Amprobe LCR55A Manuel utilisateur

Catégorie
Multimètres
Taper
Manuel utilisateur

Ce manuel convient également à

User Manual
• Bedienungshandbuch
• Manualdeuso
• Moded’emploi
LCR55A
Inductance, Capacitance,
Resistance Meter
200 2m
2m
FUSED
F
H
200mA MAX
HOLD
HmHH
h
FE
MAX
EBCE
nF FmF
k M
20 ADJ.
20m
200m
2
20
200
NPN
NPN
PNP
PNP
200p
2n
20n
200n
2
20
200
2000
20M
2M
200k
20k
2k 200 20 OFF
hFE
hFE
(Icec A)
(Icec A)
Cx
Lx
Hi(+) Lo(-)
Rx
MAX 350V
FUSED
DISCHARGE CAPACITOR
BEFORE CONNECTING
Lx Cx
LCR55A
M.W.
LCR55A
3-1/2 digit LCD; decimal point, function and unit indicators
3-1/2 Digit LCD ; Dezimalpunkt, Funktions- und Einheitsanzeigen
LCD de 3-1/2 dígitos, punto decimal, indicadores de función y unidades
LCD 3-1/2 digits ; point décimal, indicateurs de fonctions et d'unités
Low Battery
Batterie entladen
Pila baja
Pile déchargée
Zero adjustment for
20Ω range
Nullabgleich für
20Ω Bereich
Ajuste de cero para
escala de 20 Ω
Mise-à-zéro pour
calibre 20Ω
Display Hold
Anzeigesperre
Retención de
lectura
Maintien de
lecture
Max Reading Hold
Max Anzeigesperre
Retención de
lectura maxima
Maintien de lecture
maximale
Positive and negative inputs for resistance
and diode test
Positive und negative Eingänge für
Widerstandsmessung und Diodentest
Entradas positiva y negativa para medidas
de resistencia y prueba de diodos
Entrées positives et négatives pour measures
de résistance et test de diodes
Function/Range/Off
Selector
Funktion-/Bereich-
/Aus Schalter
Selector de
Función/Escala/Off
Sélecteur fonctions/
calibres/marche-
arrêt
Input terminals
for transistor test
Eingänge für
Transistortest
Terminales de
entrada para prueba
de transistors
Entrées pour test
de transistors
High (+) and Low (-) inputs for capacitance
and inductance measurement
Hoch (+) und Niedrig (-) Eingänge für
Kapazitäts- und Induktanzmessung
Entradas alta (+) y baja (-) para medidas de
capacidad e inductancia
Entrées haute (+) et basse (-) pour measures
de capacité et d'inductance
LCR55A
Inductance, Capacitance,
Resistance Meter
Operators Manual
• Bedienungsanleitung
• Manual de Instrucciones
• Manuel d’Utilisation
English
PN 1566247
©2007 Amprobe.
All rights reserved. Printed in Taiwan
Limited Warranty and Limitation of Liability
Your Amprobe product will be free from defects in material and workmanship
for 1 year from the date of purchase. This warranty does not cover fuses,
disposable batteries or damage from accident, neglect, misuse, alteration,
contamination, or abnormal conditions of operation or handling. Resellers are
not authorized to extend any other warranty on Amprobe’s behalf. To obtain
service during the warranty period, return the product with proof of purchase
to an authorized Amprobe Test Tools Service Center or to a Amprobe dealer or
distributor. See Repair Section above for details. THIS WARRANTY IS YOUR ONLY
REMEDY. ALL OTHER WARRANTIES - WHETHER EXPRESS, IMPLIED OR STAUTORY
- INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE
OR MERCHANTABILITY, ARE HEREBY DISCLAIMED. MANUFACTURER SHALL
NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL
DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states
or countries do not allow the exclusion or limitation of an implied warranty or
of incidental or consequential damages, this limitation of liability may not apply
to you.
1
Inductance, Capacitance, Resistance Meter
Contents
Symbols ..............................................................................................................1
Warnings and Precautions ................................................................................ 1
Overload Indication .......................................................................................... 2
Preparation for Use – Unpacking .....................................................................2
Measuring Procedures ...................................................................................... 2
Specifications ..................................................................................................... 4
Troubleshooting/Maintenance ......................................................................... 6
Repair ................................................................................................................. 7
Symbols
Warnings and Precautions
• Do not exceed the maximum overload limits per function (see specifications)
nor the limits marked on the instrument itself.
