ConnectX
®
-2 VPI Dual Port QSFP and SFP+
Card Users Manual
P/N: MHZH29-XTR, MHZH29-XSR
Rev 1.0
Mellanox Technologies
350 Oakmead Parkway
Sunnyvale, CA 94085
U.S.A.
www.mellanox.com
Tel: (408) 970-3400
Fax: (408) 970-3403
Mellanox Technologies, Ltd.
PO Box 586 Hermon Building
Yokneam 20692
Israel
Tel: +972-4-909-7200
Fax: +972-4-959-3245
© Copyright 2009. Mellanox Technologies, Inc. All Rights Reserved.
Mellanox®, ConnectX®, InfiniBlast®, InfiniBridge®, InfiniHost®, InfiniRISC®, InfiniScale®, and InfiniPCI® are registered
trademarks of Mellanox Technologies, Ltd.
BridgeX and Virtual Protocol Interconnect are trademarks of Mellanox Technologies, Ltd.
All other marks and names mentioned herein may be trademarks of their respective companies.
ConnectX-2 VPI InfiniBand and Ethernet Adapter Card User’s Manual
Document Number: 3157
Rev 1.0
Mellanox Technologies
2
NOTE:
THIS HARDWARE, SOFTWARE OR TEST SUITE PRODUCT (“PRODUCT(S)”) AND ITS RELATED DOCUMENTA-
TION ARE PROVIDED BY MELLANOX TECHNOLOGIES “AS-IS” WITH ALL FAULTS OF ANY KIND AND
SOLELY FOR THE PURPOSE OF AIDING THE CUSTOMER IN TESTING APPLICATIONS THAT USE THE PROD
-
UCTS IN DESIGNATED SOLUTIONS. THE CUSTOMER'S MANUFACTURING TEST ENVIRONMENT HAS NOT
MET THE STANDARDS SET BY MELLANOX TECHNOLOGIES TO FULLY QUALIFY THE PRODUCTO(S) AND/OR
THE SYSTEM USING IT. THEREFORE, MELLANOX TECHNOLOGIES CANNOT AND DOES NOT GUARANTEE
OR WARRANT THAT THE PRODUCTS WILL OPERATE WITH THE HIGHEST QUALITY. ANY EXPRESS OR
IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANT
-
ABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT ARE DISCLAIMED. IN NO EVENT
SHALL MELLANOX BE LIABLE TO CUSTOMER OR ANY THIRD PARTIES FOR ANY DIRECT, INDIRECT, SPE
-
CIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES OF ANY KIND (INCLUDING, BUT NOT LIMITED TO, PAY-
MENT FOR PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR
BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CON
-
TRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
FROM THE USE OF THE PRODUCT(S) AND RELATED DOCUMENTATION EVEN IF ADVISED OF THE POSSIBIL
-
ITY OF SUCH DAMAGE.
ConnectX-2 VPI InfiniBand and Ethernet Adapter Card User’s Manual Rev 1.0
Mellanox Technologies
3
Table of Contents
Table of Contents 3
List of Figures 4
List of Tables 5
Revision History 6
7
About this Manual 7
Chapter 1 Overview 8
1.1 Adapter Cards 8
1.2 Mellanox Part Numbering Legend 9
1.3 Finding the GUID/MAC and Serial Number on the Adapter Cards 10
Chapter 2 VPI Adapter Card Installation 12
2.1 Hardware and Software Requirements 12
2.2 Installation Instructions 12
2.3 Safety Warnings 12
2.4 Cables and Modules 13
2.5 Cable Lengths 16
Chapter 3 Driver Software and Firmware 17
3.1 Driver Software 17
3.2 Updating Adapter Card Firmware 17
3.3 Single Adapter Card Firmware Update 17
Chapter 4 Adapter Card Interfaces 18
4.1 I/O Interfaces 18
4.2 Power 20
4.3 Memory 20
4.4 VPD Layout for these Adapter Cards 21
Chapter 5 Replacing a Tall Bracket With a Short Bracket 23
5.1 Remove the Existing Bracket from the Adapter Card 23
5.2 Installing the New Bracket 23
Appendix A Specifications 25
A.1 Board Mechanical Drawing and Dimensions 25
A.2 EMC Certification Statements 26
A.3 MHZH29-X[ST]R Specifications 28
Appendix B Interface Connectors Pinout 29
B.1 I2C-Compatible Connector Pinout 29
B.2 PCI Express x8 Connector Pinout 29
B.3 QSFP Connector Pinout 30
B.4 SFP+ Connector Pinout 32
Appendix C Avertissements de sécurité d’installation (Warnings in French) 34
Appendix D Sicherheitshinweise (Warnings in German) 36
Rev 1.0
Mellanox Technologies
4
List of Figures
Figure 1: Component Side 9
Figure 2: Card Product Label 11
Figure 3: SFP+ Transceiver Module 14
Figure 4: Module With Locking Mechanism Closed 14
Figure 5: Module With Locking Mechanism Open 14
Figure 6: Connector Orientation 15
Figure 7: Port Numbering 18
Figure 8: Physical and Logical Link Indications 19
Figure 9: I2C Connector 20
Figure 10: Flash Jumper 20
Figure 11: Adapter Card 23
Figure 12: Placing the Bracket on the Card 24
Figure 13: Schematic of the ConnectX-2 MHZH Adapter Card 25
Figure 14: Compatible Connector Plug and Pinout 29
Figure 15: Connector and Cage Views 31
Figure 16: Rear View of Module With Pin Placement 32
ConnectX-2 VPI InfiniBand and Ethernet Adapter Card User’s Manual Rev 1.0
Mellanox Technologies
5
List of Tables
Table 1: Revision History Table 6
Table 2: Documents List 7
Table 3: Mellanox Cards Part Numbering Key 9
Table 4: Hardware and Software Requirements 12
Table 5: Jumper Configuration 20
Table 6: Specifications for MHZH29-XTR 28
Table 7: I2C-compatible Connector Pinout 29
Table 8: SFP+ Connector Pinout 33
Rev 1.0
Mellanox Technologies
6
Revision History
This document was printed on 11/3/09.
Table 1 - Revision History Table
Date Rev Comments/Changes
October
2009
1.0 Initial Release
ConnectX-2 VPI InfiniBand and Ethernet Adapter Card User’s Manual Rev 1.0
Mellanox Technologies
7
About this Manual
This Users Manual describes Mellanox Technologies ConnectX
®
-2 VPI IB and Ethernet PCI
Express x8 adapter cards. It provides details as to the interfaces of the board, specifications,
required software and firmware for operating the board, and relevant documentation.
Intended Audience
This manual is intended for the installer and user of these cards.
The manual assumes basic familiarity with InfiniBand® and Ethernet networks and architecture
specifications.
Related Documentation
Table 2 - Documents List
Online Resources
Mellanox Technologies Web pages: http://www.mellanox.com
Mellanox Technologies Firmware download Web page:
http://www.mellanox.com
=> Downloads => Firmware
Document Conventions
When discussing memory sizes, MB and MBytes are used in this document to mean size in mega
bytes. The use of Mb or Mbits (small b) indicates size in mega bits.
Mellanox Firmware Tools (MFT) Users
Manual
Document no. 2204UG
Users Manual describing the set of MFT firmware management
tools for a single InfiniBand node.
See http://www.mellanox.com > Downloads > Firmware Tools
IBTA Specification Release 1.2.1 InfiniBand Architecture Specification
IEEE Std 802.3 Specification This is the IEEE Ethernet specification
http://standards.ieee.org/getieee802
PCI Express 2.0 Specifications Industry Standard PCI Express 2.0 Card Electromechanical Speci-
fication, Rev 1.3.
OverviewRev 1.0
Mellanox Technologies
8
1 Overview
This document is a Users Manual for Mellanox Technologies network VPI adapter cards based on
the MT25408 ConnectX
®
-2 VPI integrated circuit device. The cards described in this manual have
the following main features:
IBTA v1.2.1 compliant
IEEE Std 802.3 compliant
QSFP port for connecting InfiniBand traffic at 10Gb/s (SDR), 20Gb/s (DDR), or 40Gb/s (QDR)
SFP+ port for connecting Ethernet traffic at 10 Gb/s
Compliant with QSFP MSA spec Rev. 1.0
Compatible with copper cables and optical cables with the use of QSFP and SFP+ connectors
PCI Express 2.0 (1.1 compatible) through an x8 edge connector up to 5GT/s
‘Media detect circuit’ with powered connector support for the use of active cables and external
PHY fiber solutions
EU Restriction of Hazardous Substances (RoHS) compliant
10 Gb/s Ethernet
1.1 Adapter Cards
The MHZH29 card is a VPI adapter card with a 40Gb/s InfiniBand QSFP connector and a 10GigE
SFP+ connector.
