Harman Stove Company ShadowLight XL Manuel utilisateur

Catégorie
Cheminées
Taper
Manuel utilisateur

Ce manuel convient également à

ShadowLight XL
Direct Vent Gas Fireplace Insert
Owners Manual
WARNING: If the information in this manual is not followed
exactly, a fire or explosion may result causing property
damage, personal injury or loss of life.
Installation and service must be performed by a qualified
installer, service agency, or the gas supplier.
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
FOR YOUR SAFETY:
WHAT TO DO IF YOU SMELL GAS
• Do not touch electrical switches.
• Do not try to light any appliance.
• Open windows.
• Extinguish any open flame.
• Do not use the phone in your building.
• Immediately call your gas supplier from a neighbor's
phone.
• Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
ADVETISSEMENT: Quinconque ne respect pas à la
lettre les instructions dans le présent manuel risque de
déclencher un incendie ou une explosion entraíant des
dommages matérials, des lésions corporelles ou la perte
de vies humaines.
L’installation et service doit être exécuté par un qualifié
installer, agence de service ou le fourmisseur de gaz.
Ne pas entreposer ni utiliser d'essence ni d'autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez une
odeur de gaz:
• Ne pas tenter d'allumer d'appareil.
Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones se trouvant dans le batiment vous
trouvez.
• Evacuez la pièce, le bâtiment ou la zone.
Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz, ap-
pelez le service dos incendies.
Tested by Intertek Testing Services/Warnock Hersey; 8431 Murphy Drive, Middleton, WI 53562
R2
8/06
Part #3-90-00395
Manufactured by:
Harman Stove Co.
352 Mountain House Road
Halifax, PA 17032
WARNING: If the information in this manual is
not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss
of life.
Installation and service must be performed by a
qualified installer, service agency, or the gas sup-
plier.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
ADVETISSEMENT: Quinconque ne respect pas
à la lettre les instructions dans le présent manuel
risque de déclencher un incendie ou une explosion
entraíant des dommages matérials, des lésions
corporelles ou la perte de vies humaines.
L’installation et service doit être exécuté par un
qualifié installer, agence de service ou le fourmis-
seur de gaz.
Ne pas entreposer ni utiliser d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
“In the Commonwealth of Massachusetts, this product must be
installed by a licensed Massachusetts Plumber or Gas Fitter”
IMPORTANT
The Shadowlight XL is manufactured and shipped set up for LP
gas (Propane). Conversion kits (page 14) are available to convert
to natural gas or back to LP gas.
It is important to mark the fuel label accordingly so that the value
is easily identified as to which fuel it is set up for.
This appliance may be installed in an aftermarket
permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type(s) of
gas indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certified kit is used.
Cet appareil peut être installé dans un maison
préfabriquée (mobile) déjà installée à demeure si
les règlements locaux le permettent.
Cet appareil doit être utilisé uniquement avec les
types de gas indiqués sur la plaque signalétique.
Ne pas l’utiliser avec d’autres gas sauf si un kitde
conversion cerifié est installé.
2
INTRODUCTION ........................................................... 4
SPECIFICATIONS ......................................................... 5
OPERATION ................................................................... 8
How to Light the Fire ................................................ 9
How to Turn Off the Fire ......................................... 10
INSTALLATION ........................................................... 11
Clearances ............................................................... 12
Connecting to a Gas Supply .................................... 13
Converting to Natural Gas .......................................15
Converting to High Altitude ....................................17
Venting .....................................................................18
Installing into a Fireplace ........................................20
Options .................................................................... 24
MAINTENANCE .......................................................... 25
Removing the Glass ................................................. 25
Replacing the Gasket ...............................................25
Cleaning the Glass ................................................... 25
Cleaning the Log Set and Firebox ........................... 25
Convection Blower Service Access.................. ....... 26
WIRING DIAGRAM .....................................................27
PARTS LIST ....................................... ......................... 28
TROUBLE SHOOTING ................................................30
WARRANTY ................................................................. 34
TABLE OF CONTENTS
3
The installation of the ShadowLight XL Fireplace Insert
must conform with local codes, or in the absence of local
codes, with National Fuel Gas Code, ANSI Z233.1 (NFPA
54). Installer l'appareil selon les codes ou règlements
locaux, ou, en l'absence de tels règlements, selon les
Codes d'installation CAN/CGA-B149.
The ShadowLight XL Fireplace Insert may be installed
in mobile homes.
CAUTION: This appliance must be vented to the
outside.
Installation and repair of the ShadowLight XL Fireplace
Insert should be done by a qualified service person.
The appliance should be inspected before use and
at least annually by a qualified service person. More
frequent cleaning may be required due to excessive lint
from carpeting, bedding material, etc. It is imperative
that control compartments, burners, and circulating air
passageways of the appliance be kept clean. Any safety
screen or guard removed for servicing an appliance must
be replaced prior to operating the appliance.
S'ASSURER QUE LE BRÛLEUR ET LE COMPARTIMENT
DES COMMANDES SONT PROPRES. VOIR LES
INSTRUCTIONS D'INSTALLATION ET D'UTILISATION
QUI ACCOMPAGNENT L'APPAREIL.
When operating your Harman ShadowLight XL Fireplace
Insert, respect basic safety standards.
Read these instructions carefully before you attempt
to operate the heater. Failure to do so may result in
damage to property or personal injury and may void the
product warranty.
Consult with your local building code agency and insurance
representative before you begin your installation to
ensure compliance with local codes, including the need
for permits and follow-up inspections.
Observing required clearances to combustible materials,
proper connection to an approved venting system, and
the accessibility of the gas and electrical supply must
all be considered when planning the installation of a
ShadowLight XL Fireplace Insert.
Install the ShadowLight XL Fireplace Insert only in
a listed solid-fuel burning factory-built fireplace or
a masonry solid-fuel burning fireplace. The Fireplace
Insert and vent should be enclosed when installed in,
or when passing through, a living area where children
may come in contact with it.Z21.88-2002-CSA 2.33-
2002,CAN/CGA2.17.
Introduction
• Not for use with solid fuel. Not for use with air filters. Ne doit pas etre
utilise avec un combustible solide.
Also for use in mobile (manufactured) homes after home is sited.
• Tested to ANSI Z21.88-2002 / CSA2.33-2002 / CAN-CGA-2.17-M91
For use with natural gas or propane. A conversion kit, as supplied by the
manufacturer, shall be used to convert this room heater to the alternate
fuel. Pour utilisation, avec le gaz naturel et le propane. Une trousse de
conversion fournie par le fabricant doit etre utilisee pour passer d’un
combustible a l’autre.
Keep burner and control compartment clean. See installation and
operating instructions accompanying appliance. S’assurer que le bruleur
et le compartiment des commandes sont propres. Voir les instructions
d’installation et d’utilisation qui accompagnent l’appareil.
During repairs or maintenance of this unit, all sealing gaskets or high
temperature silicone seals on the heat exchanger module must be in-
spected for damage and replaced, if necessary, to prevent any leakage
of exhaust into the living areas.
Electrical Rating: 115 VAC, 60 Hz, < 1.15 AMP
MANTEL CLEARANCE: Combustible mantle up to 8” in depth must be
at least 43” above unit base.
CAUTION: Do not operate the appliance with glass removed, cracked
or broken. Replacement of panel(s) should be done by a licensed or
qualified service person.
CAUTIONNER: N’orére l’appareil avec le verre enlevé, craque ou casse.
Le remplacement du panneau(s) devrait être fait par une personne de
service qualifie ou autorise.
Manufactured by Harman Stove Company
352 Mountain House Road, Halifax, PA 17032
20 Airport Road, West Lebanon, NH 03784
A LABEL (LOCATED NEAR THE BURNER SYSTEM MOD-
ULE) STATES THE FUEL FOR WHICH THE HEATER IS
EQUIPPED.
SAFETY LABEL
WHI #
This appliance is only for use with the type of gas indicated on the rat-
ing plate and may be installed in an aftermarket, permanently located,
manufactured (mobile) home where not prohibited by local codes. See
owner’s manual for details. This appliance is not convertible for use
with other gases, unless a certified kit is used.
• Homologue Pour Le Canada
• Do not remove this label.
RATINGS
Input Rating(Btu/hr)(0-2000 ft)(0-610m)
Input Rating(Btu/hr)(2000-4500ft)(610-1375m)
Min. Input Rating(Btu/hr)
Orifices (DMS)(0-2000 ft)(0-610m)
Orifices (DMS)(2000-4500ft)(610-1375m)
Manifold Pressure (in w.c./kPa)
Min. Manifold Pressure (in w.c./kPa)
Min. Inlet Pressure (in w.c./kPa)
NATURAL
35,000
34,000
21,600
31
33
3.5/.87
1.3/.32
5.0/1.24
PROPANE
35,000
34,500
20,900
50
51
2.5
3.6/.9
11.0/2.75
CAUTION: Hot while in operation. Do not touch. Severe burns may
result. Keep children, clothing, furniture, gasoline and other liquids
having flammable vapors away.
ATTENTION: Les surfaces sont chaudes en service. Ne touchez pas.
Risque de brulure grave. Tenez les enfants, les vatements, le mobilier,
l’essence et autres liquides produisant des vapeurs inflammables B
distance.
Listed Direct Vent Gas Fireplace Heater
Radiateur Ventile
Model: ShadowLight XL Gas Fireplace Insert
4
Specifications
40”
30”
Front View
Minimum Opening Size: 29”
Inlet
Outlet
Top View
Side View
Front View
14”
13”
5
Specifications
Hi-Low Knob
On-Off-Pilot
Knob
Igniter
Blower Speed
Switch
On-Off- Thermostat
Switch
Pilot
Glass Door
Latch Handle
Leveling Bolt
Leveling Bolt
Burner Plate
Burner
Lighting
Instructions
Safety Label
Face Bolt
Face Bolt
6
Specifications
Leveling Bolt
Vent
Air Intake
On-Off
Thermostat
Switch
On-Off
Thermostat
Switch
Connector
RATINGS NATURAL PROPANE
Input Rating (Btu/hr)(0-2,000 ft)(0-610m) 35,000 BTU 35,000 BTU
Input Rating(Btu/hr)(2000-4500ft)(610-1375m) 34,000 BTU 34,500 BTU
Min. Input Rating (Btu/hr) 21,600 BTU 20,900 BTU
Orifices (DMS)(0-2000 ft)(0-610m) 31 50
Orifices (DMS)(2000-4500ft)(610-1375m) 33 51
Manifold Pressure (in w.c./kPa) 3.5 / .87 10.0 / 2.49
Minimum Manifold Pressure (in w.c./kPa) 1.3 / .32 3.6 / 0.9
Minimum Inlet Pressure (in w.c./kPa) 5.0 / 1.25 11.0 / 2.74
Maximum Output (BTU/hr)(0 to 4,500 ft.)(0 to 1,375 m)(Blower off) 27,600 28,600
7
Operation
PILOT
Door Handles
Warning
Doors Are Hot While In Operation. Wear Gloves
and Only Touch Doors On The Handles.
Lift bottom grill with index
finger and fold down to
access controls
ON-OFF/
THERMOSTAT
Switch
UP - ON
MIDDLE - OFF
DOWN - THERMOSTAT
ON
OFF
THERMOSTAT
Pilot Location Shown Above
Pull lighting instruction
plate out to view text.
Push back in before
closing grills.
Blower Speed
Switch
Piezo Igniter
Button
8
Operation
Operation
HOW TO LIGHT THE FIRE
1. STOP! Read the safety information on the front
cover.
2. If using the optional thermostat, set thermostat to
the lowest setting.
3. Turn off electric power to the appliance.
4. Turn the ON-OFF/THERMOSTAT switch to the OFF
position.
5. Push in the gas control knob slightly and turn it
clockwise to “OFF.” NOTE: THE KNOB CANNOT
BE TURNED FROM “PILOT” TO “OFF” UNLESS IT
IS PUSHED IN SLIGHTLY. DO NOT FORCE IT.
6. Wait five (5) minutes to clear out any gas. If you
then smell gas, STOP! Follow instructions on the front
cover. If you don’t smell gas, go to the next step.
7. Set the High-Low Regulator to High by turning it fully
counterclockwise.
8. Press in the gas control knob slightly and turn coun-
terclockwise to “PILOT.”
9. Find the pilot by looking at the location shown in the
picture on page 8.
10. Push the control knob fully down and hold. Im-
mediately push the red piezo ignitor button to light
the pilot. It is normal to have to push the red button
several times before the pilot ignites. Continue to hold
the control knob in for about one (1) minute after the
pilot is lit. Release the knob and it will pop back up.
Pilot should remain lit. If it goes out, repeat steps 5
through 9.
If the knob does not pop up when released, stop
and immediately call your service technician or gas
supplier.
• If the pilot will not stay lit after several tries, turn the
gas control knob to “OFF” and call your service tech-
nician or gas supplier.
• Let the pilot burn for 5 to 10 minutes prior to turning
on the main burner.
11. Turn the gas control knob counterclockwise to
“ON.”
12. Place the ON-OFF/THERMOSTAT switch in the
ON position or in the THERMOSTAT position if the
optional thermostat is used.
13. Turn on the electric power to the heater.
14. Set the optional thermostat to the desired room
temperature.
High-Low
A LABEL ON THE BURNER SYSTEM MOD-
ULE STATES THE FUEL FOR WHICH THE
HEATER IS EQUIPPED. It is not marked at
the factory since it can be converted.
DURING INSTALLATION THIS LABEL MUST
BE MARKED FOR THE TYPE OF FUEL IT
WILL USE. (PROPANE OR NATURAL GAS)
Detailed lighting instructions can be lo-
cated above the safety label. See picture
on page 16.
9
Operation
15. Set the High-Low Regulator to desired setting: Turn
fully counterclockwise for High and fully clockwise
for Low.
NOTE: An odor, resulting from the initial heating of new
materials in your heater, is not unusual during the
first fire, and in most cases will disappear after an
hour or two.
HOW TO TURN OFF THE FIRE
1. If using optional thermostat, set thermostat to the
lowest position.
2. Turn off the electric power to the appliance.
3. Turn the ON-OFF/THERMOSTAT switch to the OFF
position.
4. Push in the gas control knob slightly and turn it
clockwise to “OFF.”
NOTE: The knob cannot be turned from “PILOT” to
“OFF” unless it is pushed in slightly. Do not force it.
AIR SHUTTER ADJUSTMENT
The adjuster can be accessed with a phillips screw
driver just above the valve . Turn the adjuster clockwise
to increase flame height and counterclockwise to de-
crease. See above left. Adjusting the flames too high
will cause them to have black tips and cause sooting.
Sooting can cause the glass to get dirty.
Warning: The unit and adjuster may be hot. Wear
gloves and arm protection if making adjustments while
in operation.
PILOT FLAMES
If pilot flames are less than shown at left, have your
service technician increase the pilot flame height.
Air Shutter
Adjustment
Normal Flame pattern. Note: Flames will vary in height and
position depending on the placement and the amount of
ember wool.
Pilot Flame Size
Pressing the ignitor button should produce a spark between
the ignitor electrode and the pilot where shown above.
Pilot
Ignitor
Electrode
Spark
10
Installation
Only For Qualified Installers
Packing List
Inside the Insert Box
ShadowLight XL Insert
Log set
Bag of rock wool
Owners Manual
Restrictor Plates
Inside Face Box
ShadowLight XL Face
Right Door
Left Door
Hardware Pack
11
Installation
Only For Qualified Installers
Installation
Due to high temperatures, the ShadowLight XL
Fireplace Insert should be located out of traffic
and away from furniture and draperies.
Children and adults should be alerted to the
hazards of high surface temperatures and should
stay away to avoid burns or clothing ignition.
Young children should be carefully supervised
when they are in the same room as the Shadow-
Light XL Gas Fireplace Insert.
Clothing or other flammable materials should
not be placed on or near the ShadowLight XL.
Surveiller les enfants. Garder les vêtements,
les meubles, l'essence ou autres liquides à
vapeur inflammables lin de l'appareil.
CLEARANCES
The following clearances to combustibles must be
observed:
Unit to mantel 8” or smaller or
combustible trim, unprotected ... 13" (305 mm)
In addition to these clearances, adequate acces-
sibility clearance for servicing and proper operation
must be maintained.
Clearance from top of unit to
mantel and combustible trim,
unprotected
13”
8”
13”
In the Commonwealth of Massachusetts,
this product must be installed by a licensed
Massachusetts Plumber or Gas Fitter”
Only use Authorized Harman Service
or Repair parts when working on your
Shadowlight XL gas fireplace insert.
12
Installation
Only For Qualified Installers
Making The Connection
The gas inlet is located on the bottom right side
of the fireplace. The inlet fitting is 1/2” male flare fitting
designed for 1/2” stainless flex pipe. This fitting can be
removed to provide 3/8” female pipe thread.
A separate gas shut-off valve and a 1/8” N.P.T.
plugged tapping should be installed immediately up-
stream of the connection to the appliance.
The ShadowLight XL Direct Vent Gas Heater must
be disconnected from the gas supply piping during any
pressure testing of that system at pressures in excess
of 1/2 psig (3.5 kPa).
The ShadowLight XL gas control valve must be
in the OFF position during any pressure testing of the
gas supply system at pressures equal to or less than
1/2 psig (3.5 kPa).
WARNING: To avoid pipe compounds from enter-
ing into the gas train, apply compounds only to male
pipe threads and do not apply compound to the first
two threads.
CAUTION: TEST ALL JOINTS FOR LEAKS BE-
FORE OPERATING.
Gas Pressure Requirements:
Correct gas pressure and the use of a properly
sized gas supply line are essential for the safe and ef-
ficient performance of this appliance. Make sure that
the plumber or gas supplier checks the gas supply line
and gas pressure at installation.
NOTE: Improper gas pressure can affect heater
performance, flame color, or cause pilot outage.
Natural Gas:
Maximum inlet pressure 7.0” w.c. (1.74 kPa)
Minimum inlet pressure 5.0” w.c. (1.25 kPa)
Gas manifold pressure 3.5” w.c. (0.87 kPa)
LP Gas:
Maximum inlet pressure 13” w.c. (3.24 kPa)
Minimum inlet pressure 11” w.c. (2.74 kPa)
Gas manifold pressure 10” w.c. (2.49 kPa)
DO NOT USE THIS HEATER IF ANY PART HAS
BEEN UNDER WATER, EXPOSED TO MOISTURE,
OR SHOWS SIGNS OF CORROSION. IMMEDIATELY
CALL A QUALlFlED SERVICE TECHNICIAN TO IN-
SPECT THE HEATER AND REPLACE ANY PART OF
THE CONTROL SYSTEM AND ANY GAS CONTROL
WHICH HAS BEEN UNDER WATER.
Gas Line
CONNECTING THE SHADOWLIGHT XL
FIREPLACE INSERT TO A GAS SUPPLY
Test Class
Note: Stove is built for propane. A conversion
must be done to accomodate natural gas.
Do not connect the venting to the ue of a
chimney that serves a separate solid-fuel
burning appliance.
13
Installation
Only For Qualified Installers
Natural Gas Kit Part No. 1-00-00384
LP Kit Part No. 1-00-00385
Conversion label
Pilot Orifice
Main Orifice #31 (Nat. Gas)
Main Orifice #50 (LP)
Valve Conversion Module
Conversion
Instructions
These kits are only for use in the
ShadowLight XL Insert.
Inside Diameter
Note: The higher the orifice number the smaller the
hole in the tip. For example, a number 52 orifice has
a larger hole than a number 60 orifice.
“This conversion kit shall be installed by a qualified
service agency in accordance with the manufacturers
instructions and all applicable codes and requirements
of the authority having jurisdiction. If the information in
these instructions is not followed exactly, a fire, explosion
or production of carbon monoxide may result causing
property damage, personal injury or loss of life. The
qualified service agency is responsible for the proper
installation of this kit. The installation is not proper and
complete until the operation of the converted appliance
is checked as specified in the owner instructions sup-
plied with the kit.”
Cer equipenent de conversion sera installe par une
agence qualifiee de service conformement aux instruc-
tions du fabricant et toutes exigencies et codes appli-
cables de l’autorises avoir la jurisdiction. Si l’information
dans cette Instruction n’est pas suivie exactement, un
feu, explosion ou production de protoxyde de carbone
peut resulter le dommages causer de propriete, perte
ou blessure personnelle de vie. L’agence qualifiee de
service est esponsable de l’installation proper de cet
equipement. L’installation n’est pas proper et complete
jusqu’a l’operation de l’appareil converti est cheque
suivant les criteres etablis dans les instructions de pro-
prietaire provisionnees avec l’equipement.
Burn Only the Fuel for Which the Heater is
Equipped
This Conversion Kit Shall Be Installed By A
Qualified Service Agency.
The ShadowLight XL Fireplace Insert will burn either
natural gas or propane, but requires a change over
kit for converting to natural gas.
The label located on the inner stove base must be
marked for the type of fuel the unit will use at the time
of installation.
Converting to Natural Gas
Caution: Before proceeding with the conversion,
the gas supply must be shut off prior to
disconnecting the electrical power.
LP and Natural Gas Conversion Kits
Do not stike glass or close door with excessive
force. Breakage of glass and/or damage to door
may result.
14
Installation
Only For Qualified Installers
Door Latches
Remove door by pulling latches out as shown and
pulling the bottom of the door out from the unit about
3”. Then lift the door slightly up and off the hooks.
Door Hooks
1
Remove air plate by lifting it up about 3 inches and
then out of firebox. Be careful not to damage side
brick panels
Converting to Natural Gas
The pilot must be placed in accordance with the above
sketch for proper burner ignition.
Pilot
Burner
2
3
4
Remove log. Next, remove screw, washer and
spacer from the center of the rear brick panel. Using
one hand, gently push the side brick/relief door open
slightly and using the other pull the top of the rear
brick panel forward and remove it.
Remove the screws mounting the intake air deflector and
lift it from the firebox. Next locate the screw holding the
burner tube to the firebox floor and remove it. Now the #50
LPG burner orifice can be removed using a 1/2” deep well
socket and replaced with a # 31 natural gas orifice.
Remove screw holding pilot air deflectors, and the
deflectors, to allow access to the pilot tower. using a 7/16”
wrench, take out the LP orifice and replace it with the
natural gas orifice. Reassemble components adjusting
pilot air deflectors allowing burner tube to slide over
them and into place. Pilot orfices are marked NG and LP
appropriately.
15
Installation
Only For Qualified Installers
Remove three screws to change knob assembly. Install NG knob assembly in place of the LP assembly. Be
sure screws are tight.
5
Place conversion sticker (provided in Kit) on the valve. This
is to permanently mark the valve that it has been converted
to Natural Gas. This label is important in the event that
the valve is ever removed and mixed in with other valves.
Reassemble all components removed during the conversion
process.
6
Mark the proper box on the fuel label with a
permanent marker. Note: If no conversion is
made, the box for propane must still be marked.
7
Safety Label
Use soap and water and/or a gas detector to
check for leaks before lighting the pilot.
8
When installation has been completed, verify the gas inlet
and manifold pressures are within specifications. The safety
label, located inside the bottom of the unit, will have the
information needed to verify correct operation. To read
the safety label, pull the label out away from the unit. Be
sure to use the information for the type of gas that it will
be using.
You must check the unit for any gas leaks using soapy
water or an electronic style leak detector.
16
Specifications
Door Latches
Remove door by pulling latches out as shown and
pulling the bottom of the door out from the unit about
3”. Then lift the door slightly up and off the hooks.
Door Hooks
1
Remove air plate by lifting it up about 3 inches and
then out of firebox. Be careful not to damage side
brick panels
Converting to High Altitude
2
3
4
Remove log. Next, remove screw, washer and
spacer from the center of the rear brick panel. Using
one hand, gently push the side brick/relief door open
slightly and using the other pull the top of the rear
brick panel forward and remove it.
Remove the screws mounting the intake air deflector and lift
it from the firebox. Next locate the screw holding the burner
tube to the firebox floor and remove it. Now the burner
orifice can be removed using a 1/2” deep well socket and
replaced with orifice required for type of fuel being used.
Refer to safety label for orifice size.
If this is a new unit, the Natural Gas Conversion Kit must be
used when installing the Natural Gas High Altitude Kit.
17
Installation
Only For Qualified Installers
Preliminary steps to prepare for the installation of
the ShadowLight XL Fireplace Insert
Remove the chimney cap if one exists so that the flue
may be cleaned and the venting installed.
Remove any existing hearth accessories such as glass
doors, spark screens, andirons, and grates.
Clean the chimney thoroughly to remove ash, soot,
and any obstructions, and then clean ash, soot, dust,
and debris from the fireplace.
The damper must be locked open to allow the 3"
venting to pass through. If it is necessary to modify
the damper area to allow passage of the venting, the
modifications should be allowed under local codes.
Confirm any planned changes with local building
officials.
Use Only Approved Venting
Observe local codes when venting the ShadowLight
XL. If no local codes exist, follow ANSI Z21.88-2002
installation code.
Do not connect the venting to the flue of a chimney that
serves a separate solid-fuel burning appliance.
The venting manufacturer's installation instructions
must be followed exactly.
The most efficient venting systems are those that have
a minimum number of bends and minimal horizontal
runs.
WARNING: Operation of this heater when not
connected to a properly installed and maintained
venting system can result in carbon monoxide (CO)
poisoning and possible death.
Exhaust restrictor plates must be installed depending
on type of gas and chimney height. See page 20 to
determine restrictor.
Venting
“Warning: Failure to position parts in accordance
with these diagrams or failure to use only parts
specifically approved with this appliance may
result in property damage or personal injury.”
18
Installation
Only For Qualified Installers
Use Only Approved Venting
This appliance has been tested and is listed for
installation with Simpson Duravent GS and Duraflex
AL venting components. The warranty will be voided,
and serious fire, health, or other safety hazards may
result from any of the following actions:
• Installation of any damaged Simpson Duravent
component.
• Unauthorized modification of the Simpson Du-
ravent System.
• Installation of any component part not manufac-
tured or approved by Simpson Duravent.
• Installation other than as instructed by Simpson
Duravent and the appliance manufacturer.
Consult your local building codes before begin-
ning the installation, and follow the manufacturer’s
instructions exactly. The Simpson Duravent venting
components listed below are approved for use with
the ShadowLight XL Direct Vent Gas Insert.
Flashing
Chimney Liner Termination
Kit. Includes flashing.
Stock # 923GK
High Wind Cap
Stock# 991
Chimney Cap Components
Duraflex AL - Flexible Aluminum Pipe Lengths
Size Length Stock #
3” 25’ 2270
3” 35’ 2280
3” 50’ 2290
Typical Chimney
Tile Liner
Vent Pipe
Air Intake Pipe
Uncoil the three inch aluminum chimney liners on the
ground and measure to make sure the pipes are long
enough. Mark one of the liners at both ends with paint
and use it for the exhaust side connection. Once they
are in the chimney it allows easier identification of
intake and exhaust connections.
Flashing
Figure__
Air Intake
Vent
Minimum vertical vent pipe length is 10 Feet.
Maximum horizontal distance is 36”.
A bead of silicone goes
between the top of
the tile liner and the
flashing to seal the cap
to the chimney
19
Installation
Only For Qualified Installers
Remove the screw, washer and spacer from the
center of the rear brick panel. Using one hand,
gently push out on the side brick /relief door to allow
clearance for removing the rear brick panel.
Door Latches
Open the glass door by pulling out on the 2 latches
located on the bottom of the door frame. Pull the
bottom out a couple of inches and lift the door off
of the stove body and set safely out of the way.
Remove the bag of rock wool, packaging materials
and log set from inside the firebox.
Skip steps 3 thru 5
if intake / exhaust adapter does
not need removed for in
stallation.
Feed chimney liners down the chimney and through
the damper.If the fireplace opening does not allow
enough room to connect the flue liners to the stove
it is necessary to separate the exhaust/ intake pipe
adapter from the stove body.
Approximately 4 inches clearance above the top of
the glass door is needed to allow connection of the
liners. This must be determined by the installer.
1
2
3
4
Remove 2 screws holding exhaust cover plate onto
the rear of the firebox and remove cover.
Venting and Installation
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34

Harman Stove Company ShadowLight XL Manuel utilisateur

Catégorie
Cheminées
Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues