FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE
PART NO. W10133923A PAGE 10 PIÈCE N
o
W10133923A
ELECTRIC DRYER:
1. Unplug dryer or disconnect
power.
2. Remove the toe panel to
access the thermal
components. See Removing
the Toe Panel, page 14.
3. Using an ohmmeter and
referring to the wiring
diagram, measure the
resistance from the red wire
terminal at the thermal
cut-off to the red wire
terminal at the heater.
➔
If the resistance is about
10 Ω, go to step 5.
➔
If an open circuit is
detected, go to step 4.
4. Visually check the wire
connections to the thermal
cut-off, high limit thermostat,
and heater. If connections
look good, check for
continuity across each of
these components.
➔
Replace the heater if it is
electrically open.
➔
Replace both the thermal
cut-off and high limit
thermostat if either one is
electrically open.
5. If no open circuit is
detected, remove the P14
connector, then measure the
resistance between P14-3
(red-white wire) and P14-6
(red-white wire) at the
connector. See figure 18,
page 15 for connector
location; and Accessing &
Removing the Electronic
Assemblies, page 15.
➔
If 5–15 kΩ are measured,
replace the machine control
electronics.
➔
If the resistance is less
than 1 kΩ, replace the
exhaust thermistor.
GAS DRYER:
1. Unplug dryer or disconnect
power.
2. Remove the toe panel to
access the thermal
components. See Removing
the Toe Panel, page 14.
3. Perform TEST #3b, page 11.
If the thermal fuse is OK, go
to step 4.
4. Perform TEST #3c, page 11.
If the thermal cut-off is OK,
go to step 5.
5. Locate the high limit thermo
-
stat. See figure 12, page 9.
Measure the continuity
through it by connecting the
meter probes on the red
wire and blue wire terminals.
➔
If there is an open circuit,
replace the high limit ther
-
mostat and thermal cut-off.
SÉCHEUSE ÉLECTRIQUE :
1. Débrancher la sécheuse ou
déconnecter la source de courant
électrique.
2. Enlever le panneau de plinthe pour
accéder aux composants du système
de chauffage. Voir Dépose du
panneau de plinthe, page 14.
3. Utiliser le schéma de câblage et un
ohmmètre; mesurer la résistance
entre la broche rouge sur le
coupe-circuit thermique et la broche
rouge sur l'élément chauffant.
➔
Si la résistance est d’environ
10
, passer à l’étape 5.
➔
S’il y a un circuit ouvert, passer à
l’étape 4.
4. Inspecter visuellement les
connexions des conducteurs sur le
coupe-circuit thermique, le
thermostat de température maximum
et l’élément chauffant. Si les
connexions sont en bon état,
contrôler la continuité à travers
chacun de ces composants.
➔
Remplacer l’élément chauffant s’il
est affecté par un circuit ouvert.
➔
Si un circuit ouvert affecte le
coupe-circuit thermique ou le
thermostat de température
maximum, remplacer ces deux
composants.
5. S’il n’y a aucun circuit ouvert,
débrancher le connecteur P14 et
mesurer la résistance entre P14-3
(conducteur rouge-blanc) et P14-6
(conducteur rouge-blanc) au
connecteur. Voir figure 18, page 15;
et Modules électroniques – Accès et
dépose, page 15.
➔
Si on mesure une résistance de
5–15 k
, remplacer le module de
commande électronique de la
machine.
➔
Si la résistance est inférieure à
1 k
, remplacer la thermistance du
circuit de décharge.
SÉCHEUSE À GAZ :
1. Débrancher la sécheuse ou
déconnecter la source de courant
électrique.
2. Enlever le panneau de plinthe pour
accéder aux composants du système
de chauffage. Voir Dépose du
panneau de plinthe, page 14.
3. Exécuter le TEST n
o
3b, page 11.
Si le fusible thermique est en bon
état, passer à l’étape 4.
4. Exécuter le TEST n
o
3c, page 11.
Si le coupe-circuit thermique est en
bon état, passer à l’étape 5.
