MAINTENANCE
Disconnect power and release all pressure from
the system before attempting to install, service, relocate or perform any
maintenance. Lock the power disconnect in the open (OFF) position. Tag
out the power disconnect to prevent unexpected application of power.
Débrancher de la source d’alimentation puis
dissiper toute la pression du système avant d’essayer d’installer,
de réparer, de déplacer ou de procéder à l’entretien. Verrouiller
le sectionneur de courant en position ouverte (OFF). Étiqueter le
sectionneur de courant pour éviter toute mise sous tension imprévue.
Protect the pump from freezing during winter
conditions.
MISE EN GARDE
Protéger la pompe du gel pendant l’hiver.
DRAINING THE PUMP
Drain openings are provided on all models.
To drain the pump:
1. Remove drain fitting and prime plug to vent the system.
2. Drain all piping to a point below the freeze line.
DRAINING THE TANK
Conventional tanks can be drained by opening an outlet at the
lowest point in the system. Remove plug or the air volume control
to vent the tank.
Precharged tanks force virtually all the water from the tank when
system pressure is released. No draining is necessary.
RESTARTING PUMP
If the pump has been serviced, drained or has not been used for
some time, be sure there is water in the pump housing (volute) and
the piping to the well. There must be water in the pump housing
(volute) at all times when the pump is running to avoid internal
damage of seal members.
WATERLOGGED TANKS: CONVENTIONAL
When a tank system has an inadequate ratio of air and water, the
pump will start and stop often and eradically.
1. Disconnect the power to the pump.
2. Open the lowest faucet in the system to release all pressurized
water in the system.
3. Prime the pump (Priming the Shallow Well Pump on page 10).
4. Reconnect the power to the pump.
NOTE: As the pump refills the tank with water, the air volume
control supplies the tank with the correct air to water ratio for the
system to operate. If the air volume control is good, the pump will
shut off at the desired cut-off and will be adjusted correctly.
WATERLOGGED TANKS: PRECHARGED
If a precharged tank becomes waterlogged, the bladder is normally
leaking or broken.
1. Test the tank by depressing the air valve. The air valve will expel
water if the bladder is broken.
2. If broken, replace the tank.
NOTE: Once a bladder is leaking or broken, the bladder cannot be
repaired. The tank must be replaced.
LUBRICATION
The bearings used in the pumps are lifetime lubricated at the factory
and require no additional lubrication.
PRECHARGED TANK
Some air is lost through the bladder in any tank. To prevent tank
failure, check the tank precharge on a yearly basis.
1. Disconnect power to the pump, so water does not refill the
precharged tank.
2. Open a faucet nearest to the tank and allow all water to drain
from the tank, then close.
3. Measure the tank precharge at the valve stem using a tire
gauge.
4. If necessary, adjust the precharge with an air pump 28 - 30 psi
on the pump.
5. Reconnect power to the pump.
LIMITED WARRANTY
For three years for CWS Series models from the date of purchase, from an authorized dealer, Wayne Water Systems will repair or replace, at its option for the original
purchaser, any part or parts of its Well Pumps or Water Pumps (“Product”) found upon examination by Wayne Water Systems to be defective in materials or workmanship.
Please call Wayne Water Systems (800-237-0987) for warranty instructions. Be prepared to provide the model number and the serial number when exercising this
warranty. All transportation charges on Products or parts submitted for repair or replacement must be paid by purchaser.
This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect, improper installation, improper maintenance,
or failure to operate in accordance with Wayne Water Systems’ written instructions.
THIS WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES, OBLIGATIONS OR AGREEMENTS, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY
OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE, AND ANY RIGHTS OR REMEDIES AGAINST ANY PERSON OR ENTITY UNDER THE UNIFORM
COMMERCIAL CODE OR OTHERWISE WITH RESPECT TO THE SALE OF THE PRODUCT. THE REMEDIES AND OBLIGATIONS STATED IN THIS WARRANTY ARE THE SOLE
AND EXCLUSIVE REMEDIES OF AND OBLIGATIONS TO THE OWNER FOR ANY AND ALL MATTERS ARISING WITH RESPECT TO OR IN ANY WAY CONNECTED WITH
THE PRODUCT, REGARDLESS OF THE SOURCE OR PROVIDER OF SUCH GOODS. IN NO EVENT, WHETHER AS A RESULT OF BREACH OF CONTRACT, WARRANTY TORT
(INCLUDING NEGLIGENCE) OR OTHERWISE, SHALL WAYNE WATER SYSTEMS OR ANY AFFILIATE BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL
DAMAGES.
You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you MUST send a copy of the purchase receipt along
with the material or correspondence. Please call Wayne Water Systems (800-237-0987) for return authorization and instructions.
DO NOT MAIL THIS FORM TO Wayne Water Systems. Use this form only to maintain your records.
MODEL NO._____________________ SERIAL NO._________________________ INSTALLATION DATE __________________________
ATTACH YOUR RECEIPT HERE