This manual must only be used by a quali ed installer / service technician. Read all instructions in this
manual before installing. Perform steps in the given order. Failure to do so could result in substantial
property damage, severe personal injury, or death.
The manufacturer reserves the right to make product changes or updates without notice and will not be
held liable for typographical errors in literature.
NOTE TO CONSUMER: PLEASE KEEP ALL INSTRUCTIONS FOR FUTURE REFERENCE.
The surfaces of these products contacted by potable (consumable) water contain less than 0.25% lead
by weight as required by the Safe Drinking Water Act, Section 1417, and are certi ed as such by IAPMO.
California Proposition 65 Warning: This product contains chemicals known to the State of California to
cause cancer, birth defects, or other reproductive harm.
$'9(57(1&,$
Este manual es para uso exclusivo de instaladores y técnicos de servicio cuali cados. Lea todas las instrucciones
proporcionadas en este manual antes de llevar a cabo la instalación. Realice los pasos en las secuencias indicadas.
De lo contrario, podrían producirse daños materiales signi cativos, lesiones graves o incluso la muerte.
AVIS2
El fabricante se reserva el derecho a realizar modi caciones o actualizaciones al producto sin necesidad
de previo aviso, y no puede considerarse responsable por errores tipográ cos en la documentación.
NOTA AL CONSUMIDOR: CONSERVE TODAS LAS INSTRUCCIONES PARA FUTURAS CONSULTAS.
Las super cies de estos productos que entran en contacto con agua potable contienen menos del
0,25% de plomo en peso, tal y como lo requiere la Ley de seguridad sobre el agua potable de los Estados
Unidos, sección 1417, y están certi cadas como tales por IAPMO.
Advertencia conforme a la Proposición 65 de California: Este producto contiene sustancias químicas que,
conforme al estado de California, producen cáncer, defectos de nacimiento u otros daños reproductivos.
AVERTISSEMENT
Ce manuel doit être utilisé uniquement par un installateur / technicien de maintenance quali é. Lire toutes les instructions
de ce manuel avant de procéder à linstallation. E ectuer les opérations dans l’ordre indiqué. Tout non-respect de cette
consigne peut entraîner des dégâts matériels considérables, des dommages corporels graves voire la mort.
AVIS
Le fabricant se réserve le droit d'apporter des modi cations ou des mises à jour sur le produit sans
préavis et pourra être tenu pour responsable des erreurs typographiques dans la documentation.
REMARQUE À LATTENTION DU CLIENT: VEUILLEZ CONSERVER TOUTES LES INSTRUCTIONS POUR Y FAIRE RÉFÉRENCE ULTÉRIEUREMENT.
Les surfaces de ces produits en contact avec de l'eau potable (consommable) contiennent moins de 0,25% de plomb
en poids, comme l'exige la Loi sur la salubrité de l'eau, Section 1417, et sont certi ées comme telles par l'IAPMO.
Avertissement Proposition 65 de la Californie: Ce produit contient des produits chimiques reconnus par l'État de
Californie pour provoquer des cancers et des malformations congénitales ou autres problèmes de reproduction.
2
EN
3
EN
The following de ned terms are used throughout this manual to bring attention to the presence of hazards of
various risk levels or to important product information.
DANGER indicates an imminently hazardous situation which, if not avoided, will result in serious personal injury
or death.
WARNING indicates a potentially hazardous situation which, if not avoided, could result in personal injury or
death.
CAUTION indicates a potentially hazardous situation which, if not avoided, may result in moderate or minor
personal injury.
CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not
avoided, may result in property damage.
NOTICE is used to address practices not related to personal injury.
Foreword
This manual is intended to be used in conjunction with other literature provided with the water heater. This
includes all related control information. It is important that this manual, all other documents included in this
system, and additional publications be reviewed in their entirety before beginning any work.
Installation should be made in accordance with the regulations of the Authority Having Jurisdiction, local code
authorities, and utility companies which pertain to this type of water heating equipment.
Authority Having Jurisdiction (AHJ) – The AHJ may be a federal, state, local government, or individual such as a
re chief,  re marshal, chief of a  re prevention bureau, labor department or health department, building o cial
or electrical inspector, or others having statutory authority. In some circumstances, the property owner or his/
her agent assumes the role, and at government installations, the commanding o cer or departmental o cial
may be the AHJ.
NOTE: The manufacturer reserves the right to modify product technical speci cations and components without
prior notice.
For the Installer
This water heater must be installed by quali ed and licensed personnel. The installer should be guided by the
instructions furnished with the water heater, and by local codes and utility company requirements.
Installations Must Comply With:
Local, state, provincial, and national codes, laws, regulations, and ordinances.
The latest version of the National Electrical Code, NFPA No. 70.
Table of Contents
Part 1 - General Safety Information 4
A. When Servicing the Water Heating System 5
B. Heater Water 5
C. Freeze Protection 5
D. Water Temperature Adjustment 6
Part 2 - Prepare the Water Heater 6
A. Model Overview 6
B. Locating the Water Heater 6
C. Water Chemistry Requirements 7
D. Technical Speci cations and Dimensions 9
Part 3 - Installation Instructions 9
A. Mounting the Water Heater 9
1. Wall Mounting 9
2. Floor Mounting 9
B. Plumbing 9
C. Thermal Expansion 10
D. Condensation 10
E. Temperature and Pressure Relief Valve 10
F. Scalding 11
G. Filling the Heater 12
Part 4 - Electrical Connection 12
Part 5 - Installation Checklist 13
Part 6 - Operation 13
A. Starting and Testing 13
B. Thermostat Adjustment 13
Part 7 - Maintenance 13
A. Removing the Cover 14
B. Draining the Heater 14
C. Removing the Heating Element 14
D. Inspecting the Anode Rod 14
E. Descaling the Heating Element 15
SPECIAL ATTENTION BOXES
4
EN
Part 1 - General Safety Information
This water heater is approved for indoor installations only and is not intended for use as a pool heater. Heater
must have room for service: 24” front, 6” top, 1” left side, 3” right side, and 0” bottom are minimum recommended
service clearances. (A combustible door or removable panel is acceptable front clearance.) This water heater
has been approved for closet installation and installation on combustible  ooring. Do not install directly on
carpeting. Install the water heater in a location where temperature and pressure relief valve discharge or a leak
will not result in damage to the surrounding area. If such a location is not available, install an auxiliary catch pan.
NOTE: Obey all local codes. Obtain all applicable permits before installing the water heater.
NOTE: Install all system components and piping in such a manner that does not reduce the performance of any
re rated assembly.
The manufacturer cannot be responsible for damages caused by improper installation or by failure to follow the
instructions in this manual.
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions to reduce the risk of  re, electric shock, or injury to
persons should be followed, including:
1. READ ALL INSTRUCTIONS BEFORE USING THIS WATER HEATER.
2. This water heater must be grounded. Connect only to a properly grounded outlet. See Part 4 – Heater Wiring,
this manual, for grounding details.
3. Install or locate this water heater only in accordance with the provided installation instructions.
4. Use this water heater only for its intended use as described in this manual.
5. Models 2.5 and 4 come equipped with a power cord. Do not use an extension cord set with this water heater.
If no receptacle is available adjacent to the water heater, contact a quali ed electrician to have one properly
installed. Model 8 must be hard-wired. See installation instructions for details.
6. As with any appliance, close supervision is necessary when used by children.
7. Do not operate this water heater if it has a damaged cord or plug, if it is not working properly, or if it has been
damaged or dropped.
8. This water heater should be serviced only by quali ed service personnel. Contact the water heater installer or
a quali ed service agency for examination, repair, or adjustment.
9. Failure to inspect the anode rod at least once a year could cause the tank to fail and leak. This condition is not
covered under the manufacturer’s warranty.
SAVE THESE INSTRUCTIONS
Installer - Read all instructions in this manual before installing. Perform steps in the given order.
User - This manual is for use only by a quali ed heating installer / service technician. Have this water heater
serviced / inspected annually by a quali ed service technician.
FAILURE TO ADHERE TO THE GUIDELINES ON THIS PAGE CAN RESULT IN SUBSTANTIAL PROPERTY
DAMAGE, SEVERE PERSONAL INJURY, OR DEATH.
NOTE: If the water heater is exposed to the following, do not operate. Immediately call a quali ed service
technician.
1. Fire
2. Damage
3. Water
Failure to follow this information could result in property damage, severe personal injury, or death.
Part 8 - Troubleshooting 15
A. Resetting the High Limit Switch 16
B. Checking Thermostat Operation 16
C. Changing the Heating Element 16
D. Changing the Thermostat 16
Part 9 - Replacement Parts 17
Mini Tank Electric Water Heater Limited Warranty 18
Customer Installation Record Form 20
5
EN
High heat sources (sources generating heat 100
o
F / 37
o
C or greater, such as stove pipes, space heaters, etc.) may
damage plastic components of the water heater as well as plastic vent pipe materials. Such damages ARE NOT
covered by warranty. It is recommended to keep a minimum clearance of 8” from high heat sources. Observe
heat source manufacturer instructions, as well as local, state, provincial, and national codes, laws, regulations
and ordinances when installing this water heater and related components near high heat sources.
Hydrogen gas can be produced in a hot water system served by this heater that has not been used for a long
period of time (generally 2 weeks or more). Hydrogen gas is extremely  ammable. To reduce the risk of injury
under these conditions, it is recommended that the hot water faucet be opened for several minutes at the
kitchen sink before using any electrical appliance connected to the hot water system. If hydrogen gas is present,
there will probably be an unusual sound such as air escaping through the pipe as the water begins to  ow. There
should be no smoking or open  ame near the faucet at the time it is open. Failure to follow these instructions
will result in serious personal injury or death.
A. When Servicing the Water Heating System
To avoid electric shock, disconnect electrical supply before performing maintenance.
NOTE: When inquiring about service or troubleshooting, reference the model and serial numbers from the water
heater rating label.
To avoid severe burns, allow water heater and associated equipment to cool before servicing.
B. Heater Water
Do not use petroleum-based cleaning or sealing compounds in a water heating system. Gaskets and seals in the
system may be damaged. This can result in substantial property damage.
Do not use “homemade cures or “patent medicines”. Damage to the water heater, substantial property damage,
and/or serious personal injury may result.
C. Freeze Protection
NOTE: Consider piping and installation when determining heater location.
Failure of the water heater due to freeze related damage IS NOT covered by product warranty.
NEVER use any toxic chemical, including automotive, standard glycol antifreeze, or ethylene glycol made for
hydronic (non-potable) systems. These chemicals can attack gaskets and seals in water systems, are poisonous
if consumed, and can cause personal injury or death.
UNCRATING THE WATER HEATER - Any claims for damage or shortage in shipment must be  led immediately
against the transportation company by the consignee.
Be sure to disconnect electrical power before performing service. Failure to do so could result in electrical shock,
property damage, serious personal injury, or death.
Tank failure due to neglecting the anode rod is not covered under warranty. See Maintenance, this manual.
DO NOT USE THIS WATER HEATER IF ANY PART HAS BEEN SUBMERGED IN WATER. Immediately call
a quali ed service technician. The water heater MUST BE replaced if it has been submerged. Attempting to
operate a water heater that has been submerged could create numerous harmful conditions, such as a potential
gas leakage causing a  re and/or explosion, or the release of mold, bacteria, or other harmful particulates into
the air. Operating a previously submerged water heater could result in property damage, severe personal injury,
or death.
NOTE: Water heater damage due to  ood or submersion is considered an Act of God, and IS NOT covered under
product warranty.
Do not use this water heater for anything other than its intended purpose (as described in this manual). Doing
so could result in property damage and WILL VOID product warranty.
6
EN
D. Water Temperature Adjustment
The water heater thermostat has been pre-set at
the factory at a temperature equal to or below
125
o
F (51.7
o
C) according to UL certi cation. See
Figure 1. If the water heater is going to have a
set temperature above 120
o
F, it is recommended
to use an ASSE 1017 rated mixing valve to avoid
severe burns or death from scalding temperatures.
Figure 1 - Thermostat
Households with small children, disabled, or elderly persons
may require a 120
o
F or lower temperature setting to prevent
severe personal injury or death due to scalding.
Approximate Time / Temperature Relationships in
Scalds
120
o
F More than 5 minutes
125
o
F 1 1/2 to 2 minutes
130
o
F About 30 seconds
135
o
F About 10 seconds
140
o
F Less than 5 seconds
145
o
F Less than 3 seconds
150
o
F About 1 1/2 seconds
155
o
F About 1 second
Table 1 - Approx. Time / Temperature Relationships in Scalds
A. Model Overview
The following  gures detail speci c water heater model components. Some components may ship factory
installed. This depends on water heater model.
Part 2 - Prepare the Water Heater
Remove all sides of the shipping crate to allow the heater to be moved into its installation location.
COLD WEATHER HANDLING - If the water heater has been stored in a very cold location (BELOW 0
o
F) before
installation, handle with care until the components come to room temperature. Failure to do so could result in
damage to the water heater.
B. Locating the Water Heater
NOTE: After adjusting the water temperature at the thermostat, allow the water heater enough time to heat
the water to temperature. After the water heater has stopped heating, use a thermometer to measure the water
temperature at a hot water outlet in the structure.
This water heater is certi ed for indoor use only. DO NOT INSTALL OUTDOORS. Outdoor installations ARE NOT
covered by warranty. Failure to install the water heater indoors could result in property damage, severe personal
injury, or death.
All water heaters eventually leak. Locate the water heater where any leakage from the relief valve, related piping,
tank, or connections will not result in damage to surrounding areas or lower  oors of the building. Any water
heater should be installed in such a manner that if it should leak the resulting  ow of water will not cause
damage to the area in which it is installed. National Plumbing codes require a drain pan for any water heater
installation. Failure to install one is the sole responsibility of owner and/or installer. Reference UPC 2000 (Uniform
Plumbing Code) Section 510 - Protection from Damage or IPC 200 (International Plumbing code) Section 504 -
Safety Devices. Leakage damages ARE NOT covered by warranty.
