
some circumstances. For example, if there is an underground
leak, the movement of the gas through soil can lter the odorant.
Odorants in Propane Gas also are subject to oxidation. This fading
can occur if there is rust inside the storage tank or in iron gas pipes.
The odorant in escaped gas can adsorb or absorb onto or into
walls, masonry and other materials and fabrics in a room. That will
take some of the odorant out of the gas, reducing its odor intensity.
Propane Gas may stratify in a closed area, and the odor intensity
could vary at different levels. Since it is heavier than air, there may
be more odor at lower levels. Always be sensitive to the slightest
gas odor. If you detect any odor, treat it as a serious leak. Imme-
diately go into action as instructed earlier.
Propane is a ammable gas which can cause res and explo-
sions. In its natural state, propane is odorless and colorless.
You may not know all the following safety precautions which
can protect both you and your family from an accident. Read
them carefully now, then review them point by point with the
members of your household. Someday when there may not
be a minute to lose, everyone's safety will depend on knowing
exactly what to do. If, after reading the following information,
you feel you still need more information, please contact your
gas supplier.
Learn to recognize the odor of Propane Gas. Your local
Propane Gas Dealer can give you a "Scratch and Sniff" pam-
phlet. Use it to nd out what the propane odor smells like. If
you suspect that your Propane Gas has a weak or abnormal
odor, call your Propane Gas Dealer.
If you are not qualied, do not light pilot lights, perform ser-
vice, or make adjustments to appliances on the Propane
Gas system. If you are qualied, consciously think about the
odor of Propane Gas prior to and while lighting pilot lights or
performing service or making adjustments.
Sometimes a basement or a closed-up house has a musty
smell that can cover up the Propane Gas odor. Do not try to
light pilot lights, perform service, or make adjustments in an
area where the conditions are such that you may not detect
the odor if there has been a leak of Propane Gas.
Odor fade, due to oxidation by rust or adsorption on walls of
new cylinders and tanks, is possible. Therefore, people should
be particularly alert and careful when new tanks or cylinders
are placed in service. Odor fade can occur in new tanks, or
reinstalled old tanks, if they are lled and allowed to set too
long before relling. Cylinders and tanks which have been
out of service for a time may develop internal rust which will
cause odor fade. If such conditions are suspected to exist,
a periodic sniff test of the gas is advisable. If you have any
question about the gas odor, call your Propane Gas Dealer.
A periodic sniff test of the Propane Gas is a good safety
measure under any condition.
If, at any time, you do not smell the Propane Gas odorant and
you think you should, assume you have a leak. Then take the
same immediate action recommended above for the occasion
when you do detect the odorized Propane Gas.
If you experience a complete "gas out," (the container is un-
der no vapor pressure), turn the tank valve off immediately.
If the container valve is left on, the container may draw in
some air through openings such as pilot light orices. If this
occurs, some new internal rusting could occur. If the valve is
left open, then treat the container as a new tank. Always be
sure your container is under vapor pressure by turning it off
at the container before it goes completely empty or having it
relled before it is completely empty.
Do not operate electric switches, light matches, use your
phone. Do not do anything that could ignite the gas.
Get everyone out of the building, vehicle, trailer, or area. Do
that IMMEDIATELY.
Close all gas tank or cylinder supply valves.
Propane Gas is heavier than air and may settle in low areas
such as basements. When you have reason to suspect a gas
leak, keep out of basements and other low areas. Stay out
until reghters declare them to be safe.
Use your neighbor's phone and call a trained Propane Gas
service person and the re department. Even though you may
not continue to smell gas, do not turn on the gas again. Do
not re-enter the building, vehicle, trailer, or area.
Finally, let the service man and reghters check for escaped
gas. Have them air out the area before you return. Properly
trained Propane Gas service people should repair the leak,
then check and relight the gas appliance for you.
SOME POINTS TO REMEMBER
NO ODOR DETECTED - ODOR FADE
PROPANE GAS WARNING ODOR
If a gas leak happens, you should be able to smell the gas because of the odorant put in the Propane Gas.
That's your signal to go into immediate action!
SAFETY INFORMATION FOR USERS OF PROPANE GAS
37410-6-0620 Page 5
INTRODUCTION
Introduction
Vented wall furnace is shipped ready to install in a 2" x 4" stud wall,
with studs 16" (406mm) center to center. Always consult your local
Building Department regarding regulations, codes or ordinances
which apply to the installation of a vented wall furnace.
Instructions to Installer
1. Installer must leave instruction manual with owner after
installation.
2. Installer must have owner ll out and mail warranty card
supplied with furnace.
3. Installer should show owner how to start and operate furnace.
Warning:
Any change to this furnace or its control can be dangerous.
This is a heating appliance and any panel, door or guard
removed for servicing an appliance must be replaced prior
to operating the appliance.
To conserve Gas: Turn off pilot when heater is not in use.
General Information
This series is design certied in accordance with American National
Standard / CSA Standard Z21.86 and CSA 2.32 by the Canadian
Standards Association, as a Vented Wall Furnace and must be
installed according to these instructions.
Any alteration of the original design, installed other than as
shown in these instructions or use with a type of gas not
shown on the rating plate is the responsibility of the person
and company making the change.
Important
All correspondence should refer to complete Model No., Serial No.
and type of gas.
