Savant QP1R30240 Guide d'installation

Taper
Guide d'installation
Savant Product Regulatory Statement | 009-1950-02
220127 | © 2022 Savant Systems, Inc.
45 Perseverance Way, Hyannis, MA 02601
Savant.com | 508.683.2500
1 of 2
Important Safety Information - Read First!
Before installing, configuring, or operating any equipment, all relevant technical documentation must be read,
understood, and followed. Savant technical documentation may contain important product-specific installation,
mounting, and safety instructions, and can be accessed through the Savant Store.
Scan the QR code or visit the URL below, enter the relevant product name or SKU in the Search Savant prompt, and
select the product purchased to find documents, specifications and more.
https://store.savant.com/DefaultStore/ccrz__HomePage
Product Information and Regulatory Statement
Safety Statements
All safety instructions below must be read, understood, and
carefully followed under all applicable circumstances when
working with any Savant equipment.
1. Follow all input power ratings marked on product near power
input!
2. If fuse replacement is required, replacement fuse should match
fuse rating marked on the product.
3. Do not use equipment near water.
4. Clean only with dry cloth.
5. Do not block any ventilation openings or install near any heat
sources such as heat registers, stoves, radiators, amplifiers,
etc.
6. Refer all servicing to qualified service personnel. Servicing is
required when any part of the apparatus has been damaged in
any way, or fails to operate normally for any reason.
7. Use only attachments/accessories specified by the
manufacturer, following all relevant safety precautions for any
such attachments/accessories.
8. For applicable equipment, use the included power cord with
the grounding prong intact to insure proper grounding of the
device.
9. If the provided plug does not fit the desired outlet, contact a
licensed electrician to replace the obsolete outlet.
10. Protect any power cord from being walked on, pinched,
strained, or otherwise potentially damaged, especially at the
outlet or device connections.
11. Disconnect any outlet powered apparatus from its power
source during lightning storms or when unused for long
periods of time.
12. To completely disconnect equipment from AC mains power,
disconnect the power supply cord plug from the AC
receptacle on the device.
13. For any hardwired or fixed in-wall apparatus, carefully follow
all wiring diagrams and instructions. All electrical wiring
and servicing should be performed by a properly licensed
electrician.
Déclarations de Sécurité
Toutes les instructions de sécurité ci-dessous doivent être lues,
comprises et soigneusement suivies dans toutes les circonstances
applicables lorsque vous travaillez avec un équipement Savant.
1. Suivez toutes les puissances nominales indiquées sur le
produit près de la puissance absorbée!
2. Si le remplacement du fusible est nécessaire, le fusible de
remplacement doit correspondre à la valeur nominale du
fusible indiquée sur le produit.
3. N’utilisez pas d’équipement près de l’eau.
4. Nettoyer uniquement avec un chion sec.
5. Ne bloquez pas les ouvertures de ventilation et n’installez pas
à proximité de sources de chaleur telles que les registres de
chaleur, les cuisinières, les radiateurs, les amplificateurs, etc.
6. Confiez toutes les réparations à un technicien qualifié.
Un entretien est requis lorsqu’une partie de l’appareil a
été endommagée de quelque manière que ce soit ou ne
fonctionne pas normalement pour une raison quelconque.
7. Utilisez uniquement les attachements / accessoires spécifiés
par le fabricant, en suivant toutes les précautions de sécurité
applicables à ces attachements / accessoires.
8. Pour l’équipement applicable, utilisez le cordon d’alimentation
inclus avec la broche de mise à la terre intacte pour assurer
une mise à la terre correcte de l’appareil.
9. Si la fiche fournie ne correspond pas à la prise souhaitée,
contactez un électricien agréé pour remplacer la prise
obsolète.
10. Protégez tout cordon d’alimentation contre les piétinements,
les pincements, les tensions ou autres dommages potentiels,
en particulier au niveau de la prise ou des connexions de
l’appareil.
11. Débranchez tout appareil alimenté par une prise de courant de
sa source d’alimentation pendant les orages ou lorsqu’il n’est
pas utilisé pendant de longues périodes.
12. Pour déconnecter complètement l’équipement du secteur,
débranchez la fiche du cordon d’alimentation de la prise
secteur de l’appareil.
13. Pour tout appareil encastré ou câblé, suivez attentivement
tous les schémas de câblage et les instructions. Tout le
câblage électrique et l’entretien doivent être eectués par un
électricien dûment agréé.
IMPORTANT NOTES:
For product mounting, installation, safety instructions, technical specifications, and more, refer to the product Quick
Reference Guide, available via the link or QR code noted above.
For regulatory and compliance information, see reverse of this sheet and/or product packaging.
Savant Product Regulatory Statement | 009-1950-02
220127 | © 2022 Savant Systems, Inc.
45 Perseverance Way, Hyannis, MA 02601
Savant.com | 508.683.2500
2 of 2
FCC Regulations
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for CLASS B digital devices, pursuant to Part 15 of FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio
or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try correcting the
interference with one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect this equipment to an outlet on a circuit dierent from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
FCC Caution
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to
operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Radiation Exposure Statement - Wireless and Handheld Devices Only
This equipment complies with FCC and IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be
installed and operated with minimum distance of 20 cm between the radiator and your body.
FCC and IC Identifier - Devices with Integrated Screen or User Interface Only
This device electronically displays the FCC declaration of conformity logo as well as the FCC and IC identifier. This information can be
found on the device by accessing:
(Service menu) > About (A propos de)
IC Statement
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, including interference that may cause undesired operation of the device.
This Class B digital apparatus complies with Canadian ICES-003/NMB-003.
This device complies with RSS-247 of Industry Canada. Operation is subject to the condition that this device does not cause harmful
interference.
This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter, except tested
built-in radios. The Country Code Selection feature is disabled for products marketed in the US/Canada.
Déclaration IC
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. Lexploitation est
autorisée aux deux conditions suivantes:
1. L’appareil ne doit pas produire de brouillage, et
2. Cet appareil accepter toute interférence, y compris les interférences pouvant provoquer fonctionnement indésirable d’appareil.
Déclaration d’exposition aux radiations
Cet équipement est conforme aux limites d’exposition aux radiations de la FCC définies pour un environnement non contrôlé. Cet
équipement doit être installé et utilisé avec une distance minimale de 20 cm entre le radiateur et votre corps.
Identificateur de la FCC et d’Lc
Ce périphérique par voie électronique ache le logo de déclaration de conformité FCC ainsi que l’identificateur de la FCC et d’IC. Cette
information peut être trouvée sur le terminal en accédant à:
(Menu de service) > About (A propos de)
Single 30 Amp Relay Companion Module - QRG | 009-2112-00 1 of 4 45 Perseverance Way, Hyannis MA 02601
Copyright ©2022 Savant Systems, Inc | 220113 Savant.com | 508.683.2500
DO NOT
PRESS ON
SCREEN
REMOVE AFTER
INSTALLATION
PAIR
CIRCUIT POWER
ON
AUTO
A
B
C
F
G
E
240V 30A 2-POLE RELAY
GPM-QP1R30240
MODULE INPUT:
INDOOR USE ONLY
#10-8 AWG Cu ONLY
HOME AUTOMATION EQUIP.
IC ID: 10798A-QP1R30240
FCC ID: PUU-QP1R30240
E523609
YYWW
120VAC 60Hz
240VAC 60Hz
240VAC 30A/2HP MAX
LOAD INPUT:
LOAD OUTPUT:
INPUT
INPUT
OUTPUT
OUTPUT
L2 L2
L1 L1
D
A
Multi-Page LCD screen that can display the following:
Power draw at the output.
Firmware, Mac Address, and Regulatory Info.
UID of the Host the module is communicating with.
Real-time Bluetooth status connectivity icon.
BManual Load Switch - Toggle to the ON position to switch the
load on. Toggle to AUTO for normal operation.
C
PAIR Button - The PAIR button is a multi-use button. The
duration that the button is pressed and held determines the
function that gets initiated:
Press and Release - Cycles through the various screens
available on the LCD (POWER > ENERGY > INFO 1 > INFO 2).
Press and hold - Press and hold for 2 seconds to put module
into pairing mode. Press and hold for 5 seconds to reset.
DInput Power Connections - Connect outputs from two
breakers to inputs L1 and L2 on the module. See the Wiring
section below.
EOutput Power Connections - Connect a 240V AC load across
outputs L1 and L2. See the Wiring section below.
F120V AC Connection - Plugs into the 120V AC bus bar in the
breaker panel. The voltage on this connection powers the
module.
G
Neutral - The model number of the module determines the
type of neutral connection on the module:
Plug-On Neutral - Positioned on the bottom of the module
is a neutral clip that plugs directly onto the neutral bar.
Pigtail Neutral - A neutral wire protrudes from the
module’s rear and gets wired to the neutral bar in the
breaker panel.
Supported Software
Savant OS da Vinci 10.2
Electrical and Safety Characteristics
Screw Tighten Torque 3.0 Nm
Wire Type Copper (Cu) only
Pollution Degree 2
Purpose of Control Operating Control, Smart Relay Control
Module or the equivalent
Software Class A
Impulse Voltage 2500V
Supported Load Types
Standard Configuration Relay On/O type loads (home automation)
Standards
Wireless Bluetooth Low Energy (BLE)
2.4 GHz radio frequency
Regulatory
Safety and Emissions
FCC Part 15 UL ICES 003
Contains FCC ID: PUU-QP1R30240
Contains IC: 10798A-QP1R30240
RoHS Compliant
Recommended Load Center Types
All QO™ compatible modules fit into ¾ inch load centers.
Power
Input Power
(powers the module) 120V AC (+/- 10%) @ 60 Hz, 0.1A (max)
Input Power
(from feeder breaker) 120V AC per input - 30A (max)
Load Power 7200VA
(240VAC 30A resistive load / 2HP max)
Features of Automatic
Action Type 1.B action
Dimensions and Weights (net)
Height Length Depth Weight
Module
(QO)
1.45 in.
(3.68 cm)
4.97 in.
(12.63 cm)
2.60 in.
(6.61 cm)
.5 lbs
(.23 kg)
Shipping 1.71 in.
(4.34 cm)
7.50 in.
(19.05 cm)
4.30 in.
(10.92 cm)
1.0 lbs.
(.45 kg)
Environmental
Temperature 32° to 104° F (0° to 40° C)
Humidity 5% to 85% Relative Humidity (non-condensing)
Location Indoor Use Only
Features
Control capability for loads up to 7200 VA (volt-ampere).
All QO™ relay modules are compatible with Schneider Electric/
Square D™ QO™ load centers.
Dynamic management of loads.
Built-in energy monitoring; +/- .5% revenue grade accuracy / 1 sec
sample time.
Communicates over the air using Bluetooth Low Energy (BLE)
technology.
Manual load switch on the front panel can toggle power to the
output On and O.
Color LCD display for easy identification and load status.
Single 30 Amp Relay Companion Module (2-Pole, 240V AC)
Quick Reference and Installation Guide
Specifications
Box Contents Descriptions
(1) 240VAC (2 Pole) Relay Companion Module
GPM-QP1R30240-21 QO™ w/Plug-on Neutral
GPM-Q1R30240-21 QO™ w/Pigtail Neutral
(1) Product Information and Regulatory Insert (009-1950)
(1) Quick Reference and Installation Guide (this document)
Construction of Control
Open Type Independently mounted for flush mounting
Single 30 Amp Relay Companion Module - QRG | 009-2112-00 2 of 4 45 Perseverance Way, Hyannis MA 02601
Copyright ©2022 Savant Systems, Inc | 220113 Savant.com | 508.683.2500
ELECTRIC SHOCK! The 120/240V AC, 60 Hz source poses an
electrical shock hazard that has the potential to cause serious
injury to installers and end users.
CAUTION! Risk of Electric Shock - More than one disconnect
switch may be required to de-energize the device before
servicing.
IMPORTANT! A licensed electrician is required to install any of
Savant’s Relay Companion Modules.
Installation into Breaker Panel
Important Information
The breaker(s) feeding this module should not be larger than 30 amps.
This relay module can handle loads up to 30 amps.
To determine the number of breaker panel spaces needed, add the number of spaces required for the circuit breakers with the spaces needed
for the module.
Each 2-pole circuit breaker requires two spaces.
Each Companion Module requires two spaces.
Savant recommends not connecting any mission critical loads such as medical devices to this relay module.
Wiring with Plug-on Neutral Wiring with Pigtail Neutral
240V AC
Plug-on
neutral bar
Neutral Bar
Breaker Panel
Companion Module
with Plug-on Neutral
NOTE: The companion module
connects to just one phase.
The 2-pole breaker connects
to both phases.
Phase A
Phase B
STANDARD
BREAKER
STANDARD
BREAKER
2-POLE BREAKER
INPUT OUTPUT
OUTPUT
L2
L1
A
L2
L1
INPUT
CIRCUIT POWER
ON
AUTO
PAIR
240VAC 2-POLE
RELAY
Load 120V AC
30
IMPORTANT! When making connections, observe all general electrical best practices which includes the local wire sizing guideline codes.
See the Branch Circuit Minimum Size Conductors table above.
1. Remove power from the breaker panel by switching o the panel’s main breaker.
2. Position and install a 2-pole breaker into any two slots in the breaker panel. Press firmly until the breaker is fully seated onto the
appropriate bus bars.
3. Position and install the Companion Relay Module into any two empty slots in the breaker panel. Press firmly until fully seated onto
the appropriate bus bar. This module is typically installed alongside the 2-pole breaker installed in step 2.
4. Use the diagrams below and make the appropriate connections. The diagram on the left is for the modules that contain a plug-on
neutral clip. The diagram on the right is for modules that include a neutral wire.
HELPFUL! This relay module fills two slots in the breaker panel but connects to only one phase (120V AC). See diagram below.
Branch Circuit Minimum Size of Conductors
(General circuit wiring, Copper Conductors)
15A 20A 30A 40A 50A 60A
#14 AWG #12 AWG #10 AWG #8 AWG #6 AWG #4 AWG
NOTE: This wiring requirement was based on the National Electric Code
(NEC) (ANSI/NFPA70), Canadian Electric Code, Part 1 (CEC), and local
codes Minimum Size of Conductors.
240V AC
120V AC
Neutral Bar
Breaker Panel
Companion Module
with Pigtail Wire for
the Neutral
NOTE: The companion module
connects to just one phase.
The 2-pole breaker connects
to both phases.
Phase A
Phase B
STANDARD
BREAKER
STANDARD
BREAKER
2-POLE BREAKER
INPUT OUTPUT
OUTPUT
L2
L1
A
L2
L1
INPUT
CIRCUIT POWER
ON
AUTO
PAIR
240VAC 2-POLE
RELAY
30
Load
Single 30 Amp Relay Companion Module - QRG | 009-2112-00 3 of 4 45 Perseverance Way, Hyannis MA 02601
Copyright ©2022 Savant Systems, Inc | 220113 Savant.com | 508.683.2500
Circuit Test Instructions
Use the instructions below to test the relay modules. The setup requires:
30 Amp Relay Companion Module.
Load with maximum amperage of 30A.
Standard 2-pole, 30 amp circuit breaker.
Breaker test panel. The type of module determines the type of breaker panel (plug-on neutral or not).
120/240V AC source
120V AC
120V AC
240V AC
Neutral Bar
Plug-on Neutral Bus Bar
240V AC
Load
INPUT OUTPUT
OUTPUT
L1
INPUT
CIRCUIT POWER
ON
AUTO
PAIR
240V 2-POLE RELAY
L1
L2 L2
standard
2-pole breaker
30 30
3
2
7
1
The companion module connects
to only one phase. The 2-Pole
breaker connects to both phases
5
4
8
1. Plug the 240V AC 2-Pole Companion Module and 30 amp 2-pole feeder breaker into the circuit breaker test panel.
2. Connect the output from one of the breakers on the 2-pole
breaker to the L1 input on the module.
3. Connect the output from the remaining side of the 2-pole
breaker to the L2 input on the module.
4. Connect one side of a load to the L1 output on the module.
5. Connect the remaining side of the load to the L2 output on the
module.
6. Apply power to the breaker panel (not shown in diagram)
7. Toggle the 30 amp 2-pole breaker to On.
8. To test, toggle the CIRCUIT POWER switch to the ON position
and observe the load switches On. Toggle the CIRCUIT POWER
switches to AUTO and verify the load switches O.
IMPORTANT!
The 2-pole breaker connects across both phases in the breaker panel. The module, however, attaches to only one phase. This is shown in
the image below.
The GPM-QP1R30240-21 and GPM-Q1R30240-21 modules can accept up to a #10 AWG wire. See the Branch Circuit Minimum Size of
Conductors table on the previous page.
Additional Documentation
Further information is available in the documents listed below and can be accessed via the Savant Customer Community.
Panel Bridge Controller with PoE (PBC-P1000) QRG
Savant Panelized Lighting Deployment Guide.
Single 30 Amp Relay Companion Module - QRG | 009-2112-00 4 of 4 45 Perseverance Way, Hyannis MA 02601
Copyright ©2022 Savant Systems, Inc | 220113 Savant.com | 508.683.2500
Notes
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Savant QP1R30240 Guide d'installation

Taper
Guide d'installation

dans d''autres langues