1. IMPORTANT NOTE 04
1.1. Compliance with international standards 04
2. INTRODUCTION 04
3. INSTALLATION 05
3.1. Location and assembly 05
3.2. Mains connection 05
3.3. Audio input connections 05
3.4. Audio output connections 06
3.5. Remote control options 06
4. OPERATION AND USAGE 07
4.1. Operation and default mode 07
4.2. Special active source selection mode and setting adjustments 08
4.3. AUTO STANDBY Function 09
4.4. LED indicators 09
4.5. Micro switches on the rear panel 10
4.6. Lock mode 10
4.7. Restore default settings and update firmware 10
5. CLEANING 11
6. LIST OF FUNCTIONS 12
7. DIAGRAM OF FUNCTIONS 13
8. TECHNICAL CHARACTERISTICS 50
9. BLOCK DIAGRAM 51
10. CONFIGURATION DIAGRAM 52
All numbers subject to variation due to production tolerances. NEEC AUDIO BARCELONA S.L. reserves the right to make
changes or improvements in manufacturing or design which may affect specifications.
4
1. IMPORTANT NOTE
Congratulations! You have acquired the result of painstaking design and manufacturing. Thank you
for having chosen our CA120HZ micro amplifier.
In order to get the optimum operation and efficiency from your product, it is VERY IMPORTANT -
before you plug anything - to read this manual very carefully and take seriously into account all
considerations specified within it.
We strongly recommend that its maintenance be carried out by our Authorised Technical Services.
1.1. Compliance with international standards
The CA120HZ micro amplifier complies with the following international standards:
EN55103-1 Electromagnetic Compatibility.
Product family standard for audio, video, audio-visual and entertainment lighting control apparatus
for professional use
Part 1: Emission
EN55103-2 Electromagnetic Compatibility.
Product family standard for audio, video, audio-visual and entertainment lighting control apparatus
for professional use
Part 2: Immunity
EN60065 Audio, video and similar electronic apparatus. Safety requirements
Complying with the requirements of directives 73/23/EC and 2004/108/EC
2. INTRODUCTION
The CA120HZ is a very small mono amplifier with high impedance output (70/100V) and a multitude
of remote control functions (RS-232 serial port, infrared receiver, 0-10 VDC remote control port), and is
ideal for integrating audiovisual applications with other devices: educational classes, meeting rooms and
multimedia presentations, business premises, etc.
Main characteristics:
1 x 120 W RMS @ 70/100V amplifier
Universal external power supply
AUTO STANDBY function: in the absence of an audio signal the unit automatically goes into
STANDBY mode, minimising power consumption
Lightweight, silent, high-performance amplifier (fan-free convection cooling)
1 switchable balanced mic / unbalanced line input, with high quality microphone preamplifier, phantom
power supply, noise gate and “talkover” function or priority over the rest of input
2 stereo lines (unbalanced)
2-band independent tone control (Bass, Treble) for the microphone / line 3 and line 1&2 input
connection.
Auxiliary output for liaison with other amplifiers or external audio devices
Local control by digital rotary knob (“encoder”)
Remote control by infrared remote control
Remote control by WPmVOL or WPmVOL-SR (0-10 VDC) wall panel
RS-232 control port, compatible with EclerCOMM software (free) and control protocol CA-NET
MUTE port to silence the entire unit by closing external contact
5
3. INSTALLATION
3.1. Location and assembly
The CA120HZ is suitable for installation on a wall or under a surface (table, shelf, cupboard, etc.),
thanks to its design and layout of its connectors, controls and LED indicator lights.
3.2. Mains connection
The amplifier is powered by alternating current through its external power source: 100-240 VAC
and 50-60 Hz.
This apparatus must be earthed through its mains cable (earth resistance, Rg = 30, or lower).
The environment should be as dry and dust free as possible. Do not expose the unit to rain or water
splashes. Do not place liquid containers or incandescent objects like candles on top of the unit.
Should any work or connection / disconnection task be done, always disconnect the unit from the
mains supply. There are no elements that can be manipulated by the user inside the amplifier.
To avoid buzzing, do not allow the power cable to intertwine with the shielded cables that
transport the audio signal.
3.3. Audio input connections
The CA120HZ accepts two types of signals in its input channels:
Microphone (MIC): has a balanced Euroblock or jack type connection, ready to accept a
signal level between -20dBV y 50dBV, with adjustable sensitivity with the ADJ control
NOTE: the microphone input has a phantom power supply to power condenser
microphones, activated by internal bridge (see section 10. CONFIGURATION
DIAGRAM).
Line signals (LINE1, LINE2, LINE3): they have unbalanced minijack or double RCA type
stereo connections. They are prepared for input of between -6dBV and 0dBV, with input
sensitivity that can be adjusted by internal port (see section 10. CONFIGURATION
DIAGRAM). You can connect signals from CD players, radio tuners, mixing consoles,
media players, the audio outputs of PCs and tablets, etc. to these connections.
NOTE: Turntables CANNOT BE CONNECTED directly to this device because none of the inputs
have an RIAA preamp.
The CA120HZ has the following operating modes according to the input sources selected as
active:
LINE1: only the LINE1 input is sent to the mix bus to be amplified and routed to the OUTPUT in
mono format
LINE2: only the LINE2 input is sent to the mix bus to be amplified and routed to the OUTPUT in
mono format
LINE3/MIC: only the microphone (MIC) / line (LINE3) input is sent to the mix bus to be amplified
and routed to the OUTPUT in mono format
LINE1 + LINE3/MIC: the LINE1 and LINE3/MIC inputs are mixed, amplified and routed to the
OUTPUT in mono format. If the TALKOVER function is enabled, the LINE3/MIC input will
attenuate the LINE1 signal when the activation threshold is reached
LINE2 + LINE3/MIC: the LINE2 and LINE3/MIC inputs are mixed, amplified and routed to the
OUTPUT in mono format. If the TALKOVER function is enabled, the LINE3/MIC input will
attenuate the LINE2 signal when the activation threshold is reached
6
Select one of the 5 work modes in special selection mode with the rotating knob on the front (see
section 4.2. Special selection mode of active sources and adjusting settings for details of the full
procedure).
3.4. Audio output connections
The amplified OUTPUT uses a Euroblock connector.
The connection cable between the CA120HZ output and the speakers should be of good quality,
with a suitable cross section and as short as possible.
The output operates in mono mode only (L+R summed in case of active stereo input).
Additionally, the CA120HZ has an unamplified auxiliary output (AUX OUT) which makes it possible
to connect it to amplifiers or with other external devices. The auxiliary output AUX OUT has a line level
signal (0dBV) which is an unamplified replica of the signal delivered to the OUTPUT terminals.
3.5. Remote control options
REMOTE port: the RJ-45 REMOTE type connector allows the connection of a WPmVOL or
WPmVOL-SR (control 0-10 VDC) wall control panel to adjust the general output volume
and/or to select one of the five active work source modes (LINE1, LINE2, LINE3/MIC, LINE1
+ LINE3/MIC, LINE2 + LINE3/MIC). The connection is made by a standard CAT5 cable
between the WPmVOL or WPmVOL-SR wall panel and the REMOTE CA120HZ connector.
Because there is a CA120HZ WPm type control as well as other types of controls (front
knob, infrared control and serial port control) the most recent adjustments by any of these
methods will prevail. For example, if an active source is selected and/or a volume adjustment
is made using the WPmVOL-Sr wall panel connected to the REMOTE port, and then these
settings are adjusted using the front control, the adjustment made with the frontal control will
prevail. In this case, when the wall panel position is adjusted again, the CA120HZ will change
to the values indicated, and so on and so forth.
MUTE port: The MUTE connector makes it possible to connect a power free contact to totally
silence the CA120HZ if an external device works on it (example: a emergencies and
centralised evacuation warning system).
