Fedders AEY18F7G*H Le manuel du propriétaire

Catégorie
Climatiseurs split-system
Taper
Le manuel du propriétaire

Ce manuel convient également à

Model No., No. de Modelo, N° de modèle
Serial No., No. de Serie, N° de série
Date of Purchase, Fecha de Compra, Date d’achat
For Future Reference
Write down the model and serial numbers
The model and serial numbers can be found on the side of the
cabinet near the control panel. Use these numbers in any
correspondence or service calls concerning your air
conditioner.
Para referencia futura
Escriba el número de modelo y de serie
El número de modelo y de serie se encuentran en el costado
del gabinete cerca del panel de control. Use estos números en
toda la correspondencia o llamadas de servicio relacionadas
con su acondicionador de aire.
Pour consultation ultérieure
Inscrivez les numéros de modèle et de série
Noter ci-contre les numéros de modèle et de série (on les
trouve sur le côté de la grille décorative avant, près du tableau
de commande). Communiquer ces numéros lors de toute
correspondance ou appel au service après-vente ayant trait au
climatiseur.
ENGLISH
Important Safety Instructions .................................. 2
Installation
Window installation .............................................. 3
Thru the wall installation ...................................... 5
Operation
Electronic controls ................................................ 6
Cleaning the air filter ..............................................7
Service/Troubleshooting .......................................... 8
Warranty.................................................................. 9
ESPAÑOL
Instrucciones importantes de seguridad ................ 10
Instalación
Instalación en la ventana .................................... 11
Instalación empotrado en la pared ...................... 13
Funcionamiento
Controles electronicos ...................................... 14
Limpieza del filtro del aire.................................. 16
Servicio/Localización y Solución de averías .......... 17
Garantía ................................................................ 18
FRANÇAIS
Directives de sécurité important .......................... 19
Installation
Installation dans une fenêtre .............................. 20
Installation à travers un mur ................................ 21
Utilisation
Commandes électronique .................................. 23
Nettoyage du filtre à air ...................................... 25
Dépannage/Guide de diagnostic............................ 26
Garantie ................................................................ 27
Room air conditioners for
double hung windows &
through-the-wall installation
Acondicionadores de aire para
ventanas de guillotina y
empotrados en la pared
Climatiseurs – Installation dans
un mur ou une fenêtre à
guillotine
2
ELECTRICAL REQUIREMENTS
& SAFETY PRECAUTIONS
IMPORTANT
WARNING
WARNING
Do not remove or modify this plug
Do not use as an on/off switch
Do not use outdoors
Do not push furniture against or place
furniture on the electrical cord. This can trip
the test switch and/or damage the cord and
become a potential condition for arcing
Do not attempt to repair the cord. If the cord
requires replacement, call an authorized
servicer.
The Arc Detection Device is not a Ground
Fault Interrupter and should not be used as
such
The Arc Detection Device contains an
electronic circuit board and should not be
submerged or exposed to water spray
Resetting
If the Arc Detection Device has tripped, the
reset button will pop up.
Follow these steps to reset the Arc Detection
Device:
1. Unplug unit from electrical outlet
2. Press the reset button
3. Plug the unit back into electrical outlet
4. Check to see if power has returned to the
unit
Testing
You should test the Arc Detection Device
equipped power cord monthly, after every
major electrical storm, or if power to your
Room Air Conditioner has been interrupted.
Follow these steps to test the Arc Detection
Device:
1. Unplug unit from electrical outlet
2. Press the reset button
3. Plug the unit back into electrical outlet
4. Press test button. Unit should trip and reset
button will pop up.
5. Press reset button again for use
If above test fails, stop using the air
conditioner and contact customer service
by calling the following toll-free number:
1-800-332-6658
Power Cord with
Arc Detection Device
The power cord supplied with this air
conditioner is equipped with an Arc
Detection Device designed to shut off power
to the unit when it senses an arc fault
condition. An arc fault is an unintentional
electrical discharge that occurs when
electrical products or wires are damaged,
aged, or improperly used. An arc fault can be
potentially hazardous if left undetected.