NOTICE: During initial ring of this furnace, its paint will bake out and
smoke will occur. To prevent triggering of smoke alarms, ventilate
the room in which the furnace is installed.
Installation in Residential Garages
Gas utilization equipment in residential garages shall be installed
so that all burners and burner ignition devices are located not less
than 18" (457mm) above the oor.
Such equipment shall be located, or protected, so it is not subject
to physical damage by a moving vehicle.
Qualied Installing Agency
Installation and replacement of gas piping, gas utilization equipment
or accessories and repair and servicing of equipment shall be
performed only by a qualied agency. The term "qualied agency"
means any individual, rm, corporation or company which either in
person or through a representative is engaged in and is responsible for
(a) the installation or replacement of gas piping or (b) the connection,
installation, repair or servicing of equipment, who is experienced in
such work, familiar with all precautions required and has complied
with all the requirements of the authority having jurisdiction.
Commonwealth of Massachusetts: The installation must be
made by a licensed plumber or gas tter in the Commonwealth
of Massachusetts.
The installation must conform to local codes or, in the absence of
local codes, with the National Fuel Gas Code ANSI Z223.1/NFPA
54* Natural Gas and Propane Installation Code, CSA B149.1.
*Available from the American National Standards Institute, Inc., 11
West 42nd St., New York, N.Y. 10036.
High Altitudes
For altitudes/elevations above 2,000 feet (610m), input ratings
should be reduced at the rate of 4 percent for each 1,000 (305m)
feet above sea level. Canadian High Altitudes for locations having
an elevation above mean sea level between 2,000 feet (610m) and
4,500 feet (1370m), the manifold pressure is to be decreased from
3.5" w.c. (.871kPa) to 3.0" w.c. (.747kPa) for Natural Gas and from
10.0" w.c. (2.49kPa) to 8.0" w.c. (1.992kPa) for Propane Gas.
Well Head Gas Installations
Some natural gas utilities use “well head” gas. This may affect
the Btu output of the unit and promote sooting. Units shall not be
converted to use well head gas.
37410-6-0620Page 6
MODEL GWT-50W
Input BTU/HR (KW/H) 50,000 (14.7)
Height 66 1/8" (1679mm) 71 7/8" (1826mm) with blower
Width 16" (406mm)
Depth (Out of wall) 6" (152mm)
Gas Inlet Pipe 1/2"
Vent Pipe Type B Oval 4" (102mm)
ACCESSORY
Blower Package GWTB2W
GWT-50 (SG,RB) Is a DUAL WALL Furnace. Warmed air is discharged into two rooms which share a common wall.
SPECIFICATIONS
INTRODUCTION (CONT'D)
CONVERSION KITS
Part Number Description Used On
17093 Propane to Natural GWT50W-2LP
17092 Natural to Propane GWT50W-2NAT
When an existing Category 1 heater is removed or replaced,
the original venting system may no longer be sized to
properly vent the attached appliances. Instructions shall
also indicate effects of an improperly sized venting system
(formation of condensate, leakage, spillage, etc.) and shall
specify the following test procedure:
WARNING
CARBON MONOXIDE POISONING HAZARD
Failure to follow the steps outlined below for each
appliance connected to the venting system being
placed into operation could result in carbon monoxide
poisoning or death.
The following steps shall be followed for each
appliance connected to the venting system being
placed into operation, while all other appliances
connected to the venting system are not in operation:
1. Seal any unused openings in the venting system.
2. Inspect the venting system for proper size and
horizontal pitch, as required in the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 or the Natural
Gas and Propane Installation Code, CSA B149.1
and these instructions. Determine that there is no
blockage or restriction, leakage, corrosion and
other deciencies which could cause an unsafe
condition.
3. As far as practical, close all building doors and
windows and all doors between the space in which
the appliance(s) connected to the venting system
are located and other spaces of the building.
4. Close replace dampers.
5. Turn on clothes dryers and any appliance not
connected to the venting system. Turn on any
exhaust fans, such as range hoods and bathroom
exhausts, so they are operating at maximum
speed. Do operate a summer exhaust fan.
6. Follow the lighting instructions. Place the appliance
being inspected into operation. Adjust the
thermostat so appliance is operating continuously.
7. Test for spillage from draft hood equipped
appliances at the draft hood relief opening after 5
minutes of main burner operation. Use the ame
of a match or candle.
8. If improper venting is observed during any of the
above tests, the venting system must be corrected
in accordance with National Fuel Gas Code, ANSI
Z223.1/NFPA 54 and/or Natural Gas and Propane
Installation Code, CSA B149.1.
9. After is has been determined that each appliance
connected
to the venting system properly vents
when tested as outlined above, return doors,
windows, exhaust fans, replace dampers and
any other gas-red burning appliance to their
previous conditions of use.
37410-6-0620 Page 7
NOTICE: No vent equipment supplied with furnace.
4" Oval (all parts purchase locally)
1. Type B-1 oval pipe
2. Single story type B-1 gas vents require a baseplate and one
pair of ceiling plate spacers.
3. Multi-story type B-1 gas vents require a baseplate, one pair
of ceiling plate spacers at the rst oor ceiling and one pair of
re stop spacers at each successive ceiling level.
Type B-W gas vent pipe is available for single story or
multi-story installations. Type B-W gas vent pipe is to
be used with the Listed base plate, ceiling plate spacers
and re stop spacers.