RS-232 port: the serial communication port RS-232 allows remote management of the
CA120HZ from a computer through the EclerCOMM software or CA-NET protocol from an
external control system supporting this protocol. See the CA-NET protocol manual for
detailed information on the connection and syntax of the commands supported. The
connection has the following specifications:
o Baud rate: 9600 (fixed, without auto negotiation)
o Data bits: 8
o Parity: None
o Stop bits: 1
o Flow control: None
Receiver IR: the built-in IR receiver gives general volume control of the CA120HZ and its
MUTE ON / OFF function from the REVO-IR remote control included with the unit.
WIRING RS-232 DB9
RS-232 CA120HZ
DB9
Tx
Pin 2 (RxD)
Rx
Pin 3 (TxD)
Gnd
Pin 5 (Signal Gnd)
7
4. OPERATION AND USAGE
4.1. Start up and default mode
Start up the CA120HZ by connecting the equipment to an external power source to which the DC
24V connector of the CA120HZ has already been connected. The LED indicator ON/STBY immediately
lights up on the front panel. We recommend you turn on all the devices in the following order: sound
sources, mixer, equalisers, active filters and processors and, finally power amplifiers. Powering off
should be done by following the exact reverse sequence. Following this order, the introduced noise due
to turning on or switching off the devices will not affect those further on in the chain and will be inaudible.
The system defaults to volume adjustment mode. In this mode, the VOL/MUTE knob on the front
panel acts on the general output volume of the CA120HZ. This controller has a maximum of 64 steps
between the unit's minimum and maximum volume. When turned, it will adjust the volume while the LED
LEVEL light is flashing. When the controller is turned to the left or to the right, this flashes while the
output volume increases or decreases. The light stops flashing when it reaches either end of the scale
and it is no longer possible to increase or decrease the volume of the unit.
Quickly press the VOL/MUTE controller to activate/deactivate the mute function of the unit
(MUTE ON/OFF). The MUTE LED lights when the mute function is activated.
If you adjust the volume using the infrared remote control, the LED LEVEL y MUTE visual
indicators are exactly the same as those seen when adjusting these with the knobs on the front panel.
8
4.2. Special active source selection mode and setting adjustments
Use the knob on the front panel to access special modes for selecting active sources and adjusting
levels and equalization (bass and treble). You can access these modes by holding in the knob for a certain
time and then turning it. By adjusting the level of each source you can mix the signal from the microphone
or line (LINE3/MIC) and another line (LINE1 or LINE2), and the result of this mix will be controlled by the
general output volume of the unit together, in other words, respecting the relative levels set of each source.
The full procedure for accessing and operating in these special modes and the options available in
each are set out in the following graph:
Notes:
1. If the device is in special mode for 10 seconds and the front knob is not touched, the equipment
automatically reverts to VOL/MUTE mode.
2. In tone control mode, when you turn the knob in either direction it flashes fast while the gain of
the affected tone increases. When either end of the scale is reached (-10 ó +10dB) or when it
goes through the centre point (0dB) it flashes more slowly.
9
4.3. AUTO STANDBY Function
The AUTO STANDBY function (idle or low consumption mode) means you can install the
CA120HZ in inaccessible places and leave the device connected to the mains power supply permanently
because when no signal is detected, it automatically goes into standby mode, saving energy.
To enable AUTO STANDBY use the micro switch with the same name on the rear panel of the unit
(see section 7. DIAGRAM OF FUNCTIONS). When activated, if there is no audio signal in any of the
inputs (or the signal is very weak, below the activation threshold), the CA120HZ automatically goes into
STANDBY mode, and the ON/STBY on the front panel of the device goes orange. When a valid audio
signal is detected in any of the inputs, the CA120HZ leaves standby mode and starts operating normally
again and the ON/STBY LED goes green.
When you enable AUTO STANDBY mode with the micro switch (position ON) one of two things
happens:
a) There is NO audio signal in the inputs. Result: the amplifier immediately goes into AUTO
STANDBY mode
b) There is an audio signal in the inputs. Result: the amplifier stays active
When the amplifier goes into AUTO STANDBY mode, all the LED indicators go out with the
exception of ON/STBY. If the amplifier is in STANDBY mode and you turn the VOL/MUTE knob to
adjust the volume or activate the MUTE function, the LED lights will come on for a short time then go out
again. Remember that the first acting on the VOL/MUTE knob, this will only reset the LED indicators,
and will not change any of the settings.
When the unit is a special mode (source selection or setting adjustment) the LED indicators will
not go out even if the amplifier is in AUTO STANDBY mode.
4.4. LED indicators
SP: The signal presence or SP LED indicator shows that there is a signal in the amplifier
input. This lights up when the input level reaches the established detection threshold.
CLIP: The saturation or CLlP LED indicator comes on when the signal delivered to the
speakers is close to the amplifier's clipping or saturation level. Input signals should be set to
ensure the CLIP (saturation or cut off) indicators never stay on, but that they do so at most to
the beat of the lowest sound frequencies. Otherwise the amplified signal will be distorted with
low quality and low intelligibility.
Note: If the input signal is too high, the CLIP indicator lighting up very frequently over a
short time interval (a few seconds), the amplifier may go into protection mode, being muted to
return to normal operation in a short time
MUTE: This lights up when the MUTE function is active (silent mode)
ON/STBY: the green light comes on when the equipment is in normal operating mode and it
goes orange when it is in standby or low consumption mode (STANDBY).
LEVEL: This flashes when you adjust the general level of the device. It also lights up during
special adjustment modes, input levels (see section 4.2. Special active source selection
mode and setting adjustments)
BASS: This light up during special adjustment modes bass frequencies (see section 4.2.
Special active source selection mode and setting adjustments)
TREBLE: This light up during special adjustment modes, treble frequencies (see section 4.2.
Special active source selection mode and setting adjustments)
LINE1, LINE2, LINE3/MIC: These lights up during special modes, selection of active sources
and adjustments (see section 4.2. Special active source selection mode and setting
adjustments)
10
4.5. Micro switches on the rear panel
REMOTE: Turn on (ON) the remote control from the WPmVOL or WPmVOL-SR wall panel
connected to the REMOTE port.
NOISE GATE: Turn on (ON) or turn off the noise gate function for the LINE3/MIC input. When
this function is active the microphone input is muted whilst there is no signal above the function
activation threshold, so the equipment rejects background noise captured by the microphone
connected to it.
TALKOVER: On or off according to the priority of the LINE3/MIC input over the line inputs
(LINE1 or LINE2). When the TALKOVER function is on, the LINE3/MIC signal will attenuate
the selected line (LINE 1 or 2) when the activation threshold set is reached.
AUTO STANDBY: Switch the AUTO STANDBY function on (ON) or off. When the function is
on, the CA120HZ will automatically go into STANDBY or low consumption mode in the
absence of audio signals in its inputs.
LINE3/MIC: input selection between LINE and MIC3 (line level input from RCA connectors or
microphone level input from Euroblock connector)
HPF: frequency selection (50 or 70 Hz) for the unit's high-pass filter
4.6. Lock mode
To switch the CA120HZ lock mode on or off hold in the VOL/MUTE control for 10 seconds from the
VOL/MUTE mode. The LED SETTING indicators will flash 3 times to indicate that lock mode is now on.
When in lock mode the device cannot be managed using the VOL/MUTE control (it will flash three times to
show that it is in that mode when you turn the knob). This will protect the equipment from unwanted
handling until it is restored to normal operation after holding the VOL/MUTE control in for a further 10
seconds (the LED SETTING indicators will flash twice to show that the lock mode is off).
Note: once lock mode is activated it will stay activated even when the equipment is turned off and
on again. It will stay in lock mode until the VOL/MUTE control is held in for 10 seconds again.
4.7. Restore default settings and update firmware
If you would like to restore the CA120HZ to factory settings, follow this procedure:
1. Unplug the equipment then press and hold the knob in.
2. Plug back the unit without releasing the knob. The MUTE LED indicator will flash.
3. Wait a few seconds and then switch the CA120HZ off again.
4. The next time you turn it on, the factory settings will be in the memory.
Note: for instructions on how to update the unit's firmware, see the product web page at
www.ecler.com,
where you will find the update software utility and instructions on how to proceed.
11
5. CLEANING
The CA120HZ must not be cleaned with solvents or abrasive substances which may damage the
prints. Clean using a cloth moistened in water and a neutral liquid detergent, then dry with a clean cloth.
Under no circumstances allow water to enter any of the orifices in the equipment.
12
6. LIST OF FUNCTIONS
1. LEVEL indicator light
2. BASS indicator light
3. TREBLE indicator light
4. LINE1 indicator light
5. LINE2 indicator light
6. MIC indicator light
7. VOL/MUTE knob
8. SP input signal presence indicator light
9. CLIP indicator light
10. MUTE indicator light
11. ON/STBY on or standby indicator light
12. REMOTE, remote control receiver
13. HPF micro switch
14. MIC/LINE3 micro switch
15. AUTO STANDBY micro switch
16. TALKOVER micro switch
17. NOISE GATE micro switch
18. REMOTE micro switch
19. Remote control by protocol CA-NET, RS-232
20. RJ-45, REMOTE connector
21. MUTE remote control
22. DC24V power connector
23. OUTPUT amplified output
24. AUX OUT
25. RCA input line, LINE1
26. Mini jack input line, LINE2
27. RCA input line, LINE3
28. Microphone input, MIC
29. Microphone jack, MIC
30. MIC input sensitivity setting
31. Volume down key
32. Volume up key
33. Mute key
13
7. DIAGRAM OF FUNCTIONS
14
15
MANUAL DE INSTRUCCIONES
1. NOTA IMPORTANTE 16
1.1. Conformidad con normativas internacionales 16
2. INTRODUCCIÓN 16
3. INSTALACIÓN 17
3.1. Ubicación y montaje 17
3.2. Conexión a red eléctrica 17
3.3. Conexiones de audio de entrada 17
3.4. Conexiones de audio de salida 18
3.5. Opciones de control remoto 18
4. OPERACIÓN Y USO 19
4.1. Puesta en funcionamiento y modo por defecto 19
4.2. Modos especiales de selección de fuentes activas
y ajuste de sus parámetros 20
4.3. Función AUTO STANDBY 21
4.4. Indicadores LED 21
4.5. Microinterruptores del panel posterior 22
4.6. Modo de bloqueo 22
4.7. Restaurar valores por defecto y actualización de firmware 22
5. LIMPIEZA 23
6. LISTA DE FUNCIONES 24
7. DIAGRAMA DE FUNCIONES 25
8. CARACTERÍSTICAS TÉCNICAS 50
9. DIAGRAMA DE BLOQUES 51
10. DIAGRAMA DE CONFIGURACIÓN 52
Todos los datos están sujetos a variación debida a tolerancias de producción. NEEC AUDIO BARCELONA S.L. se reserva el
derecho de realizar cambios o mejoras en la fabricación o diseño que pudieran afectar las especificaciones.
16
1. NOTA IMPORTANTE
¡Enhorabuena!. Vd. posee el resultado de un cuidadoso diseño y una esmerada fabricación.
Agradecemos su confianza por haber elegido nuestro micro amplificador CA120HZ.
Para conseguir la máxima operatividad del aparato y su máximo rendimiento es MUY
IMPORTANTE, antes de su conexión, leer detenidamente y tener muy presentes las consideraciones que
se especifican en este manual.
Para garantizar el óptimo funcionamiento de este aparato, recomendamos que su mantenimiento
sea llevado a cabo por nuestros Servicios Técnicos autorizados.
1.1. Conformidad con normativas internacionales
El micro amplificador CA120HZ está conforme a las siguientes normativas internacionales:
EN55103-1 Compatibilidad Electromagnética.
Norma de familia de Productos para aparatos de uso profesional de sonido, vídeo, sistemas
audiovisuales y para el control de iluminación para espectáculos
Parte 1: Emisión
EN55103-2 Compatibilidad Electromagnética.
Norma de familia de Productos para aparatos de uso profesional de sonido, vídeo, sistemas
audiovisuales y para el control de iluminación para espectáculos
Parte 2: Inmunidad
EN60065 Aparatos de audio, vídeo y aparatos análogos. Requisitos de seguridad
Cumpliendo los requisitos de las directrices 73/23/CEE y 2004/108/CE
2. INTRODUCCIÓN
El CA120HZ es un amplificador mono con salida en alta impedancia (70/100V) de muy reducido
tamaño y multitud de funciones de control remoto (puerto serie RS-232, receptor de infrarrojos, puerto de
control remoto 0-10 VDC), siendo una opción ideal en aplicaciones de integración audiovisual con otros
dispositivos: clases de enseñanza, salas de reuniones y presentaciones multimedia, locales comerciales,
etc.
Características principales:
Amplificador de 1 x 120 W RMS @ 70/100V
Fuente de alimentación externa universal
Función AUTO STANDBY: en caso de ausencia de señal de audio la unidad pasa automáticamente al
modo de reposo o STANDBY, quedando su consumo minimizado
Amplificador de alto rendimiento ligero y silencioso (refrigeración por convección, sin ventilador)
1 entrada conmutable de micrófono balanceada / línea no balanceada, con preamplificador de
micrófono alta calidad, alimentación Phantom, puerta de ruido y función de “talkover” o prioridad sobre
el resto de entradas
2 entradas de línea estéreo (no balanceadas)
Control de tonos de 2 bandas (Bass, Treble) independiente para la entrada de micrófono / línea y la
entrada 1&2 de línea
Salida auxiliar para enlace con otros amplificadores o dispositivos de audio externos
Control local mediante control giratorio digital (“encoder”)
Control remoto mediante mando a distancia por infrarrojos
Control remoto mediante panel mural WPmVOL o WPmVOL-SR (0-10 VDC)
Puerto de control RS-232, compatible con el software EclerCOMM (gratuito) y con el protocolo de
control CA-NET
Puerto MUTE para silenciamiento total de la unidad mediante cierre de contacto externo
17
3. INSTALACIÓN
3.1. Ubicación y montaje
El CA120HZ admite instalación en pared o bien sobre o bajo una superficie (mesa, estantería,
mueble, etc.), gracias a su diseño y a la disposición de sus conectores, controles e indicadores LED.
3.2. Conexión a red eléctrica
El amplificador se alimenta con corriente alterna mediante su fuente de alimentación externa: 100-
240 VAC y 50-60 Hz.
La fuente de alimentación del amplificador debe conectarse a una toma de tierra en condiciones
(resistencia de tierra, Rg = 30, o menor). El ambiente de trabajo deberá ser seco y estar totalmente
libre de polvo. No exponga el aparato a la caída de agua o salpicaduras. No ponga encima objetos con
líquido ni fuentes de llama desnuda, como velas.
En caso de requerir alguna intervención y/o conexión-desconexión del amplificador debe
desconectarse previamente la alimentación. En el interior del amplificador no existen elementos
manipulables por el usuario.
Debe evitarse que el cable de red se entremezcle con los cables blindados que transportan la señal de
audio, ya que ello podría ocasionar zumbidos.
3.3. Conexiones de audio de entrada
El CA120HZ admite dos tipos de señales en sus canales de entrada:
Micrófono (MIC): dispone de conexión balanceada tipo Euroblock o jack, preparada para
admitir un nivel de señal entre -20dBV y 50dBV, con sensibilidad ajustable mediante su
control ADJ
NOTA: la entrada de micrófono dispone de alimentación Phantom para alimentar
micrófonos de condensador, activable mediante puente interno (ver sección 10.
DIAGRAMA DE CONFIGURACIÓN).
Señales de línea (LINE1, LINE2, LINE3): disponen de conexión estéreo no balanceada
tipo minijack o doble RCA. Están preparadas para admitir señales entre -6dBV y 0dBV,
con sensibilidad ajustable mediante puente interno (ver sección 10. DIAGRAMA DE
CONFIGURACIÓN). Es posible conectar a ellas señales de reproductores de CD,
sintonizadores de radio, consolas de mezcla, reproductores multimedia, salidas de audio de
ordenadores y tablets, etc.
NOTA: NO PUEDEN CONECTARSE directamente a este aparato platos giradiscos ya que
ninguna de las entradas dispone de preamplificador tipo RIAA.
El CA120HZ permite los siguientes modos de trabajo, en función de qué fuentes de entrada
sean seleccionadas como activas:
LINE1: sólo la entrada LINE1 es enviada al bus de mezcla para ser amplificada y entregada en
la salida OUTPUT en formato mono
LINE2: sólo la entrada LINE2 es enviada al bus de mezcla para ser amplificada y entregada en
la salida OUTPUT en formato mono
LINE3/MIC: sólo la entrada de micrófono (MIC) / línea (LINE3) es enviada al bus de mezcla para
ser amplificada y entregada en la salida OUTPUT en formato mono
LINE1 + LINE3/MIC: las entradas LINE1 y LINE3/MIC son mezcladas, amplificadas y
entregadas en la salida OUTPUT en formato mono. Si la función TALKOVER se encuentra
activa, la LINE3/MIC atenuará a la de LINE1 al superar el umbral de activación
LINE2 + LINE3/MIC: las entradas LINE2 y LINE3/MIC son mezcladas, amplificadas y
entregadas en la salida OUTPUT en formato mono. Si la función TALKOVER se encuentra
activa, la LINE3/MIC atenuará a la de LINE2 al superar el umbral de activación
18
La selección de uno de los 5 modos de trabajo se realiza mediante el modo especial de
selección del control giratorio frontal (ver sección 4.2. Modos de selección de fuentes activas y
ajuste de sus parámetros para conocer el procedimiento completo).
3.4. Conexiones de audio de salida
La salida amplificada OUTPUT está provista de conector Euroblock.
El cable de conexión que une la salida del CA120HZ y los altavoces, deberá ser de buena calidad,
de suficiente sección y lo más corto posible.
La salida funciona únicamente en modo mono (misma señal, suma L+R cuando exista entrada
estéreo activa).
Adicionalmente, el CA120HZ dispone de una salida auxiliar (AUX OUT) no amplificada, que
permite enlazarlo con amplificadores u otros dispositivos externos. La salida auxiliar AUX OUT
proporciona una señal de nivel de línea (0dBV) que es una réplica sin amplificar de la señal entregada en
los terminales OUTPUT.
3.5. Opciones de control remoto
Puerto REMOTE: el conector tipo RJ-45 REMOTE permite la conexión de un panel de
control mural tipo WPmVOL o WPmVOL-SR (control 0-10 VDC) para el ajuste del volumen
general de salida y/o la selección de uno de los 5 modos de fuentes activas de trabajo
(LINE1, LINE2, LINE3/MIC, LINE1 + LINE3/MIC, LINE2 + LINE3/MIC). El conexionado se
realiza mediante un cable CAT5 estándar entre el panel mural WPmVOL o WPmVOL-SR y
el conector REMOTE del CA120HZ.
Al coexistir en un CA120HZ un control tipo WPm con otros tipos de control (control
giratorio frontal, mando de infrarrojos o control vía puerto serie) prevalecerán siempre los
últimos ajustes realizados por uno u otro método. Por ejemplo, si se realiza una selección de
fuentes activas y/o un ajuste de volumen mediante un panel mural WPmVOL-SR conectado
al puerto REMOTE, y a continuación se modifican dichos parámetros mediante el control
frontal, prevalecerá el ajuste realizado mediante dicho control frontal. En este caso, cuando
se vuelva a modificar la posición del panel mural, el CA120HZ retomará los valores que éste
le indique, y así sucesivamente.
Puerto MUTE: el conector MUTE permite la conexión de un cierre de contacto externo libre
de potencial para silenciar totalmente el CA120HZ en caso de que un dispositivo externo
actúe sobre él (ejemplo: un sistema de avisos para emergencias y evacuación centralizado).
Puerto RS-232: el puerto de comunicación serie RS-232 permite la gestión remota del
CA120HZ desde un ordenador mediante el software EclerCOMM o el protocolo CA-NET
desde un sistema de control externo que soporte dicho protocolo. Vea el manual del
protocolo CA-NET para obtener información completa acerca de los detalles de la conexión y
la sintaxis de los comandos soportados. Las especificaciones de la conexión serie son las
siguientes:
o Baud rate: 9600 (fijo, sin autonegociación)
o Data bits: 8
o Parity: None
o Stop bits: 1
o Flow control: None
Receptor IR: el receptor IR integrado permite el control del volumen general del CA120HZ y
de su función de MUTE ON / OFF desde el mando a distancia REVO-IR incluido con la
unidad.
CABLEADO RS-232 DB9
RS-232 CA120HZ
DB9
Tx
Pin 2 (RxD)
Rx
Pin 3 (TxD)
Gnd
Pin 5 (Signal Gnd)
19
4. OPERACIÓN Y USO
4.1. Puesta en funcionamiento y modo por defecto
El encendido del CA120HZ se realizará mediante la conexión a la red de la fuente de
alimentación externa previamente conectada al conector DC 24V del CA120HZ. Inmediatamente se
iluminará el indicador LED ON/STBY del panel frontal. Es muy recomendable poner en marcha todos
los aparatos siguiendo la secuencia siguiente: fuentes de sonido, unidad de mezclas, ecualizadores,
filtros activos y procesadores y, finalmente, amplificadores de potencia. El apagado de los aparatos
debe realizarse en la secuencia inversa. Siguiendo este orden los transitorios producidos por el
encendido o apagado de los aparatos no afectarán a los siguientes en la cadena, permaneciendo
inaudibles.
Por defecto, la unidad se encontrará en el modo de ajuste de volumen. En este modo el control
giratorio VOL/MUTE del panel frontal actúa sobre el volumen general de salida del CA120HZ. Este
control dispone de un máximo de 64 pasos entre el volumen mínimo y el máximo de la unidad. Al girarlo
se modificará dicho volumen mientras parpadea el indicador LED LEVEL. Al girar el control en uno u
otro sentido, éste parpadea mientras se aumenta o reduce el volumen de salida, quedando iluminado
fijo cuando se llega a uno de ambos extremos y no es posible aumentar o reducir más el volumen de la
unidad.
Si se pulsa brevemente el control VOL/MUTE se actúa sobre la activación / desactivación de la
función de enmudecimiento de la unidad (MUTE ON/OFF), iluminándose el indicador LED MUTE
cuando se halle activo el enmudecimiento.
Si se realiza un ajuste de volumen mediante el mando a distancia por infrarrojos las indicaciones
visuales mediante los LEDs LEVEL y MUTE son exactamente las mismas que para el ajuste mediante
el control giratorio del panel frontal.
20
4.2. Modos especiales de selección de fuentes activas y ajuste de sus parámetros
Mediante el control giratorio frontal es posible entrar en modos especiales para la selección de las
fuentes activas y el ajuste de sus parámetros de nivel y ecualización (graves y agudos). La entrada y
navegación en dichos modos se realiza mediante pulsaciones de determinada duración del control
giratorio y su posterior giro. El ajuste de nivel de cada fuente permite realizar una mezcla entre una señal
de micrófono o línea (LINE3/MIC) y otra de línea (LINE1 o LINE2) y que el resultado de dicha mezcla sea
afectado por el volumen general de salida de la unidad de manera conjunta, es decir, respetando los
niveles relativos establecidos para cada fuente.
El procedimiento completo para entrar y operar en estos modos especiales, así como las opciones
disponibles en cada uno de ellos, se encuentran reflejados en el gráfico siguiente:
Notas:
1. Si, estando en cualquier modo especial, transcurren 10 segundos sin actuar sobre el control
giratorio frontal, se retornará automáticamente al modo por defecto de ajuste de VOL/MUTE.
2. En el modo de ajuste de tonos, al girar el control en uno u otro sentido, éste parpadea
rápidamente mientras se aumenta la ganancia del tono afectado, parpadeando más lentamente
al llegar a uno de los extremos (-10 ó +10dB) o bien al pasar por el punto central (0dB).
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

Ecler CA120HZ Manuel utilisateur

Catégorie
Destinataire
Taper
Manuel utilisateur