Electrical Shock Hazard
Plug unit only into a grounded
electrical outlet.
Do not use an extension cord or plug
adapter with this unit.
Do not operate unit with decorative front
or filter removed.
Failure to follow these precautions could
result in electrical shock, fire or personal
injury.
If the air conditioner has a serial plate
rating of 115 volts and greater than 7.5
amps, it must have its own fuse or circuit
breaker, and no other device or unit
should be operated on that fuse or circuit
breaker.
If the air conditioner has a serial plate
rating of 230 volts, it must have its own
fuse or circuit breaker, and no other
device or unit should be operated on that
fuse or circuit breaker.
We recommend that a qualified
electrician install unit in accordance with
the National Electrical Code and local
codes and ordinances.
Use copper conductors of correct wire
gauge and protector size only.
Do not alter cord or plug end. Do not
remove warning label on cord.
Important Grounding Requirements
Air conditioner has a three-prong
grounding plug on the power supply cord,
which must be plugged into a properly
grounded three-prong wall receptacle for
your protection against possible shock
hazard. For models up to and including
7.5 amperes, use a grounding type wall
receptacle to match the cord plug.
For models above 7.5 amperes use a
single outlet grounding type wall
receptacle to match the cord plug.
Additional Safety Precautions
Do not cut, alter or remove any of the
expanded polystyrene (styrofoam)
inside this air conditioner.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
The fumes can create a fire hazard or
explosion.
Do not introduce objects in the air
discharge area. This could cause
permanent damage.
Do not pour liquids on the air
conditioner as this could cause a
malfunction. With the unit unplugged,
use a damp cloth for cleaning the unit.
Do not use strong solvents to clean
the air conditioner.
• Clean the air conditioner filter every
two weeks to avoid overheating
caused by air obstruction. Do not
operate without filter.
Do not obstruct the air intake area of
your air conditioner, as this could
cause overheating, thus activating the
unit’s security switch and shutting off
the unit.
Do not block air circulation to outside
louvers of cabinet.
Do not block air flow inside with
blinds, curtains, or furniture, or
outside with shrubs, enclosures, or
other buildings.
Do not run the air conditioner with an
outside protective cover in place. This
could result in fire or mechanical
damage within the air conditioner.
250V
30A
250V
15A
125V
15A
250V
20A
Warning
Do not operate this air conditioner without
proper time delay circuit protection
(circuit breaker or fuse). Refer to serial
plate for proper power supply
requirements.
Recommended Wire Sizes
(As installed per building code) :
PROTECTOR SIZE WIRE GAUGE
15 AMP #14 MINIMUM
20 AMP #12 MINIMUM
30 AMP #10 MINIMUM
Installation Parts Kit contents:
3
WINDOW INSTALLATON
INSTALLATION
Decorative Front Removal
1. Remove the 3/8” phillips screws on either side of the cabinet.
2. Gently pull forward while grasping both sides of the decorative front.
Removing the Chassis
1. Remove the two (2) shipping screws from the rear bottom side of the
cabinet. These shipping screws may be discarded.
2. Remove the two (2) anti-theft screws from the bottom front sides of
the cabinet. RETAIN THESE SCREWS, they will be replaced later in
the installation.
3. Slide the chassis out of the cabinet by grasping the base pan handle
and pulling forward while bracing the top bar.
Tools Needed
23 7/8” to 41 5/8”
Screwdrivers
Ratchet or Driver with 1/4” socket
Tape Measure
Carpenters Level
A
B
C
A
A
D
A
B
C
D
E
E
Window Requirements:
This air conditioner is factory prepared for installation in standard double-
hung windows with actual opening width of 26 7/8” to 41 5/8” and clear,
vertical opening of 15 5/8” minimum from bottom of sash to sill. Unit can
be installed in 23 7/8” wide window, if cabinet side seals are removed.
Cabinet
Decorative front
3/8” Phillips screw
A
B
B
A
B
B
C
C
C
Top Bar
Filler panel frame
Filler panel locking edge
A
B
C
Filler Panel Frame Installation
1. Slide the filler panel frame onto the air conditioner cabinet using the
tracks on the top bar and bottom bar of the unit. Slide the frame as close
to the air conditioner as possible so that the curtain locks into place.
2. Gently pull the frame out until it is the correct length for your
application.
Use caution when working around exposed sharp edges
of the cabinet and sharp coils to avoid injury or torn
clothing.
Fastener Identification
Actual size
Item
Description
1” wood screw
5/8” wood screw
Qty
1
5
A
B
A B
15 5/8” minimum
Shipping screws
Cabinet
Anti-theft screws
Chassis
Base pan handle
A
B
C
D
E
Bottom bar
Cabinet
D
E
Before you start:
Window Installation
Carpenters level
Window sash
Filler panel
5/8” wood screw
Window sill
WINDOW INSTALLATON
INSTALLATION
4
1. Open window, by raising lower window sash, and mark
the center of window sill. Carefully place cabinet in
window and align center hole on the bottom bar with the
center mark on the window sill.
2. Close lower window sash until it touches behind the top
bar. (Do not release your grip on the cabinet until the
lower window sash is in its final position).
3. Attach the cabinet to the window sill by driving one 1” long
wood screw through the bottom bar into the window sill.
Be sure cabinet maintains an downward pitch. Air
conditioner should slant slightly downward on the
outside as shown by 1/2 a bubble off on a carpenters
level. This outward pitch prevents water from entering the
room.
Securing the Filler Panels
1. Slide filler panels outward until they touch window sash
tracks.
2. Secure top of filler panels by driving a 5/8” wood screw
through each top mounting hole into window sash.
3. Secure bottom of filler panels by driving a 5/8” wood
screw into window sill through each filler panel tab.
4. Install chassis into cabinet.
Installing the Chassis into the Cabinet
1. Slide the chassis into the cabinet.
2. Replace the two anti-theft screws at the bottom front sides
of cabinet.
3. To replace the decorative front, line up the top tabs and
sides, and gently press into position. Reattach the screws
on both sides of the decorative front. Make sure the
power cord aligns with the power cord slot on the bottom
of the decorative front. Make sure the decorative front is
secure before reconnecting the plug and operating the
unit.
4. Cut plastic foam seal to width of window and install
between upper and lower window sash.
5. Use latex or silicone sealant (not supplied) to fill any
minor openings.
Window sill
Bottom bar
1” Wood screw
A
B
C
D
D
E
E
Foam seal
Lower sash
Filler panel
Molding
Window Sill
Anti-theft screw
Chassis
Dec front
A
D
C
B
E
H
G
F
A
A
B
B
C
C
A
B
C
D
E
F
G
H
A
D
C
B
Do not drill a hole in the bottom pan. Unit is
designed to operate with approximately 1/2” of
water in bottom pan.
Do not obstruct the air intake area of your air conditioner,
as this could cause overheating, thus activating the unit’s
security switch and shutting off the unit. Do not block
aiflow inside with blinds, curtains, or furniture. Do not
block airflow outside with shrubs, enclosures, or other
buildings.
Side view
Window Installation
(cont.)
5
THRU-WALL INSTALLATION
INSTALLATION
Installing Cabinet in
Minimum Width Window
1. Remove filler panels on air conditioner cabinet.
2. Refer to steps 1 through 3 of Window Installation instructions.
3. Close window until it touches behind air conditioner top bar.
4. Fasten top bar to window frame using 5/8” washer head screw.
5. If filler is required on sides of air conditioner, cut plastic foam seal
to size and fill both sides.
6. Use silicone or latex sealant (not supplied) to fill any minor openings.
7. Install chassis into cabinet.
Consult your authorized dealer or importer for alternative
installation instructions.
Top bar Attach top bar here
A
A
B
B
Through-the-wall Installation
This air conditioner is designed as a slide-out type chassis, making it
possible to install it through-the-wall in both existing and new
construction. We recommend that this type of installation be performed
with professional assistance.
• IMPORTANT:
This appliance must be installed according to all
applicable electrical and building codes and ordinances.
It is recommended that you have help to install your unit and that you
use proper lifting technique to avoid personal injury.
It is important that you inspect the condition of the wall where the air
conditioner will be installed.
Be sure the wall can support the weight of the unit.
All cabinet louvers MUST BE on the outdoor side of the wall. DO NOT
BLOCK SIDE LOUVERS.
The cabinet must be installed level from side-to-side and with a
downward tilt from inside to outside.
1. First remove the decorative front panel and chassis from the cabinet,
then remove top bar from the cabinet.
2. Determine the size of the opening for a wood frame by adding 1/8”
to the width and height of the cabinet. Measure height from top of
cabinet to bottom of bar. Add this measurement to the thickness of
wood used to build the frame. This will determine the size of wall
opening needed. Minimum 1” thick lumber is recommended when
building the frame. When determining finish frame thickness, be sure
not to cover side louvers on the cabinet.
3. Install the finished frame in the wall opening square and level, nail
or screw it securely to the wall and place the cabinet into the framed
wall opening.
4. Make sure cabinet projects into the roomside of the wall 1 1/4” at
the top and 1 1/2” at the bottom to ensure proper tilt and access to
the anti-theft screw, then fasten cabinet to the frame by drilling
twelve (12) 1” wood screws (not supplied) through the cabinet and
into the frame. (Fig. 1 &2)
If installation is made in a building with brick veneer construction, a
steel angle lintel must be used to support the bricks above the
cabinet.(Fig.3)
5. Install a 3/4” X 1 1/2” wood filler strip between the bottom bar and
the interior, caulk both top and bottom of this strip. After cabinet is
installed, caulk all openings, inside and outside, between finish
frame and cabinet to prevent moisture from getting to the interior of
the wall. Use of flashing (driprail) will further prevent water from
dripping inside the wall.
6. Install chassis into cabinet.
A
J
J
K
L
M
N
M
M
P
P
E
C
D
D
B
G
H
F
O
O
I
I
Wood frame
1” wood screws
Cabinet
Bottom bar
Interior wall
Decorative front
Minimum 1x6 wood
support (nailed or
screwed to wood
frame)
2” Wood frame
1 1/2” space
1 1/4” space
Brick veneer
Lintel angle
Caulking
Flashing (drip rail)
Side louvers
Wood filler strip
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Fig. 1
Fig. 2
Fig. 3
6
OPERATION
ELECTRONIC CONTROLS
Power Control
The Power Control turns the unit on and off.
Set Temperature/ Timer Display
Shows the set temperature when the unit is in operation and hours when the timer is being
set. THE TEMPERATURE DISPLAY ONLY SHOWS THE SET TEMPERATURE, NOT THE
ACTUAL ROOM TEMPERATURE.
Temperature/ Timer Hour Controls
These buttons are used to raise or lower the set temperature in increments of 1° from 66°F to
88°F. By depressing both buttons at once, the display will toggle between Celsius and
Fahrenheit. When the timer is being set, these buttons are used to change the hour setting in
increments of 1 from 00 to 24.
Mode Control
A green light will indicate which mode is currently being utilized.
Cool Mode –
The unit will circulate and cool the air.
Heat Mode (Heat Models Only)
The unit will circulate and heat the air.
Heater Safety Feature- When heater is powered off, low fan will automatically stay on and run for 60
seconds to ensure the removal of residual heat, meanwhile, the Low Fan LED blinks until the low fan
stops.
Fan Mode –
The unit will only circulate the air.
Energy Saver Mode –
(The energy saver mode is designed to operate with Cool mode only). The fan will switch from
the set fan speed to Low whenever the compressor turns off in response to the thermostat.
When the compressor cycles back on, the unit will return to the original fan setting. Speeds
will change automatically as the temperature in the room changes.
Fan Speed Control - High, Medium, Low and Auto
The settings are adjusted with the Fan Speed Control, each time the button is depressed it
changes the setting. A green light will indicate which setting is currently being used.
When the Auto feature is selected while the air conditioner is in the Cool or Heat mode, the
fan speeds will change automatically as the temperature in the room changes. In Cool Mode
when the room reaches 7° or more above the set temperature High Fan will be used, 4° or
less above the set temperature will use Low fan. In Heat Mode when the room reaches 7° or
more below the set temperature High fan will be used, 4° or less below the set temperature
will use Low fan. At all other times the fan will use Medium fan.
Timer Control (The timer can be set to either turn the unit on or off.)
To automatically START the unit using the Timer mode:
1. Push the timer button while the power is OFF. The display will read 00. Adjust the display
to show the desired number of hours before START-UP using the Temperature/Timer
adjustment arrows.
2. The display will show the amount of time, in hours, remaining until START-UP.
3. To exit Timer mode, push the Timer button.
4. A green light next to the Timer button indicates that the timer is set.
To automatically SHUT-DOWN the unit using the Timer mode:
1. Push the timer button while the power is ON. The display will read 00. Adjust the
display to show the desired number of hours before SHUT-DOWN using the
Temperature/Timer adjustment arrows. (The display will automatically return to the set
temperature after 10 seconds.)
2. To display the amount of time left until SHUT-DOWN, push the Timer button once.
3. To exit Timer mode, push the Timer button twice.
4. A green light next to the Timer button indicates that the timer is set.
A
B
C
D
E
F
Electronic Control (Cooling Only)
Built in Three Minute Cooling Delay
Cool
High
Timer
Med
Auto
Low
Fan
Energy Save
Heat
On/Off
A
B
C
C
D
D
E
E
F
F
Temperature/Timer Display
Temperature/Timer Adjustment
Timer On/Off
Fan Speed Control
Mode Control
Power Control
A
B
Electronic Control (Heat/Cool)
Built-in three minute timing delay.
If this electronic unit will not respond to touch
pad or remote control commands, it is
necessary to unplug the unit from the electrical
outlet for five seconds and then plug the unit
back in.
Auto restart feature:
In the event of a power failure, this
feature allows the unit to resume
operation once power has been restored,
retaining the most recent settings. Upon
restoration of power, the timer mode may
need to be reset if being utilized.
CAUTION
Heat/Cool models or units with
electric heat are designed to be
used only as a supplemental heat
source.They should be used in
addition to regular heating systems
and never as the primary source of
heat.
OPERATION
REMOTE / AIR FILTER
7
Filter
Louvers
Vent door
A
C
C
B
A
B
Directing Airflow
Unit is engineered with adjustable louvers to direct discharge airflow.
Louvers are manually adjusted by moving levers in direction of
desired airflow.
Cleaning the Air Filter
Clean the filter every two weeks
1. Turn Master Control to OFF.
2. Remove the air filter by opening the air intake panel on the
decorative front and pull it out of the unit.
3. Wash in hot soapy water, rinse and shake dry.
4. Replace the filter, with the front of the filter toward you.
5. To dry the filter thoroughly, run your unit for a few minutes.
Remember, only a clean filter works properly and delivers top
efficiency at every setting.
Note: Failure to keep air filter clean will result in poor air
circulation. DO NOT operate without filter. This can render the unit
inoperative.
Proper use and care of your air conditioner will help ensure longer
life of the unit. It is recommended to annually inspect and clean the
coils and condensate water passages. Expense of annual inspection
is the consumer’s responsibility.
The functions work the same as your air conditioners touch controls.
Air Conditioner Remote Control
Remove the back cover
and insert the batteries
with the poles (+) and (-)
in the correct position.
CAUTION
• Use only AAA or IEC R03 1.5V batteries.
• Remove the batteries if the remote controller is not used for a
month or longer.
• Do not attempt to recharge the supplied batteries
• All batteries should be replaced at the same time.
• Do not dispose of the batteries in a fire as they may explode.
• Do not mix old and new batteries.
• Do not mix alkaline, standard (carbon - zinc), or rechargeable
(nickel-cadmium) batteries.
• Do not install the batteries with the polarity (+/–) reversed.
• Keep batteries and other things that could be swallowed away
from young children. Contact a doctor immediately if an object is
swallowed.
SERVICE
TROUBLESHOOTING
8
Occurrence Possible Cause Solutions
Air conditioner will not operate • Wall plug disconnected. Push plug firmly into wall outlet.
• House fuse blown or circuit breaker tripped. Replace fuse with time delay type
or reset circuit breaker.
• Power switch in OFF position. Turn power switch to ON position.
• Unit accidentally turned off by moving the Wait approximately 3 minutes.
thermostat to a higher temperature and then Listen for the compressor to start.
immediately turned back to a colder position.
• Unit turned off and then on too quickly. If air conditioner is turned off,
wait 3 minutes before restarting.
• Thermostat set too low for cooling. Adjust thermostat to higher setting for cooling.
Air from unit does not • Selector in FAN position. Set selector to COOL position.
feel cold enough • Thermostat set too warm. Set thermostat to colder temperature.
• Room temperature below 70°F. Cooling may not occur until room
temperature rises above 70°F.
Air conditioner cooling, • Outdoor temperature below 70°F. To defrost the coil, set selector to FAN position.
but room is too warm — Then, set thermostat to warmer position.
ice forming on cooling coil • Dirty air filter — air restricted. Clean filter. See “Cleaning the Air Filter” section.
behind decorative front To defrost, set selector to FAN.
• Thermostat set too cold for nighttime cooling. To defrost the coil, set selector to FAN position.
Then, set thermostat to a normal position.
Air conditioner cooling, • Dirty air filter — air restricted. Clean air filter.
but room too warm — Refer to “Cleaning Air Filter” section.
NO ice forming on cooling coil • Thermostat set too warm. Set thermostat to colder setting.
behind decorative front • Fan selector set on LOW. Set fan speed selector to HIGH
for maximum cooling.
Noise when unit is cooling • Air movement sound. The sound of rushing air is normal. If too loud,
turn selector to lower fan setting.
• Sound of fan hitting water-moisture This is normal when humidity is high.
removal system. Close doors, windows and registers.
• Window vibration — poor installation. Refer to installation instructions —
check with installer.
Water dripping inside • Improper installation. Tilt air conditioner slightly to the outside to
when unit is cooling allow water drainage. Refer to installation
instructions — check with installer.
Water dripping outside • Unit removing large quantity of moisture This is normal during excessively humid days.
when unit is cooling from humid room.
Service
To save time and expense, check the following before calling an authorized service center.
Troubleshooting Guide
Insufficient Cooling
•Turn Master Control to OFF.
Shut all windows and doors in room.
Remove any obstructions from inside and outside louvers.
Close Vent Door (available on some models).
Inspect filter and clean if dirty.
•Turn Thermostat and Master Controls to coolest settings.
Under certain conditions the cooling coils directly behind the
filter, may ice up and block the airflow. This is a common
occurrence in air conditioners caused when the outside
temperature drops below 70°F (21°C) while the humidity
remains high. If this happens, simply turn the unit off and allow
the ice to melt, then resume normal operation.
Insufficient Heating- Heating Models Only
•Turn Master Control to OFF.
Shut all windows and doors in room.
Remove any obstructions from inside and outside louvers.
Close Vent.
•Turn Thermostat to Warmer and Master Control to HI HEAT.
Unit Fails to Start
•Turn Master Control to OFF.
Replug line cord plug into outlet to be sure electrical contact
is being made. (If firm contact is not being made, outlet may
have to be replaced).
•Turn Master Control to HI FAN. If air circulating fan does not
operate, check house circuit breaker (or fuses).
9
SERVICE &
WARRANTY
Room Air Conditioner Warranty
(Within the 48 contiguous United States, state of
Hawaii, the District of Columbia, Puerto Rico, Mexico
and Canada)
Full (Five Year) Parts and Labor Warranty
During the five years after the date of original purchase,
Fedders will, through its authorized servicers and free of
charge to the owner or any subsequent user, repair or
replace any parts which are defective in material or
workmanship due to normal use. Ready access to the air
conditioner is the responsibility of the owner.
Note: In the event of any required parts replacement
within the period of this warranty, Fedders replacement
parts shall be used and will be warranted only for the
period remaining on the original warranty.
Exceptions
The above warranty does not cover failure to function
caused by damage to the unit while in your possession
(other than damage caused by defect or malfunction), or by
its improper installation, or by unreasonable use of the unit,
including without limitation, failure to provide reasonable
and necessary maintenance or to follow the written
Installation and Operating Instructions. If the unit is put to
commercial, business, rental, or other use or application
other than for consumer use, we make no warranties,
express or implied, including but not limited to, any implied
warranty of merchantability or fitness for particular use or
purpose.
THE REMEDIES PROVIDED FOR IN THE ABOVE EXPRESS
WARRANTY ARE THE SOLE AND EXCLUSIVE REMEDIES
THEREFOR, NO OTHER EXPRESS WARRANTIES ARE
MADE. ALL IMPLIED WARRANTIES, INCLUDING BUT
NOT LIMITED TO ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE
OR PURPOSE, ARE LIMITED IN DURATION TO FIVE
YEARS FROM THE DATE OF ORIGINAL PURCHASE. IN
NO EVENT SHALL FEDDERS BE LIABLE FOR INDIRECT,
INCIDENTAL, OR CONSEQUENTIAL DAMAGES, EVEN IF
ADVISED IN ADVANCE OF THE POSSIBILITY OF SUCH
DAMAGES. NO WARRANTIES, EXPRESS OR IMPLIED, ARE
MADE TO ANY BUYER UPON RESALE.
Some states do not allow limitations on how long an implied
warranty lasts or do not allow the exclusion or limitation of
incidental or consequential damages, so the above
limitations or exclusions may not apply to you. This
warranty gives you specific legal rights, and you may also
have other rights which may vary from state to state.
How to Obtain Warranty Service or Parts
Note: Before calling for service, carefully read this
Installation and Operations manual.
For Models Installed in North America :
First make the recommended checks in the Troubleshooting
guide. Then, if you still need assistance:
1. Call a CareCo authorized servicer and advise them of model
number, serial number, date of purchase and nature of
complaint. Service will be provided during normal working
hours. Contact your dealer for the name of an authorized
servicer, if unknown to you.
2. If your dealer is unable to give you the name of a servicer or
if you need other assistance, contact CareCo for the name of
an authorized servicer.
You may contact CareCo by email:
by calling the following toll-free number:
1-800-332-6658
or you may write:
CareCo, Service Department
415 W. Wabash Ave., P.O. Box 200
Effingham, IL 62401
For Models Installed Outside North America :
For room air conditioners purchased for use outside North
America, the manufacturer does not extend any warranty either
expressed or implied. Consult your local dealer for any warranty
terms extended by the importer in your country.
Proof of Purchase Date
It is the responsibility of the consumer to establish the original
purchase date for warranty purposes. We recommend that a bill
of sale, cancelled check, or some other appropriate payment
record be kept for that purpose.
Visit www.fedders.com for obtaining service parts beyond your
warranty period.
23-23-0355N-005
B
C
D
E
F
A
Features / Características / Caractéristiques
G
H
Filter / Filtro / Filtre
Decorative Front / Panel Decorativo Delantero /
Panneau de façade décoratif
Air Intake Panel / Panel de Entrada del Aire /
Panneau d’admission d’air
G
H
A
D
C
B
E
F
Adjustable Louvers / Rejillas de
Ventilación ajustables / Claires-
voies orientables
Cabinet / Gabinete / Caisse
Filler Panels / Panel de Relleno /
Panneau de remplissage
Top Bar / Barra Superior /
Tringle supérieure
Power Cord / Cordón / Le
cordon d’alimentation
Standard Window
Installation (Page 3)
Instalación en Ventana
Estándar (Página 11)
Installation dans une fenêtre
standard (page 19)
Minimum Width Window
installation (Page 5)
Instalación en Ventana
de Ancho Mínimo (Página 13)
Installation dans une fenêtre
de largeur minimale (page 21)
Through the wall installation (Page 5)
Instalación Empotrado en una
Pared (Página 13)
Installation à travers un mur (page 21)
Types of Installation / Tipos de Instalación / Types d’installation
Features and specifications subject to change without notice.
Las características y especificaciones están sujetas a cambio sin previo aviso.
Les caractéristiques et spécifications sont sujettes à modifications sans préavis.