Avent ISIS iQ DUO SCF294/21 Manuel utilisateur

Catégorie
Tire-lait
Taper
Manuel utilisateur

Ce manuel convient également à

83 0081 0499 #1 (01/06)
AVENT
®
, Suffolk, CO10 7QS, England
Call TOLL FREE: 1.800.54.AVENT
SANS FRAIS : 1.800.54.AVENT
LÍNEA GRATUITA: 1.800.54.AVENT
LIMITED GUARANTEE
This product is a personal care item and therefore cannot be returned once opened. In the event
of a manufacturing defect, we will gladly provide replacement parts or a possible exchange. If you
experience any problems with this product, please DO NOT return it to the retailer. Call our Customer
Service toll free at 1.800.54.AVENT, where our representatives will be happy to assist you.
NOTE:For our guarantee to be valid the claim must not be a result of accident, misuse,improper care,
neglect or normal wear and tear.
GARANTIE LIMITÉE
Pour des raisons d'hygiène, ce produit ne peut être retourné une fois l'emballage ouvert.
Si le produit s'avère défectueux, nous remplacerons les pièces défectueuses ou nous échangerons
le tire-lait le cas échéant. Si vous éprouvez des difficultés avec ce produit, NE LE RETOURNEZ PAS
au détaillant.Veuillez plutôt communiquer sans frais avec notre service à la clientèle au
1.800.54.AVENT. où nos représentants se feront un plaisir de vous aider.
NOTE : La présente garantie ne s'applique pas à tout dommage causé par accident,abus,mauvaise
utilisation, usage impropre, négligence ou usure normale.
GARANTÍA LIMITADA
Este es un producto de cuidado personal y por eso no se lo puede devolver a la tienda una vez
abierto. En el caso de un defecto del fabricante, con gusto proporcionaremos piezas de repuesto
o un posible intercambio. Si experimenta cualquier problema con esto producto, NO lo
devuelva a la tienda. Llame gratuitamente a nuestro departamento de Atención al Cliente
al 1.800.54.AVENT, donde con gusto nuestros representantes le atenderán.
NOTE: Para que nuestra garantía sea válida, la reclamación no puede ser el resultado de un accidente,
uso incorrecto,mantenimiento inapropiado,negligencia o desgaste natural.
Exclusively Imported and Distributed by AVENT America, Inc.
475 Supreme Drive, Bensenville, IL 60106, USA
www.aventamerica.com
TM
ISIS DUO
Guide to Your Pump
Mode d’emploi de votre tire-lait
Guía para su Extractor
1
First (Control) Pump Second Pump
Pump Motor
1 x Control handle
2 x Silicone diaphragms
2 x White valves
2 x Pump bodies
4 x Reusable bases
(2 x 4 oz/125 ml and 2 x 9 oz/260 ml)
2 x Stands (same as )
2 x Let-down Massage Cushions
2 x Funnel covers (same as )
1 x Control cable
2 x Transparent tubes
1 x Twin tubing
1 x Double pumping connector
1 x Pump motor
1 x Electric adaptor
1 x Wall plug cord
2 x Dome caps
2 x Newborn nipples
2 x Screw rings
2 x Travel covers
2 x Sealing discs
a
b
c
d
e
f
f
g
h
i
j
k
l
m
n
o
p
q
r
s
t
a
b
c
d
e
f
b
c
d
e
f
g
h
g
h
i
j
j
k
l
m
n
o
p
q
r
s
t
h
2
One-Touch
Memory Control
Control Handle
Pump Motor
Light
Control Cable Socket
Power Socket
Twin Tubing Port
Control Cable Socket
Tubing Port
NEVER SANITIZE OR IMMERSE IN WATER
NEVER SANITIZE OR IMMERSE IN WATER
On/Off Switch
Control Handle
Need Help? Call us at 1.800.54.AVENT or visit www.aventamerica.com
When assembled parts b – g make up an assembled pump body.When the Control Handle
(a) is added to this assembled pump body, it becomes the First (Control) Pump.When the Double
Pumping Connector (l) is added to this assembled pump body, it becomes the Second Pump.
All you need to assemble and use ISIS iQ is shown here.If any of the parts are missing,or if you have
any questions,please call customer support at 1.800.54.AVENT or visit www.aventamerica.com
ISIS iQ DUO
Pump Parts Guide ISIS iQ DUO
Pump Parts Guide – Detailed
Need Help? Call us at 1.800.54.AVENT or visit www.aventamerica.com
Manual Pumping with ISIS
ISIS Manual Pump Parts Guide 15
Cleaning the ISIS Manual Pump 15
Assembling the ISIS Manual Pump 16
Using the ISIS Manual Pump 17
Whats Inside:
Electric Pumping
(Single and Double)
ISIS iQ DUO Pump Parts Guide 1-2
Warnings and Cautions 3
Disassembling ISIS iQ DUO 5
Cleaning and Sanitizing ISIS iQ DUO 6
Preparing to Pump 7-8
Assembling Pump Bodies
of ISIS iQ DUO 9-10
Connecting the Electronics
of ISIS iQ DUO 11-12
Pumping with ISIS iQ DUO 13-14
Keeping Parts Clean and
Compact for Travel 18
Storing Your Expressed Breast Milk 19-20
Troubleshooting Guide 21
Technical Specifications 22
4
Please take a few minutes to read
through this entire instruction leaflet
before using your ISIS iQ DUO
for the
first time.
PLEASE SAVE THESE INSTRUCTIONS.
Congratulations!
Soon you will discover what makes this ISIS iQ Breast Pump so uniquely yours.ISIS iQ is designed with
an electronic memory that learns and continues your gentle pumping rhythm. It gives you complete
control over your comfort, which means that pumping with ISIS iQ always feels natural and exactly
right for you.
Intelligent and intuitive... Its your iQ.
Let-down Massage Cushion
has petals that
flex in and out to gently massage the area
around your breast.This is intended to help
stimulate a fast, natural milk flow.
One-Touch Memory Control is right at your
fingertips.You can stop, start or adjust the
speed and suction level without removing
your hand from the pump.
Electronic Memory learns from you. Just
begin a comfortable pumping rhythm, press
a button and ISIS iQ automates it.
Pump, Store, Feed Convenience from
the AVENT Natural Feeding System. AVENT
products work together, so you never have
to transfer milk between containers.
Ultra Comfortable, Quiet and Effective
making it easier for you to continue giving
your baby the benefits of breast milk.
When using electrical products,especially when children are present,
basic safety precautions should always be followed.
READ ALL INSTRUCTIONS BEFORE USING THIS PRODUCT.
WARNING – To reduce the risk of fire, electrocution, or other personal injury:
• ISIS iQ DUO
is intended for repeated use by a single user only.
• Always unplug the breast pump motor from the electrical outlet immediately after use.
• Do not use while bathing.
• Do not place or store the product where it can be pulled or fall into water.
• Do not place or drop the pump motor,control handle, electric adaptor or wall plug cord into water or other liquid.
• Do not reach for a product that has fallen into water. Unplug from electrical outlet immediately.
• Close supervision is necessary when this product is used near children or persons with disabilities.
• Do not allow children or pets to play with the pump motor, tubing, power supply or accessories as these
parts may pose a choking or strangulation danger.
There are no serviceable parts inside the ISIS iQ DUO. Do not attempt to open, service or repair the
ISIS iQ DUO yourself.
• Before each use inspect the product, including mains cord, for signs of damage. Never operate this
product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged,
or has been submerged in water.
• Only use attachments recommended by AVENT.
• Do not use outdoors with the AC adaptor, where aerosol spray products are being used, or where oxygen
is being administered.
• Equipment not suitable for use in the presence of flammable anesthetic mixture with air, or with oxygen
or nitrous oxide.
• Only use the electric adaptor supplied with the product.
• Ensure the unit is not exposed to extreme heat or placed in direct sunlight.
This product is a personal care item and should not be shared between mothers.
• Do not attempt to remove the pump body from your breast while under vacuum.Turn the unit off and
break the seal between your breast and the pump funnel with your finger, then remove the pump from
your breast.
• Never use while pregnant, as pumping can induce labor.
• Never use when sleepy or drowsy.
CAUTION To reduce the risks of injury, device malfunction or failure:
• Do not leave product unattended when plugged into an electrical outlet.
• Never drop or insert any object into any opening or tubing.
• Do not shorten the tubing.
• Make sure the voltage of the electrical adaptor is compatible with the power source.
• First plug the adaptor into the breast pump motor.Then, attach the wall plug cord into the adaptor.
Lastly, insert plug into the wall socket.
• Although compliant with applicable EMC directives, this equipment may still be susceptible to
excessive emissions and/or may interfere with other more sensitive material.
Wash and sanitize the appropriate pump components before each use.
• Do not continue pumping for more than five minutes at a time if no result is achieved.
• Do not use antibacterial cleaners or detergents when cleaning breast pump parts.
• Never put the control handle or breast pump motor in water or sterilizer, as you can cause permanent
damage to the pump.
• If the pressure generated is uncomfortable or causing pain, turn the unit off, break the seal between
the breast and the pump body with your finger and remove the pump from your breast.
3
Warnings and Cautions
2
5
4
3
Clean Before Every Use (including first use):
Silicone Diaphragm (b)
White Valve (c)
Pump Body (d)
Reusable Base (e)
Let-down Massage Cushion
(g)
Funnel Cover/White Stand (h/f)
Cleaning Instructions:
These pump parts should be sanitized after every use.
Disassemble the pump before cleaning. Wash in warm soapy
water and rinse, or wash on the top rack dishwasher. Sanitize
in a steam sterilizer (electronic, electric or microwave) or by
boiling in water for 10 minutes.
Caution: Do not use antibacterial cleaners or detergents when
cleaning breast pump parts.
Clean with a Damp Cloth when Necessary:
Control Handle (a)
Tubing (i/j/k)
Note: The tubes are used for
suction and do not carry milk.
Double Pumping Connector (l)
Pump Motor (m)
Caution: NEVER put the control handle or pump motor in water
or a sterilizer, as you can cause permanent damage to the pump.
HELPFUL TIP!
The AVENT Electronic, Electric and
Microwave Steam Sterilizers are designed to
hold the washable components of the ISIS iQ
DUO and the entire ISIS
Manual Pump.
5
Make sure that ISIS iQ pump motor is turned off and unplugged before disassembling parts.
See section titled, ISIS iQ DUO Pump Parts Guide on page 1 for a description of the First (Control)
Pump and Second Pump.
6
Need Help? Call us at 1.800.54.AVENT or visit www.aventamerica.com
a
c
d
e
g
h
i
l
m
b
Second Pump
On the second pump, detach the transparent tube
from the double pumping connector. Remove the
double pumping connector by pulling it away from
the silicone diaphragm.
f
j
k
Remove the Let-down Massage Cushion
by gently pulling it away from the funnel
on the pump body.
Remove the white valve from the pump body.
Remove the silicone diaphragm by pulling
it away from the pump body.
Perform steps 3-5 on both the First
(Control Pump) and Second Pump.
Make sure that ISIS iQ is turned off and unplugged before cleaning.
1
First (Control) Pump
On the first (control) pump, remove the control
handle by pulling it away from the silicone
diaphragm.
First (Control) Pump
Second Pump
Disassembling ISIS iQ DUO
Cleaning and Sanitizing ISIS iQ DUO
Need Help? Call us at 1.800.54.AVENT or visit www.aventamerica.com
7
When using the pump for the first time,your ISIS iQ will have retained factory settings
stored in the memory as a result of quality control testing.If the blue One-Touch
Memory Control is pressed prior to squeezing the control handle upon first use the
pump will operate at these settings, which may or may not be comfortable for you.
We recommend that prior to engaging the automatic mode,you
establish a comfortable rhythm manually, then press the blue
One-Touch Memory Control to continue your preferred rhythm.
If you find that you are not expressing a lot of milk the
first few times you pump, don’t be discouraged. Learning
to express milk, like breastfeeding, takes practice.
Here are some tips that might make pumping easier:
1. Choose a time when you’re not rushed and won’t
be interrupted.
2. Choose a comfortable chair with a table nearby,
so you can set the ISIS iQ motor within reach.
3. Look at a photograph of your baby to help
encourage let-down.
4. Place a warm cloth on your breasts for a few minutes before you start
pumping.This encourages milk flow and can soothe painful breasts.
5. Warmth and relaxation can encourage milk flow.Try expressing after
a bath or shower.
6. Try expressing from one breast while your baby is feeding on the
other, or continue expressing just after a feed.
7. Reposition the pump on your breasts from time to time.This can
stimulate your milk ducts.
How quickly will the milk flow begin?
When pumping with the ISIS iQ DUO
, your milk should begin to flow after a
few compressions. If your milk does not begin to flow immediately, relax and
continue pumping. CAUTION: DO NOT CONTINUE PUMPING FOR MORE THAN 5
MINUTES AT A TIME IF NO RESULT IS ACHIEVED.Stop, and try expressing milk at
another time of day. If the process becomes painful, stop and consult your
lactation consultant or breastfeeding advisor.
How much milk can you expect?
It has been shown that double pumping boosts prolactin levels and stimulates
milk production so, if you can, use your ISIS iQ DUO regularly as a double pump.
On average you will need to pump for 10 minutes to express 60-120 mls or
2-4 ounces of milk. However, this is just a guide and varies from woman
to woman. If you find that you regularly express more than 4 ounces of milk
per session, attach a 9 oz/260 ml AVENT reusable base to the pump body.
8
You can use ISIS iQ DUO
as a:
Double Electric Pump
Manual Pump
(to use the ISIS
Manual Pump, see page 15)
Single Electric Pump
Preparing to Pump
Preparing to Pump
Need Help? Call us at 1.800.54.AVENT or visit www.aventamerica.com
10
Parts you will need for this step:
white valve clear silicone diaphragm
To ensure that the pump is
completely stable,insert the
pump base into the stand.
Let-down Massage Cushion
white stand
Double pumping? Assemble two pumps as shown below.
Single pumping? Assemble one pump as shown below.
pump body reusable base
9
Before assembling,make sure that you have correctly washed and sanitized the pump.
See section titled ‘Cleaning and Sanitizing ISIS iQ DUO on page 6.
1
3
4
2
Click the white valve into the pump body,
so that it fits securely into the small round
hole. Make sure the pointed side of the
valve is facing down.
Fit the clear silicone diaphragm into the
pump body. Ensure a perfect seal around
the rim by pressing down with your fingers.
(This is easier if assembled while the
diaphragm is wet.)
Screw the pump body onto the
reusable base until securely in place.
The Let-down Massage Cushion has petals
that flex in and out to gently massage the
area around the breast.This is intended to
help stimulate a fast, natural milk flow. When
using the breast pump without the Let-down
Massage Cushion, the maximum vacuum
level achievable will be higher.
Assembling Pump Bodies of ISIS iQ DUO
Assembling Pump Bodies of ISIS iQ DUO
Need Help? Call us at 1.800.54.AVENT or visit www.aventamerica.com
11
First (Control) Pump
First (Control) Pump
12
Parts you will need for this step:
assembled
pump body
(see pages 9-10)
Double Pumping?
double pumping
connector
control handle
Second Pump
Control Cable
Socket
pump motor
electric
adaptor
control
cable
transparent tubing
wall plug cord
Twin Tubing
Port
Double pumping? Complete the next step
with your second assembled pump body.
Single pumping? Complete the next step
with the remaining tube.
1
3a
2
4
5
3b
Push the control handle onto the
assembled pump body so that it sits
firmly on top of the silicone diaphragm.
This assembly becomes the First (Control)
Pump which contains the electronics
of the pump.
Click the control cable into the socket
on the control handle.
Then securely attach one of the
transparent tubes to the port on
the control handle.
Transparent
Tubing Port
Control Cable
Socket
Push the double pumping connector onto the
pump body so that it sits firmly on top of the
silicone diaphragm. Securely attach the other
transparent tube to the double pumping
connector. When ISIS iQ DUO is fully assembled,
the Second Pump will mimic simultaneously the
speed and suction of the First (Control) Pump.
If you are single pumping, you can keep
the transparent tube out of the way by
attaching it to the white clip.
Securely attach the twin tubing
to the ports on the pump motor.
Connect the control cable
into the adjacent socket.
Connect the electric adaptor to power socket
on the pump motor.
Then connect the wall plug cord to the electric
adaptor and insert the plug into the wall outlet.
Connecting the Electronics of ISIS iQ DUO
Connecting the Electronics of ISIS iQ DUO
See section titled, ISIS iQ DUOPump Parts
Guide on page 1 for a description of First
(Control) Pump and Second Pump.
See section titled, ISIS iQ DUO Pump Parts Guide
on page 1 for a description of First (Control) Pump
and Second Pump
HELPFUL TIP!
The light on top of the ISIS iQ DUO Motor indicates the pump mode:
Flashing ORANGE Light: Pump is in warm-up mode.Wait for the continuous GREEN light.
C
ontinuous GREEN Light: Manual pumping mode.You control the speed and pressure
of the pump.
Flashing GREEN Light: Automatic pumping mode. ISIS iQ will mimic your last established
pumping rhythm and level of suction.
Flashing RED Light: Consult the Troubleshooting Guide on page 21.
14
Need Help? Call us at 1.800.54.AVENT or visit www.aventamerica.com
13
Before you begin pumping,make sure that you have correctly washed, sanitized and
assembled the pump.Consult the ‘Preparing to Pump Section on page 7 for tips on
stimulating let-down and milk flow.
7
8
6
5
4
3
1
2
ISIS iQ Mimics Your Pumping:To create a natural breastfeeding
rhythm,we suggest you hold down on the handle for 3 seconds,
then release and repeat the pattern for the next compression.
Next, press the blue One-Touch Memory Control on the handle.
The mode light on the pump motor will change from solid GREEN
to flashing GREEN and ISIS iQ will mimic the rhythm of the last
two compressions.
Note:You do not need to compress the handle fully, only until it feels comfortable.The
further you compress the handle,the more suction the pump will provide. If the pressure
is uncomfortable,stop the automated pumping by pressing the One-Touch Memory
Control and breaking the seal between your breast and pump funnel with your finger.
Changing the Speed and Level of Suction: Press the blue
One-Touch Memory Control on the handle again, and the pump
will revert to manual control.The light will turn from flashing
GREEN to solid GREEN. Establish a comfortable speed and level
of suction. Press the blue One-Touch Memory Control again,
and ISIS iQ will continue the same pumping rhythm.
Ending Pumping Session: Press the blue One-Touch Memory
Control, break the seal between your breast and pump funnel
with your finger and remove the pump from your breast.Turn the
pump off and unplug at the power source. ISIS iQ will remember
and save the speed and suction level of your last two compressions.
Unscrew the base after milk is collected. If any milk remains in the
pump body, pour it into the base. Do not overfill the base.Wash
and re-sanitize all necessary parts before the next use.
Next time you turn your pump on: Resuming Saved Session? Turn on the pump as in
Step 1. Complete Step 2. Press the blue One-Touch Memory Control.This engages the
automatic pumping mode.The pump will continue with the rhythm of the last two
saved compressions of the milk expression phase. Continue pumping as described in
Step 4. Need to re-establish let-down? If you need to establish let-down, turn on the
pump as in Step 1. Complete Step 2. Squeeze the handle with shallow quick strokes
and proceed as described in Step 3.
Wash your hands thoroughly and make sure your breasts
are clean.
Turn on Pump:When the flashing ORANGE light changes to a
continuous GREEN light, the pump is ready to use.
If the light is flashing RED, refer to the Troubleshooting Guide
on page 21.
Form a Seal: Press the pump against your breast, so that your
nipple fits into the funnel. A seal should form between the
pump and your breast. (If double pumping, press a pump
to each breast.)
Let-down: Let-down is your bodys physiological response to
the suckling action of your baby on the breast.This stimulates
the breast to produce milk and send it towards the nipple
where it is available for baby.
To initiate let-down, begin by squeezing the handle with
shallow quick strokes.This is intended to imitate your baby’s
natural suckling pattern. At the same time you are doing this,
you are enabling the petals on the Let-down Massage Cushion
to flex in and out around the areola, creating a massaging
effect.This is intended to help stimulate the natural let-down
reflex. Let-down can occur immediately after a few strokes
and should not take longer than 5 minutes (refer to page 7
on Preparing to Pump).You can choose to automate this
let-down phase by pressing the blue One-Touch Memory
Control or you can continue to pump manually.
Milk Expression: Milk Expression occurs after let-down
is achieved and milk begins to flow. It is the phase that
is induced by the baby’s deeper more comfortable
sucking rhythm.
If you did not automate the let-down rhythm, please skip to
Step 5. If you have automated the let-down phase in Step 3,
press the blue One-Touch Memory Control to end the let-down
rhythm.You can now begin to establish a comfortable
pumping rhythm and level of suction that can be
maintained throughout your pumping session.
CONSULT THE GUIDELINES FOR STORING EXPRESSED BREAST MILK ON PAGE 19 & 20.
Pumping with ISIS iQ DUO
Pumping with ISIS iQ DUO
White valve
Pump body
Reusable base (4 oz/125 ml)
Stand (same as )
Let-down Massage Cushion
TM
Funnel cover (same as )
Need Help? Call us at 1.800.54.AVENT or visit www.aventamerica.com
15
Clear pump cover
Silicone diaphragm with a stem
Forked handle
Wash and sanitize all parts before use. See section titled
‘Cleaning the ISIS Manual Pump on page 15.
16
You may want to use the ISIS Manual Pump when you need a cord-free alternative to
the ISIS iQ DUO
.While the ISIS Manual Pump uses many of the same parts as the ISIS
iQ DUO,please note the parts shaded in green are specific to the ISIS Manual Pump.
Parts specific to the ISIS
Manual Pump are included
in a separate bag:
Cleaning the ISIS Manual Pump
Caution: Do not use antibacterial cleaners or detergents when cleaning breast pump parts.
Every time before use (including first use):
Clean all parts of the ISIS Manual Pump on the top rack of the dishwasher, or in warm
soapy water and rinse.The pump should be sanitized after every use. All parts of the
ISIS Manual Breast Pump are sterilizer safe. Sanitize in a steam sterilizer (electronic,
electric or microwave), or by boiling in water for 10 minutes.
1
Wash your hands thoroughly. Click the white valve
into the pump body so that it fits securely into the
small round hole. Make sure the pointed side of the
valve is facing down.
2
3
Twist the reusable base onto the pump
body until securely in place.To ensure the
pump is completely stable, insert the
pump base into the stand.
4
Fit the Let-down Massage Cushion
TM
onto the
pump funnel. Secure the rim of the Let-down
Massage Cushion around the funnel, so that there
are no gaps. (This is easier if assembled while the
Let-down Massage Cushion is wet.)
5
Place the forked end of the handle under the
rounded tip of the diaphragm stem. Push down
gently on the handle until it clicks into place.
6
Click the pump cover onto the pump body.
ISIS Manual Pump
c
d
e
f
f
g
h
h
u
v
w
u
v
w
c
d
e
f
g
h
Fit the silicone diaphragm with stem into the
pump body. Ensure a perfect seal around the rim
by pressing down with your fingers. (This is easier
if assembled while the diaphragm is wet.)
white stand
ISIS
Manual Pump – Parts Guide Assembling the ISIS
Manual Pump
Need Help? Call us at 1.800.54.AVENT or visit www.aventamerica.com
Before you begin pumping,make sure you have washed, sanitized and carefully
assembled the ISIS Manual Pump. Consult the ‘Preparing to Pump on page 7 for tips
about stimulating let-down and milk flow.
1817
2
Initiate let-down: Squeeze the handle with shallow,
quick strokes, until milk starts to flow. Do not use full
compression on the handle.
3
Begin Pumping:When you see milk beginning to flow,
you can establish a comfortable pumping rhythm
and level of suction. Create a natural breastfeeding
rhythm by holding down on the handle for 3 seconds,
then releasing, and repeating that pattern for
each compression.
Note: You do not need to compress the handle fully, only until it
feels comfortable.The further you compress the handle, the more
suction the pump will provide.
4
After milk is collected, unscrew the pump body
from the base.
Caution: Do not continue pumping for more than five minutes
at a time if no result is achieved.Try expressing at another time
during the day.
1
Wash your hands thoroughly and make sure your
breasts are clean.
Form a Seal: Press the pump against your breast, so
that your nipple fits into the funnel. A seal should form
between the pump and your breast.
Storage Base
After sanitizing all parts, click the
sealing disc into the screw ring.
Screw the ring onto the reusable base.
Screw ring (r)
Sealing disc (t)
Reusable base (e)
AVENT Natural Shape Nipple
After sanitizing all parts, click the
nipple into the screw ring. Screw the
travel cover into the ring. Attach the
dome cap over the top of the nipple.
Dome cap (p)
Screw ring (r)
Nipple (q)
Travel cover (s)
d
e
g
h
p
q
r
r
s
s
t
Using the ISIS
Manual Pump Keeping Parts Clean and Compact for Travel
Pump
After sanitizing all parts, insert the white valve and
diaphragm into the pump body. Clip the funnel cover
over the Let-down Massage Cushion
and screw the
travel cover onto the bottom of the pump body.Then
put the assembled items in the gray drawstring bag.
Travel cover (s)
Pump body (d)
Let-down Massage Cushion (g)
Funnel cover (h) (also used as a stand when pumping)
Need Help? Call us at 1.800.54.AVENT or visit www.aventamerica.com
19
With AVENT, you never have to transfer milk
between containers because you pump,
store and feed with the same base.
By using the AVENT Natural Feeding System, you
preserve valuable nutrients that can get lost if
breast milk is transferred.
With your ISIS iQ DUO
or ISIS
Manual Pump, you can express milk directly into
VIA Disposable Cups.VIA Cups are safer and sturdier than disposable liners,
and offer better protection for pumping, storing and feeding breast milk.
Get VIA and Get Going!
Twist-on lid seals tightly to VIA Cup for leak-proof storing or freezing
Writable and stackable cups make it easy to organize
• Compatible system lets you pump,store and feed using the same cup
• Sturdy VIA Cups heat easily and quickly in a bottle warmer
With all the assurances you get from VIA, why trust any other disposable?
AVENT
®
VIA
:
The Safest, Strongest
Disposable Ever!
20
Guidelines for Storing Expressed Breast Milk
°
Refrigerate breast milk immediately. Refrigerate for up to 48 hours in the back of the
refrigerator, not in the door.
°
Freeze for up to 3 months, or 6 months in a zero-degree freezer.
°
Frozen breast milk can be defrosted overnight in the refrigerator, thawed in warm water
or heated on the lowest setting of a bottle warmer or baby food warmer.
°
NEVER refreeze breast milk.
°
If you express small amounts of milk throughout the day, you can top up the milk
container by keeping it in the refrigerator and adding to it. Make sure the milk is used
within 48 hours of the first expression, or store it in the freezer.
°
DO NOT add fresh breast milk to already frozen milk.
Note: Only milk collected with a clean, sanitized pump should be stored to be fed to your baby.Sanitize
Breast Milk Storage Containers before use or express milk directly into VIA
Disposable Cups.
Never immerse a frozen bottle or liner in boiling water as this may cause it
to crack/split.
Transporting Expressed Breast Milk
°
Please refer to Tote Bag Instructions for complete
directions on how to store and transport breast
milk using the Thinsulate
carriers.
°
When removed from the freezer, four AVENT Gel
Packs will keep one 4 oz or one 9 oz container of
freshly expressed breast milk sufficiently chilled
inside a Thinsulate carrier and insulated bag for up
to 6 hours.Ensure that both the storage containers
and carriers are placed upright in the bag to prevent
leaking. Also make sure that the Thinsulate carriers
are completely zipped.
°
Be sure to keep the gel packs frozen until they
are ready to use and refrigerate milk immediately
after removing it from the insulated bags.
°
In hot climates,avoid storing Thinsulatecarriers or
the travel bag containing expressed milk in a car,
office,cabinet etc.Milk must be sufficiently chilled
to avoid spoilage.
Please note: Milk storage times
vary based on collection and
storage conditions.This storage
information is only a suggestion.
Please contact your doctor or
lactation consultant about milk
storage guidelines.
After expressing milk into the AVENT reusable
base, insert a sealing disc into the screw ring
and twist it onto the base.To feed from the
same base, insert the AVENT Natural Shape
Nipple into the screw ring.
Storing Your Expressed Breast MilkStoring Your Expressed Breast Milk
21
Lack of suction
No milk being
expressed
°
Ensure the pump is correctly assembled and that suction is being created.
°
Relax and try again, as expression may improve after practice.
°
Refer to the ‘Preparing to Pump section on page 7.
Pain when
expressing
°
You may be pumping too hard. You do not need to use all the suction
the pump can generate.Try compressing the handle halfway.
°
Try holding down the pump handle for 2-3 seconds per compression.
°
Consult your health professional or breastfeeding advisor.
Milk is drawn up
the Let-down
Massage Cushion
°
Try leaning slightly forward.
°
Remove and re-fit the Let-down Massage Cushion to ensure it is firmly
attached and pushed far enough down the center of the funnel.
Some women may prefer to use the pump without the Let-down Massage Cushion.The Let-
down Massage Cushion has petals that flex in and out to gently massage the area around the
breast.This is intended to help stimulate a fast, natural milk flow. When using the breast pump
without the Let-down Massage Cushion,the maximum vacuum level achievable will be higher.
Cracking or
discoloration
of pump parts
°
Avoid contact with antibacterial detergents or cleaners as they can damage the
plastic. Combinations of detergents, cleaning products, sanitizing solution,
softened water and temperature fluctuations may, under certain circumstances,
cause the plastic to crack. If this occurs, do not use.The pump bodies and breast
milk containers are dishwasher safe but food colorings may discolor them.
Follow guidelines in ‘Cleaning and sanitizing your ISIS iQ DUO
on page 6 of the
instruction booklet.
Lost or broken parts
°
Contact AVENT for replacements.
Call 1.800.54.AVENT or visit www.aventamerica.com
Pump not responding
to pressing of the
control handle
°
Ensure the pump is correctly assembled and switched on with the power
indicator illuminated GREEN.
°
Make sure the cables between the electric wall socket and the pump are
correctly connected.
Pump light
flashing RED
°
If the pump stops working and the power light is flashing RED then a fault has
been detected.
°
3 flashes, delay, 3 flashes, etc – the ISIS iQ has detected a vacuum fault. Switch
off the motor and check tubing and connections for obstructions or damage.
°
2 flashes,delay, 2 flashes, etc – the ISIS iQ has detected that it is over the acceptable
temperature.Switch off the motor. Ensure unit is not exposed to heat sources or
sitting in direct sunlight. Allow unit to stabilize before trying again.
°
Continuous flashing – the pump has detected that the control cable has been
incorrectly fitted/not fitted or the cable is damaged.
°
Check that all the pump components have been assembled
correctly and that the white valve is positioned correctly.
°
Ensure that the silicone diaphragm and Let-down Massage Cushion
are fitted
securely to the pump body and a perfect seal is created, making sure to push
the Let-down Massage Cushion far enough down the center of the funnel.
°
Make certain that the tubing connections and control handle are firmly in place.
22
Need Help? Call us at 1.800.54.AVENT or visit www.aventamerica.com
Key to product base label
TYPE B APPLIED PART GENERAL WARNING
FOLLOW OPERATING
INSTRUCTIONS
ETL LISTED MARK –
CANADA/UNITED STATES
LISTED
3045297
CLASS II EQUIPMENT
FOR INDOOR USE ONLY
Technical Specifications:
°
Mains Input Voltage 100 – 240 VAC
°
Mains Input Current 1.5A
°
Mains Input Frequency 50 – 60 Hz
°
Supply voltage fluctuations not exceeding
+/- 10% of the nominal voltage
°
Ambient temperature range: +10° C to
+40° C (+50° F to +104° F)
°
Relative Humidity range: 30% to 75%
°
Atmospheric Pressure: 700 to 1060hPa
°
Equipment rated for continuous operation
Technical SpecificationsTroubleshooting Guide
23
Tire-lait régulateur Second tire-lait
Moteur du tire-lait
1 poignée de commande
2 diaphragmes en silicone
2 valves blanches
2 bols
4 gobelets réutilisables
(2 x 4 oz/125 ml et 2 x 9 oz/260 ml)
2 socles (identiques à )
2 coussins masseurs
MD
2 protège-entonnoirs (identiques à )
1 câble pilote
2 tubes transparents
1 double tube
1 double connecteur à pompage
1 moteur de tire-lait
1 adaptateur électrique
1 cordon d’alimentation
2 capuchons
2 tétines nouveau-né
2 bagues d’étanchéité
2 garde-tétines
2 disques d’étanchéité
a
b
c
d
e
f
f
g
h
i
j
k
l
m
n
o
p
q
r
s
t
a
b
c
d
e
f
b
c
d
e
f
g
h
g
h
i
j
j
k
l
m
n
o
p
q
r
s
t
h
24
La touche
de commande
1 poignée de
commande
Moteur du tire-lait
Témoin
lumineux
Prise pour câble
pilote
Prise de
courant
Port pour double
tube
Prise pour câble pilote
Port pour
double tube
NE JAMAIS DÉSINFECTER OU IMMERGER DANS L'EAU
NE JAMAIS DÉSINFECTER OU IMMERGER DANS L'EAU
Interrupteur
marche/arrêt
1 poignée de commande
Besoin d'aide? Appelez-nous au 1 800.54.AVENT ou visitez www.aventamerica.com
Les pièces b à g assemblées forment un des bols du tire-lait.Lorsque la poignée de commande (a) est
fixée sur ce bol,il devient le tire-lait régulateur. Lorsque le double connecteur à pompage (l) est fixé à ce
bol,il devient le second tire-lait.
Toutes les pièces nécessaires au fonctionnement de ISIS iQ sont illustrées ci-contre. Si toutefois une pièce était
manquante ou si vous avez des questions, veuillez communiquer avec notre service de soutien au 1.800.54.AVENT
ou visitez www.aventamerica.com.
Guide des pièces du tire-lait ISIS iQ DUO
MD
Le guide des pièces du tire-lait ISIS iQ DUO
MD
– en
détail
Besoin d'aide? Appelez-nous au 1 800.54.AVENT ou visitez www.aventamerica.com
Exprimer manuellement
avec ISIS
MD
Guide des pièces du tire-lait manuel ISIS
37
Nettoyer le tire-lait manuel ISIS 37
Assembler le tire-lait manuel ISIS 38
Utiliser le tire-lait manuel ISIS 39
Contenu
Tire-lait (Simple et double)
Guide des pièces du tire-lait
ISIS iQ DUO 23-24
Avertissements et mises en garde 25
Démonter ISIS iQ DUO 27
Nettoyer et désinfecter ISIS iQ DUO 28
Préparation pour tirer du lait 29-30
Assembler les bols
d'ISIS iQ DUO 31-32
Brancher les composants
électroniques du ISIS iQ DUO 33-34
Tirer du lait avec ISIS iQ DUO 35-36
Garder les pièces propres et le
tire-lait compact en déplacement 40
Conservation du lait maternel 41-42
Guide de dépannage 43
Données techniques 44
26
Veuillez prendre quelques minutes pour lire
attentivement ce feuillet d'information avant
d'utiliser ISIS iQ DUO
MD
pour la première fois.
CONSERVEZ PRÉCIEUSEMENT CE FEUILLET.
Félicitations!
Bientôt vous découvrirez ce qui rend votre tire-lait ISIS iQ si unique. ISIS iQ a une mémoire électronique
intégrée qui reproduit votre rythme d'extraction en douceur.Vous contrôlez complètement le niveau
de votre confort. Ainsi, extraire votre lait avec ISIS iQ vous semblera tout à fait naturel.
Intelligent
and Intelligent et intuitif... c'est tout à fait votre iQ.
Le coussin masseur
MD
est doté de pétales qui
massent la région sous le mamelon et stimulent
le réflexe d’éjection du lait, entretenant la
rapidité de son débit en douceur.
La touche de commande est au bout de vos
doigts.Vous pouvez arrêter,mettre en marche
ou modifier la vitesse et la puissance d'aspiration
sans retirer votre main du tire-lait.
La mémoire électronique mémorise vos
gestes. Commencez par tirer manuellement,
appuyez sur la touche et ISIS iQ prend le relais
automatiquement.
Aspirez et conservez votre lait, et
nourrissez bébé à votre convenance grâce
au système d'alimentation naturel AVENT. Les
produits AVENT s'adaptent les uns aux autres.
Vous n'avez donc pas à transvider votre lait
d'un contenant à l'autre.
Ultra confortable, silencieux et efficace, ce
tire-lait vous permet aisément de faire profiter
à votre bébé des bienfaits du lait maternel.
Lorsque vous utilisez des appareils électriques, particulièrement en présence d’enfants,
vous devez respecter certaines règles de sécurité.
LISEZ ATTENTIVEMENT LE MODE D'EMPLOI AVANT L'UTILISATION DE CE PRODUIT.
AVERTISSEMENTS – Pour réduire le risque d’incendie, d’électrocution ou de
blessures :
ISIS iQ DUO
MD
est destiné à un usage répété par une seule utilisatrice.
Débranchez toujours le moteur du tire-lait immédiatement après usage.
N'utilisez pas lorsque vous prenez un bain.
Ne rangez pas l’appareil là où il pourrait tomber ou être tiré à l'eau.
N'immergez et ne plongez pas le moteur du tire-lait,la poignée,l'adaptateur ou le cordon d'alimentation
dans l’eau ou autre liquide.
Ne saisissez pas un appareil qui est tombé à l’eau. Débranchez-le immédiatement.
Une étroite surveillance s’impose lorsqu’on utilise cet appareil en présence d’enfants ou de personnes
handicapées.
Ne laissez pas les enfants ou les animaux domestiques jouer avec le moteur, les tubes, le bloc d'alimentation
ou les accessoires puisque ces éléments pourraient provoquer un risque d'étouffement ou d'étranglement.
Aucune pièce interne d'ISIS iQ ne peut être réparée par l’utilisateur. N'essayez pas d'ouvrir l'appareil pour en
faire l'entretien ou pour tenter de le réparer vous-même.
Avant chaque utilisation,examinez l'appareil, y compris les cordons d'alimentation. N'utilisez pas l’appareil si
la fiche ou le cordon sont abîmés ou encore si l’appareil fonctionne mal, s’il a été échappé ou endommagé
ou s’il a été immergé dans l’eau.
N’utilisez que les accessoires recommandés par AVENT.
Ne vous en servez pas à l’extérieur avec l’adaptateur secteur, là où on utilise des aérosols ni là où on
administre de l’oxygène.
Cet appareil ne doit pas être utilisé en présence d'un mélange d'anesthésique inflammable et d'air,
d'oxygène ou d'acide nitrique.
N’utilisez que l’adaptateur électrique fourni avec ce produit.
N'exposez pas l'appareil à des températures extrêmes ou aux rayons directs du soleil.
Pour des raisons d’hygiène, il est préférable de ne pas partager cet appareil entre mères.
N'essayez pas de retirer le bol de votre sein pendant l'aspiration. Arrêtez le moteur et brisez l’étanchéité
en glissant un doigt entre votre sein et l’entonnoir.
Ne l'utilisez pas si vous êtes enceinte : l'expression du lait peut provoquer l'accouchement.
Ne l'utilisez pas en cas de somnolence ou d’envie de dormir.
MISES EN GARDE – Pour réduire les risques de blessures, de mauvais
fonctionnement ou de défaillance :
Ne vous éloignez pas de l’appareil lorsqu’il est branché.
N’introduisez aucun objet dans les ouvertures ou dans les tubes.
Ne raccourcissez pas les tubes.
Assurez-vous que la tension du courant sortant de l’adaptateur est compatible avec la source de courant.
Branchez d’abord l’adaptateur dans le moteur du tire-lait.Ensuite, insérez le cordon d’alimentation dans
l’adaptateur. Enfin, branchez le cordon dans la prise murale.
Bien que conforme aux normes de CEM, ce produit pourrait créer des perturbations électromagnétiques
ou gêner d'autres appareils particulièrement sensibles.
• Lavez et stérilisez les pièces du tire-lait avant chaque utilisation.
• Même sans résultat, ne continuez pas à pomper plus de cinq minutes à la fois.
• N'utilisez pas de nettoyants ou de détergents antibactériens pour laver les pièces du tire-lait.
• Ne placez jamais la poignée ou le moteur dans l'eau ou dans le stérilisateur, cela pourrait les abîmer
de façon permanente.
Si l’expression du lait devient inconfortable,voire douloureuse, arrêtez le moteur, brisez l’étanchéité
en glissant un doigt entre votre sein et le bol de l'entonnoir et retirez le tire-lait de votre sein.
25
Avertissements et mises en garde
2
5
4
3
Nettoyez avant chaque usage (y compris lors de la première utilisation) :
Diaphragme en silicone (b)
Valve blanche (c)
Bol (d)
Gobelet réutilisable (e)
Coussin masseur
MD
(g)
Protège-entonnoir/socle blanc (h/f)
Instructions de nettoyage :
Les pièces de ce tire-lait devraient être désinfectées après
chaque utilisation. Démontez le tire-lait avant de le nettoyer.
Lavez à l'eau chaude savonneuse et rincez ou passez au lave-
vaisselle dans le panier supérieur. Désinfectez dans un stérilisateur vapeur (électronique,
électrique ou micro-ondes) ou en faisant bouillir dans l'eau durant 10 minutes.
Mise en garde : N’utilisez pas de nettoyants ou de détergents antibactériens
pour nettoyer les pièces de votre tire-lait.
Nettoyez avec un chiffon humide lorsque nécessaire :
Poignée de commande (a)
Tubes (i/j/k)
Note : Les tubes servent à la
succion et non à acheminer le lait.
Double connecteur à pompage (l)
Moteur du tire-lait (m)
Mise en garde : NE JAMAIS immerger dans l’eau ou stériliser la poignée de
commande ou le moteur du tire-lait,vous pourriez causer des dommages irréparables.
CONSEIL PRATIQUE!
Les stérilisateurs vapeurs électronique,
électrique ou micro-ondes AVENT sont conçus
spécifiquement pour les pièces lavables du tire-lait
ISIS iQ DUOet pour le tire-lait manuel ISIS
MD
.
27
Mettez le tire-lait ISIS iQ hors tension et débranchez-le avant de le démonter. Consultez la section
intitulée « Guide des pièces d'ISIS iQ DUO » à la page 23 pour la description du tire-lait régulateur
et du second tire-lait.
28
Besoin d'aide? Appelez-nous au 1 800.54.AVENT ou visitez www.aventamerica.com
a
c
d
e
g
h
i
l
m
b
Second tire-lait
Enlevez le tube simple transparent du double
connecteur à pompage du second tire-lait. Dégager
délicatement le double connecteur à pompage du
diaphragme en silicone.
f
j
k
Retirez le coussin masseur
MD
en le
dégageant délicatement de l'entonnoir.
Retirez la valve blanche du bol.
Retirez le diaphragme en silicone en
le dégageant du bol.
Suivez les instructions de 3 à 5 pour
démonter le tire-lait régulateur et le
second tire-lait.
Mettez ISIS iQ hors tension et débranchez-le avant de le nettoyer.
1
Tire-lait régulateur
Retirez la poignée de commande du bol du
tire-lait régulateur en la dégageant délicatement
du diaphragme en silicone.
Tire-lait régulateur
Second tire-lait
Démonter ISIS iQ DUO
MD
Nettoyer et désinfecter ISIS iQ DUO
MD
Besoin d'aide? Appelez-nous au 1 800.54.AVENT ou visitez www.aventamerica.com
29
Le tire-lait ISIS iQ a gardé en mémoire le réglage par défaut de l'usine réalisé pour les tests de
contrôle de la qualité.Si vous appuyez sur la touche de commande bleue avant de presser la
poignée de commande lors de la première utilisation,elle fonctionnera selon les paramètres
enregistrés,ce qui peut s'avérer inconfortable pour vous.Nous vous conseillons d'établir votre
rythme d'extraction manuellement et ensuite d'appuyer
sur la touche de commande bleue,la mémoire de l'appareil
prendra ensuite le relais et reproduira le rythme qui vous convient.
Ne vous découragez pas si vous n'arrivez pas à exprimer une
grande quantité de lait au début. L’utilisation d’un tire-lait est
une habitude qui s’acquiert.Voici quelques conseils qui
pourraient vous aider :
1. Choisissez un moment où vous n’êtes pas pressée et où
vous ne serez pas interrompue.
2. Choisissez une chaise confortable près d'une table où
sera posé votre tire-lait ISIS iQ, ainsi vous pourrez le
réglez facilement.
3. Regarder une photo de votre bébé pourrait déclencher le
réflexe d’éjection du lait.
4. Une débarbouillette chaude et humide appliquée quelques minutes sur les seins
avant de commencer à tirer, favorise le réflexe d’éjection du lait et soulage les
seins gonflés.
5. Votre lait coule mieux quand vous êtes détendue et que vous êtes au chaud.
Essayez d’en tirer après un bain ou une douche.
6. Essayez de tirer d’un sein quand votre bébé tète de l’autre, ou bien tirez juste
après une tétée.
7.
Changez la position du tire-lait de temps en temps pour stimuler le canal galactophore.
Le lait commencera-t-il à s'écouler rapidement?
Lorsque vous pompez avec ISIS iQ DUO
MD
votre lait devrait commencer à couler
après quelques pressions. Ne vous inquiétez pas s’il ne coule pas tout de suite.
Détendez-vous et continuez à pomper. MISE EN GARDE : MÊME SANS RÉSULTAT, NE
CONTINUEZ PAS À POMPER PLUS DE 5 MINUTES À LA FOIS. Essayez plutôt à un autre
moment. Si le procédé s’avérait douloureux, arrêtez et demandez conseil à une
consultante en allaitement.
Quelle est la quantité de lait à prévoir?
Il a été démontré que le double pompage stimule le niveau de prolactine et, par
conséquent, la production de lait. Donc, utilisez votre ISIS iQ DUO en mode double
pompage le plus souvent possible. En moyenne, il faut 10 minutes pour tirer de
60 à 120 ml de lait. Ceci n’est donné qu’à titre d’indication et varie d’une maman
à l’autre. Si vous vous rendez compte que vous tirez généralement plus de 110 ml
par séance, veuillez utiliser les gobelets réutilisables 260 ml AVENT.
30
Vous pouvez utiliser ISIS iQ DUO
MD
comme un :
Tire-lait à double pompage
Tire-lait en mode manuel
(pour l'utiliser en mode manuel,
voir page 37)
Tire-lait à simple pompage
Préparation pour tirer du lait
Préparation pour tirer du lait
Besoin d'aide? Appelez-nous au 1 800.54.AVENT ou visitez www.aventamerica.com
32
Pièces nécessaires à cette étape :
valve blanche
diaphragme en
silicone transparent
Pour plus de stabilité,
posez le gobelet sur le socle
Coussin masseur
MD
Socle blanc
Double pompage? Assembler les deux tire-laits tels qu'illustrés ci-dessous.
Simple pompage? Assembler le tire-lait tel qu'illustré ci-dessous.
bol de l'entonnoir Gobelet réutilisable
31
Avant d'assembler ces pièces,assurez-vous d'avoir lavé et désinfecté le tire-lait.Voir
section intitulée « Nettoyer et désinfecter ISIS iQ DUO » à la page 28.
1
3
4
2
Tenez l’entonnoir à l’envers et poussez
fermement la petite valve blanche
dans le fond du bol de l’entonnoir.
Assurez-vous que le côté pointu de
la valve est en dessous.
Enfoncez le diaphragme en silicone
transparent dans le bol, les bords bien
repliés sur le pourtour. Pressez les doigts
sur toute la circonférence pour assurer que
l’étanchéité est parfaite. (La tâche est
facilitée quand le diaphragme est mouillé.)
Vissez fermement le bol sur
le gobelet réutilisable.
Le coussin masseur est doté de pétales
qui massent la région sous le mamelon
et stimulent le réflexe d’éjection du lait,
entretenant la rapidité de son débit en
douceur. Lorsque vous utilisez le tire-lait sans
son coussin masseur, le niveau de vide
maximal pourrait être plus élevé.
Assembler les bols d'ISIS iQ DUO
MD
Assembler les bols d'ISIS iQ DUO
MD
Besoin d'aide? Appelez-nous au 1 800.54.AVENT ou visitez www.aventamerica.com
33
Tire-lait régulateur
Tire-lait régulateur
34
Pièces nécessaires à cette étape :
Bol de
l'entonnoir
assemblé (voir
pages 31-32)
Double pompage?
Double connecteur à
pompage
Poignée de
commande
Second tire-lait
Prise pour
câble pilote
Moteur du tire-lait
Adaptateur
électrique
Câble
pilote
Tube transparent
Cordon d’alimentation
Port pour
double tube
Double pompage? Suivez les étapes suivantes
pour assembler le second bol du tire-lait.
Simple pompage? Suivez l'étape
suivante avec le tube qui reste.
Voir la section intitulée « Guide des pièces du
tire-lait ISIS iQ DUO » à la page 23 pour la
description du tire-lait régulateur et du
second tire-lait.
Voir la section intitulée « Guide des pièces du tire-
lait ISIS iQ DUO » à la page 23 pour la description
du tire-lait régulateur et du second tire-lait.
1
3a
2
4
5
3b
Insérez la poignée de commande dans
le bol assemblé de manière à ce qu’elle
soit fixée solidement au diaphragme en
silicone. Ce bol assemblé devient le
tire-lait régulateur doté des composants
électroniques.
Branchez le câble pilote sur la prise de
la poignée.
Insérez solidement un des tubes
transparents au port de la poignée de
contrôle.
Port pour
tube
transparent
Prise pour
câble pilote
Insérez le double connecteur à pompage dans
le second bol de manière à ce qu'il soit fixé
fermement au diaphragme en silicone. Branchez
solidement l'autre tube transparent au double
connecteur à pompage. Lorsque ISIS iQ DUO est
complètement assemblé, le second tire-lait
reproduit les paramètres du tire-lait régulateur.
Si vous utilisez le simple pompage, vous
pouvez attacher le tube transparent, devenu
inutile, à l'agrafe blanche.
Insérez le double tube aux ports
situés à l'arrière du moteur du tire-lait.
Branchez le câble pilote sur la
prise adjacente.
Branchez l'adaptateur électrique sur la prise
du moteur du tire-lait.
Ensuite, branchez le cordon d'alimentation
dans l'adaptateur électrique, puis le cordon
dans la prise murale.
Brancher les composants électroniques d'ISIS iQ DUO
MD
Brancher les composants électroniques d'ISIS iQ DUO
MD
CONSEILS UTILES!
Le témoin lumineux sur le moteur d'ISIS iQ DUO indique le mode du tire-lait :
Témoin lumineux ORANGE clignotant : Le tire-lait est en mode réchauffage.
A
ttendez le témoin lumineux VERT en continu.
Témoin lumineux VERT en continu : mode manuel.Vous contrôlez la vitesse
et la pression du tire-lait.
Témoin lumineux VERT clignotant : mode automatique. ISIS iQ reproduit les
paramètres gardés en mémoire des dernières compressions.
Témoin lumineux ROUGE clignotant : Consultez le Guide du dépannage de la page 43.
36
Besoin d'aide? Appelez-nous au 1 800.54.AVENT ou visitez www.aventamerica.com
35
Avant de commencer à exprimer votre lait,assurez-vous que vous avez soigneusement lavé,
désinfecté et correctement assemblé le tire-lait. Consultez la section « Préparation pour tirer du
lait » à la page 29 pour des conseils sur la façon de stimuler le réflexe d'éjection.
7
8
6
5
4
3
1
2
ISIS iQ reproduit votre rythme : Pour établir un rythme de succion
naturel, pressez la poignée durant 3 secondes puis relâchez-la.
Répétez. Ensuite, appuyez sur la touche de commande bleue sur
la poignée. Le témoin lumineux vert du tire-lait se mettra à clignoter
et ISIS iQ reproduira les paramètres des deux dernières compressions.
Note : Ne pressez la poignée qu'à moitié,ou jusqu'à ce que vous vous sentiez à l'aise.
Souvenez-vous que plus vous pressez la poignée, plus le tire-lait aspire.Si la pression
est inconfortable,interrompez le mode automatique en appuyant sur la touche de
commande et brisez l'étanchéité en glissant un doigt entre votre sein et l'entonnoir.
Modifier la vitesse et le niveau de succion : Appuyez à nouveau
sur la touche de commande bleue de la poignée, le tire-lait passe
au mode manuel. Le témoin lumineux VERT cesse de clignoter et
devient VERT en continu. Établissez un rythme et un niveau de
succion confortables. Appuyez à nouveau sur la touche de
commande bleue de la poignée, et ISIS iQ prendra le relais en
gardant en mémoire les nouveaux paramètres.
Interrompre la séance de pompage : Appuyez sur la touche de
commande, brisez l'étanchéité en glissant un doigt entre votre
sein et l'entonnoir et retirez le tire-lait de votre sein. Mettez le
tire-lait hors tension et débranchez-le. ISIS iQ gardera en mémoire
le rythme et le niveau de succion de vos deux dernières
compressions. Dévissez le gobelet rempli de lait. Si du lait reste
dans le bol de l'entonnoir, videz-le dans le gobelet. Ne remplissez
pas le gobelet à ras bord. Lavez et désinfectez toutes les pièces
avant la prochaine utilisation.
La prochaine utilisation du tire-lait : Poursuivre la séance mémorisée? Mettez le
tire-lait en marche comme à l'étape 1.Terminez l'étape 2. Appuyez sur la touche
de commande bleue qui active le mode automatique. Le tire-lait reproduit les
paramètres gardés en mémoire des deux dernières compressions. Continuez de
pomper tel que décrit à l'étape 4. Vous devez restimuler le réflexe d'éjection? Si vous
devez stimuler le réflexe d'éjection, mettez le tire-lait en marche comme à l'étape 1.
Terminez l'étape 2. Pressez la poignée par petits coups secs et passez à l'étape 3.
Lavez soigneusement vos mains et assurez-vous que vos
seins sont propres.
Allumez le tire-lait : Lorsque le témoin lumineux ORANGE
passe au VERT, le tire-lait est prêt à être utilisé.
Si le témoin lumineux clignote en ROUGE, consultez le « Guide
de dépannage » à la page 43.
Obtenez une bonne étanchéité : Placez fermement le
tire-lait sur le sein, de manière à ce que le mamelon adhère
parfaitement à l'entonnoir. Il ne doit y avoir aucune fuite d'air
entre votre sein et le tire-lait. (Si double-pompage, appuyez
un tire-lait sur chaque sein).
Réflexe d'éjection.Votre corps réagit physiologiquement
au mouvement de succion qu'effectue votre bébé, ce qui
provoque le sein à produire du lait et à l'acheminer vers
le mamelon.
Pour déclencher le réflexe d'éjection, pompez la poignée avec
des petits coups secs. Ce rythme reproduit l'action de votre
bébé lorsqu'il tète. En même temps, vous permettez aux
pétales du coussin masseur
MD
de masser la région sous le
mamelon, stimulant ainsi le réflexe d'éjection. Le lait se met
à couler après quelques pressions; ça ne devrait pas prendre
plus de 5 minutes (consultez la page 29 « Préparation pour
tirer du lait »).Vous pouvez automatiser votre rythme
d'éjection en appuyant sur la touche de commande bleue
ou vous pouvez continuer à pomper manuellement.
Expression du lait : Le lait s'écoule une fois le réflexe
d'éjection enclenché. C'est la phase durant laquelle le bébé
est confortable et prend correctement le sein pour recevoir
le flot dont il a besoin.
Si vous n'avez pas enclenché le pompage automatique, passez
à l'étape 5. Si vous avez automatisé le pompage à l'étape 3,
appuyez sur la touche de commande bleue pour interrompre
le réflexe d'éjection.Vous pouvez maintenant maintenir un
rythme de pompage et une puissance d'extraction adaptés à
votre confort durant toute votre séance.
SUIVEZ LES CONSEILS POUR LA CONSERVATION DU LAIT MATERNEL DES PAGES 41 ET 42.
Tirer du lait avec ISIS iQ DUO
MD
Tirer du lait avec ISIS iQ DUO
MD
Valve blanche
Bol de l'entonnoir
Gobelet réutilisable
Socle (identique à )
Coussin masseur
MD
Protège-entonnoir
(identique à )
Besoin d'aide? Appelez-nous au 1 800.54.AVENT ou visitez www.aventamerica.com
37
Couvercle pour tire-lait
Diaphragme en silicone
avec tige
Poignée fourchue
Lavez et désinfectez toutes les pièces avant chaque utilisation.
Voir section ‘Nettoyer le tire-lait manuel ISIS à la page 37.
38
Vous pouvez utiliser le tire-lait manuel ISIS lorsque vous préférez une option sans fil à
ISIS iQ DUO
MD
. Bien que le tire-lait manuel ISIS partage la plupart des pièces avec ISIS iQ
DUO,veuillez noter que les pièces en vert sont propres au tire-lait manuel ISIS.
Les pièces du tire-lait
manuel ISIS sont dans
un sac séparé.
Nettoyer le tire-lait manuel ISIS
Mise en garde : N'utilisez pas de nettoyants/détergents antibactériens pour nettoyer les pièces
de votre tire-lait
Avant chaque utilisation (y compris la première fois) :
Séparez tous les éléments du tire-lait manuel ISIS et passez-les au lave-vaisselle (dans
le panier supérieur) ou lavez-les à l'eau chaude savonneuse et rincez. Le tire-lait doit
être désinfecté après chaque usage.Toutes les pièces du tire-lait manuel ISIS peuvent
être stérilisées dans un stérilisateur vapeur (électronique, électrique ou à micro-ondes)
ou en les faisant bouillir dans l'eau durant 10 minutes.
1
2
3
4
5
6
Tire-lait manuel ISIS
c
d
e
f
f
g
h
h
u
v
w
u
v
w
c
d
e
f
g
h
Socle blanc
ISIS
MD
Tire-lait manuel – Guide des pièces Assembler le tire-lait manuel ISIS
MD
Lavez vos mains soigneusement. Tenez l'entonnoir
à l'envers et poussez fermement la petite valve
blanche dans la petite ouverture du bol de
l'entonnoir. Assurez-vous que le côté pointu de la
valve est en dessous.
Enfoncez le diaphragme en silicone avec sa tige
dans le bol, les bords bien repliés sur le pourtour.
Pressez les doigts sur toute la circonférence pour
assurer que l'étanchéité est parfaite. (La tâche est
facilitée quand le diaphragme est mouillé.)
Vissez solidement le gobelet réutilisable
sur le bol. Pour plus de stabilité, posez le
gobelet sur le socle.
Insérez le coussin masseur dans l'entonnoir.
Assurez-vous que le coussin masseur
MD
adhère bien
au pourtour de l'entonnoir pour préserver
l'étanchéité. (La tâche est facilitée quand le coussin
masseur est mouillé.)
Glissez la partie fourchue de la poignée sous la
tige du diaphragme et pressez doucement
jusqu'au déclic pour enclencher la poignée.
Cliquez le couvercle sur le bol.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34

Avent ISIS iQ DUO SCF294/21 Manuel utilisateur

Catégorie
Tire-lait
Taper
Manuel utilisateur
Ce manuel convient également à