The QSFP connector is compatible with:
Gigabit Ethernet
InfiniBand Architecture Specifications
•Fibre Channel
The SFP+ connector is compatible with 10GigE.
Table 3 lists the VPI adapter cards described in this manual.
Table 3 - Adapter Cards List
Ordering Part
Number (OPN)
IB QSFP
Port Speed
ETH SFP+
Port Speed
Short /
Tall
Bracket
RoHS
Adapter IC
Part Number
MHZH29-XTR 40Gb/s (QDR) 10Gb/s Tall RoHS-R6 MT25408B0-FCCR-QI
MHZH29-XSR 40Gb/s (QDR) 10Gb/s Short RoHS-R6 MT25408B0-FCCR-QI
ConnectX-2 VPI InfiniBand and Ethernet Adapter Card User’s Manual Rev 1.0
Mellanox Technologies
9
Figure 1: Component Side
1.2 Mellanox Part Numbering Legend
Table 4 describes the Mellanox Technologies adapter cards part numbering legend.
Table 4 - Mellanox Cards Part Numbering Key
Adapter Card
OPN
MHTS#I-XBR
Field Decoder
M Mellanox
Technolo-
gies
H Adapter
Type
H = InfiniBand Host Channel Adapter, N = Ethernet Network Interface Card,
T Media E = CX4 SDR, G = CX4 DDR, J = CX4 QDR,
Q = QSFP QDR, R = QSFP DDR, T = UTP,
Z = one SFP+ connector and one QSFP connector
S Silicon
H = ConnectX
®
, S = InfiniHost III Lx
®
, T= InfiniHost
®
,A = InfiniHost III Ex,
S = InfiniHost III Lx, T = InfiniHost
# # ports 1 = 1, 2 = 2,
OverviewRev 1.0
Mellanox Technologies
10
For example, the part number MHZH29-XTR describes Mellanox Technologies’ ConnectX-2 card
with dual ports one SFP+ and one QSFP, a PCIe2.0 x8 5.0GT/s interface, no on-board memory
(mem-free), a short PCI bracket, and RoHS R5 compliance. Using the legend,
field M = M to indicate a Mellanox Technologies product,
field H = H to indicate an InfiniBand Adapter Card,
field T = Z to indicate QSFP (IB QDR) and SFP+ (10GigE),
field S = H to indicate the ConnectX family,
field # = 2 to indicate two ports,
field I = 9 to indicate PCI Express 2.0 x8 running at 5.0GT/s,
field X = X to indicate no on-board memory,
field B = T to indicate a tall bracket, and
field R = R to indicate RoHS R6 (lead free) compliance
1.3 Finding the GUID/MAC and Serial Number on the Adapter Cards
All Mellanox adapter cards have a label on the printed side of the adapter card that has the card
serial number, the card MAC for Ethernet protocol and the card GUID for InfiniBand protocol.
VPI Cards have both a MAC and a GUID.
IHost Inter-
face
X = PCI-X, 4 = PCIe x4, 8 = PCIe x8, 9 = PCIe (SerDes @ 5.0 GT/s)
G Generation <blank> = Initial product generation
- Separator
XMemory
Size
X = MemFree, 1=128MB, 2=256MB, 3=512MB
B Bracket S = Short, T = Tall, N = None
R RoHS <blank> = non RoHS, C = RoHS R-5 w/ Exemption, R = RoHS R-6 Lead-Free
Table 4 - Mellanox Cards Part Numbering Key
Adapter Card
OPN
MHTS#I-XBR
Field Decoder
ConnectX-2 VPI InfiniBand and Ethernet Adapter Card User’s Manual Rev 1.0
Mellanox Technologies
11
Figure 2: Card Product Label
S/N:MT0744X00012
P/N:MHZH29-XTR
GUID: 0002C9030005646 C
Made in IL
REV: X1
MAC: 0002C901122642 FC
VPI Adapter Card InstallationRev 1.0
Mellanox Technologies
12
2 VPI Adapter Card Installation
2.1 Hardware and Software Requirements
Before installing the adapter card, please make sure that the system meets the hardware and soft-
ware requirements listed in Table 5, “Hardware and Software Requirements”. Refer to Chapter
3,“Driver Software and Firmware” on page 17 for download and installation instructions.
2.2 Installation Instructions
Read all installation instructions before connecting the equipment to the power source.
2.2.1 Installation Instructions as per Host Machine
The adapter cards listed in Table 3 on page 8 are standard PCI Express cards, each with a standard
x8 edge connector. Please consult the host machine documentation for instructions on how to
install a PCI Express card.
2.3 Safety Warnings
1. Installation Instructions
2. Over-temperature
Table 5 - Hardware and Software Requirements
Requirement Description
Hardware PCI Express x8 or x16 slots
Software
Operating
Systems/Distributions
For Windows
IB see http://www.mellanox.com => Downloads => InfiniBand
SW/ Windows Drivers
Ethernet see http://www.mellanox.com => Downloads => Ethernet
SW/ Windows Drivers
For Linux, both the InfiniBand and Ethernet drivers are in the Mellanox OpenFab-
rics Enterprise Distribution (OFED) software package available via the Mellanox
OpenFabrics Web site
http://www.mellanox.com => Downloads => InfiniBand/VPI SW/ Linux Drivers
Read all installation instructions before connecting the equipment to the power
source.
This equipment should not be operated in an area with an ambient temperature
exceeding the maximum recommended: 55°C (131°F).
To guarantee proper air flow, allow at least 8cm (3 inches) of clearance around
the ventilation openings.
ConnectX-2 VPI InfiniBand and Ethernet Adapter Card User’s Manual Rev 1.0
Mellanox Technologies
13
3. During Lightning - Electrical Hazard
4. Copper InfiniBand Cable Connecting/Disconnecting
5. Equipment Installation
6. Equipment Disposal
7. Local and National Electrical Codes
8. Exposure to Radiation
2.4 Cables and Modules
This card can be connected using direct copper cables or optical cables using an SFP+ transceiver
module. Copper cables can be both active and passive.
During periods of lightning activity, do not work on the equipment or connect
or disconnect cables.
Copper InfiniBand cables are heavy and not flexible, as such they should be
carefully attached to or detached from the connectors. Refer to the cable manu-
facturer for special warnings and instructions.
This equipment should be installed, replaced, or serviced only by trained and
qualified personnel.
Disposal of this equipment should be in accordance to all national laws and
regulations.
This equipment should be installed in compliance with local and national elec-
trical codes.
Caution – Use of controls or adjustment or performance of procedures other
than those specified herein may result in hazardous radiation exposure.
CLASS 1 LASER PRODUCT and reference to the most recent laser standards
IEC 60 825-1:1993 + A1:1997 + A2:2001 and EN 60825-1:1994+A1:1996+
A2:2001
VPI Adapter Card InstallationRev 1.0
Mellanox Technologies
14
The adapter cards are shipped without optical modules. Approved modules must be purchased
from Mellanox. The OPNs for the approved Mellanox modules are MFM1T02A-SR and
MFM1T02A-LR. The figure below shows the Mellanox approved SFP+ module.
Note: SR and LR modules not recommended by Mellanox may not work with the adapter.
Figure 3: SFP+ Transceiver Module
2.4.1 Inserting the Optical Transceiver Module
To insert the module into the cage:
1. Open the module’s locking mechanism – see Figure 4 and Figure 5.
2. Make sure that the male connectors on the module will align with the female connectors inside
of the cage. Also check that there is no dirt or foreign matter in the module or in the cage.
Figure 4: Module With Locking Mechanism Closed
Figure 5: Module With Locking Mechanism Open
3. Insert the module into the adapter card module cage.
4. Close the locking Mechanism.
To remove the module from the cage:
1. Unlock the locking mechanism by opening the handle.
2. Pull the module out of the cage.
2.4.2 Cable Installation
All cables can be inserted or removed with the unit powered on. To insert a cable, press the con-
nector into the port receptacle until the connector is firmly seated. The GREEN LED indicator will
light when the physical connection is established (that is, when the unit is powered on and a cable
is plugged into the port with the other end of the connector plugged into a functioning port). After
plugging in a cable, lock the connector using the latching mechanism particular to the cable ven-
dor. When a logical connection is made the YELLOW LED will come on. When data is being
transferred the YELLOW LED will blink.
ConnectX-2 VPI InfiniBand and Ethernet Adapter Card User’s Manual Rev 1.0
Mellanox Technologies
15
Note: When installing cables make sure that the latches engage.
Note: Always install and remove cables by pushing or pulling the cable and connector in a
straight line with the card.
To remove a cable, disengage the locks and slowly pull the connector away from the port recepta-
cle. Both LED indicators will turn off when the cable is unseated.
2.4.2.1 Inserting a Cable into the Adapter Card
1. Support the weight of the cable before connecting the cable to the adapter card. Do this by using
a cable holder or tying the cable to the rack.
2. Determine the correct orientation of the connector to the card before inserting the connector. Do
not try and insert the connector up side down. This may damage the adapter card.
3. Insert the connector into the adapter card. Be careful to insert the connector straight into the
cage. Do not apply any torque, up or down, to the connector cage in the adapter.
4. Make sure that the connector locks in place.
Figure 6: Connector Orientation
2.4.2.2 Removing a Cable from the Adapter Card
1. Pull on the latch release mechanism thereby unlatching the connector and pull the connector out
of the cage.
2. Do not apply torque to the connector when removing it from the adapter card.
Cables, especially long copper cables, can weigh a substantial amount. Make
sure that the weight of the cable is supported on its own and is not hanging
from the adapter card.
180
o
Tie the
Cable to the
Rack
VPI Adapter Card InstallationRev 1.0
Mellanox Technologies
16
3. Remove any cable supports that were used to support the cable’s weight.
2.5 Cable Lengths
Mellanox Cards support up to 40 Gb/s IB and Ethernet over the QSFP port, and up to 10Gb/s on
the SFP+ connector.
2.5.1 InfiniBand Connectivity
These Mellanox Cards support QSFP passive copper connectivity up to 7 meters, and active cable
support up to 50 meters.
2.5.2 Ethernet Connectivity
These Mellanox Cards support ethernet connectivity as defined in IEEE Std 802.3. ae standard.
The described adapter cards can be connected to switches and routers using cable lengths as speci-
fied in the tables below.
These cards are able to support direct attached copper cables. Check www.mellanox.com => Prod-
ucts => Cables for cable recommendations regarding direct attached copper cables.
Table 6 - Max SR Cable Lengths
Cable Max Length of Approved Cable
OM-2 82m
OM-3 330m
Table 7 - Max LR Cable Lengths
Cable Max Length of Approved Cable
SMF 10 Km
ConnectX-2 VPI InfiniBand and Ethernet Adapter Card User’s Manual Rev 1.0
Mellanox Technologies
17
3 Driver Software and Firmware
3.1 Driver Software
For Linux, download and install the latest OpenFabrics Enterprise Distribution (OFED) software
package available via the Mellanox OpenFabrics Web site at:
http://www.mellanox.com => Downloads => InfiniBand/VPI SW/Drivers. Follow the installation
instructions included in the download package.
3.2 Updating Adapter Card Firmware
Each card is shipped with the latest version of qualified firmware at the time of manufacturing.
Firmware is updated occasionally, and the most recent firmware can be obtained from
http://www.mellanox.com => Downloads => Firmware.
3.3 Single Adapter Card Firmware Update
Firmware can be updated on the stand alone single card using the flint tool of the Mellanox Firm-
ware Tools (MFT) package. This package is available for download, along with its users manual,
from the Mellanox Firmware Tools page. See http://www.mellanox.com => Downloads => Firm-
ware Tools.
A firmware binaries table lists a binary file per adapter card. The file name of each such binary is
composed by combining the firmware name, the firmware release version, and the card part num-
ber. Please contact Mellanox or your assigned Field Application Engineer if you cannot find the
firmware binary for your adapter card. This may happen if the product is not yet available for gen-
eral distribution.
Adapter Card InterfacesRev 1.0
Mellanox Technologies
18
4 Adapter Card Interfaces
4.1 I/O Interfaces
Each adapter card includes the following interfaces:
QSFP Optical Connector
SFP+ Ethernet Connector
PCI Express x8 edge connector
I/O panel LEDs
•I
2
C compatible connector (for debug)
Port 1 connects to the IB port of the device, while port 2 connects to the Ethernet port of the
device. See Figure 7,“Port Numbering”
Figure 7: Port Numbering
4.1.1 InfiniBand Interface
The ConnectX-2 VPI device (MT25408B0) is compliant with the InfiniBand Architecture Specifi-
cation, Release 1.2.1. It has a compliant 4X InfiniBand port, with four Tx/Rx pairs of SerDes.
Each of the VPI adapter cards (listed in Table 3 on page 8) based on this device provides access to
its port by means of a QSFP connector.
This port utilizes a ‘media detect circuit’ that supports active copper cables and fiber solutions to
be connected to the InfiniBand port connectors.
4.1.2 Ethernet SFP+ Interface
The ConnectX
®
-2 device is compliant with the IEEE Std 802.3ae 10 Gigabit Ethernet and the
IEEE Std 802.3aq 10GBASE LRM. The SFP+ port has one Tx/Rx pair of SerDes. Each of the cards
(listed in Table 3 on page 8) based on this device provides access to their Ethernet port by means
of copper or optical cables.
Port 2
Ethernet
Port 1
IB port
ConnectX-2 VPI InfiniBand and Ethernet Adapter Card User’s Manual Rev 1.0
Mellanox Technologies
19
4.1.3 PCI Express Interface
The ConnectX-2 adapter cards support PCI Express 2.0 (1.1 compatible) through an x8 edge con-
nector.
4.1.4 LED Assignment
The board has I/O LEDs located on the I/O panel. The green LED, when lit, indicates that the
driver is running and a valid physical connection between nodes exists. If the green LED is blink-
ing, it indicates a problem with the physical link. The yellow LED when lit, indicates a valid data
activity link, this is the logical link. The yellow LED illuminates when the network is discovered
over the physical link. A valid data activity link without data transfer is designated by a constant
yellow LED indication. A valid data activity link with data transfer is designated by a blinking yel-
low LED indication. If the LEDs are not active, either the physical link or the logical link (or both)
connections have not been established.
Figure 8: Physical and Logical Link Indications
Note: The short bracket has the same port and LED footprint as the tall bracket.
4.1.5 I
2
C Compatible Interface
A three-pin header on the adapter card is provided as the I
2
C compatible interface. See
Figure 13,“Schematic of the ConnectX-2 MHZH Adapter Card” for the location on the board.
Table 8 - LEDs
Port Number LED Name
Port 1 Physical Link - Green
Constant on indicates a good physical link
Blinking indicates a problem with the
Physical link
Data Activity - Yellow
Blinking indicates Data Transfer
Constant on indicates no Data Transfer
Port 2 Physical Link - Green
Constant on indicates a good physical link
Blinking indicates a problem with the
Physical link
Data Activity - Yellow
Blinking indicates Data Transfer
Constant on indicates no Data Transfer
Port 1
Port 2
Adapter Card InterfacesRev 1.0
Mellanox Technologies
20
Figure 9: I
2
C Connector
4.2 Power
All adapter cards receive 12V and 3.3V power from the PCI Express Edge connector. All other
required power voltages are generated by on-board switch mode regulators. See “Specifications”
on page 25.
4.3 Memory
The adapter cards support multiple memory devices through the PCI Flash, and I2C-compatible
interfaces. The adapter card utilizes the PCI Express interface to store and access IB fabric and/or
EN fabric connection information and packet data on the system memory.
4.3.1 Flash
Each of the adapter cards include one 16MB SPI Flash device M25P16-VME6G device by ST
Microelectronics) accessible via the Flash interface of the MT25408B0 ConnectX-2 VPI device.
There is a jumper on each adapter card that indicates to the device whether an on-board Flash
device is to be used. Table 9 provides information on this jumper. See Figure 13,“Schematic of the
ConnectX-2 MHZH Adapter Card” for the jumper location.
4.3.2 EEPROM
Each board incorporates an EEPROM that is accessible through the I2C-compatible interface. The
EEPROM is used for storing the Vital Product Data (VPD). The VPD format adheres to the PCI
Local Bus Specification Rev 2.3 VPD definition. The EEPROM capacity is 4Kb.
Table 9 - Jumper Configuration
Description Option
Card Default
Configuration
Comments
Flash present/
not present
connection open – Flash present
connection shorted – Flash not present
Figure 10:
Flash Jumper
connection
open – Flash
present
Header 1x2
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37

Mellanox Technologies MHZH29-XSR Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues