Tripp Lite DC-to-AC Inverter Le manuel du propriétaire

Catégorie
Adaptateurs secteur
Taper
Le manuel du propriétaire
Owner’s Manual
Quiet Mobile Power
Congratulations! You've purchased the most advanced, feature-rich Inverter/Charger designed for recreational applications. Tripp Lite
PowerVerter Inverter/Chargers are the quiet alternative to generators—with no fumes, fuel or noise to deal with! You get AC electricity
anywhere and anytime you need it: away from shore power, rolling down the highway, dry camping in majestic back country or overnighting
at a non-electric site. Your Tripp Lite Inverter/Charger provides your appliances, equipment and electronics with utility- or generator-supplied
AC electricity (filtered through premium ISOBAR
®
surge protection) whenever available. In addition, it automatically powers your craft's 12V
system and recharges your connected battery bank—doing what traditional converter/chargers do. Whenever power blackouts, brownouts or
high voltages occur, your Inverter/Charger automatically switches over to inverting battery output to power connected AC equipment.
Better for Your Equipment Premium Protection Levels
Built-In ISOBAR
®
Surge Protection
Automatic Overload Protection
Ideal Output for All Loads
Frequency-Controlled Output
Automatic Load Switching
Balanced Load Sharing
Better for Your Batteries Faster Battery Recharge
High-Amp, 3-Stage Battery Charger (adjustable)
Critical Battery Protection
Battery Charge Conserver (Load Sense)
Battery Temperature Sensing
High-Efficiency DC-to-AC Inversion
Better for You Quiet, Simple, Maintenance-Free Operation
Multi-Function Lights & Switches
Automatic Generator Starting
Moisture-Resistant Construction*
Safety 2
Feature Identification 3
Operation 4-5
Configuration 5-7
Battery Selection 8
Mounting 9
Battery Connection 10
AC Input/Output Connection 11
Service/Maintenance 11
Troubleshooting 12
Warranty/Warranty Registration 12
Français 13
PowerVerter
®
DC-to-AC
Inverter/Charger
Input Output
Invert: 12 VDC 120V, 60 Hz. AC
Charge: 120V, 60 Hz. AC 12 VDC
1111 W. 35th Street, Chicago, IL 60609 USA
Customer Support: (773) 869-1234
www.tripplite.com
* Inverter/Chargers are moisture-resistant, not waterproof.
Copyright © 2007. All rights reserved. PowerVerter
®
is a registered trademark of Tripp Lite.
Contents
WARRANTY
REGISTRATION
Register online today for
a chance to win a FREE Tripp Lite
product! www.tripplite.com/warranty
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS!
This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite
Inverter/Chargers.
Location Warnings
Although your Inverter/Charger is moisture resistant, it is NOT waterproof. Flooding the unit with water will cause it to short circuit
and could cause personal injury due to electric shock. Never immerse the unit, and avoid any area where standing water might
accumulate. Mounting should be in the driest location available.
Leave a minimum of 2" clearance at front and back of the Inverter/Charger for proper ventilation. To avoid automatic Inverter/Charger
shutdown due to overtemperature, any compartment that contains the Inverter/Charger must be properly ventilated with adequate
outside air flow. The heavier the load of connected equipment, the more heat will be generated by the unit.
Do not mount unit with its front or rear panel facing down (at any angle). Mounting in this manner will seriously inhibit the
unit's internal cooling, eventually causing product damage not covered under warranty.
Do not install the Inverter/Charger directly near magnetic storage media, as this may result in data corruption.
Do not install near flammable materials, fuel or chemicals.
Battery Connection Warnings
Multiple battery systems must be comprised of batteries of identical voltage, age, amp-hour capacity and type.
Because explosive hydrogen gas can accumulate near batteries if they are not kept well ventilated, your batteries should not be
installed (whether for a mobile or stationary application) in a “dead air” compartment. Ideally, any compartment would have some
ventilation to outside air.
Sparks may result during final battery connection. Always observe proper polarity as batteries are connected.
Do not allow objects to contact the two DC input terminals. Do not short or bridge these terminals together. Serious personal injury
or property damage could result.
Equipment Connection Warnings
Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the
failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this
equipment in the presence of a flammable anesthetic mixture with air, oxygen or nitrous oxide.
You may experience uneven performance results if you connect a surge suppressor, line conditioner or UPS system to the output of
the Inverter/Charger.
Tripp Lite recommends wiring the AC output to a GFCI protector (ground fault circuit interrupter).
The main grounding lug should be connected to the vehicle chassis with an 8 AWG wire (minimum).
Operation Warnings
Your Inverter/Charger does not require routine maintenance. Do not open the device for any reason. There are no user serviceable parts inside.
Potentially lethal voltages exist within the Inverter/Charger as long as the battery supply and/or AC input are connected. During any
service work, the battery supply and AC input connection (if any) should therefore be disconnected.
Do not connect or disconnect batteries while the Inverter/Charger is operating in either inverting or charging mode. Operating Mode
Switch should be in the DC OFF position. Dangerous arcing may result.
Caution: These models have a failsafe AC pass-through feature where the AC output will be live (if AC input is
available) even though the operating mode switch is set to DC OFF.
Caution: If your Inverter/Charger is mounted in a location that lacks proper ventilation, the surface of the metal
enclosure could become hot. Allow to cool before touching. If the Inverter/Charger must be installed in a location
that lacks proper ventilation, mount the unit in such a way that the top of the metal enclosure will not be subjected
to accidental contact during operation.
3
Feature Identification
Identify the premium features on your specific model and quickly locate instructions on how to maximize their use.
Configuration DIP Switches: optimize Inverter/Charger
operation depending on your application. See Configuration
section for setting instructions.
Operating Mode Switch: controls Inverter/Charger operation.
The “AUTO/REMOTE” setting ensures your equipment
receives constant, uninterrupted AC power. It also enables the
Inverter/Charger to be remotely monitored and controlled with
an optional remote module (Tripp Lite model APSRM4, sold
separately). The “CHARGE ONLY” setting allows your batteries
to return to full charge faster by turning the inverter off which
halts battery discharging. The "DC OFF" setting de-energizes
the unit and connects AC OUT to AC IN. See Operation section
for setting instructions.
“LINE”, “INVERT”, “LOAD” LEDs: show whether the
Inverter/Charger is operating from AC line power or DC battery
power. It also warns you if the connected equipment load is too
high. See Operation section for instructions on reading the
indicator lights.
"BATT VOLTAGE" LEDs: these three lights will turn ON in
several sequences to show approximate battery level. See
Operation section for instructions on reading the indicator lights.
DC Power Terminals: connect to your battery terminals. See
Battery Connection section for instructions.
Hardwire AC Input/Output Terminals: securely connect the
Inverter/Charger to vehicle or facility electrical system input and
recommended GFCI protected output. See AC Input/Output
Connection section for instructions.
Resettable Circuit Breakers: protect your Inverter/Charger
against damage due to output overload or charger failure. See
Operation section for resetting instructions.
Remote Control Module Connector: allows remote monitoring
and control with an optional module (Tripp Lite model
APSRM4, sold separately). See remote module owners manual
for connection instructions.
Battery Charge Conserver (Load Sense) Dial: conserves
battery power by setting the low-load level at which the
Inverter/Charger’s inverter automatically shuts off. See
Configuration section for setting instructions.
Main Ground Lug: properly grounds the Inverter/Charger to
vehicle grounding system or to earth ground. See Configuration
section for instructions.
Multi-Speed Cooling Fan: quiet, efficient fan prolongs equipment
service life.
Hardwire AC Input/Output Cover Plate
Battery Temperature Sensing Connector: prolongs battery life
by adjusting charge based on battery temperature. Use with
cable (included on select models). See Configuration section for
details.
Automatic Generator Start Connector: automatically cycles
generator based on battery voltage. Use with user-supplied
cable. See Configuration section for details.
Ignition Switch Control Jack: use to connect the Inverter to
your vehicle's ignition switch (with user supplied cable) in order
to automatically control the Inverter with the vehicle's ignition
switch. See Operation section.
1
2
3
4
5
6
7
8
9
HOT IN
NEUTRAL IN
GROUND IN
GROUND OUT
HOT OUT
“FOR USE WITH COPPER WIRE ONLY”
NEUTRAL OUT
1
24 3
5
7
6
Front View
10
Rear View
Side Mounted,
Not Shown
Side Mounted,
Not Shown
10
11
12
13
11
8
9
13
14
12
14
Note: features and location may vary by model.
15
Side Mounted,
Not Shown
15
4
Operation
Switch Modes
After configuring, mounting and connecting your Inverter/Charger,
you are able to operate it by switching between the following
operating modes as appropriate to your situation:
AUTO/REMOTE: Switch to this mode when you
need constant, uninterrupted AC power for connected
appliances and equipment. The Inverter/Charger will
continue to supply AC power to connected equipment
and to charge your connected batteries while utility-
or generator-supplied AC power is present. Since the
inverter is ON (but in Standby) in this mode, it will automatically
switch to your battery system to supply AC power to connected
equipment in the absence of a utility/generator source or in
over/under voltage situations. “AUTO/REMOTE” also enables an
optional remote control module (Tripp Lite model APSRM4, sold
separately) to function when connected to the unit.
CHARGE ONLY: Switch to this mode when you
are not using connected appliances and equipment in
order to conserve battery power by disabling the
inverter. The Inverter/Charger will continue to
supply AC power to connected equipment and
charge connected batteries while utility- or generator-supplied AC
power is present. However, since the inverter is OFF in this mode, it
WILL NOT supply AC power to connected equipment in the
absence of a utility/generator source or in over/under voltage
situations.
DC OFF: Switch to this mode to prevent the inverter
from drawing power from the batteries. Use this
switch to automatically reset the unit if it shuts down
due to overload or overheating. First remove the
excessive load or allow the unit to sufficiently cool
(applicable to your situation). Switch to “DC OFF”, then back to
“AUTO/REMOTE” or “CHARGE ONLY” as desired. If unit fails to
reset, remove more load or allow unit to cool further and retry. Use
an optional remote control module (Tripp Lite model APSRM4, sold
separately) to reset unit due to overload and overtemperature.
CAUTION: The unit will always pass AC power through to
connected equipment if plugged into a live AC outlet, regardless
of the position of the Operating Mode Switch.
Indicator Lights
Your Inverter/Charger (as well as an optional Tripp Lite Remote
Control Module, sold separately) is equipped with a simple,
intuitive, user-friendly set of indicator lights that display a wide
variety of operating details.
“LINE Green LED”: If the operating mode switch
is set to “AUTO/REMOTE”, this light will
ILLUMINATE CONTINUOUSLY when your
connected equipment is receiving continuous AC
power supplied from a utility/generator source.
If the operating mode switch is set to “CHARGE ONLY”, this light
will BLINK to alert you that the unit’s inverter is OFF and will NOT
supply AC power in the absence of a utility/generator source or in
over/under voltage situations.
“INV” (Inverting) Yellow LED: This light will
ILLUMINATE CONTINUOUSLY whenever
connected equipment is receiving battery-supplied,
inverted AC power (in the absence of a
utility/generator source or in over/under voltage
situations). This light will be off when AC power is supplying the
load. This light will BLINK to alert you if the load is less than the
Battery Charge Conserver (Load Sense) setting.
“LOAD” Red LED: This red light will
ILLUMINATE CONTINUOUSLY whenever the
inverter is functioning and the power demanded by
connected appliances and equipment exceeds 100%
of load capacity. The light will BLINK to alert you
when the inverter shuts down due to a severe overload or
overheating. If this happens, turn the operating mode switch “DC
OFF”; remove the overload and let the unit cool. You may then turn
the operating mode switch to either “AUTO/REMOTE” or
“CHARGE ONLY” after it has adequately cooled. This light will be
off when AC power is supplying the load.
“BATT VOLTAGE” LEDs: If the operating mode switch is in the
"AUTO/REMOTE" or "Charge Only" position, the LEDs indicate
the approximate charge level and voltage of your connected battery
bank and alert you to several fault conditions. See Chart for charge
and voltage levels.
LED Function with Switch in “AUT
O/REMOTE” or
CHARGE ONLY” Position
Approximate Battery Charge Level*
LEDs Battery Capacity
Illuminated (Charging/Discharging)
Green 91%–Full
Green & Yellow 81%–90%
Yellow 61%–80%
Yellow & Red 41%–60%
Red 21%–40%
All three lights off 1%–20%
Flashing red 0% (Inverter
shutdown)**
* Charge levels listed are approximate. Actual conditions vary
depending on battery condition and load. ** Inverter shutdown protects battery against damage
due to excessive discharge.
Fault Condition
LEDs Fault
Illuminated Condition
All three lights Excessive discharge
flash slowly* (Inverter shutdown)
All three lights Overcharge (Charger
flash quickly** shutdown)
*Approximately ½ second on, ½ second off. See Troubleshooting section. Inverter shutdown
protects battery against damage due to excessive discharge.** Approximately ¼ second on, ¼
second off. Charger shutdown protects battery against damage due to overcharge. May also
indicate a battery charger fault exists. See Troubleshooting section.
DC
OFF
CHARGE
ONLY
AUTO/
REMOTE
DC
OFF
CHARGE
ONLY
AUTO/
REMOTE
DC
OFF
CHARGE
ONLY
AUTO/
REMOTE
1
2
3
4
5
6
7
1
2
1
2 3
4
5
6
7
1
2
5
Select Battery Type—REQUIRED
CAUTION: The Battery Type DIP Switch setting must
match the type of batteries you connect, or your batteries
may be degraded or damaged over an extended period of
time. See “Battery Selection” for more information.
Battery Type Switch Position
Gel Cell (Sealed) Battery Up
Wet Cell (Vented) Battery Down (factory setting)
A1A2A3A4
OUTPUT C/B 12A
B4 B3 B2 B1
A4 A3 A2 A1
Group B Dip Switches
Group A Dip Switches
Group A DIP Switches
Using a small tool, configure your Inverter/Charger by setting the four Group A DIP Switches (located on the front panel of your unit; see
diagram) as follows:
A1
Operation
(continued)
Resetting Your Inverter/Charger to Restore AC Power
Your Inverter/Charger may cease supplying AC power or DC charging power in order to protect itself from overload or to protect your
electrical system. To restore normal functioning:
Overload Reset: Switch operating mode switch to “DC OFF” and remove some of the connected electrical load (ie: turn off some of the
AC devices drawing power which may have caused the overload of the unit). Wait one minute, then switch operating mode switch back to
either “AUTO/REMOTE” or “CHARGE ONLY.”
Select Low AC Input Voltage
Point for Switching to Battery—
OPTIONAL*
Switch
Voltage Position
105V #A4 Up & #A3 Up
95V #A4 Up & #A3 Down
85V #A4 Down & #A3 Up
75V #A4 Down & #A3 Down
(factory setting)
A1A2A3A4
A1A2A3A4
A1A2A3A4
A1A2A3A4
A3
A4
* Most of your connected appliances and equipment will perform adequately when your Inverter/Chargers Low AC Voltage Input Point
(DIP Switches #3 and #4 of Group A are set to 95V. However, if the unit frequently switches to battery power due to momentary low
line voltage swings that would have little effect on equipment operation, you may wish to adjust these settings. By decreasing the Low
AC Voltage Point, you will reduce the number of times your unit switches to battery due to voltage swings.
Configuration
Set Configuration DIP Switches
Using a small tool, set the Configuration DIP Switches (located on the front panel, see diagram) to optimize Inverter/Charger operation
depending on your application.
Charger Inhibit
Function Switch Position
Charger Inhibited Up
Charger Enabled Down (factory setting)
A2
A1A2A3A4
6
Select Battery Charger-Limiting Points—OPTIONAL
“Most Limiting” (#B2 & #B1 Up):
Charger-limiting takes effect the moment
any 120V AC load is applied; charger
output falls gradually from full output at
no 120V load passing through to no output
at full load.
“Less Limiting” (#B2 Up & #B1 Down):
Charger-limiting begins when the
Inverter/Charger’s load reaches 33% of the
Inverter/Charger’s load rating. Charger
output falls gradually from full output at
33% of the Inverter/Charger’s load rating to about 40% of full output
at full load.
Configuration
(continued)
B1B2B3B4
B1B2B3B4
Group B DIP Switches
Select AC Sharing—OPTIONAL
Your Inverter/Charger features a high-output battery charger that can draw a significant amount of AC power from your utility source or
generator when charging at its maximum rate. If your unit is supplying its full AC power rating to its connected heavy electrical loads at the
same time as this high charging occurs, the AC input circuit breaker could trip, resulting in the complete shut off of pass-through utility power.
To reduce the chance of tripping this breaker, Inverter/Chargers may be set to automatically limit the charger output. This keeps the sum of the
unit’s AC load and charge power within the circuit breaker rating. This charger-limiting function has two settings, allowing you to reduce
the charger’s draw lower and lower, as needed, if the AC input circuit breaker keeps tripping under the normal AC loads of devices you have
connected downline from the unit. The figures show how to set your DIP Switches for charger-limiting.
B1
B2
Set Battery Charging Amps—OPTIONAL
Check the nameplate of your unit for the
available high- and low-charging amp
options. By setting on high charging, your
batteries will charge at maximum speed and
the 12V DC system loads of your RV will be
well supplied. When setting on low charging, you lengthen the life
of your batteries (especially smaller ones).
Battery Charger Switch Position
Low Charge Amps Up
High Charge Amps Down (factory setting)
CAUTION: When switching to the High Charge Amp setting, the user must ensure that the
amp hour capacity of their battery system exceeds the amperage of the High Charge Amp
setting or the batteries may be damaged or degraded.
Select Equalize Battery Charge—OPTIONAL
This DIP Switch is momentarily engaged
to begin the process of equalizing the
charge state of your battery’s cells by time-
limited overcharge of all cells. This can
extend the useful life of certain types of
batteries; consult with your battery’s manufacturer to determine if
your batteries could benefit from this process. The charge
equalization process is automatic; once started, it can only be
stopped by removing the input power.
Setting Procedure
Move to “Equalize” (DOWN) position for three seconds.
Move to “Reset” (UP) position and leave it there. This is the
factory default setting.
CAUTION: Do not leave DIP switch #B3 in the down position after beginning process. Battery
charge equalization should only be performed in strict accordance with the battery manufacturer’s
instructions and specifications.
Battery Charge Switch Position
Reset Up (factory setting)
Equalize Down—momentarily
B1B2B3B4
Reset
Equaliz
e
B1B2B3B4
B4
B3
(factory setting)
7
Set Battery Charge Conserver (Load Sense) Dial—OPTIONAL
In order to save battery power, the unit’s inverter automatically shuts off in the absence of any power demand from
connected equipment or appliances (the electrical load). When the unit detects a load, it automatically turns its inverter
function on. Users may choose the minimum load the Inverter/Charger will detect by adjusting the Battery Charge Conserver
Dial (see diagram). Using a small tool, turn the dial clockwise to lower the minimum load that will be detected, causing the
inverter to turn on for smaller loads. When the dial is turned fully clockwise, the inverter will operate even when there is no
load. Turn the dial counterclockwise to increase the minimum load that will be detected, causing the inverter to stay off until the new
minimum load is reached.
Note: the factory setting for the dial is fully clockwise. However, based on the threshold load to which you’d like the inverter to respond, you should adjust the dial counterclockwise to reduce its
sensitivity until the inverter is active only when connected equipment or appliances are actually in use.
Connect Remote Control—OPTIONAL
Model features a 8-conductor telephone style receptacle on the front panel for use with an optional remote control module (Tripp Lite model
APSRM4, sold separately). The remote module allows the Inverter/Charger to be mounted in a compartment or cabinet out of sight, while
operated conveniently from within the living area or control panel of your RV. See instructions packed with the remote control module.
Connect Battery Temperature Sensing Cable—OPTIONAL
The battery temperature sensing function prolongs battery life by adjusting the charge float voltage level based on battery temperature.
Connect the sensor cable (the cable, included with select models, has an RJ style connector on one end and a black sensor on the other) to
the RJ style jack located on the side of the Inverter/Charger labeled “Remote Temp. Sense.” With user-supplied electrical or duct tape, affix
the sensor to the side of the battery below the electrolyte level. Make sure that nothing, not even tape, comes between the sensor and the
side of the battery. To guard against false readings due to ambient temperature, place the sensor between batteries, if possible, or away from
sources of extreme heat or cold. If the sensor cable is not used, the Inverter/Charger will charge according to its default 25º C values.
Utilize Automatic Generator Starter Capability—OPTIONAL
Model includes a RJ type modular jack on the side panel labeled “Generator Start”. Attach to vehicle generator
ON/OFF switching mechanism with user-supplied cable (see Pin Configuration Diagram). Once attached, the
interface will allow the Inverter/Charger to automatically switch a vehicle generator on when connected battery
voltage levels are low (11.6 VDC) and switch it off when battery voltage levels are high (14.1 VDC).
Connect Ignition Switch Control Jack—OPTIONAL
This jack (located on the Inverters side panel) can be used to connect the Inverter to your vehicle's ignition switch in order to automatically
control the Inverter. This connection is optional; the Inverter will function without this connection.
1
2
3
4
5
6
Pin Configuration
2 - Common
3 - N.C.
(Normally Closed)
4 - N.O.
(Normally Open)
Configuration
(continued)
8
Battery Selection
540 watts ÷ 12V = 45 DC Amps
270 Amp-Hours ÷ 55 Amps
Inverter/Charger Rating = 5 Hours Recharge
Select Auxiliary Battery Type (if any)
Select “Deep Cycle” batteries to receive optimum performance from your Inverter/Charger. Do not use ordinary car or starting batteries or batteries rated in
Cold Cranking Amps (CCA). If the batteries you connect to the Inverter/Charger are not true Deep Cycle batteries, their operational lifetimes may be significantly
shortened. If you are using the same battery bank to power the Inverter/Charger as well as DC loads, your battery bank will need to be appropriately
sized (larger loads will require a battery bank with a larger amp-hour capacity) or the operational lifetimes of the batteries may be significantly shortened.
Batteries of either Wet-Cell (vented) or Gel-Cell /Absorbed Glass Mat (sealed) construction are ideal. 6-volt “golf cart”, Marine Deep-Cycle or
8D Deep-Cycle batteries are also acceptable. You must set the Inverter/Charger’s Battery Type DIP Switch (see Configuration section for more
information) to match the type of batteries you connect or your batteries may be degraded or damaged over an extended period of time. In
many cases, the vehicle battery may be the only one installed. Auxiliary batteries must be identical to the vehicle batteries if they are
connected to each other.
Match Battery Amp-Hour Capacity to Your Application
Select a battery or system of batteries that will provide your Inverter/Charger with proper DC voltage and an adequate amp-hour capacity
to power your application. Even though Tripp Lite Inverter/Chargers are highly-efficient at DC-to-AC inversion, their rated output capacities
are limited by the total amp-hour capacity of connected batteries and the support of your vehicle’s alternator if the engine is kept running.
STEP 1: Determine Total Wattage Required
Add the wattage ratings of all equipment you will connect to your
Inverter/Charger. Wattage ratings are usually listed in equipment manuals or on
nameplates. If your equipment is rated in amps, multiply that number times AC
utility voltage to determine watts. (Example: a ¼ in. drill requires 2½ amps.
2½ amps × 120 volts = 300 watts .)
Note: Your Inverter/Charger will operate at higher efficiencies at about 75% - 80% of nameplate rating.
STEP 2: Determine DC Battery Amps Required
Divide the total wattage required (from step 1, above) by the battery voltage
(12) to determine the DC amps required.
STEP 3: Estimate Battery Amp-Hours Required (for operation unsupported
by the alternator)
Multiply the DC amps required (from step 2, above) by the number of hours you
estimate you will operate your equipment exclusively from battery power before
you have to recharge your batteries with utility- or generator-supplied AC power.
Compensate for inefficiency by multiplying this number by 1.2. This will give
you a rough estimate of how many amp-hours of battery power (from one or
several batteries) you should connect to your Inverter/Charger.
NOTE! Battery amp-hour ratings are usually given for a 20-hour discharge rate. Actual amp-hour capacities are less
when batteries are discharged at faster rates. For example, batteries discharged in 55 minutes provide only 50% of
their listed amp-hour ratings, while batteries discharged in 9 minutes provide as little as 30% of their amp-hour ratings.
STEP 4: Estimate Battery Recharge Required, Given Your Application
You must allow your batteries to recharge long enough to replace the charge
lost during inverter operation or else you will eventually run down your
batteries. To estimate the minimum amount of time you need to recharge your
batteries given your application, divide your required battery amp-hours (from
step 3, above) by your Inverter/Chargers rated charging amps (see the unit's
nameplate for the available charging current).
NOTE! For Tripp Lite Inverter/Chargers providing 1000 watts or less of continuous AC power, a full-size battery
will normally allow sufficient power for many applications before recharging is necessary. For mobile applications,
if a single battery is continuously fed by an alternator at high idle or faster, then recharging from utility or generator
power may not be necessary. For Tripp Lite Inverter/Chargers over 1000 watts used in mobile applications, Tripp Lite
recommends you use at least two batteries, if possible fed by a heavy-duty alternator anytime the vehicle is running.
Tripp Lite Inverter/Chargers will provide adequate power for ordinary usage within limited times without the
assistance of utility or generator power. However, when operating extremely heavy electrical loads at their peak
in the absence of utility power, you may wish to “assist your batteries” by running an auxiliary generator or vehicle
engine, and doing so at faster than normal idling.
Example
Tools
300W + 220W + 20W = 540W
¼" Drill
Orbital Sander
Cordless Tool Charger
Appliances
300W + 140W + 100W = 540W
Blender Color TV Laptop Computer
45 DC Amps × 5 Hrs. Runtime
× 1.2 Inefficiency Rating = 270 Amp-Hours
9
Mounting
WARNING! Mount your Inverter/Charger BEFORE DC battery and AC power
connection. Failure to follow these instructions may lead to personal injury
and/or damage to the Inverter/Charger and connected systems.
Tripp Lite manufactures a variety of different Inverter/Chargers with a variety of different mounting options for use in vehicular or non-vehicular
applications. Tripp Lite recommends permanent mounting of your Inverter/Charger. User must supply mounting hardware and is responsible
for determining if the hardware and mounting surface are suitable to support the weight of the Inverter/Charger. Contact Tripp Lite if you
require further assistance in mounting your Inverter/Charger.
Note: When operating a marine model in a marine application, refer to the accompanying marine owners'
manual addendum.
The Inverter must be located in an enclosed compartment, shielded from outside weather conditions.
Using the measurements from the diagram, install two user-supplied ¼" (6 mm) fasteners into a rigid horizontal surface, leaving the
heads slightly raised. Slide the Inverter/Charger forward over the fasteners to engage the mounting feet molded on the front of the
Inverter/Charger cabinet. Install and tighten additional user-supplied ¼" (6 mm) fasteners into the mounting feet molded on the rear and
sides of the Inverter/Charger cabinet. The rear feet extend beyond the unit’s cabinet to provide for adequate ventilation space behind the
cooling fan(s); they should not be removed.
The polycarbonate cabinet and mounting feet of your Inverter/Charger are durable enough to allow for wall mounting as well, if your
vehicle compartment requires this configuration. For wall mounting, the control panel of the Inverter/Charger must face to the side, not up
or down.
Allow 2" minimum front and rear clearance for adequate ventilation.
A
B
5.87 in.
(14.91 cm.)
1.64 in.
(4.15 cm.)
5.87 in.
(14.91 cm.)
5.57 in.
(14.16 cm.)
5.57 in.
(14.16 cm.)
9.59 in.
(24.35 cm.)
9.59 in.
(24.35 cm.)
A
B
M
Note: Cabinets may have different front panel features, but all mount as per the figure above.
10
• Connect DC Wiring: Though your Inverter/Charger is a high-efficiency converter of electricity, its rated output
capacity is limited by the length and gauge of the cabling running from the battery to the unit. Use the shortest
length and largest diameter cabling (maximum 2/0 gauge) to fit your Inverter/Chargers DC Input terminals.
Shorter and heavier gauge cabling reduces DC voltage drop and allows for maximum transfer of current. Your
Inverter/Charger is capable of delivering peak wattage at up to 200% of its rated continuous wattage output for
brief periods of time. Heavier gauge cabling should be used when continuously operating heavy draw equipment
under these conditions. Tighten your Inverter/Charger and battery terminals to approximately 3.5 Newton-meters
of torque to create an efficient connection and to prevent excessive heating at this connection. Insufficient
tightening of the terminals could void your warranty. Note: the unit's DC connectors may be either threaded
studs or butt splices, depending on the model.
Vehicular
Your Inverter/Charger’s Nominal DC Input Voltage must match the voltage of your battery or batteries—12 Volts in most vehicular applications.
It is possible to connect your Inverter/Charger to the main battery within your vehicle’s electrical system. In most vehicles, the Inverter/ Charger will be
connected to one or more dedicated auxiliary (house) batteries which are isolated from the drive system to prevent possible draining of the main battery.
12 Volt Inverter/Charger
12 Volts
12 Volts
3
5
12 Volt Main Battery Connection
12 Volt Alternator Vehicle Battery Ground 12 Volt Main Battery 12 Volt Auxiliary (House) Battery UL-Listed Fuse & Fuse Block (mounted
within 18 inches of the battery) Battery Isolator Large Diameter Cabling, Maximum 2/0 Gauge to Fit Terminals 8 AWG (minimum) Ground Wire
876
54321
12 Volt Inverter/Charger
12 Volts
12 Volts
12 Volts
12 Volt Main and Auxiliary (House) Battery Connection (Isolated Parallel)
1
4
1
7
6
2
5
7
3
2
Connect your Inverter/Charger to your batteries using the following procedures:
WARNING! • Failure to properly ground your Inverter/Charger to a vehicle’s chassis or earth
ground may result in a lethal electrical shock hazard.
• Never attempt to operate your Inverter/Charger without a battery or battery bank.
• Observe proper polarity with all DC connections.
DC Connectors
8
8
Battery Connection
Wire Gauge (AWG)
Watts 6 4 2 0 00 (2/0)
500 15 ft 25 ft 39 ft 62 ft 79 ft
700 11 ft 18 ft 28 ft 44 ft 56 ft
1000 8 ft 12 ft 20 ft 31 ft 39 ft
2000 4 ft 6 ft 10 ft 16 ft 20 ft
• Connect Ground: Using a #8 AWG wire or larger directly connect the Main Ground Lug to the vehicle’s chassis or earth ground. See the Feature
Identification section to locate the Main Ground Lug on your specific Inverter/Charger model. All installations must comply with national and
local codes and ordinances.
• Connect Fuse: NEC (National Electrical Code) article 551 requires that you connect all of your Inverter/Charger’s positive DC Terminals directly
to a UL-listed fuse(s) and fuse block(s) within 18 inches of the battery. The fuse's rating must equal or exceed the Minimum DC Fuse Rating shown
on your Inverter/Charger's nameplate. See diagrams below for proper fuse placement.
2
Maximum Recommended Cable Length
11
To avoid overloading your Inverter/Charger, match the power requirements of the equipment you plan to run at any one time (add their total
watts) with the output wattage capacity of your Inverter/Charger model. Do not confuse “continuous” wattage with “peak” wattage ratings.
Most electric motors require extra power at start-up (“peak wattage”) than required to run continuously after start-up, sometimes over 100%
more. Some motors, such as in refrigerators and pumps, start and stop intermittently according to demand, requiring “peak wattage” at
multiple, unpredictable times during operation. DoubleBoost
Feature: Tripp Lite Inverter/Chargers deliver up to twice their nameplate rated
wattage for up to 10 seconds,* providing the extra power needed to cold start heavy-duty tools and equipment. OverPower™ Feature: Tripp
Lite Inverter/Chargers deliver up to 150% of their nameplate-rated wattage for 1-60 minutes under ideal battery and temperature conditions*,
providing ample reserve power to support tools and equipment.
* Actual duration depends on model, battery age, battery charge level and ambient temperature. For best results, utilize OverPower for as short a duration as possible, ensure that battery bank and cabling are able to provide full
nominal DC voltage under load, and allow the inverter/charger to cool completely before and after OverPower utilization.
Warning! Consult a qualified electrician and follow all applicable electrical codes and requirements for
hardwire connection. Disconnect both DC input and AC utility supply before attempting hardwiring. Use wire
type THHN or equivalent with minimum temperature rating of 90°C.
Connection for Models with Hardwire Terminals
Output Connection Requirement: UL requires that the output terminals of all hard-
wire Inverter/Charger models must be connected to UL-listed GFCI receptacles
(required receptacle manufacturer/model series: Hubbell GF8300 or
Leviton 6598).
Single Input/Output Models
Input: Connect incoming wires to the hot (brown) , neutral (blue)
and ground* (green) terminals .
Output: Connect outgoing wires to the hot (black) , neutral (white)
and ground* (green) terminals .
Replace cover plate and tighten screws.* If the incoming conduit only contains two wires (hot and neutral), the
incoming conduit must be bonded to the main ground lug on the unit. In any case, the incoming conduit must be
bonded to earth or vehicle ground, and the incoming conduit must be bonded to the outgoing conduit.
1
2
3
4
5
AC Input/Output Connection
HOT IN
NEUTRAL IN
GROUND IN
GROUND OUT
HOT OUT
“FOR USE WITH COPPER WIRE ONLY”
NEUTRAL OUT
2
3
1
4
5
Note: Ground Bond Connection, Supplied
1
Service
Before returning your Inverter/Charger for service, follow these steps: 1.) Review the installation and operation instructions to ensure that
the service problem does not originate from a misreading of the instructions. Also, check that the circuit breaker(s) are not tripped.* 2.) If
the problem continues, do not contact or return the Inverter/Charger to the dealer. Instead, call Tripp Lite at (773) 869-1233. A service
technician will ask for the Inverter/Charger’s model number, serial number and purchase date and will attempt to correct the problem over
the phone. 3.) If the problem requires service, the technician will issue you a Returned Material Authorization (RMA) number, which is
required for service. Securely pack the Inverter/Charger to avoid damage during shipping. Do not use Styrofoam beads for packaging.**
Any damages (direct, indirect, special, incidental or consequential) to the Inverter/Charger incurred during shipment to Tripp Lite or an
authorized Tripp Lite service center is not covered under warranty. Inverter/Chargers shipped to Tripp Lite or an authorized Tripp Lite
service center must have transportation charges prepaid. Mark the RMA number on the outside of the package. If the Inverter/Charger is
within the warranty period, enclose a copy of your sales receipt. Return the Inverter/Charger for service using an insured carrier to the
address given to you by the Tripp Lite service technician.
* This is a common cause of service inquiries which can be easily remedied by following the resetting instructions in this manual. ** If you require packaging, the technician can arrange to send you proper packaging.
Your Inverter/Charger requires no maintenance and contains no user-serviceable or replaceable parts, but should be kept dry at all times.
Periodically check, clean and tighten all cable connections, as necessary, both at the unit and at the battery.
Maintenance
12
Troubleshooting
SYMPTOM PROBLEMS CORRECTIONS
No AC Output Unit is not properly connected to utility power Connect unit to utility power.
(All Indicator Lights are OFF) Operating Mode Switch is set to “DC OFF” and AC input Set Operating Mode Switch to “AUTO/REMOTE” or “CHARGE ONLY”.
is present.
This is normal when the Operating Mode Switch is set to No correction is required. AC output will return when AC input
“CHARGE ONLY” and AC input is absent. returns. Set Operating Mode Switch to “AUTO/REMOTE” if you
require AC output.
Output circuit breaker is tripped. Reset circuit breaker.
Unit has shut down due to battery overcharge (preventing Disconnect any auxiliary chargers. Reset by moving Operating Mode
battery damage). The problem may be with connected Switch to “DC OFF”. Wait 1 minute and switch to “AUTO/REMOTE”
auxiliary chargers, if any, or with the unit’s charger. or “CHARGE ONLY.” If unit remains in shutdown mode after several
attempts to reset, contact Tripp Lite Customer Service for assistance.
Unit has shut down due to excessive battery discharge. Use an auxiliary charger* to raise battery voltage. Check external
battery connections and fuse. Unit automatically resets when
condition is cleared.
Unit has shut down due to overload. Reduce load. Reset by moving Operating Mode Switch to “DC OFF”.
Wait 1 minute. Switch to “AUTO/REMOTE” or “CHARGE ONLY”.
Battery Not Recharging Connected batteries are dead. Check and replace old batteries.
(AC Input Present) Battery fuse* is blown. Check and replace fuse.*
Battery cabling* is loose. Check and tighten or replace cabling.*
Unit has shut down due to battery overcharge (preventing Disconnect any auxiliary chargers. Reset by moving Operating Mode
battery damage). The problem may be with connected Switch to “DC OFF”. Wait 1 minute and switch to “AUTO/REMOTE”
auxiliary chargers, if any, or with the unit’s charger. or “CHARGE ONLY.” If unit remains in shutdown mode after several
attempts to reset, contact Tripp Lite Customer Service for assistance.
Charger circuit breaker is tripped. Reset circuit breaker.
All Three “BATT VOLT/CHRG CURR” Battery is excessively discharged. Unit will shut down to Use an auxiliary charger* to raise battery voltage. Check external
LEDs are slowly flashing (½ second prevent battery damage. battery connections and fuse. Unit automatically resets when
flashes) with Operating Mode Switch in condition is cleared.
the “AUTO/REMOTE” position.
All Three “BATT VOLT/CHRG CURR” Battery is overcharged. Unit will shut down to prevent Disconnect any auxiliary chargers. Reset by moving Operating Mode
LEDs are rapidly flashing (¼ second battery damage. The problem may be with connected auxiliary Switch to “DC OFF”. Wait 1 minute and switch to “AUTO/REMOTE.
flashes) with Operating Mode Switch in chargers, if any, or with the unit’s charger. If unit remains in shutdown mode after several attempts to reset,
the “AUTO/REMOTE” position. contact Tripp Lite Customer Service for assistance.
Red “LOW” Battery Indicator Light is Battery voltage is low. Unit has shut down If AC power (utility- or generator-supplied) is present, the unit will
flashing with Operating Mode Switch in the to protect battery from damage. automatically reset itself and start recharging connected batteries.
”AUTO/REMOTE” position. However, if an external charger is used to recharge the batteries,
you will need to manually reset the unit by moving the Operating
Mode Switch to “DC OFF” for two seconds then returning it to
“AUTO/REMOTE”.
False reading due to undersized or Use sufficient size DC cable sufficiently connected to
insufficiently connected DC cabling. Inverter/Charger.
Red “LOAD” Operation Inverter is overloaded. Unit will automatically shut down Reduce load. Reset by moving Operating Mode Switch to “DC OFF”.
Indicator Light flashing after 5 seconds. Wait 1 minute. Switch to “AUTO/REMOTE” or “CHARGE ONLY”.
* User-supplied.
Try these remedies for common Inverter/Charger problems before calling for assistance. Call Tripp Lite Customer Service at (773) 869-1234
before returning your unit for service.
Limited Warranty
Tripp Lite warrants its Inverter/Chargers to be free from defects in materials and workmanship for a 30 month period from the date of retail purchase by end user.
Tripp Lite’s obligation under this warranty is limited to repairing or replacing (at its sole option) any such defective products. To obtain service under this warranty you must obtain a Returned Material Authorization
(RMA) number from Tripp Lite or an authorized Tripp Lite service center. Products must be returned to Tripp Lite or an authorized Tripp Lite service center with transportation charges prepaid and must be
accompanied by a brief description of the problem encountered and proof of date and place of purchase. This warranty does not apply to equipment which has been damaged by accident, negligence or
misapplication or has been altered or modified in any way, including opening of the unit’s casing for any reason. This warranty applies only to the original purchaser who must have properly registered the product
within 10 days of retail purchase.
EXCEPT AS PROVIDED HEREIN, TRIPP LITE MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Some states do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser.
EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS
PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, Tripp Lite is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of
software, loss of data, costs of substitutes, claims by third parties, or otherwise.
Regulatory Compliance Identification Numbers
For the purpose of regulatory compliance certifications and identification, your Tripp Lite product has been assigned a unique series number. The series number can be found on the product nameplate label,
along with all required approval markings and information. When requesting compliance information for this product, always refer to the series number. The series number should not be confused with the marking
name or model number of the product.
Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.
Note on Labeling Two symbols are used on the labels.
V~: AC Voltage V : DC Voltage
WARRANTY REGISTRATION
Visit www.tripplite.com/warranty to register the warranty of your new Tripp Lite product. You'll be automatically
entered into a drawing for a chance to win a FREE Tripp Lite product!*
* No purchase necessary. Void where prohibited. Some restrictions apply. See website for details.
13
Manuel du propriétaire
Alimentation mobile silencieuse
Félicitations ! Vous avez acheté le circuit inverseur/chargeur le plus avancé riche en options conçu pour les applications récréationnelles.
Le circuit inverseur/chargeur de Tripp Lite est l'alternative silencieuse aux générateurs - sans avoir affaire à la fumée, au carburant ou au
bruit. Vous obtenez une alimentation électrique c.a. en tout temps et partout où vous en avez besoin : loin de l'alimentation externe, en
roulant sur l'autoroute, en camping au fond des bois ou durant la nuit sur un site sans électricité. Votre circuit inverseur/chargeur alimente
vos électroménagers, vos équipements et appareils électroniques d'une alimentation c.a. de service - ou provenant d'une génératrice - (filtré
à travers la protection de surtension ISOBAR
®
) lorsque disponible. De plus, il alimente automatiquement votre système de véhicule 12V et
recharge votre banque de piles connectées - effectuant ce qu'un convertisseur/chargeur fait. Lors des pannes de courant ou s'il se produit
des affaissements ou des hausses de la tension, votre circuit inverseur/chargeur commute automatiquement et immédiatement pour invertir
la sortie de la pile à l'équipement c.a. connecté.
Meilleur pour votre équipement Niveaux de protection de qualité supérieure
Protection ISOBAR
®
intégrée contre les surtensions
Protection automatique de surcharge
Sortie idéale pour toutes les charges
Sortie à fréquence contrôlée
Commutation automatique de charge
Partage équilibré des charges
Meilleur pour votre batterie Recharge plus rapide de batterie
Ampérage élevé, Chargeur de batterie à 3 étages (réglable)
Protection efficace de la batterie
Conservateur de charge de batterie (Détecteur de charge)
Détection de température de batterie
Inversion hautement efficace de CC à CA
Meilleur pour vous Fonctionnement silencieux, simple et sans entretien
Lumières et commutateurs multi-fonctions
Démarrage automatique de la génératrice*
Fabrication résistant à l'humidité*
Sécurité 14
Identification des caractéristiques 15
Fonctionnement 16-17
Configuration 17-19
Choix de batterie 20
Montage 21
Connexion de la batterie 22
Connexion d'entrée/sortie CA 23
Service/Entretien 23
Dépannage 24
Garantie 14
English 1
PowerVerter
®
Chargeur/Onduleur
CC vers CA
Entrée Sortie
Inversion : 12 V CC 120V, 60 Hz. CA
Charge : 120V, 60 Hz. CA 12 V CC
1111 W. 35th Street, Chicago, IL 60609 USA
Support à la clientèle: (773) 869-1234
www.tripplite.com
* Les chargeurs-onduleurs résistent à
Copyright © 2007. Tous droits réservés. Pow
Table des matières
14
Importantes directives de sécurité
CONSERVEZ CES DIRECTIVES!
Ce manuel contient d'importantes directives et mises en garde que vous devez suivre pendant l'installation, le fonctionnement et l'entreposage
de tous les chargeurs-onduluers de Tripp-Lite.
Mises en garde concernant l'emplacement
Même si votre chargeur-onduleur résiste à l'humidité, il N'est PAS étanche.. Noyer l'unité entraînerait un court-circuit et pourrait
causer des blessures par choc électrique. Ne jamais immerger l'unité et éviter toute zone où de l'eau pourrait s'accumuler. Il faut la
fixer dans la zone la plus sèche possible.
Laisser un dégagement d'au moins 51mm (2 po) à l'avant et à l'arrière du chargeur-onduleur pour une bonne aération. Pour éviter la
fermeture automatique du chargeur-onduleur à cause d'une surchauffe, tout compartiment contenant le chargeur-onduleur doit être
correctement aéré avec une ventilation adéquate d'air extérieur. Plus la charge de l'équipement connecté est importante, plus l'unité
génère de chaleur.
Ne pas monter l'unité avec son panneau avant ou arrière à l'envers (quelque soit l'angle). Monter de cette façon va entraver
sérieusement le refroidissement interne de l'unité, endommageant le produit non couvert sous garantie.
Ne pas installer le chargeur-onduleur près d'un dispositif de stockage magnétique, cela pourrait entraîner de la corruption de données.
Ne pas installer près de matières inflammables, combustible ou produits chimiques.
Mises en garde concernant la connexion de la batterie
Le chargeur-onduleur ne fonctionnera pas (avec ou sans alimentation) avant que les batteries soient connectées.
Les systèmes à batteries multiples doivent consister en batteries de tension, d'âge, de capacité ampère/heure et de type identiques.
Parce que l'hydrogène explosif peut s'accumuler près des batteries si elles ne sont pas bien aérées, vos batteries ne doivent pas être
installées (que ce soit pour une application mobile ou stationnaire) dans un compartiment sans circulation d'air. Idéalement, un
compartiment devrait avoir un ventilation d'air extérieur.
La connexion finale de la batterie peut causer des étincelles. Toujours observer la bonne polarité en connectant les batteries.
Ne pas laisser des objets faire contact entre les deux bornes d'entrée CC. Ne pas relier ces bornes ensemble. Il pourrait en résulter des
blessures et des dommages à la propriété.
Mises en garde concernant la connexion de l'équipement
Ne pas utiliser un chargeur-onduleur Tripp Lite dans les applications de survie ou de soins de santé où un mauvais
fonctionnement ou une panne du chargeur-onduleur Tripp Lite pourraient entraîner une panne du dispositif de survie ou
de l'équipement médical ou altérer sa performance de façon importante.
Vous pourriez expérimenter des résultats de performance inégaux si vous branchez un éliminateur de surtension, un filtre de secteur ou
système UPS à la sortie de votre chargeur-onduleur.
Tripp Lite recommande de câbler la sortie CA à un disjoncteur de fuite à la terre.
La cosse principale de mise à la terre doit être connectée au châssis du véhicule avec un fil de calibre 8 AWG (minimum).
Mises en garde de fonctionnement
Votre chargeur-onduleur ne nécessite pas d'entretien de routine. N'ouvrir l'appareil sous aucune raison. Aucune pièce interne n'est
réparable par l'utilisateur.
Des tensions mortelles existent potentiellement dans le chargeur-onduleur aussi longtemps que le bloc d'alimentation par batterie ou l'entrée
CA est connecté. Il faut donc déconnecter l'alimentation par batterie ou la connexion d'entrée CA (s'il y en une) pendant tout travail d'entretien.
Ne pas connecter ou déconnecter les batteries pendant que le chargeur-onduleur fonctionne soit en mode onduleur soit en mode de
charge. Le commutateur du mode de fonctionnement doit être en position OFF (fermé). Il pourrait se former des arcs électriques.
Attention : Certains modèles disposent d'un dispositif de passage à sécurité intrinsèque CA dans lequel la sortie CA sera
vivante (si l'entrée CA est disponible) même si l'interrupteur de mode de fonctionnement est placé sur DC OFF (Arrêt CC).
Attention: Si votre Inverseur/Chargeur est installé dans un endroit mal ventilé, la surface du boitier en métal peut
s'échauffer. Laisser refroidir avant manipulation. Si l' Inverseur/Chargeur doit être installé dans un endroit mal
ventilé, installer l'unité de manière à ce que le haut du boitier en métal ne soit pas sujet à un contact accidentel
pendant l'opération.
15
Identification des caractéristiques
Identifier les caractéristiques de qualité supérieure sur votre modèle particulier et trouver rapidement les directives sur la manière de
maximiser leur utilisation.
Commutateurs de configuration à boîtier DIP : Optimise le
fonctionnement du chargeur-onduleur selon votre application.
Voir la section configuration pour les directives de réglage.
Commutateur Mode de fonctionnement : Commande le
fonctionnement du chargeur-onduleur. Le réglage « AUTO/
REMOTE » assure que votre équipement reçoit une
alimentation constante et ininterrompue de courant continu. Il
permet aussi de surveiller et de commander le chargeur-
onduleur à distance à l'aide d'un module optionnel de
commande à distance (modèle Tripp Lite APSRM4, vendu
séparément) Avec le réglage " CHARGE ONLY ", vos batteries
reviennent en pleine charge plus rapidement en fermant le
convertisseur ce qui arrête le déchargement des batteries. Voir la
section Fonctionnement pour les directives de réglage.
*
DEL « LINE », « INVERT », « LOAD » : Les voyants intuitifs
« feux de circulation » signalent si le chargeur-onduleur
fonctionne à partir d'une ligne CA ou d'une batterie CC. Ils vous
avertissent également quand la charge de votre équipement est
trop élevée. Voir la section Fonctionnement pour les directives
sur la lecture des lampes témoin.
DEL de TENSION DE BATTERIE ( « BATT VOLTAGE » ) :
Ces trois indicateurs s'allumeront en plusieurs séquences pour
indiquer le niveau approximatif de la batterie.
Bornes d'alimentation CC : Connectez à vos bornes de
batteries. Voir la section Connexion de batterie pour les
directives.
Bornes Entrée/Sortie CA à raccordement fixe : connecte
sécuritairement le chargeur-onduleur à un véhicule ou à l'entrée
du système électrique de l'installation et sortie recommandée,
protégée par un disjoncteur de fuite à la terre. Voir la section
Connexion Entrée/Sortie CA pour les directives.
Disjoncteurs réarmable : protège votre chargeur-onduleur
contre les dommages dus à surcharger ou une panne de
chargeur. Voir la section Fonctionnement pour les directives de
réenclenchement.
Connecteurde module de commande à distance : permet la
surveillance et le commande à l'aide d'un module optionnel
(modèle Tripp Lite APSRM4, vendu séparément). Voir le
manuel du propriétaire de module distant pour des directives de
connexion.
Commande (détecteur de charge) du conservateur de charge
de batterie : conserve la puissance de la batterie en réglant le
niveau de la charge minimale auquel l'onduleur du chargeur-
onduleur s'éteint automatiquement. Voir la section
Configuration pour les directives de réglage.
Cosse principale de mise à la terre : met correctement à la
terre le chargeur-onduleur au système de mise à la masse d'un
véhicule ou à la terre. Voir la section Configuration pour les
directives.
Ventilateur de refroidissement à plusieurs vitesses : un
ventilateur silencieux et efficace prolonge la vie de
l'équipement.
Couvercle d'Entrée/Sortie CA à raccordement fixe
Connecteur de detection de température de batterie :
prolonge la vie de la batterie en ajustant la charge en fonction de
la température de la batterie. Utilisé avec un câble (compris sur
les modèles Select) Voir la section Configuration pour les
détails.
Connecteur de démarrage automatique de génératrice :
manœuvre automatiquement la génératrice selon la tension de la
batterie. Usage avec un câble fourni par l'utilisateur. Voir la
section Configuration pour les détails.
Jack de Contrôle du Commutateur d'Allumage : à utiliser
pour connecter l'Inverseur au commutateur d'allumage de votre
véhicle (à l'aide du cable fourni par l'utilisateur) pour contrôler
automatiquement l'Inverseur au commutateur d'allumage de
votre véhicle. Voir section Opérations.
1
2
3
4
5
6
7
8
9
Vue avant
Vue arrière
Montage latéral,
non montré
Montage latéral,
non montré
10
11
12
13
14
* OFF (Arrêt) - Arrête l'alimentation de l'unité et de la sortie CA sur la plupart des modèles.
DC OFF (Arrêt CC) - Arrête l'alimentation de l'unité et connecte la sortie CA à l'entrée CA sur les modèles choisis.
15
Montage latéral,
non montré
HOT IN
NEUTRAL IN
GROUND IN
GROUND OUT
HOT OUT
“FOR USE WITH COPPER WIRE ONLY”
NEUTRAL OUT
1
24 3
5
7
6
10
11
8
9
13
14
12
15
16
Fonctionnement
Modes de commutation
Après avoir configuré, monté et connecté votre chargeur-onduleur, vous
êtes capable de le faire fonctionner en commutant entre les différents
modes de fonctionnement suivants corespondants à votre situation :
AUTO/REMOTE (automatique/à distance) :
Commuter vers ce mode lorsque vous avez besoin
d'une alimentation CA constante et ininterrompue
pour les appareils et l'équipement connectés. Le
chargeur-onduleur fournira continuellement
l'alimentation CA à l'équipement connecté et chargera
vos batteries connectées tant qu'il y aura une alimentation CA de
secteur ou fournie par une génératrice. Comme le convertisseur est
(en marche) ON (mais en attente) dans ce mode, il commutera
automatiquement vers votre système de batterie pour alimenter en
CA l'équipement connecté en l'absence d'une source
secteur/génératrice ou dans des situations de sous ou de surtension.
« AUTO/REMOTE » permet aussi à un module optionnel de
commande à distance (modèle Tripp Lite APSRM4, vendu
séparément) de fonctionner lorqu'il est connecté à l'unité.
CHARGE ONLY (charge seulement) : Commuter
vers ce mode lorsque vous n'utilisez pas les appareils
et l'équipement connectés pour conserver la
puissance de la batterie en désactivant l'onduleur. Le
chargeur-onduleur fournira continuellement
l'alimentation CA à l'équipement connecté et
chargera vos batteries connectées tant qu'il y aura une alimentation
CA de secteur ou fournie par une génératrice. Cependant, comme le
convertisseur est (à l'arrêt) OFF dans ce mode, il N'alimentera PAS
en CA l'équipement connecté en l'absence d'une source
secteur/génératrice ou dans des situations de sous ou de surtension.
OFF (arrêt, la plupart des modèles) : Commuter
vers ce mode pour fermer complètement le chargeur-
onduleur, empêchant l'onduleur de tirer du courant
des batteries et empêchant aussi que le courant du
secteur se rende à l'équipement connecté ou de
charger les batteries. Utiliser ce commutateur pour
réactiver automatiquement l'unité si elle s'est arrêtée à cause d'une
surcharge ou d'une surchauffe. Enlever d'abord la charge
excédentaire ou laisser l'unité se refroidir suffisament (selon votre
situation). Commuter sur « OFF », puis revenez à «
AUTO/REMOTE » ou « CHARGE ONLY » comme désiré. si
l'unité ne se réactive pas, enlever plus de charge ou laissez-la se
refroidir plus longtemps et recommencer. Utilisez un module
optionnel de commande à distance (modèle Tripp Lite APSRM4,
vendu séparément) pour réactiver l'unité en cas de surcharge ou de
surchauffe.
DC OFF [Arrêt CC] (Modèles choisis) - Arrête l'alimentation de
l'unité et connecte la sortie CA à l'entrée CA.
Voyants indicateurs
Votre chargeur-onduleur (ainsi qu'un module optionnel de commande
à distance Tripp Lite vendu séparément) est équipé d'un ensemble de
voyants indicateurs simple, intuitif et convivial. Ces voyants « feux de
circulation » faciles à se remémorer vous permettront, peu après un
premier usage, de savoir d'un coup d'œil de nombreux détails de
fonctionnement.
« DEL vert de LIGNE » : Si le commutateur de
mode fonctionnement est sur « AUTO/REMOTE »
cette lumière sera ALLUMÉE
CONTINUELLEMENT quand votre équipement
connecté recevra une alimentation continue CA de
secteur ou fournie par une génératrice.
Si le commutateur de mode fonctionnement est sur « CHARGE
ONLY » cette lumière CLIGNOTERA pour vous avertir que le
convertisseur de l'unité est à OFF (arrêt) et N'alimentera PAS en CA
l'équipement en l'absence d'une source de secteur/génératrice ou
dans des situations de sous ou de surtension.
DEL jaune « INV » (inversion) Cette lumière sera
ALLUMÉE CONTINUELLEMENT chaque fois que
l'équipement connecté reçoit un alimentation CA
inversé des batteries (en l'absence d'une source
secteur/génératrice ou dans des situations de sous ou
de surtension). Cette lumière sera éteinte quand la
charge est alimentée en CA. Cette lumière CLIGNOTERA pour
vous avertir que la charge est inférieure au réglage de conservation
(détection de charge) de la charge de batterie.
DEL rouge « LOAD » : Cette lumière rouge sera
ALLUMÉE CONTINUELLEMENT chaque fois que
l'onduleur fonctionne et que la puissance demandée
par les appareils et l'équipement connectés excède les
100% de la capacité de charge. Cette lumière
CLIGNOTERA pour vous avertir que l'onduleur s'est
arrêté à cause d'une sévère surcharge ou surchauffe. Si cela arrive,
tourner le commutateur de fonctionnement sur « OFF »; enlever la
surcharge et laisser l'unité refroidir. Vous pourrez ensuite tourner le
commutateur de fonctionnement sur « AUTO/REMOTE » ou
« CHARGE ONLY » après que l'unité a suffisament refroidi. Cette
lumière sera éteinte quand la charge est alimentée en CA.
DEL de TENSION DE BATTERIE ( « BATT VOLTAGE » ) : Si
le commutateur de mode de fonctionnement est à
« AUTO/REMOTE » (Automatique/à distance) ou à la position
« Charge Only » (charger seulement), les DEL indiquent le niveau
approximatif de charge et la tension de votre groupe de batteries
connecté et vous signale plusieurs conditions de défaut. Voir le
tableau pour les niveaux de charge et de tension.
Fonction DEL
avec le commutateur sur «AUTO/REMOTE» or
«CHARGE ONLY»
Niveau de charge approximatif de la batterie*
Capacité de
DEL la batterie :
allumées (Charge/décharge)
Verte 91%–Pleine
Verte et jaune 81%–90%
Jaune 61%–80%
Jaune et rouge 41%–60%
Rouge 21%–40%
Les trois lumières éteintes 1%–20%
Rouge clignotant 0% (Onduleur
à l'arrêt)**
* Les niveaux de charge sont approximatifs. Les conditions réelles varient selon l'état et la
charge de la batterie. ** L'arrêt de l'onduleur protège la batterie contre les dommages dus à
une décharge excessive.
État de défaut
DEL État de
allumées défaut
Les trois lumières Décharge excessive
clignotent lentement* (Onduleur arrêté)
Les trois lumières Surcharge
clignotent rapidement** (chargeur arrêté)
*Approximativement 1/2 seconde allumées, 1/2 seconde éteintes. Voir section Dépannage.
L'arrêt de l'onduleur protège la batterie contre les dommages dus à une décharge excessive.
** Approximativement 1/4 seconde allumées, 1/4 seconde éteintes. L'arrêt du chargeur protège
la batterie contre les dommages dus à une surcharge. Peut aussi indiquer un défaut de chargeur
de batterie. Voir section Dépannage.
DC
OFF
CHARGE
ONLY
AUTO/
REMOTE
DC
OFF
CHARGE
ONLY
AUTO/
REMOTE
DC
OFF
CHARGE
ONLY
AUTO/
REMOTE
1
2
3
4
5
6
7
1
2
1
2 3
4
5
6
7
1
2
17
Choisir le type de batterie -REQUIS
ATTENTION : Le réglage du commutateur DIP de type de
batterie doit correspondre aux types de batteries que vous
connectez, ou vos batteries pourraient se dégrader ou être
endommagées sur une longue période. Voir " Choix de la
batterie ", p.20 pour plus de renseignements.
Type de batterie Position du commutateur
Batterie à cellule en gel (scellée) Haut
Batterie à cellule liquide (ventilée) Bas (réglage d'usine)
Configuration
Régler les commutateurs DIP de configuration
À l'aide d'un petit outil, régler les commutateurs DIP de configuration (situés sur la panneau avant, voir schéma) pour optimiser le
fonctionnement du chargeur-onduleur selon votre application.
A1A2A3A4
cellule en gel
cellule li
q
uide
OUTPUT C/B 12A
B4 B3 B2 B1
A4 A3 A2 A1
Commutateurs DIP du Groupe B
Commutateurs DIP du Groupe A
Commutateurs DIP du Groupe A
À l'aide d'un petit outil, configurer votre chargeur-onduleur en réglant les commutateurs DIP du groupe A situés sur la panneau avant, voir
schéma) comme suit :
A1
Fonctionnement
(suite)
Position pour réarmer votre chargeur-onduleur pour restaurer l'alimentation CA
Votre chargeur-onduleur peut cesser de fournir une alimentation CA ou une alimentation de charge CC de façon à se protéger contre une
surcharge ou pour protéger votre système électrique. Pour restaurer un fonctionnement normal :
Réarmement de surcharge : Placer le commutateur de mode de fonctionnement sur « OFF » ( ou « DC OFF » ) et enlever une partie de
la charge électrique connectée (c.-à-d. fermer certains des appareils CA qui peuvent avoir causé la surcharge de l'unité). Attendreune minute,
puis remettre le commutateur de fonctionnement sur « AUTO/REMOTE » ou « CHARGE ONLY ».
Le chargeur interdit
Fonction Position du commutateur
Le chargeur a interdit Haut
Le chargeur a rendu capable Bas (réglage d'usine)
A2
A1A2A3A4
Choix du point de tension
supérieur d'entrée CA pour
passer sur batterie—
OPTIONNEL*
Position du
Tension commutateur
105V No A4 en haut & No A3 en haut
95V No A4 en haut & No A3 en bas
85V No A4 en bas & No A3 en haut
75V No A4 en bas & No A3 en bas
(réglage d'usine)
A1A2A3A4
A1A2A3A4
A1A2A3A4
A1A2A3A4
A3
A4
* La plupart de vos appareils et de l'équipement connectés fonctionnera adéquatement quand le point de tension supérieur d'entrée
CA de votre chargeur-onduleur (commutateur DIP 2 du Groupe A) est réglé à 135 V et que son point de tension inférieur d'entrée
CA (commutateur DIP 3 et 4 du Groupe A ) est réglé à 95 V. Cependant, si l'unité passe fréquemment sur batterie à cause de
variations temporaires de tension basse et elevée qui n'auraient que peu d'effet sur le fonctionnement de l'équipement, vous pourriez
vouloir ajuster ces réglages. En augmentant le point de tension supérieur d'entrée CA ou en abaissant le point de tension inférieur
d'entrée CA, vous réduirez le nombre de fois où votre unité passe sur batterie à cause de variations de voltage.
18
Choix des points de limitation du chargeur de batterie-
OPTIONNEL
« Limitation majeure » (B2 & B1 en
haut) : La limitation du chargeur prend
effet au moment où une charge de 120 V
CA est appliquée; la sortie du chargeur
passe graduellement de « sortie pleine sans
charge de 120 V » à « pas de sortie à pleine charge ».
« Limitation mineure » ( B2 en haut &
B1 en bas ) : La limitation du chargeur
commence losrque la charge du chargeur-
onduleur atteint 33 % du régime nominal
du chargeur-onduleur. La sortie du
chargeur passe graduellement de la sortie pleine à 33% du régime
nominal du chargeur-onduleur à environ 40% de la sortie pleine à
pleine charge.
Configuration
(suite)
B1B2B3B4
B1B2B3B4
Commutateurs DIP du Groupe B
Choix du partage de CA—OPTIONNEL
Votre chargeur-onduleur possède un chargeur de batterie à sortie élevée qui peut consommer une quantité importante de puissance CA du
secteur ou de la génératrice quand il charge à son régime maximal. Si la lourde charge électrique connectée est alimentée en CA à plein
régime par votre unité et qu'en même temps cette charge élevée survient, le disjoncteur d'entrée CA peut sauter entraînant l'arrêt complet
de l'alimentation du secteur.
Pour réduire la possibilité de déclenchement de ce disjoncteur, tous les chargeurs-onduleurs peuvent être réglés pour limiter
automatiquement la sortie du chargeur. La somme de la charge CA de l'unité et de l'alimentation de charge reste inférieure à la charge
nominale du disjoncteur. Si nécessaire, la fonction de limitation du chargeur possède quatre réglages vous permettant de réduire la
consommation du charge de plus en plus si le disjoncteur d'entrée CA continue de se déclencher sous des charges CA normales d'appareils
branchés en aval de l'unité. Les figures montrent comment régler vos commutateurs DIP pour la limitation du chargeur.
B1
B2
Réglage de l'intensité de charge de batterie—OPTIONNEL
Vérifier les spécifications des options d'intensité de charge supérieure et
inférieure de votre unité. En réglant la charge supérieure, vos batteries
chargeront à la vitesse maximale et les
charges de votre système RV 12V DC seront
bien alimentées. En réglant la charge
inférieure, vous rallongez la durée de vos
batteries.
Chargeur de batterie Position du commutateur
Intensité inférieure de charge Haut
Intensité supérieure de charge Bas (réglage d'usine)
ATTENTION : En passant sur l'intensité supérieure de charge, l'utilisateur doit s'assurer que
la capacité ampères/heure du système de batterie excède l'ampérage du réglage d'intensité
supérieure de charge ou les batteries pourraient s'endommager ou se dégrader.
Choix de l'égalisation de la charge de la batterie—
OPTIONNEL
Ce commutateur DIP est engagé
momentanément pour commencer le
processus d'égalisation de l'état de charge
des cellules de votre batterie par une
surcharge temporaire de toutes les cellules.
Cela permet de prolonger la vie de certains types de batteries;
consulter votre fabricant de batterie pour savoir si vos batteries
peuvent bénéficier de ce processus. Le processus d'égalisation de la
charge est automatique; un fois commencé, il peut seulement être
arrêté en enlevant l'alimentation d'entrée.
Procédure de réglage
Aller à la position « Égaliser » (EN BAS) pendant trois secondes.
Aller à la position « Réamorcer » (EN HAUT) et restez là. C'est
un réglage d'usine par défaut.
ATTENTION : Ne pas laisser le commutateur DIP B3 dans la position basse après le début du
processus. L'égalisation de la charge de la batterie doit être effectuée en stricte concordance
avec les directives et les spécifications du fabricant de batterie.
Charge de la batterie Position du commutateur
Réamorcer En haut (réglage d'usine)
Égaliser En bas—momentanément
B1B2B3B4
Intensité inférieure
de charge
Intensité supérieure
de charge
Réamorcer
Égaliser
B1B2B3B4
B4
B3
(réglage d'usine)
19
Régler la commande de conservation de charge de batterie (Détecteur de charge)—OPTIONNEL
Dans le but de sauvegarder la puissance de la batterie, l'onduleur de l'unité s'arrête automatiquement en l'absence de demande
d'alimentation d'un équipement ou d'appareils connectés (la charge électrique). Quand l'unité détecte une charge, il met en
marche automatiquement la fonction de l'onduleur. L'utilisateur peut choisir la charge minimale que le chargeur-onduleur
détectera en réglant la commande de conservation de charge de batterie (voir schéma). À l'aide d'un petit outil, tourner la
commande dans le sens horaire pour abaisser la charge minimale qui sera détectée, entraînant la mise en marche l'onduleur pour
de plus petites charges. Quand la rotation du cadran dans le sens horaire est complète, l'onduleur fonctionnera même sans charge. Tourner le
cadran dans le sens antihoraire pour augmenter la charge minimale qui sera détecté, entraînant la mise à l'arrêt l'onduleur jusqu'à ce que la
nouvelle charge minimale soit atteinte.
Remarque : Le réglage en usine est la rotation complète du cadran dans le sens horaire. Cependant, en fonction du seuil de charge auquel vous voudriez que l'onduleur réponde, vous devez régler le
cadran dans le sens antihoraire pour réduire sa sensibilité jusqu'à ce que l'onduleur soit actif seulement quand l'équipement et les appareils connectés sont réellement en usage.
Connexion de la commande à distance—OPTIONNEL
Tous les modèles sont équipés d'une prise sytle téléphone à 8 conducteurs pour utilisation à l'aide d'un module module optionnel de
commande à distance (modèle Tripp Lite APSRM4, vendu séparément). Le module à distance permet au chargeur-onduleur d'être monté
dans un compartiment ou une armoire hors de vue, tout en fonctionnant commodément depuis une zone d'activité ou à partir du panneau
de contrôle de votre VR. Voir les directives jointes au module de commande à distance
Connexion de câble de detection de température de batterie
La fonction de détection de température de batterie prolonge la durée de la batterie en réglant le niveau de tension flottante de charge en
fonction de la température de la batterie. Connecter le câble du capteur (le câble, y compris sur les modèles Select, a un connecteur de style RJ
à une extrémité et un capteur noir à l'autre) au jack de style RJ situé sur le côté* du chargeur-onduleur et identifié « Remote Temp. Sense »
(Détection de température à distance). À l'aide de ruban adhésif électrique ou en toile fourni par l'utilisateur, fixer le capteur sur le côté de la
batterie sous le niveau de l'électrolyte. Assurez-vous qu'il n'y a rien, même pas du ruban, entre le capteur et le côté de la batterie. Pour empêcher
de fausses lectures dues à la tempéérature ambiante, placer le capteur entre les batteries, si possible, ou loin de sources extrêmes de chaleur ou
de froid. Si le câble du capteur n'est pas utilisé, le chargeur-onduleur chargera selon sa valeur par défaut de 25°C.
Utilisation de la capacité de démarrage automatique de l'alternateur
Tous les modèles à l'exception des modèles 750 sont équipé d'un jack modulaire de Type RJ sur la panneau
latéral identifié « Démarrage de la génératrice ». Connecter le mécanisme de commutation ON/OFF (arrêt
/marche) de l'alternateur du véhicule à un câble fourni par l'utilisateur (voir la configuration de la broche). Une
fois connectée, l'interface permettra au chargeur-onduleur de commuter automatiquement sur l'alternateur d'un
véhicule quand les niveaux de tension de la batterie connectée sont bas (11,6 V CC) et de se débrancher quand les niveaux de batterie sont
élevés (14,1 V CC).
Connecter Jack de Contrôle du Commutateur d'Allumage—OPTIONNEL
Ce jack (situé sur le panneau latéral de l'Inverseur) peut être utilisé pour connecter l'Inverseur au commutateur de l'allumage de votre
véhicule pour contrôler automatiquement l'Inverseur. Cette connexion est facultative; l'Inverseur fonctionnera sans cette connexion.
1
2
3
4
5
6
Configuration
de la broche
2 - Commun
3 - N.C.
(Normallement fermée)
4 - N.O.
(Normallement ouverte)
Configuration
(suite)
20
Choix de batterie
540 watts ÷ 12V = 45 A CC
270 A/h ÷ 55 A
Régime du chargeur-onduleur =
5 heures de recharge
Choix du type de batterie auxiliaire (s'il y en a)
Choisir des batteries « à décharge poussée » pour obtenir une performance maximale de votre chargeur-onduleur, Ne pas utiliser de batterie ordinaire de
voiture ou de démarrage ou de batteries notées à intensité de démarrage à froid (Cold Cranking Amps CCA). Si les batteries connectées au chargeur-onduleur
ne sont pas de vraies batteries à décharge poussée, leur durée de fonctionnement pourrait être considérablement réduite. Si vous utilisez le même groupe de
batteries pour alimenter le chargeur-onduleur ainsi que les charges CC, votre groupe de batteries devra être calibré adéquatement (des charges plus lourdes
exigeront un groupe de batteries avec un plus grande capacité A/h) ou la durée de fonctionnement des batteries pourrait être considérablement réduite.
Les batteries à celulles liquides (ventilées) ou à cellules en gel/ AGM (scellées) sont idéales. Les batteries 6 volts de voiturette de golf, marine à décharge
poussée ou à décharge poussée 8D sont aussi acceptables. Vous devez régler le commutateur DIP de type de batterie du chargeur-onduleur (voir la section
Configuration pour plus de renseignements) pour l'apparier aux types de batteries que vous connectez ou vos batteries pourraient se dégrader ou être
endommagées sur une longue période. Dans beaucoup de cas, la batterie du véhicule sera la seule installée. Les batteries auxiliaires doivent être identiques
aux batteries du véhicule si elles sont connectées ensemble.
Correspondance de la capacité A/h de la batterie à votre application
Choisir une batterie ou un système de batteries qui fournira à votre chargeur-onduleur un voltage CC approprié et une capacité A/h
suffisante pour alimenter votre application. Même si les chargeurs-onduleurs sont hautement efficaces pour la conversion du CC au CA,
leur capacité nominale de sortie est limitée par la capacité totale en A/h des batteries connectées et le support de l'alternateur de votre
véhicule si le moteur est en marche.
ÉTAPE 1: Détermination du wattage total requis
Additionnez les puissances nominales de tout l'équipement connecté à votre
chargeur-onduleur. Les puissances nominales sont généralement indiquées dans les
manuels d'équipement ou sur les plaques signalétiques. Si votre équipement est
indiqué en ampères, multiplier le nombre d'ampères par 120 pour calculer la
puissance. (Exemple : Une perceuse 1/4 po a besoin de 2,5 A. 2,5 A o 120 volts =
300 watts .)
Remarque : Votrechargeur-onduleur sera plus efficace entre 75 % et 80 % de la puissance indiquée sur
la plaque signalétique.
ÉTAPE 2: Détermination de l'intensité de la batterie requise en CC
Divisez le wattage total requis (d'après l'étape 1, ci-dessus) par le voltage de la
batterie (12) pour déterminer l'intensité CC requise.
ÉTAPE 3: Estimation des A/h de batterie requis (pour un fonctionnement
non supporté par l'alternateur)
Multipliez l'intensité requise (d'après l'étape 2, ci-dessus) par le nombre estimé
d'heures du fonctionnement de votre équipement alimenté exclusivement par
batterie avant que vous ne deviez recharger vos batteries en CA sur le secteur ou
avec une génératrice. Compensez pour l'inefficacité en multipliant ce chiffre par 1,2.
Cela vous donnera une estimation grossière de la puissance de batterie en A/h (d'une
ou de plusieurs batteries) que vous devrez connecter à votre chargeur-onduleur.
REMARQUE! : La puissance nominale en A/h des batteries est habituellement donnée pour un régime de décharge
de 20 h. Les capacités réelles en A/h sont moindres quand les batteries se déchargent à un régime plus rapide. Par
exemple, des déchargées en 55 minutes fournissent seulement 50 % de leur puissance nominale en A/h, tandis que
les batteries déchargées en 9 minutes ne fournissent que 30 % de leur puissance nominale en A/h.
ÉTAPE 4 : Estimation de la recharge de batterie requise, selon votre
application
Vous devez laisser vos batteries se recharger assez longtemps pour remplacer
la charge perdue pendant le fonctionnement de l'onduleur ou vous épuiserez
éventuellement vos batteries. Pour estimer la durée minimale de recharge de
vos batteries, selon votre application, diviser la capacité requise en A/h de votre
batterie (d'après l'étape 3, ci-dessus) par l'ampérage nominal de charge de votre
chargeur-onduleur (voir la feuille de spécifications à part).
REMARQUE! : Pour les chargeurs-onduleurs de Tripp Lite fournissant 1 000 watts ou moins d'alimentation CA
continue, une batterie à grande capacité sera normallement suffisamment puissante pour alimenter plusieurs
applications avant qu'une recharge soit nécessaire. Pour les applications mobiles, si une seule batterie est
continuellement rechargée par un alternateur à ralenti élevé ou plus rapide, alors il ne sera peut-être pas
nécessaire de la recharger depuis le secteur ou d'une génératrice. Pour les chargeurs-onduleurs de Tripp Lite de
plus de 1 000 watts utilisés dans les applications mobiles, Tripp Lite recommande que vous utilisiez au moins
deux batteries, rechargées si possible par un alternateur robuste chaque fois que le véhicule est en marche. Les
chargeurs-onduleurs de Tripp Lite vous fourniront une alimentation adéquate pour un usage ordinaire dans des
durées limitées sans le support d'une alimentation de secteur ou de génératrice. Cependant, lors du
fonctionnement de charges électriques extrêmement lourdes à leur puissance maximale, vous pourriez avoir
envie « d'assister vos batteries » en faisant tourner une génératrice auxiliaire ou un moteur de véhicule et le faire
à une vitesse plus rapide que le ralenti.
Exemple
Outils
300W + 220W + 20W = 540W
Perceuse 1/4 po
Ponceuse orbitale
Chargeur d'outil sans fil
Appareils
300W + 140W + 100W = 540W
Mélangeur TV couleur Ordinateur portable
45 A CC o 5 h. (durée)
1,2 (taux d'inefficacité) = 270 A/h
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Tripp Lite DC-to-AC Inverter Le manuel du propriétaire

Catégorie
Adaptateurs secteur
Taper
Le manuel du propriétaire

dans d''autres langues