Berkeley BPD Series Corrosion Resistant Self-Priming Centrifugal Pump Le manuel du propriétaire

Catégorie
Pompes à eau
Taper
Le manuel du propriétaire

Ce manuel convient également à

293 WRIGHT STREET, DELAVAN, WI 53115 WWW.BERKELEYPUMPS.COM
PH: 888-782-7483
owner's Manual
Corrosion Resistant
Self-Priming Centrifugal Pump
© 2013 Pentair, Ltd. All Rights Reserved. BE190 (Rev. 02/22/13)
Installation/Operation/Parts
For further operating, installation, or maintenance assistance:
Call 1-888-782-7483
L
1
7
6
-
3
5
P
3774 1000
BPD
Safety 2
READ AND FOLLOW
SAFETY INSTRUCTIONS!
This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for
one of the following signal words and be alert to the
potential for personal injury:
warns about hazards that will cause serious
personal injury, death or major property damage if
ignored.
warns about hazards that can cause serious
personal injury, death or major property damage if
ignored.
warns about hazards that will or can cause
minor personal injury or property damage if ignored.
The label NOTICE indicates special instructions which
are important but not related to hazards.
Carefully read and follow all safety instructions in this
manual and on pump.
Keep safety labels in good condition.
Replace missing or damaged safety labels.
California Proposition 65 Warning
This product and related accessories contain
chemicals known to the State of California to cause
cancer, birth defects or other reproductive harm.
ELECTRICAL SAFETY
Wire motor for correct
voltage. See “Electri cal”
section of this manual
and motor nameplate.
Ground motor before
connecting to power
supply.
Meet National Electri cal
Code, Canadian Elec tri-
cal Code, and local
codes for all wiring.
Follow wiring
instructions in this
manual when
connecting motor to
power lines.
Make workshops childproof; use padlocks and master
switches; remove starter keys.
Do not touch an operating motor. Modern
motors are designed to operate at high temperatures. To
avoid burns when servicing pump, allow it to cool for 20
minutes after shut-down before handling.
GENERAL SAFETY
Pump is designed as a lawn sprinkler only. To avoid heat
built-up, over pressure hazard and possible injury, do not
use in a pressure tank (domestic water) system. Do not use
as a booster pump; pressurized suction may cause pump
body to explode.
Do not allow pump or piping system to freeze. Freezing
can damage pump and pipe, may lead to injury from
equipment failure and will void warranty.
Pump water only with this pump.
Periodically inspect pump and system components.
Wear safety glasses at all times when working on pumps.
Keep work area clean, uncluttered and properly lighted;
store properly all unused tools and equipment.
Keep visitors at a safe distance from the work areas.
WARNING
Hazardous pressure!
Do not run pump against
closed discharge.
Release all pressure on
system before working on
any component.
WARNING
Hazardous voltage.
Can shock, burn, or
cause death.
Ground pump before
connecting to power
supply.
Table of Contents 3
Thank you for purchasing a top quality, factory tested pump.
Page
General Safety .....................................................................................................2
Warranty..............................................................................................................3
Installation ........................................................................................................4-6
Electrical ........................................................................................................... 7,8
Operation ............................................................................................................9
Maintenance .................................................................................................10-12
Troubleshooting ................................................................................................. 13
Repair Parts .................................................................................................14,15
Limited Warranty
BERKELEY warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free
from defects in material and workmanship for the Warranty Period shown below.
Product Warranty Period
Water Systems:
Water Systems Products — jet pumps, small centrifugal pumps, submersible pumps and
related accessories
whichever occurs first:
12 months from date of original installation, or
18 months from date of manufacture
Pro-Source™ Composite Tanks 5 years from date of original installation
Pro-Source™ Steel Pressure Tanks 5 years from date of original installation
Pro-Source™ Epoxy-Lined Tanks 3 years from date of original installation
Sump/Sewage/Effluent Products
12 months from date of original installation, or
18 months from date of manufacture
Agricultural/Commercial:
Centrifugals – close-coupled motor drive, frame mount, SAE mount, engine drive, VMS, SSCX,
SSHM, solids handling, submersible solids handling
12 months from date of original installation, or
24 months from date of manufacture
Submersible Turbines, 6” diameter and larger
12 months from date of original installation, or
24 months from date of manufacture
Our limited warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication,
improper installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase
power through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg,
ambient compensated, extra-quick trip overload relays of the recommended size or the warranty is void.
Your only remedy, and BERKELEY’s only duty, is that BERKELEY repair or replace defective products (at BERKELEY’s choice). You
must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing
dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty Period has
expired. This warranty is not transferable.
BERKELEY SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES,
INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an
implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You
may also have other rights which vary from state to state.
This Limited Warranty is effective June 1, 2011 and replaces all undated warranties and warranties dated before June 1, 2011.
In the U.S.: BERKELEY, 293 Wright St., Delavan, WI 53115
In Canada: 269 Trillium Dr., Kitchener, Ontario N2G 4W5
Installation 4
BEFORE YOU INSTALL YOUR PUMP
NOTICE: Well must not be more than 20' depth to water.
1. Long runs and many fittings increase friction and reduce flow. Locate
pump as close to well as possible: use as few elbows and fittings as
possible.
2. Be sure well is clear of sand. Sand will plug the pump and void the
warranty.
3. Protect pump and all piping from freezing. Freezing will split pipe,
damage pump and void the warranty. Check locally for frost protection
requirements (usually pipe must be 12" below frost line and pump must
be insulated).
4. Be sure all pipes and foot valve are clean and in good shape.
5. No air pockets in suction pipe.
6. No leaks in suction pipe. Use PTFE pipe thread sealant tape to seal pipe
joints.
7. Unions installed near pump and well will aid in servicing. Leave room
to use wrenches.
8.
Pump body may explode if used as a booster pump.
DO NOT use in a booster appli cation.
NOTICE: Use the installation method below which matches your well type.
1096 0697
Pump
Body
From
Well
Dirt and Scale Plug Pump and Pipes!
Use New Pipe for Best Results.
Clean Flow!
Figure 1 – No Dirt or Scale in Suction
Pipe
1100 0697
Figure 2 – Foot Valve Must Work
Freely
Figure 3 – No Air Pockets in Suction
Pipe
No Sags
Sags Allow Air Pockets
If Air Pockets Form, Water Won’t Flow.
Keep Pipe Straight and Angled up to Pump.
1101 0697
No air leaks In
Suction pipe.
If air flows
water won’t
Use PTFE tape.
Use PTFE pipe thread sealant tape or pipe joint
compound approved for use on PVC.
Figure 4 – Suction Pipe Must Not Leak
Models BPDH10-L and BPDH15-L have 2" NPT suction and 1-1/2” NPT discharge.
Models BPDH20-L and BPDH25-L have 2" NPT suction and discharge.
PERFORMANCE CHART (in gallons per minute) – High Head
BPDH10-L BPDH15-L BPDH20-L BPDH25-L
Disch. Distance Above Water
Press
5' 10' 15' 20' 5' 10' 15' 20' 5' 10' 15' 20' 5' 10' 15' 20'
PSI
Capacity – Gallons Per Minute
10 55 49 48 45 67 61 56 46 69 67 65 62 92 83 81 78
15 51 46 45 44 66 58 55 45 65 63 60 58 86 79 78 76
20 45 42 39 37 61 56 54 44 59 56 54 52 80 76 75 74
25 38 35 32 29 55 52 51 43 52 50 48 45 73 71 70 69
30 31 28 24 20 48 45 44 38 47 45 42 40 66 66 65 64
35 23 19 16 11 39 37 34 28 42 38 35 32 60 60 59 58
40 17 13 8 33 27 20 11 34 30 27 23 55 54 53 52
45 18 14 8 25 17 10 47 46 46 45
50 14 7 40 38 37 36
Installation 5
CASED WELL INSTALLATION
1. Inspect foot valve to be sure it works freely. Inspect strainer to be sure it
is clean.
2. Connect foot valve and strainer to the first length of suction pipe and
lower pipe into well. Add sections of pipe as needed, using PTFE pipe
thread sealant tape on male threads. Be sure that all suction pipe is
leakproof or pump will lose prime and fail to pump. Install foot valve
10 to 20 feet below the lowest level to which water will drop while
pump is operating (pumping water level). Your well driller can furnish
this in formation.
3. To prevent sand and sediment from entering the pumping system, the
foot valve/strainer should be at least 5 feet above the bottom of the well.
4. When the proper depth is reached, install a sanitary well seal over the
pipe and in the well casing. Tighten the bolts to seal the casing.
5. When using a foot valve, a priming tee and plug as shown in Figure 5
are recommended.
DUG WELL INSTALLATION
Same as cased well installation.
DRIVEN POINT INSTALLATION
1. Connect the suction pipe to the drive point as illustrated in Figure 6.
Keep horizontal pipe run as short as possible. Use PTFE pipe thread
sealant tape on male pipe threads. Multiple well points may be
necessary to provide sufficient water to pump.
2. Install a check valve in horizontal pipe. Flow arrow on check valve
must point toward pump.
HORIZONTAL PIPING FROM WELL TO PUMP
1. Never install a suction pipe that is smaller than the suction port of the
pump.
2. To aid priming on well point installations, install a line check valve as
shown in Figure 6. Be sure check valve flow arrow points toward pump.
DISCHARGE PIPE SIZES
1. If increasing discharge pipe size, install reducer in pump discharge port.
Do not increase pipe size by stages.
2. When the pump is set away from the points of water use, the discharge
pipe size should be increased to reduce pressure losses caused by
friction.
•Upto100'run:Samesizeaspumpdischargeport.
•100'to300'run:Increaseonepipesize.
•300'to600'run:Increasetwopipesizes.
LAWN SPRINKLING APPLICATION
This pump is designed for lawn sprinkling. It is de signed to deliver plenty
of water at full sprinkler pres sure. It can pump from a pond, cistern or well
points.
Pump discharge can be divided to supply two (2) or more sprinkler
systems. A suggested multiple dis charge to service is shown in Figure 7.
Suction
pipe
Foot
Valve
Priming plug
Priming tee
Standing water
level (pump off)
Drawdown water
level (pump on)
10-20' (3-6 m)
20' (6 m) max.
At least 5 feet (1.5 m)
828 0993
Figure 5 – Cased/Dug Well Installation
Check valve
Steel drive pipe
Drive coupling
Driven point
745 0993
Figure 6 – Driven Point Installation
P
561 1193
Gate
Valve
To
Service
Priming
Plug
Figure 7 – Multiple Discharge
Installation 6
Do not use in a pressure tank or booster pump application.
PUMP INSTALLATION
NOTICE: Use only PTFE pipe thread sealant tape for making all threaded
connections to the pump itself. Do not use pipe joint compounds on
plastic pumps: they can react with the plastic in the pump components.
Make sure that all pipe joints in the suction pipe are air tight as well as
water tight. If the suction pipe can suck air, the pump will not be able to
pull water from the well.
1. Bolt pump to solid, level foundation.
2. Support all piping connected to the pump.
3. Wrap 1-1/2 to two layers of PTFE pipe thread sealant tape clockwise (as
you face end of pipe) on all male threads being attached to pump.
4. Tighten joints hand tight plus 1-1/2 turns. Do not overtighten.
NOTICE: Install pump as close to well head as poss ible. Long piping runs
and many fittings create friction and reduce flow.
NOTICE: For long horizontal pipe runs, install a priming tee between
check valve and well head as shown in Figure 6. For driven point
installations, install a check valve as shown in Figure 6. Be sure check
valve flow arrow points toward pump.
Use schedule 80 or iron pipe. See “Well Pipe In stalla tion” for more
information.
Figure 8 – Bolt Pump Down
P
532 1193
Figure 9 – Independently Support All
Piping Attached to Pump
P
530 1193
Figure 10 – Use PTFE pipe thread sealant tape on pipe
joints and connections to pump.
No air leaks In
Suction pipe.
If air flows
water won’t
Use PTFE tape.
Use PTFE pipe thread sealant tape or pipe joint
compound approved for use on PVC.
Figure 11 – Don’t overtighten.
748 0993
Don’t Hit
Thread Stops
Don’t
Overtighten
F
rom
Well
Pump
Body
Hand Tight Plus 1-1/2 Turns With Wrench.
Electrical 7
Connection diagram for dual voltage, single-phase motors. Your dual-
voltage motor’s terminal board (under the motor end cover) will match one
of the diagrams below. Follow that diagram if necesary to convert motor to
115 Volt power.
Connect power supply wires to L1 and L2. For 3-phase motors, or if motor
does not match these pictures, follow the connection diagram on the motor
nameplate.
Hazardous voltage. Can shock, burn, or cause death.
Disconnect power to motor before working on pump or motor. Ground
motor before con necting to power supply.
THE MOTOR IS SET FOR
230 VOLTS WHEN SHIPPED.
To change the motor to use 115 volts:
1. Turn off power
2. Remove the back motor cover.
3. Use a screwdriver or 1/2” wrench and turn the voltage selector dial
counterclockwise until 115 shows in the dial opening.
4. Reinstall the motor cover.
WIRING
Ground motor before connecting to electrical power supply. Failure to
ground motor can cause severe or fatal electrical shock hazard.
Do not ground to a gas supply line.
To avoid dangerous or fatal electrical shock, turn OFF power to motor
before working on electrical connections.
Supply voltage must be within ±10% of nameplate voltage. Incorrect
voltage can cause fire or damage motor and voids warranty. If in doubt
consult a licensed electrician.
Use wire size specified in Wiring Chart (Page 8). If possible, connect
pump to a separate branch circuit with no other appliances on it.
Wire motor according to diagram on motor nameplate. If nameplate
diagram differs from diagrams above, follow nameplate diagram.
Figure 12 - Changing the Voltage
Setting
Figure 13 – Motor Set for 115 Volt
Operation
Electrical 8
1. Install, ground, wire and maintain this pump in accordance with
electrical code requirements. Consult your local building inspector for
information about codes.
2. Provide a correctly fused disconnect switch for protection while
working on motor. Consult local or national electrical codes for switch
requirements.
3. Disconnect power before servicing motor or pump. If the disconnect
switch is out of sight of pump, lock it open and tag it to prevent
unexpected power appli cation.
4. Ground the pump permanently using a wire of the same size as that
specified in wiring chart (below). Make ground connection to green
grounding term inal under motor canopy marked GRD. or .
5. Connect ground wire to a grounded lead in the service panel or to a
metal underground water pipe or well casing at least 10 feet long. Do
not connect to plastic pipe or insulated fittings.
6. Protect current carrying and grounding conductors from cuts, grease,
heat, oil, and chemicals.
7. Connect current carrying conductors to terminals L1 and L2 under
motor canopy. When replacing motor, check wiring diagram on motor
nameplate against Figure 12. If the motor wiring diagram does not
match either diagram in Figure 12, follow the dia gram on the motor.
IMPORTANT: 115/230 Volt single phase models are shipped from factory
with motor wired for 230 volts. If power supply is 115 volts, remove motor
canopy and reconnect motor as shown in Figure 12. Do not try to run
motor as received on 115 volt current.
8. Motor has automatic internal thermal overload protection. If motor has
stopped for unknown reasons, thermal overload may restart it unex-
pectedly, which could cause injury or property damage. Disconnect
power before servicing motor.
9. If this procedure or the wiring diagrams are con fusing, consult a
licensed electrician.
Wiring Chart – Recommended Wire and Fuse Sizes
Branch
DISTANCE IN FEET(METERS) FROM MOTOR TO SUPPLY
Max.
Fuse
0 - 100 101 - 200 201 - 300 301 - 400 401 - 500
Motor
Load
Rating
(0 - 30) (31 - 61) (62 - 91) (92 - 122) (123 - 152)
Model HP Volts Amp Amp AWG WIRE SIZE (mm
2
)
BPDH10-L 1 115/230 14.8/7.4 20/15 12/14(3/2) 8/14(8.4/2) 6/14(14/2) 6/12(4/3) 4/10(21/5.5)
BPDH15-L 1-1/2 115/230 19.2/9.6 25/15 10/14(5.5/2) 8/14(8.4/2) 6/12(14/3) 4/10(21/5.5) 4/10(21/5.5)
BPDH20-L 2 115/230 24.0/12.0 30/15 10/14(5.5/2) 6/14(14/2) 6/12(14/3) 4/10(21/5.5) 4/10(21/5.5)
BPDH25-L 2-1/2 115/230 26.0/12.0 30/15 8/14(8.4/2) 6/14(14/2) 6/12(14/3) 4/10(21/5.5) 4/10(21/5.5)
Operation 9
PRIMING THE PUMP
NOTICE: ‘Priming’ refers to the pump expelling all air in the system and
beginning to move water from its source out into the system. It does not
refer only to pouring water into the pump (although pouring water in is
usually the first step).
NOTICE: NEVER run pump dry. Running pump with out water in it will
damage seals and can melt impeller and diffuser. To prevent damage, fill
pump with water before starting.
1. Remove priming plug (Figure 14).
2. Make sure suction and discharge valves and any hoses on discharge side
of pump are open.
3. Fill pump and suction pipe with water.
4. Replace priming plug, using PTFE pipe thread sealant tape on thread;
tighten plug.
NOTICE: If a priming tee and plug have been provided for a long
horizontal run, be sure to fill suction pipe through this tee and replace
plug. (Don’t forget to tape the plug.)
5. Start pump: water should be produced in 10 minutes or less, the
time depending on depth to water (not more than 20') and length of
horizontal run (10' of horizontal suction pipe = 1' of vertical lift due to
friction losses in the pipe).
If no water is produced within 10 minutes, stop pump, release all
pressure, remove priming plug, refill and try again.
Hazardous pressure and risk of ex plo sion and scalding. If
pump is run con ti nu ously at no flow (that is, with discharge shut off or
without priming), water may boil in pump and piping system. Under
steam pressure, pipes may rupture, blow off of fittings or blow out of
pump ports and scald anyone near.
To prevent explosion, do the following:
A. Be sure discharge (valve, pistol grip hose nozzle, etc.) is open whenever
pump is running.
B. If pump fails to produce water when attempting to prime, release
all pressure, drain pump and refill with cold water after every two
attempts.
C. When priming, monitor pump and piping tempera ture. If pump or
piping begin to feel warm to the touch, shut off pump and allow system
to cool off. Release all pressure in system and refill pump and piping
with cold water.
619 1293
Figure 14 – Remove Priming Plug
P
618 1293
Figure 15 – Fill Pump Before Starting
Figure 16 – Run Ten Minutes or Less
1117 0993
Figure 17 – Do Not Run Pump with
Discharge Shut-off
Maintenance 10
MAINTENANCE
Pump and piping need not be disconnected to repair or replace motor or
seal (see Figure 19). If motor is replaced, replace the shaft seal. Keep one
on hand for future use.
Be sure to prime pump before starting.
NOTICE: Check motor label for lubrication instructions. The mechanical
shaft seal in the pump is water lubricated and self-adjusting.
NOTICE: Drain pump when disconnecting from service or when it might
freeze.
PUMP DISASSEMBLY
1. Disconnect power to motor.
NOTICE: Mark wires for correct assembly.
2. Remove clamp (see Figure 19).
3. Remove pump base mounting bolts. Motor assembly and back half of
pump can now be pulled away from pump front half (Figure 19).
CAREFULLY remove O-ring.
CLEANING/REPLACING IMPELLER
NOTICE: First, follow instructions under “Pump Dis assembly”.
1. Remove four screws fastening diffuser to seal plate; remove diffuser (see
Figure 20). Exposed impeller can now be cleaned.
2. If impeller must be replaced, loosen two machine screws and remove
motor canopy (see Figure 21).
3.
Capacitor voltage may be hazardous. To discharge
capacitor, hold insulated handle screwdriver BY THE HANDLE and
short capacitor terminals together (see Figure 21). Do not touch metal
screwdriver blade or capacitor terminals. If in doubt, consult a qualified
electrician.
4. Unscrew capacitor clamp and remove capacitor. Do not disconnect
capacitor wires to motor.
5. Slide 7/16" open end wrench in behind spring loaded switch on
motor end of shaft; hold motor shaft with wrench on shaft flats and
unscrew impeller by turning counterclockwise when looking into eye of
impeller.
6. To reinstall, reverse steps 1 through 5.
7. See directions under “Pump Reassembly,” Page 12.
REMOVING OLD SEAL
1. Follow instructions under “Pump Disassembly”.
2. Follow steps 2 through 5 under “Cleaning/Replacing Impeller”.
3. Unscrew four nuts holding pump back half to motor. Remove rotating
half of seal by placing two screwdrivers under back half of pump body
and carefully prying up (Figure 22). Back half of pump body will slide
off shaft, bringing seal with it.
Figure 20 – Remove Diffuser
753 0993
754 0993
Figure 22 – Remove Seal plate
548 1193
Figure 18 – Disconnect Power
Figure 19 – Slide Motor Back
739 0993
Figure 21 – Hold Shaft
To avoid electrical
shock hazard, use
insulated-handle
screwdriver to short
capacitor terminals
as shown.
739 0993
Maintenance 11
NOTICE: Be sure you do not scratch or mar shaft; if shaft is marred,
it must be dressed smooth with fine emery or crocus cloth before
installing new seal. DO NOT reduce shaft diameter!
4. Place pump body half face down on flat surface and tap out stationary
half of seal (see Figure 23).
INSTALLING NEW SEAL
1. Clean seal cavity in seal plate.
2. Wet outer edge of Rubber Cup on ceramic seat with liquid soap.
Be sparing!
3. Put clean cardboard washer on seal face. With thumb pressure, press
ceramic seal half firmly and squarely into seal cavity (See Figure 24).
Polished face of ceramic seat is up. If seal will not seat correctly,
remove, placing seal face up on bench. Reclean cavity. Seal should
now seat correctly.
4. If seal does not seat correctly after recleaning cavity, place a cardboard
washer over polished seal face and carefully press into place using a
piece of standard 3/4" pipe as a press.
NOTICE: Be sure you do not scratch seal face.
5. Dispose of cardboard washer and recheck seal face to be sure it is free
of dirt, foreign particles, scratches and grease.
6. Inspect shaft to be sure it is free of nicks and scratches.
7. Reassemble pump body half to motor flange. BE SURE it is right
side up.
8. Apply liquid soap sparingly (one drop is sufficient) to inside diameter of
rotating seal member.
9. Slide rotating seal member (carbon face first) onto shaft until rubber
drive ring hits shaft shoulder.
NOTICE: Be sure not to nick or scratch carbon face of seal when passing it
over threaded shaft end or shaft shoulder. The carbon surface must remain
clean or short seal life will result.
10. Hold motor shaft with 7/16" open end wrench on shaft flats and screw
impeller onto shaft. Be sure you do not touch capacitor terminals with
body or any metal object. Tightening impeller will automatically locate
seal in correct position.
11. Remount diffuser on pump body half with five screws.
12. Follow instructions under “Pump Reassembly”.
755 0993
Figure 23 – Tap Out Seal
477 0194
Figure 24 – Press in New Seal
1072 0697
Ceramic
Face
Carbon
Face
Be Careful That
Motor Shaft Shoulder...
...Does Not Damage
Seal Face
Figure 25 – Protect Seal Faces
739 0993
Figure 26 – Hold Shaft
To avoid electrical
shock hazard, use
insulated-handle
screwdriver to short
capacitor terminals
as shown.
739 0993
Maintenance 12
PUMP REASSEMBLY
1. Clean O-ring and O-ring groove.
2. Put O-ring in groove on face of flange; put pump halves together (see
Figure 27).
3. BE SURE inside of clamp is clean. Place clamp on pump halves; snug
up. Alternately tighten screw and tap clamp with mallet to seat O-ring
(see Figure 28).
4. Replace base mounting bolts.
5. Replace pressure switch tubing and motor wiring; close draincock.
6. Prime pump according to instructions. See “Opera tion.”
7. Check for leaks.
617 1293
Figure 27 – Assemble Pump
Figure 28 – Tap Clamp While
Tightening
621 1293
Troubleshooting 13
* (Note: Stop pump;
then check prime
before looking
for
other causes.
Unscrew
priming
plug and see if water
is in priming hole).
SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION
Motor will not run Disconnect switch is off Be sure switch is on.
Fuse is blown or circuit breaker tripped Replace fuse or reset circuit breaker.
Starting switch is defective DISCONNECT POWER; Replace starting switch.
Wires at motor are loose, Refer to instructions on wiring (Page 7). DISCONNECT POWER; check and
disconnected, or wired incorrectly tighten all wiring.
Capacitor voltage may be hazardous. To discharge
capacitor, hold insulated handle screwdriver BY THE HANDLE and
short capacitor terminals together. Do not touch metal screwdriver
blade or capacitor terminals. If in doubt, consult a qualified electrician.
Motor runs hot and Motor is wired incorrectly Refer to instructions on wiring.
overload kicks off
Voltage is too low Check with power company. Install heavier wiring if wire size is too small
(See Electrical / Wiring Chart).
Motor runs but no Pump in new installation did In new installation:
water is delivered* not pick up prime through:
1. Improper priming 1. Re-prime according to instructions.
2. Air leaks 2. Check all connections on suction line, with soapy water or
shaving cream.
3. Leaking foot valve or check valve 3. Replace foot valve or check valve.
Pump has lost prime through: In installation already in use:
1. Air leaks 1. Check all connections on suction line and shaft seal.
2. Water level below suction pipe inlet 2. Lower suction line into water and re-prime. If receding water level
in well exceeds 25’ (7.6M), a deep well pump is needed.
Foot valve or strainer is plugged Clean foot valve or strainer.
Impeller is plugged Clean impeller.
Check valve or foot valve is stuck shut Replace check valve or foot valve.
Pipes are frozen Thaw pipes. Bury pipes below frost line. Heat pit or pump house.
Foot valve and/or strainer are Raise foot valve and/or strainer above bottom of water source.
buried in sand or mud Clean foot valve and strainer.
Water level is too low for shallow well Pump will not lift water more than 25 feet.
setup to deliver water
Pump does not Water level in well is lower than A deep well jet will be needed if your well is more than 25’ (7.6M)
deliver water to full estimated depth to water.
capacity
Steel piping (if used) is corroded or Replace with plastic pipe where possible, otherwise with new steel pipe.
limed, causing excess friction
Piping is too small in size Use larger piping.
Packed well point Backflush well point or sink new point.
Repair Parts 14
L
1
7
6
-
3
5
P
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
15
16
16
17
527 1193
Exploded View
BPDH10-L
BPDH15-L
REPAIR PARTS LIST
Key Part No. BPDH10-L BPDH15-L
No. Description Used 1 HP 1-1/2 HP
1 Motor 1 A100EHL A100FHL
2 Water Slinger 1 C69-2 C69-2
3 Priming Plug 1 WC78-39T WC78-39T
4 Pump Body Back Half (Complete) 1 L176-47P1 L176-47P1
5 O-Ring 1 U9-399 U9-399
6 Shaft Seal for 5/8" Shaft 1 U109-6A U9-410
7 Impeller 1 C105-92PVB C105-92PBBB
8 Diffuser 1 C1-258PCA C1-258PCA
9 Screw - #8 - 32 RH 4 U30-997SS U30-997SS
10 "V" Clamp 1 C19-54SS C19-54SS
11 Tank Body Front Half (Complete) 1 C176-66P C176-66P
12 Drain Plug - 1/4 NPT 1 WC78-40T WC78-40T
13 O-Ring 1 U9-226 U9-226
14 Base 1 C4-42P C4-41P
15 Washer - 5/16 4 U43-11ZP U43-11ZP
16 Nut - 5/16 - 18 4 U36-37ZP U36-37ZP
17 Rubber Pad 1 C35-11 C35-11
• Owner’sManual 1 BE190 BE190
•Notillustrated.
REPAIR PARTS LIST
•Notillustrated.
Key Part No. BPDH20-L BPDH25-L
No. Description Used 2 HP 2-1/2 HP
1 Motor 1 A100GLL AE100G5LL
2 Water Slinger 1 C69-2 C69-2
3 Tank Body Back Half 1 C3-189P1 C3-189P1
4 O-Ring 1 U9-228A U9-228A
5 Shaft Seal for 5/8" Shaft 1 U109-6A U109-6A
6 Impeller 1 C105-214PFA C105-214PGA
• ImpellerScrew 1 C30-51SS C30-51SS
7 Diffuser 1 C1-274P C1-274P
8 Screw - #8 - 32 RH 2 U30-542SS U30-542SS
9 "V" Clamp 1 C19-37A C19-37A
10 Tank Body Front Half (Complete)
(Includes Key Nos. 12 and 13) 1 C176-62P C176-62P
11 Priming Plug 1 WC78-39T WC78-39T
12 Drain Plug - 1/4 NPT 1 WC78-40T WC78-40T
13 O-Ring 1 U9-393 U9-393
14 Base 1 C4-42P C4-41P
15 Washer - 5/16 2 U43-42SS U43-42SS
16 Capscrew 2 U30-77SS U30-778SS
17 Rubber Pad 1 C35-11 C35-11
18 Capscrew 2 U30-74SS U30-90SS
• Owner’sManual 1 BE190 BE190
Repair Parts 15
1
2092 1095
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Exploded View
BPDH20-L
BPDH25-L
This page intentionally left blank
293 WRIGHT STREET, DELAVAN, WI 53115 WWW.BERKELEYPUMPS.COM
PH: 888-782-7483
noTICe D’uTIlIsaTIon
Pompe centrifuge à amorçage
automatique résistant à la corrosion
© 2013 Pentair, Ltd. All Rights Reserved. BE190 (Rév. 22/02/13)
L
1
7
6
-
3
5
P
3774 1000
BPD
Installation/Fonctionnement/Pièces
Pour plus de renseignements concernant l’utilisation, l’installation ou l’entretien,
Composer le 1 (888) 782-7483
Sécurité 2
LIRE TOUTES CES INSTRUCTIONS
ET LES SUIVRE!
Ce symbole indique qu'il faut être prudent.
Lorsque ce symbole apparaît sur la pompe ou dans
cette Notice, rechercher une des mises en garde qui
suivent, car elles indiquent un potentiel possible de
blessures corporelles :
avertit d'un danger qui causera des blessures
corporelles, la mort ou des dommages matériels importants
si on l'ignore.
AVERTISSEMENT
avertit d'un danger qui risque de causer des
blessures corporelles, la mort ou des dommages matériels
importants si on l'ignore.
avertit d'un danger qui causera ou qui
risquera de causer des blessures corporelles, la mort ou des
dommages matériels importants si on l'ignore.
Le mot NOTA indique des instructions spéciales et
importantes n'ayant aucun rapport avec les dangers.
Lire attentivement toutes les consignes de sécurité
contenues dans cette Notice ou collées sur la pompe.
Garder les autocollants de sécurité en bon état; les
remplacer s'ils manquent ou s'ils ont été endommagés.
Avertissement lié à la Proposition 65 de la Californie
AVERTISSEMENT
Ce produit et les accessoires connexes
contiennent des produits chimiques reconnus dans l’État
de la Californie comme pouvant provoquer des cancers,
des anomalies congénitales ou d’autres dangers relatifs à la
reproduction.
SÉCURITÉ CONCERNANT
L’ÉLECTRICITÉ
Câbler le moteur en
fonction de la bonne
tension. Voir la Section «
Électricité » de cette
Notice et la plaque
signalétique du moteur.
Mettre à la terre le
moteur avant de le
brancher sur le courant
électrique.
Conforme au Code
national de l’électricité,
au Code canadien de
l’électricité et aux codes
municipaux pour tous les
câblages.
Respecter les instructions
de câblage figurant dans
cette Notice lorsque l’on
branche le moteur sur une
ligne haute tension.
Empêcher les enfants d'accéder à l'atelier en posant des
cadenas, un interrupteur général et en déposant les clés des
démarreurs.Empêcher les enfants d'accéder à l'atelier en posant
des cadenas, un interrupteur général et en déposant les clés des
démarreurs.
Ne pas toucher un moteur qui fonctionne.
Les moteurs modernes sont conçus pour fonctionner par
des températures élevées. Pour ne pas se brûler lorsque l’on
interviendra sur la pompe, la laisser refroidir pendant 20
minutes après l’avoir arrêtée avant de la toucher.
SÉCURITÉ GÉNÉRALE
La pompe n’est conçue que pour les arroseurs de pelouse. Pour
éviter toute accumulation de chaleur, risque de surpression
et des blessures possibles, ne pas utiliser avec un système à
réservoir sous pression (eau domestique). Ne pas utiliser en
tant que pompe de surpression; l’aspiration sous pression peut
causer l’explosion du corps de la pompe.
Ne pas laisser geler la pompe ou les tuyauteries. Le gel risque
d’endommager la pompe et les tuyauteries, ce qui peut causer
des blessures et annulera la garantie.
Ne pomper que de l’eau avec cette pompe.
Périodiquement, inspecter la pompe et tous les éléments du
système.
Toujours porter des lunettes de sécurité lorsque l’on intervient
sur une pompe.
Garder la zone de travail propre, non encombrée et bien
éclairée; tous les outils et tout l’équipement non utilisés doivent
être entreposés correctement.
Ne pas laisser les visiteurs s’approcher de la zone de travail.
Pression dangereuse! Ne
pas faire fonctionner la
pompe si le refoulement est
fermé.
Dissiper toute la pression du
système avant d’intervenir sur
un élément.
Tension dangereuse.
Risque de secousses
électriques, de brûlures,
voire de mort.
Mettre à la terre la pompe
avant de la brancher sur le
courant électrique.
Garantie limitée
BERKELEY garantit au consommateur initial (ci-après appelé l’« Acheteur ») que les produits énumérés dans les présentes sont exempts de
défaut de matériau et de fabrication pendant la durée des garanties à compter de la durée des garanties indiquées ci-dessous.
Produits Durée des garanties
Systèmes d’eau :
Produits de systèmes d’eau — Pompes à éjecteur, petites pompes centrifuges, pompes
submersibles et tous les accessoires connexes
Selon le premier terme atteint :
12 mois à compter de la date de la première installation ou
18 mois à compter de la date de fabrication
Réservoirs composites Pro-Source™ 5 ans à compter de la date de la première installation
Réservoirs sous pression en acier Pro-Source™ 5 ans à compter de la date de la première installation
Réservoirs revêtus d’époxyde Pro-Source™ 3 ans à compter de la date de la première installation
Produits de puisard/d’égout/d’effluents
12 mois à compter de la date de la première installation ou
18 mois à compter de la date de fabrication
Agricole/commercial:
Centrifuges – entraînement par moteur monobloc, monté sur cadre, monté sur SAE,
entraînement par moteur à combustion, multiétagé vertical, SSCX, SSHM, pompes
pour les matières solides, pompes submersibles pour les matières solides
12 mois à compter de la date de la première installation ou
24 mois à compter de la date de fabrication
Turbines submersibles, diamètre de 6po et plus grand
12 mois à compter de la date de la première installation ou
24 mois à compter de la date de fabrication
Nos garanties limitée ne s’appliquent pas aux produits ayant fait l’objet de négligence, d’une mauvaise utilisation, d’une mauvaise
installation ou d’un manque d’entretien adéquat. Sans aucune limitation des présentes, la garantie des moteurs triphasés submersibles
sera nulle et non avenue si ces moteurs sont branchés et fonctionnent sur le courant monophasé par l’intermédiaire d’un déphaseur. Il faut
également noter que les moteurs triphasés doivent être protégés par un relais de surcharge tripolaire thermocompensé à déclenchement
extrêmement rapide du calibre recommandé, sinon la garantie sera nulle et non avenue.
Le seul recours de l’Acheteur et la seule responsabilité de BERKELEY consistent à réparer ou à remplacer (au choix de BERKELEY) les
produits qui se révéleraient défectueux. L’Acheteur s’engage à payer tous les frais de main d’œuvre et d’expédition du produit couvert par
sa garantie et de s’adresser au concessionnaire-installateur ayant procédé à l’installation dès qu’un problème est découvert pour obtenir
un service sous garantie. Aucune demande de service en vertu de sa garantie ne sera acceptée après expiration de la durée de sa garantie.
Ces garanties ne sont pas transférables.
BERKELEY DÉCLINE TOUTE RESPONSABILITÉ POUR TOUT DOMMAGE INDIRECT OU FORTUIT QUEL QU’IL SOIT.
LA GARANTIE LIMITÉE SUSMENTIONNÉE EST EXCLUSIVE ET REMPLACE TOUTES LES AUTRES GARANTIES EXPRESSES ET TACITES, Y
COMPRIS, MAIS SANS S’Y LIMITER, LES GARANTIES DE QUALITÉ MARCHANDE ET D’ADAPTATION À UN USAGE PARTICULIER. LA
GARANTIE LIMITÉE SUSMENTIONNÉE NE DOIT PAS ÊTRE PROLONGÉE AU-DELÀ DE LA DURÉE PRÉVUE AUX PRÉSENTES.
Certains états, territoires et certaines provinces ne permettent pas l’exclusion ou la limitation des dommages indirects ou fortuits, ni les
limitations relatives à la durée des garanties tacites. Par conséquent, il se peut que les limitations ou les exclusions stipulées dans les
présentes ne s’appliquent pas dans ce cas. Ces garanties accordent des droits juridiques précis, bien que l’on puisse bénéficier d’autres
droits, selon la province, le territoire ou l’état dans lequel on réside.
La présente garantie limitée est entrée en vigueur le 1er juin 2011 et remplace toute garantie non datée ou antérieure à cette date.
Aux États-Unis : BERKELEY, 293 Wright St., Delavan, WI 53115
Au Canada : 269 Trillium Dr., Kitchener, Ontario N2G 4W5
Table des matières 3
Merci d'avoir acheté une pompe de qualité supérieure mise à l'essai à l'usine.
Pages
Sécurité générale .................................................................................................2
Garantie...............................................................................................................3
Installation ...............................................................................................De 4 à 6
Électricité .........................................................................................................7, 8
Fonctionnement ................................................................................................... 9
Entretien ..............................................................................................De 10 à 12
Recherche des pannes .......................................................................................13
Pièces de rechange ...................................................................................14 et 15
Installation 4
AVANT D’INSTALLER LA POMPE
NOTA : La profondeur du puits jusqu’au niveau de l’eau ne doit pas être supérieure
à 20 pieds (6 mètres).
1. De grandes longueurs de tuyaux et de nombreux raccords augmentent le
frottement et réduisent le débit. Positionner la pompe aussi près que possible
du puits. Dans la mesure du possible, utiliser le moins possible de coudes et de
raccords.
2. S’assurer que le puits est débarrassé de sable. Le sable bouchera la pompe, ce
qui annulera la garantie.
3. Protéger la pompe et toutes les tuyauteries contre le gel. Le gel fera éclater
les tuyauteries, endommagera la pompe, ce qui annulera la garantie. Vérifier
localement quelles sont les conditions requises pour protéger contre le gel
(habituellement, les tuyaux doivent être enterrés à 30 cm (12 pouces) plus bas
que la profondeur maximum du gel et la pompe doit être isolée).
4. S’assurer que toutes les tuyauteries et que le clapet de pied sont propres et en
bon état.
5. Il ne doit y avoir aucune poche d’air dans le tuyau d’aspiration.
6. Il ne doit y avoir aucune prise d’air dans le tuyau d’aspiration. Utiliser du ruban
d’étanchéité en PTFE pour filetage sur les raccords de tuyaux filetés.
7. Des raccords unions installés près de la pompe et du puits faciliteront l’entretien.
Prévoir suffisamment de place pour pouvoir utiliser des clés à tuyau.
8.
AVERTISSEMENT
Le corps de la pompe risque d’exploser si cette pompe est
utilisée conjointement avec une pompe de surpression. NE PAS utiliser cette
pompe sur une installation fonctionnant déjà avec une pompe de surpression.
NOTA : En fonction du type de puits, utiliser la méthode d’installation suivante :
1100 0697
Figure 2 – Le clapet de pied doit
fonctionner librement
L’aspiration des modèles BPDH10-L et BPDH15-L est de 2 pouces NPT et leur refoulement est de 1 1/2 po NPT.
L’aspiration et le refoulement des modèles BPDH20-L et BPDH25-L sont de 2 po NPT.
TABLEAU DES RENDEMENTS (en litres par minute) – Pression de refoulement élevée
BPDH10-L BPDH15-L BPDH20-L BPDH25-L
Refoul- Distance au-dessus de l’eau
ement
1,5m 3m 4,6m 6,1m 1,5m 3m 4,6m 6,1m 1,5m 3m 4,6m 6,1m 1,5m 3m 4,6m 6,1m
lb/po
2
Débit de la pompe en l/min
10 208 185 182 170 254 231 212 174 261 254 246 235 348 314 307 295
15 193 174 170 167 250 220 208 170 246 238 227 220 326 299 295 288
20 170 159 148 140 231 212 204 167 223 212 204 197 303 288 284 280
25 144 132 121 110 208 197 193 163 197 189 182 170 276 269 265 261
30 114 106 91 76 182 170 167 144 178 170 159 151 250 250 246 242
35 87 72 61 42 148 140 129 106 159 144 132 121 227 227 223 220
40 64 49 30 125 102 76 42 129 114 102 87 208 204 201 197
45 68 53 30 95 64 38 178 174 174 170
50 53 26 151 144 140 136
Figure 1 – Aucune saleté ni tartre dans
le tuyau d’aspiration
1096 0697
Pump
Body
From
Well
Dirt and Scale Plug Pump and Pipes!
Use New Pipe for Best Results.
Clean Flow!
Les saletés et le sable boucheront les
orifices et les tuyaux!
Pour obtenir les meilleurs résultats
possibles, n’utiliser que des tuyaux neufs.
Corps
de la
pompe
Débit sans
obstruction!
En provenance
du puits
Figure 3 – Aucune poche d’air dans le
tuyau d’aspiration
No Sags
Sags Allow Air Pockets
If Air Pockets Form, Water Won’t Flow.
Keep Pipe Straight and Angled up to Pump.
1101 0697
Pas d’affaissement
Les affaissements favoriseront la formation de
poches d’air. Si des poches d’air se forment,
l’eau ne circulera pas.
Garder le tuyau droit et légèrement incliné
vers la pompe.
Figure 4 – Le tuyau d’aspiration ne
doit pas aspirer d’air
No air leaks In
Suction pipe.
If air flows
water won’t
Use PTFE tape.
Use PTFE pipe thread sealant tape or pipe joint
compound approved for use on PVC.
Utiliser du ruban d’étanchéité en PTFE pour filetage sur
les raccords de tuyaux filetés en PVC.
Aucune prise d’air dans
le tuyau d’aspiration.
En cas de prise d’air,
l’eau ne circulera pas
Utiliser du ruban d’étanchéité en PTFE pour filetage
sur les raccords de tuyaux filetés.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Berkeley BPD Series Corrosion Resistant Self-Priming Centrifugal Pump Le manuel du propriétaire

Catégorie
Pompes à eau
Taper
Le manuel du propriétaire
Ce manuel convient également à