Hayward aqua trol Le manuel du propriétaire

Catégorie
Accessoires de piscine hors terre
Taper
Le manuel du propriétaire
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Aqua Trol
Above Ground Pool Chlorine Generator
Owner’s Manual
AQ-TROL-RJ-CUL
Hayward Industries
400 Connell Drive, Suite 6100
Berkeley Heights, NJ 07922
Phone: (908) 355-7995
www.haywardcanada.com
092577 RevD
®
\Contents
Introduction............................................1
Pool Chemistry........................................2
Installation ............................................6
Operation...............................................8
System Maintenance.............................11
Troubleshooting....................................12
Warranty................................................14
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
IMPORTANT SAFETY INSTRUCTIONS
When using this electrical equipment, basic safety precautions should always be
followed, including the following:
READ AND FOLLOW ALL INSTRUCTIONS
Disconnect all AC power during installation.
Warning - To reduce the risk of injury, do not permit children to use this
product unless they are closely supervised at all times.
WARNING - Risk of Electric Shock. Connect only to a grounding type
receptacle protected by a ground-fault circuit-interrupter (GFCI). Contact
a qualied electrician if you cannot verify that the receptacle is protected
by a GFCI.
Do not bury cord. Locate cord to minimize abuse from lawn mowers,
hedge trimmers, and other equipment.
WARNING - To reduce the risk of electric shock, replace damaged cord
immediately.
WARNING - To reduce the risk of electric shock, do not use extension
cord to connect unit to electric supply; provide a properly located outlet.
A green colored terminal marked "Earth Ground" is located inside the
wiring compartment. To reduce the risk of electric shock, this terminal
must be connected to the grounding means provided in the electric sup-
ply service panel with a continuous copper wire equivalent in size to the
circuit conductors supplying the equipment.
One bonding lug for US models (two for Canadian models) is provided
on the external surface. To reduce the risk of electric shock, connect
the local common bonding grid in the area of the swimming pool, spa,
or hot tub to these terminals with an insulated or bare copper conductor
not smaller than 8 AWG US / 6 AWG Canada.
All eld installed metal components such as rails, ladders, drains, or
other similar hardware within 3 meters of the pool, spa or hot tub shall
be bonded to the equipment grounding bus with copper conductors not
smaller than 8 AWG US / 6 AWG Canada.
SAVE THESE INSTRUCTIONS
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
1
Introduction
The Aqua Trol® is an automatic chlorine generation system for above ground pools. The operation
requires a low concentration of salt (sodium chloride) in the pool water at levels low enough that it
normally will not be tasted. The Aqua Trol automatically sanitizes your pool by converting the salt into
free chlorine which kills bacteria and algae in the pool through a process called electrolysis. Because
chlorine will revert back to sodium chloride after killing the bacteria, these reactions will continuously
recycle virtually eliminating the need to add sanitizing chemicals to your pool. The only time you
may need to add more salt to the pool is when water is replenished due to backwashing, draining,
or splashing (not evaporation).
The Aqua Trol is designed to handle the purification needs of the average residential above ground
swimming pool of up to 18,000 gallons (67,500 liters). The actual amount of chlorination required
to properly sanitize a pool varies depending upon bather load, rainfall, temperature, and the pool’s
cleanliness.
NOTE: Before installing this product as part of a saline water purification system in an above-ground
pool with an immediately adjacent natural stone patio/decking, a qualified stone installation specialist
should be consulted regarding the appropriate type, installation, sealant (if any) and maintenance
of stone used around a saline pool with electronic chlorine generator in your particular location and
circumstances.
NOTE: The use of dry acid (sodium bisulfate) to adjust pool pH is discouraged especially in arid
regions where pool water is subject to excessive evaporation and is not commonly diluted with fresh
water. Dry acid can cause a buildup of by-products that can damage your chlorinator cell.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
2
Pool Chemistry
As with any pool, it is important that you maintain chemical makeup of the pool water. The table be-
low summarizes the levels that are recommended by The Association of Pool and Spa Professionals
(APSP). The only special requirement for the Aqua Trol is the salt level and stabilizer. It is important
to maintain these levels in order to prevent corrosion or scaling and to ensure maximum enjoyment
of the pool. Test your water periodically. Your local pool store can provide you with the chemicals
and procedures to adjust the water chemistry. Be sure to tell the pool store that you are using an
Aqua Trol chlorine generator.
Saturation index
The saturation index (Si) relates to the calcium and alkalinity in the water and is an indicator of the
pool water “balance”. Your water is properly balanced if the Si is 0 ±.2. If the Si is below -0.2, the
water is corrosive and plaster pool walls will be dissolved into the water. If the Si is above +0.2,
scaling and staining will occur. Use the equation and chart below to determine the saturation index.
Si = pH + Ti + Ci + Ai - TDS
Hardness
Calcium
75
100
125
150
200
250
300
400
600
800
Total Dissolved
Solids
Total
alkalinity
°C °F Ti Ci Ai TDS
12
16
19
24
29
34
39
53
60
66
76
84
94
102
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.5
1.6
1.7
1.8
1.9
2.0
2.1
2.2
2.4
2.5
75
100
125
150
200
250
300
400
600
800
1.9
2.0
2.1
2.2
2.3
2.4
2.5
2.6
2.8
2.9
0-1000
1001-2000
2001-3000
3001-4000
4001-5000
12.10
12.29
12.35
12.41
12.44
Use: Measure the pH of the pool water, the temperature, water hardness, total alkalinity,
and total dissolved solids. Use the table above to determine Ti, Ci, Ai, and TDS in the
formula shown above. If the Si is equal to 0.2 or more, stains may appear. If the Si is
equal to -0.2 or less, corrosion or deterioration may occur.
Corrosion Stain
Ok
-0.2 0.2
CHEMICAL IDEAL LEVELS
Salt Normal Salt Mode - 2700 to 3400 ppm
Low Salt Mode - 1200 to 1800 ppm
Free Chlorine 1.0 to 3.0 ppm
pH 7.2 to 7.6
Cyanuric Acid
(Stabilizer) 20 to 30 ppm (if necessary)
Total Alkalinity 80 to 120 ppm
Calcium Hardness 125 to 250 ppm
Metals 0 ppm
Saturation Index -0.2 to 2.0 best
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
3
Salt Level
Use the chart on page 4 to determine how much salt in pounds (or Kgs) needs to be added to reach
the recommended levels. Use the equations below (measurements are in feet/gallons and meters/
liters) if pool size is unknown.
The Aqua Trol features two modes of operation; Normal Salt Mode and Low Salt Mode. In general,
Normal Salt mode generates more chlorine than Low Salt Mode but there are other factors that
affect total chlorine production (see “Operation” on page 11). For lower demands, or if there will
be supplemental sanitization, Low Salt Mode may be desired. The Aqua Trol is shipped from the
factory in Normal Salt Mode and no selection is required if this is the desired mode. If you would
prefer to use Low Salt Mode, it must be selected within the Diagnostic Display (page 11).
Normal Salt Mode: The ideal salt level is between 2700-3400 ppm (parts per million) with 3200
ppm being optimal. If the level is low, determine the number of gallons in the pool and add salt
according to the chart on page 5. A low salt level will reduce the efficiency of the Aqua Trol and
result in lower chlorine production. A high salt level can cause the Aqua Trol to shutdown and may
begin to give a salty taste to your pool (generally, the salt will begin to be tasted at a level of about
3500-4000 ppm).
Low Salt Mode: The ideal saline level is between 1200-1800 ppm (parts per million) with 1500
ppm being optimal. If the level is low, determine the number of gallons in the pool and add salt
according to the chart on page 6. A low saline level will reduce the efficiency of the Aqua Trol and
result in lower chlorine production. A high saline level can cause the Aqua Trol to shutdown.
The salt in your pool is constantly recycled and the loss of salt throughout the swimming season
should be small. This loss is due primarily to the addition of water because of splashing, back-
washing or draining (because of rain). Salt is not lost due to evaporation.
Type of Salt to Use
It is important to use only sodium chloride (NaCl) that is 99% pure. This is common food quality or
water softener salt available in 40-80 lb. bags at your local Hayward dealer. It is also acceptable
to use water conditioning salt pellets, however, it will take longer for them to dissolve. Do not use
rock salt, salt with more than 1% yellow prussiate of soda, salt with more than 1% of anti-caking
additives, or iodized salt.
How to Add or Remove Salt
Turn the filter pump on and add the salt directly into the pool. Brush the salt to speed up the dissolv-
ing process--to not allow the salt to sit in a pile on the bottom of the pool. Run the filter pump for 24
hours with the suction coming from the main drain (use the pool vacuum if there is not main drain) to
allow the salt to evenly disperse throughout the pool. The salt display may take 24 hours to respond
to the change in salt concentration. The only way to lower the salt concentration is to partially drain
the pool and refill with fresh water.