Insulated Vent Enclosure
Gravity vented wall furnaces installed in buildings with at roofs can
have poor venting. The cold vent pipe will have a delay in proper
venting and cause the wall furnace to shut "off" by the vent safety
switch. To prevent delayed venting as well as condensation of ue
products an insulated vent enclosure is recommended.
Use Type B vent pipe and maintain at least a one inch (25mm)
clearance to combustibles.
Use metal thimble to protect vent pipe as it passes through
combustibles.
Baseplate Gasket is factory installed on header. Baseplate attaches
to header with screws. B-vent snaps into and is attached to baseplate.
Minimum height of vent pipe must be six feet (1.8m) above header.
Stud space around gas vents must be free of obstructions and
building paper.
Uninsulated Single-Wall Metal Pipe shall not be used outdoors in
cold climates for venting gas utilization equipment.
Attention: The main burner uses room air for combustion. As the
gas/air mixture is injected into the main burner, there is also the
ow of dust and lint particles into the main burner.
Dust and lint accumulation inside the main burner will result in a
yellow main burner ame and possible sooting inside the combus-
tion chamber and vent pipe. To clean main burner refer to Page 14,
"Proper Main Burner Flame."
RECOMMENDED VENT CONFIGURATION
37410-6-0620Page 8
Check all local codes for requirements, especially for the size and
type of gas supply line required.
RECOMMENDED GAS PIPE DIAMETER
Pipe
Length
Schedule 40 Pipe
Inside Diameter
Tubing, Type L
Outside Diameter
Natural Propane Natural Propane
0-10 feet
0-3 meters
1/2”
12.7mm
3/8”
9.5mm
1/2”
12.7mm
3/8”
9.5mm
10-40 feet
4-12 meters
1/2”
12.7mm
1/2”
12.7mm
5/8”
15.9mm
1/2”
12.7mm
40-100 feet
13-30 meters
1/2”
12.7mm
1/2”
12.7mm
3/4”
19mm
1/2”
12.7mm
100-150 feet
31-46 meters
3/4”
19mm
1/2”
12.7mm
7/8”
22.2mm
3/4”
19mm
NOTICE: Never use plastic pipe. Check to conrm whether your
local codes allow copper tubing or galvanized.
NOTICE: Since some municipalities have additional local codes, it
is always best to consult your local authority and installation code.
Check all local codes for requirements, especially for the size and
type of gas supply line required. On Natural Gas lines less than 15'
(4.57m) long, use 1/2" pipe; on longer runs, use 3/4" iron pipe or
equal. On Propane Gas lines please consult Propane Gas supplier.
Installing a New Main Gas Shut-Off
Each appliance should have its own manual gas shut-off.
A manual main gas shut-off should be located in the vicinity of the
unit. Where none exists, or where its size or location is not adequate,
contact your local authorized installer for installation or relocation.
Compounds used on threaded joints of gas piping shall be resistant
to the action of liqueed petroleum gases. The gas lines must be
checked for leaks by the installer. This should be done with a soap
solution watching for bubbles on all exposed connections, and if
unexposed, a pressure test should be made.
Never use an exposed ame to check for leaks. Appliance must
be disconnected from piping at inlet of control valve and pipe
capped or plugged for pressure test. Never pressure test with
appliance connected; control valve will sustain damage!
A gas valve and ground joint union should be installed in the gas
line upstream of the gas control to aid in servicing. It is required by
the National Fuel Gas Code that a drip line be installed near the gas
inlet. This should consist of a vertical length of pipe tee connected
into the gas line that is capped on the bottom in which condensation
and foreign particles may collect.
Figure 1
The use of the following gas connectors is recommended:
ANS Z21.24 Appliance Connectors of Corrugated Metal Tubing
and Fittings
ANS Z21.45 Assembled Flexible Appliance Connectors of Other
Than All-Metal Construction
The above connectors may be used if acceptable by the authority
having jurisdiction. The Commonwealth of Massachusetts requires
that a exible appliance connector cannot exceed three feet in length.
Pressure Testing of the Gas Supply System
1. To check the inlet pressure to the gas valve, a 1/8" (3.175mm)
N.P.T. plugged tapping, accessible for test gauge connection,
must be placed immediately upstream of the gas supply
connection to the appliance.
2. The appliance and its individual shut-off valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of
1/2 psig (3.5 kPa).
3. The appliance must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig (3.5 kPa).
Attention! If one of the procedures results in pressures in excess
of 1/2 psig (14" w.c.) (3.5 kPa) on the appliance gas valve, it will
result in a hazardous condition.
Checking Manifold Pressure
Both Propane and Natural Gas valves have a built-in pressure
regulator in the gas valve. Natural Gas models will have a manifold
pressure of approximately 3.5" w.c. (.871kPa) at the valve outlet
with the inlet pressure to the valve from a minimum of 4.5" w.c.
(1.120kPa) for the purpose of input adjustment to a maximum of
10.5" w.c. (2.614kPa) Propane Gas models will have a manifold
pressure approximately 10.0" w.c. (2.49kPa) at the valve outlet
with the inlet pressure to the valve from a minimum of 11.0" w.c.
(2.739kPa) for the purpose of input adjustment to a maximum of
13.0" w.c. (3.237kPa).
A 1/8" (3.175mm) N.P.T. plugged tapping, accessible for test gauge
connection, is located on the outlet side of the gas control.
GAS SUPPLY
37410-6-0620 Page 9
1. In selecting a location for installation, it is necessary to provide
adequate accessibility clearances for servicing and proper
installation.
2. Clearances to combustible surfaces are 4" (102mm) from sides,
12" (305mm) to top, 1 1/2" (38mm) from oor.
NOTE: Minimum distance of 1 1/2" (38mm) must also be maintained
from top surface of carpeting, tile, etc.
Wall furnaces shall be installed in a location in which the facilities
for ventilation permit satisfactory combustion of gas and proper
venting under normal conditions. In buildings of conventional frame,
brick, or stone construction without tight storm windows and doors,
inltration is normally adequate to provide air for combustion and
draft hood dilution.
Where appliances are installed in conned and unconned spaces
within a building, the building being of unusually tight construction,
air for combustion and ventilation must be obtained directly from
outdoors or from such spaces that freely communicate with the
outdoors. Under these conditions, the conned and unconned
spaces shall be provided with two permanent openings, one near
the top of the enclosure and one near the bottom; each opening
shall have a free area of not less than one square inch (6.45cm
2
)
per 2,000 BTU (.6KW/H) per hour of total input.
Select a location near the center of the space to be heated. Overow
heat will circulate through doorways into adjacent rooms.
For large homes or spread-out oor plans, two or more furnaces are
recommended. Do not locate furnace where a door could swing
over the outer casing, or where circulation could be retarded by
furniture or cabinets.
Do not install in a closet, alcove or small hallway where the furnace
could be isolated by closing doors to the heated space.
When location is selected, check the walls, attic and roof to make
sure there are no obstructions such as pipes, electric wiring, etc.,
which would interfere with the installation of the furnace or vent pipe.
NOTE: If Optional Blower is to be used, hard wiring must be
completed for the optional blower prior to installation of
header plate.
Provide an opening in the wall 14 1/2" (368mm) wide and 66 1/8"
(168cm) high measured from top of oor plate (See Figure 2 and
Figure 3). Wall depth is to be 2" x 4" framing with 1/4" (6.5mm) to
5/8" (16mm) sheeting. Attach baseplate (not supplied with furnace)
to header plate with sheet metal screws at each end. Attach 4"
(102mm) oval, double wall vent pipe to baseplate. Attach enough vent
pipe so that when installed in wall opening the vent pipe will extend
above the ceiling plate by at least 6" (152mm). Install ceiling spacers
according to manufacturer's instructions. Two header extensions
are attached to the header plate. One header extension is welded
to the header plate and one header extension is screwed to the
header plate. To install header plate into wall opening remove the
header extension that is screwed to the header plate (2 screws).
Insert header plate with attached 4" oval, double wall vent pipe
into wall opening. Position header plate at height shown in Figure
2. Locate rear edge of nailing ange at the back of the 2" x 4" stud
which will center the vent collar in the wall. Locate the angled edge
of header plate ush with the top of the wall opening. Nail header
plate to the wall studs. Replace and attach header extension onto
header plate with 2 screws.
CLEARANCES
VENTILATION AND COMBUSTION AIR
LOCATION - ALL MODELS
ROUGH-IN INSTRUCTIONS
37410-6-0620Page 10
Plastering (Figure 4)
In new construction use only plain (not perforated) gypsum lath
around furnace and vent pipe so that plaster "Keys" will not project
into wall space.
Use wood strips nailed to inside of studs and top of bottom plate.
These must be removed before installation of furnace. Lath and
plaster against top projection of Header Plate.
Do not allow wall nish materials to project into furnace recess..
66 1/8”
(1679 mm)
WALL
OPENING
14 ½”
(368 mm)
Figure 4
Installing Furnace (Figure 5)
Clear the recess of all debris, and remove any wood plaster-grounds.
Stand the furnace on oor in front of wall opening.
Insert furnace ue into rectangular opening in header plate and
raise furnace carefully (see Figure 5). Swing bottom of furnace into
wall opening with back of legs ush with rear of oor plate. Secure
furnace support legs to the oor plate.
Figure 5
Figure 3
FINISHING INSTRUCTIONS
62 1/4”
(1581 mm)
14 ½”
(368 mm)
66 1/8”
(1679 mm)
WALL
OPENING
Figure 2
37410-6-0620 Page 11
IMPORTANT — Avoid securing too tightly and disturbing the inner
casing. Do not try to force furnace into a wall opening which is
smaller than specied dimension.
OUTER CASING (Figure 6)
1. Align 1 3/4" slot on casing bracket with bottom screw hole on
inner casing. Attach casing bracket to inner casing with one (1)
10 x 1/2" screws for each casing bracket. Do not completely
tighten screws at this time.
2. Place outer casing onto header.
Attention: Use center clearance hole on outer casing top for
attachment to header with one (1) 8 x 3/8" Phillips screw when
optional blower is not installed.
Attention: Use outside clearance holes on outer casing top
for attachment to header with two (2) 8 x 3/8" Phillips screws
when optional blower is installed.
3. Align clearance holes on outer casing bottom with screw holes
on casing brackets by adjusting slots on casing brackets.
4. Complete tightening casing bracket screws from Step 1 to inner
casing at this time.
5. Attach outer casing to casing brackets with two (2) 10 x 1-1/2"
screws.
INSTALLING CONTROL DOOR
Attach two washers supplied in hardware package to pivot pins
located at bottom of control door. Install control door to outer cas-
ing assembly.
Figure 6
FINISHING INSTRUCTIONS (CONT'D)
37410-6-0620Page 12
CAUTION — Do not run wire behind anges of Header Plate or in
any location where it might be damaged.
Millivolt wall on/off device is specially designed for use on self-
generating systems. They should never be used on line or low
voltage A.C. circuits.
Installing the ON/OFF Device
To install an ON/OFF device (such as a wall switch, remote, toggle
switch,or thermostat), remove the wire nut from the two wires
from the valve. Run additional wire from the valve wires to the
ON/OFF device. Install the ON/OFF device in the same room as
the furnace following the installation instructions supplied with it.
In the absence of instructions, install the ON/OFF device 4 to 5
feet above the oor on an interior wall not affected by another
heating source (i.e. stove or water heater) or the temperature of
an adjoining room.
Proper operation depends on a good pilot ame. The ame must
cover the top of the thermopile. Cleaning of the pilot orice and
burner may be required due to spiders.
System Check (Figure 7)
A millivolt meter is required to check the system. Millivolt readings
should be:
Across the thermopile terminals, 400-450 millivolts with heater
OFF.
Across the thermopile terminals, 150-250 millivolts with heater
ON.
Across the heater wires at the valve, less than 30 millivolts with
heater ON.
To conserve Gas: Turn off pilot when heater is not in use.
OPTIONAL ON/OFF DEVICE(SG MODELS)
TO VENT SAFETY
TO THERMOPILE
TO VENT SAFETY
TO THERMOPILE
TO OPTIONAL
THERMOSTAT
Figure 7
TO OPTIONAL
ON/OFF DEVICE
37410-6-0620 Page 13
LIGHTING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the oor because some
gas is heavier than air and will settle on the oor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your building.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the re
department.
C. Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or turn
by hand, don't try to repair it; call a qualied service
technician. Force or attempted repair may result in a re
or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualied service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
TO TURN OFF GAS TO APPLIANCE
1. Turn off all electric power (if applicable) to appliance if
service is to be performed.
2. Remove control access panel (control door).
3. Push in gas control knob slightly and turn clockwise
to "OFF." Do not force.
4. Replace control access panel (control door).
1. STOP! Read the safety information above.
2. Turn off all electric power to the appliance (if applicable).
3. Remove control access panel (control door).
4. Push in gas control knob slightly and turn clockwise
to "OFF."
NOTE: Knob cannot be turned from "PILOT" to "OFF"
unless knob is pushed in slightly. Do not force.
5. Wait ten (10) minutes to clear out any gas. Then smell
for gas, including near the oor. If you smell gas, STOP!
Follow "B" in the safety information above. If you don't
smell gas, go to the next step.
6. Find pilot - follow metal tube from gas control. The pilot
is mounted on front of main burner.
7. Turn gas control knob counterclockwise
to "PI-
LOT."
8. Push in control knob all the way and
hold in. Immediately light the pilot with
a match. Continue to hold the control
knob in for about one (1) minute after
the pilot is lit. Release knob and it will
pop back up. Pilot should remain lit. If
it goes out, repeat steps 5 through 9.
If knob does not pop up when released, stop and imme-
diately call a qualied service technician or gas supplier.
If the pilot will not stay lit after several tries, turn the gas
control knob to "OFF" and call your service technician
or gas supplier.
9. Turn gas control knob counterclockwise
to "ON."
10. Replace control access panel (control door).
11. Turn on all electric power to the appliance (if applicable).
GAS CONTROL KNOB SHOWN IN "OFF" POSITIONGAS CONTROL KNOB SHOWN IN "OFF" POSITION
LIGHTING INSTRUCTIONS
WARNING
If you do not follow these instructions exactly, a re or explosion may result causing property damage,
personal injury or loss of life.
37410-6-0620Page 14
This appliance must be properly connected to a venting system. This
appliance is equipped with a vent safety shutoff system.
Warning: Operation of this wall furnace when not connected
to a properly installed and maintained venting system or
tampering with the vent safety shutoff system can result in
carbon monoxide (CO) poisoning and possible death.
This furnace is equipped with a manual reset vent safety switch. The
manual reset vent safety switch will cause gas ow to the main burner
to "shut off" due to improper venting or a blocked ue.
To reset the manual reset vent safety switch:
1. Remove outer casing.
2. Depress manual reset button. The manual reset vent safety switch
is located on the draft diverter.
3. Replace outer casing.
If the manual reset vent safety switch continues to "shut off" the gas
ow to the main burner a qualied service person must be contacted to
inspect for improper venting, blockage in the vent pipe or the manual
reset vent safety switch for being defective.
The correct ame will be a short blue inner ame with a much larger light
blue outer ame. The burner does not have a primary air adjustment.
The ame will be proper if the factory-set pressure and orice are used.
After the furnace has begun operating, cleaning of the burner may be
needed for proper ame, examine at least 2 times per season.
To clean burner ports, disconnect the gas supply to the valve. Remove the
burner assembly from the combustion chamber. Remove pilot burner from
main burner and then remove the main burner. Force water into the ports
and blow dry with vacuum cleaner air, or low pressure compressed air.
Figure 9
Figure 10
The correct ame will be blue, extending past the thermopile. The ame
will surround the thermopile just below its tip.
Natural Gas pilots require adjusting when the inlet gas pressure is above
5" w.c. (1.245kPa). Remove the pilot cover screw on the control valve
and turn the adjustment screw clockwise to reduce ame. Replace
pilot cover screw to eliminate gas leaking at that control valve opening.
Propane Gas will not require adjustment.
After use, cleaning may be required for the proper ame.
Examine the pilot ame before and during each heating season.
Figure 8
VENT SAFETY SHUTOFF SYSTEM
PROPER MAIN BURNER FLAME
PROPER PILOT FLAME
WIRES FOR
ON/OFF DEVICE
37410-6-0620 Page 15
GENERAL: All furnaces have been re-tested to check for proper
operation. This includes main burner ame, pilot ame, and gas
control operation. If the furnace fails to function on initial installation,
it is advisable to re-check the following:
1. Inlet gas pressure.
2. Type of gas being used and that shown on the rating plate.
Contact your Empire Dealer to assist in servicing furnace.
Servicing the Pilot and Main Burner, Pilot Orice, Thermopile
and Main Burner Orice
Disconnect the gas supply at the inlet to the control valve. Remove
the burner assembly to which the above components are attached.
Pilot Does Not Light
With air in the gas line, such as when the furnace is rst installed
or was "OFF" all summer, the pilot ame may be too lean to ignite
on the rst few trials. Turn the gas control knob to PILOT position
and depress the gas control knob. Hold the gas control knob down
to bleed the line;
1. Use lighter rod to light pilot with a match.
If Pilot Does Not Light By Any Means
1. Check gas control knob for being in the "Pilot" position.
2. Check pilot adjustment for being full open (counterclockwise
to open).
3. If gas is available in the supply tubing, the pilot orice and/
or pilot burner is probably restricted by a spider web. Clean
pilot assembly and relight.
If Pilot Does Not Remain "On" After Releasing Gas Control Knob
1. Follow instructions and hold gas control knob down longer
and harder.
2. Determine if pilot ame extends past thermopile; if not, adjust
pilot ame or clean pilot burner.
3. Replace thermopile if millivolt reading is less than 300 millivolts
when wall mounted on/off device or remote bulb is turned
OFF. Replace gas control if magnet dropout millivolt reading
is over 100 millivolts.
Pilot Outage During Normal Operation
1. Check input by manifold pressure gauge or gas meter.
2. Check millivolt output when furnace is in operation. If millivolt
output decreases during furnace operation gas control may
be defective.
Main Gas Valve Does Not Open When ON/OFF Device Is
Turned "On"
1. Check millivolt output of thermopile.
2. Device wires may be broken.
3. Device may be defective.
TROUBLESHOOTING
37410-6-0620Page 16
Empire Comfort Systems, Inc. Belleville, Illinois
USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.
ATTENTION: When ordering parts, it is very important that part number and description of part coincide.
Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts
through the distributor. Parts can be shipped directly to the service person/dealer.
All parts listed in the Parts List have a Part Number. When ordering parts, rst obtain the Model Number from the name plate on your
equipment. Then determine the Part Number (not the Index Number) and the Description of each part from the following appropriate
illustration and list. Be sure to give all this information.
Furnace Model Number
Part Description
Furnace Serial Number Part Number
Type of Gas (Propane or Natural)
Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store.
Shipments contingent upon strikes, res and all causes beyond our control.
PARTS LIST
HOW TO ORDER REPAIR PARTS
INDEX
NO.
PART
NO.
DESCRIPTION
1 WFA-115 HEADER GASKET
2 36324
HEADER ASSEMBLY
(INCLUDES NO. 1, GASKET)
3 GWT-184 INNER CASING ASSEMBLY
4 GWT-151 DIVERTER ASSEMBLY (2 REQUIRED)
5 GWT-020 FRONT SHIELD (2 REQUIRED)
6 GWT-077 HEAT SHIELD (2 REQUIRED)
7 36328
CASING FRONT ASSEMBLY
(2 REQUIRED) (INCLUDES #11)
8 GWT-186 CASING BRACKET (4 REQUIRED)
9 36321
CASING DOOR ASSEMBLY
(2 REQUIRED)
10 R-885 NYLON WASHER (4 REQUIRED)
11 R-3763 MAGNET (4 REQUIRED)
12 DV-064 COVER PLATE (2 REQUIRED)
13 GWT-008
BURNER COMPARTMENT FRONT
(2 REQUIRED)
14 R-3046 VENT SAFETY SWITCH
15 R-3038-A ECO LEAD ASSEMBLY
16 26466 EXCHANGER ASSEMBLY - REAR
17 26465 EXCHANGER ASSEMBLY - FRONT
18 R-3036 PILOT - NATURAL GAS
18 R-3037 PILOT - PROPANE GAS
19 R-1054 THERMOPILE
20 GWT-096 BURNER BRACKET ASSEMBLY
21 R-5245 GAS VALVE - NATURAL GAS
21 R-5246 GAS VALVE - PROPANE GAS
22 R-3031 BURNER (6 REQUIRED)
23 P-88-55
BURNER ORIFICE - NATURAL GAS
(6 REQUIRED)
23 P-88-65
BURNER ORIFICE - PROPANE GAS
(6 REQUIRED)
24 GWT-014
AIR SHUTTER FRONT - PROPANE
GAS (2 REQUIRED)
25 GWT-015
AIR SHUTTER REAR -
PROPANE GAS (2 REQUIRED)
26 GWT-054
AIR SHUTTER BOTTOM -
PROPANE GAS (2 REQUIRED)
27 23906 VALVE SHIELD
28 36354
CASING ASSEMBLY COMPLETE
(INCLUDES #7, #9 AND TWO #10)
29 24752 LOWER SHIELD
30 29011 EXCHANGER TUBE SUPPORT
NOT
SHOWN
GWT-099 PILOT TUBING W/FERRULES
NOT
SHOWN
R-3178
PILOT ORIFICE (HONEYWELL K14
.014 PROPANE GAS ONLY)
NOT
SHOWN
R-3179
PILOT ORIFICE (HONEYWELL A26
.026 NATURAL GAS ONLY)
NOT
SHOWN
R-734 MATCH HOLDER
NOT
SHOWN
GWT-190
HARDWARE PACKAGE
(2 REQUIRED)
INDEX
NO.