5. Identifier le thermostat de tempéra
-
ture maximum; voir la figure 12, page
9. Contrôler la continuité à travers le
thermostat : connecter l’instrument
sur les broches rouge et bleue.
➔
S’il y a un circuit ouvert, remplacer
le thermostat de température maxi
-
mum et coupe-circuit thermique.
➔
Sinon, passer à l’étape 6.
➔
Otherwise, go to step 6.
6. Perform TEST #3d, page 11.
If this is OK, replace the
machine control electronics.
Heat will not shut off:
1. Unplug dryer or disconnect
power.
2. Access the machine control
electronics. Remove the P14
connector, then measure the
resistance between P14-3
(red-white wire) and P14-6
(red-white wire) at the
connector. See figure 18,
page 15 for connector
location, and Accessing &
Removing the Electronic
Assemblies, page 15.
➔
If 5–15 kΩ are measured,
replace the machine control
electronics.
➔
If the resistance is
greater than 20 kΩ, replace
the exhaust thermistor.
TEST #3a Exhaust
Thermistor
The machine control
electronics monitors the
exhaust temperature using the
exhaust thermistor, and cycles
the heater relay on and off to
maintain the desired
temperature.
Begin with an empty dryer and
a clean lint screen.
1. Plug in dryer or reconnect
power.
2. Start the Timed Dry cycle.
3. If after 60 seconds,
F-22 or
F-23 flashes in the display
and the dryer shuts off, the
thermistor or wire harness is
either open or shorted.
➔
Unplug dryer or
disconnect power.
➔
Check wire connections
at the machine control
electronics and thermistor.
See Accessing & Removing
the Electronic Assemblies,
page 15, and for thermistor
location see figure 12,
page 9.
➔
If wire connections are
good, remove the two wires
from the thermistor and
replace the thermistor.
➔
Plug in dryer or
reconnect power.
6. Exécuter le TEST n
o
3d, page 11.
Si l’électrovanne est en bon état,
remplacer le module de commande
électronique de la machine.
Impossibilité d’arrêt du chauffage :
1. Débrancher la sécheuse ou
déconnecter la source de courant
électrique.
2. Accéder au module de commande
électronique de la machine.
Débrancher le connecteur P14 et
mesurer la résistance entre les
points P14-3 (conducteur
rouge-blanc) et P14-6 (conducteur
rouge-blanc) au connecteur. Voir
figure 18, page 15 pour l’emplace
-
ment des connecteurs, et Modules
électroniques – Accès et dépose,
page 15.
➔
Si on mesure une résistance de
5–15 k
, remplacer le module de
commande électronique de la
machine.
➔
Si la résistance est supérieure à
20 k
, remplacer la thermistance du
circuit de décharge.
TEST N
o
3a Thermistance du
circuit de décharge
Le module de commande électronique
de la machine assure un suivi de la
température dans le circuit de décharge,
au moyen d’une thermistance du circuit
de décharge; l’alimentation intermittente
du relais du circuit de chauffage permet
de maintenir la température désirée.
Travailler sur une sécheuse vide, avec
tamis à peluches propre.
1. Brancher la sécheuse ou
reconnecter la source de courant
électrique.
2. Lancer le programme Timed
Dry/Séchage minuté.
3. Si après 60 secondes on obtient le
clignotement du code
ou
sur l’afficheur alors que la machine
s’arrête, il y a un court-circuit ou
circuit ouvert affectant la
thermistance ou le câblage.
➔
Débrancher la sécheuse ou
déconnecter la source de courant
électrique.
➔
Contrôler les branchements sur
les broches du module de com
-
mande électronique de la machine
et la thermistance. Voir la page 15 -
Modules électroniques – Accès et
dépose, et la figure 12, page 9 pour
l’emplacement de la thermistance.
➔
Si les connexions sont en bon état,
débrancher les deux conducteurs de
la thermistance et remplacer la
thermistance.
➔
Brancher la sécheuse ou
reconnecter la source de courant
électrique.