YORKVILLE PS218P Le manuel du propriétaire

Catégorie
Amplificateur d'instruments de musique
Taper
Le manuel du propriétaire

Ce manuel convient également à

MANUEL DE L'UTILISATEUR
o-ps218p-3v0.pdf
i
INSTRUCTIONS PERTAINING TO A RISK
OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS.
CAUTION:
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO
NOT REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
Read Instructions:
The
Owner’s Manual
should be read and understood
before operation of your unit. Please, save these
instructions for future reference.
Packaging:
Keep the box and packaging materials, in case the unit
needs to be returned for service.
Warning:
When using electric products, basic precautions should
always be followed, including the following:
Power Sources:
Your unit should be connected to a power source only of the
voltage specified in the owners manual or as marked on the unit.
This unit has a polarized plug. Do not use with an extension cord or
receptacle unless the plug can be fully inserted. Precautions should
be taken so that the grounding scheme on the unit is not defeated.
Hazards:
Do not place this product on an unstable cart, stand, tripod, bracket or
table. The product may fall, causing serious personal injury and serious
damage to the product. Use only with cart, stand, tripod, bracket, or table
recommended by the manufacturer or sold with the product. Follow the
manufacturer’s instructions when installing the product and use mounting
accessories recommended by the manufacturer.
The apparatus should not be exposed to dripping or splashing
water; no objects filled with liquids should be placed on the
apparatus.
Terminals marked with the “lightning bolt” are hazardous live;
the external wiring connected to these terminals require installation
by an instructed person or the use of ready made leads or cords.
No naked flame sources, such as lighted candles, should be
placed on the apparatus.
Power Cord:
The AC supply cord should be routed so that it is unlikely that it will
be damaged. If the AC supply cord is damaged
DO NOT
OPERATE THE UNIT
.
Service:
The unit should be serviced only by qualified service personnel.
INSTRUCTIONS RELATIVES AU RISQUE
DE FEU, CHOC ÉLECTRIQUE, OU
BLESSURES AUX PERSONNES.
AVIS:
AFIN DE REDUIRE LES RISQUE DE CHOC ELECTRIQUE,
N’ENLEVEZ PAS LE COUVERT (OU LE PANNEAU
ARRIERE). NE CONTIENT AUCUNE PIECE REPARABLE
PAR L’UTILISATEUR.
CONSULTEZ UN TECHNICIEN QUALIFIE
POUR L’ENTRETIENT.
Veuillez lire le manuel:
Il contient des informations qui devraient êtres comprises avant
l’opération de votre appareil. Conservez S.V.P. ces instructions
pour consultations ultérieures
Emballage:
Conservez la boite au cas ou l’appareil devait être
retourner pour réparation.
Warning:
Attention: Lors de l’utilisation de produits électrique,
assurez-vous d’adhérer à des précautions de bases
incluant celle qui suivent:
Alimentation:
L’appareil ne doit être branché qu’à une source d’alimentation
correspondant au voltage spécifié dans le manuel ou tel qu’indiqué
sur l’appareil. Cet appareil est équipé d’une prise d’alimentation
polarisée. Ne pas utiliser cet appareil avec un cordon de
raccordement à moins qu’il soit possible d’insérer complètement les
trois lames. Des précautions doivent êtres prises afin d’eviter que le
système de mise à la terre de l’appareil ne soit désengagé.
Hazard:
Ne pas placer cet appareil sur un chariot, un support, un trépied ou une
table instables. L’appareil pourrait tomber et blesser quelqu’un ou subir des
dommages importants. Utiliser seulement un chariot, un support, un trépied
ou une table recommandés par le fabricant ou vendus avec le produit.
Suivre les instructions du fabricant pour installer l’appareil et utiliser les
accessoires recommandés par le fabricant.
Il convient de ne pas placer sur l’appareil de sources de flammes
nues, telles que des bougies allumées.
L’appeil ne doit pas être exposé à des égouttements d’eau ou des
éclaboussures et qu’aucun objet rempli de liquide tel que des vases
ne doit être placé sur l’appareil.
Les dispositifs marqués d’une symbole “d’éclair” sont des parties
dangereuses au toucher et que les câblages extérieurs connectés à
ces dispositifs de connection extérieure doivent être effectivés par un
opérateur formé ou en utilisant des cordons déjà préparés.
Cordon d’alimentation:
Évitez d’endommager le cordon d’alimentation.
N’UTILISEZ PAS
L’APPAREIL
si le cordon d’alimentation est endommagé.
Service:
Consultez un technicien qualifié pour l’entretien de votre appareil.
IMPORTANT SAFETY INSTRUCTIONS
SAFE_V4.doc Version 4.0 02/11/99 11:54 AM
1
INTRODUCTION
The PULSE model PS218P is a powered subwoofer with two 300-watt amplifiers, one for each of its dual 18-
inch high-performance woofers. Quick and easy setups are facilitated with features such as a LINE/SPEAKER
push-button which enables you to drive the PS218P's inputs with either line level signal or speaker level
signal, and the inputs will accept either a mono or stereo source. Additionally, the inputs are balanced so that
noise cancellation will be optimized when a balanced line-level source is connected; however an unbalanced
line-level source may also be connected without need for special adjustments or cable adapters.
FEATURES
1. Power Switch, Fuse & LED
The Power Switch and Fuse are located on the
left side of the back panel. Always replace the
fuse with the same type: 8 amp slo-blo (T4A for
230V models).
2. SUBWOOFER LEVEL control
The SUBWOOFER LEVEL control regulates the
PS218P's volume. Set this control for the desired
balance of low frequencies with the rest of your
system. At high operating levels, the subwoofer
power amplifier will be regulated by its limiter.
As a result you may find that increasing the
SUBWOOFER LEVEL control above that
operating level will not have any effect. This is
normal and simply means that maximum
undistorted subwoofer volume has been
achieved. The SUBWOOFER LEVEL control does
not regulate other speakers connected to the
PS218P's PARALLEL THRU jacks.
3. UNGROUNDED/GROUNDED switch
Whenever mixers, AC-powered signal sources
and amplifiers are interconnected there is always
the possibility of a ground loop being created
because something is not grounded the same way
as the rest or because the other connected units
are all ungrounded. Ground loops result in a
continuous 60Hz hum which can be heard
through the speakers. Normally, the PS218P's
ground reference would be lifted with the push-
button in the UNGROUNDED position. If a hum
occurs, try setting the button up in the
GROUNDED position. In the UNGROUNDED
mode, the sleeves of the 1/4-inch inputs are lifted
from ground reference. In the GROUNDED mode,
the grounding is done through a 10-ohm
protection device which prevents damage in case
of accidental cable miswiring.
TIP: The use of balanced cables, even if the line-
level mixer outputs are unbalanced, will help to
reduce the occurrence of hum and noise.
4. INPUT LEVEL push-button
This feature enables you to drive the PS218P's
inputs with either line level or speaker level
signals. For example, if you have connected one of
the INPUT jacks to a mixer's line-level output, you
would push the button up into the LINE position.
If, on the other hand, you have connected the
INPUT/s to one or two speaker outputs on a
mixer/amplifier or power amplifier, or to a parallel
connection on another speaker, you would push
the button down into the SPEAKER position. It is
important for this feature to be set correctly to
ensure proper performance of the product.
2
5. INPUT & PARALLEL THRU Connections
and Balancing
The inputs to the PS218P's dual power amplifiers
are arranged in LEFT and RIGHT parallel pairs.
Internally, the amplifiers share these inputs. In
other words, the signal coming into either of the
INPUT jacks goes to both amplifiers at the same
time (i.e. not separately) and therefore both
speakers are powered. The LEFT/RIGHT INPUT
arrangement simplifies connecting a stereo
source. For example you may simply connect
your left and right stereo amplifier outputs to the
PS218P's INPUT jacks and they will be mixed
down into mono internally to feed the amplifiers.
Meanwhile, the PARALLEL THRU jacks can be
used to feed the stereo signals to another
PS218P's inputs or to a pair of full-range PA
enclosures. On the other hand, if you only have a
mono signal from a mixer or amplifier, or chained
over from another speaker, either one of the
INPUT jacks will do - no need to patch to the
other INPUT jack. The adjacent PARALLEL THRU
jack may then be used to deliver the signal to
another PS218P or, if speaker-level signal is
driving the INPUT jack, to a full-range speaker
enclosure. Additionally, all connectors are
balanced when the push-button is in the LINE
position. The 1/4-inch TRS inputs are wired; tip =
in phase, ring = reverse phase, sleeve = ground
(see under UNGROUNDED/GROUNDED Push-
button re: grounding). Because the input
impedance is very high ( >17k Ohms) any
amplifier driving the PS218P in parallel with
external speakers will not encounter a low load
impedance situation caused by the PS218P. Only
the number and impedance of external speakers
determines the overall impedance.
6. The Power Amplifiers
Both amplifiers are rated at 300 watts into 4
Ohms and feature comprehensive protection
from both thermal and input overloads.
Additionally, they are regulated by full-time
electronic limiting and automatic equalization
(see below). The heatsink fins on the back panel
should be kept well away from walls or anything
which could restrict air flow around them. If the
amplifiers overheat, their output power will be
reduced by the limiter to compensate.
7. Internal Subwoofer Limiter and
Automatic Equalization
In order to achieve maximum utilization of the
subwoofer amplifiers and speakers, the amplifiers
are regulated by a sonically transparent limiter
and an automatic equalization circuit. Together
they respond to a variety of potential situations
including excessive heat and clipping distortion
in the amplifier as well as excessive cone
excursions and even voicecoil overheating in the
speakers. The EQ additionally ensures extended
deep bass down to 45Hz at low to moderate
operating levels and, to protect the woofers at
higher operating levels, bass pre-emphasis is
reduced whenever the limiter cuts in. At very
high limiting levels, the EQ will actually cut the
response below 60Hz to ensure that there will be
no distortion or subwoofer cone damage. This
still permits maximum clean sound pressure in
the above-60Hz range for bass drum kicks.
Note: The PS218P built-in stand mounting adapter can be used with Yorkville SW-Teletube
accessory to support our E160 cabinets. The support tube can be adusted up to it's full 5'4"
extension safely as long as the PS218P is not inclined more than 10°.
WARNING: Larger or heavier cabinets should not be used with the stand mount!
3
CONFIGURATION OPTIONS
4
OPERATION
1. Plug the AC cord into a grounded outlet (120
VAC, 60 Hz in North America, 220-240 VAC, 50
Hz in export models). Switch the PS218P's
POWER switch OFF for now. Make sure that the
back of the PS218P is well clear of walls or
anything which might restrict the flow of cool air
to the heatsinks on the back panel.
2a. If you are using the MAIN, SUBMIX or
another line-level output from your mixer to
drive the PS218P, connect it to one of the INPUT
jacks with a shielded patch cord. Once again we
suggest that you employ balanced shielded patch
cables for line-level connections to the PS218P,
e.g. Yorkville model PC-6ST. Even if the mixer
does not have balanced outputs, you will obtain
some noise cancellation benefits with balanced
lines. If the mixer has stereo line-level outputs,
use two cables going to the LEFT and RIGHT
INPUT jacks. Otherwise either jack will do; there
is no need to patch over to the other INPUT jack
(the gain will be 6dB higher if you energize both
jacks, but a simple LEVEL control adjustment
easily compensates for that).
2b. Set the INPUT LEVEL push-button up in the
LINE position.
2c. If you are connecting the PS218P to the
Speaker output of a mixer/amplifier (or power
amp), or in parallel with a full-range speaker,
plug a speaker cable into one of the 1/4-inch
INPUT connectors. If the amplifier output is
stereo, connect both outputs to the PS218P's
LEFT and RIGHT INPUT jacks.
2d. Set the INPUT LEVEL push-button down in
the SPEAKER position.
3. To interconnect additional PS218P's or other
Yorkville powered speakers, plug one end of the
appropriate type of cable, i.e. shielded or
speaker-type, into the PS218P's PARALLEL THRU
jack nearest the INPUT jack which is in use.
Now connect the other end to the input of the
other unit. Be careful not to connect speaker-
level signals to the input of a powered woofer
which is not designed to take them. And if you
are connecting an additional PS218P or other
Yorkville powered subwoofer this way, make sure
that the other powered subwoofer's push-button
is also in the SPEAKER position.
4. Switch on the POWER, and with music
playing through the system, adjust the PS218P
LEVEL control for the desired mix of subwoofer
and full-range sound. Remember that the
subwoofer volume may not increase greatly at
high settings due to the limiter (see INTERNAL
SUBWOOFER LIMITER and AUTOMATIC
EQUALIZATION in the FEATURES sections).
In Case of feedback
Problem: Low Frequency Feedback with the
Mixer/Amp or Power Amp Shut Down:
The following applies where the PS218P, in
SPEAKER LEVEL mode, and full-range speakers
are interconnected to the PA amplifier and that
amplifier has been switched off, but the PS218P
left on.
With no power available at its inputs from the PA
amplifier, the PS218P can receive random signals
in its PARALLEL THRU jacks generated by the
full-range enclosure's woofers responding to
room sounds (remember, every speaker is like a
dynamic microphone). If the PS218P is powered
up and turned up high, it can see these signals as
input signals and amplify them creating a
possible feedback loop with the full-range
woofers.
Solutions: If you are in the habit of switching
your power off between sets, it is advisable to
switch the PS218P off as well, or turn down its
LEVEL control. Alternatively you might re-wire so
that the PS218P is driven by line-level signals.
Any one of these measures will avoid the above
feedback potential.
5. Should the fuse blow for any reason, replace
with a similar type - 8 amp slo-blo (T4A export).
Repeated blown fuses can be a sign that the AC
line voltage is too high. Try another outlet. If this
fails to solve the problem, take the PS218P to a
qualified technician. DO NOT try to solve the
problem by wrapping metal foil around the fuse.
This can cause considerable damage to this or
any electrical product.
5
Specifications
PS218P
POWERED SUBWOOFER
Power Requirements
North American: 120VAC 60 Hz
300 Watts Typical
European: 230VAC 50 Hz
300 Watts Typical
Power Amplifiers
Power (Internal Amps): 2 x 300 Watts
Input Connections
Inputs: 2 x 1/4" • Outputs: 2 x 1/4"
Tip: Positive, Ring: Negative, Sleeve: Optional
Speakers
2 x 18", 300 Watts each
3" voice coils, high-excursion cones
Performance
Max. S.P.L.: 128 dB
Frequency Response: 40-110 Hz
Limiting
Clipping, Excursion, Average voice coil current.
Grounding
The sleeves of the 1/4" inputs are not grounded except when the GROUND LIFT
pushbutton is set to GND. Then, grounding is through a 10 Ohm protection
device in order to prevent damage due to accidental miswiring.
Weight:
176 lbs. (80 kg.)
Dimensions
(HxWxD): 40.5" x 26.0" x 26.0"
102.9 x 66.0 x 66.0 cm
6
INTRODUCTION
Le subwoofer amplifié compacte PULSE PS218P est doté de deux amplificateurs de 300 watts. Un pour
chaque woofers de haute performance de 18". Les entrées acceptent des signaux stéréo ou mono et le
bouton poussoir LIGNE / HAUT-PARLEUR permet un assemblage facile et rapide en offrant l'option
d'utiliser votre PS218P avec un signal de niveau DE LIGNE ou avec un signal de niveau HAUT-PARLEUR.
Les entrées sont équilibrées pour offrir un rapport signal/bruit optimum avec une source équilibrée de
niveau ligne; une source de signal déséquilibré niveau ligne peut cependant être reliée sans avoir à
requérir à des ajustements spéciaux ou à des adaptateurs.
FEATURES
1. INTERRUPTEUR GÉNÉRAL,
FUSIBLE ET DEL
Le FUSIBLE et l'interrupteur général sont situés sur
le côté gauche du panneau arrière. Remplacez
toujours le fusible avec un du même type - 8-amp à
action retardée en Amérique du Nord (T4A pour
modèle à 230V).
2. CONTRÔLE DE NIVEAU
POUR SUBWOOFER
Le contrôle DE NIVEAU SUBWOOFER règle le
volume du PS218P (dB). Réglez ce contrôle de façon
à obtenir la balance désiré entre le subwoofer et le
système pleine - gamme. À des niveaux d'opération
élevés, le niveau du subwoofer sera contrôlé par un
limiteur interne. L'augmentation du contrôle bien au-
dessus de 0dB aura par conséquent un effet limité sur
le volume réel du SUBWOOFER. Cela signifie
simplement que vous avez atteint le niveau maximum
de signal, sans distorsion, pour le subwoofer.
3. BOUTON POUSSOIR de raccordement
à la masse "GROUND LIFT/GROUND"
Lorsqu'une sources de signal sous tension, est
branchée à un amplificateurs, il y a toujours la
possibilité de la création d'une boucle de masse
(ground loop). Cela est normalement causé par un
appareil doté d'un dispositif de branchement à la
masse qui n'est pas comme les autres, ou parce que
les autres unités dans la chaîne ne sont pas du tout
branchées à la masse. Le résultat: un
bourdonnement continu de 60-Hz qui peut être
entendu par l'entremise des haut-parleurs. Le
bouton poussoir "GROUND LIFT / GROUND" du
PS218P devrait normalement être en position
"UNGROUNDED". Si un bourdonnement survient,
essayez le commutateur en position "GROUNDED".
En mode "UNGROUNDED", les manchons des
prises d'entrées 1/4" sont débranchées de la masse.
En mode "GROUNDED", le branchement à la masse
est accomplit par l'entremise d'un dispositif de
protection 10 Ohm qui empêche le dommages
causés par un câblage incorrect.
Note: L'utilisation de câbles symétriques, même
lorsque les sorties de la source sont asymétriques,
aidera à réduire le niveau de bruit et bourdonnement.
4. BOUTON POUSSOIR "LINE/SPEAKER"
Cette caractéristique vous permet d'alimenter les
entrées du PS218P avec des signaux de niveau ligne
ou de niveau H.P. Par exemple, si vous avez relié la
SORTIE PRINCIPAL d'un mixeur (niveau ligne) à
une des entrées du PS218P, vous devez régler le
bouton en position "LINE". Si, par contre, vous avez
relié un raccordement parallèle à partir d'un autre
7
haut-parleur lui même alimenté par un mixeur /
amplificateur ou un amplificateur de puissance,
vous devez régler le bouton en position
"SPEAKER". Il est important de régler ce sélecteur
correctement pour assurer la performance
optimum de votre PS218P.
5. PRISES D'ENTRÉES PARALLÈLES
Le PS218P est muni de deux pairs d'entrées, une
pair pour. Ces entrées sont partagées par les deux
amplificateurs internes. Autrement dit, le signal
présent à n'importe qu'elle des prises d'entrées
sera acheminé aux deux amplificateurs
simultanément ( il n'y a pas de prises d'entrée
spécifique à chaque amplificateurs).
L'arrangement gauche et droit a été conçu pour
simplifier le branchement d'une source stéréo.
Vous pouvez par exemple simplement brancher
les sorties gauche et droite de votre amplificateur
stéréo et les deux seront mélangé intérieurement
en un signal mono qui sera acheminé aux
amplificateurs internes. Les jacks "PARALLEL
THRU" permettent de ensuite acheminer les
signaux vers un autre PS218P ou des enceinte
pleine gamme. D'un autre coté, si la source est
mono, vous pouvez utiliser n'importe quel jacks
d'entrée du PS218P. Il n'est pas nécessaire
d'amener le signal à l'autre jack d'entrée avec un
câble. Le jack "PARALLEL THRU" adjacent peut
être utilisé pour acheminer le signal à un autre
PS218P ou si un signal de niveau haut-parleur est
utilisé, à un enceinte pleine gamme. Les entrées
sont toutes équilibrées quand le sélecteur est en
position "LINE". Les entrées 1/4" sont branchées
selon les normes TRS (Pointe - bague -Manchon).
> Pointe = 0° phase (positive) Anneau = 180°
phase (contraire) Manche = masse. (voir 5.
BOUTON POUSSOIR de raccordement à la
masse "GROUND LIFT/GROUND" en ce qui
concerne le branchement à la masse).
L'impédance d'entrée est très élevée (>17k-
ohms). La sortie d'un amplificateur de puissance
peut donc être branchée sans problème au
PS218P en parallèle avec des enceintes pleine
gamme sans présenter une charge d'impédance
trop basse. L'impédance sera donc déterminé par
l'impédance de l'enceinte pleine gamme.
6 LES AMPLIFICATEURS
La puissance des deux amplificateurs est estimés
à 300 watts chacun en mode 4-ohms. Ces
amplificateurs possèdent de plus des
caractéristiques de protection considérable pour
les surcharges thermiques et les niveaux d'entrées
survoltés. Les amplificateurs sont également
constamment régulés par un limiteur interne
électronique et l'égalisation automatique (voir la
section ci-dessous). Les ailerons du déchargeur
thermique de l'amplificateur sont situés au
panneau arrière. Ils devraient être gardés bien
loin des murs ou toute autres obstruction qui
pourrait limiter la circulation d'air nécessaire
pour le refroidissement de l'appareil. Si
l'amplificateur du subwoofer surchauffe, son
pouvoir de rendement sera réduit par le limiteur
pour compenser.
7. LIMITEUR / EGALISATION
Un limiteur transparent et un circuit d'égalisation
automatique permettent une utilisation maximale
de l'amplificateur de puissance pour subwoofer
et de ses subwoofers. Ensemble, ils répondent à
une variété de risques potentiels incluant la
chaleur excessive et la distorsion au niveau de
l'amplificateur; Ils répondent aussi aux
excursions excessives de cône de haut-parleur et
même à la surchauffe de la bobine mobile de
haut-parleur. L'égalisateur assure également une
réponse prolongée des basse profonde jusqu'à
45Hz lors de l'opération à des niveaux bas ou
modérés. La protection des woofers lors de
l'opération à des niveaux élevés est assuré par
l'intervention du limiteur qui réduit
l'accentuation des basses fréquences. À des
niveaux très élevés, l'égalisateur coupera la
réponse en dessous 60Hz pour assurer un signal
sans aucune distorsion ou pour éviter
l'endommagement du cône de subwoofer. Cela
permet d'obtenir des niveaux de pression sonore
pour les fréquences au dessus de 60Hz (pour les
coups de grosse caisse).
NOTEZ BIEN: L'adapteur de support encastré au PS218P peut être utilisé avec l'accessoire
YORKVILLE SW-Teletube pour supporter les enceintes E160. Le tube de support peut être
ajusté à sa pleine extension de 5'4" (en toute) sécurité quand le PS218P est incliné à moin de
10° par rapport à l'horizontale.
ATTENTION: Les enceintes plus larges où plus lourdes ne doivent pas être utilisé avec
l'adapteur de support encastré.
8
ENCEINTE
PLEINE GAMME
ENCEINTE
PLEINE GAMME
ENCEINTE
PLEINE GAMME
ENCEINTE
PLEINE GAMME
ENCEINTE
PLEINE GAMME
ENCEINTE
PLEINE GAMME
ENCEINTE
PLEINE GAMME
ENCEINTE
PLEINE GAMME
ENCEINTE
PLEINE GAMME
ENCEINTE
PLEINE GAMME
SOURCE DE NIVEAU LIGNE AU SUBWOOFER
DEUX SUBWOOFERS PAR SYSTÈME
PROCESSOR ÉLECTRONIQUE AVEC ENCIENTES
PLEINE GAMME STEREO ET UN SUBWOOFER
ENCIENTE PLEINE GAMME MONO ET UN SUBWOOFER
UN SUBWOOFER PAR SYSTÈME
AMPLIFICATEUR
DE PUISSANCE
AMPLIFICATEUR
DE PUISSANCE
AMPLIFICATEUR
DE PUISSANCE
MONO
AMPLIFICATEUR
DE PUISSANCE
AMPLIFICATEUR
DE PUISSANCE
ENTRÉE AU
PROCESSOR
PROCESSOR ÉLECTRONIQUE
SOURCE DE
NIVEAU LIGNE
OPTIONS DE CONFIGURATION
9
OPERATION
1. Branchez le cordon d'alimentation AC à un
réceptacle avec branchement à la masse.(120
VCA, 60 Hz en Amérique du Nord, 220-240
VCA, 50 Hz pour models d'exportation).
Gardez pour l'instant l'alimentation en
position "OFF". Assurez-vous que l'arrière du
PS218P est bien éloigné des murs ou de
n'importe quoi qui pourrait empêcher une
bonne circulation d'air au dissipateur de
chaleur au panneau arrière.
2a. Si vous utilisez la sortie MAIN, SUBMIX ou
autre sortie niveau ligne de votre mixeur pour
acheminer le signal au PS218P, utilisez un câble
blindé branché au jack d'entrée du PS218P.
encore une fois, nous vous conseillons d'utiliser
des câbles blindés symétrique pour les
branchement niveau ligne. Par exemple le model
PC-6T de Yorkville. Même si le mixeur n'est pas
équipé de sortie symétrique, vous obtiendrez en
partie, les résultats d'annulation de bruit
normalement associé au système symétrique en
utilisant des câble blindés symétrique. Si le
mixeur est équipé de sortie ligne stéréo, utilisez
deux câbles, un pour le coté droit et un pour le
gauche. Sinon, vous pouvez utiliser n'importe
quel jack d'entrée; Il n'est pas nécessaire
d'amener le signal à l'autre jack d'entrée avec un
câble ( vos obtiendrez un gain plus élevé de 6 dB
si les deux jack sont utilisé. Vous pouvez
compenser avec un simple ajustement du
contrôle de volume).
2b. Réglez le bouton INPUT LEVEL en
position "LINE".
2c. Si vous branchez le PS218P à la sortie
"speaker" de votre mixeur ( ou amplificateur de
puissance), ou en parallèle avec un enceinte
pleine bande, branchez le câble pour H.P. dans
un des jacks d'entrée. Si l'amplificateur est doté
de sortie "speaker" stéréo, branchez les deux
aux jack d'entrée gauche et droit du PS218P.
2d. Réglez le bouton INPUT LEVEL en
position "SPEAKER".
3. Pour brancher des PS218P ou autre enceinte
amplifié additionnel, branchez une des extrémité
d'un câble de type approprié (blindé ou pour
H.P.) au jack "PARALLEL THRU" le plus près de
la prise d'entrée qui est utilisé. Branchez ensuite
l'autre extrémité au jack d'entrée de l'autre
enceinte. Assurez-vous de ne pas brancher un
signal de niveau haut-parleur à l'entrée d'un
enceinte qui n'as pas été conçue pour
fonctionner avec un tel signal. Si vous branchez
un sub additionnel PS218P, ou autre enceinte
amplifier Yorkville, assurez-vous que le bouton
INPUT LEVEL est en position "SPEAKER".
4. Mettez l'appareil en marche et avec de la
musique, ajustez le niveau du PS218P (avec son
contrôle "LEVEL" de façon à obtenir le mélange
désirée de sub/pleine bande. Rappelez-vous que
le volume du subwoofer n'augmentera pas
beaucoup à des réglages élevé ceci due au
limiteur. (voir la section LIMITEUR INTERNE &
EGALISATION AUTOMATIQUE POUR
SUBWOOFER).
5. Si pour quelque raison que ce soit, le fusible
brûle, remplacez le avec un du type semblable -
8 amp slo-blo (T4A sur model d'exportation). Un
fusible qui brûle à plusieurs reprise peut indiquer
une ligne de voltage trop élevé. Essayez une
autre prise de courant. Si le problème n'est pas
résout de cette façon, apportez votre PS218P à
un technicien qualifié. N'essayez surtout pas de
régler le problème en enrobant le fusible avec un
papier d'aluminium. Vous pourriez ainsi causer
des dommages considérables au PS218P ou à
n'importe quel autre appareil électrique.
En cas de feedback
Feedback de basse fréquence avec mixeur
amplifiée ou amplificateur de puissance éteint.
Ce qui suit s'applique dans les cas ou le
PS218P, en mode "speaker level", et les
enceintes pleine bande sont branchées à
l'amplificateur et que cet amplificateur est
éteint mais le PS218P est en marche.
Sans signal provenant de l'amplificateur de signal
présent à l'entrée, le PS218P peut recevoir des
signaux aléatoires au jack "PARALLEL THRU".
Ces signaux sont généré par les H.P. des
enceintes pleine bande. Dans ce cas, les H.P.
répondent aux sons de la pièce (rappelez-vous,
les haut-parleurs et les microphones dynamiques
sont semblables). Si le PS218P est en marche et
que sont volume est élevé, il peut interpréter ses
signaux comme signaux d'entrée et les amplifier
créant ainsi la possibilité d'une boucle de
feedback avec l'enceinte pleine bandes.
Solutions: Si vous avez l'habitude d'éteindre
votre amplificateur durant les intermissions, nous
vous conseillions d'éteindre aussi votre PS218P
ou réduire son volume. Vous pouvez aussi refaire
les branchement pour amener au PS218P un
signal de niveau ligne. Ces deux méthodes vous
permettrons d'éliminer les chance de feedback.
10
Specifications
Puissance requise
amérique du nord: 120VAC 60 Hz
300 Watts Maximum
europe: 230VAC 50 Hz
300 Watts Maximum
Amplificateur
puissance (interne): 600 Watts
impédance d'entrée: 80 kOhms ou plus
Haut-parleurs
2 x 18", 600 Watts (total)
3" voice coils, high-excursion cones
Performance
Max. S.P.L.: 128 dB
Frequency Response: 40-110 Hz
Raccordements d'Entrée
Entrées: 2 x 1/4", Sorties: 2 x 1/4"
Pointe: Positif, Bague: Negatif, Manchon: Optionnel
Mise à la terre
Les manchons des entrées ne sont pas raccordés à la masse sauf quand le
commutateur de mise à la terre d'entrée est réglé à la position "GND." La mise à
la terre est effectuée par un dispositif de protection de 100 ohms de façon à
empêcher les dommages causés par une erreur de branchement.
Limiteur
écrêtage, excursion et moyenne du courant à la bobine mobile
Poids
176 lbs. (80 kg.)
Dimensions
(HxLxP): 40.5" x 26.0" x 26.0"
102.9 x 66.0 x 66.0 cm
PS218P
POWERED SUBWOOFER
11
Notes
U.S.A.
Yorkville Sound Inc.
4625 Witmer Industrial Estate
Niagara Falls, New York
14305 USA
Voice: (716) 297-2920
Fax: (716) 297-3689
WORLD HEADQUARTERS
CANADA
Yorkville Sound
550 Granite Court
Pickering, Ontario
L1W-3Y8 CANADA
Voice: (905) 837-8481
Fax: (905) 837-8746
Quality and Innovation Since 1963
Printed in Canada
WEB: www.yorkville.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

YORKVILLE PS218P Le manuel du propriétaire

Catégorie
Amplificateur d'instruments de musique
Taper
Le manuel du propriétaire
Ce manuel convient également à

dans d''autres langues