PART
NO.
DESCRIPTION
37410-6-0620 Page 17
PARTS VIEW
7
5
6
4
8
9
10
13
16
22
23
24
25
26
20
22
23
26
25
24
21
19
18
9
27
10
11
12
13
17
8
15
14
6
5
7
4
3
2
1
28
12
29
30
30
37410-6-0620Page 18
OPTIONAL BLOWER INSTALLATION INSTRUCTIONS
Installing Blower Using Three-Prong Plug
1.
Install furnace according to Installation Instructions and Owner's
Manual.
2. Refer to Drawing for measurements to locate two mounting holes
on wall surface above furnace.
On Solid Wall
3a. After locating mounting holes, attach two #10 x 1 1/2-inch screws
provided in blower kit into wall. Do not completely tighten screwheads
to wall, leave a 7/16-inch gap between screwheads and wall.
On Sheet Rock Wall
3b. After locating mounting holes, drill two 5/16-inch diameter holes
into wall. Insert the two plastic expansion anchors into holes. Insert
two #10 x 1 1/2-inch screws provided in blower kit into two plastic
expansion anchors. Do not completely tighten screwhead to plastic
expansion anchors, leave a 7/16-inch gap between screwheads
and plastic expansion anchors. Refer to Figure 12.
4. At the top of outer casing remove one screw from center clearance
hole that attaches outer casing to header assembly. Also, remove
two screws that attach bottom of outer casing to inner casing.
5.
Pull the outer casing forward approximately 1 inch away from
wall surface.
6. Remove four 8 x 3/8-inch screws that attach blower front to blower
housing. Separate blower front from blower housing. Remove
blower housing by disconnecting fan switch wire assembly from
power cord and motor wire.
Caution: When removing blower front be careful not to damage
motor coil wires. Damaged coil wires will disable blower function.
7.
Position blower housing on top of header assembly and route three-
prong cord set between left side of outer casing and inner casing.
Caution: Blower cord set routing is important. Cord set should
be in proper location to avoid being overheated. Incorrect routing
of cord set may result in damage to cord set.
8. Replace the outer casing to the wall surface.
9. Attach outer casing to header assembly. Attention: The center
clearance hole will not be used. The two outside clearance holes
will be used to attach outer casing to header assembly, one screw
from Step 4 and one screw supplied in hardware package. Refer
to Figure 11.
Figure 11
10. Attach outer casing to inner casing with two screws from Step 4.
11. Align key hole slots on back of blower housing with the two screws
attached to wall. Position blower housing ush with wall surface
and on top of outer casing. Complete tightening blower housing
screws from Step 3a or 3b to wall.
12. Attach caps and plugs from blower housing and blower front.
13. Attach blower front to blower housing with four 8 x 3/8-inch screws
from Step 6.
14. Installation of optional blower assembly is completed.
Caution: When installing blower housing onto wall be careful
motor coil is not damaged.
Installing Blower With Hard Wiring
1. When facing the wall opening, install 120 volt electrical outlet
junction box inside wall opening on left wall stud approximately
12 inches above header plate.
2. Refer to Drawing for measurements to locate access hole for
electrical wiring on wall surface.
3. After locating access hole, drill a 1/2-inch hole into wall.
4.
Route enough eld wiring from 120 volt electrical outlet junction box
through 1/2 inch access hole in wall for connection to blower housing.
5. Install furnace according to Installation Instructions and Owner's
Manual.
6. Refer to Drawing for measurements to locate two mounting holes
on wall surface above the furnace.
On Solid Wall
7a. After locating mounting holes, attach two #10 x 1 1/2-inch screws
provided in blower kit into wall. Do not completely tighten screwheads
to wall, leave a 7/16-inch gap between screwheads and wall.
On Sheet Rock Wall
7b. After locating mounting holes, drill two 5/16-inch diameter holes
into wall. Insert two plastic expansion anchors into holes. Insert
two #10 x 1 1/2-inch screws provided in blower kit into two plastic
expansion anchors. Do not completely tighten screwhead to plastic
expansion anchors, leave a 7/16-inch gap between screwheads
and plastic expansion anchors. Refer to Figure 12.
Figure 12
8. Remove three prong cord set from blower housing.
9. Remove four 8 x 3/8-inch screws that attach blower front to blower
housing. Separate blower front from blower housing. Remove
blower housing by disconnecting fan switch wire assembly from
power cord and motor wire.
10. Position blower housing on top of header assembly.
11. Route 120 volt eld wiring into blower housing through cord set
hole on back of blower housing.
12. Refer to wiring diagram to make wiring connections inside blower
housing. Be sure to follow all local and National electrical codes
when making eld wiring connections.
13. Align key hole slots on back of blower housing with two screws
attached to wall. Position blower housing ush with wall surface
and on top of outer casing. Complete tightening blower housing
screws from Step 7a or 7b to wall.
14. Attach caps and plugs from blower housing and blower front.
15. Attach blower front to blower housing with four 8 x 3/8-inch screws
from Step 9.
16. Installation of optional blower assembly is completed.
GWTB2W-1 FOR MODELS
GWT-25W, GWT-35W, GWT-50W
37410-6-0620 Page 19
Fan Control
The automatic fan control is located on the bottom of the blower
assembly. The fan control is a nonadjustable, automatic type. The
fan control will require between 3 and 7 minutes of main burner
operation before the fan control "closes" and activates the blower.
The blower will continue to run between 3 and 7 minutes after the
main burner shuts off, before the fan control "opens" and deactivates
the blower.
Wiring
The appliance, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical
Code, CSA C22.1, if an external electrical source is utilized. This
appliance is equipped with a three-prong [grounding] plug for
your protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle. Do
not cut or remove the grounding prong from this plug. For an
ungrounded receptacle, an adapter, which has two prongs and a
wire for grounding, can be purchased, plugged into the ungrounded
receptacle and its wire connected to the receptacle mounting screws.
With this wire completing the ground, the appliance cord plug can
be plugged into the adapter and be electrically grounded.
WARNING:
Unplugging of blower accessory will not stop the heater
from cycling. To shut heater off, turn knob on gas control
to "OFF", depressing slightly. Do not force.
CAUTION: Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
Oiling
The blower motor does not have oiling holes. Do not attempt to oil
the blower motor.
13”
(330 mm)
4 7/16”
(112.6 mm)
Figure 13
GWTB2W WIRING DIAGRAM
PARTS LIST
INDEX
NO.
PART
NUMBER
DESCRIPTION
1 R2204 CORD SET
2 R1468 STRAIN RELIEF BUSHING
3 36334 BLOWER HOUSING ASSEMBLY
4 R1454 BRASS BUSHING (4 REQUIRED)
5 36338 BLOWER SIDE (2 REQUIRED)
6 R3085 WIRE ASSEMBLY
7 R2503 FAN SWITCH
8 36337 BLOWER FRONT
9 R1499
RUBBER GROMMET (4 REQUIRED)
10 R2804 BLOWER MOTOR
37410-6-0620Page 20
www.empirecomfort.com
Empire Comfort Systems Inc.
Belleville, IL
If you have a general question
about our products, please e-mail
If you have a service or repair
question, please contact your dealer.
WARRANTY
Empire Comfort Systems Inc. warranties this space heating product to be free from defects at the time of purchase and for the periods
specied below. Space heating products must be installed by a qualied technician and must be maintained and operated safely, in
accordance with the instructions in the owner’s manual. This warranty applies to the original purchaser only and is not transferable. All
warranty repairs must be accomplished by a qualied gas appliance technician.
Limited Ten-Year Parts Warranty – Combustion Chamber
Empire promises to the owner that if the combustion chamber (see parts list) fails because of defective workmanship or
material with ten years from the date of purchase, Empire will repair or replace at Empire’s option.
Limited One-Year Parts Warranty – Remote Controls, Accessories, and Parts
Should any remote control, accessory, or other part fail because of defective workmanship within one year from the date of
purchase, Empire will repair or replace at Empire’s option.
Duties Of The Owner
The appliance must be installed by a qualied installer and operated in accordance with the instructions furnished with the
appliance. A bill of sale, cancelled check, or payment record should be kept to verify purchase date and establish warranty
period. Ready access to the appliance for service.
What Is Not Covered
Damages that might result from the use, misuse, or improper installation of this appliance.
Travel, diagnostic costs and freight charges on warranted parts to and from the factory.
Claims that do not involve defective workmanship or materials.
Unauthorized service or parts replacements.
Removal and reinstallation cost.
Inoperable due to improper or lack of maintenance.
How To Get Service
To make a claim under this warranty, please have your receipt available and contact your installing dealer. Provide the dealer
with the model number, serial number, type of gas, and purchase verication. The installing dealer is responsible for providing
service and will contact the factory to initiate any warranted parts replacements. Empire will make replacement parts available
at the factory. Shipping expenses are not covered.
If, after contacting your Empire dealer, service received has not been satisfactory, contact: Consumer Relations Department,
Empire Comfort Systems Inc., PO Box 529, Belleville, Illinois 62222, or send an e-mail to [email protected] with
“Consumer Relations” in the subject line.
Your Rights Under State Law
This warranty gives your specic legal rights, and you may also have other rights, which vary from state to state.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Empire Heating Systems Gravity Wall Furnace (GWT50W) Le manuel du propriétaire

Taper
Le manuel du propriétaire
Ce manuel convient également à