• Exercise extreme caution when: measuring voltage >20V .
• Inspect DMM, test leads and accessories before every use. Do not use any
damaged part.
• Never ground yourself when taking measurements. Do not touch exposed
circuit elements or probe tips.
• Do not operate instrument in an explosive atmosphere.
• Clean instrument with mild detergent only.
Battery Refer to the manual
Double insulated Audible tone
Fuse  Complies with EU
directives
Conforms to relevant Australian standards
2
OverloadIndication
Range overload is indicated by a “OL” in the display with all
other digits blanked. Overload indication is normal in the
OHMS range with open circuit or too high a resistance.
PreparationforUse–Unpacking
Your shipping carton should include the LCR55A, one test lead set (one black,
one red), one pair of alligator clips, one 9V battery (installed), one spare
0.1A/250V fuse (inside the case), one holster, a warranty card and this manual. If
any item is damaged or missing, return to the place of purchase for an exchange.
MeasuringProcedures
General Procedures
1. When connecting or disconnecting test leads to/from a circuit, always first
turn off power to device or circuit being tested and discharge all capacitors.
2. If the magnitude of a signal to be measured is not known, set selector switch
to highest range first and reduce until satisfactory reading is obtained.
3. Strictly observe the max input limits.
Resistance Measurement (Fig. -1-)
1. Turn off power to the resistance to be measured and discharge any
capacitors. Any voltage present during a resistance measurement will cause
inaccurate readings.
2. Connect red test lead to +Rx Input and black test lead to -Rx Input.
3. Set Function/Range Switch to the desired position.
4. Connect test leads to resistance or circuit to be measured.
5. Read resistance value on Digital Display. Open circuits will be displayed as an
overload condition.
Note: On the 20 range, an adjustment potentiometer (ZERO ADJ.) allows you
to zero out the test lead resistance. Short test leads and adjust the knob until the
display reads zero.
Diode and Transister Test (Fig. -2-)
The diode test measures the voltage drop across the diode junction.
4. Connect the red test lead to the +Rx Input and the black test lead to the –Rx Input.
5. Set the Function/range switch to or to M.W. position (to test diodes
found in microwave ovens).
6. Apply probe tip of red lead to the anode and black lead to the cathode
of the diode. The meter’s display indicates the forward voltage drop
(approximately 0.7V for silicon diode or 0.4V for germanium diode). Meter
will display overload condition for an open diode.
7. Reverse test lead connections to the diode to perform a reverse bias test.
Overload indicates a good diode.
Note: Overload condition for both reverse and forward bias tests indicate an
open diode. A low voltage reading for both bias tests indicates a shorted diode.
If the diode is shunted by a resistor of 1000 ohms or less, it must be removed
from the circuit before taking the measurement. Bipolar transistor junctions may
3
be tested in the same manner described above.
Note: The test procedure of microwave oven diodes is identical to regular diodes
except forward voltage drop will be higher (3 or more volts) than standard
silicon diodes. LEDs may also be tested with the LCR55A in the M.W. position.
Continuity Test
The Continuity test checks electrical continuity between two contact points.
1. Set the Function/Range switch to .
2. Plug the black test lead into the –Rx jack and connect the test lead tip to one
of the contact points.
3. Plug the red test lead into the +Rx jack and connect its test lead point to the
other contact point. (See Figure 1 for connections).
4. The internal beeper emits a tone when resistance is less than approx. 30.
Capacitance Mesurements (Fig. -3-)
1. Discharge all voltage from the capacitor (via a 20k resistor) before
measuring its value.
2. Connect the red test lead to the HI(+) input and the black test lead to the
Lo(–) input.
3. Set the function/range switch to the capacitance range that gives the best
resolution.
4. Apply probe tips to the capacitor leads
5. Read the capacitance value on the display (you may have to wait a few
seconds until the capacitor is fully charged). If “OL” appears in the highest
range, the capacitor is too large to be measured.
Note: Small value capacitors can also be measured by inserting their leads
directly into the Cx/Lx slots in the meter.