In addition, water leak detection devices and automatic water shuto valves are readily available at plumbing
supply houses. IT IS HIGHLY RECOMMENDED BY THE MANUFACTURER TO INSTALL WATER LEAK DETECTION
DEVICES AND AUTOMATIC SHUTOFF VALVES IN ANY WATER HEATER INSTALLATION WHERE A LEAKAGE OF
WATER COULD RESULT IN PROPERTY DAMAGES.
1. Installation Area (Mechanical Room) Operating Conditions
Ensure ambient temperatures are higher than 32
o
F / 0
o
C and lower than 104
o
F / 40
o
C
Avoid continuously high levels of humidity
Never close existing ventilation openings
NOTE: When installing in a zero clearance location, it may not be possible to read or view some product labeling.
It is recommended to make note of the water heater model and serial number.
7
EN
2. Choose a location for the water heater as centralized to the piping and electrical system as possible. Also, locate
the water heater and domestic water piping where it will not be exposed to freezing temperatures. All piping
should be insulated. Additionally, place the water heater so that the drain, controls, and inlets/outlets are easily
accessible.
NOTE: To save on heating costs and improve energy e ciency keep the distance between the water heater and
xtures to a minimum to reduce heat loss from excess piping and keep friction loss at a minimum. Ensure all
water heater piping is properly insulated to minimize heat loss.
NOTE: If you do not provide the minimum recommended service clearances it might not be possible to service
the water heater without removing it from the space.
NOTE: In the State of California, the water heater must be braced, anchored, or strapped to avoid moving during
an earthquake. Contact local utilities for code requirements in your area. Visit http://www.dsa.dgs.ca.gov or call
1-916-445-8100 and request instructions.
3. Check area around water heater. Remove any combustible materials, gasoline, and other  ammable liquids.
This water heater must not be located near  ammable liquids such as gasoline, butane, lique ed propane,
adhesives, solvents, paint thinners, etc., as the controls of this water heater could ignite these vapors and cause
an explosion resulting in property damage, severe personal injury, or death.
This water heater must be installed upright in the vertical position as described in this manual. DO NOT attempt
to install this water heater in any other orientation. Doing so will result in improper water heater operation and
property damage, and could result in serious personal injury or death.
Incorrect ambient conditions can lead to damage to the heating system and put safe operation at risk. Ensure
that the installation location adheres to the information included in this manual. Failure to do so could result in
property damage, serious personal injury, or death.
4. If the water heater is to replace an existing water heater, check for and correct any existing system problems
such as:
• System leaks
Location that could cause the system and water heater to freeze and leak
Incorrectly-sized expansion tank
5. This water heater must be installed vertical on a level surface.
C. Water Chemistry Requirements
Chemical imbalance of the water supply may a ect e ciency and cause severe damage to the appliance and
associated equipment. Water quality must be professionally analyzed to determine whether it is necessary
to treat the water. Various solutions are available to adjust water quality. Adverse water quality will a ect the
reliability of the system. In addition, operating temperatures above 135
o
F will accelerate the build-up of lime
scale and possibly shorten appliance service life. Failure of an appliance due to lime scale build-up, low pH, or
other chemical imbalance IS NOT covered by the warranty.
NOTE: A combustible door or removable panel is acceptable front clearance.
The service life of the water heater’s exposed metallic surfaces, such as the junction box, is directly in uenced
by proximity to damp and salty marine environments. In such areas higher concentration levels of chlorides
from sea spray coupled with relative humidity can lead to degradation of water heater components and cause
premature water heater failure. Such failures ARE NOT covered by warranty.
Failure of the water heater or components due to incorrect operating conditions IS NOT covered by product
warranty.
The water must be potable, free of corrosive chemicals, sand, dirt, and other contaminates. It is up to the installer
to ensure the water does not contain corrosive chemicals or elements that can damage the heat exchanger.
Potable water is de ned as drinkable water supplied from utility or well water in compliance with EPA secondary
maximum contaminant levels (40 CFR Part 143.3). If the water contains contaminants higher than outlined by the
EPA, water treatment is recommended and additional, more frequent maintenance may be required.
If you suspect that your water is contaminated in any way, discontinue use of the appliance and contact an
authorized technician or licensed professional.
8
EN
Failure of electric elements due to lime scale build-up on the heating surface, low pH, or other imbalance IS NOT
covered by the warranty.
Water pH between 6.5 and 8.5
pH levels below 6.5 can cause an increase in the rate of corrosion. pH of 8.5 or higher can potentially cause
lime scale build-up
Maintain water pH between 6.5 and 8.5. Check with litmus paper or have it chemically analyzed by a local
water treatment company.
If the pH is not between 6.5 and 8.5, consult a local water treatment company for solutions.
Hardness between 4 grains (70 mg/L) and 20 grains (350mg/L):
The appliance must not be supplied with water of hardness less than 4 grains (70 mg/L), nor with especially
hard water (greater than 20 grains (350mg/L)); we recommend installing a water softener, properly calibrated
and controlled - do not allow the residual hardness to fall below 9 grains (150mg/L).
Chloride concentration less than 100 ppm (mg/L)
Do not  ll appliance or operate with water containing chlorides in excess of 100 ppm (mg/L).
Using chlorinated fresh water should be acceptable as levels are typically less than 5 ppm (mg/L).
Do not connect the appliance to directly heat swimming pool or spa water.
Total Dissolved Solids (TDS) less than 500 ppm (mg/L)
Total dissolved solids are minerals, salts, metals, and charged particles that are dissolved in water.
The greater the amounts of TDS present, the higher the corrosion potential due to increased conductivity
in the water.
If using softened water to  ll the appliance, it is still possible to have high TDS. This water can be corrosive.
Consult local water treatment companies for other treatment solutions to reduce this a ect.
Water conductivity not higher than 1200 μS / cm
*NOTE: To promote appliance service life, it is strongly recommended to follow the maintenance procedures in
this manual.
Figure 2 - Installation Detail
VALVE
CHECK VALVE
EXPANSION TANK
HOT WATER OUTLET
CATCH PAN
UNION
COLD WATER INLET
TEMP/PRESSURE
SHUT-OFF VALVE
DRAIN
RELIEF VALVE
MIXING VALVE
DRAIN
BALL VALVE
AUTOMATIC WATER
WATER LEAK
DETECTION
SENSOR
LP-665-D
07/31/18
NOTES:
1. Minimum pipe size should
match connection size. Upsize
pipe accordingly if greater  ow
is required.
2. A thermal expansion tank
suitable for potable water must
be sized and installed within
this piping system between
the back ow preventer and the
cold water inlet.
3. All circulators should have an
integral  ow check.
4. Drains and check valve
between unit and storage tank
will assist in purging air from
system.
5. These drawings are meant
to demonstrate system piping
only. The installer is responsible
for all equipment and detailing
required by local codes. In
Massachusetts, you must install
a vacuum relief valve per 248
CMR.
6. Mixing valve application is
optional, but recommended to
help prevent scalding. See Part
3 for more information.
7. It is highly recommended by the manufacturer to install water leak detection devices and automatic shuto valves in
any water heater installation where a leakage of water could result in property damages.
9
EN
Table 2 - Technical Speci cations - *Nipple Adaptors Included in the Box
D. Technical Speci cations and Dimensions
Technical Data Units 2.5 4 8
Tank Capacity Gallons 2.7 4.0 8.0
Dimensions Inches
14
1/4
”W x
14
1/4
”H x 10
3/4
”D
14
1/4
”W x
14
1/4
”H x 12
3/4
”D
17
1/2
”W x
17
1/2
”H x 15
1/4
”D
Weight (Empty) lbs 15.5 17.6 29.5
Maximum Water Pressure psi 150
Recovery Rate (90
o
F Rise) gal/h 6.8 6.8
Temperature Range
o
Fahrenheit 65 - 161 65 - 161
Water Connections NPT 1/2” NPT
3/4” NPT Nipple
Adapters Included*
Relief Valve Installed Installed
Included, not
Installed
Nominal Voltage (1 Phase) VAC 110 / 120 (all Models)
Nominal Current Amps 12.0
Power at 120 VAC Watts 1440
Electrical Connection Plug In Hard Wired
A
AE
F
B
C
D
A
B
C
6
D
E
11
F
Figure 3 - Dimensional Drawing
Part 3 - Installation Instructions
A. Mounting the Water Heater
These water heaters are designed to be installed under the sink.
1. Wall Mounting
Fasten the supplied mounting bracket to the wall.
Hang the water heater on the bracket.
Tug down on the water heater to ensure that both “ ngers” of the bracket are seated in the mounting slots.
2. Floor Mounting
The water heater can be installed on the  oor. Install the included adhesive rubber  oor mounting feet onto the
bottom of the water heater. See the rubber feet installation instructions included in the pack.
B. Plumbing
It is mandatory that all plumbing be done in accordance with federal, local, and state plumbing codes and
practices. Failure to properly install the water heater WILL VOID the warranty. It is also necessary to use both
thread tape and pipe dope on all mechanical plumbing connections.
Install unions on the hot and cold water connections to easily disconnect the water heater for servicing.
Use screws suitable for the wall material and the weight of the water heater. Failure to do so could result in
property damages and damage to the water heater. Such damages ARE NOT covered by product warranty.
10
EN
Failure of electric elements due to lime scale build-up on the heating surface, low pH, or other imbalance IS NOT
covered by the warranty.
C. Thermal Expansion
A check valve may be installed in the cold water inlet line as a separate back ow preventer, or may be part of
a pressure reducing valve, water meter, or water softener. An open water system refers to a system without a
check valve. A closed water system refers to a system with a check valve installed in the cold water inlet line.
As water is heated, it expands in volume and increases pressure within the water system. This action is referred
to as thermal expansion. In an open water system, expanding water which exceeds the capacity of the system
ows back into the city main where pressure is easily dissipated.
A closed water system prevents expanding water from  owing back to the city main. The resulting thermal
expansion can rapidly increase pressure in the water heater and system piping. This rapid pressure increase
can exceed the setting of the pressure relief valve, causing it to operate during each heating cycle, resulting
in discharge from the T&P. This rapid and repeated expansion and contraction of components in the system
can cause premature failure of system components, including the relief valve and possibly the water heater.
Replacing the relief valve will not correct thermal expansion.
There are two recommendations to prevent this from happening:
1. Install a potable diaphragm-type hot water expansion tank to o set thermal expansion. Expansion tanks
are designed with an air cushion built in that compresses as system pressure increases, thereby relieving the
overpressure condition and eliminating repeated operation of the relief valve. This expansion tank should be
installed in the cold water line between the water heater and check valve, and must be sized for the entire water
volume of the hot water system. The expansion tank must have a minimum capacity of 1.5 gallons for every 50
gallons of stored water.
2. Install a 125 PSI pressure relief valve in the cold water supply line. Make sure the discharge of this valve is
directed to an open drain and protected from freezing. Contact the local water supplier or plumbing inspector
for information on how to control this situation. Do not plug the temperature and pressure relief valve.
Other methods of controlling thermal expansion are available. Check with the local water utility to determine
if a check valve exists in the cold water inlet line. Contact your installing contractor, water supplier, or
plumbing inspector for additional information regarding thermal expansion.
D. Condensation
Condensation can form on the water heater when it is  rst lled with water, and may also occur with a heavy
water draw and very cold inlet water temperature. This condition is not unusual and will disappear as the water
becomes heated. However, if the condensation should continue, examine the piping and  ttings for possible
leaks.
NOTE: Insulating both the cold water inlet and hot water outlet pipes will reduce the opportunity for condensation
on the water heater piping.
E. Temperature and Pressure Relief Valve
For protection against excessive pressures and temperatures in this water heater, install the supplied temperature
and pressure relief valve certi ed by a nationally recognized testing laboratory that maintains periodic inspection
of production listed equipment or materials, as meeting the requirements for Relief Valves and Automatic Gas
Shuto Devices for Hot Water Supply Systems, ANSI Z21.22B / CSA 4.4-M99. The supplied temperature and pressure
relief valve is marked with a maximum set pressure (150 psi) that does not exceed the marked maximum working
pressure of the water heater (150 psi). Install the T&P valve in the opening provided and marked for this purpose
on the water heater, and orient it or provide tubing so that any discharge from the valve will exit at least 6” above
the structural  oor. The relief line cannot be in contact with any live electrical parts. The discharge opening must
not be blocked or reduced in size under any circumstances.
National Plumbing codes require a drain pan for any water heater installation. Failure to install one is the sole
responsibility of owner and/or installer. Reference UPC 2000 (Uniform Plumbing Code) Section 510 - Protection
from Damage or IPC 200 (International Plumbing code) Section 504 - Safety Devices.
Connect the cold water inlet pipe to the inlet tapping (marked with a blue ring).
Ensure an isolation valve is installed on the cold water supply to the water heater.
Connect the hot water outlet pipe to the outlet tapping (marked with a red ring).
Do not apply heat to the Hot or Cold water heater connections. If sweat connections are used, sweat tubing to
the adapter before  tting adapter to the water connections on the heater. Any heat applied to the water heater
connections will permanently damage the dip tube and/or heat traps. Damages due to improper installation
practices ARE NOT covered by warranty.
11
EN
RE-INSPECTION OF T&P RELIEF VALVES: T&P valves must be inspected AT LEAST ONCE EVERY THREE
YEARS, and replaced if necessary, by a licensed plumbing contractor or quali ed service technician to ensure
that the product has not been a ected by corrosive water conditions and to ensure that the valve and discharge
line have not been altered or tampered with illegally. Certain naturally occuring conditions may corrode the
valve and its components over time, rendering the valve inoperative. Such conditions can only be detected if
the valve and its components are physically removed and inspected. Do not attempt to conduct an inspection
on your own. Contact your plumbing contractor for a re-inspection to assure continued safety.
FAILURE TO RE-INSPECT THE T&P VALVE AS DIRECTED COULD RESULT IN UNSAFE TEMPERATURE AND/
OR PRESSURE BUILD-UP WHICH CAN RESULT IN PROPERTY DAMAGE, SERIOUS PERSONAL INJURY, OR
DEATH.
F. Scalding
This water heater can deliver scalding water. Be careful whenever
using hot water to avoid scalding injury. Certain appliances such as
dishwashers and automatic clothes washers may require increased
water temperatures. By setting the thermostat on this heater to obtain
the increased water temperature required by these appliances you
may create the potential for scald injury.
To protect against injury, install a mixing valve in the water system. This
valve will reduce point of use discharge temperatures by mixing cold
and hot water in branch supply lines. Such valves are available from
your local plumbing supplier.
Table 3 details the relationship of water temperature and time with
regard to scald injury and may be used as a guide in determining the
safest water temperature for your applications.
To avoid water damage or scalding due to relief valve operation:
Discharge line must be connected to relief valve outlet and run to a safe place of disposal. Terminate the
discharge line in a manner that will prevent possibility of severe burns or property damage should the relief
valve discharge.
Discharge line must be as short as possible and the same size as the valve discharge connection throughout
its entire length.
Discharge line must pitch downward from the valve and terminate at least 6” above the  oor drain, making
discharge clearly visible.
The discharge line shall terminate plain, not threaded, with a material serviceable for temperatures of 375
o
F
or greater.
Do not pipe discharge to any location where freezing could occur.
No valve may be installed between the relief valve and heater or in the discharge line. Do not plug or place
any obstruction in the discharge line.
Test the operation of the relief valve after  lling and pressurizing the system by lifting the lever. Make sure
the valve discharges freely. If the valve fails to operate correctly, immediately replace with a new properly
rated relief valve.
Test T&P valve at least once annually to ensure the waterway is clear. If valve does not operate, turn the
heater “o and call a plumber immediately.
Take care whenever operating relief valve to avoid scalding injury or property damage.
FAILURE TO COMPLY WITH THE ABOVE GUIDELINES COULD RESULT IN FAILURE OF RELIEF VALVE OPERATION,
RESULTING IN POSSIBILITY OF SUBSTANTIAL PROPERTY DAMAGE, SEVERE PERSONAL INJURY, OR DEATH.
Do not thread a cap or plug into the relief valve or relief valve line under any circumstances! Explosion and
property damage, serious injury, or death may result.
12
EN
An ASSE 1017 or ASSE 1070 temperature limiting or mixing valve is recommended in installations servicing
disabled or elderly persons, or children. Mixing valves do not eliminate the risk of scalding.
To avoid scalding:
Set the water heater set point temperature as low as possible.
Feel water before bathing or showering.
If thermostatic valves are required, use devices speci cally designed for such purpose. Install these devices
in accordance with instructions provided by the manufacturer.
Failure to install a temperature limiting or mixing valve and follow these instructions could result in property
damage, severe personal injury, or death due to scalds.
G. Filling the Heater
Make certain any drain valves in the system are completely closed.
Open the shut-o valve in the cold water supply line.
Open the hot water faucets to allow air to vent from the heater and piping.
• Allow su cient time for the heater to completely  ll with water.
Check for leaks.
When  lling the water heater, open a hot water tap to release air in the tank and piping. The tank must be full of
water before the heater is turned on. Failure to ensure the water heater is full before turning it on could result
in damage to the water heater and other property damages. Such damages ARE NOT covered by water heater
warranty.
Part 4 - Electrical Connection
Tank must be full of water before the power is turned on. The heating element will be damaged if energized for
even a short time while tank is dry. Failures due to dry- ring ARE NOT covered by warranty.
The voltage requirement and dedicated wattage load for the heater is speci ed on the water heater rating label.
Consult your local power company to determine if your electrical service is adequate for the additional load of
the heater.
The 8 Model must be hard wired. The 8 Model needs to be wired with 12 GA wire to a 20 amp branch circuit. All
wiring must conform to local code and the National Electric Code, and should be done by a quali ed licensed
electrician or the local electric utility. See Figure 4, A and B.
Unscrew the junction box cover and remove it.
Insert 12 AWG wire through the conduit into the junction box and secure with conduit strain relief (not
supplied).
Connect the wires and screw on the cover of the junction box.
Make appropriate wiring connections to the water heater per the National Electric Code.
The unit must be grounded with supplied grounding cable inside the junction box.
Secure the junction box cover once wiring connections have been made.
When the 8 Model is not within sight of the electrical circuit breakers, a circuit breaker lockout or additional local
means of disconnection for all non-grounded conductors must be provided that is within sight of the appliance
(Ref. NEC 422.31).
Be sure to ground the water heater. Failure to do so could result in property damage, severe personal injury, or
death.
Figure 4 - 8 Model Wiring
13
EN
Part 5 - Installation Checklist
Water Heater Location Yes No
Close to area of heated water demand
Indoors and protected from freezing temperatures
Area free of  ammable vapors
Provisions made to protect area from water damage
Su cient room to service heater
Relief Valve Ye s N o
Temperature and Pressure Relief Valve properly installed and discharge line run to open drain
Discharge line protected from freezing
Wiring Ye s N o
Power supply voltage agrees with water heater rating plate
Branch circuit wire and fusing or circuit breaker of proper size
Electrical connections tight and unit properly grounded
Water Supply Ye s N o
Water heater completely  lled with water BEFORE operating the unit
Air purged from water heater and piping
Water connections tight and free of leaks
Table 3 - Installation Checklist
Part 6 - Operation
Tank must be full of water before the power is turned on. The heating element will be damaged if energized for
even a short time while tank is dry. Failures due to dry- ring ARE NOT covered by warranty.
A. Starting and Testing
For models not  tted with a switch:
Supply power to the water heater by plugging in the power cord (2.5 and 4 Models) or turning on the circuit
breaker (8 Model).
If the light does not turn on, turn the control knob in a clockwise direction.
The light will turn on until the water temperature has reached the thermostat temperature setting. The light
will come back on any time the water temperature inside the tank drops below the thermostat setting.
B. Thermostat Adjustment
The temperature of the hot water is adjusted by rotating the knob (M, see Figure 5) located on the front cover.
Turn the knob clockwise to increase temperature.
Turn the knob counterclockwise to decrease temperature.
Do not attempt to repair this water heater yourself. Call a quali ed service technician for assistance. Always
turn o the power supply to the heater prior to servicing or draining the heater. Failure to do so could result in
property damage, severe personal injury, or death.
Part 7 - Maintenance
For most of these maintenance operations, the water will have to be drained from the heater. For all of these
operations, the power cord should be disconnected (2.5 or 4 Models) or the power turned o at the circuit
breaker (8 Model), and the front cover removed.
14
EN
A. Removing the Cover
• Pry o the round knob cover plate (Figure
5, M) with a small  at head screwdriver.
• Pry o the screw covers (Figure 5, V) with
a small  at head screwdriver.
Remove the Phillips screws.
The cover (Figure 5, C) can now be
removed by pulling out its left hand edge.
When reassembling, work in the opposite
way, being careful to insert the tongue of
the cover into the slot.
B. Draining the Heater
If the heater has been installed with  exible
hoses:
• Shut o the power supply.
Turn the heater upside down over a sink
to drain the water out of it.
The water heater can also be emptied by:
Figure 5 - Water Heater Cover and Thermostat Detail
D. Inspecting the Anode Rod
The purpose of the anode rod (Figure 7, N)
is to protect the tank against corrosion. The
anode rod must be inspected once a year to
determine whether it requires replacement.
To access the anode rod, the heating element
must be removed. See Removing the Heating
Element above. Upon inspection, the anode
rod surface should appear smooth. If the rod
surface appears pitted, bumpy, rusty, or if the
rod is missing completely, then it must be
replaced.
Original anode rod sizes:
2.5 and 4 Models: length 6 1/2”, diameter
5/8”
C. Removing the Heating Element
• Shut o the power supply and drain the
water heater.
Remove the front cover plate. Disconnect
terminals X, Y, and T. See Figure 6.
Unscrew the four (4) heating element
retaining nuts (Figure 6, F).
Remove the element (Figure 6, G).
Figure 6 - Open Heater Cover Detail
Siphoning through the inlet side hose.
Keep a hot water faucet open while
siphoning.
If the heater has been installed with rigid
piping:
Siphon the water out through any lower
service valve on the inlet side.
Keep a hot water faucet open while
siphoning the water out.
Figure 7 - Heating Element and Anode Rod Detail
8 Model: length 8 1/4”, diameter 5/8”
Certain installations may require more frequent replacement of the anode rod:
• Recirculation applications;
Poor water quality;
Galvanic / Electrolytic corrosion;
• High ow applications
15
EN
Rusty water is usually an indication that the anode rod requires replacement. If rusty water is present, examine the
anode rod immediately and replace as needed. In the event of poor water quality, consult a local water treatment
professional for water treatment options. Always ensure the water heater is grounded. Damage resulting from
poor water quality or failure to replace the anode rod is not covered under the manufacturer’s warranty. For
additional questions, please contact Technical Support.
To change the anode rod:
1. Turn of the power supply and drain the heater (see Draining the Heater).
2. Remove the heating element (see previous section).
3. Unscrew the anode rod from threaded connection.
4. Remove and replace the anode rod (Figure 7, N).
5. Reinstall the heating element.
6. Re ll tank with water and purge air before restoring power.
E. Descaling the Heating Element
Scale deposits can a ect the heating capability of the element. Heavy scale can even cause damage to the
element. The element can be descaled either chemically or manually.
Soak the element in white vinegar or other food grade descaling solution approved for use in potable water
systems.
Once descaled, rinse well with a fresh water / baking soda solution.
The element can also be descaled manually:
After the element has dried, use a soft brush (non-metallic to prevent damaging th stainless steel sheath)
on the element.
Brush the dried minerals o .
Replace the anode rod if it is noticeably deteriorated or considerably smaller than described in Inspecting the
Anode Rod.
Reinstall the element after descaling. Ensure the element gasket is installed and that the element is rewired
correctly.
Ensure the tank has been re lled with water before restoring power to the water heater. Failures due to dry-
ring ARE NOT covered by warranty.
Table 4 - Troubleshooting
Part 8 - Troubleshooting
Problem Solution
Water
Does Not
Get Hot
Ensure the power supply is on and working
If light does not come on, check that the high limit reset button is pushed in. Follow steps to reset
the switch, this manual.
If the indicator light works properly but temperature does not get hot at the tap, test for a plumbing
crossover. Shut o the cold supply to the heater and open the hot water tap. There should be no
water  owing. Any continued  ow indicates a crossover which will a ect the temperature and
need to be corrected.
Call a quali ed service technician to test the resistance of the heating element (8-10 ohms). Heating
element should be replaced if readings are outside these values.
Light Not
On
If the light does not come on, but the water gets hot, check for faulty bulb.
Check that the high limit reset button is pushed in. Follow steps, this manual.
Brown
Water
Brown or rusty water indicates a “spent” anode rod and possible deterioration of the tank body.
Check anode rod. See instructions, this manual. Inspect the tank for leaks.
Water
Odor
Smelly water could be due to an unusual reaction between local water and the heater’s anode rod.
Check anode rod. See instructions, this manual. Failure to do so may result in damage to the tank
and leaks.
Leaks
Check water  ttings and T&P  tting on top of tank. Remove front cover and inspect heating
element gasket.
If tank is leaking, review warranty to see if heater is still within warranty period.
16
EN
Figure 8 - High Limit Switch Reset Detail
If draining of the water heater is necessary, open the T&P valve or a hot water tap to prevent vacuum buildup
in the tank and piping.
The risk of scald injury increases as you increase water temperature. A lower setting is more economical and
reduces the risk of scalding. Use a water tempering or mixing valve and extreme caution when using hot water
to avoid scald injury. Consult codes for conformance. Failure to follow the instructions in this warning statement
could result in serious personal injury or death from scalds.
Be sure to disconnect electrical power before performing service. Failure to do so could result in electrical shock,
property damage, serious personal injury, or death.
A. Resetting the High Limit Switch
Occasionally, the high temperature limit shut o device may trip
the reset. This occurs when water temperature exceeds 190
o
F. The
shut-o device may also trigger due to a power outage or electrical
storm.
To reach the thermostat:
Disconnect the power cord (or shut o the circuit breaker - 8
Model) and remove the front cover.
Firmly press the reset button with the tip of a ball point pen or
similar object. See Figure 8, B.
A click indicates the reset was tripped.
Reconnect the power.
Check the operation of the thermostat. See the following section.
Call a technician if the high limit needs to be reset frequently.
B. Checking Thermostat Operation
To check thermostat operation:
Turn the temperature dial from high to low. If the red light does not turn o on the low setting, turn o the
power supply and call a quali ed service technician to replace the thermostat.
If the red light does go o , the thermostat is working properly.
Turn the dial to the desired setting. NOTE: A lower setting is more economical and reduces the risk of
scalding.
Replace the cover plate.
NOTE: After adjusting the water temperature at the thermostat, allow the water heater enough time to heat
the water to temperature. After the water heater has stopped heating, use a thermometer to measure the water
temperature at a hot water outlet in the structure.
C. Changing the Heating Element
• Turn o the power supply and drain the water heater (see procedure, this manual).
Remove heating element (see procedure, this manual).
Install new element with gasket, making sure the gasket and element are positioned correctly. Tighten the
retaining nuts and wire connections.
Ensure the thermostat temperature sensor is inserted into the well located on the element assembly and
secured with a black rubber grommet.
• Re ll the tank with water before restoring power.
D. Changing the Thermostat
• Turn o the power supply.
Disconnect the two (2) wire connectors on the thermostat.
Loosen the two (2) brass screws on the right side of the thermostat and pull the wires out.
Unscrew and remove the two (2) Phillips screws holding the thermostat onto the tank.
Install the new thermostat and re-attach the wiring and screws.
Ensure the thermostat temperature sensor is inserted into the well located on the element assembly and
secured with black rubber grommet.
17
EN
Part 9 - Replacement Parts
Figure 9 - Replacement Parts
Table 5 - Replacement Part Numbers
Item # Description
Part #
Item # Description
Part #
Model Model
2.5 4 8 2.5 4 8
1
Screw M6x12
( ange xing)
65114656 65114656 65114656 10
Wall Hanging
Bracket
570341 570341 570341
2
Screw M6x12
(element  xing)
993000 993000 993000 11 Screw cover 65118185 65118185 65118185
3 Flange 65115359 65115359 65115359 12 Knob 65118186 65118186 65118186
4
Faston
protection
65118180 65118180 65118180 13 Plastic cover 65118187 65118187 65118188
5 Heating element 65118181 65118182 65118182 14
Plastic
protection
65118189 65118189 65118190
6
Heating
element gasket
65116115 65116115 65116115 15
Thermostat
lever
570029 570029 570029
7
Magnesium
anode
65103768-01 65103768-01 65103768-01 16 Cable clip 65150321 65150321 65150321
8 Power cable 65118183 65118183 65118184 17
TBSB Wired
Thermostat
65118191 65118192 65118192
9 T&P Valve 3/4" 65150323 65150323 65150323 18
Support for TBSB
Thermostat
65115134 65115134 -----
18
EN
Mini Tank Electric Water Heater Limited Warranty
The manufacturer warrants each small capacity point of use
electric water heater and its components to be free from defects
in materials and workmanship according to the following terms,
conditions, and time periods. UNLESS OTHERWISE NOTED THESE
WARRANTIES COMMENCE ON THE DATE OF INSTALLATION. This
limited warranty is only available to the original consumer
purchaser (hereinafter “Owner”) of the water heater, and is non-
transferable.
WARRANTY PERIODS
Mini Tank Electric
Water Heater
Parts Tank
Two (2) Years Six (6) Years
COVERAGE
A. During the  rst two (2) years after the original date of
installation the manufacturer warrants that it will repair
or replace, at its option, any defective or malfunctioning
component of the water heater. Replacement components will
be warranted for ninety (90) days.
B. Should a defect or malfunction result in a leakage of water
from the water heater within the  rst six (6) years after the
original date of installation due to defective material or
workmanship, malfunction, or failure to comply with the
above warranty, with such defect or malfunction having been
veri ed by an authorized representative of the manufacturer,
the manufacturer will repair or replace, at its option, the
defective or malfunctioning water heater. Replacements will
be of the nearest comparable model available at the time of
replacement. The replacement water heater will be warranted
for the unexpired portion of the applicable warranty period of
the original water heater.
C. In the event of a leakage of water of a replacement water
heater due to defective material or workmanship, malfunction,
or failure to comply with the above warranty, the manufacturer
reserves the right to refund to the Owner the published
wholesale price available at the date of manufacture of the
original water heater.
D. If government regulations, industry certi cation, or
similar standards require the replacement water heater or
component(s) to have features not found in the defective
water heater or component(s), the Owner will be charged the
di erence in price represented by those required features. If the
Owner pays the price di erence for those required features and/
or to upgrade the size and/or other features available on a new
replacement water heater or component(s), the Owner will also
receive a complete new limited warranty for that replacement
water heater or component(s).
E. If at the time of a request for service the Owner cannot provide
a copy of the original sales receipt or the warranty registration,
the warranty period for the water heater shall then be deemed
to have commenced on the date of manufacture of the water
heater and NOT the date of installation of the water heater, and
be covered by the unexpired portion of the warranty detailed
above.
F. This warranty extends only to water heaters utilized in
water heating applications that have been properly installed
by quali ed professionals based upon the manufacturer’s
installation instructions.
G. It is expressly agreed between the manufacturer and the
Owner that repair, replacement, or refund are the exclusive
remedies of the Owner.
OWNER RESPONSIBILITIES
The Owner or Quali ed Installer / Service Technician must:
1. Have a relief valve bearing the listing marks of the American
Society of Mechanical Engineers (ASME) installed with the water
heater assembly in accordance with federal, state, and local
codes.
2. Have a vacuum relief valve certi ed to ANSI Z21.22 - Relief
Valves for Hot Water Supply Systems - installed with the water
heater assembly in accordance with federal, state, and local
codes and in installations prone to vacuum related damages.
3. Maintain the water heater in accordance with the maintenance
procedure listed in the manufacturer’s provided instructions.
Preventive maintenance can help avoid any unnecessary
breakdown of the water heater and keep it running at optimum
e ciency.
4. Maintain all related system components in good operating
condition.
5. Use the water heater in an open system, or in a closed system
with a properly sized and installed thermal expansion tank.
6. Use the water heater at water pressures not exceeding the
working pressure shown on the rating plate.
7. Keep the water heater free of damaging scale deposits.
8. Make provisions so if the water heater or any component or
connection thereto should leak, the resulting  ow of water will
not cause damage to the area in which it is installed.
WARRANTY EXCLUSIONS
This limited warranty will not cover:
1. Any water heater purchased from an unauthorized dealer.
2. Any water heater not installed by a quali ed heating installer
/ service technician, or installations that do not conform to ANSI,
CSA, and/or UL standards, as well as any applicable national or
local building codes.
3. Service trips to teach the Owner how to install, use, maintain,
or to bring the water heater installation into compliance with
local building codes and regulations.
4. The workmanship of any installer. The manufacturer disclaims
and does not assume any liability of any nature caused by
improper installation, repair, or maintenance.
5. Electricity or fuel costs, or increased or unrealized savings for
same, for any reason whatsoever.
6. Any water damage arising, directly or indirectly, from any
defect in the water heater or component part(s) or from its use.
7. Any incidental, consequential, special, or contingent damages
or expenses arising, directly or indirectly, from any defect in the
water heater or the use of the water heater.
8. Failure to locate the water heater in an area where leakage
of the tank or water line connections and the relief valve will
not result in damage to the area adjacent to the water heater
or lower  oors of the structure, as well as failure to install the
water heater in or with a properly sized drain pan routed to an
approved drainage location.
9. Any failed components of the system not manufactured by
the manufacturer as part of the water heater.
10. Water heaters repaired or altered without the prior written
approval of the manufacturer.
11. Damages, malfunctions, or failures resulting from improper
installation, or failure to install the water heater in accordance
with applicable building codes/ordinances or good plumbing
and electrical trade practices; or failure to operate and maintain
the water heater in accordance with the manufacturer’s
provided instructions.
12. Damages, malfunctions, or failures resulting from failure
to operate the water heater at pressures not exceeding the
working pressure shown on the rating label.
13. Failure to operate the water heater in an open system, or
in a closed system with a properly sized and installed thermal
19
EN
expansion tank.
14. Failure or performance problems caused by improper sizing
of the water heater, expansion device, piping, electric service
voltage, wiring or fusing.
15. Damages, malfunctions, or failures caused by lack of anode
rod maintenance.
16. Damages, malfunctions, or failures resulting from vacuum
conditions.
17. Damages, malfunctions, or failures caused by operating
the water heater with modi ed, altered, or unapproved
components, or any component / attachment not supplied by
the manufacturer.
18. Damages, malfunctions, or failures caused by abuse,
accident,  re,  ood, freeze, lightning, electrochemical reaction,
acts of God and the like.
19. Tank failures (leaks) caused by operating the water heater in
a corrosive or contaminated atmosphere.
20. Damages, malfunctions, or failures caused by operating the
water heater with an empty or partially empty tank (“dry  ring”),
or failures caused by operating the water heater when it is not
supplied with potable water, free to circulate at all times.
21. Failure of the heater due to the accumulation of solid
materials or lime deposits.
22. Any damage or failure resulting from improper water
chemistry, or heating anything other than potable water.
23. Production of noise, taste, odors, discoloration, or rusty
water.
24. Water heaters replaced for cosmetic reasons.
25. Components of the water heater that are not defective,
but must be replaced during the warranty period as a result of
reasonable wear and tear.
26. Components of the water heater that are subject
to warranties, if any, given by their manufacturers; the
manufacturer does not adopt these warranties.
27. Damages, malfunctions, or failures resulting from the use of
any attachment(s) not supplied by the manufacturer.
28. Water heaters installed outside the  fty states (and the
District of Columbia) of the United States of America and
Canada.
29. Water heaters moved from the original installation location.
30. Water heaters that have had their rating labels removed.
PROCEDURES FOR WARRANTY SERVICE REQUESTS
Any claim for warranty assistance must be made promptly.
Determine if the water heater is in-warranty” (that is, within the
applicable warranty period) by reviewing a copy of the original
sales receipt or warranty registration. The Owner must present
a copy of the original sales receipt or warranty registration for a
warranty service request.
If the water heater is “in-warranty”, contact the retailer from
whom the water heater was purchased (or the installer) for
assistance. Be prepared to provide the retailer or installer with a
copy of the original receipt, complete model and serial numbers,
and the date of installation of the water heater, in addition to
explanation of the water heater problem.
Warranty coverage is subject to validation of “in-warranty”
coverage by the manufacturer claims department personnel.
All alleged defective or malfunctioning components must be
returned to the manufacturer via the local distribution channels
where original purchase was made. NOTE: Any components or
heaters returned to the manufacturer for warranty analysis
will become the property of the manufacturer and will not
be returned, even if credit is denied. If all warranty conditions
are satis ed, the manufacturer will provide replacement
components to the retailer.
For questions about the coverage of this warranty, please
contact the manufacturer at the following address or phone
number: HTP (an Ariston Thermo Group Company), 272
Duchaine Blvd, New Bedford, MA, 02745
Attention: Warranty Service Department, 1 (774) 271 3108
SERVICE, LABOR, AND SHIPPING COSTS
Except when speci cally prohibited by the applicable state law,
the Owner, and not the Manufacturer, shall be liable for and
shall pay for all charges for labor or other expenses incurred
in the removal, repair, or replacement of the appliance or any
component part(s) claimed to be defective or any expense
incurred to remedy any defect in the product. Such charges
include, but are not necessarily limited to:
1. All freight, shipping, handling, and delivery costs of
forwarding a new appliance or replacement part(s) to the
owner.
2. All costs necessary or incidental in removing the defective
appliance or component part(s) and installing a new appliance
or replacement part(s).
3. All administrative fees incurred by the Owner, as well as
material required to complete, and/or permits required for,
installation of a new appliance or replacement part(s), and
4. All costs necessary or incidental in returning the defective
water heater or component part(s) to a location designated by
the manufacturer.
LIMITATIONS OF YOUR WARRANTY AND REMEDIES
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND ARE GIVEN
AND ACCEPTED TO THE FURTHEST EXTENT UNDER APPLICABLE
LAW IN LIEU OF ANY AND ALL OTHER WARRANTIES, EXPRESS
OR IMPLIED, INCLUDING WITHOUT LIMITATION THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE AND ANY OBLIGATION, LIABILITY,
RIGHT, CLAIM OR REMEDY IN CONTRACT OR TORT, WHETHER
OR NOT ARISING FROM THE MANUFACTURER’s NEGLIGENCE,
ACTUAL OR IMPUTED. THE REMEDIES OF THE OWNER SHALL
BE LIMITED TO THOSE PROVIDED HEREIN TO THE EXCLUSION
OF ANY OTHER REMEDIES INCLUDING WITHOUT LIMITATION,
INCIDENTAL OR CONSEQUENTIAL DAMAGES, SAID INCIDENTAL
AND CONSEQUENTIAL DAMAGES INCLUDING, BUT NOT LIMITED
TO, PROPERTY DAMAGE, LOST PROFIT OR DAMAGES ALLEGED TO
HAVE BEEN CAUSED BY ANY FAILURE OF THE MANUFACTURER
TO MEET ANY OBLIGATION UNDER THIS AGREEMENT INCLUDING
THE OBLIGATION TO REPAIR AND REPLACE SET FORTH ABOVE.
NO AGREEMENT VARYING OR EXTENDING THE FOREGOING
WARRANTIES, REMEDIES OR THIS LIMITATION WILL BE BINDING
UPON THE MANUFACTURER. UNLESS IN WRITING AND SIGNED
BY A DULY AUTHORIZED OFFICER OF THE MANUFACTURER. THE
WARRANTIES STATED HEREIN ARE NOT TRANSFERABLE AND
SHALL BE FOR THE BENEFIT OF THE OWNER ONLY.
NO OTHER WARRANTIES
This warranty gives the Owner speci c legal rights. The Owner may
also have other rights that vary from state to state. Some states do
not allow the exclusion or limitation of incidental or consequential
damages so this limitation or exclusion may not apply to the Owner.
These are the only written warranties applicable to the water heater
manufactured and sold by the manufacturer. The manufacturer
neither assumes nor authorizes anyone to assume for it any other
obligation or liability in connection with said water heaters.
The manufacturer reserves the right to change speci cations or
discontinue models without notice.
20
EN
Customer Installation Record Form
The following form should be completed by the quali ed installer / service technician for you to keep as a
record of the installation in case of a warranty claim. After reading the important notes at the bottom of the
page, please also sign this document.
Customer’s Name
Date of Installation
Installation Address
Product Model / Serial
Number(s)
Comments
Installers Code / Name
Installers Phone Number
Signed by Installer
Signed by Customer
Installation Notes
IMPORTANT
Customer: Please only sign after the quali ed installer / service technician has fully reviewed the installation,
safety, proper operation, and maintenance of the system. If the system has any problems please call the quali ed
installer / service technician. If you are unable to make contact, please call your sales representative.
Distributor / Dealer: Please insert contact details.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Ariston ANDRIS RS 8U 1.4KW Manuel utilisateur

Catégorie
Chauffe-eau
Taper
Manuel utilisateur
Ce manuel convient également à