Hayward H150FDP Le manuel du propriétaire

Catégorie
Outils de jardin
Taper
Le manuel du propriétaire
FOR YOUR SAFETY
WARNING: If the information in these
instructions is not followed exactly, a re or
explosion may result causing property damage,
injury, or death.
- Donotstoreorusegasolineorotheram-
mablevaporsorliquidsinthevicinityofthis
oranyotherappliance.
WHAT TO DO IF YOU SMELL GAS:
• Donottrytolightanyappliance.
• Donottouchanyelectricalswitch;donotuse
anyphoneinyourbuilding.
• Immediatelycallyourgassupplierfroma
neighborsphone.Followthegassuppliers
instructions.
• Ifyoucannotreachyourgassupplier,callthe
redepartment.
-Installationandservicemustbeperformedby
aqualiedinstaller,serviceagency,orthegas
supplier.
POOL AND SPA/HOT TUB HEATERS
H150FD, H200FD, H250FD, H300FD,
H350FD, H400FD & H500FD MODELS
OWNER’S MANUAL
FOR YOUR SAFETY
Thisproductmustbeinstalledandservicedbyauthorizedpersonnel,qualiedinpool/spa
heaterinstallation.Improperinstallationand/oroperationcancreatecarbonmonoxidegas
anduegasesthatcancauseseriousinjury,propertydamage,ordeath.
1301640701 REV G 0914
PRINTED 10/24/2011 AT 1:13 PM
U.S. PATENT NOS. 6,321,833 & 7,971,603
Pomona, CA Clemmons, NC Nashville, TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
2
Warnings .......................................................................................................3
Section I. General information .......................................................................7
Section II. Consumer Operation & Maintenance ...........................................8
Maintaining proper water chemistry...............................................................8
Lighting & Operating instructions label ........................................................10
Temperature adjustment ..............................................................................11
Temperature Lock-out..................................................................................12
Fahrenheit versus Celsius ...........................................................................12
Winterization ................................................................................................12
Spring start-up .............................................................................................12
Error codes ..................................................................................................13
Warranty ......................................................................................................15
CONTENTS
Pomona, CA Clemmons, NC Nashville, TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
3
Basicsafetyprecautionsshouldalwaysbefollowed,includingthefollowing:Failuretofollowinstructions
cancausesevereinjuryand/ordeath.
Thisisthesafety-alertsymbol.Whenyouseethissymbolonyourequipmentorinthismanual,lookfor
oneofthefollowingsignalwordsandbealerttothepotentialforpersonalinjury.
WARNINGwarnsabouthazardsthatcouldcauseseriouspersonalinjury,deathormajorpropertydam-
ageandifignoredpresentsapotentialhazard.
CAUTIONwarnsabouthazardsthatwillorcancauseminorormoderatepersonalinjuryand/orprop-
ertydamageandifignoredpresentsapotentialhazard.Itcanalsomakeconsumersawareofactionsthat
areunpredictableandunsafe.
ATTENTIONindicatesspecialinstructionsthatareimportantbutnotrelatedtohazards.
READ AND FOLLOW ALL INSTRUCTIONS IN THIS OWNER’S
MANUAL AND ON EQUIPMENT.
IMPORTANT SAFETY INSTRUCTIONS
Before installing or servicing this electrical equipment, turn power supply OFF.
KEEP SAFETY LABELS IN GOOD CONDITION AND REPLACE IF MISSING OR DAMAGED.
WARNING–Toreduceriskofinjury,donotpermitchildrentouseorclimbontheheater,pumpsor
lters.Closelysupervisechildrenatalltimes.Componentssuchastheltrationsystem,pumps,and
heatersmustbepositionedtopreventchildrenfromusingthemasameansofaccesstothepool.
CAUTION –Thisheaterisintendedforuseonpermanentlyinstalledswimmingpoolsandmayalso
beusedwithspas.DoNOTusewithstorablepools.Apermanentlyinstalledpoolisconstructedinor
onthegroundorinabuildingsuchthatitcannotbereadilydisassembledforstorage.Astorablepoolis
constructedsothatitiscapableofbeingreadilydisassembledforstorageandreassembledtoitsoriginal
integrity.
Thoughthisproductisdesignedforoutdooruse,itisstronglyrecommendedtoprotecttheelectrical
componentsfromtheweather.Selectawelldrainedarea,onethatwillnotoodwhenitrains.Itrequiresfree
circulationofairforcooling.Donotinstallinadampornon-ventilatedlocation.
WARNING –Itisrequiredthatlicensedelectriciansdoallelectricalwiring.Riskof
ElectricShock.Hazardousvoltagecanshock,burn,causedeathorseriousproperty
damage.Toreducetheriskofelectricshock,doNOTuseanextensioncordtoconnect
unittoelectricsupply.Provideaproperlylocatedoutlet.AllelectricalwiringMUSTbe
inconformancewithapplicablelocalandnationalcodesandregulations.Beforework-
ingonthisunit,turnoffpowersupplytotheheater.
WARNING –Toreducetheriskofelectricshockreplacedamagedwiringimmediately.Locateconduit
topreventabusefromlawnmowers,hedgetrimmersandotherequipment.
WARNING –Failuretobondtopoolstructurewillincreaseriskforelectrocutionandcouldresultin
injuryordeath.Toreducetheriskofelectricshock,theelectricianmustcomplywithinstallationin-
structionsandmustbondtheheateraccordingly.Inaddition,thelicensedelectricianmustalsoconform
tolocalelectricalcodesforbondingrequirements.
SAFETY INFORMATION
Pomona, CA Clemmons, NC Nashville, TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
4
NOTES TO THE ELECTRICIAN:
Useasolidcopperconductor,size8orlarger.Runacontinuouswirefromexternalbondinglugtorein-
forcingrodormesh.ConnectaNo.8AWGsolidcopperbondingwiretothegroundinglugprovidedonthe
heaterandtoallmetalpartsofswimmingpoolorspa,andtoallelectricalequipment,metalpiping(except
gaspiping),andconduitwithin5ft.(1.5m)ofinsidewallsofswimmingpoolorspa.
IMPORTANT-ReferenceNECcodesforallwiringstandardsincluding,butnotlimitedto,grounding,
bondingandothergeneralwiringprocedures.
WARNING Suction Entrapment Hazard.
Suctioninsuctionoutletsand/orsuctionoutletcoverswhicharedamaged,broken,
cracked,missing,orunsecuredcancausesevereinjuryand/ordeathduetothefol-
lowingentrapmenthazards:
Hair Entrapment-Haircanbecomeentangledinsuctionoutlets.
Limb Entrapment-Alimbinsertedintoanopeningofasuctionoutletorsuctionoutlet
coverthatisdamaged,broken,cracked,missing,ornotsecurelyattachedcanresultina
mechanicalbindorswellingofthelimb.
Body Suction Entrapment-Adifferentialpressureappliedtoalargeportionofthebodyorlimbscan
resultinanentrapment.
Evisceration/ Disembowelment-Avacuumapplieddirectlytotheintestinesthroughanunprotected
suctionoutletsumporsuctionoutletcoverwhichisdamaged,broken,cracked,missing,orunsecured
canresultinevisceration(disembowelment).
Mechanical Entrapment-Thereispotentialforjewelry,swimsuit,hairdecorations,nger,toeorknuck-
letobecaughtinanopeningofasuctionoutletorsuctionoutletcoverresultinginmechanicalentrap-
ment.
WARNING-Toreducetheriskofentrapmenthazards:
• Whensuctionoutletsarelessthana18”x23”equivalent,aminimumoftwofunction-
ingsuctionoutletsperpumpmustbeinstalled.Suctionoutletsinthesameplane(i.e.
oororwall),mustbeinstalledaminimumofthreefeet(3’)[1meter]apart,asmea-
suredfromnearpointtonearpoint.
• Dualsuctionoutletsshallbeplacedinsuchlocationsanddistancestoavoid“dual
blockage”byauser.
• Dualsuctionttingsshallnotbelocatedonseatingareasoronthebackrestforsuch
seatingareas.
• Themaximumsystemowrateshallnotexceedtheowratingofanylisted(percurrentrevisionof
ASME/ANSIA112.19.8)suctionoutletcoverinstalled.
• NeverusethePoolorSpaifanysuctionoutletcomponentisdamaged,broken,cracked,missing,or
notsecurelyattached.
• Replacedamaged,broken,cracked,missing,ornotsecurelyattachedsuctionoutletcomponentsim-
mediately.
• InstalltwoormoresuctionoutletsperpumpinaccordancewithlatestAPSP(formallyNSPI)Stan-
dardsandCPSCguidelines.FollowallapplicableNational,State,andLocalcodes.
Pomona, CA Clemmons, NC Nashville, TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
5
WARNING–Failuretoremovepressuretestplugsand/orplugsusedinwinterizationofthepool/spa
fromthesuctionoutletscanresultinanincreasepotentialforsuctionentrapmentasdescribedabove.
WARNING–Failuretokeepsuctionoutletcomponentsclearofdebris,suchasleaves,dirt,hair,paper
andothermaterialcanresultinanincreasepotentialforsuctionentrapmentasdescribedabove.
WARNING–Suctionoutletcomponentshaveanitelife,thecover/grateshouldbeinspectedfre-
quentlyandreplacedatleasteverytenyearsoriffoundtobedamaged,broken,cracked,missing,ornot
securelyattached.
WARNING–AllsuctionanddischargevalvesMUSTbeOPENwhenstartingthecirculationsystem.
Failuretodosocouldresultinseverepersonalinjuryand/orpropertydamage.Alldrainsandsuction
outletsMUSThaveproperlyinstalledcovers,securelyattachedusingthescrewssuppliedwiththecov-
ers.Ifscrewsarelost,orderreplacementpartsfromyoursupplier.
WARNING Hazardous Pressure.Poolandspawatercirculationsystemsoperate
underhazardouspressureduringstartup,normaloperation,andafterpumpshutoff.
Standclearofcirculationsystemequipmentduringstartup.Failuretofollowsafety
andoperationinstructionscouldresultinviolentseparationofthepumphousing
andcoverduetopressureinthesystem,whichcouldcausepropertydamage,severe
personalinjury,ordeath.Beforeservicingpoolandspawatercirculationsystem,all
systemandpumpcontrolsmustbeinoffpositionandltermanualairreliefvalve
mustbeinopenposition.Beforestartingsystempump,allsystemvalvesmustbeset
inapositiontoallowsystemwatertoreturnbacktothepool.Donotchangelter
controlvalvepositionwhilesystempumpisrunning.Beforestartingsystempump,
fullyopenltermanualairreliefvalve.Donotcloseltermanualairreliefvalve
untilasteadystreamofwater(notairorairandwater)isdischarged.
WARNINGSeparation Hazard.Failuretofollowsafetyandoperationinstruc-
tionscouldresultinviolentseparationofpumpcomponents.Strainercovermustbe
properlysecuredtopumphousingwithstrainercoverlockring.Beforeservicing
poolandspacirculationsystem,manualairreliefvalvemustbeinopenposition.Do
notoperatepoolandspacirculationsystemifasystemcomponentisnotassembled
properly,damaged,ormissing.Donotoperatepoolandspacirculationsystemunless
lterairreliefvalvebodyisinlockedpositioninlterupperbody.
WARNING –Neveroperateortestthecirculationsystematmorethan40PSI.
WARNING–Fireandburnhazard.Motorsoperateathightemperaturesandiftheyarenotproperly
isolatedfromanyammablestructuresorforeigndebristheycancauseres,whichmaycausesevere
personalinjuryordeath.Itisalsonecessarytoallowthemotortocoolforatleast20minutespriorto
maintenancetominimizetheriskofburns.
WARNING–Failuretoinstallaccordingtodenedinstructionsmayresultinseverepersonalinjuryor
death.
Pomona, CA Clemmons, NC Nashville, TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
6
WARNING–Thefollowing“SafetyRulesforHotTubs”recommendedbytheU.S.Consumer
ProductSafetyCommissionshouldbeobservedwhenusingthespa.
1. Spaorhottubwatertemperaturesshouldneverexceed104°F[40°C].Atemperatureof100°F
[38°C]isconsideredsafeforahealthyadult.Specialcautionissuggestedforyoungchildren.Pro-
longedimmersioninhotwatercaninducehyperthermia.
2. Drinkingofalcoholicbeveragesbeforeorduringspaorhottubusecancausedrowsiness,which
couldleadtounconsciousnessandsubsequentlyresultindrowning.
3. Pregnantwomenbeware!Soakinginwaterabove100°F[38°C]cancausefetaldamageduringthe
rstthreemonthsofpregnancy(resultinginthebirthofabrain-damagedordeformedchild).Preg-
nantwomenshouldadheretothe100°F[38°C]maximumrule.
4. Beforeenteringthespaorhottub,usersshouldcheckthewatertemperaturewithanaccuratether-
mometer;spaorhottubthermostatsmayerrinregulatingwatertemperaturesbyasmuchas4°F
(2.2°C).
5. Personstakingmedications,whichinducedrowsiness,suchastranquilizers,antihistaminesoranti-
coagulants,shouldnotusespasorhottubs.
6. Ifthepool/spaisusedfortherapy,itshouldbedonewiththeadviceofaphysician.Alwaysstirpool/
spawaterbeforeenteringthepool/spatomixinanyhotsurfacelayerofwaterthatmightexceed
healthfultemperaturelimitsandcauseinjury.Donottamperwithcontrols,becausescaldingcan
resultifsafetycontrolsarenotinproperworkingorder.
7. Personswithamedicalhistoryofheartdisease,circulatoryproblems,diabetesorbloodpressure
problemsshouldobtainaphysiciansadvicebeforeusingspasorhottubs.
8. Hyperthermiaoccurswhentheinternaltemperatureofthebodyreachesalevelseveraldegrees
abovenormalbodytemperatureof98.6°F[37°C].ThesymptomsofHyperthermiainclude:drowsi-
ness,lethargy,dizziness,fainting,andanincreaseintheinternaltemperatureofthebody.
The effects of Hyperthermia include:
1. Unawarenessofimpendingdanger.
2. Failuretoperceiveheat.
3. Failuretorecognizetheneedtoleavethespa.
4. Physicalinabilitytoexitthespa.
5. Fetaldamageinpregnantwomen.
6. Unconsciousnessresultingindangerofdrowning.
DEFINITIONS:
SuctionOutlet– ThetermSuctionOutletisatting,ttingassembly,cover/grateandrelatedcompo-
nentsthatprovideameansforwatertoexitthepoolandintothepumpcirculating
system.
Inchesof
Mercury(inHg)- Aunitformeasuringpressurebelowatmospheric(“suction”or“vacuum”)(1.0inch
Hg=.491PSI)
MainDrain– SeeSuctionOutlet
PSI– Anabbreviationforpoundspersquareinch.
Pomona, CA Clemmons, NC Nashville, TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
7
INTRODUCTION:
Thismanualcontainsinstructionsforoperationandthesafeuseoftheswimmingpool/spa/hottubheat-
ers.Haywardstronglyrecommendsthattheownerreadthemanualbeforeusingtheswimmingpool/spa/
hottubheater.Ifafterreviewingthemanualanyquestionsremainunanswered,contactthefactoryorlocal
representative.
LIMITED WARRANTY SUMMARY:
Wewarrantthepool/spa/hottubheatertobefreefromdefectsinmaterialsandworkmanship,andwe
willwithinoneyearfromdateofinstallationforallusers,fortheoriginalpurchaser,repairor,atouroption,
replacewithoutchargeanydefectivepart.Wefurtherwarrantthatiftheheatexchangerorexchangerheaders
(water-containingsection)leakwithinoneyearfromdateofsuchinstallationforallusers,duetodefectsin
materialsandworkmanship,wewillprovideareplacementpart.Costoffreight,installation,fuel,andservice
labor(afteroneyear)isatusersexpense.Forfulldetailsofwarrantyagreement,seewarrantycerticate
includedinthismanual.
ATTENTION:Ifthepool/spa/hottubheaterisdamagedordestroyedbyimpropermaintenance,exces-
sivewaterhardness,incorrectwaterchemistry,orfreezingitisnotcoveredunderthemanufacturers
warranty.
SECTION I. GENERAL INFORMATION
Pomona, CA Clemmons, NC Nashville, TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
8
SECTION II. CONSUMER OPERATION & MAINTENANCE
TheheatexchangerinyourHaywardpoolheaterismadefromthehighestqualityofcopperandnickel
(Cupronickel)materials.Thepremiummaterialsandtheexactingprocessesusedinthemanufactureofthe
heatexchangerisstateoftheartinpoolheaterdesignandmanufacture.Yet,itremainsvitalthattheheatex-
changerbeprotectedfromdamagingorcorrosivechemicals,insufcientwateroworimproperlybalanced
waterchemistry.Heatexchangerdamageorfailureresultingfromimproperow,improperlybalancedpool
waterortheimproperadditionofsanitizersintothewaterisNOTcoveredunderthetermsofyourwarranty.
Thefollowingfactorsarecriticaltoheatexchangerprotection.Followtheseguidelinestohelpprevent
pre-maturedamageorfailuretoyourheaterandheatexchanger.
1. WATER FLOW THROUGH HEATER
Watermustbeowingthroughtheheaterattheminimumratedowrateduringoperation.Checkthat
thepumpisoperatingandthesystemislledwithwaterandpurgedofallairpriortostartingtheheater.The
minimumratedowratesarelistedintheinstallationmanualonpage26.Someinstallationsmayrequirean
adjustmenttothewaterpressureswitchforproperlow-owprotection.Testyoursystemandifnecessary,
adjustthewaterpressureswitchasdescribedintheinstallationmanualonpage36.
2. POOL/SPA WATER CHEMISTRY
Thechemistrybalanceandmineralcontentofswimmingpoolwaterchangesdailyduetotheadditionof
poolandsanitizingchemicals,batherloads,rain,runoffandtheamountofsun-tonameafew.Improperchem-
istrybalanceandmineralcontentcancausescalinganddepositstoformonpoolwalls,intheltrationsystem,
intheheatexchangertubesandadditionallycanpromotecorrosiveactiontoallmetalsinthewaterpath.Chang-
ingspawaterregularlyandmaintainingthecorrectchemicalbalanceinyourpool/spawillkeepthepool/spa
safeandsanitary,andwillhelpprotecttheheatexchanger.Usea4-waypool/spawatertestkittocheckyour
waterfrequently(atleastweekly).Usethefollowingguidelinestohelpprotectyourheatersheatexchanger:
3. SKIMMER CHLORINATION
Placingchlorineorbrominetabletsdirectlyintotheskimmermayresultinhighchemicalconcentrations
owingthroughtheheater.DONOTplacechlorineorbrominetabletsintheskimmer.
WARNING:
Failure to Maintain Proper Water Chemistry May Cause
Premature Heat Exchanger Damage or Failure
MAINTAINING PROPER WATER CHEMISTRY
Recommended
Level
Effect of Low Levels Effect of High Levels
Chlorine
1 - 3 ppm
Bromine
2 - 4 ppm
pH
7.4 - 7.6
corrosive to heat exchanger,
swimmer irritation
cloudy water, scaling of heat exchanger,
reduced sanitizer effectiveness
Total Alkalinity
80 - 120 ppm
corrosive to heat exchanger,
large fluctuations in pH
scaling of heat exchanger
Calcium Hardness
200 - 400 ppm corrosive to heat exchangerscaling of heat exchanger
Salt
2700 - 5000 ppm poor salt chlorinator performancecorrosive to heat exchanger
hazy water, algea growth,
bacteria causing infections
swimmer irritation, bleaching of clothes/hair,
corrosive to heat exchanger
Pomona, CA Clemmons, NC Nashville, TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
9
New Figure 1 for UHS owner manual page 9:
Figure 1
New text for UHS owner manual page 11:
TEMPERATURE ADJUSTMENT
This pool heater is equipped with a digital thermostat which allows the user to select the desired
water temperature. The heater will then function automatically to maintain the desired
temperature. The heater has 3 modes of operation:
1. STANDBY: in this mode, the heater will not function to heat the water.
2. SPA: in this mode, the heater will automatically function to maintain the water
temperature setting for SPA mode.
3. POOL: in this mode, the heater will automatically function to maintain the water
temperature setting for POOL mode.
Use the MODE button to change modes. The indicator lights will illuminate to show which mode
the heater is currently in. Each mode has its own temperature setting, allowing the user to have
2 individual pre-set temperature settings. To adjust the temperature while in SPA or POOL
mode, use the UP and DOWN buttons. The numeric display will flash to indicate the
temperature setting is being displayed / adjusted. When the numeric display is not flashing, the
actual water temperature is being displayed. The temperature settings for both SPA and POOL
modes are initially set at the factory to 65°F. The minimum allowed settings for SPA and POOL
modes are both 65°F. The maximum allowed settings for SPA and POOL modes are adjustable
up to 104°F using the temperature lockout feature (see below).
After selecting SPA or POOL mode or adjusting the temperature setting, it is normal for the
heater to delay up to 10 seconds before the heater starts operating. This delay is an internal
self-test of the heater. On occasion, the numeric display may show a diagnostic error code;
refer to list of diagnostic error codes in Figure 4. Pressing the MODE button to cycle to
STANDBY and back to SPA or POOL will clear a diagnostic error code. When clearing a
User Interface
Keypad
Front Access
Panel
WARNING:Ifyousmellgasintheapplianceareaorneartheoor(PROPANEIS
HEAVIERTHANAIRANDHENCESETTLESONTHEFLOOR),stopandfollow
theinstructionsonthefrontcoverofthismanual.Sincepropanecanaccumulateincon-
nedareas,extracareshouldbetakenwhenlightingpropaneheaters.
ATTENTION:Donotusetheheaterbelow40°F(4°C)temperaturewithoutadequatetemperatureprotection.
WARNING:Donotingestalcoholordrugsduringuseorpriortousingpool,spa,orhottub.Ingestionofsuch
intoxicantscancausedrowsiness,whichcanleadtounconsciousness,andsubsequentlyresultindrowning.
4. CHLORINATOR INSTALLATION
Chlorinatorsmustbeinstalleddownstreamoftheheater,andacheckvalvemustbeinstalledbetweenthe
heaterandchlorinatortopreventhighchemicalconcentrationsfrombackowingintotheheater.Makesureyour
pipingarrangementmeetsthechlorinatorinstallationrequirementsshownintheinstallationmanualonpage26.
5. BYPASS
Untilwaterchemistryisproperlybalanced,andifyourpipinghasabypassvalveinstalledfortheheater,
openthebypasssothatcorrosiveandpotentiallydamagingwaterwillnotowthroughtheheaterandthere-
foretheheatexchanger.Closethebypassvalveoncethewaterisproperlybalanced.Failuretoclosethe
bypassvalvewhenattemptingtooperatetheheaterwillresultinextensivedamagetotheheatexchanger.
Ensurewaterowthroughtheheaterisrestoredbeforeoperatingtheheater.Abypassfeatureisalsoadvanta-
geousforserviceneedsandfortheabilitytoremovetheheaterfromthewaterpathwhennotheating.Refer
topage26intheinstallationmanualforfurtherinformation.
HEATER OPERATION:
Fulllightingandshutdowninstructionsareincludedonthelighting&operatinginstructionslabelafxed
totheinsideofthefrontaccesspanel.SeeFigure1forthelocationofthislabelandthekeypad.SeeFigure2
forthelabel.
Figure1:Keypadandlabellocations
Pomona, CA Clemmons, NC Nashville, TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
10
Figure2:Lighting&OperatingInstructionslabel
Pomona, CA Clemmons, NC Nashville, TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
11
TEMPERATURE ADJUSTMENT
Thispoolheaterisequippedwithadigitalthermostatwhichallowstheusertoselectthedesiredwater
temperature.Theheaterwillthenfunctionautomaticallytomaintainthedesiredtemperature.Theheaterhas
3modesofoperation:
1. STANDBY:inthismode,theheaterwillnotfunctiontoheatthewater.
2. SPA:inthismode,theheaterwillautomaticallyfunctiontomaintainthewatertemperaturesettingfor
SPAmode.
3. POOL:inthismode,theheaterwillautomaticallyfunctiontomaintainthewatertemperaturesetting
forPOOLmode.
UsetheMODEbuttontochangemodes.Theindicatorlightswillilluminatetoshowwhichmodethe
heateriscurrentlyin.Eachmodehasitsowntemperaturesetting,allowingtheusertohave2individual
pre-settemperaturesettings.ToadjustthetemperaturewhileinSPAorPOOLmode,usetheUPandDOWN
buttons.Thenumericdisplaywillashtoindicatethetemperaturesettingisbeingdisplayed/adjusted.When
thenumericdisplayisnotashing,theactualwatertemperatureisbeingdisplayed.Thetemperaturesettings
forbothSPAandPOOLmodesareinitiallysetatthefactoryto65°F.TheminimumallowedsettingsforSPA
andPOOLmodesareboth65°F.ThemaximumallowedsettingsforSPAandPOOLmodesareadjustableup
to104°Fusingthetemperaturelockoutfeature(seenextsection).
AfterselectingSPAorPOOLmodeoradjustingthetemperaturesetting,itisnormalfortheheaterto
delayupto10secondsbeforetheheaterstartsoperating.Thisdelayisaninternalself-testoftheheater.On
occasion,thenumericdisplaymayshowadiagnosticerrorcode;refertolistofdiagnosticerrorcodesin
Figure4.PressingtheMODEbuttontocycletoSTANDBYandbacktoSPAorPOOLwillclearadiagnostic
errorcode.Whenclearingadiagnosticerrorcodethisway,itisnormalfortheheatertodelayupto5seconds
beforeresumingnormaloperation,assumingthediagnosticerrorcodedoesnotre-appear.
diagnostic error code this way, it is normal for the heater to delay up to 5 seconds before
resuming normal operation, assuming the diagnostic error code does not re-appear.
Figure 3: User interface keypad
TEMPERATURE LOCK-OUT
The digital thermostat in this pool heater allows the user to lock the maximum temperature
setting allowed. This feature is useful for preventing unauthorized users from manually adjusting
the temperature settings higher than desired. On a new heater, the maximum allowed
temperature lock settings are initially set at the factory to 90°F for POOL mode, and 104°F for
SPA mode. To adjust these settings, use the following procedure:
1. Use the MODE button to put the heater in STANDBY mode.
2. Press and hold both the UP and DOWN buttons at the same time.
3. After 3 seconds, the thermostat enters maximum temperature lock adjustment mode.
4. The SPA indicator light illuminates and the numeric display shows the current SPA mode
maximum temperature lock setting. Both the SPA indicator light and the numeric display
flashes rapidly when in adjustment mode.
5. Use the UP and DOWN buttons to set the desired maximum temperature lock setting.
When finished, press the MODE button.
6. The POOL indicator light illuminates and the numeric display shows the current POOL
mode maximum temperature lock setting. Both the POOL indicator light and the
numeric display flashes rapidly when in adjustment mode.
7. Use the UP and DOWN buttons to set the desired maximum temperature lock. When
finished, press the MODE button.
8. The heater will return to STANDBY mode.
Numeric Display
Buttons
Indicator Lights
Figure3:Userinterfacekeypad
12
TEMPERATURE LOCK-OUT:
Thedigitalthermostatinthispoolheaterallowstheusertolockthemaximumtemperaturesettingallowed.
Thisfeatureisusefulforpreventingunauthorizedusersfrommanuallyadjustingthetemperaturesettingshigher
thandesired.Onanewheater,themaximumallowedtemperaturelocksettingsareinitiallysetatthefactoryto
90°FforPOOLmode,and104°FforSPAmode.Toadjustthesesettings,usethefollowingprocedure:
1. UsetheMODEbuttontoputtheheaterinSTANDBYmode.
2. PressandholdboththeUPandDOWNbuttonsatthesametime.
3. After3seconds,thethermostatentersmaximumtemperaturelockadjustmentmode.
4. TheSPAindicatorlightilluminatesandthenumericdisplayshowsthecurrentSPAmodemaximum
temperaturelocksetting.BoththeSPAindicatorlightandthenumericdisplayashesrapidlywhenin
adjustmentmode.
5. UsetheUPandDOWNbuttonstosetthedesiredmaximumtemperaturelocksetting.Whennished,
presstheMODEbutton.
6. ThePOOLindicatorlightilluminatesandthenumericdisplayshowsthecurrentPOOLmodemaximum
temperaturelocksetting.BoththePOOLindicatorlightandthenumericdisplayashesrapidlywhenin
adjustmentmode.
7. UsetheUPandDOWNbuttonstosetthedesiredmaximumtemperaturelock.Whennished,pressthe
MODEbutton.
8. TheheaterwillreturntoSTANDBYmode.
FAHRENHEIT VERSUS CELSIUS:
ThetemperaturecanbedisplayedinFahrenheitorCelsius.TOchangethedisplay,usethe“MODE”button
toplacetheheaterin“STANDBY”.Thenpressandholdthe“UP”and“MODE”buttonsuntilthedisplayshows
the°F/°Cselection.Pressthe“DOWN”buttontotogglebetweenselections.Toaccepttheselection,pressthe
“MODE”button.Iftheuserdoesnotact,theselectionwillbeautomaticallyacceptedafter60seconds.
WINTERIZATION:
Inmoderateclimates,theheatercancontinuetooperateduringshort-termcoldspells.Donotusethe
heatertomaintainthewatertemperaturejustabovefreezingorforfreezeprotection.Caremustbetakento
avoidfreeze-upintheheater.Whenitisusedduringfreezingweather,thepumpmustruncontinuously.The
heaterisnotwarrantedagainstfreeze-ups.Inregionswherefreezingtemperaturesareencountered,allwater
mustbedrainedfromtheheaterwhenitisoutofservice,topreventdamagetotheheaterandpiping.Drain-
ingtheheatexchangerisrecommendedaspartoftheseason’sshutdownprocedures.