Note:The capacitance range is protected by a 0.1A/250V fast blow fuse. If fuse
blows, replace with same (see Battery and Fuse Replacement).
Note: The LCR55A has a residual capacitance of approximately 6pF in the 200nF
range. When using the 200nF range, note the residual capacitance and subtract
this value from the measured value.
Inductance Measurement
1. Connect the red test lead to the HI(+) input and the black test lead to the
Lo(–) input.
2. Set the function/range switch to the inductance range that gives the best
resolution.
3. Apply probe tips to the inductor leads.
4. Read the inductance value on the display. If “OL” appears in the highest
range, the inductor is too large to be measured.
Note: Small value inductors can also be measured by inserting their leads directly
into the Cx/Lx slots in the meter.
Note: The inductance range is protected by a 0.1A/250V fast blow ceramic fuse. If
fuse blows, replace with same (see Battery and Fuse Replacement).
Transistor Gain Measurement
The Transistor must be out of circuit.
4
1. Set the Function/Range switch to the PNP(hFE) or NPN(hFE) position,
according to the type of transistor to be measured.
2. Plug the emitter, base and collector leads of the transistor into the correct
holes of test socket.
3. Read the hFE beta, (DC current gain) in the display.
Note: To measure the collector-emitter current, set the function/range switch to
the corresponding PNP(Icec µA) or NPN(Icec µA) position.
MAX Function
Push the MAX button to keep only the highest reading on the display. The
display is updated each time a higher value is encountered. Push MAX again to
release the display and to display current values.
Hold Function
Press the HOLD button to maintain a reading on the display. The reading is
maintained even when the probe tips are removed from the meter. Pushing the
HOLD button again releases the display.
Safety Test Leads
The test leads included with your meter have shrouded banana plugs to
eliminate the possibility of shock if the plugs accidentally pull out of the meter
while making a measurement. Always inspect the test leads for damage before
making any measurements.
Specications
General Specifications
Display: 3 1/2 digit LCD, 1999 counts, 0.7” (17.8mm) high numerals, unit
annunciators and function symbols
Polarity Indication: Automatic, positive implied, negative indicated
Zero Adjustment: Automatic
Overrange Indication: “OL”
Low Battery Indication: is displayed when the battery voltage drops below
accurate operating level. Change battery immediately.
Display Update Rate: 2.5 per second, nominal
Operating Temperature: 0°C to 50°C, 0 to 70% Relative Humidity
Storage Temperature: -20°C to 60°C, 0 to 80% RH with battery removed
Temperature coefficient: 0.1 x (spec. accur.) per °C (0-18°C, 28-50°C)
Power: Standard 9-volt transistor battery, NEDA 1604, JIS 006P, IEC 6F22
Auto Power Off: 60 minutes after no function or range change
Battery Life (Typical): 30 hours alkaline (changes with function and application)
Dimensions (H x W x D): 18.3 x 7.9 x 3.8 cm, (7.2 x 3.1 x 1.5 inches)
Weight (including battery): 311 grams (11 ounces)
Accessories: Test leads, 0.1A/250V spare fuse, battery, one pair of alligator clips
and Operator’s Manual.
5
Agency Approvals: EMC
This product complies with requirements of the following European
Community Directives: 89/336/EEC (Electromagnetic Compatibility) and 73/23/
EEC (Low Voltage) as amended by 93/68/EEC (CE Marking).
However, electrical noise or intense electromagnetic fields in the vicinity of
the equipment may disturb the measurement circuit. Measuring instruments
will also respond to unwanted signals that may be present within the
measurement circuit. Users should exercise care and take appropriate
precautions to avoid misleading results when making measurements in the
presence of electronic interference
Electrical Specifications
Accuracies at 23°C ± 5°C, <75% RH.
Resistance
Ranges: 20, 200, 2, 20, 200k, 2, 20M
Resolution, 20 range: 10m
Accuracy: 20 range: ±1.2% rdg (zero adjust)
200 range: ±0.5% rdg +3dgt 2k
to 2M rgs: ±(0.5% rdg +1dgt)
20M rg: ±(2.0% rdg +2dgt)
OL Protection, all ranges: 350VDC or AC RMS
Open Circuit Voltage; 20 range: 6.5VDC; 200 range: 3.0VDC;
other ranges: 1.2VDC
Continuity
Audible Indication, 2k rg: at R 30
Response time: 800ms approx
OL Protection: 350VDC or AC RMS
Diode Test
Test Current: 1mA (approx.)
Test Voltage: 3.0VDC typical
Accuracy: ±(1.5%rdg +1dgt)
Display: Forward Junction Voltage
OL Protection: 350VDC or AC RMS
Micro Wave Diode Test
Test Current: 1.3mA (approx.)
Test Voltage: 8.0VDC typical
Accuracy: ±(3.0%rdg +1dgt)
Display: Forward Junction Voltage
OL Protection: 350VDC or AC RMS
Capacitance
Ranges: 200pF, 2, 20, 200nF, 2, 20, 200, 2000µF
Accuracy*:200pF to 200nF: ±(1.0% rdg +3dgt)
2µF to 200µF rgs: ±(2.0% rdg +3dgt)
2000µF range: 1000µF ±(3.0% rdg +3dgt)
>1000µF ±(5.0% rdg +5dgt)
Note:
Residual capacitance must be subtracted from the measurement to meet
the defined specifications.
Test Frequency: 200p to 2µF: 1000Hz; 20, 200µF ranges: 100Hz;
2000µF range: 10Hz
6
Temperature Coefficient: 0.5µF: 0.1%/°C; >0.5µF: 0.2%/°C
OL Protection: 0.1A/250V fast blow fuse.
Inductance
Ranges: 200µH, 2, 20, 200mH, 2, 20, 200H
Accuracy: 200µH rg: ±(5.0%rdg +30dgt)*
2 to 200mH: ±(3.0% +20dgt)*
2 to 200H: ±(5.0% +20dgt)*
*For values of Q 7
Test Frequency: 200µH to 2H rgs: 1000Hz; 20 and 200H ranges: 100Hz
Temperature Coefficient, 0.5H: 0.2%/°C; >0.5H: 0.5%/°C
OL Protection: 0.1A/250V fast blow fuse
Transistor Test
hFE Range: 0-1000
hFE Base Current: 5µA approx.
hFE Voltage C-E: 3.0VDC approx.
Iceo Range, Leakage Current: 10nA to 20µA
Optional Accessories
VC221B Vinyl Carrying Case (for meter and holster)
DL243D Standard Test Lead Set
DL248D Deluxe Test Lead Set
TL36A Replacement Test Leads with Alligator Clips
Troubleshooting/Maintenance
If there appears to be a malfunction during the operation of the meter, the
following steps should be performed in order to isolate the cause of the problem:
Check the battery.
Review the operating instructions for possible mistakes in operating procedure.
Inspect and test the Test Probes for a broken or intermittent connection.
Inspect and test the fuse. See Fuse Replacement.
Except for the replacement of the battery or fuse, repair of the multimeter
should be performed only by a Factory Authorized Service Center or by other
qualified instrument service personnel.
The front panel and case can be cleaned with a mild solution of detergent and
water. Apply sparingly with a soft cloth and allow to dry completely before using.
Battery/Fuse Replacement Warning
To prevent electrical shock hazard, turn off the multimeter
and any device or circuit under test and disconnect the test
leads before removing the rear cover.
1. Remove the screws and lift off the rear case.
2. Fuse Replacement: Remove the blown fuse (5 x 20mm) from the fuse holder.
Replace with a 0.1A/250V quick acting glass fuse (one spare fuse is located on
the right side of the battery compartment). Amprobe replacement fuse part
number is FP 125.
3. Battery replacement: Remove battery and replace with NEDA type 1604 or
equivalent 9 volt alkaline battery.
4. Reassemble the instrument.
7
Warning
Use of an incorrect fuse could result in serious injury or even
death. Failure to turn off the multimeter before installing
the battery could result in damage to instrument and battery.
Repair
All test tools returned for warranty or non-warranty repair or for calibration
should be accompanied by the following: your name, company’s name, address,
telephone number, and proof of purchase. Additionally, please include a brief
description of the problem or the service requested and include the test leads
with the meter. Non-warranty repair or replacement charges should be remitted
in the form of a check, a money order, credit card with expiration date, or a
purchase order made payable to Amprobe Test Tools.
In-Warranty Repairs and Replacement – All Countries
Please read the warranty statement and check your battery before requesting
repair. During the warranty period any defective test tool can be returned
to your Amprobe Test Tools distributor for an exchange for the same or like
product. Please check the “Where to Buy” section on www.amprobe.com for a
list of distributors near you. Additionally, in the United States and Canada In-
Warranty repair and replacement units can also be sent to a Amprobe Test Tools
Service Center (see below for address).
Non-Warranty Repairs and Replacement – US and Canada
Non-warranty repairs in the United States and Canada should be sent to a
Amprobe Test Tools Service Center. Call Amprobe Test Tools or inquire at your
point of purchase for current repair and replacement rates.
In USA In Canada
Amprobe Test Tools Amprobe Test Tools
1420 75th Street SW 400 Britannia Rd. E. Unit #1
Everett, WA 98203 Mississauga, ON L4Z 1X9
Tel: 888-993-5853 Tel: 905-890-7600
Fax: 425-446-6390 Fax: 905-890-6866
Non-Warranty Repairs and Replacement – Europe
European non-warranty units can be replaced by your Amprobe Test Tools
distributor for a nominal charge. Please check the “Where to Buy” section on
www.amprobe.com for a list of distributors near you.
European Correspondence Address*
Amprobe® Test Tools Europe
In den Engematten 14
79286 Glottertal, Germany
Tel.: +49 (0) 7684 8009 - 0
*(Correspondence only – no repair or replacement available from this address.
European customers please contact your distributor.)
8
200 2m
2m
FUSED
F
H
200mA MAX
HOLD
MAX
EBCE
20 ADJ.
20m
200m
2
20
200
NPN
NPN
PNP
PNP
200p
2n
20n
200n
2
20
200
2000
20M
2M
200k
20k
2k 200 20 OFF
hFE
hFE
(Icec A)
(Icec A)
Cx
Lx
Hi(+) Lo(-)
Rx
MAX 350V
FUSED
DISCHARGE CAPACITOR
BEFORE CONNECTING
Lx Cx
LCR55A
M.W.
2
1
Cathode Anode
Cathode
600 - 900 mV
<1 V
Anode
3
2
4
OK
OK
OK
OK
200 2m
2m
FUSED
F
H
200mA MAX
HOLD
MAX
EBCE
k
20 ADJ.
20m
200m
2
20
200
NPN
NPN
PNP
PNP
200p
2n
20n
200n
2
20
200
2000
20M
2M
200k
20k
2k 200 20 OFF
hFE
hFE
(Icec A)
(Icec A)
Cx
Lx
Hi(+) Lo(-)
Rx
MAX 350V
FUSED
DISCHARGE CAPACITOR
BEFORE CONNECTING
Lx Cx
LCR55A
M.W.
4
3
2
5
1
9
3
200 2m
2m
FUSED
F
H
200mA MAX
HOLD
MAX
EBCE
F
20 ADJ.
20m
200m
2
20
200
NPN
NPN
PNP
PNP
200p
2n
20n
200n
2
20
200
2000
20M
2M
200k
20k
2k 200 20 OFF
hFE
hFE
(Icec A)
(Icec A)
Cx
Lx
Hi(+) Lo(-)
Rx
MAX 350V
FUSED
DISCHARGE CAPACITOR
BEFORE CONNECTING
Lx Cx
LCR55A
M.W.
3A
3B
1
2
4
1
Deutsch
LCR55A
Inductance, Capacitance,
Resistance Meter
Operators Manual
• Bedienungsanleitung
• Manual de Instrucciones
• Manuel d’Utilisation
German
Deutsch
2
Beschränkte Gewährleistung und
Haftungsbeschränkung
Es wird gewährleistet, dass dieses Amprobe-Produkt für die Dauer von einem
Jahr ab dem Kaufdatum frei von Material- und Fertigungsdefekten ist. Diese
Gewährleistung erstreckt sich nicht auf Sicherungen, Einwegbatterien oder
Schäden durch Unfälle, Nachlässigkeit, Missbrauch, Änderungen oder abnormale
Betriebsbedingungen bzw. unsachgemäße Handhabung. Die Verkaufsstellen
sind nicht dazu berechtigt, diese Gewährleistung im Namen von Amprobe
zu erweitern. Um während der Gewährleistungsperiode Serviceleistungen zu
beanspruchen, das Produkt mit Kaufnachweis an ein autorisiertes Amprobe Test
Tools Service-Center oder an einen Amprobe-Fachhändler/-Distributor einsenden.