Gallons Liters
(pool size in feet) (pool size in meters)
Rectangular
Round
Oval
Diameter x Diameter x
Average Depth x 5.9
Length x Width x
Average Depth x 6.7
Length x Width x
Average Depth x 7.5
Diameter x Diameter x
Average Depth x 785
Length x Width x
Average Depth x 893
Length x Width x
Average Depth x 1000
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
4
Normal Salt Mode
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
5
Low Salt Mode
12,000 14,000 16,000 18,000
Current salt
level
(45000) (52,500) (60,000) (67,500)
ppm
0150
(68)
175
(80)
200
(91)
225
(103)
200 130
(59)
152
(69)
173
(79)
195
(89)
400 110
(50)
128
(58)
147
(67)
165
(75)
600 90
(41)
105
(48)
120
(55)
135
(61)
800 70
(32)
82
(37)
93
(42)
105
(48)
1000 50
(23)
58
(27)
67
(30)
75
(34)
1200 30
(14)
35
(16)
40
(18)
45
(20)
1400 10
(5)
12
(5)
13
(6)
15
(7)
10,000
8,000
(37,500)
100 125
(45) (57)
87 108
(39) (49)
73 92
(33) (42)
60 75
(27) (34)
47 58
(21) (27)
33 42
(15) (19)
20 25
(9) (11)
78
(3) (4)
(30,000)
Ideal Ideal Ideal Ideal Ideal Ideal
1500
Pounds and (Kg) Of Salt Required For 1500 ppm
Pool Size in Gallons and (Liters)
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
6
Stabilizer (Cyanuric Acid)
Always check stabilizer (cyanuric acid), when checking salt. These levels will most likely decline
together.
Installation
Installation must be performed in accordance with Local and NEC codes.
Preparing Pool Water
Refer to page 2 for recommended chemical levels. The pool’s chemistry must be balanced BEFORE
activating the Aqua Trol. NOTE: If the pool does not have new water, add 1 quart (1 liter) of metal
remover and 1 quart (1 liter) of non-copper based algaecide to the pool, per manufacturers instruc-
tions. This ensures a quick, troublefree transfer to the Aqua Trol system.
Mounting
The Aqua Trol is contained in a raintight enclosure that is suitable for outdoor mounting. The control
must be mounted a minimum of 5 ft. (2 meters) horizontal distance (or more if local codes require)
from the pool.
The control is designed to mount vertically on a flat surface. Because the enclosure also acts as a
heat sink (disperses heat from inside the box), it is important not to block the four sides of the control.
Do not mount the Aqua Trol in a panel or tight enclosed area.
Aqua Trol
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
7
Plumbing
Unscrew the hose adaptor from the pool return jet fitting and, in its place, screw in the right-angle
cell mounting adaptor. Note that this installation does NOT require a flow switch--however it is very
important that the cell be mounted vertically directly below the return jet in order to allow the gases
produced in the cell to naturally dissipate in the pool. Attach the cell to the union and then use the
fittings supplied to attach the lower end of the cell to either the hose or rigid PVC pipe coming from
the pools filtration system. Tighten all union nuts BY HAND for a watertight seal.
Wiring
Power must be shut off at the circuit breaker before performing any wiring. Be sure to follow Local
and NEC/CEC electrical codes. The Aqua Trol has been designed to easily wire into typical above
ground pool systems. To provide safe operation, the Aqua Trol must be properly grounded and
bonded.
Input Power
Models with the standard 120 VAC line cord should be plugged into a GFCI receptacle. See diagram
below.
SUBPANEL
GROUND
NEUTRAL
GFCI
OUTLET
AQUA TROL
(AQ-TROL-RJ-CUL)
Aqua Trol
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
8
Bonding
A lug used for bonding is attached to the bottom of the Aqua Trol enclosure. Connect to the pool
bonding system using minimum 6AWG copper wire if required by code.
Electrolytic Cell
Route the cell cable through the enclosure cutout and connect to the Aqua Trol.
Operation
Controls
The pool filter pump should run long enough to circulate the entire volume of pool water each day.
This will vary depending on pump size, pool plumbing and pool size. Consult a local pool store to
help determine the appropriate run time for your pool.
Main Switch
AUTO: For normal operation, the Main Switch should be left in the AUTO position. In this position
the Aqua Trol will produce chlorine according to the “Desired Output %” adjustment setting for the
entire filtering/pumping cycle.
SUPER CHLORINATE: When you have an abnormally high bather load, a large amount of rain,
a cloudy water condition, or any other condition which needs a large amount of purification to be
introduced, put the Main Switch in the SUPER CHLORINATE position. This electronically “super chlo-
rinates” (shocks) the water for 24 hours (filter pump must be on during this time) or until the power
has been turned off, whichever comes first. At the end of the super chlorinate time, be sure to put
the switch back into the AUTO position.
OFF: The OFF position prevents the Aqua Trol from energizing the electrolytic cell. In this position
there is no chlorine generation. NOTE: To service any of the pool equipment or the Aqua Trol, turn
the power off at the circuit breaker.
Bonding lug to
pool bonding system
INPUT POWER
120 VAC linecord
to GFCI receptacle/breaker
Cutout for
cell cable
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
9
Desired Output % adjustment knob
This setting is used to control the amount of chlorine the Aqua Trol generates. Raise this setting to
increase chlorine level and lower it to decrease chlorine level.
Indicator LED’s
POWER When illuminated, the Aqua Trol has input power.
GENERATING This LED is on steady during normal operation. When flashing, the pool water is too
hot or cold to operate.
SUPER CHLORINATE Illuminates during Super Chlorination. See description above.
NO FLOW When illuminated, the flow switch has detected no flow and the Aqua Trol has stopped
generating chlorine. A flashing LED indicates a 15/60 second time delay period.
CHECK SALT When flashing, the salt level is below 2700 ppm in Normal Salt Mode or below 1200
ppm in Low Salt Mode. Aqua Trol is generating at low efficiency. When illuminated steady, the salt
level is too low for operation and Aqua Trol has shut down. Before adding large quantities of salt, it
is advisable to have your salt level professionally checked.
HIGH SALT When illuminated, the salt level is too high and Aqua Trol has shut down.
INSPECT CELL A flashing indicator signifies that either the cell efficiency is reduced or that it is
time for regularly scheduled cell inspection. In either case, inspect the cell and clean if necessary.
Pressing the “diagnostic” button next to the display for 3 seconds will stop the flashing LED. When il-
luminated steady, cell efficiency is greatly reduced and the Aqua Trol has stopped producing chlorine.
Inspect, clean or replace if necessary.
Diagnostic Displays
Sequential pushes of the small “diagnostic” button next to the LCD display will cause the Aqua Trol
to display the following information:
1. Pool temperature (xx degrees Fahrenheit or Celsius)
2. Cell voltage (typically xx.x volts when chlorine is being generated, otherwise 30-35V)
3. Cell current (typically x.xx amps when chlorine is being generated, otherwise 0 amps)
4. Desired Output % (“0P” -- “100P” depending on knob position )
5. Instant salinity ( -xxxx ppm or -x.xx grams/Liter)
6. Product name sent to the display (“AL-6” signifies “Aqua Trol” (STD), (“AL-7” signifies “Aqua
Trol Return-Jet”)
7. Software revision level (r1.xx)
8. Salt Mode (nSlt = Normal Salt Mode, lSlt=Low Salt Mode)
On the 9th push of the button the display will revert back to the default salt display. Also, if the button
is not pushed for 30 seconds, the display will revert back to the standard salt display.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
10
Salt Mode
Aqua Trol is shipped in Normal Salt Mode requiring your pool’s ideal salt level to be 3200 ppm. To
change to Low Salt Mode (1500 ppm ideal level), perform the following steps:
1. Slide the Main Switch from “Off” to the “Auto” position.
2. Push the Diagnostic button repeatedly until “nSlt” appears on the display. This indicates that the
unit is in Normal Salt Mode.
3. Slide the Main Switch from “Auto” to “Super Chlorinate” and back to “Auto”. The display should
toggle to “lSlt” which indicates Low Salt Mode.
4. Do not touch any buttons for 30 seconds and the display will revert back to the current Salt
Display.
Salt Display
Refer to the Water Chemistry section for recommended saline levels as well as how to add/remove
salt. The Salt Display shows the average saline level of the pool water. The factory default display
is in English units (ppm). If Metric units (grams per liter) are preferred, follow the procedure under
Temperature Display. When the AquaRite is displaying grams per liter, the readout will show a decimal
point. (ex. 1.50 g/L = 1500 ppm).
Temperature Display
The Temperature Display shows the current temperature of the pool water. The factory default display
is in ºF. Both the Temperature Display and the Salt Display can be programmed to display in Metric
units. To display temperature in ºC and saline level in g/l, perform the following steps:
1. Slide the Main Switch from “Off” to the “Auto” position.
2. Push the Diagnostic button once and the current temperature will appear on the display.
3. Slide the Main Switch from “Auto” to “Super Chlorinate” and back to “Auto”. The display should
now show the temperature in Celsius and salt in g/L.
4. Do not touch any buttons for 30 seconds and the display will revert back to the current Salt
Display.
Instant Salinity
The Instant Salinity display is the measured saline level of the pool water at that moment. If salt has
recently been added, the Instant Salinity may show the change while the Salt Display (average saline
level) may take some time before the changes can be seen. Under these circumstances, you may
want to “update” the Salt Display to the new Instant Salinity value. This action will clear the Salt Display
and substitute the Instant Salinity value. To do this, follow the steps below:
1. Slide the Main Switch from “Off” to the “Auto” position.
2. Push the Diagnostic button repeatedly until the instant salinity value “-xxxx” (English) or “-x.xx”
(Metric) appears on the display.
3. Slide the Main Switch from “Auto” to “Super Chlorinate” and back to “Auto”. The Salt Display will
now be updated to the Instant Salinity value.
4. Do not touch any buttons for 30 seconds and the display will revert back to the current Salt
Display.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
11
Operation
By understanding how the Aqua Trol operates, you’ll be sure to use it more effectively for maximum
convenience and performance. Assuming that the water chemical levels are in the recommended
range, there are three factors that you can control which directly contribute to the amount of chlorine
the Aqua Trol will generate:
1. filter time each day (hours)
2. the amount of salt in the pool
3. the “Desired Output %” setting
To find the optimum “Desired Output %” setting, start at a fairly high setting and work downward. It
will take a few days of adjustments to find the ideal setting for your pool/spa. Once determined, it
should only take minor adjustments, if at all, to compensate for differing salt levels due to splashing,
backwashing, rain, etc. Because the production of chlorine is affected by water temperature, it is
important to check chlorine levels during periods of unusually high or low pool water temperatures.
The Aqua Trol control will not produce chlorine at temperatures below 50º F. If your pool will be
below this temperature for any length of time, you must chlorinate manually.
NOTE: After the ideal “Desired Output %” setting has been found, you may need to raise the setting
when the pool water temperature increases significantly, when there is higher than normal bather
load or when your chlorinator cell ages. You may need to lower the setting when the pool water
temperature decreases significantly or there are long periods of inactivity.
System Maintenance
To maintain maximum performance, it is recommended that you open and visually inspect the cell
every 3 months or after cleaning your filter. The Aqua Trol will remind you to do this by flashing the
“Inspect Cell” LED after approximately 500 hours of operation. After you inspect the cell (and clean,
if necessary) press the small “diagnostic” button next to the display for 3 seconds to stop the flashing
“Inspect Cell” LED and start the timer for the next 500 hour inspection period.
The Aqua Trol electrolytic cell has a self cleaning feature incorporated into the electronic control’s
logic. In most cases this self cleaning action will keep the cell working at optimum efficiency. In
areas where water is hard (high mineral content) and in pools where the water chemistry has been
allowed to get “out of balance”, the cell may require periodic cleaning. The “Inspect Cell” LED will
indicate if cell efficiency is decreased and servicing is necessary. If the “Inspect Cell” LED remains
on after a thorough cleaning, the cell may be worn and require replacement.
Servicing and Cleaning the Aqua Trol Cell
Turn off power to the Aqua Trol before removing the electrolytic cell. Once removed, look inside
the cell and inspect for scale formation (light colored crusty or flaky deposits) on the plates and for
any debris which has passed through the filter and caught on the plates. If no deposits are visible,
reinstall. If deposits are seen, use a high pressure garden hose and try to flush the scale off. If this
is not successful, use a plastic or wood tool (do not use metal as this will scratch the coating off the
plates) and scrape deposits off of the plates. Note that a buildup on the cell indicates that there is an
unusually high calcium level in the pool (old pool water is usually the cause). If this is not corrected,
you can expect to have to periodically clean the cell. The simplest way to avoid this is to bring the
pool chemistry to the recommended levels as specified.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
12
Mild Acid Washing: Use only in severe cases where flushing and scraping will not remove the
majority of deposits. To acid wash, turn off power to Aqua Trol. Remove cell from piping. In a clean
plastic container, mix a 4:1 solution of water to muriatic acid (one gallon of water to one quart of
muriatic acid). ALWAYS POUR ACID INTO WATER - NEVER POUR WATER INTO ACID. Be sure to wear
rubber gloves and appropriate eye protection. The level of the solution in the container should just
reach the top of the cell so that the wire harness compartment is NOT submerged. It may be helpful
to coil the wiring before immersing the cell. The cell should soak for a few minutes and then rinse
with a high pressure garden hose. If any deposits are still visible, repeat soaking and rinsing. Replace
cell and inspect again periodically.
Winterizing
The Aqua Trol electrolytic cell and flow detection switch will be damaged by freezing water just as
your pool plumbing would. In areas of the country which experience severe or extended periods of
freezing temperatures, be sure to drain all water from the pump, filter, and supply and return lines
before any freezing conditions occur. The electronic control is capable of withstanding any winter
weather and should not be removed.
Spring Start-up
DO NOT turn the Aqua Trol on, until the pool water chemistry has been brought to the proper levels.
This information can be found on page 2.
Troubleshooting
Common Problems and Solutions
1. “Power” LED not on
Check to make sure 120 VAC input power is connected to the Aqua Trol control. Verify input voltage
with a voltmeter. If there is input power, the fuse may have blown. The Aqua Trol is protected by a
20 amp mini ATO fuse located on the circuit board above the cell connector.
2. “Generating” LED not on
The Aqua Trol only generates chlorine when the filter pump is running, the main switch is in the
“AUTO” or “SUPER CHLORINATE” position, and none of the red fault LEDs are illuminated.
3. “Generating” LED flashing
The temperature of the pool water is too high or low to operate. You can override this by switching
the main switch to SUPER CHLORINATE. The Aqua Trol will run at maximum output for the remainder
of the current pump cycle or 24 hours, whichever comes first.
4. “Check Salt” LED illuminated or flashing
Take a sample of your pool water to your local Authorized Aqua Rite Dealer Hayward and have the salt
level tested. No salt test is completely accurate and the test results may vary from the salt level on
the Aqua Trol display. If salt level is low, add salt according to chart on page 4 or 5.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
13
5. “High Salt” LED illuminated
Check salt level in pool/spa. If salt level is too high, lower salt level by draining some of the pool
water out of the pool and replace with fresh water. Continue until the salt concentration is at recom-
mended levels.
6. “Inspect Cell” LED flashing
Inspect and clean cell according to directions on page 11. When done, press the “diagnostic” button
for 3 seconds to stop the “Inspect Cell” LED flashing.
7. “Inspect Cell” LED illuminated
Remove and inspect the cell for scale. If the cell is scaled, follow the directions on page 11 for cell
cleaning. If the pool has the proper amount of salt and the “Inspect Cell” LED is still illuminated, the
cell may be worn and need replacement.
8. Possible causes of little or no free chlorine residual
- Aqua Trol switch in OFF position.
- Desired Output % adjustment setting is too low.
- Low stabilizer (Cyanuric Acid).
- Filter pump switched off or filter pump time too short (8 hours for average size pools, more for
large pools)
- Salt level too low (Check Salt LED on).
- Salt level too high (High Salt LED on).
- Very warm pools increase chlorine demand--increase Desired Output % or filter run time.
- Cold water (below 50ºF) causes Aqua Trol to stop generating (Generating LED flashing).
- Excessive scaling on cell.
- High level of Nitrogen in pool water.
- “Yellow Out” or similar treatment recently used. Some yellow algae treatments will use chlorine
at a very high rate and deplete the residual free chlorine. Manually shock the pool if indicated in
the directions on the algae treatment. It still may be a matter of days before the pool returns to
“normal” and chlorine tests will show the desired 1-3 ppm free chlorine reading.
9. “-Pcb-” displayed and all 4 red/yellow LEDs are illuminated.
A possible Printed Circuit Board fault has been detected.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
14
LIMITED WARRANTY (effective 03/01/12) Hayward warrants its Pro Logic, OnCommand and E-Com-
mand pool automation products as well as its Aqua Rite, Aqua Rite Pro, Aqua Plus and SwimPure chlo-
rination products to be free of defects in materials and workmanship, under normal use and service,
for a period of three (3) years. Hayward also warrants its Aqua Trol chlorination products to be free
of defects in materials and workmanship, under normal use and service for a period of one (1) year.
These warranties are applicable from the initial date of purchase on private residential swimming pools
in the US and Canada. Installations of product for use on commercial pools in the US and Canada is
covered for a period of one (1) year for defects in materials and workmanship. Hayward warrants all
accessories and replacement parts for the above-identified pool automation and chlorination products
for a period of one (1) year. Accessories also include remotes, actuators, base stations, temperature
sensors, flow switches and chemistry probes. Each of these warranties is not transferable and applies
only to the original owner.
Hayward shall not be responsible for cartage, removal, repair or installation labor or any other such
costs incurred in obtaining warranty replacements or repair.
Proof of purchase is required for warranty service. If written proof of purchase is not provided, the
manufacturing date code will be the sole determinant of the date of installation of the product. To obtain
warranty service or repair, please contact the place of purchase or the nearest Hayward authorized war-
ranty service center. For more information on authorized service centers please contact the Hayward
Technical Service Support Center (61 Whitecap Road, North Kingstown RI, 02852) or visit the Hayward
web site at www.hayward.com.
WARRANTY EXCLUSIONS:
1. Material supplied or workmanship performed by others in process of installation.
2. Damage resulting from improper installation including installation on pools larger than the product
rating.
3. Problems resulting from failure to install, operate or maintain the product(s) in accordance with the
recommendations contained in the owners manual(s).
4. Problems resulting from failure to maintain pool water chemistry in accordance with the recommen-
dations in the owners manual(s).
5. Problems resulting from tampering, accident, abuse, negligence, unauthorized repairs or alterna-
tions, fire, flood, lightning, freezing, external water, degradation of natural stone used in or immediately
adjacent to a pool or spa, war or acts of God.
6. Use of a non-genuine Hayward replacement salt chlorination cell on any Hayward automation or
chlorination product will void the warranty for that product.
The express limited warranty above constitutes the entire warranty of Hayward Pool Products with
respect to its products and is in lieu of all other warranties expressed or implied, including warran-
ties of merchantability or fitness for a particular purpose. In no event shall Hayward Pool products be
responsible for any consequential, special or incidental damages of any nature. Some states do not
allow a limitation on how long an implied warranty lasts, or the exclusion of incidental or consequential
damages, so the above limitation may not apply to you. This warranty gives you specific legal rights,
and you may also have other rights, which vary from state to state.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Aqua Trol
Générateur de chlore électronique
Guide d’utilisation
AQ-TROL-RJ-CUL
®
\Table des Matières
Introduction..............................................1
Composition chimique de l’eau.....................2
L’installation...............................................6
Fonctionnement.........................................8
Entretien du Système.................................11
Dépannage..............................................12
Garantie.................................capot arrière
UTILISEZ UNIQUEMENT DES PIÈCES DE REMPLACEMENT D’ORIGINE HAYWARD
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
IMPORTANTES CONSIGNES DE SÉCURITÉ
Observez en tout temps les consignes de sécurité de base, que voici quand
vous utilisez cet équipement électrique:
LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS
Coupez tous les circuits d’alimentation c.a. pendant l’installation.
Avertissement : Pour réduire les risques de blessures, ne permettez pas
aux enfants d’utiliser ce produit sauf s’ils sont sous surveillance étroite en
tout temps.
Une borne de couleur verte marquée « Earth Ground » (mise à la terre) est
située à l’intérieur du compartiment de câblage. Pour réduire les risques
de choc électrique, cette borne doit être branchée au dispositif de mise
à la terre fourni dans le panneau de distribution électrique avec un l de
cuivre en continu de dimension équivalente au conducteur d’alimentation
de l’équipement.
AVERTISSEMENT - Risque de choc électrique. Connectez uniquement à
une prise protégée par un disjoncteur différentiel-(GFCI)
Ne pas enterrer le câble d’alimantation. Mettez-le à l’abri des tondeuses à
gazon, des taille-haies et autres équipements.
AVERTISSEMENT - Pour réduire le risque de choc électrique, remplacer
immédiatement tout câble endommagé.
AVERTISSEMENT - Pour réduire le risque de choc électrique, ne pas uti-
liser de rallonge électrique pour brancher l’appareil à une alimentation;
prévoir une prise de courant correctement située.
Une cosse de métallisation est fournie pour les modèles américains (deux
pour les modèles canadiens) sur la face extérieure. Pour réduire les ris-
ques de choc électrique, branchez la grille locale de métallisation com-
mune dans la zone de la piscine, du spa ou de la cuve thermale à ces
bornes avec un conducteur isolé ou en l de cuivre nu de calibre minimal
de 8 AWG US / 6 AWG Canada.
Les éléments métalliques installés sur le terrain, comme les rails, les
échelles, les drains ou autres ferrures semblables, à l’intérieur 3 m de
la piscine, du spa ou de la cuve thermale doivent être raccordés au con-
ducteur de terre de l’équipement avec des conducteurs en cuivre de cali-
bre minimal de 8 AWG US / 6 AWG Canada.
AVIS À L’UTILISATEUR: Ce produit antiparasitaire doit être employé
strictement selon le mode d’emploi d’un tel produit dans des conditions
dangereuse constitue une infraction à la Loi sur les produits antipara-
sitaires.
CONSERVEZ CES INSTRUCTIONS
UTILISEZ UNIQUEMENT DES PIÈCES DE REMPLACEMENT D’ORIGINE HAYWARD
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
1
Introduction
L’Aqua Trol est un générateur de chlore automatique pour piscines hors-terre. Pour fonctionner, le chlorateur
requiert une faible concentration de sel (chlorure de sodium) dans l’eau de la piscine. La concentration de sel
requise est si faible que normalement l’eau ne devrait pas goûter salée. Le système Aqua Trol désinfecte au-
tomatiquement votre piscine en transformant le sel en chlore libre qui tue les bactéries et les algues. Le chlore
revient à l’état de chlorure de sodium après avoir tué les bactéries. Ces réactions se recyclent continuellement,
ce qui permet d’éliminer pratiquement tout besoin d’agents d’assainissement dans votre piscine. La seule fois
où vous aurez à ajouter du sel dans la piscine est lors du remplissage pour compenser une perte d’eau suite à
un lavage à contre-courant, à un drainage ou à de gros éclaboussements (et non de l’évaporation).
Conçu pour répondre aux besoins de purification de piscine hors terre résidentielle d’une capacité maximale de
67 500 litres (18 000 gallons), le système Aqua Trol produit la quantité nécessaire de chlore pour permettre la
désinfection appropriée de l’eau en fonction du nombre de baigneurs, des précipitations et de la propreté de
la piscine.
NOTE : Avant de procéder à l’installation de ce produit dans le système de purification d’eau saline d’une piscine
hors terre dont la terrasse ou le patio adjacent est fait de pierres naturelles, consulter un spécialiste qualifié
en installation de produits de pierres naturelles en ce qui a trait au type, à l’installation, à l’étanchéisation (s’il
y a lieu) et à l’entretien des pierres posées autour d’une piscine à eau saline dotée d’un générateur de chlore
électronique selon l’endroit ou les circonstances où la piscine est installée.
NOTE : L’utilisation d’acide sec (bisulfate de sodium) pour ajuster le pH de la piscine est déconseillée particu-
lièrement dans des régions arides où l’eau de piscine est sujette à une évaporation excessive et n’est pas
généralement diluée avec un ajout d’eau. L’acide sec peut endommager la cellule de votre chlorateur.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
UTILISEZ UNIQUEMENT DES PIÈCES DE REMPLACEMENT D’ORIGINE HAYWARD
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
2
Composition chimique de l’eau
Le tableau ci-dessous récapitule les concentrations recommandées par le The Association of Pool and Spa
Professionals (APSP). Les seules exigences spéciales du système Aqua Trol sont les concentrations de sel et
de stabilisant. Il est important de maintenir les concentrations recommandées afin de prévenir la corrosion ou
l’écaillage des surfaces et assurer la jouissance maximale de la piscine. Testez votre eau régulièrement. Votre
distributeur agréé Aqua Trol ou la plupart des vendeurs de piscines vous fourniront des produits chimiques avec
leur mode d’emploi pour ajuster la composition chimique de l’eau de votre piscine. N’oubliez pas de mentionner
au fournisseur que vous utilisez un chlorateur Aqua Trol.
Indice de saturation
L’indice de saturation (Si) nous renseigne sur la teneur en calcium et le degré d’alcalinité de l’eau; cet indice est
un indicateur de « l’équilibre » de l’eau. Votre eau est convenablement équilibrée si le Si est de 0 ±0,2. Si le Si
est inférieur à -0,2, l’eau est corrosive et le plâtre des parois de la piscine est susceptible d’être attaqué et de
se dissoudre dans l’eau. Si le Si est supérieur à +0,2, de l’écaillage et de la coloration se produiront. Utilisez le
tableau ci-dessous pour déterminer l’indice de saturation.
Si = pH + Ti + Ci + Ai - TDS
Dureté
75
100
125
150
200
250
300
400
600
800
Matiéres Totales
Dissoutes
L’alcalinité
Totale
°C °F Ti Ci Ai TDS
12
16
19
24
29
34
39
53
60
66
76
84
94
102
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.5
1.6
1.7
1.8
1.9
2.0
2.1
2.2
2.4
2.5
75
100
125
150
200
250
300
400
600
800
1.9
2.0
2.1
2.2
2.3
2.4
2.5
2.6
2.8
2.9
0-1000
1001-2000
2001-3000
3001-4000
4001-5000
12.10
12.29
12.35
12.41
12.44
Pour utiliser : Mesurez le pH, la température, la dureté, l’alcalinité totale et les matières
totales dissoutes (TDS) de l’eau de la piscine. Consultez le tableau ci-dessus pour
déterminer les valeurs de Ti, Ci, Ai et TDS dans l’équation précédente. Si Si est égal ou
supérieur à 0,2, des taches pourraient apparaître. Si Si est égal ou inférieur à -0,2, il
pourrait y avoir de la corrosion ou de la détérioration.
Corrosion Des Taches
Ok
-0.2 0.2
PRODUITS CHIMIQUES NIVEAUX IDÉAUX
Sel Mode Salinité normale — 2700 à 3400ppm
Mode Salinité faible — 1200 à 1800ppm
Chlore libre 1,0 à 3,0ppm
pH 7,2 à 7,6
Acide cyanurique
(Stabilisateur) 20 à 30ppm (si nécessaire)
Alcalinité totale 80 à 120ppm
Dureté calcique 125 à 250ppm
Métaux 0ppm
Indice de saturation Meilleur de -0,2 à 2,0
UTILISEZ UNIQUEMENT DES PIÈCES DE REMPLACEMENT D’ORIGINE HAYWARD
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Hayward aqua trol Le manuel du propriétaire

Catégorie
Accessoires de piscine hors terre
Taper
Le manuel du propriétaire

dans d''autres langues