SPRING START-UP CONSULT A PROFESSIONAL:
1. Inspectandcleantheheater,beingsuretheheaterisfreeofleavesanddebrispriortostartup.
2. Besureinletandoutletpipingareproperlyattachedtotheheaterandthedrainvalveisclosed.
3. Turntheltrationsystempump“ON”andallowthesystemtorunlongenoughtopurgealltheair
fromthelines.
4. Turnthegassupplytotheheater“ON”.
5. Setthetemperaturecontrolusingthekeypadto“POOL”or“SPA”andadjustthesetpointtothe
desiredtemperaturesetting.
6. Ifoperatingdifcultiesareencountered,contactaqualiedservicecompanyforassistance.
Pomona, CA Clemmons, NC Nashville, TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
13
Figure4:ERROR CODES
ERROR CODES:
Figure4liststheerrorcodesthatmaybedisplayedontheheaterdisplayboard.
Contactaqualiedservicecompanyforassistance.
Code Description Information
bD
Internalfault/power-up
error
Oninitialtrialforignition.Automaticresetisimmediateoncethegasvalverelay
checkresultsareacceptable.
bD
Gasvalvesensed
as“ON”error
Ifvalveisopenwhenitshouldbeclosedtheheaterwillshutdownandgointo
lockout.Blowerwilloperateuntilerrorconditioniscorrected.Automaticrestart
2minutesaftererroriscorrected.
bD
Gasvalvesensed
as“OFF”error
Ifvalveisclosedbutameissensedtheblowerwillrunfor5sthenstartanew
ignitionsequence.Iferroroccurs10timesduringacallforheatthecontrolwill
gointolockout.Automaticresetis60minutes.
bD Dataretrievalerror Ifcontrolinputdataiscorruptedtheheaterwillshutdownandgointolockout.
HF
Flamepresentwithgas
valve“OFF”error
Ifameissensedwiththegasvalveoffthecontrolwillgointolockout.The
blowerwillrununtilerrorconditioniscorrected.Whencorrected,controlwill
runblowerfor5sthenautomaticallyrestartafter2minutes.
PF
Electricalsupplywiring
error
Thiscodewilldisplayif120Vpolarityisreversed,lowvoltageisdetected,orif
thegroundpathisnotsufcient.Resetisimmediateaftererroriscorrected.
AO
Blowervacuumswitch
openerror
Iftheblowerproverswitchdoesnotcloseaftertheblowerstartsthecontrolwill
stoptheignitiontrialgointolockout.Theblowerwillcontinuetorun.Automatic
resetisimmediateaftertheswitchcloses.
AO
Blowervacuumswitch
openwhenexpected
closederror
Iftheblowerproverswitchopensunexpectedlyduringoperationthecontrolwill
shutdownandattempttore-light.Iftheswitchdoesnotcloseaftertheblower
startsthecontrolwillgointolockoutwiththeblowerrunning.Automaticresetis
immediateaftererroriscorrected.
AO
Blowervacuumswitch
openduringpost-purge
error
Iftheblowerproverswitchopensduringthepostpurgecycle(heaterisnotr-
ing)thecontrolwilldisplaytheerrorcode.Thepost-purgecyclewillbecom-
pletedoncetheblowerproverswitchcloses.
AC
Blowervacuumswitch
closedwhenexpected
openerror
Iftheblowerproverswitchisclosedbeforeblowerstart-upthecontrolwillnot
starttheblower.Automaticresetisimmediatewhentheswitchopens.
Pomona, CA Clemmons, NC Nashville, TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
14
Figure4:ERROR CODES(continued)
Code Description Information
IO
Igniteropenerror Ifthecontrolisnotinlockoutandsensesthattheignitercircuitisopenwhenthe
blowerisrunningthecontrolwillturnofftheblowerandgointolockout.Auto-
maticrestart2minaftererroriscorrected.
SF
Thermistorerror Anexcessivetemperaturedifferencebetweenthetwothermistors(5°Formore)
oran“outofbounds”conditiononbothsensors(lessthan10°Forgreaterthan
180°F)willresultintheerrorcode.Automaticrestartis2minutesaftertheerror
iscorrected.
HS
WaterTemperature
SensingError
A)Inletwatertemperaturesensorisreportingatemperatureinexcessof104°F.
Normaloperationresumes2minutesafterinletwatertemperaturesensorreports
temperaturesof104°Forless.Thiserrorfunctionsinbothnormalandremote
thermostatmodes.
or
B)Inletwatertemperaturesensorisreportingatemperaturechangeatarate
fasterthan6°Fin60seconds,indicatingapotentiallydamaginglowwaterow
conditon.Normaloperationresumeswhentemperaturesstabilize.Ifthiscondi-
tionisdetected3timesinaonehourperiod,theheaterwilllock-outuntilthe
electricalpoweriscycledoffandbackon.
Sb
Keypadbuttonstuck
closederror
Ifoneofthekeypadbuttonsisclosed(orpressed)formorethan30stheerror
codewillbedisplayedbutthecontrolwillcontinuetofunction.Theerrorcode
willbeclearedwhentheconditioniscorrected.
IF
Ignitionfailureerror Ifthecontrolexceedsthemaximumnumberofignitionretriesorrecyclesthe
heaterwillshutdownandgointolockout.Automaticresetis60minutes.
CE
Communicationerror Ifcommunicationbetweentheignitionboardandthedisplayboardisnotestab-
lishedwithin3sofpower-upanerrorwillbedisplayed.Aftercommunicationis
established,ifitislostfor30s,theerrorwillbedisplayed.Theerrorcodewill
becleareduponavaliddataexchangebetweenboards.
LO
Limitstringopenerror Ifthelimitstringopenstheheatershutsdownandgoesintolockout.Automatic
restartis2minutesaftertheerrorconditioniscorrectedandthelimitstring
closes.Seebelowformoredetail.
EE
EEPROMERROR Anerrorwasdetectedintheignitioncontrolcircuitboard.
Pomona, CA Clemmons, NC Nashville, TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
15
HAYWARD POOL HEATER CERTIFICATE OF LIMITED WARRANTY
Limitedheaterwarranty:
TERMSANDCOVERAGE:Wewarrantourpoolheatertobefreefromdefectsinworkmanshipandmateri-
alsundernormaluseandservice.PursuanttothiswarrantyandsubjecttotheConditionsand
Exceptionsindicatedbelow:
1.Wewillreplace(costoffreight,installation,costoffuel,andservicelaboratusersexpense)with
theprevailingcomparablemodel,or,atouroption,repairanypool/spaheaterthatleaksundernor-
maluseandservicewithinoneyearfromthedateoforiginalinstallationforallusers.
2.Inaddition,wewillreplace(costoffreight,installation,costoffuel,andservicelaboratusers
expense)or,atouroption,repairanypartorpartsofthepool/spaheaterwhichmalfunctionsunder
normaluseandservicewithinoneyearfromthedateoforiginalinstallationforallusers.
LIMITATION ON IMPLIED WARRANTIES:WEARENOTLIABLEFORANYCONSEQUENTIAL
DAMAGESFORBREACHOFANYWRITTENORIMPLIEDWARRANTYOFTHISPRODUCT.Im-
pliedwarranties,includingtheWARRANTYofMERCHANTABILITYandallotherimpliedwarranties
thatmayarisefromcourseofdealingorusageoftradeimposedonthesaleofthisheaterunderlawsofthe
statearelimitedindurationtothetermofone(1)yearforallproductswhenproductsareNOTinstalledand
servicedbyalicensedandqualiedpoolequipmentprofessionalwithallsufcientexperienceinpoolequip-
mentinstallationandmaintenanceandadheringtotherequirementsofthejurisdictionwheretheproductis
installed.
Warrantyextendsindurationtothetermof(2)yearsforallnon-ASMEcertiedproductsandthree(3)years
forallASMEcertiedproductsONLYwhenproductsareinstalledandservicedbyalicenesedandqualied
poolequipmentprofessionalwithsufcientexperienceinpoolequipmentinstallationandmaintenanceand
adheringtotherequirementsofthejurisdictionwheretheproductisinstalled.Therearenowarrantieswhich
extendbeyondthedescriptiononthefacehereof.Weshallnotinanyeventbeheldliableforanyspecial,
indirectorconsequentialdamages.
EXPENSE OF DELIVERY AND INSTALLATION:
Eachpoolheaterorreplacementparttobefurnishedunderthiswarrantyshallbefurnishedatournearest
distributioncenter.Weshallnotpay,norberesponsibleforshippingordeliverychargestotheplaceofinstal-
lation,norforlaborchargesorothercostsofremovalorinstallation.Everydefectiveheaterorpartreplaced
underthiswarrantyshallbecomeourproperty,andassuch,mustbereturnedtoourdistributioncenterwith
transportationchargespaidbytheuser.Anyreplacementpoolheaterfurnishedunderthiswarrantyshallre-
maininwarrantyonlyfortheunexpiredportionofthiswarranty.
CONDITIONS AND EXCEPTIONS:
Thiswarrantyappliesonlytothepool/spaatitsoriginalplaceofinstallationandonlyfortheoriginalowner.
Itdoesnotapplyifthepoolheaterisinstalledinviolationofanyapplicablecodeorordinance,orisnot
installed,operatedandmaintainedinaccordancewithourinstructions,orismisused,damagedbyaccident,
weather,actofGod,freezing,watervoidand/orexcesspressure,alteredordisconnected.Itdoesnotapply
withrespectto:
1.AheaternotequippedwithCertiedC.S.A.limitcontrolsorequivalentpressurereliefvalve.
2.Aheateroperatedwithsettingsinexcessof,and/orwithfuelnotconformingtothoseshownonrat-
ingplate;
3.Aheateronwhichtheserialnumbershavebeenaltered,defaced,orremoved.
4.Leaksarisingfromdefectiveinstallation;
5.Productionofnoise,odors,ordiscolored(rusty,etc.)water;
6.Leakagesubstantiallycontributedtobysediment,limeprecipitateand/orhigherthannormaldis-
solvedsolids(pHabove7.8)inthetank,coppertubes,orwaterways;
7.Leakagecausedsubstantiallycontributedtobycorrosiveelementsintheatmosphere(suchasthe
storageofchlorineorotherchemicals);
Pomona, CA Clemmons, NC Nashville, TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
16
8.Leakagecausedsubstantiallyorcontributedtobycorrosivepoolwaterinanacidcondition(pHbelow7.2);
9.Damagecausedsubstantiallyorcontributedtobyanexternalsourceofenergy;
10.Apool/spaheaterisawatercontainingdevice.Leakageofwaterfromthisdevicecanbeexpected
atsometimeduetomalfunctionorthelimitationsoftheservicelifeofvariouscomponents.
Donotinstallthisproductwheresuchleakagecancausedamage.MANUFACTURERISNOTRESPON-
SIBLEORLIABLEFORANYCOSTSINCURREDBYSUCHDAMAGE.
IN NO CASE ARE WE TO BE HELD LIABLE FOR DAMAGE
TO SURROUNDING AREA OR PROPERTY
CAUSED BY LEAKAGE OR MALFUNCTION.
HOW TO CLAIM UNDER THIS WARRANTY:
Theoriginalowner,upondiscoveringthedefect,mustpresenttheattachedcompletedwarrantyclaimcard
withproofofpurchaseeithertothedealerornotifytheCompanyinwritingateitheraddress:
HAYWARD POOL PRODUCTS, INC.
620 DIVISION ST.
ELIZABETH, NJ 07207
OR
HAYWARD POOL PRODUCTS, INC.
2875 POMONA BOULEVARD
POMONA, CA 91768
Uponreceiptofsuchnoticationweshalldecidewhethertorepairsuchpartsorreplaceanypoolheater,
reservingatalltimestherighttoinspectinordertoverifyanyclaimeddefect.Wealsoreservetherightto
haveourrepresentativesmakeanyinspections,repairs,ortofurnishreplacements.Thiswarrantyisintended
asalegallybindingobligationoftheCompany,enforceableinthecourts.Thiswarrantymaygiveyouspe-
ciclegalrightswhichmayvaryfromstatetostate.
LIMITATION ON LIABILITY:
Allintendedrepresentationshavebeenexpresslysetforthinthisdocument.Thiswarrantymaynotbe
extendedbyoraloranyotheradditionalrepresentations,writtensalesinformation,drawings,orothermal-
function,isstrictlylimitedtorepairorreplacementofthedefectiveheaterorpart,asprovidedhereinand
theCompanyisnotresponsiblehereunderforincidentalorconsequentialorincidentalcostsordamages.
Thecompanyneitherassumes,norauthorizesanypersonorrmtoassumeforus,anyfurtherliabilityor
obligationinconnectionwiththesale,installation,use,maintenance,orexistenceoftheheater.SAFETY
WARNING:Poolheatersareheatproducingappliancesandtoavoiddamageorinjuryintheeventofpos-
sibleoverheatingoftheouterjacket(1)nomaterialsshouldbestoredagainstthejacketand(2)careshould
betakentoavoidunnecessarycontact(especiallybychildren)withthejacket.Whenlightingagasheater,the
lightinginstructionsmustbefollowedexactlytoprevent“ashback”ofexcessgasintheheater.Electronic
ignitionheatersandelectricheatersmusthavethepowershutoffwhenmakingadjustmentsto,servicing,or
comingintocontactwiththeheater.UNDERNOCIRCUMSTANCESSHOULDFLAMMABLEMATERI-
ALS,SUCHASGASOLINEORPAINTTHINNERS,BEUSEDORSTOREDINTHEVICINITYOFTHE
HEATERORINANYLOCATIONFROMWHICHFUMESCOULDREACHTHEHEATER.Foryour
comfort,enjoymentandsafety,pleasereadtheenclosedoperatinginstructionscarefully.
HAYWARD POOL HEATER CERTIFICATE OF LIMITED WARRANTY (CONTINUED)
16
Hayward Pool Products, Inc.
620 Division St.
Elizabeth, NJ 07207
Hayward Pool Products, Inc.
2875 Pomona Boulevard
Pomona, CA 91768
Hayward Pool Products, Inc.
2880 Plymouth Drive
Oakville, Ontario L6H 5R4
Hayward S.A.
Zoming de Jumet
B6040 Jumet, Belgique
© 2004 Hayward Imprimé aux U.S.A.
CERTIFICAT DE GARANTIE LIMITÉE DU RÉCHAUFFEUR DE PISCINE HAYWARD
Ne pas installer ce produit là où ces fuites peuvent causer des dommages. LE FABRICANT N’EST PAS RESPONSABLE POUR
LES DÉPENSES CAUSÉES PAR DE TELS DOMMAGES.
NOUS NE SERONS EN AUCUN CAS TENUS RESPONSABLES
POUR LES DOMMAGES SUBIS PAR LA ZONE OU LA PROPRIÉTÉ
VOISINE ET CAUSÉS PAR LES FUITES OU LES DÉFAILLANCES.
COMMENT DÉPOSER UNE RÉCLAMATION DANS LE CADRE DE CETTE GARANTIE :
Le propriétaire d’origine, lorsqu’il découvre la défaillance, doit présenter la carte de réclamation de garantie remplie avec
justicatif d’achat au concessionnaire ou doit notier la société par écrit à l’une des adresses suivantes :
HAYWARD POOL PRODUCTS, INC.
620 Division St.
Elizabeth, NJ 07207
OU
HAYWARD POOL PRODUCTS, INC.
2875 Pomona Boulevard
Pomona, CA 91768
Sur réception d’une telle notication, nous déciderons de réparer les pièces ou de remplacer le réchauffeur de piscine, en nous
réservant le droit d’inspection à tout moment pour vérier la défaillance objet de la réclamation. Nous nous réservons aussi le droit de
demander à ce que nos représentants effectuent toute inspection ou réparation ou fournissent tout rechange. Cette garantie est conçue
pour obliger légalement la société et être applicable devant les tribunaux. Cette garantie vous donne des droits légaux spéciques qui
peuvent varier d’un état à l’autre.
LIMITATION DE RESPONSABILITÉ :
Toutes les représentations voulues ont été faites explicitement dans ce document. Cette garantie ne peut pas être ampliée
par toute autre représentation additionnelle, orale ou autre, par les informations de vente écrites, par les dessins ou par d’autres
défaillances, elle est strictement limitée à la réparation ou au remplacement du réchauffeur ou de la pièce défectueux, selon les
dispositions des présentes, et la société n’est pas responsable dans le cadre des présentes pour les coûts ou les dommages fortuits ou
consécutifs. La société n’assume, et n’autorise aucune personne ou entreprise à assumer pour elle, aucune responsabilité ou obligation
supplémentaire concernant la vente, l’installation, l’utilisation, la maintenance ou l’existence du réchauffeur. AVERTISSEMENT DE
SÉCURITÉ : Les réchauffeurs de piscine sont des appareils qui dégagent de la chaleur et, pour éviter les dommages ou les blessures
en cas de surchauffe possible de l’enveloppe extérieure, (1) aucun matériau ne doit être remisé contre l’enveloppe, et (2) il faut faire
attention d’éviter tout contact non nécessaire (en particulier par les enfants) avec l’enveloppe. Pour allumer un réchauffeur à gaz, les
instructions d’allumage doivent être suivies pour empêcher le retour de amme de l’excédant de gaz dans le réchauffeur. Il faut couper
l’alimentation des réchauffeurs à allumage électronique et des réchauffeurs électriques pour faire des ajustements, effectuer l’entretien
ou entrer en contact avec le réchauffeur. EN AUCUN CAS LES MATIÈRES INFLAMMABLES, TELLES QUE L’ESSENCE
OU LES DILUANTS, NE DOIVENT ÊTRE UTILISÉES OU ENTREPOSÉES PRÈS DU RÉCHAUFFEUR OU DANS TOUT
ENDROIT À PARTIR DUQUEL LES VAPEURS POURRAIENT ATTEINDRE LE RÉCHAUFFEUR. Pour votre confort, votre
plaisir et votre sécurité, veuillez lire avec soin les instructions d’utilisation ci-jointes.
Pomona, CA Clemmons, NC Nashville, TN
Tél : 908-351-5400 www.haywardpool.com
UTILISEZ UNIQUEMENT DES PIÈCES DE RECHANGE HAYWARD AUTHENTIQUES
15
Garantie limitée du réchauffeur :
CONDITIONS ET COUVERTURE : Nous garantissons que notre réchauffeur de piscine est dépourvu de vices de main d’œuvre et
de matériau dans des conditions normales d’utilisation et d’entretien. En vertu de cette garantie, et sous réserve des conditions et des
exceptions indiquées ci-dessous :
1. Nous remplacerons (les frais d’expédition, d’installation, de combustible et de main d’œuvre de service étant à la charge de
l’utilisateur) avec le modèle prédominant comparable ou, selon notre option, nous réparerons tout réchauffeur de piscine/spa
qui a des fuites dans des conditions normales d’utilisation et d’entretien dans un délai d’un an de la date d’installation initiale
pour tous les utilisateurs.
2. En outre, nous remplacerons (les frais d’expédition, d’installation, de combustible et de main d’œuvre de service étant à la
charge de l’utilisateur) ou, selon notre option, nous réparerons toute pièce ou toutes les pièces du réchauffeur de piscine/spa
qui sont défaillantes dans des conditions normales d’utilisation et d’entretien dans un délai d’un an de la date d’installation
initiale pour tous les utilisateurs.
LIMITATION DES GARANTIES IMPLICITES : NOUS NE SOMMES PAS RESPONSABLES POUR TOUT DOMMAGE
CONSÉCUTIF À LA VIOLATION DE TOUTE GARANTIE ÉCRITE OU IMPLICITE DE CE PRODUIT. Les garanties implicites,
y compris la GARANTIE de VALEUR MARCHANDE, et toutes les autres garanties implicites qui peuvent apparaître dans le
processus de vente ou les usages commerciaux imposés à la vente de ce réchauffeur selon les lois de l’état sont limitées à la durée
d’un (1) an pour tous les utilisateurs. Il n’existe aucune garantie qui se prolonge au-delà de la description des présentes. Nous
n’assumerons en aucun cas une responsabilité quelconque pour tout dommage spécial, indirect ou consécutif.
FRAIS DE LIVRAISON ET D’INSTALLATION :
Chaque réchauffeur de piscine ou pièce de rechange à fournir dans le cadre de cette garantie sera fourni à l’endroit de notre
centre de distribution le plus proche. Nous ne paierons pas, et nous ne serons pas responsables pour payer, les frais d’expédition ou de
livraison au lieu d’installation, ni les frais de main d’œuvre ou autres coûts associés à la dépose ou l’installation. Chaque réchauffeur
ou pièce défectueux remplacé dans le cadre de cette garantie deviendra notre propriété et, en tant que tel, doit être renvoyé à notre
centre de distribution, avec les frais de transport payés par l’utilisateur. Tout réchauffeur de piscine de rechange fourni dans le cadre
de cette garantie restera couvert par la garantie uniquement pour la période de couverture non expirée de cette garantie.
CONDITIONS ET EXCEPTIONS :
Cette garantie concerne uniquement la piscine/le spa à son lieu original d’installation, et seulement pour le propriétaire original.
Elle n’est pas applicable si le réchauffeur de piscine est installé en violation de tout code ou décret applicable, ou n’est pas installé,
utilisé et maintenu conformément à nos instructions, ou est mal utilisé, endommagé par accident, par les intempéries, par un cas de
force majeure, par le gel, par l’absence d’eau et/ou les excès de pression, altéré ou déconnecté. Elle ne s’applique pas à ce qui suit :
1. Un réchauffeur non équipé de contrôles de limite certiés C.S.A. ou d’une soupape de détente de pression équivalente.
2. Un réchauffeur utilisé avec des réglages excédant ceux de la plaque des valeurs nominales, et/ou avec un combustible non
conforme à ces réglages ;
3. Un réchauffeur sur lequel les numéros de série ont été modiés, dégurés ou retirés ;
4. Des fuites dues à une installation défectueuse ;
5. La production de bruit, d’odeur ou d’eau décolorée (rouillée, etc.) ;
6. Les fuites dues essentiellement aux sédiments, aux précipités de chaux et/ou à une concentration de solides dissous supérieure
à la normale (pH supérieur à 7,8) dans le réservoir, les tubes en cuivre ou les canalisations d’eau ;
7. Les fuites dues essentiellement à des éléments corrodants dans l’atmosphère (tels que le stockage du chlore ou d’autres
produits chimiques) ;
8. Les fuites causées ou contribuées essentiellement par l’eau de piscine corrodante dans un état acide (pH inférieur à 7,2) ;
9. Les dommages causés ou contribués essentiellement par une source extérieure d’énergie ;
10. Un réchauffeur de piscine/spa est un dispositif qui contient de l’eau. Les fuites d’eau de ce dispositif peuvent être anticipées à
un moment donné à cause de la défaillance ou des limitations de durée de service des divers composants.
CERTIFICAT DE GARANTIE LIMITÉE DU RÉCHAUFFEUR DE PISCINE HAYWARD
Pomona, CA Clemmons, NC Nashville, TN
Tél : 908-351-5400 www.haywardpool.com
UTILISEZ UNIQUEMENT DES PIÈCES DE RECHANGE HAYWARD AUTHENTIQUES
14
Figure 4 : Codes d’erreur (suite)
IO
Erreur d'allumeur ouvert Si le contrôle n'est pas dans le mode de verrouillage et détecte que le circuit de l'allumeur
est ouvert lorsque la soufante est en marche, le contrôle arrête la soufante et entre
dans le mode de verrouillage. Redémarrage automatique 2 minutes après la correction de
l'erreur.
SF
Erreur de thermistor Une différence de température excessive entre les deux thermistors (5°F ou plus) ou une
condition «hors limite » des deux capteurs (moins de 10°F ou plus de 180°F) conduit au
code d'erreur. Redémarrage automatique 2 minutes après la correction de l'erreur.
HS
Erreur de détection de
température de l’eau
A) Le capteur de température d’arrivée d’eau signale une température supéri-
eure à 40°C (104°F). Le fonctionnement normal reprend 2 minutes après que le
capteur de température d’arrivée d’eau ait signalé des températures de 40°C ou
moins. Cette erreur se produit dans les modes de thermostat normal et à distance.
ou
B) Le capteur de température d’arrivée d’eau signale un changement de tempéra-
ture à un taux plus rapide que 3,33°C (6°F) en 60 secondes, ce qui indique une
condition de débit d’eau faible potentiellement nuisible. Le fonctionnement nor-
mal reprend lorsque les températures se stabilisent. Si cette condition est détec-
tée trois fois dans une période d’une heure, le chauffe-piscine/spa se verrouillera
jusqu’à ce que l’alimentation électrique passe par un cycle complet en fonction/
hors fonction.
Sb
Erreur de bouton de clavier
coincé à l'état enfoncé
Si l'un des boutons du clavier est enfoncé pendant plus de 30 sec, le code d'erreur
s'afche mais le contrôle continue à fonctionner. Le code d'erreur est effacé lorsque la
condition est corrigée.
IF
Erreur d'échec d'allumage Si le contrôle dépasse le nombre maximum de nouveaux essais d'allumage ou de cycle,
le réchauffeur s'arrête et entre dans le mode de verrouillage. Réinitialisation automatique
au bout de 60 minutes.
CE
Erreur de communication Si les communications entre la carte d'allumage et la carte d'afchage ne sont pas
établies dans un délai de 3 sec après la mise sous tension, une erreur est afchée. Après
l'établissement des communications, et si elles sont perdues pendant 30 sec, l'erreur est
afchée. Le code d'erreur est effacé sur échange de données valide entre les cartes.
LO
Erreur de chaîne limite
ouverte
Si la chaîne limite s'ouvre, le réchauffeur s'arrête et entre dans le mode de verrouillage.
Le redémarrage automatique a lieu 2 minutes après la correction de l'erreur et la
fermeture de la chaîne limite. Voir ci-dessous pour de plus amples détails.
EE Erreur de EEPROM Une erreur a été detectée dans la carte de circuit de commande d’allumage.
Code Description Information
Pomona, CA Clemmons, NC Nashville, TN
Tél : 908-351-5400 www.haywardpool.com
UTILISEZ UNIQUEMENT DES PIÈCES DE RECHANGE HAYWARD AUTHENTIQUES
13
CODES D’ERREUR : La gure 4 liste les codes d’erreur qui peuvent être afchés sur le tableau d’afchage du réchauffeur.
Contacter une agence d’entretien qualiée pour obtenir une assistance.
Figure 4: Codes d’erreur
Code Description Information
bD
Faute interne / erreur de
mise sous tension
Lors de l'essai initial d'allumage. La réinitialisation automatique est immédiate une fois
que le relais de la soupape de gaz vérie que les résultats sont acceptables.
bD
Détection d'erreur ON (de
marche) de la soupape à
gaz
Si la soupape est ouverte lorsqu'elle devrait être fermée, le réchauffeur s'arrête et entre
dans le mode de verrouillage. La soufante fonctionne jusqu'à ce que la condition
d'erreur soit corrigée. Redémarrage automatique 2 minutes après la correction de l'erreur.
bD
Détection d'erreur OFF
(d'arrêt) de la soupape à
gaz
Si la soupape est fermée mais une amme est détectée, la soufante fonctionne pendant
5 sec, puis une nouvelle séquence d'allumage commence. Si l'erreur se produit 10
fois pendant une demande de chaleur, le contrôle entre dans le mode de verrouillage.
Réinitialisation automatique au bout de 60 minutes.
bD
Erreur de récupération des
données
Si les données d'entrée de contrôle sont corrompues, le réchauffeur s'arrête et entre dans
le mode de verrouillage.
HF
Erreur de amme présente
avec la soupape à gaz OFF
(arrêtée)
Si la amme est détectée avec la soupape à gaz arrêtée, le contrôle entre dans le mode de
verrouillage. La soufante fonctionne jusqu'à ce que la condition d'erreur soit corrigée.
Une fois corrigée, le contrôle fait marcher la soufante pendant 5 sec, puis redémarre
automatiquement au bout de 2 minutes.
PF
Erreur de câblage de
l'alimentation électrique
Ce code s'afche si la polarité de 120 V est inversée, si une tension basse est détectée,
ou si le chemin de mise à la terre n'est pas sufsant. La réinitialisation est immédiate une
fois que l'erreur est corrigée.
AO
Déecteur d'interrupteur
d'alimentation ouvert
Si l'interrupteur d'alimentation de la soufante ne se ferme pas après le démarrage de la
soufante, le contrôle arrête l'essai d'allumage et entre dans le mode de verrouillage. La
soufante continue à fonctionner. La réinitialisation automatique est immédiate après la
fermeture de l'interrupteur.
AO
Déecteur d'interrupteur de
vérication ouvert lorsqu'il
est anticipé être fermé
Si l'interrupteur de vérication de la soufante s'ouvre subitement pendant le
fonctionnement, le contrôle d'arrête et essaie un ré-allumage. Si l'interrupteur ne se ferme
pas après le démarrage de la soufante, le contrôle entre dans le mode de verrouillage
avec la soufante en marche. La réinitialisation automatique est immédiate après la
correction de l'erreur.
AO
Déecteur d'interrupteur de
vérication ouvert pendant
la post-purge
Si l'interrupteur de vérication de la soufante s'ouvre pendant le cycle de post-purge (le
réchauffeur ne chauffe pas), le contrôle afche le code d'erreur. Le cycle de post-purge
est complété une fois que l'interrupteur de vérication de la soufante se ferme.
AC
Déecteur d'interrupteur de
vérication fermé lorsqu'il
est anticipé être ouvert
Si l'interrupteur de vérication de la soufante est fermé avant le démarrage de la
soufante, le contrôle ne fait pas démarrer la soufante. La réinitialisation automatique
est immédiate lorsque l'interrupteur s'ouvre.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Hayward H150FDP Le manuel du propriétaire

Catégorie
Outils de jardin
Taper
Le manuel du propriétaire

dans d''autres langues