Einzelheiten siehe Abschnitt „Reparatur“ oben. DIESE GEWÄHRLEISTUNG STELLT
DEN EINZIGEN UND ALLEINIGEN RECHTSANSPRUCH AUF SCHADENERSATZ
DAR. ALLE ANDEREN GEWÄHRLEISTUNGEN - VERTRAGLICH GEREGELTE ODER
GESETZLICHE VORGESCHRIEBENE - EINSCHLIESSLICH DER GESETZLICHEN
GEWÄHRLEISTUNG DER MARKTFÄHIGKEIT UND DER EIGNUNG FÜR EINEN
BESTIMMTEN ZWECK, WERDEN ABGELEHNT DER HERSTELLER ÜBERNIMMT KEINE
HAFTUNG FÜR SPEZIELLE, INDIREKTE, NEBEN- ODER FOLGESCHÄDEN ODER
VERLUSTE, DIE AUF BELIEBIGER URSACHE ODER RECHTSTHEORIE BERUHEN.
Weil einige Staaten oder Länder den Ausschluss oder die Einschränkung einer
implizierten Gewährleistung sowie von Begleit- oder Folgeschäden nicht
zulassen, ist diese Gewährleistungsbeschränkung möglicherweise für Sie nicht
gültig.
3
Inductance, Capacitance, Resistance Meter
Inhalt
Symbole ............................................................................................................. 1
Warnungen und Vorsichtsmaßnahmen ........................................................... 1
Überlastanzeige ................................................................................................ 2
Gebrauchsvorbereitung - Auspacken ............................................................... 2
Meßprozeduren ................................................................................................ 2
Spezifikatione .................................................................................................... 4
Fehlersuche/Unterhalt ....................................................................................... 6
Reparatur ........................................................................................................... 7
Symbole
WarnungenundVorsichtsmaßnahmen
• Überschreiten Sie nie die kontinuierlichen Überlastgrenzen per Funktion
(siehe Spezifikationen) oder andere Grenzen welche auf dem Gerät markiert
sind.
• Unsersuchen Sie Gerät, Meßkabel, Verbinder, usw. vor jeder Messung.
Beschädigte Teile nicht verwenden
• Meßspitzen und Stromkreis während der Messung nicht berühren. Sich selbst
isolieren !
• Sicherung immer mit gleichwertiger ersetzen.
• Gerät nicht in explosiver Umgebung verwenden.
Batterie Im Handbuch nachlesen.
Schutzisoliert Übereinstimmung mit
EU-Richtlinien
Sicherung  Akustischer Alarm
Übereinstimmung mit den relevanten australischen standards
4
Überlastanzeige
Wenn ein Signal die Bereichsgrenze überschreitet erscheint das
Symbol “OL” in der Anzeige. Diese Anzeige ist normal bei
Widerstandsmessung wenn Mekabel/spitzen frei stehen oder
wenn der Meßwert den Bereich überschreitet.
Gebrauchsvorbereitung-Auspacken
Die Verpackung sollte enthalten: das LCR55A, ein Meßkabelsatz (ein schwarz,
ein rot), ein Paar Krokodilklemmen, eine 9V Batterie (im Gerät), eine 0.1A/250V
Ersatzsicherung (im Gerät), eine Garantiekarte und diese Anleitung. Wenn
ein Teil fehlt oder beschädigt ist, zur Verkaufstelle für einen Austausch
zurückbringen.
Meßprozeduren
Allgemein
1. Vor Verbinden und Trennen der Meßkabel mit dem Schaltkreis, diesen
abschalten und Kondensatoren entladen.
2. Bei unbekannter Signalgröße, bei höchstem Bereich beginnen und dann
niedriger schalten bis gute Auflösung erreicht wird.
3. Maximale Grenzen nicht überschreiten.
Widerstandsmessung (Fig. -1-)
4. Es darf keine Spannung am Widerstand anliegen. Kondensatoren entladen.
Eine Spannung würde die Messung verfälschen.
5. Rotes Meßkabel mit +Rx Eingang und schwarzes mit -Rx verbinden.
6. Funktionsschalter auf gewünschte Position stellen.
7. Meßspitzen mit Schaltkreis verbinden. Meßwert ablesen. Eine offene
Schaltung wird mit Überlast angezeigt.
Anmerkun: Im 20 Bereich erlaubt ein Abgleichpotentiometer den Widerstand
der Meßkabel zu kompensieren. Meßspitzen kurzschließen und Knopf drehen bis
0 angezeigt wird.
Dioden- und Transistortest (Fig -2-)
Der Diodentest zeigt den Spannungsabfall über den Diodendurchgang
1. Rotes Meßkabel mit +Rx Eingang und schwarzes mit -Rx Eingang verbinden.
2. Funktions-schalter auf oder M.W. (zum Testen von Dioden aus
Microwellenöfen) stellen.
3. Meßkabel mit Diode verbinden – rotes mit Anode; schwarzes mit Kathode.
Spannungsabfall in Durchlaßrichtung ablesen (ung. 0.7V für eine Silikon-
Diode und 0.4V für eine Germaniumdiode. Eine offene Diode wird mit
Überlast angezeigt.
4. Verbindung umdrehen um in Sperrrichtung zu messen. Überlast zeigt eine
gute Diode an.
Anmerkung: Überlast in beiden Richtungen zeigt eine offene Diode an; eine
niedrige Ablesung eine kurzgeschlossene Diode. Transistorübergänge können
wie Dioden getestet werden.
Anmerkung: Der Meßvorgang für Microwellendioden ist der gleiche als für
normale Dioden – nur der Spannungsabfall in Durchlaßrichtung is höher (3V
oder mehr). LEDs können auch in der M.W. Position getestet werden
5
Durchgangstest
1. Funktionsschalter auf stellen.
2. Rotes Meßkabel mit +Rx Eingang und schwarzes mit -Rx Eingang verbinden.
3. Meßspizen mit Schaltkreis verbinden.
4. Bei R 100 wird ein akustische Signal abgegeben.
Kapazitätsmessung (Fig. -3-)
1. Kondensator entladen (über 20k Widerstand).
2. Rotes Meßkabel mit HI(+) Eingang und schwarzes mit LO(-) Eingang
verbinden.
3. Wahlschalter auf den Kapazitätsbereich stellen der die beste Auflösung gibt.
4. Meßspitzen mit Kondensatorleitern verbinden.
5. Meßwert ablesen (Sie müssen vielleicht einige Sekunden warten bis der
Kondensator ganz aufgeladen ist). Wenn im höchsten Bereich “OL”
angezeigt wird, dann ist der Kondensator zu groß um gemessen zu werden.
Anmerkung: Die Anschlüsse kleinerer Kondensatoren können zum Messen auch
gleich in die Cx/Lx Schlitze am LCR55A eingesteckt werden.
Anmerkung: Die Kapazitätsbereiche sind mit einer 0.1A/250V flinken Sicherung
abgesichert. Wenn die Sicherung durchbrennt, mit gleichwertiger ersetzen (siehe
Batterie- und Sicherungswechsel).
Anmerkung: Im 200nF Bereich hat das LCR55A eine Restwertanzeige von
ungefähr 6pF. Notieren Sie diesen Wert und ziehen Sie ihn vom späteren
Meßwert ab.
Induktivitätsmessung
1. Rotes Meßkabel mit HI(+) Eingang und schwarzes mit LO(-) Eingang
verbinden.
2. Funktionsschalter auf den Induktivitätsbereich stellen der die beste
Auflösung gibt.
3. Meßspitzen mit den Spulenanschlüssen verbinden. Meßwert ablesen. Wenn
im höchsten Bereich “OL” angezeigt wird, dann ist die Spule zu groß um mit
dem LCR55A gemessen zu werden.
Anmerkung: Die Anschlüsse kleinerer Spulen können zum Messen auch gleich in
die Cx/Lx Schlitze am LCR55A eingesteckt werden.
Anmerkung: Die Induktivitätsbereiche sind mit einer 0.1A/250V flinken Keramik-
Sicherung abgesichert. Wenn die Sicherung durchbrennt, mit gleichwertiger
ersetzen (siehe Batterie- und Sicherungswechsel).
Transistor hFE Messung
Der Transistor muß vom Schaltkreis entfernt sein.
1. Funktionsschalter gemäß Transistor auf PNP (hFE) oder NPN (hFE) stellen.
2. Emitter-, Basis- und Kollektorausgänge in entsprechende Eingänge des
Testsockels stecken.
3. Verstärkung hFE beta, ablesen.
Anmerkung: Um den Kollektor-Emitterstrom zu messen, Wahlschalter auf
entsprechende PNP(Icec µA) oder NPN(Icec µA) Position stellen.
MAX Funktion
MAX Taste drücken um den höchsten Meßwert auf der Anzeige festzuhalten. Bei
jedem höheren gemessenen Wert wird die Anzeige erneuert. MAX Taste erneut
drücken um die Anzeige freizugeben und den laufenden Wert anzuzeigen.
6
Anzeigesperre
HOLD Taste drücken um den Meßwert auf der Anzeige festzuhalten. Der
Meßwert bleibt erhalten, auch wenn die Meßspitzen vom Schaltkreis entfernt
sind. HOLD Taste erneut drücken um die Anzeige freizugeben.
Sicherheitsmeßkabel
Die Meßkabel haben versenkte Bananenstecker um elektrischen Schock zu
vermeiden. Die Meßspitzen sind zum Teil isoliert, um Kurzschlüsse in dichten
Schaltungen zu vermeiden. Diese Isolation kann entfernt werden.
Spezikatione
Allgemeine Spezifikationen
Anzeige: 3 1/2-stelliges LCD, 1999 Punkte, 0.7” (17.8mm) hohe Ziffern, Einheits-
und Funktionsanzeigen
Polaritätsanzeige: Automatisch, positiv unterstellt, negativ angegeben
Nullabgleich: AutomatischÜberlastanzeige: “OL” Entladene Batterieanzeige:
Batterie sofort wechseln.
Meßrate: 2.5 per Sekunde, nominal
Betriebstemperatur: 0°C bis 50°C, 0
bis 70% Relative Feuchte
Lagertemperatur: -20°C bis 60°C, 0 bis 80% R.F., Batterie entfernt.
Temperaturkoeffizient: 0.1 x (spez. Genauigk.) per °C (0-18°C, 28-50°C)
Stromversorgung: Standard 9-volt Transistorbatterie, NEDA 1604, JIS 006P, IEC
6F22
Automatische Abschaltung: nach 60 Minuten Inaktivität.
Batterielebensdauer (Typisch): 30 Stunden, Alkaline (ändert mit Funktion und
Anwendung)
Abmessung. (HxBxT): 18.3x7.9x3.8 cm
Gewicht (mit Batterie): 311 gr.
Zubehör: Meßkabel, 0.1A/250V Ersatzsicherung, Batterie, ein Paar
Krokodilklemmen, Anleitung.
Zulassungen: EMC
Dieses Produkt beantwortet an die Bestimmungen der folgenden EWG
Richtlinien: 89/336/EEC (Elektromagnetische Kompatibilität) und 73/23/EEC
(Niedrige Spannung) geändert durch 93/68/EEC (CE Marking).
Elektrisches Rauschen und starke magnetische Felder in der direkten
Umgebung des Meßgerätes können jedoch den Meßkreis beeinflussen.
Das Gerät kann auch durch Störsignale im gemessenen Schaltkreis
beeinflußt werden. Der Anwender muß Vorsichtsmaßnahmen treffen um
irreführende Meßergebnisse bei Messungen in der Umgebung von starken
elektromagnetischen Feldern zu vermeiden.
Elektrische Spezifikationen
Genauigkeiten bei 23°C ± 5°C, <75% R.F.
Widerstand
Bereiche: 20, 200, 2, 20, 200k, 2, 20M
Auflösung, 20 Bereich: 10m
Genauigkeit, 20 Bereich: ±1.2% vMW (Nullabgleich)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Amprobe LCR55A Manuel utilisateur

Catégorie
Multimètres
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues